U ninterrupted  P ower  S upply (   UPS   )
UPS   is the Mid-Point Between Utility  &  Critical Load POWER  STATION UTILITY NETWORK UPS CRITICAL   LOAD
Typical Mains Disturbances 3% of failures are related to direct power failures.  The rest is mainly due to fluctuations. TRANSIENT Voltage  Surge  NOISE NOTCHES VOLTAGE DISTORTION  MOMENTARY INTERRUPTION LONG-TERM INTERRUPTION FREQUENCY VARIATION SAG SWELL UNDER VOLTAGE OVER VOLTAGE
UPS Principle 3 Phase Input  Voltage  3  x  415 Vac  Frequency 50 Hz   6-pulse thyristor-controlled Optional :  12pulse thyristor-controlled Standard  DC Voltages    Lead acid Nickel Cadmium  1- or 3-Phase Output  Transistorized or IGBT  PWM - controlled Inverter POWER IN POWER OUT
Rectifier Battery Inverter Bypass SWIN SWMB SWOUT SWBY FROM INPUT DB TO OUTPUT DB UPS  BLOCK START  PROCEDURE *  CHECK SWIN, WSMB, SWBY & SWOUT  SWITCHES ARE OFF. *  PUT SWOUT, SWBY  ON. *  WAIT FOR A MINUTE. *  PUT SWIN ON. *  KEEP SWMB OFF ALWAYS. FOR PUTTING IT ON, REFER MANUAL. STOP  PROCEDURE *  PUTOFF SWOUT. *  PUTOFF SWIN. *  PUTOFF SWBY
Off - line  UPS What is a UPS ? Off-line definition: The UPS is “sleeping” in normal mode  At power failures, power will drop out in  5-20 mSec, until the UPS  “wakes up”. Input voltage Output voltage critical UPS
On-line  UPS What is a UPS ? Input voltage Output voltage On-line definition: The UPS is active in normal mode.  The UPS is constantly regulating the output voltage without any interruption or variations .  UPS
Rectifier Battery Inverter Bypass SWMB FROM INPUT DB UPS  BLOCK 1 Rectifier Battery Inverter SWMB FROM INPUT DB TO OUTPUT DB UPS  BLOCK 2 Static switch Static switch ISOLATED  REDUNDANT  CONFIGURATION
Rectifier Battery Inverter Bypass SWMB FROM INPUT DB UPS  BLOCK 1 Rectifier Battery Inverter SWMB FROM INPUT DB TO  OUTPUT DB UPS  BLOCK 2 Static switch Static switch DISTRIBUTED  PARALLEL  CONFIGURATION Bypass
Rectifier Battery Inverter Bypass SWMB FROM INPUT DB UPS  BLOCK 1 Rectifier Battery Inverter FROM INPUT DB TO OUTPUT DB UPS  BLOCK 2 Static switch CENTRALISED  PARALLEL  CONFIGURATION
 
 
 
 
 
 
 
 
 
 
 
Thanks

Basic Ups

  • 1.
    Technical Seminar by Sandesh Pradhan (Aplab Limited – Thane )
  • 2.
    Head Office- Thane
  • 3.
    ISO 9001 2000certified company India’s largest private Electronic Equipment manufacturer. Started as R&D Laboratory by Mr. P S Deodhar
  • 4.
    U ninterrupted P ower S upply ( UPS )
  • 5.
    UPS is the Mid-Point Between Utility & Critical Load POWER STATION UTILITY NETWORK UPS CRITICAL LOAD
  • 6.
    Typical Mains Disturbances3% of failures are related to direct power failures. The rest is mainly due to fluctuations. TRANSIENT Voltage Surge NOISE NOTCHES VOLTAGE DISTORTION MOMENTARY INTERRUPTION LONG-TERM INTERRUPTION FREQUENCY VARIATION SAG SWELL UNDER VOLTAGE OVER VOLTAGE
  • 7.
    UPS Principle 3Phase Input Voltage 3 x 415 Vac Frequency 50 Hz 6-pulse thyristor-controlled Optional : 12pulse thyristor-controlled Standard DC Voltages Lead acid Nickel Cadmium 1- or 3-Phase Output Transistorized or IGBT PWM - controlled Inverter POWER IN POWER OUT
  • 8.
    Rectifier Battery InverterBypass SWIN SWMB SWOUT SWBY FROM INPUT DB TO OUTPUT DB UPS BLOCK START PROCEDURE * CHECK SWIN, WSMB, SWBY & SWOUT SWITCHES ARE OFF. * PUT SWOUT, SWBY ON. * WAIT FOR A MINUTE. * PUT SWIN ON. * KEEP SWMB OFF ALWAYS. FOR PUTTING IT ON, REFER MANUAL. STOP PROCEDURE * PUTOFF SWOUT. * PUTOFF SWIN. * PUTOFF SWBY
  • 9.
    Off - line UPS What is a UPS ? Off-line definition: The UPS is “sleeping” in normal mode At power failures, power will drop out in 5-20 mSec, until the UPS “wakes up”. Input voltage Output voltage critical UPS
  • 10.
    On-line UPSWhat is a UPS ? Input voltage Output voltage On-line definition: The UPS is active in normal mode. The UPS is constantly regulating the output voltage without any interruption or variations . UPS
  • 11.
    Rectifier Battery InverterBypass SWMB FROM INPUT DB UPS BLOCK 1 Rectifier Battery Inverter SWMB FROM INPUT DB TO OUTPUT DB UPS BLOCK 2 Static switch Static switch ISOLATED REDUNDANT CONFIGURATION
  • 12.
    Rectifier Battery InverterBypass SWMB FROM INPUT DB UPS BLOCK 1 Rectifier Battery Inverter SWMB FROM INPUT DB TO OUTPUT DB UPS BLOCK 2 Static switch Static switch DISTRIBUTED PARALLEL CONFIGURATION Bypass
  • 13.
    Rectifier Battery InverterBypass SWMB FROM INPUT DB UPS BLOCK 1 Rectifier Battery Inverter FROM INPUT DB TO OUTPUT DB UPS BLOCK 2 Static switch CENTRALISED PARALLEL CONFIGURATION
  • 14.
  • 15.
  • 16.
  • 17.
  • 18.
  • 19.
  • 20.
  • 21.
  • 22.
  • 23.
  • 24.
  • 25.