Performance Paramters of Coal Fired TPS in General for our team.pptx
1. Coal Fired TPS Performance
aspects KPIs
Prepared by
Udhaya kumar BV
Consultant Power Plants
Jindal SAW Pvt Limited
2. Performance Parameters in Coal Fired TPS
w r to design
SH and RH Spray
quantity @ MCR and
at different % of MCR
w r to design
• Main CT Approach/ Range / Cooling
Tower effectiveness / Water Chemistry
to avoid algae growth/ Corrosion
w r to design
Firing : Excess O2%
CO & NOx in ppm; Secondary
Combustion
Flame length, 3Ts , CFCB Bed
Height, Blending of Coal
Domestic & Imported /
Dolochar/ Rice husk/ Char
fines / washery rejects /
Wooden pellets etc
w r to design
Condenser ITD/TTD/LMTD/DP/Air
ingress/ Fouling factors/
Condenser effectiveness &
Efficiency/ Condensate Sub
Cooling
3. Performance Parameters in Coal Fired TPS
w r to design
Fuel Quality,
Quantity , Fineness,
Grindability Index,
w r to design
• Main Steam Temp/ Pressure/
Mass Flow / Pinch Point &
Approach verification & deviation
w r to design
Firing : Excess O2%
CO & NOx in ppm;
Secondary Combustion
Flame length, 3Ts , RH, Dyr
Bulb temperature
w r to design
Primary Air velocity/ Quantity/
Fludisation velocity / Secondary
Air Balanced Flow to the Burners
with 10% difference/ Mills Coal
flow balanced 10%
4. Performance Parameters in Coal Fired TPS
w r to design
ESP Performance Efficiency/
Bottom ash%/ LOI/ Exit FG
losses / Insulation radiation
losses /Moisture in Coal
losses / H2 Losses / APH
efficiency losses / Mill &
Crusher rejects
w r to design
Feed water Heaters
TTD/DCA/Delta
Temp/Delta Pressure
/LMTD
ST Extraction temp/Pressure /
Flow
w r to design & Best
Practices
APC / Emission / Sound
Level / Heat Rate/
Availability / Forced
Outage% /
w r to design & Best O&M Practices
DM Water quality/ Main CW Quality/
ACW Quality/ SWAS limits/ DO2
Limits/ Sulphur & Cold end corrosions
/ NOx /SOX/SPM 2.5 &10/ Chimney
Exit velocity/ Hg / Arsenic/ Lead/
Antimony/ etc
5. Performance Parameters in Coal Fired TPS
w r to design / Best O&M Practices/ Initial feasibility &
Cost sensitivity reports
Cost of Generation /KWh
Cost of Maintenance /KWh
Transmission & Distribution losses ( Transmission Conductor / Xer/ Energy
meters accuracy/ CTs/PTs/ EMVTs/ CVTs)/ Obsolete Inventory losses /
Man Power Attrition Losses / Incident & accident related losses /
Reputation Losses due to Imperfect Policies / Fuel transit & delayed
supply/ penalties losses/ Billing efficiency losses / Trading related losses
/ CSR expenses excess than mandatory / strike & local disturbance /
liasioning expenses exceeding limits/ New statutory fees , regulatory
bodies / surcharges, taxes , duties / Generator efficiency / Lighting
use energy efficient motors/ LED Lamps / Idle transformer losses / over
rated drives/ No VFDs / throttling losses / Leakage losses / Etc
One Unit of energy saved two Units of energy
generated