IMC-III is an intelligent motor controller that provides various motor protection and control functions within a single device. It can start motors using different methods like direct start, Y-Δ start, forward/reverse, and with a reactor. It also monitors for faults like overcurrent, undercurrent, phase loss, locked rotor, and ground faults. The IMC-III allows remote control and monitoring via communication protocols and supports flexible applications through programmable timers, user contacts, and external trip inputs.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document is a product catalogue from Novatek Electro that describes several microcontroller-based protection and automation devices. It includes:
1) Introductions of Novatek Electro and its research, design, and manufacturing capabilities for innovative microcontroller devices.
2) Descriptions of several single phase and three phase voltage monitoring relays that protect loads from voltage fluctuations and provide additional functions.
3) Details of timing relays and a multifunctional programmable timer that can automate processes based on time, light, and voltage conditions.
Started to create milestones, we, Novatek Electro (India) Pvt. Ltd. marked our presence in the year 2009 and operate in the manufacturing/servicing of Microprocessor Based Devices as well as engineers of control since 5 years. Our quality services products have been always appreciated by our clients. Our spontaneous attitude and confident approach in offering an excellent range of Single Phase Voltage Monitoring Relays, Single Phase Voltage Monitoring Relays, Voltage Monitoring & Current Overload Relay, Powerful Voltage Monitoring Relays, Three Phase Voltage Monitoring Relays, Auto Phase Selector Switches, Time Delay Relays, Programmable Astro Timers, Sequential & Combination Timer, Numeric Motor Protection Devices has deepened our roots in the market. We, Novatek Electro (India) Pvt. Ltd. breathe with the aim of fully satisfying our clients with our high-quality products services. We are a unit of highly experienced professionals, all of them contributing at the best of their potentials to offer the highest degree of efficiency and client satisfaction.
Ls catalog thiet bi dien g empr-dmpr_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
The AZBE10A20 is an analog servo drive designed to drive brushless and brushed DC motors. It can provide up to 10A of continuous current and operates on an input voltage range of 40-175VDC. The drive has features such as four quadrant regenerative operation, direct board integration, encoder and tachometer feedback support, and hardware protections against overvoltage, overcurrent, and more.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document describes an analog servo drive called the AZBE60A8. It is designed to drive brushless and brushed DC motors at high switching frequencies. Key specifications include a peak current of 60A, continuous current of 30A, and operating voltage range of 10-80VDC. It has protection against overvoltage, undervoltage, overcurrent and more. It can utilize encoder, hall sensor, or tachometer feedback and supports various motor and operation modes.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document is a product catalogue from Novatek Electro that describes several microcontroller-based protection and automation devices. It includes:
1) Introductions of Novatek Electro and its research, design, and manufacturing capabilities for innovative microcontroller devices.
2) Descriptions of several single phase and three phase voltage monitoring relays that protect loads from voltage fluctuations and provide additional functions.
3) Details of timing relays and a multifunctional programmable timer that can automate processes based on time, light, and voltage conditions.
Started to create milestones, we, Novatek Electro (India) Pvt. Ltd. marked our presence in the year 2009 and operate in the manufacturing/servicing of Microprocessor Based Devices as well as engineers of control since 5 years. Our quality services products have been always appreciated by our clients. Our spontaneous attitude and confident approach in offering an excellent range of Single Phase Voltage Monitoring Relays, Single Phase Voltage Monitoring Relays, Voltage Monitoring & Current Overload Relay, Powerful Voltage Monitoring Relays, Three Phase Voltage Monitoring Relays, Auto Phase Selector Switches, Time Delay Relays, Programmable Astro Timers, Sequential & Combination Timer, Numeric Motor Protection Devices has deepened our roots in the market. We, Novatek Electro (India) Pvt. Ltd. breathe with the aim of fully satisfying our clients with our high-quality products services. We are a unit of highly experienced professionals, all of them contributing at the best of their potentials to offer the highest degree of efficiency and client satisfaction.
Ls catalog thiet bi dien g empr-dmpr_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
The AZBE10A20 is an analog servo drive designed to drive brushless and brushed DC motors. It can provide up to 10A of continuous current and operates on an input voltage range of 40-175VDC. The drive has features such as four quadrant regenerative operation, direct board integration, encoder and tachometer feedback support, and hardware protections against overvoltage, overcurrent, and more.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document describes an analog servo drive called the AZBE60A8. It is designed to drive brushless and brushed DC motors at high switching frequencies. Key specifications include a peak current of 60A, continuous current of 30A, and operating voltage range of 10-80VDC. It has protection against overvoltage, undervoltage, overcurrent and more. It can utilize encoder, hall sensor, or tachometer feedback and supports various motor and operation modes.
Sentinel Dual is the best solution for powering mission critical applications and electro-medical devices requiring maximum power reliability.Sentinel Dual can be installed on the floor or in rack cabinets for networking applications.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Tense Electronics is a Turkish company that produces industrial automation products. It has been operating since 2006 and exports to over 40 countries from its production facility in Istanbul. The company aims to provide high quality, customized solutions to customers using new technologies. Tense Electronics holds certifications like CE, UKRSEPRO, and GOST-R and produces products like power factor controllers, protection relays, and monitoring equipment.
Explore the compact inverter WJ200 series built for excellent performance and user-friendliness.
To learn more about Hitachi Inverters, visit: https://www.hitachi-iesa.com/ac-drives-inverters
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document provides specifications for the AZBE25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies up to 25A continuous current. It has features like four quadrant regenerative operation, direct board integration, encoder and tachometer feedback support, and hardware protections. The drive requires only a single DC power supply and complies with safety and emissions standards.
The PML-1000 is an AC line powered panel meter for measuring LVDT/RVDT sensors. It features a large 5-digit LED display, 0-10VDC and 4-20mA outputs, optional RS422/485 communications, and easy calibration. The meter provides functions like minimum, maximum, average readings and is compatible with various Measurement Specialties sensors.
Weg automation-drives-and-controls-usa804-brochure-englishDaniel García
This document provides information on automation products from WEG, including contactors and overload relays, timers and monitoring relays, pushbuttons and pilot lights, soft starters, variable frequency drives, motor protective circuit breakers, terminals, air circuit breakers, capacitors for power factor correction, and automation systems. WEG offers a comprehensive portfolio of low and medium voltage automation equipment for industrial applications.
Hydraulic Electro Hydraulic Training SetFaruk Kartal
Hydraulic and electrohydraulic training set using for hydraulic training. It contains 12 different unit that replaceable in below.
1. Training panel
2. Drawer unit
3. Input module
4. Buttons and signal lamps module
5. Relays module
6. Time relay module
7. Counter module
8. Motor module (DC motor, stepping motor, encoder)
9. PLC module (SIEMENS S7 1200)
10. Proportional directional control valve module
11. Proportional pressure control valve module
The document provides specifications for the AZBE20A8 analog servo drive. Some key details:
- It is designed to drive brushless and brushed DC motors at high switching frequency and can integrate directly into a PCB.
- It provides overcurrent, overvoltage, and other hardware protections. Feedback can be provided by encoders, hall sensors, or tachometers.
- It has a peak current of 20A, continuous current of 12A, and operates from a 10-80VDC power supply. Modes include current control, duty cycle, and velocity control.
The document describes an analog servo drive that can drive brush DC motors. It provides peak currents of 30A and continuous currents of 15A. It operates from a 30-125VAC supply and has adjustable current limits, input gain, and offset. It supports feedback from tachometers and position sensors and can operate in different modes like current and velocity control. It has protections against overcurrent, overvoltage, and short circuits.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document provides specifications for the AZBH25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies. It has a peak current of 25A, continuous current of 12.5A, and operates on a DC supply voltage of 40-175VDC. The drive provides various protection features and supports different feedback and operation modes.
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.comBeeteco
Catalog Biến tần Frenic ACE Mini
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
This document provides information on Fuji Electric's new FRENIC-Mini compact inverter. Key details include:
- The FRENIC-Mini offers high performance control of motors and equipment in a compact package with simple operation and global compatibility.
- It has rich functionality, compact design, easy operation/maintenance, and compatibility with existing Fuji products and networks.
- Specifications include voltage and frequency ranges, overload capabilities, enclosure type, cooling method, and applicable motor ratings from 0.1 to 3.7 kW.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...Dien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Catalog LS, Catalog,
Catalog Thiết Bị Điện LS, Catalog Thiết Bị Điện,
http://dienhathe.com,
Chi tiết các sản phẩm khác của LS tại https://dienhathe.com
Xem thêm các Catalog khác của LS tại https://dienhathe.info
Để nhận báo giá sản phẩm LS vui lòng gọi: 0907.764.966
The AZBE40A8 is a PWM servo drive designed to drive brushless and brushed DC motors. It can provide a peak current of 40A and continuous current of 20A, with a supply voltage range of 10-80VDC. The drive is fully protected against over-voltage, under-voltage, over-current and other faults. It supports various feedback and operation modes including encoder velocity control.
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910Dien Ha The
Catalog LS, Catalog,
Catalog Thiết Bị Điện LS, Catalog Thiết Bị Điện,
Catalog Biến Tần LS, Catalog Biến Tần,
Catalog Inverter LS, Catalog Inveter,
http://dienhathe.com,
Chi tiết các sản phẩm khác của LS tại https://dienhathe.com
Xem thêm các Catalog khác của LS tại https://dienhathe.info
Để nhận báo giá sản phẩm LS vui lòng gọi: 0907.764.966
This servo drive is designed to drive brushless DC motors at high power levels. It can operate in various modes including current, velocity, and duty cycle modes. It has protections against overheating, overcurrent and other faults. It is compliant with various safety standards and has adjustable parameters, feedback options and I/O for control and monitoring.
Sentinel Dual is the best solution for powering mission critical applications and electro-medical devices requiring maximum power reliability.Sentinel Dual can be installed on the floor or in rack cabinets for networking applications.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Tense Electronics is a Turkish company that produces industrial automation products. It has been operating since 2006 and exports to over 40 countries from its production facility in Istanbul. The company aims to provide high quality, customized solutions to customers using new technologies. Tense Electronics holds certifications like CE, UKRSEPRO, and GOST-R and produces products like power factor controllers, protection relays, and monitoring equipment.
Explore the compact inverter WJ200 series built for excellent performance and user-friendliness.
To learn more about Hitachi Inverters, visit: https://www.hitachi-iesa.com/ac-drives-inverters
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document provides specifications for the AZBE25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies up to 25A continuous current. It has features like four quadrant regenerative operation, direct board integration, encoder and tachometer feedback support, and hardware protections. The drive requires only a single DC power supply and complies with safety and emissions standards.
The PML-1000 is an AC line powered panel meter for measuring LVDT/RVDT sensors. It features a large 5-digit LED display, 0-10VDC and 4-20mA outputs, optional RS422/485 communications, and easy calibration. The meter provides functions like minimum, maximum, average readings and is compatible with various Measurement Specialties sensors.
Weg automation-drives-and-controls-usa804-brochure-englishDaniel García
This document provides information on automation products from WEG, including contactors and overload relays, timers and monitoring relays, pushbuttons and pilot lights, soft starters, variable frequency drives, motor protective circuit breakers, terminals, air circuit breakers, capacitors for power factor correction, and automation systems. WEG offers a comprehensive portfolio of low and medium voltage automation equipment for industrial applications.
Hydraulic Electro Hydraulic Training SetFaruk Kartal
Hydraulic and electrohydraulic training set using for hydraulic training. It contains 12 different unit that replaceable in below.
1. Training panel
2. Drawer unit
3. Input module
4. Buttons and signal lamps module
5. Relays module
6. Time relay module
7. Counter module
8. Motor module (DC motor, stepping motor, encoder)
9. PLC module (SIEMENS S7 1200)
10. Proportional directional control valve module
11. Proportional pressure control valve module
The document provides specifications for the AZBE20A8 analog servo drive. Some key details:
- It is designed to drive brushless and brushed DC motors at high switching frequency and can integrate directly into a PCB.
- It provides overcurrent, overvoltage, and other hardware protections. Feedback can be provided by encoders, hall sensors, or tachometers.
- It has a peak current of 20A, continuous current of 12A, and operates from a 10-80VDC power supply. Modes include current control, duty cycle, and velocity control.
The document describes an analog servo drive that can drive brush DC motors. It provides peak currents of 30A and continuous currents of 15A. It operates from a 30-125VAC supply and has adjustable current limits, input gain, and offset. It supports feedback from tachometers and position sensors and can operate in different modes like current and velocity control. It has protections against overcurrent, overvoltage, and short circuits.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
The document provides specifications for the AZBH25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies. It has a peak current of 25A, continuous current of 12.5A, and operates on a DC supply voltage of 40-175VDC. The drive provides various protection features and supports different feedback and operation modes.
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.comBeeteco
Catalog Biến tần Frenic ACE Mini
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
This document provides information on Fuji Electric's new FRENIC-Mini compact inverter. Key details include:
- The FRENIC-Mini offers high performance control of motors and equipment in a compact package with simple operation and global compatibility.
- It has rich functionality, compact design, easy operation/maintenance, and compatibility with existing Fuji products and networks.
- Specifications include voltage and frequency ranges, overload capabilities, enclosure type, cooling method, and applicable motor ratings from 0.1 to 3.7 kW.
Công ty TNHH Hạo Phương là đối tác phân phối các thiết bị điện công nghiệp của hãng Fuji Electric (Nhật Bản): MCCB, MCB, Contactor, Servo Motor, biến tần, màn hình cảm ứng, PLC...
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...Dien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Catalog LS, Catalog,
Catalog Thiết Bị Điện LS, Catalog Thiết Bị Điện,
http://dienhathe.com,
Chi tiết các sản phẩm khác của LS tại https://dienhathe.com
Xem thêm các Catalog khác của LS tại https://dienhathe.info
Để nhận báo giá sản phẩm LS vui lòng gọi: 0907.764.966
The AZBE40A8 is a PWM servo drive designed to drive brushless and brushed DC motors. It can provide a peak current of 40A and continuous current of 20A, with a supply voltage range of 10-80VDC. The drive is fully protected against over-voltage, under-voltage, over-current and other faults. It supports various feedback and operation modes including encoder velocity control.
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910Dien Ha The
Catalog LS, Catalog,
Catalog Thiết Bị Điện LS, Catalog Thiết Bị Điện,
Catalog Biến Tần LS, Catalog Biến Tần,
Catalog Inverter LS, Catalog Inveter,
http://dienhathe.com,
Chi tiết các sản phẩm khác của LS tại https://dienhathe.com
Xem thêm các Catalog khác của LS tại https://dienhathe.info
Để nhận báo giá sản phẩm LS vui lòng gọi: 0907.764.966
This servo drive is designed to drive brushless DC motors at high power levels. It can operate in various modes including current, velocity, and duty cycle modes. It has protections against overheating, overcurrent and other faults. It is compliant with various safety standards and has adjustable parameters, feedback options and I/O for control and monitoring.
This document describes a pulse counter circuit using an AT89C4051 microcontroller. It includes a circuit schematic and descriptions of the major components used, including the AT89C4051 microcontroller, MAX232 RS-232 driver, 7805 voltage regulator, LCD display, 11.0592MHz crystal, and other passive components. The circuit uses the microcontroller to count input pulses and display the count on the LCD. Hardware and functionality of the components are explained in detail.
Subtech:Automatic Changeover,ACCL, AMF Panel, Motor Starter etc.latesh sharma
Since 1995, we have established ourselves as a manufacturer and exporter of generator control devices, Water tank automation product and support components like AMF Panels, Automatic Changeovers up to 1000 kva, Timers, Automatic Motor Starter, Water Pump Controller, Power management system with Dual Source Prepaid Energy Meter & others electronic/electrical devices for automation of power which are better known for their compatibility, functionality and life-long services. We put great stress on quality of products & customer's satisfaction.
This document provides information about the Analog Servo Drive BE25A20AC:
1) It is a PWM servo drive designed to drive brushless DC motors at high switching frequencies up to 25A of peak current and 12.5A of continuous current.
2) It has fully adjustable current and velocity control loops as well as protective features against overloads and faults.
3) The drive can operate in different modes such as current control, duty cycle control and encoder velocity control using potentiometers and DIP switches for configuration.
This document describes a project to control the speed of an AC induction motor using a microcontroller and TRIAC. A microcontroller sends commands to a cyclo-converter which controls the frequency of the AC power supplied to the motor, thereby controlling its speed. The microcontroller activates an optocoupler connected to a TRIAC, which allows AC power to flow to the motor and rotate it when triggered. Keypad inputs are used to control the microcontroller and select different motor speeds.
The document describes an analog servo drive model B100A8. It can provide up to 100A of peak current and 50A of continuous current from a 20-80VDC power supply. It is designed to drive brushless DC motors and features adjustable current limits, gain, and offset settings. It supports Hall sensor, encoder, and tachometer feedback and can operate in various modes including current and velocity control.
This document provides technical specifications for ABB's range of automatic transfer switches (ATS). It describes the key features and functionality of the ATS including their operating voltage range, current ratings, switching times, and control unit options. The ATS can automatically switch the power supply source to prevent outages and come equipped with monitoring and configuration capabilities for safe and reliable operation.
The AZBH60A8 analog servo drive is designed to drive brushless and brushed DC motors at high switching frequencies. It can provide up to 60A of peak current and 30A of continuous current from a 10-80VDC power supply. The drive has protections against overvoltage, undervoltage, overcurrent, overheating and other faults. It interfaces with digital controllers using analog +/-10V commands and supports Hall sensor or tachometer feedback.
The document describes an analog servo drive called the BE25A20I. It has the following key specifications:
- It can provide up to 25A of peak current and 12.5A of continuous current.
- It is designed to drive brushless DC motors and can operate in various modes like current, duty cycle, and velocity modes.
- It has protections against overheating, overvoltage, undervoltage, and short circuits.
- It can interface with encoders, Hall sensors, or tachometers for motor feedback and supports motors with three phases.
This servo drive amplifier can provide up to 250A of peak current and 150A of continuous current. It is designed to drive brushless DC motors and interface with digital controllers. It has protection against overheating, overcurrent and other faults. Operating modes include current control, velocity control using encoders or Hall sensors, and it can drive brushed or brushless motors.
The S60A8 analog servo drive is designed to drive 3-phase brushless motors with sinusoidal current. It requires 2 sinusoidal command signals 120 degrees out of phase to control motor position and torque. The drive interfaces with digital controllers, has overvoltage, overcurrent, and overheating protections, and operates from a single DC power supply. It provides optical isolation between high and low power signals.
Zhuhai Sinopak Electric Ltd produces motor drives and power quality equipment including medium and low voltage variable frequency drives, soft starters, static synchronous compensators, and active power filters. The company aims to improve production efficiency and energy savings for customers across Southeast Asia, Eastern Europe, the Middle East, and Africa.
Zhuhai Sinopak Electric Ltd produces motor drives and power quality equipment including medium and low voltage variable frequency drives, soft starters, static synchronous compensators, and active power filters. The company aims to improve production efficiency and energy savings for customers across Southeast Asia, Eastern Europe, the Middle East, and Africa.
Zhuhai Sinopak Electric Ltd produces motor drives and power quality equipment including medium and low voltage variable frequency drives, soft starters, static synchronous compensators, and active power filters. The company aims to improve production efficiency and energy savings for customers across Southeast Asia, Eastern Europe, the Middle East, and Africa.
The document describes the Analog Servo Drive AZBH10A20, which is designed to drive brushless and brushed DC motors. It can provide up to 10A of peak current and 6A of continuous current, operating from 40-175VDC. The drive has features like four quadrant regenerative operation, direct PCB integration, fault monitoring, and supports Hall sensors or tachometers for feedback and various modes of operation.
The document describes the Analog Servo Drive S100A20. It is designed to drive 3-phase brushless motors with sine wave current control. It interfaces directly with digital controllers and requires only a single unregulated DC power supply. It provides fully protected operation and indicators for status.
The document describes an analog servo drive that:
- Can provide up to 30A of peak current and 15A of continuous current from a 45-265VAC power supply.
- Includes protections against overvoltage, overcurrent, overheating and other faults.
- Can be controlled via analog voltage commands and supports Hall sensors, encoders and tachometers for feedback.
- Has adjustable current limits, commutation phasing and other parameters via onboard potentiometers.
Similar to Ls catalog thiet bi tu dong imc iii-e (20)
This document provides a quick start guide for the FED-C Series AC drive. It includes information on safety, wiring, the operating panel, quick setup, standard parameters, troubleshooting, and revision history. The guide contains basic instructions to get started with installation and configuration of the AC drive.
Fed e-quick-start-manual-bientanfuji-dienhathe.comDien Ha The
This quick start guide provides instructions for setting up and operating an inverter. It begins with an overview of product information, including nameplate details and specifications. It then covers wiring, including diagrams for 3-phase and single-phase power supply types. Terminal functions are described for the main circuit and control circuit. The guide presents a timing diagram for the control logic and acceleration/deceleration profiles. It concludes with a step-by-step setup process, including getting familiar with the keypad, setting motor parameters, checking rotation direction, and setting function codes for features like the startup frequency and DC injection braking.
Bảng giá LS 2019 - Bảng giá mới sẽ áp dụng từ ngày 20.0.2019
Để cập nhật các bảng giá mới lĩnh vực thiết bị điện Công
Nghiệp.Quý khách vui lòng vào link bên dưới
https://www.dienhathe.com/download/bang-gia-dien-cong-nghiep/?filter_nam=2019&filter_tai-lieu=bang-gia
Mitsubishi graphic operation terminal got2000 series parts library bookDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi inverter fr-a700-instruction-manualbasic-160425031653Dien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi graphic operation terminal got2000 series gt2103 new product releaseDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi graphic operation terminal got2000 series got mobile function quic...Dien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi graphic operation terminal got2000 series drive control interactiv...Dien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi low voltage ws-v series mccb and elcbDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi graphic operation terminal got2000 series (concise)Dien Ha The
- Monitor the GOT screen from a remote location.
- Switch screens and operate touch switches.
Control:
- Monitor and operate the GOT from a remote location.
- Switch screens, operate touch switches, change settings, and more.
Number of
simultaneous
connections
1 client
Multiple clients✽1
Screen
switching
Not possible
Possible✽2
Client OS
Windows, Linux, macOS, Android, iOS
Windows, Linux, macOS, Android, iOS
Client software
- Web browser
- Viewer software
- Web browser
- VNC client software✽3
Mitsubishi low voltage ws-v series comparison of previous and new modelsDien Ha The
1. The document compares previous and new models of molded-case circuit breakers and earth-leakage circuit breakers.
2. It outlines differences in dimensions, performance, and specifications between previous W & WS series models and new WS-V series models. Key changes include changes in tripping methods, operating characteristics, dimensions, rated currents, and breaking capacities.
3. Replacement models are identified for previous models, along with any drilling dimension or front plate cutout changes between models. Some models were added or had specifications adjusted.
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi low voltage miniature circuit breakers din seriesDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi low voltage mccb and elcb(ws-v series) y0720-version 1-mitsuDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi inverter freqrol-f700 pj seriesDien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Mitsubishi inverter catalog-mitsubishi-inverter-option-160426021125Dien Ha The
Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Embedded machine learning-based road conditions and driving behavior monitoringIJECEIAES
Car accident rates have increased in recent years, resulting in losses in human lives, properties, and other financial costs. An embedded machine learning-based system is developed to address this critical issue. The system can monitor road conditions, detect driving patterns, and identify aggressive driving behaviors. The system is based on neural networks trained on a comprehensive dataset of driving events, driving styles, and road conditions. The system effectively detects potential risks and helps mitigate the frequency and impact of accidents. The primary goal is to ensure the safety of drivers and vehicles. Collecting data involved gathering information on three key road events: normal street and normal drive, speed bumps, circular yellow speed bumps, and three aggressive driving actions: sudden start, sudden stop, and sudden entry. The gathered data is processed and analyzed using a machine learning system designed for limited power and memory devices. The developed system resulted in 91.9% accuracy, 93.6% precision, and 92% recall. The achieved inference time on an Arduino Nano 33 BLE Sense with a 32-bit CPU running at 64 MHz is 34 ms and requires 2.6 kB peak RAM and 139.9 kB program flash memory, making it suitable for resource-constrained embedded systems.
CHINA’S GEO-ECONOMIC OUTREACH IN CENTRAL ASIAN COUNTRIES AND FUTURE PROSPECTjpsjournal1
The rivalry between prominent international actors for dominance over Central Asia's hydrocarbon
reserves and the ancient silk trade route, along with China's diplomatic endeavours in the area, has been
referred to as the "New Great Game." This research centres on the power struggle, considering
geopolitical, geostrategic, and geoeconomic variables. Topics including trade, political hegemony, oil
politics, and conventional and nontraditional security are all explored and explained by the researcher.
Using Mackinder's Heartland, Spykman Rimland, and Hegemonic Stability theories, examines China's role
in Central Asia. This study adheres to the empirical epistemological method and has taken care of
objectivity. This study analyze primary and secondary research documents critically to elaborate role of
china’s geo economic outreach in central Asian countries and its future prospect. China is thriving in trade,
pipeline politics, and winning states, according to this study, thanks to important instruments like the
Shanghai Cooperation Organisation and the Belt and Road Economic Initiative. According to this study,
China is seeing significant success in commerce, pipeline politics, and gaining influence on other
governments. This success may be attributed to the effective utilisation of key tools such as the Shanghai
Cooperation Organisation and the Belt and Road Economic Initiative.
Introduction- e - waste – definition - sources of e-waste– hazardous substances in e-waste - effects of e-waste on environment and human health- need for e-waste management– e-waste handling rules - waste minimization techniques for managing e-waste – recycling of e-waste - disposal treatment methods of e- waste – mechanism of extraction of precious metal from leaching solution-global Scenario of E-waste – E-waste in India- case studies.
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsVictor Morales
K8sGPT is a tool that analyzes and diagnoses Kubernetes clusters. This presentation was used to share the requirements and dependencies to deploy K8sGPT in a local environment.
DEEP LEARNING FOR SMART GRID INTRUSION DETECTION: A HYBRID CNN-LSTM-BASED MODELgerogepatton
As digital technology becomes more deeply embedded in power systems, protecting the communication
networks of Smart Grids (SG) has emerged as a critical concern. Distributed Network Protocol 3 (DNP3)
represents a multi-tiered application layer protocol extensively utilized in Supervisory Control and Data
Acquisition (SCADA)-based smart grids to facilitate real-time data gathering and control functionalities.
Robust Intrusion Detection Systems (IDS) are necessary for early threat detection and mitigation because
of the interconnection of these networks, which makes them vulnerable to a variety of cyberattacks. To
solve this issue, this paper develops a hybrid Deep Learning (DL) model specifically designed for intrusion
detection in smart grids. The proposed approach is a combination of the Convolutional Neural Network
(CNN) and the Long-Short-Term Memory algorithms (LSTM). We employed a recent intrusion detection
dataset (DNP3), which focuses on unauthorized commands and Denial of Service (DoS) cyberattacks, to
train and test our model. The results of our experiments show that our CNN-LSTM method is much better
at finding smart grid intrusions than other deep learning algorithms used for classification. In addition,
our proposed approach improves accuracy, precision, recall, and F1 score, achieving a high detection
accuracy rate of 99.50%.
Manufacturing Process of molasses based distillery ppt.pptx
Ls catalog thiet bi tu dong imc iii-e
1. 2008
Leader in Electrics & Automation
Electric Equipment
General Catalog
www.dienhathe.xyz
www.dienhathe.vn
2. IMC-III
Intelligent Motor Controller
IMC-III is for low voltage motor under 1000V,
and is integrated motor protection relay,
Indication lamp, Current transformer(CT).
IMC-III is intelligent motor controller which has
high micro-Processor Technique.
www.dienhathe.xyz
www.dienhathe.vn
3. Contents Main characteristic O-6
Ratings and function O-8
Main function description O-10
Operation and setting O-12
Wiring method O-16
System configuration O-20
Accessories O-22
Dimension & Ordering O-23
IMC-III includes Direct, Y-△, Forward/Reverse, Reactor,
Inverter, S/V valve start, solution for complicated water
treatment Sequence.
IMC-III also has various motor protection function, and is
possible to communicate with PLC, Water level for auto
operating, remote control and monitoring by RS-485,
4~20mA(only monitoring).
O
www.dienhathe.xyz
www.dienhathe.vn
4. Various motor start application
within one model.
IMC-III includes Direct, Y-�, Forward/Reverse, Reactor, Inverter,
S/V valve start, solution for complicated water treatment Sequence.
Digital motor
protection control unitIMC-III
Direct start
Overcurrent
Under current
Phase
lossPhase
reverse
Unbalance
Stall/Locked
rotor
Earth
fault
Y-△△ start
For/Rev
start
Reactor start
Inverter start
S/V valve start
Various protection function
Safely protection for over current, Under current,
Phase loss, Unbalance, (Stall, Lock)
Earth fault, Alarm function.
O-4
www.dienhathe.xyz
www.dienhathe.vn
5. IMC-III
O
Various remote control
and monitoring
It is possible to operate at MCC and LOP
by just simple sequence, also can be
automatic operation up to water level by
remote control and monitoring with
PLC/DCS.
Emergency
Stop
PLC
WaterLevel
MCC
Localoperating
panel
SCADA
O-5
www.dienhathe.xyz
www.dienhathe.vn
6. Internal
Front
�2 times(0.25~3A)
�A group → 5.ctr 0.5 setting
�4 times(0.125~1.5A)
�A group → 5.ctr 0.25 setting
�External CT
Wide current setting range : 0.125A~1000A within 1 model
It can be changed from 0.5~6A to 5~60A by slide S/W, the current can be changed to 0.125A
up to MCT number of the time of penetrating current line.
EMPR or TOR
Button & Lamp
TIMER
Aux Relay
A-Meter
CT
* External CT : Note p22 (option)
* MCT : Molded current transformer(Enclosing with product)
●● Minimizing wiring
work
●● Reduce labor cost
●● Compact size panel
●● Easy maintenance
●● Good design
●● Various function
O-6
Intelligent Motor Controller
Main characteristic
Easy and convenience installation
It can be checked fault analysis and operated motor by inserting the main unit into panel. It°Øs
possible to set current/operating time/various function easily by simple button. And it can be also
composed of compact MCC, minimized wiring work, so user can reduce labor cost.www.dienhathe.xyz
www.dienhathe.vn
7. IMC-III
O
O-7
The moment stopping of power supply compensation and Restart
■■ The moment stopping of power supply compensation
- Line current reduces under 65% of rated voltage.
- When the moment stopping of power supply within 10S,
IMC-III makes it restart same as before condition.
■■ Restart delayed time(0~300S)
- When the line voltage recovers over 75% rated voltage,
it can be restarted.
- when it restarted, IMC-III makes it sequence restart 0~300s for
prohibition overload.
- Indication of Restart delayed time countdown.
■■ Operating condition and maintain operation mode
- It can be maintained before the moment stopping power
supply condition(Local, MCC, Auto, W/L, Remote)
Self-supervision and contactor failure function
IMC-III can be checked self-supervision like a memory fault. When the motor starts/stops,
that indicates Error.No and turn on Sys.Fail LED by supervising Input/output condition.
Total operation time setting and storage
It can be stored motor operation time up to 10 years. Continuous operation time can be stored and setting.
Communication function
It’s possible to communicate with other system and organize various communication Network by
MODBUS/RS-485. And it’s also possible to communicate with system by Analog current signal(4~20mA).
So that makes it possible to interchange by using TD(Transducer).
Fault analysis and Recording
It can be indicated fault cause and fault current value by 7-segment and LED.
At the moment of instantaneous stopping of power supply, it can solve the problem. Because of the fault storage.
Digital ampere-meter
It can be monitored indication of R, S, T current, and load ratings(%) by Bar LED.
R-phase S-phase T-phase Max current
Bar LED
Indication of load ratings
Ex) Incase of restarting delayed time 30S
�It can be changed operation mode (ON, OFF) and
count time during countdown
�Changed operation mode can be applied after
finishing count.
�When the short stopping power supply generates
under 100ms, IMC-III dose not detect, so the motor
will maintain normal condition
Information
When the user contact mode is normal mode, even if indicating“OrH Alarm, motor operates in normal condition
Information
www.dienhathe.xyz
www.dienhathe.vn
8. O-8
Intelligent Motor Controller
Ratings and function
Model IMC-III
Operating time Characteristic Inv/Def time
Current range(A) 0.125~60A(Within 1 model)
Time setting (s) Inverse time 1~60sec/1sec(Class)
Definite time D-Time * 1~200sec/1sec
O-Time * 1~60sec/1sec
Auto re-closing time 1~20min/1min, OFF
Control power Voltage AC 110V or AC 220V(±15%)
Frequency 50/60Hz
Power consumption Under 6W
Output contact Capacity 5A/250VAC impedance load
(9EA) Composition Operating contact 3a Forward/Reverse, Y-�, Reactor, Inverter start
Condition contact 3a Local, Auto, W/L condition indication
Timer contact 2a ON delay, OFF delay
Trip contact 1a Fault output contact
Input contact Operating input 5a Local, Auto, Water, Level, Flow, switch operating inout
(9EA) MC condition input 1a Sequence condition monitoring(LED)
External trip 2a Emergency stop, Sequence
ZCT Ratings 200mA/0.1mA(ZCT)
Specification ∅25, ∅40, ∅80
Indication 7-Segment 3-Phase current, Trip cause, Settings
LED Operating condition, Trip, System fail settings
Self-Diagnostic System fail LED and err indication
Communication(Option) Modbus/RS-485 or 4~20mA
Installation Inside the panel
Separate cable MCT cable 2m base(4m cable option)
Insulation voltage AC 2kV(1.5kV) / 1 min
Impulse voltage Over AC 5kV(3kV), 1.2x50μs
Insulation resistance Over DC500V 10MΪ
Power frequency magnetic field 100A/m, 50Hz
Burst disturbance Common 2.5kV
Differential 1.0kV
Fast transients disturbance Input 2kV, Other Input 1kV
Electrostatic discharge Air 8kV, Contact 6kV
RFI 30cm near electric wave by
5W transceiver(230MHz)
EMI AC power : 0.15~0.50MHz, Standard : 79dB, Average : 66dB
0.50~30MHz, Standard : 73dB Average : 60dB
Operating temperature -10 ~ 55℃
Storage temperature -20 ~ 70℃
Relative humidity 93% @40℃ for 56days
Standard IEC 60255, IEC 61000-4, IEC 60068-2, EN 50081-2
Weight 0.6kg(MCT 0.35kg)
Dimension Main unit 148(W) × 100(H) × 74(D) mm
MCT 151(W) × 55(H) × 33(D) mm
* D-Time(Delay time) : It is delay time for IMC-III start during motor start time
* O-time (Operating delay time) : When over current generates more then setting current, that makes it delayed until IMC-III operated.
Rating
www.dienhathe.xyz
www.dienhathe.vn
9. IMC-III
O
Type Specification RemarkContents
RemarkOperating condition Time
O-9
Motor protection
Over Inverse Over 110% setting current 1~60s/1s 600% standard operating time
current Definite time Over 105% setting current 1~60s/1s Delay time 1~200s
Phase fault Over 70% current phase unbalance Within 1.5s
Phase unbalance Current phase unbalance 30~50% Within 5s
Reverse phase Reverse the current phase Within 0.1s Over 110% minimum ratings
Under current Rating current 30~70% Within 3s
Holding Stall Rating current 150~300% Within 5s
Detection after over current setting time
Locked rotor Rating current 200~700% Within 0.5s
Ground fault The current rating 0.1~2.5A setting 0.05~1.0s Ground fault delay operation
Pre-alarm Over 120% setting value Bar-LED blinking
Communication function
Protocol Modbus_RTU
Communication RS-485
Modbus Operation Differential
/ Baud rate 9600, 19200, 38400bps
RS-485 Length Max 1.2km Different from local situation
Cable RS-485 Shielded twist 2-pair cable
Transmission Half-duplex
Max in/Output voltage -7V ~ +12V
Contents
Sequence function
Remark
Operating type Direct operation Non-reversible direct operation
Y-△△ operation Y operation time 1~120s/1s
Y-△△ switching time 0.05, 0.1, 0.2s
Forward / Reverse operating Reversible direct operation
Reactor Reactor time 1~120s/1s
Inverter Inverter delayed time ON 1sec/0.1sec
Instantaneous Compensation time OFF 1~10s /1s
under voltage Re-operation delay time 0~300s /1s
compensation Under voltage detection (Rating control voltage × 65%) ± 10%
Recovering voltage detection (Rating control voltage × 75%) ± 10%
User contact Normal Normal mode
point mode Time delay ON delay
0~300s/1s
OFF delay
Flow switch ON delay
Comparing
OFF delay 0~300s/1s
Timer � ON delay timer
Comparing timer
Remote control Local LOP(Local Operation Panel)
MCC Motor Control Center
Auto PLC, DDC, DCS auto operation
W/L Water Level
Remote Modbus/RS-485 communication
www.dienhathe.xyz
www.dienhathe.vn
10. O-10
Intelligent Motor Controller
Main function description
Protection function
Overload protection(49)
Overload protection function senses current which is flowing on
the motor, and tracing the heat, and then protects. When the
heat capacity approaches, it generates overload trip, and this
heat capacity is calculated by characteristic curve and I²t.
Class1 ~Class60 overload characteristic curve is determined by
setting motor’s rated current, considering motor operating time,
setting operating time 1s~60s by according to 600% of setting
current.
When you choose the definite time characteristic, it starts over
current after Delayed time and if over current keeps applying
over Operation-time, it generates trip.
Stall/Locked rotor protection (48/51LR)
When the fault generates like locked rotor, the mechanical units
like pump, fan can be damaged easily. IMC-III prohibits stall, locked rotor, start failure, over
current and open the circuit when the current increases rapidly, load torque exceeds the motor
torque. But IMC-III has delayed time, it can not be tripped by operating current.
Under current protection(37)
Protection of no-load condition by operating axis separation , maintenance of pump noload and
in case of motor frigidus method, it can be used for protection of operating terminal overload.
It’s possible to set 30~70% of rated current, it operates within 3s.
Phase fail/Phase unbalance protection-47P
If the phase fail generates due to the motor internal fault or wiring problem. Motor cannot
operate or keep operating,
In this case, high reverse phase current applied, so motor can be damaged. IMC-III will trip
within 1.5s when the unbalance rate is over 70%. IMC-III will trip within 5s, when the unbalance
rate is over 30~50%. However,
when you applied 1p motor, it can not be detected phase-fail and unbalance. User has to be off in this case.
Reverse phase protection
Reverse phase protection prohibits motor reverse rotation when the phase of current changed each other.
IMC-III will trip within 0.1s, when the phase changed each other by comparing 3phase difference.
IMC-III can detect the reverse phase over minimum 110%, of setting current, during motor operation.
When the 1p motor is applied, it can not be detected reverse phase. User has to be off in this case.
Ground fault protection-51G
This function protects fault circuit by detecting earth fault, ground fault. And this function also protects second
fault (short circuit, electric shock) by detecting earth fault current. User has to set the current value, operating time
differently by protection system. Ground fault sensing current can be set 100~2500mA, and ground fault
operating time can be set 0.05s~1s. The separate ZCT (Zero phase current transformer) is used for
detecting ground fault current. However, when the IMC-III start inverter operation, it can not be protected
ground fault Protection. User has to be OFF.
current current
sec
sec
current
sec
<Inverse time> <Definite time>
www.dienhathe.xyz
www.dienhathe.vn
11. IMC-III
O
O-11
* When the external trip generates it will be OFF simultaneously irrespective of ON/OFF Delay Timer
Fault analysis, fault recording
User can check fault current value by UP/DOWN button and fault
recording can be checked by [ESC + ENT].
Time delay(t-d) mode
1) After ON operation, it passed ON delay time, 88M will be ON
and motor will operate.
2) After OFF operation, it passed OFF delay time, 88M will be
OFF and motor will be stopped.
External trip input
Self-diagnostic function
Flow switch (F-S) mode
Motor start
1) If F/S (FlowSwitch) is applied within setting comparison timer-ON
Delay timer after ON operation. After ON delay timer, motor will
operate.
2) If F/S is not applied, ON will be canceled, “t2-F” will be
indicated, will maintain OFF condition.
Motor operation
1) During motor operation, if F/S input is out of state, 88M will be
OFF, Motor will stop.
2) At this time, the comparison timer will operate, and if F/S is
reapplied within setting comparison timer-ON Delay timer, motor
will be re-started in normal Condition
3) If F/S is not reapplied within comparison timer-ON Delay timer, “t2-
F” will be indicated, motor keep stopping.
4) When user operates OFF, 88M will be OFF, after OFF delay
time, motor will stopped.
ex) When the T1 timer : 1s, T2 Timer : 10s, T3 Timer 5s set, F/S
re-applied time after F/S OFF has to be within 10s-5s = 5s and
‘t2-F’ will not indicated, motor will be re-started in normal
condition.
Note) Comparison timer has to be set more than ON Delay timer.
Overload Under current
Phase fault Phase unbalance
Locked rotor Stall
Reverse phase Ground fault
In case of no F/S input
within setting time
When it passed the
operating setting time
When MC condition input contact point is ON after
output contact OFF operating.
When MC condition input contact point is OFF,
after output contact point ON operating.
When the external input contact point““FOR””,
REV””is applied at once.
EEPROM Fault
www.dienhathe.xyz
www.dienhathe.vn
12. O-12
Intelligent Motor Controller
Operation and setting
Front view
MCT
IMC-III main unit
Rear view Setting method
Current &
Information
Operation mode
LED
R, S, T Phase
indication
Setting value
choice & move to
contents
Setting store
button
Condition LED
Move to previous
button
Malfunction
preventing
Cover
Standard unit &
load ratings
Indication LED
of load ratings
Motor condition
LED
Motor start
button
Operation mode
button
Communication
connection CON
MCT connection
CON
Trip Reset button
RX0
RX1
TX0
TX1
4~20mA pole
pole
1) The first stage will be indicated maximum current in
znormal condition.
2) When the UP/DOWN button is pushed, A, B, C group is
indicated.
3) When user push the ENT button after selecting group, it
move to the detail setting contents.
4) After selecting contents by pushing UP/DOWN button, if
user push the ENT button, the setting value will be
stored.
5) When UP/DOWN button is pushed, the setting value
will change, so that after selecting contents, if you push
the ENT button , setting value will be stored.
6) After setting, if user push the ESC button, IMC-III will be
returned normal operating condition.
Note) 1. Pls note that setting value can be changed during motor operation.
2. If user did not operate for 10S , Setting value and group setting contents will
returned to current indication mode automatically.
Indication of trip
analysis,
Indication of
setting group.
Rating type
setting S/W
www.dienhathe.xyz
www.dienhathe.vn
13. IMC-III
O
Setting valueGroup
O-13
SettingNo.
Characteristic
Inu/dEF Inu Inverse/Definite time selection(Over current protection)
Operating time
1~60/1sec 60
In case of definite time,
(Over current protection) motor operating time
Operating delayed time
1~200/1sec 200(Over current protection)
Setting of rated current 0.5~6/0.1(A), 5~60/1(A) 6 / 60 6/60A selection
CT ratio 0.25, 0.5, 1~200/1 1 Impossible to set in case of selection 60A
Start type selection dir/y-d/F-r/Ind/Iut dir Direct, Y-�. Reactor, Inverter start
Y operation time 1~120/1sec
5 Reactor start time Inverter start delayed time
(Inverter start :0) (0~1sec)
Y-D switching time 0.05, 0.1, 0.2(sec) 0.2
Short time power off
OFF, 1~10/1sec OFFcompensation time
Re-start time 0~300/1sec -
9. It can be indicated only in case of short
time power stop compensation time
Lock protection OFF, 200~700/100(%) OFF
Stall protection OFF, 150, 200, 300(%) OFF
Phase-fault
OFF/On On
protection enabled
Unbalance protection OFF, 30, 40, 50(%) OFF
Reverse phase protection OFF/On OFF Only during operation
Under current protection OFF, 30~70/5(%) OFF
Ground fault protection OFF/On OFF OFF setting in case of inverter start
Ground fault
0.1, 0.2, 0.5, 1.0, 1.5, 2.0, 2.5(A) 0.1
operation current
Ground fault
0.05, 0.1~1.0/0.1sec 0.05
7. Indication by ground fault
operation time protection seleection
Ground fault delay OFF/On OFF
I/O state information 4-segment Notify the manual
Total operation time Total operation time checking
Time check, Day → hour, min
Setting disabled (Max.1year : 8760 hour)
Operation time Operation time checking
Time check, Operation time →Day → Hour, min
Setting disabled (Max 1year : 8760 hour)
Operation time setting OFF, 10~8760/10(H) OFF
After reached setting operation time,
indicating“OrH”
Contactor check OFF/On On
MC condition input check
(OFF→not indicated Err1,2)
User contact
nor/t-d/F-S nor Normal/Time delay/Flow switch
point mode
ON Delay Timer 0~300sec/1sec 0
In case of t-d, F-S mode selection,
OFF Delay Timer 0~300sec/1sec 0
it can be set
Comparison timer 0~300sec/1sec 0 In case of F-S mode selection, it can be set
Auto- returning OFF, 1~20min/1min OFF
Communication address 1~255 1 Only indication of communication model
Communication Spped 96, 192, 384 96 bps(×100)
SWAP OFF/On On
Floating data frame reverse
(3, 4, 1, 2) selection
Default value Remark
A.grpBasicsettingB.grpProtectionfunctionC.grpAdditionalfunction
Indication
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
11
12
13
www.dienhathe.xyz
www.dienhathe.vn
14. O-14
Intelligent Motor Controller
Operation and setting
3-phase current
circulation indication
Maximum phase
current indication
Rated current setting
1) IMC-III rated current can be selected 6A(0.5~6A), 60A(5~60A)
2) To select the rated current.
① Move to the slide switch to the rated current side in the rear side
② User has to switch the IMC-III power OFF →→ ON
③ Set the detail current by moving from A setting group to [4.r-C] group in the front side.
- Setting by motor setting current
- After finishing motor starting, set the 110~115% of real load current in the load operation condition.
Operating time setting
1) It can be set 1~60s in the A group in [2.O-t]
① In case of selecting inverse time in the [1.CHA]
- Setting operation time is 600% standard of rated current
② In case of selecting the definite time
- The standard is over 105% of rated current.
- User has to set the operation delayed time 1~200s In the [3.d-t] considering motor operating time.
Special function key
Turn the heating capacity into clear and return by force
IMC-III inverse time protects overload fault by sensing the applied current on the motor, trace heating condition of motor. Motor has
heating capacity until completed cold status even if . motor stopped. IMC-III accumulates heating capacity values similar with motor. In
case of continuous re-start, or generating the trip, it can be tripped by acknowledgement Hot curve through the cumulated heating
capacity,
Fault recording
IMC-III provides fault recording function even if power is OFF. If user push the + button, user can check the Fault analysis and
fault current value. If user push the button, fault analysis and fault recording will be deleted.
If there is no string data, it will be indicated “non” And then if user push the + button, it will come back to normal mode.
Transfer to current indication mode.
If user push the button for 2 seconds, it will come back to current indication mode.
RESET
RESET
ESC
ESC
Note) If user push the RESET button for over 10s, IMC-III will come
back first manufacturing status. At this time, user has to know
that setting and storing value is deleted and comes back first
manufacturing status.
Note) Don’t change the switch during the operation.
�� Load under 0.5A
- Set the CT ratio 0.5 or 0.25 in the [6.ctr]
- MCT cable penetration increase from 2 times to 4 times
- Rated current setting range : 0.25~3A(2 times), 0.125~1.5A (4 times)
�� Over 60A load
- Usage of external CT
- CT ratio (1~200) : Maximum 1000A
Information
If user want to re-start even if damaged to motor, push the + button. in conclusion,
cumulative heating capacity remove and can be reset.
Information
STOP RESET
www.dienhathe.xyz
www.dienhathe.vn
15. IMC-III
O
O-15
Total operation time
Total operation time check : →→ →→ day →→ →→ Hour minute
ex) If total operation time is 50hours 50 minutes : → → 2 days → → 2.50(2 hours 50 minutes)
Operation time →→ →→ Total operation time →→ →→ converse day →→ →→ Extra hour, minutes
ex) If operation time is 50 hours 50minutes : → → 50 hours → → 2days → → 2.50 (2 hours 50 minutes)
Operation mode handling method
Local operation panel mode
The local operation mode is the highest priority mode, When the emergency situation generates,
it can control motor in the local site. Only in case of closing switch to the local site, motor can be controlled.
At that time, Local LED of IMC-III is lighting on, can not be controlled in another modes.
Motor control center mode
This mode is possible to operate in the IMC-III of MCC panel. If MCC LED is lighting up
by pushing the button, it’s possible to control motor in the IMC-III.
At this time, it can not be controlled by in AUTO.
Auto-PLC automatic operation mode.
This mode can provides automatic operation and remote control by PLC, DDC, DCS.
If auto / Rem LED lights up, motor is controlled by automatic operation.
It’s possible to operate without converting mode in the IMC-III of MCC by operation priority.
And when the motor controls, operation mode convert to MCC.
W/L- Water level automatic operation mode
This mode is for automatic operation and remote control by water changes.
If W/L LED lights up by operating button of IMC-III it can be controlled through the automatic operation.
It’s possible to operate automatically through the PLC, DDC.
It’s also possible to operate without converting mode in the IMC-III of MCC by operation priority.
And when the motor controls, operation mode convert to MCC.
Note) In case of using with Auto mode, the user has to compose of interlock circuit by using status output contact point.
Remote- communication operation mode
This mode is for remote monitoring control by Modbus, RS-485. If Auto/Remote LED lights up,
It’s possible to communicate with Modbus/RS-485 and also check the 3phase value, fault value,
various data. It’s also possible to operate without converting mode in the IMC-III of MCC
by operation priority. And when the motor controls, operation mode convert to MCC.
Note) 4~20mA output model can check only current Value through the Analog communication(4~20mA)
Operation priority : Local > MCC > Auto, W/L > Remote
www.dienhathe.xyz
www.dienhathe.vn
19. IMC-III
OTerminal number
Terminal
No
O-19
S/V valve start(Direct)
* S/V : Solenoid Valve
① If ON S/W applied, S/V(Solenoid Valve) becomes ON, OFF Delay Timer becomesON.
② If F/S (Flow Switch) applied within [T2-T3] time, ON Delay timer becomes ON.
③ If becomes ON, comparison timer becomes OFF after setting time. And then Motor will operate because 88MX becomes ON.
④ At this time, if F/S does not apply within setting [T2-T3], ON will be canceled and then“t2-F”will be indicated.
⑤ Comparison timer has to be set more than ON Delay Timer , user has to consider time margin until F/S application.
⑥ If OFF s/w applied for motor stop, S/V and motor will be OFF delay same as time
⑦ If F/S input is removed during motor operation, 88MX will be OFF, motor will be stopped. At this time S/V will be OFF.
T1
T3
T3 T2
T2 T3
T1
1 LOP selection input 14 Y-start/Reverse rotation/Reactor/Bypass contact point output
2 COM1(1, 3, 4, 5, 6) 15 VCC1(12, 13, 14, 16)
3 ON input 16 LOP condition output
4 Reverse rotation ON input(Bypass) 17 Auto condition output
5 Stop input 18 Water level condition output
6 Reset input 19 TRIP output(1a)
7 MC condition input 20 VCC2(17, 18, 19, 21, 22)
8 F-S mode input 21 ON delay timer output(t-d, F-S mode)
9 COM2(7, 8, 10, 11) 22 OFF delay timer output(t-d, F-S mode)
10 External trip1 input 23 Control power(AC110V or 220V)
11 External trip2 output 24 Control power(AC 110V or 220V)
12 ON output 25 ZCT input(k)
13 △start/Inverter contact output 26 ZCT input(ℓ)
* Normal mode
20-21 : Operation alarm(“OrH”) output
20-22 : not in use
Terminal
No
ExplanationExplanation
*
*
[
* INPUT (220VAC)
1,3,4,5,6-2 (COM1)
7,8,10,11-9 (COM2)
* OUTPUT
12,13,14,16-15 (VCC1)
17,18,19,21,22-20 (VCC2)
* Comm. Port
RS-485 4~20mA
RXD0 (-)
RXD1 (+)
TXD0
TXD1
www.dienhathe.xyz
www.dienhathe.vn
22. 3CTModel
Dimension(mm)
Contents
O-22
Intelligent Motor Controller
Accessories
SCT(3CT)
64 82
82 82 82
8282
256
65
6465
32.553
65
∅
5
27.5
1CT 3CT(Combination of 1CT 3EA)
Dimension
Note) 1. This product is only for EMPR, IMC, user must not use for other service
2. Pls order each 3EA with IMC-III, because this product is 1CT type.
In case of MCT combination
256
120
ZCT(Zero-phase current transformer)
LZT-025(I) 25 0.5
LZT-040(I) 40 200mA/0.1mA 0.8
LZT-080(I) 80 0.4
Weight
(kg)
Inside diameter
(mm)
Zero phase current
transformer ratio
LZT-025(I) 81 43 43.5 68 81 25
LZT-040(I) 101 43 53.5 88 101 40
LZT-080(I) 146 43 76 133 146 80
A B C D E ∅∅F
Note) This product is only for IMC, and user has to use this ZCT for protection ground fault.
Ratings
SCT-100 100:5A
Current SCT-150 150:5A
transformer SCT-200 200:5A
ratio SCT-300 300:5A
SCT-400 400:5A
Class 1.0
Burden 5VA
Insulated voltage AC 600V
Insulated internal pressure 2kV
Insulation resistance 10MΪ(DC 500V Megger)
Mounting Panel
www.dienhathe.xyz
www.dienhathe.vn
23. IMC-III
O
Operation and control
power
O-23
Dimension & Ordering
IMC-III main unit
Dimensions
MCT
NO
Normal
(No communication)
M485 Modbus/RS-485
A420 Analog 4~20mA
Item MCT cable length
2M 2m
4M 4m
AC 110V
AC 220V
50/60Hz
Frequency
Ordering
2M AC 110V 50/60HzIMC-III NO
www.dienhathe.xyz
www.dienhathe.vn