SlideShare a Scribd company logo
1 of 52
Download to read offline
Power Cable
Low Voltage
Making The Connection
www.kabelindo.co.id
Table Of Contents
TYPE PAGEDESCRIPTION
Cu/PVC 450/750 V (NYA)
Cu/PVC/PVC 300/500 V (NYM)
Cu/PVC 450/750 V (NYAF)
Cu/PVC/PVC 300/500 V (NYMHY)
Cu/PVC/PVC 0.6/1 kV (NYY)
Cu/PVC/PVC 0.6/1 kV Control Cable (NYY)
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Cu/PVC/SFA/PVC 0.6/1 kV Control Cable (NYFGbY)
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Cu/PVC/SWA/PVC 0.6/1 kV Control Cable (NYRGbY)
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Cu/PVC/CTS/PVC 0.6/1 kV Control Cable (NYSY)
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Cu/PVC/CWS/PVC 0.6/1 kV Control Cable (NYCY)
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY)
Cu/PVC/DSTA/PVC 0.6/1 kV Control Cable (NYBY)
Derating Factors
Conversion Table of Conductor Size
Standards
2
3 - 5
6
7
8 - 12
13 - 14
15 - 18
19 - 20
21 - 24
25 - 26
27 - 30
31 - 32
33 - 35
36 - 37
38 - 41
42 - 43
44 - 48
49
50
Copper Conductor Building Wire
Copper Conductor PVC Insulated and PVC Sheathed Indoor Cable
Single Core Flexible Copper Conductor PVC Insulated
Multi Core Flexible Copper Conductor PVC Insulated & PVC Sheathed
Copper Conductor PVC Insulated & PVC Sheathed
non Armoured Power Cable
Copper Conductor PVC Insulated & PVC Sheathed
non Armoured Control Cable
Copper Conductor PVC Insulated & PVC Sheathed
Armoured Power Cable
Copper Conductor PVC Insulated & PVC Sheathed
Armoured Control Cable
Copper Conductor PVC Insulated & PVC Sheathed
Armoured Power Cable
Copper Conductor PVC Insulated & PVC Sheathed
Armoured Control Cable
Copper Conductor PVC Insulated, Copper tape Screened and
PVC Sheathed Power Cable
Copper Conductor PVC Insulated, Copper tape Screened and
PVC Sheathed Cotrol Cable
Copper Conductor PVC Insulated, Concentric Copper wire Screened
and PVC Sheathed Power Cable
Copper Conductor PVC Insulated, Concentric Copper wire Screened
and PVC Sheathed Control Cable
Copper Conductor PVC Insulated & PVC Sheathed
Armoured Power Cable
Copper Conductor PVC Insulated & PVC Sheathed
Armoured Control Cable
sales@kabelindo.co.id 1
Copper Conductor PVC Insulated Building Wire
Cu/PVC 450/750 V (NYA)
Specification :
SPLN 42-1 : 1991
IEC 227
SNI 04-6629 : 3-2006
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 2 - 3 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC) complied with
SPLN 41-2
Identification:
Yellow/Green strip, Light Blue, Black, Yellow, Red colour
Applications:
Permanent installation in conduit or exposed wiring in dry location.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [C] Coil
[D] Drum
Conductor
Nominal
crosssection
area
Nominal
thickness
Insulation
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
in Pipe 0.1
second
Insulation
Min
in Air 0.5
second
1.0
sq.mm mm mm kg/km mm Ohm/km AM.Ohm. A kA kA kA mm
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
19
20
31
33
45
48
65
71
108
175
273
367
523
692
962
1192
1511
1844
2430
3015
3863
3.3
3.4
3.9
4.2
4.4
4.7
4.9
5.4
6.8
8.0
9.8
11
13
15
17
19
21
23.5
26.5
29.5
33.5
1.5 re
1.5 rm
2.5 re
2.5 rm
4 re
4 rm
6 re
6 rm
10 rm
16 rm
25 rm
35 rm
50 rm
70 rm
95 rm
120 rm
150 rm
185 rm
240 rm
300 rm
400 rm
15
15
19
19
25
25
33
33
45
61
83
103
132
165
197
235
-
-
-
-
-
50
50
50
50
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
59
61
70
76
79
85
88
97
122
144
176
198
234
270
306
342
378
423
477
531
603
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
3000/D
3000/D
2000/D
1000/D
1000/D
1000/D
500/D
500/D
500 /D
500 /D
500/D
500/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
46.00
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
S.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
65.05
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.5
67.28
87.28
109.10
145.46
24
24
32
32
42
42
54
54
73
98
129
158
197
245
290
345
390
445
525
605
725
www.kabelindo.co.id2
Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable
Cu/PVC/PVC 300/500 V (NYM)
Specification :
SPLN 42-2 : 1992
IEC 227
SNI : 04-6629.4-2006
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular
stranded according to SPLN 42 - 2 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2
Identification of core Identification of core
Light Blue, Black (SPLN) Ligh Blue, Brown (SNI)
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], White colour
Applications:
Permanent installation in conduit under plaster or exposed wiring
in dry location.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [C] Coil
[D] Drum
Conductor
Nominal
crosssection
area
Nominal
Thickness
Insulation Outer
Sheath
(approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity in air
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
30°C 0.1
second
Insulation
Min
40°C 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
1000/D
1000/D
1000/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3 6 4
5.82
9.09
12 73
16
16
22
22
30
30
39
39
53
71
94
117
19
19
25
25
34
34
44
44
61
82
108
134
50
50
50
50
50
50
50
50
50
40
40
40
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
158
164
173
182
203
210
221
236
326
401
401
448
112
119
145
157
209
227
267
291
453
621
958
1249
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.6
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
8.8
9.1
9.6
10.1
11.3
11.9
12.3
13.1
16
18.1
22.3
24.9
2x1.5 re
2x 1.5 rm
2x2.5 re
2x2.5 rm
2x4 re
2x4 rm
2x6 re
2x6 rm
2x 10 rm
2x 16 rm
2x25 rm
2x35 rm
sales@kabelindo.co.id 3
Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable
Cu/PVC/PVC 300/500 V (NYM)
Specification :
SPLN 42-2 : 1992
IEC 227
SNI : 04-6629.4-2006
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular
stranded according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2
Identification of core (SPLN)
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], White colour
Applications:
Permanent installation in conduit under plaster or exposed wiring
in dry location.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [C] Coil
[D] Drum
No. of cores
Yellow/Green strip, Light Blue, Brown
Yellow/Green strip, Light Blue, Black, Brown
Colour of insulation
Three
Four
No. of cores
System - i
Light Blue, Yellow, Black
Light Blue, Red, Yellow, Black
Yellow/Green strip, Light Blue, Black
Yellow/Green strip, Light Blue, Yellow, Black
System - o
Colour of insulation
Three
Four
Conductor
Nominal
crosssection
area
Nominal
Thickness
Insulation Outer
Sheath
(approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity in air
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
30°C 0.1
second
Insulation
Min
40°C 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
1000/D
1000/D
1000/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3 6 4
5.82
9.09
12 73
16
16
22
22
30
30
39
39
53
71
94
117
19
19
25
25
34
34
44
44
61
82
108
134
50
50
50
50
50
50
50
50
50
40
40
40
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
166
173
182
191
214
227
234
248
306
346
425
475
132
140
175
188
254
274
331
359
562
784
1214
1593
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.6
1.6
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
9.2
9.6
10.1
10.6
11.9
12.6
13
13.8
17
19.2
23.6
26.4
3x1.5 re
3x1.5 rm
3x2.5 re
3x2.5 rm
3x4 re
3x4 rm
3x6 re
3x6 rm
3x10 rm
3x16 rm
3x25 rm
3x35 rm
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
1000/D
1000/D
1000/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3 6 4
5.82
9.09
12 73
16
16
22
22
30
30
39
39
53
71
94
117
19
19
25
25
34
34
44
44
61
82
108
134
50
50
50
50
50
50
50
50
50
40
40
40
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
178
185
196
207
232
245
254
270
333
378
466
520
159
169
214
230
313
338
411
446
701
987
1,530
2,014
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
9.9
10.3
10.9
11.5
12.9
13.6
14.1
15
18.5
21
25.9
28.9
4x1.5 re
4x1.5 rm
4x2.5 re
4x2.5 rm
4x4 re
4x4 rm
4x6 re
4x6 rm
4x10 rm
4x16 rm
4x25 rm
4x35 rm
Identification of core (SNI)
www.kabelindo.co.id4
Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable
Cu/PVC/PVC 300/500 V (NYM)
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with
SPLN 41-2
Identification of core: [SPLN]
Yellow/Green strip, Light Blue, Red, Yellow, Black,
Identification of core: [SNI]
Yellow/Green,Light Blue, Black, Brown and Grey
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], White colour
Applications:
Permanent installation in conduit under plaster or exposed wiring in
dry location.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : (C) Coil
(D) Drum
Conductor
Nominal
crosssection
area
Nominal
Thickness
Insulation Outer
Sheath
(approx)(approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity in air
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
30°C 0.1
second
Insulation
Min
40°C 0.5
second
1.0
second
sq.mm mmmmmm kg/km mm Ohm/km M.Ohm.km AA kAkAkA m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
1000/D
1000/D
1000/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
16
16
22
22
30
30
39
39
53
71
94
117
19
19
25
25
34
34
44
44
61
82
108
134
50
50
50
50
50
50
50
50
50
40
40
40
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
193
200
212
225
252
266
277
295
364
414
509
571
189
201
256
276
377
407
499
540
854
1208
1874
2471
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
10.7
11.1
11.8
12.5
14
14.8
15.4
16.4
20.2
23
28.3
31.7
5x1.5 re
5x1.5 rm
5x2.5 re
5x2.5 rm
5x4 re
5x4 rm
5x6 re
5x6 rm
5x10 rm
5x16 rm
5x25 rm
5x35 rm
Specification :
SPLN 42-2 : 1992
IEC 227
SNI : 04-6629.4-2006
sales@kabelindo.co.id 5
Single Core Flexible Copper Conductor PVC Insulated
Cu/PVC/PVC 450/750 V (NYAF)
Specification :
SPLN 42-3 : 1992
IEC 227
SNI : 04-6629.5-2006
Constructions:
1. Conductor:
Annealed plain copper wires bunch stranded, according to
SPLN 41-1; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with
SPLN 41-2
Identification:
Yellow/Green strip, Light Blue, Black, Yellow, Red colour
Applications:
Used for fixed installation inside appliances, switchgear and
controlgear.
Note : [f] Flexible bunched wire
Packing : [C] Coil
[D] Drum
Conductor
Nominal
thickness
Insulation
Nominal
crosssection
area
No. of wire
and
Diameter
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
in Pipe 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
sq.mm mmmm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
500/D
500/D
500/D
500/D
500/D
500/D
500/D
500/D
500/D
500/D
0.06
0.09
0.12
0.17
0.29
0.46
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.08
0.12
0.16
0.24
0.41
0.65
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.18
0.27
0.36
0.55
0.91
1.45
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.5
67.28
87.28
109.10
-
-
19
24
32
41
53
72
97
128
156
195
243
287
342
386
441
525
605
2.5
7
11
15
20
25
33
45
61
82
102
131
164
205
233
-
-
-
-
50
50
50
50
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
39.0
26.0
19.5
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641
47
50
54
63
76
90
113
133
155
194
216
261
297
351
378
423
468
531
585
10
13
16
23
36
51
73
116
180
275
385
550
750
1000
1240
1550
1900
2450
3025
0.6
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
2.2
2.4
2.6
2.8
3
3.5
4.2
5
6.3
7.4
8.6
10.8
12
14.5
16.5
19.5
21
23.5
26
29.5
32.5
0.5 f
0.75 f
1.0 f
1.5 f
2.5 f
4 f
6 f
10 f
16 f
25 f
35 f
50 f
70 f
95 f
120 f
150 f
185 f
240 f
300 f
16/0.2
24/0.2
32/0.2
30/0.25
50/0.25
56/0.3
84/0.3
84/0.4
126/0.4
196/0.4
278/0.4
398/0.4
360/0.5
475/0.5
608/0.5
760/0.5
925/0.5
1221/0.5
1517/0.5
www.kabelindo.co.id6
Multi-Core Flexible Copper Conductor PVC Insulated & PVC Sheathed
Cu/PVC/PVC 300/500 V (NYMHY)
Specification :
SPLN 42-6 : 1991
IEC 227
SNI : 04-6629.5-2006
Constructions:
1. Conductor:
Annealed plain copper wires bunch stranded, according to
SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41-2
Identification of core [SPLN]
No. of cores
System - i System - O
Colour of insulation
Light Blue, Yellow, Black
-
Yellow/Green strip, Light Blue, BlackThree
Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, BlackFour
Light Blue, Black-Two
Yellow/Green strip, Light Blue, Red, Yellow, BlackFive
Identification of core [SNI]
No. of cores Colour of insulation
Four Yellow/Green strip, Light Blue, Black, Brown
Three Yellow/Green strip, Light Blue, Brown
Two Light Blue, Brown
Five Yellow/Green, Light Blue, Black, Brown, and Grey
3. Outer Sheath:
Extruded Polyvinyl Chloride [PVC] White colour
Applications:
These cables are useful for use in dry or damp locations for medium
duties in domestic premises, kitchens, offices, washing machines,
refrigerators, etc. Can be used for cooking and heating appliances
provided that the cable does not come in contact with the hot parts.
Note : [f] Flexible bunched wire
Packing : [C] Coil
Conductor
Insulation Outer
Sheath
Nominal
cross
section
area
No. of wire
and
Diameter
of wire
Overall
Diameter
(approx)
Weight
of Cable
radius
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity in air
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
30°C 0.1 secInsulation
Min
40°C 0.5 sec 1.0 sec
sq.mm mm mmmm mm mm mm Ohm/km AM.Ohm.km A kA kA kA m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
0.06
0.09
0.12
0.17
0.29
0.46
0.06
0.09
0.12
0.17
0.29
0.46
0.06
0.09
0.12
0.17
0.29
0.46
0.06
0.09
0.12
0.17
0.29
0.46
0.08
0.12
0.16
0.24
0.41
0.65
O.OB
0.12
0.16
0.24
0.41
0.65
0.08
0.12
0.16
0.24
0.41
0.65
O.OB
0.12
0.16
0.24
0.41
0.65
0.18
0.27
0.36
0.55
0.91
1.45
0.18
0.27
0.36
0.55
0.91
1.45
0.18
0.27
0.36
0.55
0.91
1.45
0.18
0.27
0.36
0.55
0.91
1.45
1.8
5.5
9.2
13.8
18.4
25.3
1.8
5.5
9.2
13.8
18.4
25.3
1.8
5.5
9.2
13.B
18.4
25.3
1.8
5.5
9.2
13.8
18.4
25.3
2
6
10
15
20
27.5
2
6
10
15
20
27.5
2
6
10
15
20
27.5
2
6
10
15
20
27.5
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
39
26
19.5
13.3
7.98
4.95
39
26
19.5
13.3
7.98
4.95
39
26
19.5
13.3
7.98
4.95
39
26
19.5
13.3
7.98
4.95
108
117
121
139
169
203
115
122
128
149
184
216
126
133
144
164
202
236
140
149
157
185
223
257
56
56
66
90
140
209
60
77
90
147
190
265
70
96
121
167
237
330
90
116
139
194
291
391
0.8
O.B
0.8
0.9
1.0
1.0
0.8
0.8
0.8
O.B
1.0
1.0
0.8
O.B
O.B
0.9
1.0
1.0
O.B
O.B
0.8
0.9
1.0
1.0
6
6.5
6.7
7.7
9.4
11.3
6.4
6.8
7.1
8.3
10.2
12
7
7.4
B
9.1
11.2
13.1
7.B
B.3
8.7
10.3
12.4
14.3
2 x 0.5 f
2 x 0.75 f
2 x 1.0 f
2 x 1.5 f
2 x 2.5 f
2 x 4 f
3 x 0.5 f
3 x 0.75 f
3 x 1.0 f
3 x 1.5 f
3 x 2.5 f
3 x 4 f
4 x 0.5 f
4 x 0.75 f
4 x 1.0 f
4 x 1.5 f
4 x 2.5 f
4 x 4 f
5 x 0.5 f
5 x 0.75 f
5 x 1.0 f
5 x 1.5 f
5 x 2.5 f
5 x 4 f
16/0.2
24/0.2
32/0.2
30/0.25
50/0.25
56/0.3
16/0.2
24/0.2
32/0.2
30/0.25
50/0.25
56/0.3
16/0.2
24/0.2
32/0.2
30/0.25
50/0.25
56/0.3
16/0.2
24/0.2
32/0.2
30/0.25
50/0.25
56/0.3
0.6
0.6
0.6
0.7
0.8
O.B
0.6
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.6
0.7
0.8
0.8
0.6
0.6
0.6
0.7
0.8
0.8
Nominal thickness
sales@kabelindo.co.id 7
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN
41- 2: IEC 60502-1
Identification of core
Light Blue
3. Outer Sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request.
Applications:
Indoor and outdoor induct installation or of laying in the ground
where not sustain mechanical damage.
Note : [re] round solid conductor
[rm] Circular stranded conductor
Packing : [D] Drum
No. of cores
and cross
section area
Nominal
Thickness
Insulation Outer
Sheath (approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
In Ground 0.1
second
Insulation
Min
In Air 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
46.00
57.50
72.45
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
65.05
81.32
102.46
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
145.46
181.83
229.11
26
26
35
35
46
46
58
58
80
105
140
175
215
270
335
390
445
510
620
710
850
1000
1195
33
33
45
45
58
58
74
74
98
129
169
210
250
310
375
425
480
550
640
730
855
990
1126
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
104
108
112
117
128
133
137
144
158
178
209
229
257
288
333
360
400
443
499
553
616
686
763
50
52
63
67
87
92
110
117
163
227
336
437
562
768
1049
1280
1275
1959
2538
3157
3995
5075
6449
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.3
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8
5.8
6
6.2
6.5
7.1
7.4
7.6
8
8.8
9.9
11.6
12.7
14.3
16
18.5
20
22.2
24.6
27.7
30.7
34.2
38.1
42.4
1 x 1.5 re
1 x 1.5 rm
1 x 2.5 re
1 x 2.5 rm
1 x 4 re
1 x 4 rm
1 x 6 re
1 x 6 rm
1 x 10 rm
1 x 16 rm
1 x 25 rm
1 x 35 rm
1 x50 rm
1 x 70 rm
1 x 95 rm
1 x 120 rm
1 x 150 rm
1 x 185 rm
1 x 240 rm
1 x 300 rm
1 x 400 rm
1 x 500 rm
1 x 630 rm
www.kabelindo.co.id8
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN
41- 2: IEC 60502-1
Identification of core (SPLN)
Light Blue, Black
(SNI IEC)
Light Blue, Brown
3. Inner covering / filler :
Extruded Polyvinyl Chloride (PVC) Black colour
4. Outer Sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or
special flame retardant. PVC sheath can be provided on request.
Applications:
Indoor and outdoor induct installation or of laying in the ground where not
sustain mechanical damage.
Note : [re] round solid conductor
[rm] Circular stranded conductor
Packing : [D] Drum
No. of cores
and cross
section area
Nominal Thickness
Insulation Outer
Sheath (approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
In Ground 0.1
second
Insulation
Min
In Air 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
500/D
500/D
500/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15A5
19.52
24.40
30.09
39 03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
21
21
29
29
38
38
48
48
66
90
120
150
180
230
275
320
379
430
510
590
27
27
36
36
47
47
59
59
78
102
134
160
187
230
280
320
355
409
472
525
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
194
200
209
218
239
250
257
272
302
340
401
441
499
565
655
715
787
875
992
1,094
159
168
196
209
269
289
333
359
485
657
959
1224
4578
2131
2905
3531
4321
5368
6964
8605
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2
2.1
2.2
2.4
2.6
2.7
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
10.8
11.1
11.6
12.1
13.3
13.9
14.3
15.1
16.8
18.9
22.3
24.5
27.7
31.4
36.4
39.7
43.7
48.6
55.1
60.8
2x1.5 re
2x1.5 rm
2x2.5 re
2x2.5 rm
2x4 re
2x4 rm
2x6 re
2x6 rm
2x10 rm
2x16 rm
2x25 rm
2x35 rm
2x50 rm
2x70 rm
2x95 rm
2x120 rm
2x150 rm
2x185 rm
2x240 rm
2x300 rm
sales@kabelindo.co.id 9
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
or sector shaped according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN
41- 2: IEC 60502-1
Identification of core : (SPLN)
Identification of core : [SNI]
Yellow/Green, Light Blue, Brown.
3. Inner covering / filler :
Extruded Polyvinyl Chloride (PVC) Black colour
4. Outer Sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/
or special flame retardant. PVC sheath can be provided on request.
Applications:
Indoor and outdoor induct installation or of laying in the ground where
not sustain mechanical damage.
Note : [re] round solid conductor
[rm] Circular stranded conductor
(sm) sector shaped conductor
Packing : [D] Drum
System - i System - o
Colour of insulation
Light Blue, Yellow, BlackYellow/Green strip, Light Blue, Black
No. of cores
and cross
section area
Nominal
Thickness
Insulation Outer
Sheath (approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
In Ground 0.1
second
Insulation
Min
In Air 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/0
500/D
500/D
500/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
18
18
25
25
34
34
44
44
60
80
105
130
160
200
245
285
325
370
435
600
24
24
32
32
41
41
52
52
69
89
116
138
165
205
245
285
315
355
415
535
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
202
209
218
227
252
263
272
286
320
360
425
468
455
515
589
639
706
788
887
990
181
191
229
245
319
342
401
433
596
822
1213
15.65
1898
2580
3485
4312
5300
6478
8491
10652
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2
2.1
2.2
2.3
2.5
2.7
3.1
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
11.2
11.6
12.1
12.6
14
14.6
15.1
15.9
17.8
20
23.6
26
25.3
28.6
32.7
35.5
39.2
43.8
49.3
55
3 x 1.5 re
3 x 1.5 rm
3 x 2.5 re
3 x 2.5 rm
3 x 4 re
3 x 4 rm
3 x 6 re
3 x 6 rm
3 x 10 rm
3 x 16 rm
3 x 25 rm
3 x 35 rm
3 x 50 sm
3 x 70 sm
3 x 95 sm
3 x 120 sm
3 x 150 sm
3 x 185 sm
3 x 240 sm
3 x 300 sm
www.kabelindo.co.id10
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shaped according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41- 2:
IEC 60502-1
Identification of core : (SPLN)
Identification Core : (SNI IEC)
Yellow/Green Strip, Light Blue, Brown
3. Inner covering / filler :
Extruded Polyvinyl Chloride (PVC) Black colour
4. Outer Sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or
special flame retardant. PVC sheath can be provided on request.
Applications:
Indoor and outdoor induct installation or of laying in the ground where not
sustain mechanical damage.
Note : [re] round solid conductor
[rm] Circular stranded conductor
(sm) sector shaped conductor
Packing : [D] Drum
System - i System - 0
Colour of insulation
Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, Black
No. of cores
and cross
section area
Nominal Thickness
Insulation Outer
Sheath
(approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
In Ground 0.1
second
Insulation
Min
In Air 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
500/D
500/D
500/D
0.17
0.17
0.29
0.29
0.46
0A6
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
18
18
25
25
34
34
44
44
60
80
105
130
160
200
245
285
325
370
435
500
24
24
32
32
41
41
52
52
69
89
116
138
165
205
245
285
315
355
415
465
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
216
223
234
245
272
284
293
310
349
392
466
515
540
614
697
767
833
940
1,053
1,177
213
224
273
292
385
413
490
527
743
1035
1541
1999
2498
3374
4536
5676
6910
8596
11087
13549
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.2
2.3
2.5
2.7
2.9
3.1
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
12
12.4
13
13.6
15.1
15.8
16.3
17.2
21
24
28
30
32
36
40
44
49
53
60
66
4 x 1.5 re
4 x 1.5 rm
4 x 2.5 re
4 x 2.5 rm
4 x 4 re
4 x 4 rm
4 x 6 re
4 x 6 rm
4 x 10 rm
4 x 16 rm
4 x 25 rm
4 x 35 rm
4 x 50 sm
4 x 70 sm
4 x 95 sm
4 x 120 sm
4 x 150 sm
4 x 185 sm
4 x 240 sm
4 x 300 sm
sales@kabelindo.co.id 11
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC) complied with SPLN
41-2 : IEC 60502-1
Identification of core : (SPLN)
Yellow/Green strip, Light Blue, Red, Yellow, Black
(SNI IEC) :
Yellow/Green strip, Light Blue, Black, Brown, Grey.
3. Inner covering / filler
Extruded Polyvinyl Chloride (PVC) Black colour
4. Outer sheath
Extruded Polyvinyl Chloride (PVC) Black colour, Anti termite
and / or special flame retardant, PVC sheath can be provided
on request.
Applications:
Indoor and outdoor induct installation or of laying in the ground
where not sustain mechanical damage.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
No. of cores
and cross
section area
Nominal Thickness
Insulation Outer
Sheath
(approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
In Ground 0.1
second
Insulation
Min
In Air 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
18
18
25
25
34
34
44
44
60
80
105
130
160
24
24
32
32
41
41
52
52
69
89
116
138
165
50
50
50
50
50
50
50
50
50
40
40
40
30
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
230
239
252
263
293
308
319
335
380
428
509
567
655
255
268
329
352
470
505
602
650
912
1279
1914
2505
3273
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
12.8
13.3
14
14.6
16.3
17.1
17.7
18.6
21.1
23.8
28.3
31.5
36.4
5 x 1.5 re
5 x 1.5 rm
5 x 2.5 re
5 x 2.5 rm
5 x 4 re
5 x 4 rm
5 x 6 re
5 x 6 rm
5 x 10 rm
5 x 16 rm
5 x 25 rm
5 x 35 rm
5 x 50 rm
www.kabelindo.co.id12
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Control Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core (SPLN)
(SNI IEC): Black, with White Number
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
special flame retardant. PVC sheath can be provided on request
Applications:
Indoor and outdoor induct : installation or of laying in the ground where
not sustain mechanical damage.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : (D) Drum
System - i System - 0
Colour of insulation
Black with White numberYellow/Green strip, Black with White number
No. of cores
and cross
section area
Nominal Thickness
Insulation Outer
Sheath (approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
In Ground 0.1
second
Insulation
Min
In Air 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
13
13
12
12
12
12
11
11
11
11
10
10
9
9
9
9
8
8
8
8
8
8
8
8
8
8
17
17
16
16
15
15
14
14
13
13
12
12
12
12
11
11
11
11
11
11
11
11
11
11
11
11
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
261
270
279
288
313
326
322
335
337
351
351
365
367
383
385
401
421
439
443
463
491
513
576
601
594
623
324
341
362
381
434
458
480
506
542
572
599
632
670
707
728
768
821
866
970
1024
1226
1294
1585
1673
1815
1916
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.0
2.0
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
14.5
15
15.5
16
17.4
18.1
17.9
18.6
18.7
19.5
19.5
20.3
20.4
21.3
21.4
22.3
23.4
24.4
24.6
25.7
27.3
28.5
32
33.4
33
34.6
7x1.5 re
7x1.5 rm
8x1.5 re
8x1.5 rm
10x1.5 re
10x1.5 rm
12x1.5 re
12x1.5 rm
14x1.5 re
14x1.5 rm
16x1.5 re
16x1.5 rm
19x1.5 re
19x1.5 rm
21x1.5 re
21x1.5 rm
24x1.5 re
24x1.5 rm
30x1.5 re
30x1.5 rm
40x1.5 re
40x1.5 rm
52x1.5 re
52x1.5 rm
61x1.5 re
61x1.5 rm
3. Inner Covering / filler:
sales@kabelindo.co.id 13
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Control Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2 : IEC 60502-1
Identification of core (SPLN)
(SNI IEC): Black, with White Number
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
Applications:
Indoor and outdoor induct : installation or of laying in the
ground where not sustain mechanical damage.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : (D) Drum
No. of cores
and cross
section area
Nominal Thickness
Insulation Outer
Sheath (approx) (approx)
Overall
Diameter
Weight
of Cable
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor In Ground 0.1
second
Insulation In Air 0.5
second
1.0
second
sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
21
21
18
18
17
17
16
16
15
15
14
14
13
13
12
12
11
11
11
11
11
11
11
11
11
11
26
26
23
23
21
21
20
20
18
18
17
17
17
17
16
16
15
15
14
14
14
14
14
14
14
14
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
284
297
304
319
344
362
355
373
369
389
387
407
405
425
425
448
466
491
491
518
549
581
644
682
666
704
421
450
471
505
570
611
637
682
724
777
804
863
907
974
989
1062
1118
1200
1335
1433
1718
1846
2220
2384
2552
2741
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.0
2.0
2.1
2.1
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
15.8
16.5
16.9
17.7
19.1
20.1
19.7
20.7
20.5
21.6
21.5
22.6
22.5
23.6
23.6
24.9
25.9
27.3
27.3
28.8
30.5
32.3
35.8
37.9
37
39.1
7x2.5 re
7x2.5 rm
8x2.5 re
8x2.5 rm
10x2.5 re
10x2.5 rm
12x2.5 re
12x2.5 rm
14x2.5 re
14x2.5 rm
16x2.5 re
16x2.5rm
19x2.5 re
19x2.5 rm
21x2.5 re
21x2.5 rm
24x2.5 re
24x2.5 rm
30x2.5 re
30x2.5 rm
40x2.5 re
40x2.5 rm
52x2.5 re
52x2.5 rm
61x2.5 re
61x2.5 rm
4. Outer sheath:
System - i System - 0
Colour of insulation
Black with White numberYellow/Green strip, Black with White number
www.kabelindo.co.id14
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 4 1 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core (SPLN)
Light Blue, Black
( SNI IEC )
Light Blue, Brown.
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Armour :
A layer of galvanized flat steel wires with a counter helix layer of
galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/
or special flame retardant, PVC sheath can be provided on request.
Applications:
For general purpose power distribution in dry or wet location, best
suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Armour
Flat
Steel
Size
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
9.09
12.73
18.18
25.46
34.55
43.84
54.55
67.28
87.28
109.10
120
150
180
230
275
320
379
430
510
590
134
160
187
230
280
320
355
409
472
525
40
40
30
30
30
30
20
20
20
20
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
448
448
549
621
706
765
844
932
1.044
1.154
1383
1709
2170
2846
3702
4423
5347
6501
8231
10081
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.5
2.7
2.8
24.9
27.1
30.5
34.5
39.2
42.5
46.9
51.8
58
64.1
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2x25 rm
2x 35 rm
2x50 rm
2x70 rm
2x95 rm
2x120rm
2x150rm
2x185rm
2x240rm
2x300rm
sales@kabelindo.co.id 15
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60902-1 : 2009
4. Armour :
A layer of galvanized flat steel wires with a counter helix layer
of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
[sm] sector shaped conductor
Packing : [D] Drum
System - i System - 0
Colour of insulation
Light Blue, Yellow, BlackYellow/Green strip, Light Blue, Black
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core (SPLN)
( SNI IEC )
Yellow/Green Strip, Light Blue, Brown.
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
Armour
Flat
Steel
Size
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor in Ground 0.1
second
Insulation in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
80
105
130
160
200
245
285
325
370
435
500
89
116
138
165
205
245
285
315
355
415
465
40
40
40
30
30
30
30
20
20
20
20
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
407
472
515
506
563
641
691
760
842
941
1.033
1010
1695
2084
2403
3112
4151
5041
6121
7377
9536
11717
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.4
2.6
2.8
3.0
22.6
26.2
28.6
28.1
31.3
35.6
38.4
42.2
46.8
52.3
57.4
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
3 x16 rm
3 x 25 rm
3 x 35 rm
3 x 50 sm
3 x 70 sm
3 x 95 sm
3 x120 sm
3 x150 sm
3 x185 sm
3 x 240 sm
3 x 300 sm
www.kabelindo.co.id16
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core : (SPLN)
( SNI IEC ) Yellow/Green Strip, Light Blue, Black, Brown.
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Armour :
A layer of galvanized flat steel wires with a counter helix layer
of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
[sm] sector shaped conductor
Packing : [D] Drum
System - i System - 0
Colour of insulation
Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, Black
Armour
Flat
Steel
Size
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Short Circuit Current
Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
500/D
500/D
250/D
250/D
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
1.63
2.60
48.79
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
80
80
105
130
160
200
245
285
325
370
435
500
69
89
116
138
165
205
245
285
315
355
415
465
50
40
40
40
30
30
30
30
20
20
20
20
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
349
392
466
515
541
614
697
767
833
940
1.053
1.177
1101
1455
2093
2602
3080
4093
5370
6563
7938
9756
12409
15104
1.8
1.8
1.8
1.9
2.0
2.1
2.3
2.4
2.6
2.8
3.0
3.2
23
26
30
33
35
38
43
47
51
56
62
68
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
4 x10 rm
4 x 16 rm
4 x 25 rm
4 x 35 rm
4 x 50 sm
4 x 70 sm
4 x 95 sm
4 x120 sm
4 x150 sm
4 x 185 sm
4 x 240 sm
4 x 300 sm
sales@kabelindo.co.id 17
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2 : IEC 60502-1
Identification of core : (SPLN)
Yellow/Green Strip, Light Blue, Red, Yellow, Black.
( SNI IEC )
Yellow/Green Strip, Light Blue, Black, Brown, Grey.
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Armour :
A layer of galvanized flat steel wires with a counter helix layer
of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Armour
Flat
Steel
Size
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/ mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1.15
1.84
2.88
4.03
5.75
1.63
2.60
4.07
5.69
8.13
3.64
5.82
9.09
12.73
18.18
60
80
105
130
160
69
89
116
138
165
50
40
40
40
30
1.83
1.15
0.727
0.524
0.387
434
482
563
625
715
1323
1750
2519
3158
4117
1.8
1.8
1.9
2.0
2.1
24.1
26.8
31.3
34.7
39.7
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
1.0
1.0
1.2
1.2
1.4
5 x10 rm
5 x 16 rm
5 x 25 rm
5 x 35 rm
5 x 50 sm
www.kabelindo.co.id18
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
4. Armour :
A layer of galvanized flat steel wires with a counter helix layer
of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided
on request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Armour
Flat
Steel
Size
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
13
13
12
12
11
11
11
11
10
10
10
10
9
9
9
9
9
8
8
8
8
9
8
8
8
8
17
17
16
16
15
15
14
14
13
13
12
12
12
12
11
11
11
11
11
11
11
11
11
11
11
11
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
335
346
355
365
391
407
414
428
432
445
450
461
468
479
486
499
508
527
540
565
607
634
677
707
711
743
727
777
792
848
929
997
1117
1199
1197
1287
1310
1382
1391
1504
1496
1611
1629
1766
1857
2020
2420
2635
2932
3190
3215
3518
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.8
1.8
1.8
1.8
1.9
1.8
1.8
1.8
1.8
1.9
1.8
1.8
1.8
1.9
1.9
2.0
2.0
2.1
2.1
18.6
19.2
19.7
20.3
21.7
22.6
23
23.8
24
24.7
25
25.6
26
26.6
27
27.7
28.2
29.3
30
31.4
33.7
35.2
37.6
39.3
39.5
41.3
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
440.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
7x1.5 re
7x1.5 rm
8x1.5 re
8x1.5 rm
10x1.5 re
10x1.5 rm
12x1.5 re
12x1.5 rm
14x1.5 re
14x1.5 rm
16x1.5 re
16x1.5 rm
19x1.5 re
19x1.5 rm
21x1.5 re
21x1.5 rm
24x1.5 re
24x1.5 rm
30x1.5 re
30x1.5 rm
40x1.5 re
40x1.5 rm
52x1.5 re
52x1.5 rm
61x1.5 re
61x1.5 rm
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2 : IEC 60502-1
Identification of core : (SPLN)
( SNI IEC ) Black with White number
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
Colour of insulation
System - i System - 0
Black with White numberYellow/Green strip, Black with White number
sales@kabelindo.co.id 19
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
4. Armour :
A layer of galvanized flat steel wires with a counter helix layer
of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
System - i System - 0
Colour of insulation
Black with White numberYellow/Green strip, Black with White number
Armour
Flat
Steel
Size
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
21
21
18
18
17
17
16
16
15
15
14
14
13
13
12
12
11
11
11
11
11
11
11
11
11
11
26
26
23
23
21
21
20
20
18
18
17
17
17
17
16
16
15
15
14
14
14
14
14
14
14
14
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
335
371
378
392
432
454
443
463
457
481
484
499
495
520
515
544
547
574
585
639
671
711
749
778
790
833
848
918
928
1007
1228
1332
1317
1431
1421
1548
1561
1671
1675
1833
1800
1973
1980
2173
2280
2823
3167
3389
3704
4002
4121
4970
1.8
1.8
1.B
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.0
2.0
2.1
2.1
2.2
2.2
19.7
20.6
21
21.8
24
25.2
24.6
25.7
25.4
26.7
26.9
27.7
27.5
28.9
28.6
30.2
30.4
31.9
32.5
35.5
37.3
39.5
41.6
43.2
43.9
46.3
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
440.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
7x2.5 re
7x2.5 rm
8x2.5 re
8x2.5 rm
10x2.5 re
10x2.5 rm
12x2.5 re
12x2.5 rm
14;2.5 re
14x2.5 rm
16x2.5 re
16x2.5 rm
19x2.5 re
19x2.5 rm
21x2.5 re
21x2.5 rm
24x2.5 re
24x2.5 rm
30x2.5 re
30x2.5 rm
40x2.5 re
40x2.5 rm
52x2.5 re
52x2.5 rm
61x2.5 re
61x2.5 rm
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2 : IEC 60502-1
(SNI IEC)
Black with White number
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
www.kabelindo.co.id20
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core (SPLN)
Light Blue, Black
( SNI IEC )
Light Blue, Brown
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Armour
Round
Steel
Wire
Diameter
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.28
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.45
67.28
8728
109.10
21
21
29
29
38
38
48
48
66
90
120
150
180
230
275
320
375
430
510
590
27
27
36
36
47
47
59
59
78
102
134
160
187
230
280
320
355
409
472
525
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
250
257
263
274
295
306
324
340
374
421
479
520
605
662
760
837
911
1,004
1,120
1,233
374
375
406
430
503
536
674
734
908
1296
1688
2030
2812
3430
4470
5648
6650
8007
9952
11918
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.5
2.7
2.8
13.9
14.3
14.6
15.2
16.4
17
18
18.9
20.8
23.4
26.6
2E9
33.6
36.8
42.2
46.5
50.6
55.8
62.2
58.5
0.9
0.9
0.9
0.9
0.9
02
125
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
0.8
0.8
0.8
as
in
10
10
1.0
1.0
in
12
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2x1.5 re
2x1.5 rm
2x2.5 re
2x2.5 rm
2x4 re
2x4 rrn
2x6 re
2x6 rm
2x10 rm
2x16 rm
2x25 rm
2x35 rm
2x50 rm
2x70 rm
2x95 rm
2x120 rm
2x150 rm
2x185 rm
2x240 rm
2x300 rm
sales@kabelindo.co.id 21
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core : (SPLN)
(SNI IEC)
Yellow/Green Strip, Light Blue,Brown.
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
(sm) sector shaped conductor
Packing : [D] Drum
System - i System - o
Colour of insulation
Light Blue, Yellow, BlackYellow/Green strip, Light Blue, Brown
Armour
Flat
Steel
Size
Thickness
of
Insulation
No. of
cores
and cross
section
Thickness
of outer
sheath
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
1128
15.45
19.52
24.40
30.09
39 03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.45
67.28
87.28
109.10
18
18
25
25
34
34
44
44
60
80
105
130
160
200
245
285
325
370
435
500
24
24
32
32
41
41
52
52
69
89
116
138
165
205
245
285
315
355
415
465
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
257
266
274
284
320
333
338
355
392
441
506
369
589
661
738
787
880
945
1,042
1,124
390
410
451
479
655
699
762
819
1044
1416
1894
2321
2784
3806
4882
5853
7407
8774
11036
13137
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.4
2.6
2.8
3.0
14.3
14.8
15.2
15.8
17.8
18.5
18.8
19.7
21.8
24.5
28.1
30.5
32.7
36.7
41
43.7
48.9
52.5
57.9
62.47
0.9
0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
3x1.5 re
3x1.5 rm
3x2.5 re
3x2.5 rm
3x4 re
3x4 rm
3x6 re
3x6 rm
3x10 rm
3x16 rm
3x25 rm
3x35 rm
3x50 sm
3x70 sm
3x95 sm
3x120 sm
3x150 sm
3x185 sm
3x240 sm
3x300 sm
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Annealed plain copper round solid or round circular stranded
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape.
5. Outer sheath:
www.kabelindo.co.id22
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
(sm) sector shaped conductor
Packing : [D] Drum
System - i System - o
Colour of insulation
Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, Black
Armour
Round
Steel
Wire
Diameter
(nom)
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
area
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx)
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0A6
0A6
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.45
67.28
87.28
109.10
18
18
25
25
34
34
44
44
60
80
105
130
160
200
245
285
325
370
435
500
24
24
32
32
41
41
52
52
69
89
116
138
165
205
245
285
315
355
415
465
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
274
281
288
301
338
355
374
378
432
473
547
592
610
697
790
868
945
1,030
1,157
1,305
433
455
515
538
740
790
870
925
1317
1548
2241
2933
2934
4148
5489
7163
8637
10354
13347
16702
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.3
2.4
2.6
2.8
3.0
3.2
15.2
15.6
16
16.7
18.8
19.7
20.8
21
24
26.3
30A
32.9
33.9
38.7
43.9
48.2
52.5
57.2
64.3
72.5
0.9
0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
4x1.5 re
4x1.5 rm
4x2.5 re
4x2.5 rm
4x4 re
4x4 rm
4x6 re
4x6 rm
4x10 rm
4x16 rm
4x25 rm
4x35 rm
4x50 sm
4x70 sm
4x95 sm
4x120 sm
4x150 sm
4x185 sm
4x240 sm
4x300 sm
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core : (SPLN)
(SNI IEC) Yellow/Green Strip, Light Blue, Black, Brown.
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
sales@kabelindo.co.id 23
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core : (SPLN)
Yellow/Green Strip, Light Blue, Red, Yellow, Black
( SNI IEC )
Yellow/Green Strip, Light Blue, Black, Brown, Grey
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape.
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For general purpose power distribution in dry or wet location,
best suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Armour
Round
Steel
Wire
Diameter
(nom)
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx)
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.96
4.03
5.75
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.15
5.69
8.13
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
18
18
25
25
34
34
44
44
60
80
105
130
160
24
24
32
32
41
41
52
52
69
89
116
138
165
50
50
50
50
50
50
50
50
50
40
40
40
30
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
288
297
319
333
360
378
385
405
463
509
598
673
774
484
509
647
687
839
897
996
1069
1527
1928
2641
3520
4921
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.1
16
16.5
17.7
18.5
20
21
21.4
22.5
25.7
28.3
33.2
37.4
43
0.9
0.9
0.9
1.25
1.25
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1A
5x1.5 re
5x1.5 rm
5x2.5 re
5x2.5 rm
5x4 re
5x4 rm
5x6 re
5x6 rm
5x10 rm
5x16 rm
5x25 rm
5x35 rm
5x50 rm
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Annealed plain copper round solid or round circular stranded
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape.
5. Outer sheath:
www.kabelindo.co.id24
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
System - i System - 0
Colour of insulation
Black with White numberYellow/Green strip, Black with White number
4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
special flame retardant, PVC sheath can be provided on request.
Applications:
For general purpose power distribution in dry or wet location, best
suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Armour
Round
Steel
Wire
Diameter
(nom)
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
area
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx)
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
13
13
12
12
11
11
11
11
10
10
10
10
9
9
9
9
8
8
8
8
8
8
8
8
8
8
17
17
16
16
15
15
14
14
13
13
12
12
12
12
11
11
11
11
11
11
11
11
11
11
11
11
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
335
346
355
365
391
407
414
428
432
445
450
461
468
479
486
499
508
527
540
565
607
634
677
707
711
743
727
777
792
848
929
997
1117
1199
1197
1287
1310
1382
1391
1504
1496
1611
1629
1766
1857
2020
2420
2635
2932
3190
3215
3518
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.1
2.1
2.1
2.1
18.6
19.2
19.7
20.3
21.7
22.6
23
23.8
24
24.7
25
25.6
26
26.6
27
27.7
28.2
29.3
30
31.4
33.7
35.2
37.6
39.3
39.5
41.3
1.25
1.25
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
7x1.5 re
7x1.5 rm
8x1.5 re
8x1.5 rm
10x1.5 re
10x1.5 rm
12x1.5 re
12x1.5 rm
14x1.5 re
14x1.5 rm
16x1.5 re
16x1.5 rm
19x1.5 re
19x1.5 rm
21x1.5 re
21x1.5 rm
24x1.5 re
24x1.5 rm
30x1.5 re
30x1.5 rm
40x1.5 re
40x1.5 rm
52x1.5 re
52x1.5 rm
61x1.5 re
61x1.5 rm
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
4. Armour :4. Armour :
A layer of galvanized round steel wires with a counter helix
layer of galvanized steel tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
special flame retardant, PVC sheath can be provided on request.
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core (SPLN)
(SNI IEC) : Black with White number
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
sales@kabelindo.co.id 25
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Armour
Round
Steel
Wire
Diameter
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor in Ground 0.1
second
Insulation in Air 0.5
second
1.0
second
mmmmsq.mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
21
21
18
18
17
17
16
16
15
15
14
14
13
13
12
12
11
11
11
11
11
11
11
11
11
11
26
26
23
23
21
21
20
20
18
18
17
17
17
17
16
16
15
15
14
14
14
14
14
14
14
14
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
335
371
378
392
432
454
443
463
457
481
484
499
495
520
515
544
547
574
585
639
671
711
749
778
790
833
848
918
928
1007
1228
1332
1317
1431
1421
1548
1561
1671
1675
1833
1800
1973
1980
2173
2280
2823
3167
3389
3704
4002
4121
4970
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
1.9
1.9
2.1
2.1
2.2
2.2
2.3
2.3
19.7
20.6
21
21.8
24
25.2
24.6
25.7
25.4
26.7
26.9
27.7
27.5
28.9
28.6
30.2
30.4
31.9
32.5
35.5
37.3
39.5
41.6
43.2
43.9
46.3
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
7x2.5 re
7x2.5 rm
8x2.5 re
8x2.5 rm
10x2.5 re
10x2.5 rm
12x2.5 re
12x2.5 rm
14x2.5 re
14x2.5 rm
16x2.5 re
16x2.5 rm
19x2.5 re
19x2.5 rm
21x2.5 re
21x2.5 rm
24x2.5 re
24x2.5 rm
30x2.5 re
30x2.5 rm
40x2.5 re
40x2.5 rm
52x2.5 re
52x2.5 rm
61x2.5 re
61x2.5 rm
4. Armour :
A layer of galvanized round steel wires with a counter helix layer of
galvanized steel tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/
or special flame retardant, PVC sheath can be provided on request.
Applications:
For general purpose power distribution in dry or wet location, best
suitable for direct burying in ground.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
System - i System - 0
Colour of insulation
Black with White numberYellow/Green strip, Black with White number
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
4. Armour :
A layer of galvanized round steel wires with a counter helix layer of
galvanized steel tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/
or special flame retardant, PVC sheath can be provided on request.
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core (SPLN)
(SNI IEC) : Black with White number
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
www.kabelindo.co.id26
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification : SNI IEC 60502-1: 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core :
(SNI IEC) : Light Blue, Brown
3. Inner sheath: Polyvinyl Chloride [PVC], Black colour
4. Shield: Hellically copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
Applications:
For indoor installations, in power and switching stations. As un-
derground cable, for difficult installation where the low weight is
particularly
advantageous.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Thickness
of
Insulation
(nom)
Thickness
of
Copper
tape
screened
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
21
21
29
29
38
38
48
48
66
90
120
150
180
230
280
320
375
430
510
590
27
27
36
36
47
47
59
59
78
102
134
180
210
260
315
320
355
409
472
525
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
218
223
230
241
261
274
297
326
364
425
464
526
589
691
749
819
911
909
1,031
1,139
218
231
263
280
348
369
417
445
582
771
1095
1368
1748
2336
3159
3807
4647
5756
7366
9117
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.4
2.6
2.8
3.0
12.1
12A
12.8
13.4
14.5
15.2
16.5
18.1
20.2
23.6
25.8
29.2
32.7
38.4
41.6
45.5
50.6
53.5
57.3
63.3
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2x1.5 re
2x1.5 rm
2x2.5 re
2x2.5 rm
2x4 re
2x4 rm
2x6 re
2x6 rm
2x10 rm
2x16 rm
2x25 rm
2x35 rm
2x50 rm
2x70 rm
2x95 rm
2x120 rm
2x150 rm
2x185 rm
2x240 rm
2x300 rm
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Annealed plain copper round solid or round circular stranded or
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
Applications:
sales@kabelindo.co.id 27
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60902-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core :
(SNI IEC) : Yellow/Green Strip, Light Blue, Brown
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Shield: Hellically copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For indoor installations, in power and switching stations.
As underground cable, for difficult installation where the low
weight is particularly advantageous.
Note: (re) round solid conductor
(rm) circular stranded conductor
(sm) sector shaped conductor
Packing : [D] Drum
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Thickness
of Copper
tape
screened
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C Standard
delivery
lengthConductor
Max
in Ground 0.1Insulation
Min
in Air 0.5 1.0
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0A6
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25A6
34.55
43.64
54.55
67.28
87.28
109.10
18
18
25
25
34
34
44
44
60
80
105
130
160
200
245
285
325
370
435
500
24
24
32
32
41
41
52
52
69
89
116
138
165
205
245
285
315
355
415
465
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
223
232
239
250
275
284
295
310
344
385
445
495
517
544
623
680
743
821
922
1,030
246
262
296
323
398
432
492
524
698
940
1359
1720
2018
2671
3641
4478
5486
6693
8727
10869
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.4
2.6
2.8
3.0
12.4
12.9
13.3
13.9
15.3
15.8
16.4
17.2
19.1
21.4
24.7
27.5
28.7
30.2
34.6
37.8
41.3
45.6
51.2
57.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1A
1.6
1.6
1.8
2.0
2.2
2.4
3x1.5 re
3x1.5 rrn
3x2.5 re
3x2.5 rm
3x4 re
3x4 rm
3x6 re
3x6 rm
3x10 rm
3x16 rm
3x25 rm
3x35 rm
3x50 sm
3x70 sm
3x95 sm
3x120 sm
3x150 sm
3x185 sm
3x240 sm
3x300 sm
Conductor Short Circuit
Current Capacity at
Specification :
SNI IEC 60902-1 : 2009
Annealed plain copper round solid or round circular stranded or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
www.kabelindo.co.id28
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1: 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core:
(SNI IEC) :
Yellow/Green Strip, Light Blue, Black, Brown
3.Inner covering / filler:
Extruded Polyvinyl Chloride (PVC), Black colour
4. Shield: Hellically copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
Applications:
For indoor installations, in power and switching stations. As
underground cable, for difficult installation where the low weight
is particularly advantageous.
Note : [re] round solid conductor
[rm] circular stranded conductor
[sm) sector shaped conductor
Packing : [D] Drum
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Annealed plain copper round solid or round circular stranded or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
Thickness
of Copper
tape
screened
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
024
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
18
18
25
25
34
34
44
44
60
80
105
130
160
200
245
285
325
370
435
500
24
24
32
32
41
41
52
52
69
89
116
138
165
205
245
285
315
355
415
465
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
236
241
256
266
293
308
317
333
367
416
490
544
572
643
734
803
866
968
1.087
1.202
281
296
348
373
470
509
585
627
847
1158
1683
2452
2640
3519
4717
5879
7135
8847
11363
13858
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.3
2.4
2.6
2.8
3.0
3.2
13.1
13.4
14.2
14.8
16.3
17.1
17.6
18.5
20.4
23.1
27.2
30.2
31.8
35.7
40.8
44.6
48.1
53.8
60.4
66.8
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
4x1.5 re
4x1.5 rm
4x2.5 re
4x2.5 rm
4x4 re
4x4 rm
4x6 re
4x6 rm
4x10 rm
4x16 rm
4x25 rm
4x35 rm
4x50 sm
4x70 sm
4x95 sm
4x120 sm
4x150 sm
4x185 sm
4x240 sm
4x300 sm
sales@kabelindo.co.id 29
Specification :
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core :
(SNI IEC) :
Yellow/Green strip, Light Blue, Black, Brown, Grey
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Shield: Hellically copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
For indoor installations, in power and switching stations. As un-
derground cable, for difficult installation where the low weight is
particularly advantageous.
Note : (re) round solid conductor
(rm) circular stranded conductor
Packing : [D] Drum
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Thickness
of Copper
tape
screened
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.17
0.17
0.29
0.29
0A6
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
18
18
25
25
34
34
44
44
60
80
105
130
160
24
24
32
32
41
41
52
52
69
89
116
138
165
50
50
50
50
50
50
50
50
50
40
40
40
30
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
256
265
279
292
313
333
340
356
403
454
535
587
680
327
345
408
435
564
606
708
761
1036
1415
2079
2685
3497
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
14.2
14.7
15.5
16.2
17.4
18.5
18.9
19.8
22.4
25.2
29.7
32.6
37.8
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
14
5x1.5 re
5x1.5 rm
5x2.5 re
5x2.5 rm
5x4 re
5x4 rm
5x6 re
5x6 rm
5x10 rm
5x16 rm
5x25 rm
5x35 rm
5x50 rm
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1 : 2009
Annealed plain copper round solid or round circular stranded or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
www.kabelindo.co.id30
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Control Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1: 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core:
Black with White printed number
3.Inner covering /filler:
Extruded Polyvinyl Chloride (PVC), Black colour
4. Shield: Hellically copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
Applications:
For indoor installations, in power and switching stations. As un-
derground cable, for difficult installation where the low weight is
particularly
advantageous.
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Thickness
of Copper
tape
screened
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.17
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
13
13
12
12
11
11
11
11
10
10
10
10
9
9
9
9
8
8
8
8
8
8
8
8
8
8
17
17
16
16
15
15
14
14
13
13
12
12
12
12
11
11
11
11
11
11
11
11
11
11
11
11
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1
268
279
290
297
328
335
337
346
349
364
367
374
382
392
400
410
428
450
455
481
497
529
572
601
607
634
357
372
394
418
475
496
518
545
586
613
642
675
718
757
778
820
872
928
1026
1085
1288
1356
1656
1752
1893
1990
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.0
2.0
14.9
15.5
16.1
16.5
18.2
18.6
18.7
19.2
19.4
20.2
20.4
20.8
21.2
21.8
22.2
22.8
23.8
25
25.3
26.7
27.6
29A
31.8
33.4
33.7
35.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
7x1.5 re
7x1.5 rm
8x1.5 re
8x1.5 rm
10x1.5 re
10x1.5 rm
12x1.5 re
12x1.5 rm
14x1.5 re
14x1.5 rm
16x1.5 re
16x1.5 rm
19x1.5 re
19x1.5 rm
21x1.5 re
21x1.5 rm
24x1.5 re
24x1.5 rm
30x1.5 re
30x1.5 rm
40x1.5 re
40x1.5 rm
52x1.5 re
52x1.5 rm
61x1.5 re
61x1.5 rm
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Annealed plain copper round solid or round circular stranded or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
sales@kabelindo.co.id 31
Thickness
of Copper
tape
screened
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.29
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.41
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
18
18
17
17
16
16
15
15
14
14
13
13
13
13
12
12
11
11
11
11
11
11
11
11
11
11
23
23
21
21
20
20
18
18
17
17
17
17
16
16
15
15
14
14
14
14
14
14
14
14
14
14
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
7.41
741
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
741
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
7.41
284
299
308
329
347
369
373
387
392
405
407
421
425
446
452
464
472
482
509
544
571
603
673
695
731
745
458
486
509
545
617
656
682
432
775
826
854
918
962
1027
1055
1136
1210
1292
1426
1535
1840
1973
2358
2534
2701
2895
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.0
2.0
2.1
2.1
2.1
2.1
15.8
16.6
17.1
18.3
19.3
20.5
20.7
21.5
21.8
22.5
22.6
23.4
23.6
24.8
25.1
25.8
26.2
26.8
28.3
30.2
31.7
33.5
37.4
38.6
40.6
41.4
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
7x2.5 re
7x2.5 rm
8x2.5 re
8x2.5 rm
10x2.5 re
10x2.5 rrn
12x2.5 re
12x2.5 rm
14x2.5 re
14x2.5 rm
16x2.5 re
16x2.5 rm
19x2.5 re
19x2.5 rm
21x2.5 re
21x2.5 rrn
24x2.5 re
24x2.5 rm
30x2.5 re
30x2.5 rm
40x2 5 re
40x2.5 rm
52)(2.5 re
52x2.5 rm
61x2.5 re
61x2.5 rrn
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1:2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core :
Black with White printed number
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Shield: Hellically copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/orspecial flame retardant, PVC sheath can be provided on
request.
Applications:
For indoor installations, in power and switching stations.
As underground cable, for difficult installation where the low
weight is particularly advantageous.
Note : (re) round solid conductor
(rm) circular stranded conductor
Packing : [D] Drum
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Control Cable
Specification :
SNI IEC 60502-1:2009
Annealed plain copper round solid or round circular stranded or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/orspecial flame retardant, PVC sheath can be provided on
request.
www.kabelindo.co.id32
Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Specification:
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core: (SPLN)
Light Blue and Brown Light Blue and Red or Light Blue and
Yellow or Light Blue and Black
(SNI IEC) :
Light Blue and Brown
3.Inner sheat:
Polyvinyl Chloride (PVC), Black colour
4. Screen:
Annealed copper wire with transverse helix of Annealed copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
Applications:
Indoor, in ducts, in the open, underground, if mechanical damage
is not expected
Note : [re] round solid conductor
[rm] circular stranded conductor
Packing : [D] Drum
Cross
section of
concentric
shield
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance
at 20°C
Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor
Max
in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
sq.mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
1.45
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.55
67.28
87.28
109.10
21
21
29
29
38
38
48
48
66
90
120
150
180
230
280
320
375
430
510
590
27
27
36
36
47
47
59
59
78
102
134
180
210
260
315
320
355
409
472
525
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
243
250
261
292
302
310
320
326
364
396
461
500
563
644
727
785
873
968
1,091
1,215
230
242
281
290
370
395
454
485
658
891
1207
1476
1928
2605
3557
4376
5208
6546
8368
10385
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.4
2.6
2.8
3.0
13.5
13.9
14.5
16.2
16.8
17.2
17.8
18.1
20.2
22
25.6
27.8
31.3
35.8
40.4
43.6
48.5
53.8
60.6
67.5
1.5
1.5
2.5
2.5
4
4
6
6
10
16
16
16
25
35
50
70
70
95
120
150
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
14
1.6
1.6
1.8
2.0
2.2
2.4
2x1.5 re/1.5
2x1.5 rm/1.5
2x2.5 re/2.5
2x2.5 rm/2.5
2x4 re/4
2x4 rm/4
2x6 re/6
2x6 rm/6
2x10 rm/10
2x16 rm/16
2x25 rm/16
2x35 rm/16
2x50 rm/25
2x70 rm/35
2x95 rm/50
2x120 rm/70
2x150 rm/70
2x185 rm/95
2x240 rm/120
2x300 rm/150
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Annealed plain copper round solid or round circular stranded or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request
sales@kabelindo.co.id 33
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Specification :
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1
Identification of core :
Light Blue, Red, Yellow or Light Blue, Red, Black or Light Blue, Yellow,
Black
(SNI IEC) :
Yellow/Green strip, Light Blue, Brown
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
4. Shield: Annealed copper wire with transverse helix of Annealed
copper tape
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Applications:
Indoor, in ducts, in the open, underground, if mechanical damage is
not expected.
Note : (re) round solid conductor
(rm) circular stranded conductor
(sm) sector shaped conductor
Packing : [D] Drum
Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable
Specification :
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Annealed plain copper round solid or round circular stranded or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
request.
Cross
section of
concentric
shield
Thickness
of
Insulation
(nom)
No. of
cores
and cross
section
area
Thickness
of outer
sheath
(nom)
Overall
Diameter
(approx)
Weight
of Cable
(approx]
Minimum
bending
radius
DC. Resistance Current Carrying
Capacity at 30°C
Conductor Short Circuit
Current Capacity at Standard
delivery
lengthConductor in Ground 0.1
second
Insulation
Min
in Air 0.5
second
1.0
second
sq.mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm. A kA kA kA m
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
1000/D
500/D
500/D
250/D
250/D
0.17
0.17
0.29
0.29
0.46
0.46
0.69
0.69
1.15
1.84
2.88
4.03
5.75
8.05
10.93
13.80
17.25
21.28
27.60
34.50
0.24
0.24
0.41
0.41
0.65
0.65
0.98
0.98
1.63
2.60
4.07
5.69
8.13
11.38
15.45
19.52
24.40
30.09
39.03
48.79
0.55
0.55
0.91
0.91
145
1.45
2.18
2.18
3.64
5.82
9.09
12.73
18.18
25.46
34.55
43.64
54.45
67.28
87.28
109.10
18
18
25
25
34
34
44
44
60
80
105
130
160
200
245
285
325
370
435
500
24
24
32
32
41
41
52
52
69
89
116
138
165
205
245
285
315
355
415
465
50
50
50
50
50
50
50
50
50
40
40
40
30
30
30
30
20
20
20
20
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
253
259
268
279
304
315
328
344
383
418
482
531
535
583
659
724
787
889
986
1,103
260
271
322
339
427
456
535
568
787
1068
1476
1438
2216
2985
4065
5073
6082
7516
9768
12186
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
24
2.6
2.8
3.0
14.1
144
14.9
15.5
16.9
17.5
18.2
19.1
21.3
23.2
26.8
29.5
29.7
324
36.6
40.2
43.7
494
54.8
61.3
1.5
1.5
2.5
2.5
4
4
6
6
10
16
16
16
25
35
50
70
70
95
120
150
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
3x1.5 re/1.5
3x1.5 rm/1.5
3x2.5 re/2.5
3x2.5 rm/2.5
3x4 re/4
3x4 rm/4
3x6 re/6
3x6 rm/6
3x10 rm/10
3x16 rm/16
3x25 rm/16
3x35 rm/16
3x50 sm/25
3x70 sm/35
3x95 sm/50
3x120 sm/70
3x150 sm/70
3x185 sm/95
3x240 sm/120
3x300 sm/150
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel
Katalog Kabel

More Related Content

What's hot

Design and function of surgical screws
Design and function of surgical screwsDesign and function of surgical screws
Design and function of surgical screwsOrthosurg2016
 
1103 p3-spk-teknik instalasi tenaga listrik
1103 p3-spk-teknik instalasi tenaga listrik1103 p3-spk-teknik instalasi tenaga listrik
1103 p3-spk-teknik instalasi tenaga listrikWinarto Winartoap
 
Installation ACCC INA_Rev20.1.doc
Installation ACCC INA_Rev20.1.docInstallation ACCC INA_Rev20.1.doc
Installation ACCC INA_Rev20.1.docpstjatengdua
 
Sistim tarikan kabel pln 20 kv
Sistim tarikan kabel pln 20 kvSistim tarikan kabel pln 20 kv
Sistim tarikan kabel pln 20 kvNurdinSudrajat
 
Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00
Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00
Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00Arber Dogani
 
Transmission Line Towers and details
Transmission Line Towers and detailsTransmission Line Towers and details
Transmission Line Towers and detailsMahesh Sontyal
 
Disconnecting Switch ( Saklar Pemisah )
Disconnecting Switch ( Saklar Pemisah )Disconnecting Switch ( Saklar Pemisah )
Disconnecting Switch ( Saklar Pemisah )TEMMY NGEDY
 
Modeling and Simulation of Bone Healing Through Electrical Stimulation
Modeling and Simulation of Bone Healing Through Electrical Stimulation Modeling and Simulation of Bone Healing Through Electrical Stimulation
Modeling and Simulation of Bone Healing Through Electrical Stimulation Vishal Kheni
 
Interconnects in Reconfigurable Architectures
Interconnects in Reconfigurable ArchitecturesInterconnects in Reconfigurable Architectures
Interconnects in Reconfigurable ArchitecturesSudhanshu Janwadkar
 
Persyaratan Umum Instalasi Listrik (Puil 2000)
Persyaratan Umum Instalasi Listrik (Puil 2000)Persyaratan Umum Instalasi Listrik (Puil 2000)
Persyaratan Umum Instalasi Listrik (Puil 2000)Ellan Syahnoorizal Siregar
 
Surgical Approach to Hip and Acetabulum
Surgical Approach to Hip and AcetabulumSurgical Approach to Hip and Acetabulum
Surgical Approach to Hip and AcetabulumSijan Bhattachan
 
Analysis of waveform and pulse sequence in partial discharge
Analysis of waveform and pulse sequence in partial dischargeAnalysis of waveform and pulse sequence in partial discharge
Analysis of waveform and pulse sequence in partial dischargeRamdan Mohamad Febriana
 
Distal radioulnar joint
Distal radioulnar joint Distal radioulnar joint
Distal radioulnar joint orthoprince
 

What's hot (20)

Ankle and foot arthrodesis
Ankle and foot arthrodesisAnkle and foot arthrodesis
Ankle and foot arthrodesis
 
Design and function of surgical screws
Design and function of surgical screwsDesign and function of surgical screws
Design and function of surgical screws
 
1103 p3-spk-teknik instalasi tenaga listrik
1103 p3-spk-teknik instalasi tenaga listrik1103 p3-spk-teknik instalasi tenaga listrik
1103 p3-spk-teknik instalasi tenaga listrik
 
JARINGAN TEGANGAN RENDAH (JTR)
JARINGAN TEGANGAN RENDAH (JTR)JARINGAN TEGANGAN RENDAH (JTR)
JARINGAN TEGANGAN RENDAH (JTR)
 
Installation ACCC INA_Rev20.1.doc
Installation ACCC INA_Rev20.1.docInstallation ACCC INA_Rev20.1.doc
Installation ACCC INA_Rev20.1.doc
 
JARINGAN TEGANGAN RENDAH ( JTR)
JARINGAN TEGANGAN RENDAH ( JTR)JARINGAN TEGANGAN RENDAH ( JTR)
JARINGAN TEGANGAN RENDAH ( JTR)
 
Sistim tarikan kabel pln 20 kv
Sistim tarikan kabel pln 20 kvSistim tarikan kabel pln 20 kv
Sistim tarikan kabel pln 20 kv
 
220 kv G.G.S (report)
220 kv G.G.S (report)220 kv G.G.S (report)
220 kv G.G.S (report)
 
Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00
Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00
Ohl transmission lines opgw instalation procedure for fiber optic cables rev.00
 
73964016 sop-langkah-kerja
73964016 sop-langkah-kerja73964016 sop-langkah-kerja
73964016 sop-langkah-kerja
 
Transmission Line Towers and details
Transmission Line Towers and detailsTransmission Line Towers and details
Transmission Line Towers and details
 
Disconnecting Switch ( Saklar Pemisah )
Disconnecting Switch ( Saklar Pemisah )Disconnecting Switch ( Saklar Pemisah )
Disconnecting Switch ( Saklar Pemisah )
 
Modeling and Simulation of Bone Healing Through Electrical Stimulation
Modeling and Simulation of Bone Healing Through Electrical Stimulation Modeling and Simulation of Bone Healing Through Electrical Stimulation
Modeling and Simulation of Bone Healing Through Electrical Stimulation
 
Interconnects in Reconfigurable Architectures
Interconnects in Reconfigurable ArchitecturesInterconnects in Reconfigurable Architectures
Interconnects in Reconfigurable Architectures
 
Persyaratan Umum Instalasi Listrik (Puil 2000)
Persyaratan Umum Instalasi Listrik (Puil 2000)Persyaratan Umum Instalasi Listrik (Puil 2000)
Persyaratan Umum Instalasi Listrik (Puil 2000)
 
Surgical Approach to Hip and Acetabulum
Surgical Approach to Hip and AcetabulumSurgical Approach to Hip and Acetabulum
Surgical Approach to Hip and Acetabulum
 
Модернізація турбін АЕС і ТЕС
Модернізація турбін АЕС і ТЕСМодернізація турбін АЕС і ТЕС
Модернізація турбін АЕС і ТЕС
 
Analysis of waveform and pulse sequence in partial discharge
Analysis of waveform and pulse sequence in partial dischargeAnalysis of waveform and pulse sequence in partial discharge
Analysis of waveform and pulse sequence in partial discharge
 
Distal radioulnar joint
Distal radioulnar joint Distal radioulnar joint
Distal radioulnar joint
 
SALURAN TEGANGAN MENENGAH
SALURAN TEGANGAN MENENGAH SALURAN TEGANGAN MENENGAH
SALURAN TEGANGAN MENENGAH
 

Viewers also liked

СПИК 2016_Онлайн-маркетинг «на автомате»
СПИК 2016_Онлайн-маркетинг «на автомате»СПИК 2016_Онлайн-маркетинг «на автомате»
СПИК 2016_Онлайн-маркетинг «на автомате»SOLOMOTO_RU
 
Training1 at jordy-paenen
Training1 at jordy-paenenTraining1 at jordy-paenen
Training1 at jordy-paenenjordy paenen
 
Brisbane War Stories – Edited by Sophie Tarrant
Brisbane War Stories – Edited by Sophie TarrantBrisbane War Stories – Edited by Sophie Tarrant
Brisbane War Stories – Edited by Sophie Tarrantsophietarrantbulimba
 
Vinay Panchal CV SAFETY 2015
Vinay Panchal CV SAFETY 2015Vinay Panchal CV SAFETY 2015
Vinay Panchal CV SAFETY 2015Vinay Panchal
 
HV Circuit Breaker Operating Mechanisms - Hydraulic Systems
HV Circuit Breaker Operating Mechanisms - Hydraulic SystemsHV Circuit Breaker Operating Mechanisms - Hydraulic Systems
HV Circuit Breaker Operating Mechanisms - Hydraulic SystemsLiving Online
 
HIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGH
HIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGHHIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGH
HIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGHShankar Singh
 
Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...
Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...
Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...Ajjay Kumar Gupta
 
Intrusion detection and prevention system
Intrusion detection and prevention systemIntrusion detection and prevention system
Intrusion detection and prevention systemNikhil Raj
 
test paper - marking schedule
test paper - marking scheduletest paper - marking schedule
test paper - marking scheduleRichard Smith
 

Viewers also liked (20)

СПИК 2016_Онлайн-маркетинг «на автомате»
СПИК 2016_Онлайн-маркетинг «на автомате»СПИК 2016_Онлайн-маркетинг «на автомате»
СПИК 2016_Онлайн-маркетинг «на автомате»
 
Training1 at jordy-paenen
Training1 at jordy-paenenTraining1 at jordy-paenen
Training1 at jordy-paenen
 
Brisbane War Stories – Edited by Sophie Tarrant
Brisbane War Stories – Edited by Sophie TarrantBrisbane War Stories – Edited by Sophie Tarrant
Brisbane War Stories – Edited by Sophie Tarrant
 
Vinay Panchal CV SAFETY 2015
Vinay Panchal CV SAFETY 2015Vinay Panchal CV SAFETY 2015
Vinay Panchal CV SAFETY 2015
 
Informacje o BNI
Informacje o BNIInformacje o BNI
Informacje o BNI
 
Abdelbaset HSE CV
Abdelbaset HSE CVAbdelbaset HSE CV
Abdelbaset HSE CV
 
Ανασκόπηση 2013
Ανασκόπηση 2013Ανασκόπηση 2013
Ανασκόπηση 2013
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breaker
 
Updated CV
Updated CVUpdated CV
Updated CV
 
Cathodic Protection Cables - XLPE/PVC 600-1000v
Cathodic Protection Cables - XLPE/PVC 600-1000vCathodic Protection Cables - XLPE/PVC 600-1000v
Cathodic Protection Cables - XLPE/PVC 600-1000v
 
Resume GWEN FRANCISCO
Resume GWEN FRANCISCOResume GWEN FRANCISCO
Resume GWEN FRANCISCO
 
HV Circuit Breaker Operating Mechanisms - Hydraulic Systems
HV Circuit Breaker Operating Mechanisms - Hydraulic SystemsHV Circuit Breaker Operating Mechanisms - Hydraulic Systems
HV Circuit Breaker Operating Mechanisms - Hydraulic Systems
 
Study of circuit breakers
Study of circuit breakersStudy of circuit breakers
Study of circuit breakers
 
HIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGH
HIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGHHIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGH
HIGH VOL TAGE TESTING OF TRANSFORMER BY HARI SHANKAR SINGH
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakers
 
Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...
Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...
Power Cables, Electrical Power & Industrial Cable, Electrical Wire, PVC Wire ...
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakers
 
Intrusion detection and prevention system
Intrusion detection and prevention systemIntrusion detection and prevention system
Intrusion detection and prevention system
 
test paper - marking schedule
test paper - marking scheduletest paper - marking schedule
test paper - marking schedule
 
Mosin_Resume
Mosin_ResumeMosin_Resume
Mosin_Resume
 

Similar to Katalog Kabel

B3_Communications_Brochure
B3_Communications_BrochureB3_Communications_Brochure
B3_Communications_BrochureDonna M Sheridan
 
Nexans Airfield Ground Lighting Cables (Primary Secondary)
Nexans Airfield Ground Lighting Cables (Primary  Secondary)Nexans Airfield Ground Lighting Cables (Primary  Secondary)
Nexans Airfield Ground Lighting Cables (Primary Secondary)Thorne & Derrick International
 
Xlpe insulated power cable
Xlpe insulated power cableXlpe insulated power cable
Xlpe insulated power cable辉 李
 
11kV Cable - Single Core XLPE Insulated AWA BS6622 - BS7835
11kV Cable - Single Core XLPE Insulated AWA BS6622 - BS783511kV Cable - Single Core XLPE Insulated AWA BS6622 - BS7835
11kV Cable - Single Core XLPE Insulated AWA BS6622 - BS7835Thorne & Derrick International
 
Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors Thorne & Derrick International
 
Nexans Euromold MV Separable Connectors & Bushings - Interface C Compact
Nexans Euromold MV Separable Connectors & Bushings - Interface C CompactNexans Euromold MV Separable Connectors & Bushings - Interface C Compact
Nexans Euromold MV Separable Connectors & Bushings - Interface C CompactThorne & Derrick International
 
Power cable
Power cablePower cable
Power cable辉 李
 
Introduction cable engineering
Introduction cable engineeringIntroduction cable engineering
Introduction cable engineeringDaniel García
 
Nexans AFNP36 33kV Slip-On Outdoor High Voltage Cable Terminations
Nexans AFNP36 33kV Slip-On Outdoor High Voltage Cable TerminationsNexans AFNP36 33kV Slip-On Outdoor High Voltage Cable Terminations
Nexans AFNP36 33kV Slip-On Outdoor High Voltage Cable TerminationsThorne & Derrick International
 
Nexans Euromold MV Separable Connectors & Bushings - Interface E
Nexans Euromold MV Separable Connectors & Bushings - Interface ENexans Euromold MV Separable Connectors & Bushings - Interface E
Nexans Euromold MV Separable Connectors & Bushings - Interface EThorne & Derrick International
 
Nexans Euromold Interface E 5/8" 700 Series Cable Connectors
Nexans Euromold Interface E 5/8" 700 Series Cable Connectors Nexans Euromold Interface E 5/8" 700 Series Cable Connectors
Nexans Euromold Interface E 5/8" 700 Series Cable Connectors Thorne & Derrick International
 
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-OnNexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-OnThorne & Derrick International
 
Power system slide notes
Power system slide notesPower system slide notes
Power system slide notesmichaeljmack
 
CMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable GlandsCMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable GlandsThorne & Derrick International
 
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands Thorne & Derrick International
 
CMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable GlandsCMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable GlandsThorne & Derrick International
 

Similar to Katalog Kabel (20)

B3_Communications_Brochure
B3_Communications_BrochureB3_Communications_Brochure
B3_Communications_Brochure
 
Nexans Airfield Ground Lighting Cables (Primary Secondary)
Nexans Airfield Ground Lighting Cables (Primary  Secondary)Nexans Airfield Ground Lighting Cables (Primary  Secondary)
Nexans Airfield Ground Lighting Cables (Primary Secondary)
 
Xlpe insulated power cable
Xlpe insulated power cableXlpe insulated power cable
Xlpe insulated power cable
 
11kV Cable - Single Core XLPE Insulated AWA BS6622 - BS7835
11kV Cable - Single Core XLPE Insulated AWA BS6622 - BS783511kV Cable - Single Core XLPE Insulated AWA BS6622 - BS7835
11kV Cable - Single Core XLPE Insulated AWA BS6622 - BS7835
 
Draka Offshore Cables Basic Program IEC / NEK 606
Draka Offshore Cables Basic Program IEC / NEK 606Draka Offshore Cables Basic Program IEC / NEK 606
Draka Offshore Cables Basic Program IEC / NEK 606
 
Prysmian Draka Cable Catalogue NEK606 BFOU RFOU
Prysmian Draka Cable Catalogue NEK606 BFOU RFOUPrysmian Draka Cable Catalogue NEK606 BFOU RFOU
Prysmian Draka Cable Catalogue NEK606 BFOU RFOU
 
Cable Course.pptx
Cable Course.pptxCable Course.pptx
Cable Course.pptx
 
Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors Nexans Euromold Interface C 400 Compact Series Cable Connectors
Nexans Euromold Interface C 400 Compact Series Cable Connectors
 
Nexans Euromold MV Separable Connectors & Bushings - Interface C Compact
Nexans Euromold MV Separable Connectors & Bushings - Interface C CompactNexans Euromold MV Separable Connectors & Bushings - Interface C Compact
Nexans Euromold MV Separable Connectors & Bushings - Interface C Compact
 
Power cable
Power cablePower cable
Power cable
 
Introduction cable engineering
Introduction cable engineeringIntroduction cable engineering
Introduction cable engineering
 
Nexans AFNP36 33kV Slip-On Outdoor High Voltage Cable Terminations
Nexans AFNP36 33kV Slip-On Outdoor High Voltage Cable TerminationsNexans AFNP36 33kV Slip-On Outdoor High Voltage Cable Terminations
Nexans AFNP36 33kV Slip-On Outdoor High Voltage Cable Terminations
 
Nexans Euromold MV Separable Connectors & Bushings - Interface E
Nexans Euromold MV Separable Connectors & Bushings - Interface ENexans Euromold MV Separable Connectors & Bushings - Interface E
Nexans Euromold MV Separable Connectors & Bushings - Interface E
 
Nexans Euromold Interface E 5/8" 700 Series Cable Connectors
Nexans Euromold Interface E 5/8" 700 Series Cable Connectors Nexans Euromold Interface E 5/8" 700 Series Cable Connectors
Nexans Euromold Interface E 5/8" 700 Series Cable Connectors
 
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-OnNexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
Nexans Cable Terminations - Heat Shrink, Cold Shrink, Slip-On
 
Power system slide notes
Power system slide notesPower system slide notes
Power system slide notes
 
CMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable GlandsCMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S Barrier Glands Exd Flameproof (ATEX) Cable Glands
 
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-20S/16 Barrier Glands Exd Flameproof (ATEX) Cable Glands
 
CMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable GlandsCMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable Glands
CMP PX2K-50S Barrier Glands Exd Flameproof (ATEX) Cable Glands
 
CMP Barrier Glands (Explosion Proof Cable Glands)
CMP Barrier Glands (Explosion Proof Cable Glands)CMP Barrier Glands (Explosion Proof Cable Glands)
CMP Barrier Glands (Explosion Proof Cable Glands)
 

More from BENRY APRIANTO HUTAPEA (20)

Cast Iron Valves
Cast Iron ValvesCast Iron Valves
Cast Iron Valves
 
Metal Bronze Brass Valves
Metal Bronze Brass ValvesMetal Bronze Brass Valves
Metal Bronze Brass Valves
 
Cable Tray and Ladder
Cable Tray and LadderCable Tray and Ladder
Cable Tray and Ladder
 
PVC Pipe
PVC PipePVC Pipe
PVC Pipe
 
Carbon Steel Pipe
Carbon Steel PipeCarbon Steel Pipe
Carbon Steel Pipe
 
Busduct
BusductBusduct
Busduct
 
Cooling Tower Modular Design Crossflow Type
Cooling Tower Modular Design Crossflow TypeCooling Tower Modular Design Crossflow Type
Cooling Tower Modular Design Crossflow Type
 
Cooling Tower Crossflow & Counter Type
Cooling Tower Crossflow & Counter TypeCooling Tower Crossflow & Counter Type
Cooling Tower Crossflow & Counter Type
 
Trafo/ Transformator
Trafo/ TransformatorTrafo/ Transformator
Trafo/ Transformator
 
Incoming & Outgoing
Incoming & OutgoingIncoming & Outgoing
Incoming & Outgoing
 
Cubicles
CubiclesCubicles
Cubicles
 
Penangkal Petir/ Lightning Protection
Penangkal Petir/ Lightning ProtectionPenangkal Petir/ Lightning Protection
Penangkal Petir/ Lightning Protection
 
MCB c60
MCB c60MCB c60
MCB c60
 
Masterpact NW800 - 6300A
Masterpact NW800 - 6300AMasterpact NW800 - 6300A
Masterpact NW800 - 6300A
 
MCCB Easy Pact ECLB
MCCB Easy Pact ECLBMCCB Easy Pact ECLB
MCCB Easy Pact ECLB
 
Lampu Tembak/ Sorot 400W
Lampu Tembak/ Sorot 400WLampu Tembak/ Sorot 400W
Lampu Tembak/ Sorot 400W
 
Led Strip 220V
Led Strip 220VLed Strip 220V
Led Strip 220V
 
LED high bay & Conventional LED
LED high bay & Conventional LEDLED high bay & Conventional LED
LED high bay & Conventional LED
 
Compact Fluorescent Lamp
Compact Fluorescent LampCompact Fluorescent Lamp
Compact Fluorescent Lamp
 
LED Emergency EXIT Light
LED Emergency EXIT LightLED Emergency EXIT Light
LED Emergency EXIT Light
 

Recently uploaded

Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...ranjana rawat
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordAsst.prof M.Gokilavani
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...ranjana rawat
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...roncy bisnoi
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 

Recently uploaded (20)

Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 

Katalog Kabel

  • 2. www.kabelindo.co.id Table Of Contents TYPE PAGEDESCRIPTION Cu/PVC 450/750 V (NYA) Cu/PVC/PVC 300/500 V (NYM) Cu/PVC 450/750 V (NYAF) Cu/PVC/PVC 300/500 V (NYMHY) Cu/PVC/PVC 0.6/1 kV (NYY) Cu/PVC/PVC 0.6/1 kV Control Cable (NYY) Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY) Cu/PVC/SFA/PVC 0.6/1 kV Control Cable (NYFGbY) Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Cu/PVC/SWA/PVC 0.6/1 kV Control Cable (NYRGbY) Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Cu/PVC/CTS/PVC 0.6/1 kV Control Cable (NYSY) Cu/PVC/CWS/PVC 0.6/1 kV (NYCY) Cu/PVC/CWS/PVC 0.6/1 kV Control Cable (NYCY) Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY) Cu/PVC/DSTA/PVC 0.6/1 kV Control Cable (NYBY) Derating Factors Conversion Table of Conductor Size Standards 2 3 - 5 6 7 8 - 12 13 - 14 15 - 18 19 - 20 21 - 24 25 - 26 27 - 30 31 - 32 33 - 35 36 - 37 38 - 41 42 - 43 44 - 48 49 50 Copper Conductor Building Wire Copper Conductor PVC Insulated and PVC Sheathed Indoor Cable Single Core Flexible Copper Conductor PVC Insulated Multi Core Flexible Copper Conductor PVC Insulated & PVC Sheathed Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable Copper Conductor PVC Insulated & PVC Sheathed non Armoured Control Cable Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable Copper Conductor PVC Insulated, Copper tape Screened and PVC Sheathed Power Cable Copper Conductor PVC Insulated, Copper tape Screened and PVC Sheathed Cotrol Cable Copper Conductor PVC Insulated, Concentric Copper wire Screened and PVC Sheathed Power Cable Copper Conductor PVC Insulated, Concentric Copper wire Screened and PVC Sheathed Control Cable Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
  • 3. sales@kabelindo.co.id 1 Copper Conductor PVC Insulated Building Wire Cu/PVC 450/750 V (NYA) Specification : SPLN 42-1 : 1991 IEC 227 SNI 04-6629 : 3-2006 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 2 - 3 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC) complied with SPLN 41-2 Identification: Yellow/Green strip, Light Blue, Black, Yellow, Red colour Applications: Permanent installation in conduit or exposed wiring in dry location. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [C] Coil [D] Drum Conductor Nominal crosssection area Nominal thickness Insulation Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max in Pipe 0.1 second Insulation Min in Air 0.5 second 1.0 sq.mm mm mm kg/km mm Ohm/km AM.Ohm. A kA kA kA mm 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 2.6 19 20 31 33 45 48 65 71 108 175 273 367 523 692 962 1192 1511 1844 2430 3015 3863 3.3 3.4 3.9 4.2 4.4 4.7 4.9 5.4 6.8 8.0 9.8 11 13 15 17 19 21 23.5 26.5 29.5 33.5 1.5 re 1.5 rm 2.5 re 2.5 rm 4 re 4 rm 6 re 6 rm 10 rm 16 rm 25 rm 35 rm 50 rm 70 rm 95 rm 120 rm 150 rm 185 rm 240 rm 300 rm 400 rm 15 15 19 19 25 25 33 33 45 61 83 103 132 165 197 235 - - - - - 50 50 50 50 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 59 61 70 76 79 85 88 97 122 144 176 198 234 270 306 342 378 423 477 531 603 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 3000/D 3000/D 2000/D 1000/D 1000/D 1000/D 500/D 500/D 500 /D 500 /D 500/D 500/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 46.00 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 S.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 65.05 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.5 67.28 87.28 109.10 145.46 24 24 32 32 42 42 54 54 73 98 129 158 197 245 290 345 390 445 525 605 725
  • 4. www.kabelindo.co.id2 Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable Cu/PVC/PVC 300/500 V (NYM) Specification : SPLN 42-2 : 1992 IEC 227 SNI : 04-6629.4-2006 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 42 - 2 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 Identification of core Identification of core Light Blue, Black (SPLN) Ligh Blue, Brown (SNI) 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Outer sheath: Extruded Polyvinyl Chloride [PVC], White colour Applications: Permanent installation in conduit under plaster or exposed wiring in dry location. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [C] Coil [D] Drum Conductor Nominal crosssection area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity in air Short Circuit Current Capacity at Standard delivery lengthConductor Max 30°C 0.1 second Insulation Min 40°C 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 1000/D 1000/D 1000/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3 6 4 5.82 9.09 12 73 16 16 22 22 30 30 39 39 53 71 94 117 19 19 25 25 34 34 44 44 61 82 108 134 50 50 50 50 50 50 50 50 50 40 40 40 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 158 164 173 182 203 210 221 236 326 401 401 448 112 119 145 157 209 227 267 291 453 621 958 1249 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.6 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.2 1.2 8.8 9.1 9.6 10.1 11.3 11.9 12.3 13.1 16 18.1 22.3 24.9 2x1.5 re 2x 1.5 rm 2x2.5 re 2x2.5 rm 2x4 re 2x4 rm 2x6 re 2x6 rm 2x 10 rm 2x 16 rm 2x25 rm 2x35 rm
  • 5. sales@kabelindo.co.id 3 Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable Cu/PVC/PVC 300/500 V (NYM) Specification : SPLN 42-2 : 1992 IEC 227 SNI : 04-6629.4-2006 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 Identification of core (SPLN) 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Outer sheath: Extruded Polyvinyl Chloride [PVC], White colour Applications: Permanent installation in conduit under plaster or exposed wiring in dry location. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [C] Coil [D] Drum No. of cores Yellow/Green strip, Light Blue, Brown Yellow/Green strip, Light Blue, Black, Brown Colour of insulation Three Four No. of cores System - i Light Blue, Yellow, Black Light Blue, Red, Yellow, Black Yellow/Green strip, Light Blue, Black Yellow/Green strip, Light Blue, Yellow, Black System - o Colour of insulation Three Four Conductor Nominal crosssection area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity in air Short Circuit Current Capacity at Standard delivery lengthConductor Max 30°C 0.1 second Insulation Min 40°C 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 1000/D 1000/D 1000/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3 6 4 5.82 9.09 12 73 16 16 22 22 30 30 39 39 53 71 94 117 19 19 25 25 34 34 44 44 61 82 108 134 50 50 50 50 50 50 50 50 50 40 40 40 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 166 173 182 191 214 227 234 248 306 346 425 475 132 140 175 188 254 274 331 359 562 784 1214 1593 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.6 1.6 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.2 1.2 9.2 9.6 10.1 10.6 11.9 12.6 13 13.8 17 19.2 23.6 26.4 3x1.5 re 3x1.5 rm 3x2.5 re 3x2.5 rm 3x4 re 3x4 rm 3x6 re 3x6 rm 3x10 rm 3x16 rm 3x25 rm 3x35 rm 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 1000/D 1000/D 1000/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3 6 4 5.82 9.09 12 73 16 16 22 22 30 30 39 39 53 71 94 117 19 19 25 25 34 34 44 44 61 82 108 134 50 50 50 50 50 50 50 50 50 40 40 40 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 178 185 196 207 232 245 254 270 333 378 466 520 159 169 214 230 313 338 411 446 701 987 1,530 2,014 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.6 1.6 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.2 1.2 9.9 10.3 10.9 11.5 12.9 13.6 14.1 15 18.5 21 25.9 28.9 4x1.5 re 4x1.5 rm 4x2.5 re 4x2.5 rm 4x4 re 4x4 rm 4x6 re 4x6 rm 4x10 rm 4x16 rm 4x25 rm 4x35 rm Identification of core (SNI)
  • 6. www.kabelindo.co.id4 Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable Cu/PVC/PVC 300/500 V (NYM) Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41-2 Identification of core: [SPLN] Yellow/Green strip, Light Blue, Red, Yellow, Black, Identification of core: [SNI] Yellow/Green,Light Blue, Black, Brown and Grey 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Outer sheath: Extruded Polyvinyl Chloride [PVC], White colour Applications: Permanent installation in conduit under plaster or exposed wiring in dry location. Note : [re] round solid conductor [rm] circular stranded conductor Packing : (C) Coil (D) Drum Conductor Nominal crosssection area Nominal Thickness Insulation Outer Sheath (approx)(approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity in air Short Circuit Current Capacity at Standard delivery lengthConductor Max 30°C 0.1 second Insulation Min 40°C 0.5 second 1.0 second sq.mm mmmmmm kg/km mm Ohm/km M.Ohm.km AA kAkAkA m 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 1000/D 1000/D 1000/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 16 16 22 22 30 30 39 39 53 71 94 117 19 19 25 25 34 34 44 44 61 82 108 134 50 50 50 50 50 50 50 50 50 40 40 40 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 193 200 212 225 252 266 277 295 364 414 509 571 189 201 256 276 377 407 499 540 854 1208 1874 2471 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.6 1.6 1.6 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.2 1.2 10.7 11.1 11.8 12.5 14 14.8 15.4 16.4 20.2 23 28.3 31.7 5x1.5 re 5x1.5 rm 5x2.5 re 5x2.5 rm 5x4 re 5x4 rm 5x6 re 5x6 rm 5x10 rm 5x16 rm 5x25 rm 5x35 rm Specification : SPLN 42-2 : 1992 IEC 227 SNI : 04-6629.4-2006
  • 7. sales@kabelindo.co.id 5 Single Core Flexible Copper Conductor PVC Insulated Cu/PVC/PVC 450/750 V (NYAF) Specification : SPLN 42-3 : 1992 IEC 227 SNI : 04-6629.5-2006 Constructions: 1. Conductor: Annealed plain copper wires bunch stranded, according to SPLN 41-1; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41-2 Identification: Yellow/Green strip, Light Blue, Black, Yellow, Red colour Applications: Used for fixed installation inside appliances, switchgear and controlgear. Note : [f] Flexible bunched wire Packing : [C] Coil [D] Drum Conductor Nominal thickness Insulation Nominal crosssection area No. of wire and Diameter Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max in Pipe 0.1 second Insulation Min in Air 0.5 second 1.0 second sq.mm mmmm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 500/D 500/D 500/D 500/D 500/D 500/D 500/D 500/D 500/D 500/D 0.06 0.09 0.12 0.17 0.29 0.46 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.08 0.12 0.16 0.24 0.41 0.65 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.18 0.27 0.36 0.55 0.91 1.45 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.5 67.28 87.28 109.10 - - 19 24 32 41 53 72 97 128 156 195 243 287 342 386 441 525 605 2.5 7 11 15 20 25 33 45 61 82 102 131 164 205 233 - - - - 50 50 50 50 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 39.0 26.0 19.5 13.3 7.98 4.95 3.30 1.91 1.21 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0.0801 0.0641 47 50 54 63 76 90 113 133 155 194 216 261 297 351 378 423 468 531 585 10 13 16 23 36 51 73 116 180 275 385 550 750 1000 1240 1550 1900 2450 3025 0.6 0.6 0.6 0.7 0.8 0.8 0.8 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.5 4.2 5 6.3 7.4 8.6 10.8 12 14.5 16.5 19.5 21 23.5 26 29.5 32.5 0.5 f 0.75 f 1.0 f 1.5 f 2.5 f 4 f 6 f 10 f 16 f 25 f 35 f 50 f 70 f 95 f 120 f 150 f 185 f 240 f 300 f 16/0.2 24/0.2 32/0.2 30/0.25 50/0.25 56/0.3 84/0.3 84/0.4 126/0.4 196/0.4 278/0.4 398/0.4 360/0.5 475/0.5 608/0.5 760/0.5 925/0.5 1221/0.5 1517/0.5
  • 8. www.kabelindo.co.id6 Multi-Core Flexible Copper Conductor PVC Insulated & PVC Sheathed Cu/PVC/PVC 300/500 V (NYMHY) Specification : SPLN 42-6 : 1991 IEC 227 SNI : 04-6629.5-2006 Constructions: 1. Conductor: Annealed plain copper wires bunch stranded, according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41-2 Identification of core [SPLN] No. of cores System - i System - O Colour of insulation Light Blue, Yellow, Black - Yellow/Green strip, Light Blue, BlackThree Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, BlackFour Light Blue, Black-Two Yellow/Green strip, Light Blue, Red, Yellow, BlackFive Identification of core [SNI] No. of cores Colour of insulation Four Yellow/Green strip, Light Blue, Black, Brown Three Yellow/Green strip, Light Blue, Brown Two Light Blue, Brown Five Yellow/Green, Light Blue, Black, Brown, and Grey 3. Outer Sheath: Extruded Polyvinyl Chloride [PVC] White colour Applications: These cables are useful for use in dry or damp locations for medium duties in domestic premises, kitchens, offices, washing machines, refrigerators, etc. Can be used for cooking and heating appliances provided that the cable does not come in contact with the hot parts. Note : [f] Flexible bunched wire Packing : [C] Coil Conductor Insulation Outer Sheath Nominal cross section area No. of wire and Diameter of wire Overall Diameter (approx) Weight of Cable radius Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity in air Short Circuit Current Capacity at Standard delivery lengthConductor Max 30°C 0.1 secInsulation Min 40°C 0.5 sec 1.0 sec sq.mm mm mmmm mm mm mm Ohm/km AM.Ohm.km A kA kA kA m 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 100/C 0.06 0.09 0.12 0.17 0.29 0.46 0.06 0.09 0.12 0.17 0.29 0.46 0.06 0.09 0.12 0.17 0.29 0.46 0.06 0.09 0.12 0.17 0.29 0.46 0.08 0.12 0.16 0.24 0.41 0.65 O.OB 0.12 0.16 0.24 0.41 0.65 0.08 0.12 0.16 0.24 0.41 0.65 O.OB 0.12 0.16 0.24 0.41 0.65 0.18 0.27 0.36 0.55 0.91 1.45 0.18 0.27 0.36 0.55 0.91 1.45 0.18 0.27 0.36 0.55 0.91 1.45 0.18 0.27 0.36 0.55 0.91 1.45 1.8 5.5 9.2 13.8 18.4 25.3 1.8 5.5 9.2 13.8 18.4 25.3 1.8 5.5 9.2 13.B 18.4 25.3 1.8 5.5 9.2 13.8 18.4 25.3 2 6 10 15 20 27.5 2 6 10 15 20 27.5 2 6 10 15 20 27.5 2 6 10 15 20 27.5 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 39 26 19.5 13.3 7.98 4.95 39 26 19.5 13.3 7.98 4.95 39 26 19.5 13.3 7.98 4.95 39 26 19.5 13.3 7.98 4.95 108 117 121 139 169 203 115 122 128 149 184 216 126 133 144 164 202 236 140 149 157 185 223 257 56 56 66 90 140 209 60 77 90 147 190 265 70 96 121 167 237 330 90 116 139 194 291 391 0.8 O.B 0.8 0.9 1.0 1.0 0.8 0.8 0.8 O.B 1.0 1.0 0.8 O.B O.B 0.9 1.0 1.0 O.B O.B 0.8 0.9 1.0 1.0 6 6.5 6.7 7.7 9.4 11.3 6.4 6.8 7.1 8.3 10.2 12 7 7.4 B 9.1 11.2 13.1 7.B B.3 8.7 10.3 12.4 14.3 2 x 0.5 f 2 x 0.75 f 2 x 1.0 f 2 x 1.5 f 2 x 2.5 f 2 x 4 f 3 x 0.5 f 3 x 0.75 f 3 x 1.0 f 3 x 1.5 f 3 x 2.5 f 3 x 4 f 4 x 0.5 f 4 x 0.75 f 4 x 1.0 f 4 x 1.5 f 4 x 2.5 f 4 x 4 f 5 x 0.5 f 5 x 0.75 f 5 x 1.0 f 5 x 1.5 f 5 x 2.5 f 5 x 4 f 16/0.2 24/0.2 32/0.2 30/0.25 50/0.25 56/0.3 16/0.2 24/0.2 32/0.2 30/0.25 50/0.25 56/0.3 16/0.2 24/0.2 32/0.2 30/0.25 50/0.25 56/0.3 16/0.2 24/0.2 32/0.2 30/0.25 50/0.25 56/0.3 0.6 0.6 0.6 0.7 0.8 O.B 0.6 0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.6 0.7 0.8 0.8 0.6 0.6 0.6 0.7 0.8 0.8 Nominal thickness
  • 9. sales@kabelindo.co.id 7 Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable Cu/PVC/PVC 0.6/1 kV (NYY) Specification : SPLN 43-1 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41- 2: IEC 60502-1 Identification of core Light Blue 3. Outer Sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request. Applications: Indoor and outdoor induct installation or of laying in the ground where not sustain mechanical damage. Note : [re] round solid conductor [rm] Circular stranded conductor Packing : [D] Drum No. of cores and cross section area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max In Ground 0.1 second Insulation Min In Air 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 46.00 57.50 72.45 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 65.05 81.32 102.46 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 145.46 181.83 229.11 26 26 35 35 46 46 58 58 80 105 140 175 215 270 335 390 445 510 620 710 850 1000 1195 33 33 45 45 58 58 74 74 98 129 169 210 250 310 375 425 480 550 640 730 855 990 1126 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 104 108 112 117 128 133 137 144 158 178 209 229 257 288 333 360 400 443 499 553 616 686 763 50 52 63 67 87 92 110 117 163 227 336 437 562 768 1049 1280 1275 1959 2538 3157 3995 5075 6449 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.3 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 2.6 2.8 2.8 5.8 6 6.2 6.5 7.1 7.4 7.6 8 8.8 9.9 11.6 12.7 14.3 16 18.5 20 22.2 24.6 27.7 30.7 34.2 38.1 42.4 1 x 1.5 re 1 x 1.5 rm 1 x 2.5 re 1 x 2.5 rm 1 x 4 re 1 x 4 rm 1 x 6 re 1 x 6 rm 1 x 10 rm 1 x 16 rm 1 x 25 rm 1 x 35 rm 1 x50 rm 1 x 70 rm 1 x 95 rm 1 x 120 rm 1 x 150 rm 1 x 185 rm 1 x 240 rm 1 x 300 rm 1 x 400 rm 1 x 500 rm 1 x 630 rm
  • 10. www.kabelindo.co.id8 Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable Cu/PVC/PVC 0.6/1 kV (NYY) Specification : SPLN 43-1 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41- 2: IEC 60502-1 Identification of core (SPLN) Light Blue, Black (SNI IEC) Light Blue, Brown 3. Inner covering / filler : Extruded Polyvinyl Chloride (PVC) Black colour 4. Outer Sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request. Applications: Indoor and outdoor induct installation or of laying in the ground where not sustain mechanical damage. Note : [re] round solid conductor [rm] Circular stranded conductor Packing : [D] Drum No. of cores and cross section area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max In Ground 0.1 second Insulation Min In Air 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 500/D 500/D 500/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15A5 19.52 24.40 30.09 39 03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 21 21 29 29 38 38 48 48 66 90 120 150 180 230 275 320 379 430 510 590 27 27 36 36 47 47 59 59 78 102 134 160 187 230 280 320 355 409 472 525 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 194 200 209 218 239 250 257 272 302 340 401 441 499 565 655 715 787 875 992 1,094 159 168 196 209 269 289 333 359 485 657 959 1224 4578 2131 2905 3531 4321 5368 6964 8605 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2 2.1 2.2 2.4 2.6 2.7 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 10.8 11.1 11.6 12.1 13.3 13.9 14.3 15.1 16.8 18.9 22.3 24.5 27.7 31.4 36.4 39.7 43.7 48.6 55.1 60.8 2x1.5 re 2x1.5 rm 2x2.5 re 2x2.5 rm 2x4 re 2x4 rm 2x6 re 2x6 rm 2x10 rm 2x16 rm 2x25 rm 2x35 rm 2x50 rm 2x70 rm 2x95 rm 2x120 rm 2x150 rm 2x185 rm 2x240 rm 2x300 rm
  • 11. sales@kabelindo.co.id 9 Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable Cu/PVC/PVC 0.6/1 kV (NYY) Specification : SPLN 43-1 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shaped according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41- 2: IEC 60502-1 Identification of core : (SPLN) Identification of core : [SNI] Yellow/Green, Light Blue, Brown. 3. Inner covering / filler : Extruded Polyvinyl Chloride (PVC) Black colour 4. Outer Sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/ or special flame retardant. PVC sheath can be provided on request. Applications: Indoor and outdoor induct installation or of laying in the ground where not sustain mechanical damage. Note : [re] round solid conductor [rm] Circular stranded conductor (sm) sector shaped conductor Packing : [D] Drum System - i System - o Colour of insulation Light Blue, Yellow, BlackYellow/Green strip, Light Blue, Black No. of cores and cross section area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max In Ground 0.1 second Insulation Min In Air 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/0 500/D 500/D 500/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 18 18 25 25 34 34 44 44 60 80 105 130 160 200 245 285 325 370 435 600 24 24 32 32 41 41 52 52 69 89 116 138 165 205 245 285 315 355 415 535 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 202 209 218 227 252 263 272 286 320 360 425 468 455 515 589 639 706 788 887 990 181 191 229 245 319 342 401 433 596 822 1213 15.65 1898 2580 3485 4312 5300 6478 8491 10652 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2 2.1 2.2 2.3 2.5 2.7 3.1 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 11.2 11.6 12.1 12.6 14 14.6 15.1 15.9 17.8 20 23.6 26 25.3 28.6 32.7 35.5 39.2 43.8 49.3 55 3 x 1.5 re 3 x 1.5 rm 3 x 2.5 re 3 x 2.5 rm 3 x 4 re 3 x 4 rm 3 x 6 re 3 x 6 rm 3 x 10 rm 3 x 16 rm 3 x 25 rm 3 x 35 rm 3 x 50 sm 3 x 70 sm 3 x 95 sm 3 x 120 sm 3 x 150 sm 3 x 185 sm 3 x 240 sm 3 x 300 sm
  • 12. www.kabelindo.co.id10 Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable Cu/PVC/PVC 0.6/1 kV (NYY) Specification : SPLN 43-1 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shaped according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN 41- 2: IEC 60502-1 Identification of core : (SPLN) Identification Core : (SNI IEC) Yellow/Green Strip, Light Blue, Brown 3. Inner covering / filler : Extruded Polyvinyl Chloride (PVC) Black colour 4. Outer Sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request. Applications: Indoor and outdoor induct installation or of laying in the ground where not sustain mechanical damage. Note : [re] round solid conductor [rm] Circular stranded conductor (sm) sector shaped conductor Packing : [D] Drum System - i System - 0 Colour of insulation Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, Black No. of cores and cross section area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max In Ground 0.1 second Insulation Min In Air 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 500/D 500/D 500/D 0.17 0.17 0.29 0.29 0.46 0A6 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 18 18 25 25 34 34 44 44 60 80 105 130 160 200 245 285 325 370 435 500 24 24 32 32 41 41 52 52 69 89 116 138 165 205 245 285 315 355 415 465 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 216 223 234 245 272 284 293 310 349 392 466 515 540 614 697 767 833 940 1,053 1,177 213 224 273 292 385 413 490 527 743 1035 1541 1999 2498 3374 4536 5676 6910 8596 11087 13549 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.1 2.2 2.3 2.5 2.7 2.9 3.1 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 12 12.4 13 13.6 15.1 15.8 16.3 17.2 21 24 28 30 32 36 40 44 49 53 60 66 4 x 1.5 re 4 x 1.5 rm 4 x 2.5 re 4 x 2.5 rm 4 x 4 re 4 x 4 rm 4 x 6 re 4 x 6 rm 4 x 10 rm 4 x 16 rm 4 x 25 rm 4 x 35 rm 4 x 50 sm 4 x 70 sm 4 x 95 sm 4 x 120 sm 4 x 150 sm 4 x 185 sm 4 x 240 sm 4 x 300 sm
  • 13. sales@kabelindo.co.id 11 Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable Cu/PVC/PVC 0.6/1 kV (NYY) Specification : SPLN 43-1 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC) complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SPLN) Yellow/Green strip, Light Blue, Red, Yellow, Black (SNI IEC) : Yellow/Green strip, Light Blue, Black, Brown, Grey. 3. Inner covering / filler Extruded Polyvinyl Chloride (PVC) Black colour 4. Outer sheath Extruded Polyvinyl Chloride (PVC) Black colour, Anti termite and / or special flame retardant, PVC sheath can be provided on request. Applications: Indoor and outdoor induct installation or of laying in the ground where not sustain mechanical damage. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum No. of cores and cross section area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max In Ground 0.1 second Insulation Min In Air 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 18 18 25 25 34 34 44 44 60 80 105 130 160 24 24 32 32 41 41 52 52 69 89 116 138 165 50 50 50 50 50 50 50 50 50 40 40 40 30 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 230 239 252 263 293 308 319 335 380 428 509 567 655 255 268 329 352 470 505 602 650 912 1279 1914 2505 3273 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 12.8 13.3 14 14.6 16.3 17.1 17.7 18.6 21.1 23.8 28.3 31.5 36.4 5 x 1.5 re 5 x 1.5 rm 5 x 2.5 re 5 x 2.5 rm 5 x 4 re 5 x 4 rm 5 x 6 re 5 x 6 rm 5 x 10 rm 5 x 16 rm 5 x 25 rm 5 x 35 rm 5 x 50 rm
  • 14. www.kabelindo.co.id12 Copper Conductor PVC Insulated & PVC Sheathed non Armoured Control Cable Cu/PVC/PVC 0.6/1 kV (NYY) Specification : SPLN 43-1 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core (SPLN) (SNI IEC): Black, with White Number 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Applications: Indoor and outdoor induct : installation or of laying in the ground where not sustain mechanical damage. Note : [re] round solid conductor [rm] circular stranded conductor Packing : (D) Drum System - i System - 0 Colour of insulation Black with White numberYellow/Green strip, Black with White number No. of cores and cross section area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max In Ground 0.1 second Insulation Min In Air 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 13 13 12 12 12 12 11 11 11 11 10 10 9 9 9 9 8 8 8 8 8 8 8 8 8 8 17 17 16 16 15 15 14 14 13 13 12 12 12 12 11 11 11 11 11 11 11 11 11 11 11 11 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 261 270 279 288 313 326 322 335 337 351 351 365 367 383 385 401 421 439 443 463 491 513 576 601 594 623 324 341 362 381 434 458 480 506 542 572 599 632 670 707 728 768 821 866 970 1024 1226 1294 1585 1673 1815 1916 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 14.5 15 15.5 16 17.4 18.1 17.9 18.6 18.7 19.5 19.5 20.3 20.4 21.3 21.4 22.3 23.4 24.4 24.6 25.7 27.3 28.5 32 33.4 33 34.6 7x1.5 re 7x1.5 rm 8x1.5 re 8x1.5 rm 10x1.5 re 10x1.5 rm 12x1.5 re 12x1.5 rm 14x1.5 re 14x1.5 rm 16x1.5 re 16x1.5 rm 19x1.5 re 19x1.5 rm 21x1.5 re 21x1.5 rm 24x1.5 re 24x1.5 rm 30x1.5 re 30x1.5 rm 40x1.5 re 40x1.5 rm 52x1.5 re 52x1.5 rm 61x1.5 re 61x1.5 rm 3. Inner Covering / filler:
  • 15. sales@kabelindo.co.id 13 Copper Conductor PVC Insulated & PVC Sheathed non Armoured Control Cable Cu/PVC/PVC 0.6/1 kV (NYY) Specification : SPLN 43-1 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core (SPLN) (SNI IEC): Black, with White Number 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Applications: Indoor and outdoor induct : installation or of laying in the ground where not sustain mechanical damage. Note : [re] round solid conductor [rm] circular stranded conductor Packing : (D) Drum No. of cores and cross section area Nominal Thickness Insulation Outer Sheath (approx) (approx) Overall Diameter Weight of Cable Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor In Ground 0.1 second Insulation In Air 0.5 second 1.0 second sq.mm mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 21 21 18 18 17 17 16 16 15 15 14 14 13 13 12 12 11 11 11 11 11 11 11 11 11 11 26 26 23 23 21 21 20 20 18 18 17 17 17 17 16 16 15 15 14 14 14 14 14 14 14 14 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 284 297 304 319 344 362 355 373 369 389 387 407 405 425 425 448 466 491 491 518 549 581 644 682 666 704 421 450 471 505 570 611 637 682 724 777 804 863 907 974 989 1062 1118 1200 1335 1433 1718 1846 2220 2384 2552 2741 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.1 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 15.8 16.5 16.9 17.7 19.1 20.1 19.7 20.7 20.5 21.6 21.5 22.6 22.5 23.6 23.6 24.9 25.9 27.3 27.3 28.8 30.5 32.3 35.8 37.9 37 39.1 7x2.5 re 7x2.5 rm 8x2.5 re 8x2.5 rm 10x2.5 re 10x2.5 rm 12x2.5 re 12x2.5 rm 14x2.5 re 14x2.5 rm 16x2.5 re 16x2.5rm 19x2.5 re 19x2.5 rm 21x2.5 re 21x2.5 rm 24x2.5 re 24x2.5 rm 30x2.5 re 30x2.5 rm 40x2.5 re 40x2.5 rm 52x2.5 re 52x2.5 rm 61x2.5 re 61x2.5 rm 4. Outer sheath: System - i System - 0 Colour of insulation Black with White numberYellow/Green strip, Black with White number
  • 16. www.kabelindo.co.id14 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 4 1 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core (SPLN) Light Blue, Black ( SNI IEC ) Light Blue, Brown. 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Armour : A layer of galvanized flat steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/ or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Armour Flat Steel Size Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 9.09 12.73 18.18 25.46 34.55 43.84 54.55 67.28 87.28 109.10 120 150 180 230 275 320 379 430 510 590 134 160 187 230 280 320 355 409 472 525 40 40 30 30 30 30 20 20 20 20 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 448 448 549 621 706 765 844 932 1.044 1.154 1383 1709 2170 2846 3702 4423 5347 6501 8231 10081 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.5 2.7 2.8 24.9 27.1 30.5 34.5 39.2 42.5 46.9 51.8 58 64.1 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 2x25 rm 2x 35 rm 2x50 rm 2x70 rm 2x95 rm 2x120rm 2x150rm 2x185rm 2x240rm 2x300rm
  • 17. sales@kabelindo.co.id 15 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60902-1 : 2009 4. Armour : A layer of galvanized flat steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor [sm] sector shaped conductor Packing : [D] Drum System - i System - 0 Colour of insulation Light Blue, Yellow, BlackYellow/Green strip, Light Blue, Black Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core (SPLN) ( SNI IEC ) Yellow/Green Strip, Light Blue, Brown. 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour Armour Flat Steel Size Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor in Ground 0.1 second Insulation in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 80 105 130 160 200 245 285 325 370 435 500 89 116 138 165 205 245 285 315 355 415 465 40 40 40 30 30 30 30 20 20 20 20 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 407 472 515 506 563 641 691 760 842 941 1.033 1010 1695 2084 2403 3112 4151 5041 6121 7377 9536 11717 1.8 1.8 1.8 1.9 2.0 2.2 2.3 2.4 2.6 2.8 3.0 22.6 26.2 28.6 28.1 31.3 35.6 38.4 42.2 46.8 52.3 57.4 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 3 x16 rm 3 x 25 rm 3 x 35 rm 3 x 50 sm 3 x 70 sm 3 x 95 sm 3 x120 sm 3 x150 sm 3 x185 sm 3 x 240 sm 3 x 300 sm
  • 18. www.kabelindo.co.id16 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/PVC 0.6/1 kV (NYFGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SPLN) ( SNI IEC ) Yellow/Green Strip, Light Blue, Black, Brown. 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Armour : A layer of galvanized flat steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor [sm] sector shaped conductor Packing : [D] Drum System - i System - 0 Colour of insulation Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, Black Armour Flat Steel Size Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 500/D 500/D 250/D 250/D 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 1.63 2.60 48.79 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 80 80 105 130 160 200 245 285 325 370 435 500 69 89 116 138 165 205 245 285 315 355 415 465 50 40 40 40 30 30 30 30 20 20 20 20 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 349 392 466 515 541 614 697 767 833 940 1.053 1.177 1101 1455 2093 2602 3080 4093 5370 6563 7938 9756 12409 15104 1.8 1.8 1.8 1.9 2.0 2.1 2.3 2.4 2.6 2.8 3.0 3.2 23 26 30 33 35 38 43 47 51 56 62 68 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 4 x10 rm 4 x 16 rm 4 x 25 rm 4 x 35 rm 4 x 50 sm 4 x 70 sm 4 x 95 sm 4 x120 sm 4 x150 sm 4 x 185 sm 4 x 240 sm 4 x 300 sm
  • 19. sales@kabelindo.co.id 17 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SPLN) Yellow/Green Strip, Light Blue, Red, Yellow, Black. ( SNI IEC ) Yellow/Green Strip, Light Blue, Black, Brown, Grey. 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Armour : A layer of galvanized flat steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Armour Flat Steel Size Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/ mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1.15 1.84 2.88 4.03 5.75 1.63 2.60 4.07 5.69 8.13 3.64 5.82 9.09 12.73 18.18 60 80 105 130 160 69 89 116 138 165 50 40 40 40 30 1.83 1.15 0.727 0.524 0.387 434 482 563 625 715 1323 1750 2519 3158 4117 1.8 1.8 1.9 2.0 2.1 24.1 26.8 31.3 34.7 39.7 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 4 x 0.8 1.0 1.0 1.2 1.2 1.4 5 x10 rm 5 x 16 rm 5 x 25 rm 5 x 35 rm 5 x 50 sm
  • 20. www.kabelindo.co.id18 Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 4. Armour : A layer of galvanized flat steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Armour Flat Steel Size Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 13 13 12 12 11 11 11 11 10 10 10 10 9 9 9 9 9 8 8 8 8 9 8 8 8 8 17 17 16 16 15 15 14 14 13 13 12 12 12 12 11 11 11 11 11 11 11 11 11 11 11 11 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 335 346 355 365 391 407 414 428 432 445 450 461 468 479 486 499 508 527 540 565 607 634 677 707 711 743 727 777 792 848 929 997 1117 1199 1197 1287 1310 1382 1391 1504 1496 1611 1629 1766 1857 2020 2420 2635 2932 3190 3215 3518 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.8 1.8 1.8 1.8 1.9 1.8 1.8 1.8 1.8 1.9 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.1 18.6 19.2 19.7 20.3 21.7 22.6 23 23.8 24 24.7 25 25.6 26 26.6 27 27.7 28.2 29.3 30 31.4 33.7 35.2 37.6 39.3 39.5 41.3 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 440.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 7x1.5 re 7x1.5 rm 8x1.5 re 8x1.5 rm 10x1.5 re 10x1.5 rm 12x1.5 re 12x1.5 rm 14x1.5 re 14x1.5 rm 16x1.5 re 16x1.5 rm 19x1.5 re 19x1.5 rm 21x1.5 re 21x1.5 rm 24x1.5 re 24x1.5 rm 30x1.5 re 30x1.5 rm 40x1.5 re 40x1.5 rm 52x1.5 re 52x1.5 rm 61x1.5 re 61x1.5 rm Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SPLN) ( SNI IEC ) Black with White number 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour Colour of insulation System - i System - 0 Black with White numberYellow/Green strip, Black with White number
  • 21. sales@kabelindo.co.id 19 Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 4. Armour : A layer of galvanized flat steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum System - i System - 0 Colour of insulation Black with White numberYellow/Green strip, Black with White number Armour Flat Steel Size Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 21 21 18 18 17 17 16 16 15 15 14 14 13 13 12 12 11 11 11 11 11 11 11 11 11 11 26 26 23 23 21 21 20 20 18 18 17 17 17 17 16 16 15 15 14 14 14 14 14 14 14 14 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 335 371 378 392 432 454 443 463 457 481 484 499 495 520 515 544 547 574 585 639 671 711 749 778 790 833 848 918 928 1007 1228 1332 1317 1431 1421 1548 1561 1671 1675 1833 1800 1973 1980 2173 2280 2823 3167 3389 3704 4002 4121 4970 1.8 1.8 1.B 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.1 2.2 2.2 19.7 20.6 21 21.8 24 25.2 24.6 25.7 25.4 26.7 26.9 27.7 27.5 28.9 28.6 30.2 30.4 31.9 32.5 35.5 37.3 39.5 41.6 43.2 43.9 46.3 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 440.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 7x2.5 re 7x2.5 rm 8x2.5 re 8x2.5 rm 10x2.5 re 10x2.5 rm 12x2.5 re 12x2.5 rm 14;2.5 re 14x2.5 rm 16x2.5 re 16x2.5 rm 19x2.5 re 19x2.5 rm 21x2.5 re 21x2.5 rm 24x2.5 re 24x2.5 rm 30x2.5 re 30x2.5 rm 40x2.5 re 40x2.5 rm 52x2.5 re 52x2.5 rm 61x2.5 re 61x2.5 rm Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 (SNI IEC) Black with White number 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour
  • 22. www.kabelindo.co.id20 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC :60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core (SPLN) Light Blue, Black ( SNI IEC ) Light Blue, Brown 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Armour Round Steel Wire Diameter Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.28 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.45 67.28 8728 109.10 21 21 29 29 38 38 48 48 66 90 120 150 180 230 275 320 375 430 510 590 27 27 36 36 47 47 59 59 78 102 134 160 187 230 280 320 355 409 472 525 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 250 257 263 274 295 306 324 340 374 421 479 520 605 662 760 837 911 1,004 1,120 1,233 374 375 406 430 503 536 674 734 908 1296 1688 2030 2812 3430 4470 5648 6650 8007 9952 11918 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.5 2.7 2.8 13.9 14.3 14.6 15.2 16.4 17 18 18.9 20.8 23.4 26.6 2E9 33.6 36.8 42.2 46.5 50.6 55.8 62.2 58.5 0.9 0.9 0.9 0.9 0.9 02 125 1.25 1.25 1.6 1.6 1.6 2.0 2.0 2.0 2.5 2.5 2.5 2.5 2.5 0.8 0.8 0.8 as in 10 10 1.0 1.0 in 12 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 2x1.5 re 2x1.5 rm 2x2.5 re 2x2.5 rm 2x4 re 2x4 rrn 2x6 re 2x6 rm 2x10 rm 2x16 rm 2x25 rm 2x35 rm 2x50 rm 2x70 rm 2x95 rm 2x120 rm 2x150 rm 2x185 rm 2x240 rm 2x300 rm
  • 23. sales@kabelindo.co.id 21 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SPLN) (SNI IEC) Yellow/Green Strip, Light Blue,Brown. 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor (sm) sector shaped conductor Packing : [D] Drum System - i System - o Colour of insulation Light Blue, Yellow, BlackYellow/Green strip, Light Blue, Brown Armour Flat Steel Size Thickness of Insulation No. of cores and cross section Thickness of outer sheath Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 1128 15.45 19.52 24.40 30.09 39 03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.45 67.28 87.28 109.10 18 18 25 25 34 34 44 44 60 80 105 130 160 200 245 285 325 370 435 500 24 24 32 32 41 41 52 52 69 89 116 138 165 205 245 285 315 355 415 465 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 257 266 274 284 320 333 338 355 392 441 506 369 589 661 738 787 880 945 1,042 1,124 390 410 451 479 655 699 762 819 1044 1416 1894 2321 2784 3806 4882 5853 7407 8774 11036 13137 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.2 2.3 2.4 2.6 2.8 3.0 14.3 14.8 15.2 15.8 17.8 18.5 18.8 19.7 21.8 24.5 28.1 30.5 32.7 36.7 41 43.7 48.9 52.5 57.9 62.47 0.9 0.9 0.9 0.9 0.9 0.9 1.25 1.25 1.25 1.6 1.6 1.6 2.0 2.0 2.0 2.5 2.5 2.5 2.5 2.5 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 3x1.5 re 3x1.5 rm 3x2.5 re 3x2.5 rm 3x4 re 3x4 rm 3x6 re 3x6 rm 3x10 rm 3x16 rm 3x25 rm 3x35 rm 3x50 sm 3x70 sm 3x95 sm 3x120 sm 3x150 sm 3x185 sm 3x240 sm 3x300 sm Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Annealed plain copper round solid or round circular stranded 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath:
  • 24. www.kabelindo.co.id22 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor (sm) sector shaped conductor Packing : [D] Drum System - i System - o Colour of insulation Light Blue, Red, Yellow, BlackYellow/Green strip, Light Blue, Yellow, Black Armour Round Steel Wire Diameter (nom) Thickness of Insulation (nom) No. of cores and cross section area Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx) Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0A6 0A6 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.45 67.28 87.28 109.10 18 18 25 25 34 34 44 44 60 80 105 130 160 200 245 285 325 370 435 500 24 24 32 32 41 41 52 52 69 89 116 138 165 205 245 285 315 355 415 465 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 274 281 288 301 338 355 374 378 432 473 547 592 610 697 790 868 945 1,030 1,157 1,305 433 455 515 538 740 790 870 925 1317 1548 2241 2933 2934 4148 5489 7163 8637 10354 13347 16702 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.1 2.3 2.4 2.6 2.8 3.0 3.2 15.2 15.6 16 16.7 18.8 19.7 20.8 21 24 26.3 30A 32.9 33.9 38.7 43.9 48.2 52.5 57.2 64.3 72.5 0.9 0.9 0.9 0.9 0.9 0.9 1.25 1.25 1.25 1.6 1.6 1.6 2.0 2.0 2.0 2.5 2.5 2.5 2.5 2.5 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 4x1.5 re 4x1.5 rm 4x2.5 re 4x2.5 rm 4x4 re 4x4 rm 4x6 re 4x6 rm 4x10 rm 4x16 rm 4x25 rm 4x35 rm 4x50 sm 4x70 sm 4x95 sm 4x120 sm 4x150 sm 4x185 sm 4x240 sm 4x300 sm Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SPLN) (SNI IEC) Yellow/Green Strip, Light Blue, Black, Brown. 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour
  • 25. sales@kabelindo.co.id 23 Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SPLN) Yellow/Green Strip, Light Blue, Red, Yellow, Black ( SNI IEC ) Yellow/Green Strip, Light Blue, Black, Brown, Grey 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Armour Round Steel Wire Diameter (nom) Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx) Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.96 4.03 5.75 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.15 5.69 8.13 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 18 18 25 25 34 34 44 44 60 80 105 130 160 24 24 32 32 41 41 52 52 69 89 116 138 165 50 50 50 50 50 50 50 50 50 40 40 40 30 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 288 297 319 333 360 378 385 405 463 509 598 673 774 484 509 647 687 839 897 996 1069 1527 1928 2641 3520 4921 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.1 16 16.5 17.7 18.5 20 21 21.4 22.5 25.7 28.3 33.2 37.4 43 0.9 0.9 0.9 1.25 1.25 1.25 1.25 1.25 1.6 1.6 1.6 2.0 2.0 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1A 5x1.5 re 5x1.5 rm 5x2.5 re 5x2.5 rm 5x4 re 5x4 rm 5x6 re 5x6 rm 5x10 rm 5x16 rm 5x25 rm 5x35 rm 5x50 rm Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Annealed plain copper round solid or round circular stranded 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape. 5. Outer sheath:
  • 26. www.kabelindo.co.id24 Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 System - i System - 0 Colour of insulation Black with White numberYellow/Green strip, Black with White number 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Armour Round Steel Wire Diameter (nom) Thickness of Insulation (nom) No. of cores and cross section area Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx) Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 13 13 12 12 11 11 11 11 10 10 10 10 9 9 9 9 8 8 8 8 8 8 8 8 8 8 17 17 16 16 15 15 14 14 13 13 12 12 12 12 11 11 11 11 11 11 11 11 11 11 11 11 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 335 346 355 365 391 407 414 428 432 445 450 461 468 479 486 499 508 527 540 565 607 634 677 707 711 743 727 777 792 848 929 997 1117 1199 1197 1287 1310 1382 1391 1504 1496 1611 1629 1766 1857 2020 2420 2635 2932 3190 3215 3518 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.1 2.1 2.1 2.1 18.6 19.2 19.7 20.3 21.7 22.6 23 23.8 24 24.7 25 25.6 26 26.6 27 27.7 28.2 29.3 30 31.4 33.7 35.2 37.6 39.3 39.5 41.3 1.25 1.25 1.25 1.25 1.25 1.25 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 7x1.5 re 7x1.5 rm 8x1.5 re 8x1.5 rm 10x1.5 re 10x1.5 rm 12x1.5 re 12x1.5 rm 14x1.5 re 14x1.5 rm 16x1.5 re 16x1.5 rm 19x1.5 re 19x1.5 rm 21x1.5 re 21x1.5 rm 24x1.5 re 24x1.5 rm 30x1.5 re 30x1.5 rm 40x1.5 re 40x1.5 rm 52x1.5 re 52x1.5 rm 61x1.5 re 61x1.5 rm Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) 4. Armour :4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core (SPLN) (SNI IEC) : Black with White number 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour
  • 27. sales@kabelindo.co.id 25 Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Armour Round Steel Wire Diameter Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor in Ground 0.1 second Insulation in Air 0.5 second 1.0 second mmmmsq.mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 21 21 18 18 17 17 16 16 15 15 14 14 13 13 12 12 11 11 11 11 11 11 11 11 11 11 26 26 23 23 21 21 20 20 18 18 17 17 17 17 16 16 15 15 14 14 14 14 14 14 14 14 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 335 371 378 392 432 454 443 463 457 481 484 499 495 520 515 544 547 574 585 639 671 711 749 778 790 833 848 918 928 1007 1228 1332 1317 1431 1421 1548 1561 1671 1675 1833 1800 1973 1980 2173 2280 2823 3167 3389 3704 4002 4121 4970 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 1.9 1.9 2.1 2.1 2.2 2.2 2.3 2.3 19.7 20.6 21 21.8 24 25.2 24.6 25.7 25.4 26.7 26.9 27.7 27.5 28.9 28.6 30.2 30.4 31.9 32.5 35.5 37.3 39.5 41.6 43.2 43.9 46.3 1.25 1.25 1.25 1.25 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 2.5 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 7x2.5 re 7x2.5 rm 8x2.5 re 8x2.5 rm 10x2.5 re 10x2.5 rm 12x2.5 re 12x2.5 rm 14x2.5 re 14x2.5 rm 16x2.5 re 16x2.5 rm 19x2.5 re 19x2.5 rm 21x2.5 re 21x2.5 rm 24x2.5 re 24x2.5 rm 30x2.5 re 30x2.5 rm 40x2.5 re 40x2.5 rm 52x2.5 re 52x2.5 rm 61x2.5 re 61x2.5 rm 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/ or special flame retardant, PVC sheath can be provided on request. Applications: For general purpose power distribution in dry or wet location, best suitable for direct burying in ground. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum System - i System - 0 Colour of insulation Black with White numberYellow/Green strip, Black with White number Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Specification : SPLN 43-2 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 4. Armour : A layer of galvanized round steel wires with a counter helix layer of galvanized steel tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/ or special flame retardant, PVC sheath can be provided on request. Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core (SPLN) (SNI IEC) : Black with White number 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour
  • 28. www.kabelindo.co.id26 Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Specification : SNI IEC 60502-1: 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SNI IEC) : Light Blue, Brown 3. Inner sheath: Polyvinyl Chloride [PVC], Black colour 4. Shield: Hellically copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Applications: For indoor installations, in power and switching stations. As un- derground cable, for difficult installation where the low weight is particularly advantageous. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Thickness of Insulation (nom) Thickness of Copper tape screened No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 21 21 29 29 38 38 48 48 66 90 120 150 180 230 280 320 375 430 510 590 27 27 36 36 47 47 59 59 78 102 134 180 210 260 315 320 355 409 472 525 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 218 223 230 241 261 274 297 326 364 425 464 526 589 691 749 819 911 909 1,031 1,139 218 231 263 280 348 369 417 445 582 771 1095 1368 1748 2336 3159 3807 4647 5756 7366 9117 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.2 2.3 2.4 2.6 2.8 3.0 12.1 12A 12.8 13.4 14.5 15.2 16.5 18.1 20.2 23.6 25.8 29.2 32.7 38.4 41.6 45.5 50.6 53.5 57.3 63.3 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 2x1.5 re 2x1.5 rm 2x2.5 re 2x2.5 rm 2x4 re 2x4 rm 2x6 re 2x6 rm 2x10 rm 2x16 rm 2x25 rm 2x35 rm 2x50 rm 2x70 rm 2x95 rm 2x120 rm 2x150 rm 2x185 rm 2x240 rm 2x300 rm Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Annealed plain copper round solid or round circular stranded or 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Applications:
  • 29. sales@kabelindo.co.id 27 Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Specification : SNI IEC 60902-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SNI IEC) : Yellow/Green Strip, Light Blue, Brown 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Shield: Hellically copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For indoor installations, in power and switching stations. As underground cable, for difficult installation where the low weight is particularly advantageous. Note: (re) round solid conductor (rm) circular stranded conductor (sm) sector shaped conductor Packing : [D] Drum Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable Thickness of Copper tape screened Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Standard delivery lengthConductor Max in Ground 0.1Insulation Min in Air 0.5 1.0 mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0A6 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25A6 34.55 43.64 54.55 67.28 87.28 109.10 18 18 25 25 34 34 44 44 60 80 105 130 160 200 245 285 325 370 435 500 24 24 32 32 41 41 52 52 69 89 116 138 165 205 245 285 315 355 415 465 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 223 232 239 250 275 284 295 310 344 385 445 495 517 544 623 680 743 821 922 1,030 246 262 296 323 398 432 492 524 698 940 1359 1720 2018 2671 3641 4478 5486 6693 8727 10869 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.2 2.3 2.4 2.6 2.8 3.0 12.4 12.9 13.3 13.9 15.3 15.8 16.4 17.2 19.1 21.4 24.7 27.5 28.7 30.2 34.6 37.8 41.3 45.6 51.2 57.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1A 1.6 1.6 1.8 2.0 2.2 2.4 3x1.5 re 3x1.5 rrn 3x2.5 re 3x2.5 rm 3x4 re 3x4 rm 3x6 re 3x6 rm 3x10 rm 3x16 rm 3x25 rm 3x35 rm 3x50 sm 3x70 sm 3x95 sm 3x120 sm 3x150 sm 3x185 sm 3x240 sm 3x300 sm Conductor Short Circuit Current Capacity at Specification : SNI IEC 60902-1 : 2009 Annealed plain copper round solid or round circular stranded or Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request.
  • 30. www.kabelindo.co.id28 Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Specification : SNI IEC 60502-1: 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core: (SNI IEC) : Yellow/Green Strip, Light Blue, Black, Brown 3.Inner covering / filler: Extruded Polyvinyl Chloride (PVC), Black colour 4. Shield: Hellically copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Applications: For indoor installations, in power and switching stations. As underground cable, for difficult installation where the low weight is particularly advantageous. Note : [re] round solid conductor [rm] circular stranded conductor [sm) sector shaped conductor Packing : [D] Drum Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Annealed plain copper round solid or round circular stranded or Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Thickness of Copper tape screened Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 024 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 18 18 25 25 34 34 44 44 60 80 105 130 160 200 245 285 325 370 435 500 24 24 32 32 41 41 52 52 69 89 116 138 165 205 245 285 315 355 415 465 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 236 241 256 266 293 308 317 333 367 416 490 544 572 643 734 803 866 968 1.087 1.202 281 296 348 373 470 509 585 627 847 1158 1683 2452 2640 3519 4717 5879 7135 8847 11363 13858 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.1 2.3 2.4 2.6 2.8 3.0 3.2 13.1 13.4 14.2 14.8 16.3 17.1 17.6 18.5 20.4 23.1 27.2 30.2 31.8 35.7 40.8 44.6 48.1 53.8 60.4 66.8 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 4x1.5 re 4x1.5 rm 4x2.5 re 4x2.5 rm 4x4 re 4x4 rm 4x6 re 4x6 rm 4x10 rm 4x16 rm 4x25 rm 4x35 rm 4x50 sm 4x70 sm 4x95 sm 4x120 sm 4x150 sm 4x185 sm 4x240 sm 4x300 sm
  • 31. sales@kabelindo.co.id 29 Specification : SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : (SNI IEC) : Yellow/Green strip, Light Blue, Black, Brown, Grey 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Shield: Hellically copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: For indoor installations, in power and switching stations. As un- derground cable, for difficult installation where the low weight is particularly advantageous. Note : (re) round solid conductor (rm) circular stranded conductor Packing : [D] Drum Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable Thickness of Copper tape screened Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.17 0.17 0.29 0.29 0A6 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 18 18 25 25 34 34 44 44 60 80 105 130 160 24 24 32 32 41 41 52 52 69 89 116 138 165 50 50 50 50 50 50 50 50 50 40 40 40 30 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 256 265 279 292 313 333 340 356 403 454 535 587 680 327 345 408 435 564 606 708 761 1036 1415 2079 2685 3497 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 14.2 14.7 15.5 16.2 17.4 18.5 18.9 19.8 22.4 25.2 29.7 32.6 37.8 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 14 5x1.5 re 5x1.5 rm 5x2.5 re 5x2.5 rm 5x4 re 5x4 rm 5x6 re 5x6 rm 5x10 rm 5x16 rm 5x25 rm 5x35 rm 5x50 rm Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Specification : SNI IEC 60502-1 : 2009 Annealed plain copper round solid or round circular stranded or Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request.
  • 32. www.kabelindo.co.id30 Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Control Cable Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Specification : SNI IEC 60502-1: 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or according to SPLN 41 - 1; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core: Black with White printed number 3.Inner covering /filler: Extruded Polyvinyl Chloride (PVC), Black colour 4. Shield: Hellically copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Applications: For indoor installations, in power and switching stations. As un- derground cable, for difficult installation where the low weight is particularly advantageous. Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Thickness of Copper tape screened Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 0.55 13 13 12 12 11 11 11 11 10 10 10 10 9 9 9 9 8 8 8 8 8 8 8 8 8 8 17 17 16 16 15 15 14 14 13 13 12 12 12 12 11 11 11 11 11 11 11 11 11 11 11 11 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 12.1 268 279 290 297 328 335 337 346 349 364 367 374 382 392 400 410 428 450 455 481 497 529 572 601 607 634 357 372 394 418 475 496 518 545 586 613 642 675 718 757 778 820 872 928 1026 1085 1288 1356 1656 1752 1893 1990 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 14.9 15.5 16.1 16.5 18.2 18.6 18.7 19.2 19.4 20.2 20.4 20.8 21.2 21.8 22.2 22.8 23.8 25 25.3 26.7 27.6 29A 31.8 33.4 33.7 35.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 7x1.5 re 7x1.5 rm 8x1.5 re 8x1.5 rm 10x1.5 re 10x1.5 rm 12x1.5 re 12x1.5 rm 14x1.5 re 14x1.5 rm 16x1.5 re 16x1.5 rm 19x1.5 re 19x1.5 rm 21x1.5 re 21x1.5 rm 24x1.5 re 24x1.5 rm 30x1.5 re 30x1.5 rm 40x1.5 re 40x1.5 rm 52x1.5 re 52x1.5 rm 61x1.5 re 61x1.5 rm Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Annealed plain copper round solid or round circular stranded or Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request
  • 33. sales@kabelindo.co.id 31 Thickness of Copper tape screened Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 18 18 17 17 16 16 15 15 14 14 13 13 13 13 12 12 11 11 11 11 11 11 11 11 11 11 23 23 21 21 20 20 18 18 17 17 17 17 16 16 15 15 14 14 14 14 14 14 14 14 14 14 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 7.41 741 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 741 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 7.41 284 299 308 329 347 369 373 387 392 405 407 421 425 446 452 464 472 482 509 544 571 603 673 695 731 745 458 486 509 545 617 656 682 432 775 826 854 918 962 1027 1055 1136 1210 1292 1426 1535 1840 1973 2358 2534 2701 2895 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.1 2.1 2.1 2.1 15.8 16.6 17.1 18.3 19.3 20.5 20.7 21.5 21.8 22.5 22.6 23.4 23.6 24.8 25.1 25.8 26.2 26.8 28.3 30.2 31.7 33.5 37.4 38.6 40.6 41.4 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 7x2.5 re 7x2.5 rm 8x2.5 re 8x2.5 rm 10x2.5 re 10x2.5 rrn 12x2.5 re 12x2.5 rm 14x2.5 re 14x2.5 rm 16x2.5 re 16x2.5 rm 19x2.5 re 19x2.5 rm 21x2.5 re 21x2.5 rrn 24x2.5 re 24x2.5 rm 30x2.5 re 30x2.5 rm 40x2 5 re 40x2.5 rm 52)(2.5 re 52x2.5 rm 61x2.5 re 61x2.5 rrn Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Specification : SNI IEC 60502-1:2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or according to SPLN 41 - 1; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : Black with White printed number 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Shield: Hellically copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/orspecial flame retardant, PVC sheath can be provided on request. Applications: For indoor installations, in power and switching stations. As underground cable, for difficult installation where the low weight is particularly advantageous. Note : (re) round solid conductor (rm) circular stranded conductor Packing : [D] Drum Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Control Cable Specification : SNI IEC 60502-1:2009 Annealed plain copper round solid or round circular stranded or Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/orspecial flame retardant, PVC sheath can be provided on request.
  • 34. www.kabelindo.co.id32 Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable Cu/PVC/CWS/PVC 0.6/1 kV (NYCY) Specification: SPLN 43-4 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core: (SPLN) Light Blue and Brown Light Blue and Red or Light Blue and Yellow or Light Blue and Black (SNI IEC) : Light Blue and Brown 3.Inner sheat: Polyvinyl Chloride (PVC), Black colour 4. Screen: Annealed copper wire with transverse helix of Annealed copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request Applications: Indoor, in ducts, in the open, underground, if mechanical damage is not expected Note : [re] round solid conductor [rm] circular stranded conductor Packing : [D] Drum Cross section of concentric shield Thickness of Insulation (nom) No. of cores and cross section Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance at 20°C Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor Max in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second sq.mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm.km A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 1.45 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.55 67.28 87.28 109.10 21 21 29 29 38 38 48 48 66 90 120 150 180 230 280 320 375 430 510 590 27 27 36 36 47 47 59 59 78 102 134 180 210 260 315 320 355 409 472 525 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 243 250 261 292 302 310 320 326 364 396 461 500 563 644 727 785 873 968 1,091 1,215 230 242 281 290 370 395 454 485 658 891 1207 1476 1928 2605 3557 4376 5208 6546 8368 10385 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.2 2.3 2.4 2.6 2.8 3.0 13.5 13.9 14.5 16.2 16.8 17.2 17.8 18.1 20.2 22 25.6 27.8 31.3 35.8 40.4 43.6 48.5 53.8 60.6 67.5 1.5 1.5 2.5 2.5 4 4 6 6 10 16 16 16 25 35 50 70 70 95 120 150 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 14 1.6 1.6 1.8 2.0 2.2 2.4 2x1.5 re/1.5 2x1.5 rm/1.5 2x2.5 re/2.5 2x2.5 rm/2.5 2x4 re/4 2x4 rm/4 2x6 re/6 2x6 rm/6 2x10 rm/10 2x16 rm/16 2x25 rm/16 2x35 rm/16 2x50 rm/25 2x70 rm/35 2x95 rm/50 2x120 rm/70 2x150 rm/70 2x185 rm/95 2x240 rm/120 2x300 rm/150 Cu/PVC/CWS/PVC 0.6/1 kV (NYCY) Annealed plain copper round solid or round circular stranded or Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or special flame retardant. PVC sheath can be provided on request
  • 35. sales@kabelindo.co.id 33 Cu/PVC/CWS/PVC 0.6/1 kV (NYCY) Specification : SPLN 43-4 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Constructions: 1. Conductor: Annealed plain copper round solid or round circular stranded or sector shape according to SPLN 41 - 1 ; IEC 60228 2. Insulation: Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : IEC 60502-1 Identification of core : Light Blue, Red, Yellow or Light Blue, Red, Black or Light Blue, Yellow, Black (SNI IEC) : Yellow/Green strip, Light Blue, Brown 3. Inner Covering / filler: Extruded Polyvinyl Chloride [PVC], Black colour 4. Shield: Annealed copper wire with transverse helix of Annealed copper tape 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Applications: Indoor, in ducts, in the open, underground, if mechanical damage is not expected. Note : (re) round solid conductor (rm) circular stranded conductor (sm) sector shaped conductor Packing : [D] Drum Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable Specification : SPLN 43-4 : 1994 IEC 60502-1 : 2004 SNI IEC 60502-1 : 2009 Annealed plain copper round solid or round circular stranded or Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or special flame retardant, PVC sheath can be provided on request. Cross section of concentric shield Thickness of Insulation (nom) No. of cores and cross section area Thickness of outer sheath (nom) Overall Diameter (approx) Weight of Cable (approx] Minimum bending radius DC. Resistance Current Carrying Capacity at 30°C Conductor Short Circuit Current Capacity at Standard delivery lengthConductor in Ground 0.1 second Insulation Min in Air 0.5 second 1.0 second sq.mmmmsq.mm mm mm kg/km mm Ohm/km AM.Ohm. A kA kA kA m 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 1000/D 500/D 500/D 250/D 250/D 0.17 0.17 0.29 0.29 0.46 0.46 0.69 0.69 1.15 1.84 2.88 4.03 5.75 8.05 10.93 13.80 17.25 21.28 27.60 34.50 0.24 0.24 0.41 0.41 0.65 0.65 0.98 0.98 1.63 2.60 4.07 5.69 8.13 11.38 15.45 19.52 24.40 30.09 39.03 48.79 0.55 0.55 0.91 0.91 145 1.45 2.18 2.18 3.64 5.82 9.09 12.73 18.18 25.46 34.55 43.64 54.45 67.28 87.28 109.10 18 18 25 25 34 34 44 44 60 80 105 130 160 200 245 285 325 370 435 500 24 24 32 32 41 41 52 52 69 89 116 138 165 205 245 285 315 355 415 465 50 50 50 50 50 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 12.1 12.1 7.41 7.41 4.61 4.61 3.08 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 253 259 268 279 304 315 328 344 383 418 482 531 535 583 659 724 787 889 986 1,103 260 271 322 339 427 456 535 568 787 1068 1476 1438 2216 2985 4065 5073 6082 7516 9768 12186 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.2 2.3 24 2.6 2.8 3.0 14.1 144 14.9 15.5 16.9 17.5 18.2 19.1 21.3 23.2 26.8 29.5 29.7 324 36.6 40.2 43.7 494 54.8 61.3 1.5 1.5 2.5 2.5 4 4 6 6 10 16 16 16 25 35 50 70 70 95 120 150 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 3x1.5 re/1.5 3x1.5 rm/1.5 3x2.5 re/2.5 3x2.5 rm/2.5 3x4 re/4 3x4 rm/4 3x6 re/6 3x6 rm/6 3x10 rm/10 3x16 rm/16 3x25 rm/16 3x35 rm/16 3x50 sm/25 3x70 sm/35 3x95 sm/50 3x120 sm/70 3x150 sm/70 3x185 sm/95 3x240 sm/120 3x300 sm/150