This training course is a comprehensive course to the technology of shell and tube heat exchangers as these robust type of heat exchangers are the most commonly used in the process and refinery industries, where they provide flexibility and are easy to maintain.
1. Supported by
09th-13thMay2016 | 22nd-26thAugust2016 | 28thNovember-02ndDecember2016
atKualaLumpur,Malaysia
ImproveYourHeatExchangerShell&TubeandCompactTypesPerformancewithLeadingExpert
Petrosync Lecturer
“Large amount of know-how and experience and very practical for the day to day work!”
“Bert is able to make the right connection between the theory and practical issues of heat
exchangers!”
“Much know-how presented in an calm and orderly way with good examples!”
“This is an expert and has many usefull examples!”
“Happy to have had this lecture from expert Bert!”
TEMA&HTRITEMA&HTRI
Testimonials
CaseStudies,
Discussion,Simulation
Learningandmany
Practicalexercises!
Mr. Bert Boxma Chemical Engineer Bsc.
Leading Heat Exchanger Consultant
CEO & President Heat Transfer ABC B.V
Lead course for more than 200 companies
Expert in heat exchanger type selection, special thermal/hydraulic
design,latestenhancedheattransfertechnologiesandgovernmental
subsidy advices
Major Heat Exchanger Projects
FEED phase design of Aircooled system for “state of art” 4th
generation nuclear power station in transient cooling cycle
Design&EngineeringWorldlargestKettletypereboilersfor
LNG Liquifaction Trains.
Heat Exchanger Design & Cost Saving Management
Design & engineering of an advanced helical baffle heat
exchanger design for gas plant warming up cryogenic
subcooled propane liquid with water avoiding freezing
Trouble Shooting experience for large Steam Turbine
Condensers on Fluid Elastic Vibration for different tube
materials
FreeHeatExchanger
SelectionTool!
Over 30 years of experience in heat exchanger
ThefounderandChairmanoftheHTRICommunicationCommitteein
Holland
2. Masterclass Overview
This training course is a comprehensive course to the technology of shell and tube heat exchangers as these robust type
of heat exchangers are the most commonly used in the process and refinery industries, where they provide flexibility
and are easy to maintain.
The course will provide details on the thermal and mechanical design, fabrication, inspection and maintenance in
relation with international standards asTEMA, API and ISO. For this heat exchanger type we focus on the mechanical and
practical aspects.
Many case studies will be presented to show failures, mismatches. The thermal and mechanical design is conducted
using sophisticated computer software and this course is intended to complement thermal design training based on
HTRI software. Attendees will be offered problem case studies in order to reach solutions on their own.
To get a full picture of proven (advanced) heat transfer technologies a basic training module for other types of heat
exchangers is included. Besides aircooled we discuss compact heat exchangers in more detail with all their pro’s and
con’s.
Delegates need to bring Scientific Calculator and Laptop with Microsoft Excel installed and Microsoft as the operating
Specially Designed for
The course is designed for professionals who want to improve the performance of heat exchanger in their
company for shell & tube and compact types
Mechanical Engineer
Design Engineer
Maintenance Engineer
Instrument Engineer
Project Engineer
Process Engineer
Heat Transfer Engineer
Plant Engineer
Operation Engineer
Limited Attendees
The course has limited seats to ensure maximum learning and experience for all delegates.
Certificate of Attendance
You will receive a Certificate of Attendance bearing the signatures of the Trainer upon successful completion of the course. This certificate is proof of
your continuing professional development.
Interactive Training
You will be attending training designed to share both the latest knowledge and practical experience through interactive sessions. This will provide
you with a deeper and more long-term understanding of your current issues.
High Quality Course Materials
Printed course manual will provide you with working materials throughout the course and will be an invaluable source of reference for you and your
colleagues afterward. You can follow course progress on your laptop with soft copies provided.
Petrosync Quality
Masterclass Objectives
For those engineers, this course will provide a broad understanding of the technology and an excellent base for
further learning.
For those responsible for thermal design, TEMA type selection the training is intended to illustrate the interaction
between the thermal and mechanical design, the understanding of which will lead to more reliable design outcomes
For those coming from an operating environment, the course will lead to a greater knowledge of the maintenance,
inspection and repair needs of shell and tube heat exchangers, including information on common causes of failure.
Solutions will be offered using latest “state of art” technologies are used to prevent fouling, tube vibration and
throughput limitations.
3. 1
3
DAY 1
TEMA & HTRI Heat Exchanger Design and Cost Saving Management
09th – 13th May 2016 | 22nd - 26th August 2016 | 28th November - 02nd December 2016
at Kuala Lumpur, Malaysia
SAVE COST • IMPROVE PERFORMANCE • REDUCE RISK
PetroSync understands that in current economic climate, getting an excellent return on your training investment is critical for all our clients. This
excellent training can be conducted exclusively for your organization. The training can be tailored to meet your specific needs at your preferred
location and time. We will meet you anywhere around the globe.
If you like to know more about this excellent program, please contact on +65 6415 4500 or email general@petrosync.com
IN-HOUSE SOLUTIONS
1
& DAY 2
Introduction to Shell & Tube Heat Exchangers (day 1,2)
• General description
• Nomenclature
• Key Components
Standards for Shell & Tube Heat Exchangers
• TEMA, API661, ISO16812
• Computer Simulation Sotftware, HTRI, HTFS, B-Jac
• Text Books
• Maintenance Aspects
Shell & Tube Heat Exchangers
• TEMA Type selection & Design Aspects
• Shell type (Floating Head, Fixed Tube Sheet, U-tube)
• Baffle type (conventional, helical, rod, expanded metal
• Tube type (plain, low-fin, twisted tube and corrugated)
• High Pressure Breech Lock
• Texas Tower, Helitower
• Fabrication Aspects
Case Studies & HTRI Simulations
Thermal Aspects (day 3,4)
• Basic Heat Transfer
• Heating/Cooling (viscous fluids, high pressure gas)
• Condensation (reflux, vacuum)
• Boiling (LNG kettles, thermosyphon, falling film)
• Fouling & Mitigation Technologies
• Tube Insert Technologies
• Design Features
Troubleshooting, Case Studies & HTRI Simulations
Tube Vibration
• Basic Principles
• Fluid elastic vibration
• Acoustic vibration
Troubleshooting, Case Studies & HTRI Simulations
1
DAY 3
1
& DAY 4
1
DAY 5
Introduction to Air Cooled Heat Exchangers (day 5)
• General Description
• Nomenclature
• Key Components (louvers, fans)
• Forced / Induced Draft
• A-frame
Thermal & Mechanical Aspects
• Type selection
• Fouling behavior/mitigation
• Tube Insert Technologies
• Header types
• High Fin tube types
Case Study & HTRI Simulations
Introduction to Compact Heat Exchangers
• Double Pipe / Multi tube
• Plate & Frame
• Spiral Plate
• Brazed Aluminium
• Printed Circuit
• Spiral Coil (LNG)
• Electrical heater
Case Study
Introduction to Special Type
• Open Rack Vaporiser (LNG)
• Submerged Vaporiser (LNG)
• Waterbath Vaporisers
Discussions and Questions
• Total Life Cycle Analysis
• Heat Exchanger Selection Tool
4. Petrosync Lecturer
Mr. Bert Boxma Chemical Engineer Bsc.
08:00–09:00 Registration (Day1)
09:00–11:00 Session I
11:00–11:15 Refreshment & Networking Session I
11:15–13:00 Session II
13:00–14:00
14:00–15:30 Session III
15:30–15:45 Refreshment & Networking Session II
15:45–17:00 Session IV
17:00 End of Day
PROGRAM SCHEDULE
Lunch
Leading Heat Exchanger Consultant
Bert Boxma is the CEO and president of HeatTransfer ABC B.V. with
over 30 years of experience in Heat Exchanger. He is an
international Expert in heat exchanger type selection, special
thermal/hydraulic design, latest enhanced heat transfer technologies
and governmental subsidy advices. Bert already conduct many
training courses and almost 700 employees and more than 200
companies have attended.
CLIENT LIST
• BP
• TOTAL
• Shell Global Solutions
• BASF
• Technip
• Aker Kvaerner
• AKZO
• Arcelor Mittal
• DSM
• Electrabel
• FLUOR
• Jacobs
• NUON Power
• Purac Biochem
• Tijen Twaron
Chairman and member of HTRI’s first Communication Committee
CC-Holland (Chairman 1994 - 1997 ; Member 2004 – Present)
Chairman of NLAHX SenterNovem Working Party (1999 - Present)
Member of ESDU Crude Oil Fouling Working Party (1999 - Present)
Guest Lecturer Technical University Twente & Eindhoven, The
Netherlands
Guest Lecturer HTRI European Seminar October (2004 & 2005)
Member of the working Committee ISO 16812
HTRI’s Representative for The Netherlands (2008 - Present)
ADDITIONAL POSITIONS & CREDENTIALS
Reduced Total Life Cycle Costs Using Helixchanger Heat Exchangers and Enhancement
Technology for the Process Industries.
(Co-Author, Davos, Switzerland July, 2001)
Reduced Total Life Cycle Costs Using Helixchanger Heat Exchangers.
(Co-Author, Hamilton, Canada, October, 2003)
Most frequently used Heat Exchangers from pioneering research to application worldwide
(Co-Author, Prague, Czech Republic, October, 2004)
PUBLICATIONS
5. * For 5 or more delegates, please inquire for more attractive package.
* Important: Please note that registration without payment will incur a SGD 200 administration fee.
1st Delegate Name
Direct Line Number: Email:
Job Title: Department:
Head of Department:
Company:____________________________________________ Industry : __________________________________
Address: _______________________________________________________Postcode: _________________________
Country: ________________________Email: __________________________________________________________
Attention Invoice to: ______________________________________________________________________________
Direct Line Number: ______________________________ Fax: _____________________________________________
PAYMENTMETHODS
DELEGATESDETAILS
Please note:
- Indicate if you have already registered by Phone Fax Email Web
By Credit Card :
Please debit my credit card: Visa MasterCard
Card Number:
Name printed on card: _____________________________________________________________________
Expiry Date:
Security Code:
INVOICEDETAILS
Mrs Ms Dr OthersMr
PROGRAMMECONSULTANT
Name : Cay Aagen
Email : registration@petrosync.com
Phone : +65 6415 4500
Fax : +65 6826 4322
2nd Delegate Name
Direct Line Number: Email:
Job Title: Department:
Head of Department:
Mrs Ms Dr OthersMr
3rd Delegate Name
Direct Line Number: Email:
Job Title: Department:
Head of Department:
Mrs Ms Dr OthersMr
INVESTMENT PACKAGES
AMEX
TERMSANDCONDITIONS
* To enjoy the promotion & discount offer, payment must be made before deadline
* Prices include lunches, refreshments and materials. Promotion & discount cannot be combined with other promotional offers.
- If you have not received an acknowledgement before the training, please call us to confirm your booking.
I agree to PetroSync’s terms & conditions,payment terms and cancellation policy.
Authorized Signature : ____________________________________________________________________________
PAYMENT TERMS : Payment is due in full at the time of registration. Full payment is mandatory for event attendance.
Confirmation
DISCLAIMER
Please note that trainers and topics were confirmed at
the time of publishing; however, PetroSync may
necessitate substitutions, alterations or cancellations of
the trainers or topics. As such, PetroSync reserves the
right to change or cancel any part of its published
programme due to unforeseen circumstances. Any
substitutions or alterations will be updated on our web
page as soon as possible.
DATAPROTECTION
The information you provide will be safeguarded by
PetroSync that may be used to keep you informed of
relevant products and services. As an international
group we may transfer your data on a global basis for
the purpose indicated above. If you do not want us to
share your information with other reputable companies,
please tick this box
CANCELLATIONPOLICY
You may substitute delegates at any time as long as
reasonable advance notice is given to PetroSync. For
any cancellation received in writing not less than
fourteen (14) working days prior to the training course,
you will receive a credit voucher worth total transaction
with less a SGD 200 administration fee and any related
bank or credit card charges.
Delegates who cancel less than fourteen (14) working
days of the training course, or who do not attend the
course, are liable to pay the full course fee and no
refunds will be granted.
In the event that PetroSync cancels or postpones an
event for any reason and that the delegate is unable or
unwilling to attend in on the rescheduled date, you will
receive a credit voucher for 100% of the contract fee
paid. You may use this credit voucher for another
PetroSync to be mutually agreed with PetroSync, which
must occur within a year from the date of postponement.
PetroSync is not responsible for any loss or damage as
a result of the cancellation policy. PetroSync will assume
no liability whatsoever in the event this event is
cancelled, rescheduled or postponed due to any Act of
God, fire, act of government or state, war, civil
commotion, insurrection, embargo, industrial action, or
any other reason beyond management control.
CERTIFICATEOFATTENDANCE
80% attendance is required for PetroSync's Certificate
of Attendance.
DETAILS
Please accept our apologies for mail or email that is
incorrectly addressed.
Please email us at registration@petrosync.com and
inform us of any incorrect details. We will amend them
accordingly.
CHARGES&FEE(s)
- For Payment by Direct TelegraphicTransfer,
client has to bear both local and oversea bank
charges.
- For credit card payment, there is additional
4% credit card processsing fee.
By Direct Transfer : Please quote invoice number(s) on remittance advice
PetroSync Global Pte Ltd Bank details:
All bank charges to be borne by payer. Please ensure that PetroSync Global Pte Ltd receives the full invoiced amount.
Account Name: PetroSync Global Pte Ltd
Bank Name : DBS Bank Ltd
Bank Code : 7171 • Bank Swift Code : DBSSSGSGXXX • Branch code : 288
Account No : • SGD : 288-901898-0 • USD : 0288-002682-01-6
Bank Address : 12 Marina Boulevard, Level 3. Marina Bay Financial Centre Tower 3. Singapore 018982
Early Bird Offer is one month before the event schedule
Group discount is based on standard price
InvestmentPackage Standard Price
09th-13thMay2016
KualaLumpur,Malaysia
Group Discount
(3 or more Delegates)Early Bird Offer
28thNov-02ndDec2016
KualaLumpur,Malaysia
22nd-26thAug2016
KualaLumpur,Malaysia
SGD 4,995 SGD 4,795
Please checklist the package that you are attending!
10% discount for groups of
3 registering from
the same organization
at the same time
SGD 4,995
SGD 4,995
SGD 4,795
SGD 4,795