Unit                         1                               2                               3                              4
Power (MWe /MWth)                   460/1380                        784/2381                        784/2381                       784/2381
Type of Reactor                     BWR-3                            BWR-4                          BWR-4                           BWR-4

Status at time of EQ      In service – auto shutdown      In service – auto shutdown      In service – auto shutdown      Outage

Core and fuel integrity   Damaged                         Damaged                         Damaged                         No fuel in the Reactor

RPV & RCS integrity       RPV temperature decreasing      RPV temperature stable          RPV temperature stable          Not applicable due to
                                                                                                                          outage plant status
Containment integrity     No information                  Damage suspected                Damage suspected
                          AC power available - power to   AC power available – power to   AC power available – power to   AC power available – power
AC Power                  instrumentation – Lighting to   instrumentation – Lighting to   instrumentation – Lighting to   to instrumentation – Lighting
                          Central Control Room            Central Control Room            Central Control Room            to Central Control Room

Building                  Severe damage                   Slight damage                   Severe damage                   Severe damage

                          Around half of Fuel is          Around half of Fuel is          Around half of Fuel is
Water level of RPV
                          uncovered                       uncovered                       uncovered

Pressure of RPV           Slowly increasing               Stable                          Stable
                                                                                                                          Not applicable due to
CV Pressure Drywell       Stable                          Stable                          Stable
                                                                                                                          outage plant status
                          Injection of freshwater – via   Injection of freshwater – via   Injection of freshwater – via
Water injection to RPV    mobile electric pump with       mobile electric pump with       mobile electric pump with
                          off-site power                  off-site power                  off-site power
Water injection to CV     No information                  No information                  No information

                                                                                          Freshwater injection via
                          Fresh water injection by        Freshwater injection to the                                     Fresh water injection by
Spent Fuel Pool Status                                                                    Fuel Pool Cooling Line and
                          concrete pump truck             Fuel Pool Cooling Line                                          concrete pump truck
                                                                                          Periodic spraying



05/04/2011 07:00 UTC
Unit                          5                            6
Power                                 784/2381                     1100/3293

Type of Reactor                       BWR-4                         BWR-5

Status at the EQ occurred   Outage                        Outage

Core and Fuel                                                                           Severe condition
RPV & RCS integrity

Containment int.                                                                        Concern
AC Power
                                                                                        No immediate
                                                                                        concern
Building
                            Cold Shutdown                 Cold Shutdown
                            Being maintained using off-   Being maintained using off-
Water level of RPV
                            site electrical power and     site electrical power and
                            existing plant equipment.     existing plant equipment.
Pressure of RPV

Containment Pressure

Water injection to RPV

Water injection to CV

Spent Fuel Pool Status


05/04/2011 07:00 UTC

Table: Summary of reactor unit status at 4-may-0700 utc

  • 1.
    Unit 1 2 3 4 Power (MWe /MWth) 460/1380 784/2381 784/2381 784/2381 Type of Reactor BWR-3 BWR-4 BWR-4 BWR-4 Status at time of EQ In service – auto shutdown In service – auto shutdown In service – auto shutdown Outage Core and fuel integrity Damaged Damaged Damaged No fuel in the Reactor RPV & RCS integrity RPV temperature decreasing RPV temperature stable RPV temperature stable Not applicable due to outage plant status Containment integrity No information Damage suspected Damage suspected AC power available - power to AC power available – power to AC power available – power to AC power available – power AC Power instrumentation – Lighting to instrumentation – Lighting to instrumentation – Lighting to to instrumentation – Lighting Central Control Room Central Control Room Central Control Room to Central Control Room Building Severe damage Slight damage Severe damage Severe damage Around half of Fuel is Around half of Fuel is Around half of Fuel is Water level of RPV uncovered uncovered uncovered Pressure of RPV Slowly increasing Stable Stable Not applicable due to CV Pressure Drywell Stable Stable Stable outage plant status Injection of freshwater – via Injection of freshwater – via Injection of freshwater – via Water injection to RPV mobile electric pump with mobile electric pump with mobile electric pump with off-site power off-site power off-site power Water injection to CV No information No information No information Freshwater injection via Fresh water injection by Freshwater injection to the Fresh water injection by Spent Fuel Pool Status Fuel Pool Cooling Line and concrete pump truck Fuel Pool Cooling Line concrete pump truck Periodic spraying 05/04/2011 07:00 UTC
  • 2.
    Unit 5 6 Power 784/2381 1100/3293 Type of Reactor BWR-4 BWR-5 Status at the EQ occurred Outage Outage Core and Fuel Severe condition RPV & RCS integrity Containment int. Concern AC Power No immediate concern Building Cold Shutdown Cold Shutdown Being maintained using off- Being maintained using off- Water level of RPV site electrical power and site electrical power and existing plant equipment. existing plant equipment. Pressure of RPV Containment Pressure Water injection to RPV Water injection to CV Spent Fuel Pool Status 05/04/2011 07:00 UTC