SlideShare a Scribd company logo
1 of 16
CATHODE RAY
TUBE
Dr. J. Revathi
Assistant Professor
Department of Biomedical Engineering
Dr. N.G.P Institute of Technology
CATHODE RAY TUBE
• The Cathode Ray Tube (CRT) is a vacuum tube containing an electron gun (a source
of electrons or electron emitter) and a fluorescent screen used to view images.
• It has a mean to accelerate and deflect the electron beam onto the fluorescent
screen to create the images.
• The image may represent Electrical waveforms in oscilloscope, pictures
(television, computer monitor), radar targets.
• CRTs have largely superseded by modern technologies such as, LCD, LED, etc,
which offer lower manufacturing and distribution cost.
PRINCIPLE OF CRT
• The Cathode Ray Tube (CRT) is the device that displays images upon a
screen using electron beams.
• It is a vacuum sealed tube to avoid air resistance.
• The electrons are first created at the back of the CRT by an electron gun.
• The electrons are shot off the gun at a high velocity and travel through a
magnetic field, which steers them in a certain direction
• The electrons then pass through a filter (shadow mask)
and collide with a phosphor screen, to which they transfer their
energy and cause the screen to glow.
• Through specific direction of these electron beams, images are
created and displayed on the screen.
CRT
THREE MAIN PARTS
• Electron gun
• Deflecting plates
• Fluorsecent screen
ELECTRON GUN
The electron gun produces the electron beam that travels through
the CRT.
The electron gun consists of
•cathode
•filament
•accelerating anode
FUNCTION OF CATHODE AND
ANODE
• The filament is insulated coil of tungsten located inside the cathode
• The current is applied to this coil to heat it.
• When the cathode is heated, the electrons on the cathode released.
• The cathode creates an electron cloud (emits electrons) whose electrons are
extracted, accelerated and focused into an electron beam.
• The anode serves only to provide the accelerating voltage for the electrons and not as
the electron collector.
DEFLECTING PLATES
• The CRT can use either electrostatic or magnetic deflection. so that the
beam of electrons can have its direction altered, allowing the light spot to
appear anywhere on the face of the tube.
• The cathode-ray-tube deflection system is made up of two pairs of parallel
plates known as the vertical and horizontal deflection plates.
• The plates are made up of copper or aluminium.
ELECTROSTATIC DEFLECTION
SYSTEM
• Due to this, strong electric field is produced between the
plates.
• When electron beam enters in this field, it is deflected
towards the plate which is positive.
• So the path of beam becomes parabolic.
• Then the beam comes out of this field in straight line and
strikes on the screen at a particular point on the screen.
MAGNETIC DEFLECTION SYSTEM
• In this system, electron beam is deflected using external
magnetic field.
• To create alternating magnetic field two pairs of deflection
coils, known as yoke, are fitted on the neck of CRT.
• The pair of vertical deflection coils is connected to y-input of
CRO
• The pair of horizontal deflection coils is connected to
internal sawtooth wave or external signal at x-input.
CRT SCREEN
• The CRT screen consists of two main parts: the phosphor screen and the shadow
mask.
• The phosphor screen turns the electron beam into light, and the shadow mask
organizes the beam on the screen.
• It contains millions of tiny red, green, and blue phosphor dots that glow when struck
by an electron beam that travels across the screen to create a visible image.
• The electrons are negative and the screen gives a positive charge so the screen
glows.
•
PHOSPHOR PERSISTENCE
• The various phosphors are available depending upon the needs of the measurement or display
application.
• The brightness, color, and persistence of the illumination depends upon the type of phosphor
used on the CRT screen.
• Phosphors are available with persistence's ranging from less than one microsecond to several
seconds.
• For visual observation of brief transient events, a long persistence phosphor may be desirable.
• For events which are fast and repetitive, or high frequency, a short-persistence phosphor is
generally preferable.
ADVANTAGES OF CRT
• The cathode rayed tube can easily increase the monitor’s brightness by reflecting the
light.
• They produce more colours.
• The Cathode Ray Tube monitors have lower price rate than the LCD display or Plasma
display.
• The quality of the image displayed on a Cathode Ray Tube is superior to the LCD and
Plasma monitors.
• The contrast features of the cathode ray tube monitor are considered highly excellent.
DISADVANTAGES OF CRT
• The electromagnetic fields emitted by CRT monitors constitute a health
hazard to the functioning of living cells.
• CRTs emit a small amount of X-ray band radiation which can result in a
health hazard.
• Constant refreshing of CRT monitors can result in headache.
• CRTs operate at very high voltage which can overheat system or result in
an implosion
Introduction   to   cathode Ray Tube.pptx

More Related Content

Similar to Introduction to cathode Ray Tube.pptx

2- devices crt computer graphics and multimedia.ppt
2- devices crt computer graphics and multimedia.ppt2- devices crt computer graphics and multimedia.ppt
2- devices crt computer graphics and multimedia.pptKumarVaibhav100
 
Cathode Ray Oscilloscope
Cathode Ray OscilloscopeCathode Ray Oscilloscope
Cathode Ray OscilloscopeKetan Nayak
 
Photoelectric transducers and its classification
Photoelectric transducers and its classificationPhotoelectric transducers and its classification
Photoelectric transducers and its classificationkaroline Enoch
 
cathode ray tube
cathode ray tubecathode ray tube
cathode ray tubewasim liam
 
Scanning and transmission electroscopy.pptx
Scanning and transmission electroscopy.pptxScanning and transmission electroscopy.pptx
Scanning and transmission electroscopy.pptxNirmal P J
 
WORKING PRINCIPLE OF SEM.pptx
WORKING PRINCIPLE OF SEM.pptxWORKING PRINCIPLE OF SEM.pptx
WORKING PRINCIPLE OF SEM.pptxjunaid syed
 
Detectors used in array spectrophotometer
Detectors used in  array spectrophotometerDetectors used in  array spectrophotometer
Detectors used in array spectrophotometersuriyapriya kamaraj
 
Cathode ray tube
Cathode ray tubeCathode ray tube
Cathode ray tubeBCET
 
Crt
CrtCrt
CrtBCET
 
2018 HM-Transmission electron microscope
2018 HM-Transmission electron microscope2018 HM-Transmission electron microscope
2018 HM-Transmission electron microscopeHarsh Mohan
 

Similar to Introduction to cathode Ray Tube.pptx (20)

2- devices crt computer graphics and multimedia.ppt
2- devices crt computer graphics and multimedia.ppt2- devices crt computer graphics and multimedia.ppt
2- devices crt computer graphics and multimedia.ppt
 
Cathode Ray Oscilloscope
Cathode Ray OscilloscopeCathode Ray Oscilloscope
Cathode Ray Oscilloscope
 
cr srms1.pptx
cr srms1.pptxcr srms1.pptx
cr srms1.pptx
 
Photoelectric transducers and its classification
Photoelectric transducers and its classificationPhotoelectric transducers and its classification
Photoelectric transducers and its classification
 
cathode ray oscilloscope
cathode ray oscilloscopecathode ray oscilloscope
cathode ray oscilloscope
 
Cathode ray tube technology
Cathode ray tube technologyCathode ray tube technology
Cathode ray tube technology
 
cathode ray tube
cathode ray tubecathode ray tube
cathode ray tube
 
Scanning and transmission electroscopy.pptx
Scanning and transmission electroscopy.pptxScanning and transmission electroscopy.pptx
Scanning and transmission electroscopy.pptx
 
Crt display
Crt displayCrt display
Crt display
 
WORKING PRINCIPLE OF SEM.pptx
WORKING PRINCIPLE OF SEM.pptxWORKING PRINCIPLE OF SEM.pptx
WORKING PRINCIPLE OF SEM.pptx
 
Detectors used in array spectrophotometer
Detectors used in  array spectrophotometerDetectors used in  array spectrophotometer
Detectors used in array spectrophotometer
 
8259731.ppt
8259731.ppt8259731.ppt
8259731.ppt
 
Sem mahfooz
Sem mahfoozSem mahfooz
Sem mahfooz
 
Cathode ray tube
Cathode ray tubeCathode ray tube
Cathode ray tube
 
Video DIsplay Technologies
Video DIsplay TechnologiesVideo DIsplay Technologies
Video DIsplay Technologies
 
Crt
CrtCrt
Crt
 
LED,LCD,CRO,CRT UNIT IV of M&I
LED,LCD,CRO,CRT UNIT IV of M&ILED,LCD,CRO,CRT UNIT IV of M&I
LED,LCD,CRO,CRT UNIT IV of M&I
 
2018 HM-Transmission electron microscope
2018 HM-Transmission electron microscope2018 HM-Transmission electron microscope
2018 HM-Transmission electron microscope
 
DISPLAY DEVICES-CRT
DISPLAY DEVICES-CRTDISPLAY DEVICES-CRT
DISPLAY DEVICES-CRT
 
CRO-CRT.pptx
CRO-CRT.pptxCRO-CRT.pptx
CRO-CRT.pptx
 

More from RevathiJ10

EXTRACELLULAR MATRIX AND ITS COMPONENTS
EXTRACELLULAR MATRIX  AND ITS COMPONENTSEXTRACELLULAR MATRIX  AND ITS COMPONENTS
EXTRACELLULAR MATRIX AND ITS COMPONENTSRevathiJ10
 
Impedance plethysmography Technique.pptx
Impedance plethysmography Technique.pptxImpedance plethysmography Technique.pptx
Impedance plethysmography Technique.pptxRevathiJ10
 
Introduction to Bedside Monitor .pptx
Introduction to  Bedside   Monitor .pptxIntroduction to  Bedside   Monitor .pptx
Introduction to Bedside Monitor .pptxRevathiJ10
 
Patient monitoring system to monitor physiological parameters.pptx
Patient  monitoring system to monitor physiological parameters.pptxPatient  monitoring system to monitor physiological parameters.pptx
Patient monitoring system to monitor physiological parameters.pptxRevathiJ10
 
TYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptx
TYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptxTYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptx
TYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptxRevathiJ10
 
Types of Blood Pressure Measurement Techniques
Types of Blood Pressure Measurement TechniquesTypes of Blood Pressure Measurement Techniques
Types of Blood Pressure Measurement TechniquesRevathiJ10
 
Introduction to science and Engineering.pptx
Introduction to science and Engineering.pptxIntroduction to science and Engineering.pptx
Introduction to science and Engineering.pptxRevathiJ10
 
biology hirarchy.pptx
biology hirarchy.pptxbiology hirarchy.pptx
biology hirarchy.pptxRevathiJ10
 
IMPORTANCE OF BIOLOGY.pptx
IMPORTANCE OF BIOLOGY.pptxIMPORTANCE OF BIOLOGY.pptx
IMPORTANCE OF BIOLOGY.pptxRevathiJ10
 
LUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptx
LUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptxLUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptx
LUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptxRevathiJ10
 

More from RevathiJ10 (10)

EXTRACELLULAR MATRIX AND ITS COMPONENTS
EXTRACELLULAR MATRIX  AND ITS COMPONENTSEXTRACELLULAR MATRIX  AND ITS COMPONENTS
EXTRACELLULAR MATRIX AND ITS COMPONENTS
 
Impedance plethysmography Technique.pptx
Impedance plethysmography Technique.pptxImpedance plethysmography Technique.pptx
Impedance plethysmography Technique.pptx
 
Introduction to Bedside Monitor .pptx
Introduction to  Bedside   Monitor .pptxIntroduction to  Bedside   Monitor .pptx
Introduction to Bedside Monitor .pptx
 
Patient monitoring system to monitor physiological parameters.pptx
Patient  monitoring system to monitor physiological parameters.pptxPatient  monitoring system to monitor physiological parameters.pptx
Patient monitoring system to monitor physiological parameters.pptx
 
TYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptx
TYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptxTYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptx
TYPES OF PRESSURE TRANSDUCERS FOR BIOMEDICAL APPLICATION.pptx
 
Types of Blood Pressure Measurement Techniques
Types of Blood Pressure Measurement TechniquesTypes of Blood Pressure Measurement Techniques
Types of Blood Pressure Measurement Techniques
 
Introduction to science and Engineering.pptx
Introduction to science and Engineering.pptxIntroduction to science and Engineering.pptx
Introduction to science and Engineering.pptx
 
biology hirarchy.pptx
biology hirarchy.pptxbiology hirarchy.pptx
biology hirarchy.pptx
 
IMPORTANCE OF BIOLOGY.pptx
IMPORTANCE OF BIOLOGY.pptxIMPORTANCE OF BIOLOGY.pptx
IMPORTANCE OF BIOLOGY.pptx
 
LUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptx
LUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptxLUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptx
LUBRICATION MECHANISMS OF SYNOVIAL JOINTS.pptx
 

Recently uploaded

Piping and instrumentation diagram p.pdf
Piping and instrumentation diagram p.pdfPiping and instrumentation diagram p.pdf
Piping and instrumentation diagram p.pdfAshrafRagab14
 
Online book store management system project.pdf
Online book store management system project.pdfOnline book store management system project.pdf
Online book store management system project.pdfKamal Acharya
 
Introduction to Heat Exchangers: Principle, Types and Applications
Introduction to Heat Exchangers: Principle, Types and ApplicationsIntroduction to Heat Exchangers: Principle, Types and Applications
Introduction to Heat Exchangers: Principle, Types and ApplicationsKineticEngineeringCo
 
Interfacing Analog to Digital Data Converters ee3404.pdf
Interfacing Analog to Digital Data Converters ee3404.pdfInterfacing Analog to Digital Data Converters ee3404.pdf
Interfacing Analog to Digital Data Converters ee3404.pdfragupathi90
 
litvinenko_Henry_Intrusion_Hong-Kong_2024.pdf
litvinenko_Henry_Intrusion_Hong-Kong_2024.pdflitvinenko_Henry_Intrusion_Hong-Kong_2024.pdf
litvinenko_Henry_Intrusion_Hong-Kong_2024.pdfAlexander Litvinenko
 
Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...
Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...
Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...jiyav969
 
Lesson no16 application of Induction Generator in Wind.ppsx
Lesson no16 application of Induction Generator in Wind.ppsxLesson no16 application of Induction Generator in Wind.ppsx
Lesson no16 application of Induction Generator in Wind.ppsxmichaelprrior
 
"United Nations Park" Site Visit Report.
"United Nations Park" Site  Visit Report."United Nations Park" Site  Visit Report.
"United Nations Park" Site Visit Report.MdManikurRahman
 
Lab Manual Arduino UNO Microcontrollar.docx
Lab Manual Arduino UNO Microcontrollar.docxLab Manual Arduino UNO Microcontrollar.docx
Lab Manual Arduino UNO Microcontrollar.docxRashidFaridChishti
 
Multivibrator and its types defination and usges.pptx
Multivibrator and its types defination and usges.pptxMultivibrator and its types defination and usges.pptx
Multivibrator and its types defination and usges.pptxalijaker017
 
Seismic Hazard Assessment Software in Python by Prof. Dr. Costas Sachpazis
Seismic Hazard Assessment Software in Python by Prof. Dr. Costas SachpazisSeismic Hazard Assessment Software in Python by Prof. Dr. Costas Sachpazis
Seismic Hazard Assessment Software in Python by Prof. Dr. Costas SachpazisDr.Costas Sachpazis
 
Artificial Intelligence Bayesian Reasoning
Artificial Intelligence Bayesian ReasoningArtificial Intelligence Bayesian Reasoning
Artificial Intelligence Bayesian Reasoninghotman30312
 
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024EMMANUELLEFRANCEHELI
 
BORESCOPE INSPECTION for engins CFM56.pdf
BORESCOPE INSPECTION for engins CFM56.pdfBORESCOPE INSPECTION for engins CFM56.pdf
BORESCOPE INSPECTION for engins CFM56.pdfomarzaboub1997
 
The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...
The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...
The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...Roi Lipman
 
Research Methodolgy & Intellectual Property Rights Series 2
Research Methodolgy & Intellectual Property Rights Series 2Research Methodolgy & Intellectual Property Rights Series 2
Research Methodolgy & Intellectual Property Rights Series 2T.D. Shashikala
 
Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...
Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...
Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...ShivamTiwari995432
 
analog-vs-digital-communication (concept of analog and digital).pptx
analog-vs-digital-communication (concept of analog and digital).pptxanalog-vs-digital-communication (concept of analog and digital).pptx
analog-vs-digital-communication (concept of analog and digital).pptxKarpagam Institute of Teechnology
 
Research Methodolgy & Intellectual Property Rights Series 1
Research Methodolgy & Intellectual Property Rights Series 1Research Methodolgy & Intellectual Property Rights Series 1
Research Methodolgy & Intellectual Property Rights Series 1T.D. Shashikala
 
Raashid final report on Embedded Systems
Raashid final report on Embedded SystemsRaashid final report on Embedded Systems
Raashid final report on Embedded SystemsRaashidFaiyazSheikh
 

Recently uploaded (20)

Piping and instrumentation diagram p.pdf
Piping and instrumentation diagram p.pdfPiping and instrumentation diagram p.pdf
Piping and instrumentation diagram p.pdf
 
Online book store management system project.pdf
Online book store management system project.pdfOnline book store management system project.pdf
Online book store management system project.pdf
 
Introduction to Heat Exchangers: Principle, Types and Applications
Introduction to Heat Exchangers: Principle, Types and ApplicationsIntroduction to Heat Exchangers: Principle, Types and Applications
Introduction to Heat Exchangers: Principle, Types and Applications
 
Interfacing Analog to Digital Data Converters ee3404.pdf
Interfacing Analog to Digital Data Converters ee3404.pdfInterfacing Analog to Digital Data Converters ee3404.pdf
Interfacing Analog to Digital Data Converters ee3404.pdf
 
litvinenko_Henry_Intrusion_Hong-Kong_2024.pdf
litvinenko_Henry_Intrusion_Hong-Kong_2024.pdflitvinenko_Henry_Intrusion_Hong-Kong_2024.pdf
litvinenko_Henry_Intrusion_Hong-Kong_2024.pdf
 
Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...
Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...
Vip ℂall Girls Karkardooma Phone No 9999965857 High Profile ℂall Girl Delhi N...
 
Lesson no16 application of Induction Generator in Wind.ppsx
Lesson no16 application of Induction Generator in Wind.ppsxLesson no16 application of Induction Generator in Wind.ppsx
Lesson no16 application of Induction Generator in Wind.ppsx
 
"United Nations Park" Site Visit Report.
"United Nations Park" Site  Visit Report."United Nations Park" Site  Visit Report.
"United Nations Park" Site Visit Report.
 
Lab Manual Arduino UNO Microcontrollar.docx
Lab Manual Arduino UNO Microcontrollar.docxLab Manual Arduino UNO Microcontrollar.docx
Lab Manual Arduino UNO Microcontrollar.docx
 
Multivibrator and its types defination and usges.pptx
Multivibrator and its types defination and usges.pptxMultivibrator and its types defination and usges.pptx
Multivibrator and its types defination and usges.pptx
 
Seismic Hazard Assessment Software in Python by Prof. Dr. Costas Sachpazis
Seismic Hazard Assessment Software in Python by Prof. Dr. Costas SachpazisSeismic Hazard Assessment Software in Python by Prof. Dr. Costas Sachpazis
Seismic Hazard Assessment Software in Python by Prof. Dr. Costas Sachpazis
 
Artificial Intelligence Bayesian Reasoning
Artificial Intelligence Bayesian ReasoningArtificial Intelligence Bayesian Reasoning
Artificial Intelligence Bayesian Reasoning
 
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
NEWLETTER FRANCE HELICES/ SDS SURFACE DRIVES - MAY 2024
 
BORESCOPE INSPECTION for engins CFM56.pdf
BORESCOPE INSPECTION for engins CFM56.pdfBORESCOPE INSPECTION for engins CFM56.pdf
BORESCOPE INSPECTION for engins CFM56.pdf
 
The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...
The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...
The battle for RAG, explore the pros and cons of using KnowledgeGraphs and Ve...
 
Research Methodolgy & Intellectual Property Rights Series 2
Research Methodolgy & Intellectual Property Rights Series 2Research Methodolgy & Intellectual Property Rights Series 2
Research Methodolgy & Intellectual Property Rights Series 2
 
Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...
Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...
Fabrication Of Automatic Star Delta Starter Using Relay And GSM Module By Utk...
 
analog-vs-digital-communication (concept of analog and digital).pptx
analog-vs-digital-communication (concept of analog and digital).pptxanalog-vs-digital-communication (concept of analog and digital).pptx
analog-vs-digital-communication (concept of analog and digital).pptx
 
Research Methodolgy & Intellectual Property Rights Series 1
Research Methodolgy & Intellectual Property Rights Series 1Research Methodolgy & Intellectual Property Rights Series 1
Research Methodolgy & Intellectual Property Rights Series 1
 
Raashid final report on Embedded Systems
Raashid final report on Embedded SystemsRaashid final report on Embedded Systems
Raashid final report on Embedded Systems
 

Introduction to cathode Ray Tube.pptx

  • 1. CATHODE RAY TUBE Dr. J. Revathi Assistant Professor Department of Biomedical Engineering Dr. N.G.P Institute of Technology
  • 2. CATHODE RAY TUBE • The Cathode Ray Tube (CRT) is a vacuum tube containing an electron gun (a source of electrons or electron emitter) and a fluorescent screen used to view images. • It has a mean to accelerate and deflect the electron beam onto the fluorescent screen to create the images. • The image may represent Electrical waveforms in oscilloscope, pictures (television, computer monitor), radar targets. • CRTs have largely superseded by modern technologies such as, LCD, LED, etc, which offer lower manufacturing and distribution cost.
  • 3. PRINCIPLE OF CRT • The Cathode Ray Tube (CRT) is the device that displays images upon a screen using electron beams. • It is a vacuum sealed tube to avoid air resistance. • The electrons are first created at the back of the CRT by an electron gun. • The electrons are shot off the gun at a high velocity and travel through a magnetic field, which steers them in a certain direction
  • 4. • The electrons then pass through a filter (shadow mask) and collide with a phosphor screen, to which they transfer their energy and cause the screen to glow. • Through specific direction of these electron beams, images are created and displayed on the screen.
  • 5. CRT
  • 6. THREE MAIN PARTS • Electron gun • Deflecting plates • Fluorsecent screen
  • 7. ELECTRON GUN The electron gun produces the electron beam that travels through the CRT. The electron gun consists of •cathode •filament •accelerating anode
  • 8. FUNCTION OF CATHODE AND ANODE • The filament is insulated coil of tungsten located inside the cathode • The current is applied to this coil to heat it. • When the cathode is heated, the electrons on the cathode released. • The cathode creates an electron cloud (emits electrons) whose electrons are extracted, accelerated and focused into an electron beam. • The anode serves only to provide the accelerating voltage for the electrons and not as the electron collector.
  • 9. DEFLECTING PLATES • The CRT can use either electrostatic or magnetic deflection. so that the beam of electrons can have its direction altered, allowing the light spot to appear anywhere on the face of the tube. • The cathode-ray-tube deflection system is made up of two pairs of parallel plates known as the vertical and horizontal deflection plates. • The plates are made up of copper or aluminium.
  • 10. ELECTROSTATIC DEFLECTION SYSTEM • Due to this, strong electric field is produced between the plates. • When electron beam enters in this field, it is deflected towards the plate which is positive. • So the path of beam becomes parabolic. • Then the beam comes out of this field in straight line and strikes on the screen at a particular point on the screen.
  • 11. MAGNETIC DEFLECTION SYSTEM • In this system, electron beam is deflected using external magnetic field. • To create alternating magnetic field two pairs of deflection coils, known as yoke, are fitted on the neck of CRT. • The pair of vertical deflection coils is connected to y-input of CRO • The pair of horizontal deflection coils is connected to internal sawtooth wave or external signal at x-input.
  • 12. CRT SCREEN • The CRT screen consists of two main parts: the phosphor screen and the shadow mask. • The phosphor screen turns the electron beam into light, and the shadow mask organizes the beam on the screen. • It contains millions of tiny red, green, and blue phosphor dots that glow when struck by an electron beam that travels across the screen to create a visible image. • The electrons are negative and the screen gives a positive charge so the screen glows. •
  • 13. PHOSPHOR PERSISTENCE • The various phosphors are available depending upon the needs of the measurement or display application. • The brightness, color, and persistence of the illumination depends upon the type of phosphor used on the CRT screen. • Phosphors are available with persistence's ranging from less than one microsecond to several seconds. • For visual observation of brief transient events, a long persistence phosphor may be desirable. • For events which are fast and repetitive, or high frequency, a short-persistence phosphor is generally preferable.
  • 14. ADVANTAGES OF CRT • The cathode rayed tube can easily increase the monitor’s brightness by reflecting the light. • They produce more colours. • The Cathode Ray Tube monitors have lower price rate than the LCD display or Plasma display. • The quality of the image displayed on a Cathode Ray Tube is superior to the LCD and Plasma monitors. • The contrast features of the cathode ray tube monitor are considered highly excellent.
  • 15. DISADVANTAGES OF CRT • The electromagnetic fields emitted by CRT monitors constitute a health hazard to the functioning of living cells. • CRTs emit a small amount of X-ray band radiation which can result in a health hazard. • Constant refreshing of CRT monitors can result in headache. • CRTs operate at very high voltage which can overheat system or result in an implosion