The PLZ-5WH2 high power DC electronic load series is where durable, reliable ingenuity meets multifunctional and high power design. Providing 5 variety of power range line-ups, from 1 kW bench top style model to high power model that can sink up to 20 kW of power in a single unit. Possible to easily selects applicable power range depends on the load. Load simulation can be achieved faster than ever before thanks to the reliable, high speed design of the PLZ-5WH current control circuits. Accurate current measures can be made with extremely high setting resolution. A color LCD display allows for highly visible, user-friendly front panel operation. RS232C, USB, and LAN digital interfaces are included as standard for simple integration into any system.
Operation Modes
The following five operation modes are available on the PLZ-5WH2. In addition, available to set in operation modes other than CV mode, the “UVPL*” setting keep the voltage less than UVP setting by controlling the current and the “UVPT” setting loads off by applying a current to reach the target setting voltage.
Constant current (CC) mode When a current value is specified, the current is kept at that value even when the voltage changes.
Constant resistance (CR) mode When a conductance value is specified, the product sinks current proportio-nal to the voltage variation by using the value as a proportionality constant.
Constant voltage (CV) mode When a voltage value is specified, the product runs the current so that the voltage is kept at that value.
Constant power (CP) mode When a power value is specified, the product runs the current so that the power is kept at that value.
Arbitrary I-V charac-teristics (ARB) mode The desired load characteristics can be set by specifying multiple arbitrary voltage values and current values as I-V characteristics.
* "UVPL" is the "+CV mode" in PLZ-5W series
https://www.n-denkei.com/singapore/inquiry/
The document describes a multifunctional electronic load called the PLZ-5W series. It can operate from 1V to 150V with a maximum slew rate of 60A/μs. It includes features like arbitrary I-V curve settings, sequence programming of up to 10,000 steps, impedance measurement, and various communication interfaces. The PLZ-5W series improves on previous models with a high-resolution color LCD, wider voltage range, and new ARB mode for customizing I-V profiles.
The PWR-01 is a series of high performance, multifunctional, compact, wide-range DC power supplies. It consists of 16 models in total with 4 maximum voltage outputs (L, ML, MH, and H) and 4 maximum power outputs (400 W, 800 W, 1200 W and 2000 W). The series is equipped with LAN (LXI), USB, and RS232C as standard interfaces that are essential for system integration. The PWR-01 also features front-facing output terminals, variable internal resistance, bleeder ON/OFF functions, CC/CV priority switching function, synchronized operation, various protections, and programmable internal memory.
https://www.n-denkei.com/singapore/inquiry/
The document provides information on program controllers for operating RCS2 series actuators. The controllers can handle various controls for one or two axes. They support up to 20,000 positioning points and allow for functions like push-motion operation, teaching operation, and path operations when two axes are connected. The document outlines the specifications and I/O functions of the SSEL controller model.
Kikusui DC power supply high power capacity 4kW, 8kW
Up to 1500V output
Programmable
For Solar panel testing Electric vehicle battery testing
https://www.n-denkei.com/singapore/inquiry/
The document describes a PSEL controller for operating RCP3/RCP2 series actuators. The controller combines various control functions into a single unit. It can handle operation and communication with one controller for up to two axes. It supports up to 1500 positioning points and functions like path operations and teaching operation.
PBZ Series Intelligent Bi-Polar Power Supplies
The PBZ series is a bipolar type DC regulated power source that can continuously change both + and – polarities passing through 0 without changing the output terminal.
By adopting a “Switching + Linear” system, the PBZ is able to realize both drastic weight reduction as well as high speed and low noise operation. Since operation covers 4 quadrants, power can be both supplied (source) and absorbed (sink). The PBZ can also drive inductive or capacitive loads. The unit also equips a signal generator function which enables waveform and sequence creation. The PBZ is also capable of synchronized operation which is required for voltage variation tests, and it can also be expanded for large current applications through master-slave parallel operation.
This document summarizes a DC voltage current source/monitor device that is suitable for testing high-voltage semiconductors and LED luminaires. The device can output voltages up to +250V and currents up to ±320mA with high accuracy of ±0.02%. It has various measurement and sweep functions including pulse measurement with a minimum pulse width of 50μs. The device also has a suspend function to control the output status and prevent transient currents when connecting voltage sources.
The document provides information about SCON controllers, including:
- There are standard and network specifications, with incremental and absolute options. Only incremental is available for pulse train input.
- It lists motor, encoder, I/O cable length, power/voltage options. Network connection specifications are also optional.
- Control can be performed via PIO, pulse train, or connecting to a field network depending on the specification. Positioning of up to 512 points is possible in positioner or solenoid valve modes.
The document describes a multifunctional electronic load called the PLZ-5W series. It can operate from 1V to 150V with a maximum slew rate of 60A/μs. It includes features like arbitrary I-V curve settings, sequence programming of up to 10,000 steps, impedance measurement, and various communication interfaces. The PLZ-5W series improves on previous models with a high-resolution color LCD, wider voltage range, and new ARB mode for customizing I-V profiles.
The PWR-01 is a series of high performance, multifunctional, compact, wide-range DC power supplies. It consists of 16 models in total with 4 maximum voltage outputs (L, ML, MH, and H) and 4 maximum power outputs (400 W, 800 W, 1200 W and 2000 W). The series is equipped with LAN (LXI), USB, and RS232C as standard interfaces that are essential for system integration. The PWR-01 also features front-facing output terminals, variable internal resistance, bleeder ON/OFF functions, CC/CV priority switching function, synchronized operation, various protections, and programmable internal memory.
https://www.n-denkei.com/singapore/inquiry/
The document provides information on program controllers for operating RCS2 series actuators. The controllers can handle various controls for one or two axes. They support up to 20,000 positioning points and allow for functions like push-motion operation, teaching operation, and path operations when two axes are connected. The document outlines the specifications and I/O functions of the SSEL controller model.
Kikusui DC power supply high power capacity 4kW, 8kW
Up to 1500V output
Programmable
For Solar panel testing Electric vehicle battery testing
https://www.n-denkei.com/singapore/inquiry/
The document describes a PSEL controller for operating RCP3/RCP2 series actuators. The controller combines various control functions into a single unit. It can handle operation and communication with one controller for up to two axes. It supports up to 1500 positioning points and functions like path operations and teaching operation.
PBZ Series Intelligent Bi-Polar Power Supplies
The PBZ series is a bipolar type DC regulated power source that can continuously change both + and – polarities passing through 0 without changing the output terminal.
By adopting a “Switching + Linear” system, the PBZ is able to realize both drastic weight reduction as well as high speed and low noise operation. Since operation covers 4 quadrants, power can be both supplied (source) and absorbed (sink). The PBZ can also drive inductive or capacitive loads. The unit also equips a signal generator function which enables waveform and sequence creation. The PBZ is also capable of synchronized operation which is required for voltage variation tests, and it can also be expanded for large current applications through master-slave parallel operation.
This document summarizes a DC voltage current source/monitor device that is suitable for testing high-voltage semiconductors and LED luminaires. The device can output voltages up to +250V and currents up to ±320mA with high accuracy of ±0.02%. It has various measurement and sweep functions including pulse measurement with a minimum pulse width of 50μs. The device also has a suspend function to control the output status and prevent transient currents when connecting voltage sources.
The document provides information about SCON controllers, including:
- There are standard and network specifications, with incremental and absolute options. Only incremental is available for pulse train input.
- It lists motor, encoder, I/O cable length, power/voltage options. Network connection specifications are also optional.
- Control can be performed via PIO, pulse train, or connecting to a field network depending on the specification. Positioning of up to 512 points is possible in positioner or solenoid valve modes.
The document describes an analog servo drive called the AZBE60A8. It is designed to drive brushless and brushed DC motors at high switching frequencies. Key specifications include a peak current of 60A, continuous current of 30A, and operating voltage range of 10-80VDC. It has protection against overvoltage, undervoltage, overcurrent and more. It can utilize encoder, hall sensor, or tachometer feedback and supports various motor and operation modes.
The document describes the PRO-A08V48 programmable servo drive. It is a compact drive solution for rotary or linear brushless, stepper or PMDC brush motors with power up to 385W and 48V nominal voltage. It integrates advanced motor control and motion control functionality. The drive can operate autonomously or as part of a multi-axis distributed control solution. It is programmable via ElectroCraft's MotionPRO Suite software.
The document discusses the P-Driver pulse-train input driver that enables flexible control of IAI's ROBO CYLINDER actuators and single-axis robots. The P-Driver can control a wide range of actuators with various options and functions including torque limiting, brake control, feedback, and feed-forward control. It connects to actuators, provides power connections, and includes status indicators and connectors for communication, I/O signals, and encoders.
The document provides specifications for the AZBE25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies up to 25A continuous current. It has features like four quadrant regenerative operation, direct board integration, encoder and tachometer feedback support, and hardware protections. The drive requires only a single DC power supply and complies with safety and emissions standards.
The document describes the Analog Servo Drive AZXBH6C20. It is designed to drive brushless DC motors at high switching frequencies and integrate directly into PCBs. It provides 6A of continuous current from 40-175VDC supply and is protected against over-voltage, over-current, and other faults. The drive supports Hall sensor or tachometer feedback and operates in various modes including current and velocity control. It has a wide operating temperature range from -40°C to 85°C.
The document summarizes an ElectroCraft PRO Series Programmable Servo Drive called the PRO-A04V36. It is a compact, cost-effective drive solution for controlling rotary or linear brushless, stepper, or PMDC brush motors of up to 144W power. The drive integrates advanced motor control and motion control functionality. It can operate autonomously or as part of a distributed motion control system and is programmable via the MotionPRO Suite interface.
The document provides specifications for the AZBH25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies. It has a peak current of 25A, continuous current of 12.5A, and operates on a DC supply voltage of 40-175VDC. The drive provides various protection features and supports different feedback and operation modes.
The document describes a program controller for operating RCA2/RCA series actuators. The controller can handle various controls for a single or dual axis system. It supports up to 1500 positioning points and can perform functions like linear/arc interpolation, path operations, and teaching operations through a programmed control mode or PLC input signals in a positioner mode. Key specifications of the controller include support for up to two motor axes, 1500 positioning points, and integrated operation and communication capabilities.
This document provides information on the M/VTM Series Servo Drive AB100C200. It summarizes the drive's key specifications including its power range, features, modes of operation, command sources, feedback supported, and agency approvals. The document also includes block diagrams, pinout diagrams, switch settings, and other technical details.
The AZBE40A8 is a PWM servo drive designed to drive brushless and brushed DC motors. It can provide a peak current of 40A and continuous current of 20A, with a supply voltage range of 10-80VDC. The drive is fully protected against over-voltage, under-voltage, over-current and other faults. It supports various feedback and operation modes including encoder velocity control.
The document describes the Analog Servo Drive B25A20FAC. It is designed to drive brushless DC motors with a peak current of 25A and continuous current of 12.5A. It can operate on an AC supply voltage of 30-130VAC. The drive features adjustable current limits and gains, as well as multiple operating modes that can be selected with DIP switches including current mode, open loop, and hall velocity mode. It provides protection against overloads and includes status monitoring outputs.
This document provides specifications for the RCP2-BA6/BA6U ROBO Cylinder. It includes details on the speed and load capacity which decreases at higher speeds. It also lists the stroke lengths from 500mm to 1000mm and compatible controller options for operating the cylinder. Technical drawings and dimensions are provided for the cylinder housing.
The DCM8054/8027 is a stepper motor drive that can operate between 20-80VDC with output currents up to 5.5A/2.8A. It uses advanced DSP control algorithms to provide smooth motor movement. It has features like anti-resonance control, microstepping, soft-start, input isolation, and selection of pulse modes, resolutions, and current levels through onboard switches and jumpers. The document provides details on specifications, connections, settings, and applications for the stepper motor drive.
This servo drive is designed to drive brushless DC motors at high power levels. It can operate in various modes including current, velocity, and duty cycle modes. It has protections against overheating, overcurrent and other faults. It is compliant with various safety standards and has adjustable parameters, feedback options and I/O for control and monitoring.
This servo drive amplifier can provide up to 250A of peak current and 150A of continuous current. It is designed to drive brushless DC motors and interface with digital controllers. It has protection against overheating, overcurrent and other faults. Operating modes include current control, velocity control using encoders or Hall sensors, and it can drive brushed or brushless motors.
Catalog biến tần Frenic Lift - Fuji Electric mới nhất 2019CTY TNHH HẠO PHƯƠNG
Catalog biến tần Frenic Lift do hãng Fuji Electric Nhật bản phát hành, mô tả đầy đủ về dòng biến tần Frenic Lift gồm:
Thông số kỹ thuật cơ bản
Tính năng
Sơ đồ đấu nối, thông tin các chân điều khiển
Kích thước
Các hàm cài đặt
Biến tần Frenic-Lift với hệ số quá tải lên đến 200%/10s cùng với đó là tuổi thọ và độ bền lâu dài (tuổi thọ DC bus lên đến 10 năm). ACR: 500Hz, hơn 5 lần so với model trước ( so sán với dòng UD).
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng catalog biến tần Frenic ACE Mới Nhất 2019 . Dòng biến tần chất lượng và kinh tế nhất của hãng Fuji Electric hiện nay, được sản xuất tại Thái Lan và dành riêng cho khu vực Đông Nam Á.
The document describes an RTL Series digital servo drive that provides brushless motor control. It combines CANopen networking with fully digital control of brushless or brush motors from single or three-phase power. It supports motion profiles including position, velocity, torque and homing modes according to CANopen standards. It has configurable digital and analog inputs and outputs for interfacing with motors, encoders and controls.
The AZXBH15A8 is a PWM servo drive designed to drive brushless and brushed DC motors at high switching frequencies. It can provide up to 15A of peak current and 7.5A of continuous current from a 10-80VDC power supply. The drive is protected against overvoltage, undervoltage, overcurrent, overheating and other faults. It supports hall sensor or tachometer feedback and operates in various modes including current and velocity control.
The PCR-WE/WE2 is a series of multifunctional switching AC power supplies that combines accurate, high-power output with an ultra-compact design. The 15 model line-up ranges from 1 kVA to 36 kVA AC/DC with single & 3 phase variable output from 6 kVA and up. The PCR-WE/WE2 also features a regenerative mode*1 that can drastically reduce power consumption and cut operating costs. The PCR-WE/WE2 also supports mix-and-match parallel operation*2 up to 144 kVA for large-scale test systems. Output frequency up to 5 kHz is also available with all models, which is critical for AC applications in avionic industries.
https://www.n-denkei.com/singapore/inquiry/
The document discusses a high-end multi-functional electronic load called the Load Station Series (300W/1000W). It has several key features:
1) It can precisely set current waveforms on a color LCD and has dynamic, sequence, and sweep modes for testing.
2) It has a high-speed current control technology that eliminates overshoot and delivers a smooth current transition.
3) Unlike conventional loads, it acts as a resistive load from 0V so there is no delay between current and voltage, allowing it to test low-voltage devices.
4) It has options like a ripple and noise measurement module, can be remotely controlled, and its units can be connected in
This document summarizes the features of the KG Load Station Series 300W/1000W electronic loads. It has a revolutionary UI like an oscilloscope for easy operation. It realizes less 35% weight than previous models. It can operate just like a resistor with no minimum voltage requirement. It has high speed current control and 4 models from 300W to 1000W in 125V and 500V ranges.
The document describes an analog servo drive called the AZBE60A8. It is designed to drive brushless and brushed DC motors at high switching frequencies. Key specifications include a peak current of 60A, continuous current of 30A, and operating voltage range of 10-80VDC. It has protection against overvoltage, undervoltage, overcurrent and more. It can utilize encoder, hall sensor, or tachometer feedback and supports various motor and operation modes.
The document describes the PRO-A08V48 programmable servo drive. It is a compact drive solution for rotary or linear brushless, stepper or PMDC brush motors with power up to 385W and 48V nominal voltage. It integrates advanced motor control and motion control functionality. The drive can operate autonomously or as part of a multi-axis distributed control solution. It is programmable via ElectroCraft's MotionPRO Suite software.
The document discusses the P-Driver pulse-train input driver that enables flexible control of IAI's ROBO CYLINDER actuators and single-axis robots. The P-Driver can control a wide range of actuators with various options and functions including torque limiting, brake control, feedback, and feed-forward control. It connects to actuators, provides power connections, and includes status indicators and connectors for communication, I/O signals, and encoders.
The document provides specifications for the AZBE25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies up to 25A continuous current. It has features like four quadrant regenerative operation, direct board integration, encoder and tachometer feedback support, and hardware protections. The drive requires only a single DC power supply and complies with safety and emissions standards.
The document describes the Analog Servo Drive AZXBH6C20. It is designed to drive brushless DC motors at high switching frequencies and integrate directly into PCBs. It provides 6A of continuous current from 40-175VDC supply and is protected against over-voltage, over-current, and other faults. The drive supports Hall sensor or tachometer feedback and operates in various modes including current and velocity control. It has a wide operating temperature range from -40°C to 85°C.
The document summarizes an ElectroCraft PRO Series Programmable Servo Drive called the PRO-A04V36. It is a compact, cost-effective drive solution for controlling rotary or linear brushless, stepper, or PMDC brush motors of up to 144W power. The drive integrates advanced motor control and motion control functionality. It can operate autonomously or as part of a distributed motion control system and is programmable via the MotionPRO Suite interface.
The document provides specifications for the AZBH25A20 analog servo drive. The drive is designed to drive brushless and brushed DC motors at high switching frequencies. It has a peak current of 25A, continuous current of 12.5A, and operates on a DC supply voltage of 40-175VDC. The drive provides various protection features and supports different feedback and operation modes.
The document describes a program controller for operating RCA2/RCA series actuators. The controller can handle various controls for a single or dual axis system. It supports up to 1500 positioning points and can perform functions like linear/arc interpolation, path operations, and teaching operations through a programmed control mode or PLC input signals in a positioner mode. Key specifications of the controller include support for up to two motor axes, 1500 positioning points, and integrated operation and communication capabilities.
This document provides information on the M/VTM Series Servo Drive AB100C200. It summarizes the drive's key specifications including its power range, features, modes of operation, command sources, feedback supported, and agency approvals. The document also includes block diagrams, pinout diagrams, switch settings, and other technical details.
The AZBE40A8 is a PWM servo drive designed to drive brushless and brushed DC motors. It can provide a peak current of 40A and continuous current of 20A, with a supply voltage range of 10-80VDC. The drive is fully protected against over-voltage, under-voltage, over-current and other faults. It supports various feedback and operation modes including encoder velocity control.
The document describes the Analog Servo Drive B25A20FAC. It is designed to drive brushless DC motors with a peak current of 25A and continuous current of 12.5A. It can operate on an AC supply voltage of 30-130VAC. The drive features adjustable current limits and gains, as well as multiple operating modes that can be selected with DIP switches including current mode, open loop, and hall velocity mode. It provides protection against overloads and includes status monitoring outputs.
This document provides specifications for the RCP2-BA6/BA6U ROBO Cylinder. It includes details on the speed and load capacity which decreases at higher speeds. It also lists the stroke lengths from 500mm to 1000mm and compatible controller options for operating the cylinder. Technical drawings and dimensions are provided for the cylinder housing.
The DCM8054/8027 is a stepper motor drive that can operate between 20-80VDC with output currents up to 5.5A/2.8A. It uses advanced DSP control algorithms to provide smooth motor movement. It has features like anti-resonance control, microstepping, soft-start, input isolation, and selection of pulse modes, resolutions, and current levels through onboard switches and jumpers. The document provides details on specifications, connections, settings, and applications for the stepper motor drive.
This servo drive is designed to drive brushless DC motors at high power levels. It can operate in various modes including current, velocity, and duty cycle modes. It has protections against overheating, overcurrent and other faults. It is compliant with various safety standards and has adjustable parameters, feedback options and I/O for control and monitoring.
This servo drive amplifier can provide up to 250A of peak current and 150A of continuous current. It is designed to drive brushless DC motors and interface with digital controllers. It has protection against overheating, overcurrent and other faults. Operating modes include current control, velocity control using encoders or Hall sensors, and it can drive brushed or brushless motors.
Catalog biến tần Frenic Lift - Fuji Electric mới nhất 2019CTY TNHH HẠO PHƯƠNG
Catalog biến tần Frenic Lift do hãng Fuji Electric Nhật bản phát hành, mô tả đầy đủ về dòng biến tần Frenic Lift gồm:
Thông số kỹ thuật cơ bản
Tính năng
Sơ đồ đấu nối, thông tin các chân điều khiển
Kích thước
Các hàm cài đặt
Biến tần Frenic-Lift với hệ số quá tải lên đến 200%/10s cùng với đó là tuổi thọ và độ bền lâu dài (tuổi thọ DC bus lên đến 10 năm). ACR: 500Hz, hơn 5 lần so với model trước ( so sán với dòng UD).
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng catalog biến tần Frenic ACE Mới Nhất 2019 . Dòng biến tần chất lượng và kinh tế nhất của hãng Fuji Electric hiện nay, được sản xuất tại Thái Lan và dành riêng cho khu vực Đông Nam Á.
The document describes an RTL Series digital servo drive that provides brushless motor control. It combines CANopen networking with fully digital control of brushless or brush motors from single or three-phase power. It supports motion profiles including position, velocity, torque and homing modes according to CANopen standards. It has configurable digital and analog inputs and outputs for interfacing with motors, encoders and controls.
The AZXBH15A8 is a PWM servo drive designed to drive brushless and brushed DC motors at high switching frequencies. It can provide up to 15A of peak current and 7.5A of continuous current from a 10-80VDC power supply. The drive is protected against overvoltage, undervoltage, overcurrent, overheating and other faults. It supports hall sensor or tachometer feedback and operates in various modes including current and velocity control.
The PCR-WE/WE2 is a series of multifunctional switching AC power supplies that combines accurate, high-power output with an ultra-compact design. The 15 model line-up ranges from 1 kVA to 36 kVA AC/DC with single & 3 phase variable output from 6 kVA and up. The PCR-WE/WE2 also features a regenerative mode*1 that can drastically reduce power consumption and cut operating costs. The PCR-WE/WE2 also supports mix-and-match parallel operation*2 up to 144 kVA for large-scale test systems. Output frequency up to 5 kHz is also available with all models, which is critical for AC applications in avionic industries.
https://www.n-denkei.com/singapore/inquiry/
The document discusses a high-end multi-functional electronic load called the Load Station Series (300W/1000W). It has several key features:
1) It can precisely set current waveforms on a color LCD and has dynamic, sequence, and sweep modes for testing.
2) It has a high-speed current control technology that eliminates overshoot and delivers a smooth current transition.
3) Unlike conventional loads, it acts as a resistive load from 0V so there is no delay between current and voltage, allowing it to test low-voltage devices.
4) It has options like a ripple and noise measurement module, can be remotely controlled, and its units can be connected in
This document summarizes the features of the KG Load Station Series 300W/1000W electronic loads. It has a revolutionary UI like an oscilloscope for easy operation. It realizes less 35% weight than previous models. It can operate just like a resistor with no minimum voltage requirement. It has high speed current control and 4 models from 300W to 1000W in 125V and 500V ranges.
The document discusses a high-end multi-functional electronic load called the Load Station Series (300W/1000W). It has several key features:
1) It can precisely set current waveforms on a color LCD and has a revolutionary oscilloscope-like user interface for ease of operation.
2) It has high-speed current control technology that eliminates overshoot and delivers an ideal current shape.
3) It offers flexible operation modes including constant current, constant resistance, constant power, constant voltage, external control, and sequence mode. Accessories like a ripple and noise measurement module are also available.
4) The lightweight and compact design incorporates a large LCD, memory functions, multi-
Bộ lưu điện ups gtec chính hãng Italia được cung cấp và phân phối độc quyền tại Việt Nam bởi Công ty TNHH Kỹ Thuật VBS. Hiện nay Bộ lưu điện ups đang chiếm lĩnh thị trường nguồn điện dự phòng tại việt nam trong thời kỳ công nghệ 4.0.
https://ups-gtec.com/
The document describes a servo drive model AVB100C200 that is designed to drive brushless DC motors for vehicle applications. It can interface with digital controllers or operate independently, accepts various feedback types, and has adjustable parameters. The drive has overcurrent, overvoltage, and other protections. It is compliant with various safety and environmental standards.
This document provides specifications for the M/VTM Series Servo Drive AVB250A060. It is designed to drive brushless DC motors for vehicle applications with a peak current of 250A and continuous current of 150A. It has adjustable parameters, fault protection, and can accept various command and feedback inputs. It is compliant with various safety and environmental standards.
The document describes the M/VTM Series Servo Drive AVB200A100. It is designed to drive brushless DC motors for vehicle applications with a peak current of 200A and continuous current of 125A. It can interface with digital controllers or operate independently, accepting various command and feedback inputs. Key features include adjustable parameters, operating mode selection, and safety protections.
This document provides specifications for the M/VTM Series Servo Drive AVB125A200. It is designed to drive brushless DC motors for vehicle applications with a peak current of 125A and continuous current of 80A. It accepts analog and potentiometer command inputs and feedback from Hall sensors, encoders, or tachometers. Modes of operation include current, voltage, velocity control and more which are selected using onboard DIP switches and potentiometers.
The document describes an analog servo drive that:
- Can provide up to 60A of peak current and 30A of continuous current from a 60-400VDC power supply.
- Includes protection against overvoltage, overcurrent, overheating and other faults.
- Can be controlled via a ±10V analog command and supports Hall, encoder and tachometer feedback.
- Has adjustable current limits, acceleration/deceleration rates, and other parameters via onboard potentiometers.
The document provides information about the Analog Servo Drive B40A20I. It can supply continuous current of 20A and peak current of 40A from a 40-190VDC power supply. It is designed to drive brushless DC motors and features adjustable current limits, input gain, and offset. It has protection against overheating, overcurrent, and short circuits.
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
The document provides information about the Analog Servo Drive B30A8. It can supply continuous current of 15A and peak current of 30A from a 20-80VDC power supply. It is designed to drive brushless DC motors and features adjustable current limits, four quadrant regenerative operation, and protection against overheating and short circuits. It can interface with digital controllers or operate stand-alone and has modes for current control, duty cycle control, hall velocity control and velocity control.
The Analog Servo Drive B25A20I is designed to drive brushless DC motors with a peak current of 25A and continuous current of 12.5A. It can interface with digital controllers or operate stand-alone using a single unregulated DC power supply between 40-190VDC. The drive features adjustable current limits, input gain, and offset using potentiometers as well as selectable operating modes and commutation phasing using DIP switches. It is compliant with various safety and EMC standards including UL, CE, and RoHS.
The document describes the Analog Servo Drive B25A20AC. It is designed to drive brushless DC motors with a peak current of 25A and continuous current of 12.5A. It can operate on a single 30-125VAC power supply and has protection against overvoltage, overcurrent, and other faults. It provides adjustable current limits and loop gains using on-board potentiometers and can interface with digital controllers or operate standalone.
The document describes an analog servo drive called the BE25A20I. It has the following key specifications:
- It can provide up to 25A of peak current and 12.5A of continuous current.
- It is designed to drive brushless DC motors and can operate in various modes like current, duty cycle, and velocity modes.
- It has protections against overheating, overvoltage, undervoltage, and short circuits.
- It can interface with encoders, Hall sensors, or tachometers for motor feedback and supports motors with three phases.
The document describes an analog servo drive called the BE40A20I. It has the following key specifications:
- It can provide a peak current of 40A and continuous current of 20A from a 40-190VDC power supply.
- It is designed to drive brushless DC motors and supports various feedback types including halls sensors and encoders.
- It has protection against overvoltage, undervoltage, overcurrent and other faults. It also has adjustable parameters like current limits and gains.
The document describes an analog servo drive that can drive brush DC motors. It provides peak currents of 30A and continuous currents of 15A. It operates from a 30-125VAC supply and has adjustable current limits, input gain, and offset. It supports feedback from tachometers and position sensors and can operate in different modes like current and velocity control. It has protections against overcurrent, overvoltage, and short circuits.
The document provides information about Amtech's Axpert-Hivert medium voltage drive product line. It includes sections on product structure, working principles, control system, applications, and technical parameters. The drive uses IGBT power cells connected in series for medium voltage input/output and employs space vector PWM control. It has a user-friendly touchscreen interface and can be used to control fans, pumps, compressors and other medium voltage AC motors.
The Analog Servo Drive B30A8I is designed to drive brushless DC motors with a peak current of 30A and continuous current of 15A. It can interface with digital controllers or operate stand-alone using a single unregulated DC power supply between 20-80VDC. Key features include adjustable current limits, gain, and offset settings using potentiometers to tune performance.
This document provides information on the M/VTM Series Servo Drive AB125A200. It is a brushless DC motor amplifier that can deliver up to 125A of peak current and 80A of continuous current. It has various operating modes including current, velocity, and duty cycle. It supports feedback from Hall sensors, encoders, and tachometers. Hardware settings like switches and potentiometers allow adjusting parameters like current limits and loop gains.
Similar to Kikusui dc electronic_load_plz-5wh2 denkei (20)
Multi-channel low noise arbitrary waveform generation system
Multi-channel precision low noise DC voltage source
Multi-channel low noise amplification system
The document discusses the benefits of exercise for mental health. Regular physical activity can help reduce anxiety and depression and improve mood and cognitive functioning. Exercise causes chemical changes in the brain that may help protect against mental illness and improve symptoms.
Ono sokki ds3000 Data Station DS-3000 series Sound and Vibration Real-time...NIHON DENKEI SINGAPORE
1. The DS-3000 Series can perform real-time analysis of noise and vibration generated from various industrial products. It features high-speed processing hardware and easy-to-use software.
2. Real-time octave analysis breaks sounds down into frequency bands similar to human hearing, allowing analysis of noise levels over time. FFT analysis separates waveforms into frequency components.
3. Tracking analysis is useful for analyzing rotational machines like engines. It detects resonance between rotational speed and natural frequencies that could cause problems.
This document provides information on various data loggers including the LR8450, LR8450-01, LR8410-20, LR8431-20, and 8423. It compares their key specifications such as number of channels, maximum sampling interval, input types, and wireless communication capabilities. Application examples are also provided for combining the data loggers with other Hioki instruments to measure values like temperature, resistance, current, voltage, power, and strain.
The document discusses Hioki's lineup of current sensors and current probes for various current measurement applications. It provides details on their specifications and suitability for different use cases, such as evaluating power devices, automotive systems, power quality maintenance, power consumption assessment, and more. The sensors and probes are optimized for measuring currents ranging from miniscule to large magnitudes, operating at frequencies from DC to the GHz range. Models are designed for high-accuracy measurement, waveform observation, and grid power quality control across industries including automotive, renewable energy, and electronics.
This document provides an overview of Hioki's field measuring instruments and their applications in various industrial settings. It introduces Hioki as a leader in test and measuring instruments, with integrated R&D and manufacturing allowing for sustainable product innovation. Various Hioki instruments are then mapped to common applications in factories, including measuring motor insulation, supply voltage, load current, grounding, temperature, and more. Similar mappings are provided for applications in data centers and PV systems.
The document provides an overview of various electrical measuring instruments and testing equipment offered by Hioki, including:
- Battery testers for measuring the internal resistance and open-circuit voltage of batteries used in applications like electric vehicles, power tools, smartphones, and more.
- Motor measurement solutions for performance analysis and quality testing, including power analyzers, clamp sensors, and data loggers.
- Equipment for designing, developing, and testing motors and inverters, such as power analyzers for evaluating efficiency, temperature sensors, and insulation testers.
- Production testing devices like winding testers, breakdown voltage testers, resistance meters, and LCR meters.
- Additional product categories like data loggers, safety test
The DIFFERENTIAL PROBE 9322 provides 3 measurement functions with a single probe: 1) floating measurement of high voltage waveforms up to 1000V AC/DC, 2) detection of surge noise on power supply lines, and 3) true RMS rectified output of high voltage AC. It can be powered by an AC adapter or Hioki’s Probe Power Unit and measures signals up to 2000V DC or 1000V AC with a 1/1000 output.
The document describes the features and capabilities of the Hioki PW8001 power analyzer. It can measure up to 8 power channels with the highest accuracy from DC to high frequencies. It accurately captures power fluctuations from high-speed switching converters. It also provides full compatibility with various current sensors and can automatically perform phase correction for accurate measurement of high-frequency, low power factor power.
This document provides information on various measurement solutions for the automotive industry, including:
1) Systems for measuring engine-related parameters like combustion chamber volume, analyzing engine noise and vibrations, and inspecting transmission components.
2) Solutions for testing vehicle bodies, including analyzing vibration modes and locating sound sources.
3) Methods for evaluating interior comfort, such as measuring sound absorption and performing psychoacoustic assessments.
4) A system for testing muffler acoustic performance.
The document also provides information on related products like multi-channel analyzers, sensors, and anechoic chambers.
Inspect solar panel bypass diodes for opens and shorts in broad daylight without covering panels
INSPECT SOLAR PANEL BYPASS DIODES FOR OPENS AND SHORTS IN BROAD DAYLIGHT WITHOUT COVERING PANELS
Traditionally, bypass diodes can only be inspected for good working condition at night or when power is not being generated by the solar panels in order to verify that any applied current is guided past the solar cells.
With the FT4310, you can detect for open faults even when the sun is out without covering the panels.
Testing can also be performed at night.
*Testing for short-circuit faults can only be performed during the day.
DP800 series includes single output, two output and three output programmable linear DC power supply. They have pure output, excellent performance indicators, multiple analysis functions, rich interfaces, and can meet the diverse testing needs.
This document lists specifications for 7 load cell models - the RZ-1 through RZ-100. Each model is designed to measure different maximum force ranges from 1kg to 100kg with varying minimum increments between 0.1g and 10g. The document also provides model numbers, maximum ratings, and force ranges for each load cell.
The TD-9000T is a digital indicator for load management that supports two inputs, load (load cell) and stroke (displacement gauge).
High-speed A/D conversion of 25,000 times/sec and equipped with a 4.3-inch touchscreen monitor in DIN1/4 (92 x 92) size. While being high-end, it is a high-performance model that realizes a low price.
Waveforms during measurement can be checked in real time. Widely usable from daily monitoring to verification of processing data.
Threats to mobile devices are more prevalent and increasing in scope and complexity. Users of mobile devices desire to take full advantage of the features
available on those devices, but many of the features provide convenience and capability but sacrifice security. This best practices guide outlines steps the users can take to better protect personal devices and information.
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...Neo4j
Leonard Jayamohan, Partner & Generative AI Lead, Deloitte
This keynote will reveal how Deloitte leverages Neo4j’s graph power for groundbreaking digital twin solutions, achieving a staggering 100x performance boost. Discover the essential role knowledge graphs play in successful generative AI implementations. Plus, get an exclusive look at an innovative Neo4j + Generative AI solution Deloitte is developing in-house.
Full-RAG: A modern architecture for hyper-personalizationZilliz
Mike Del Balso, CEO & Co-Founder at Tecton, presents "Full RAG," a novel approach to AI recommendation systems, aiming to push beyond the limitations of traditional models through a deep integration of contextual insights and real-time data, leveraging the Retrieval-Augmented Generation architecture. This talk will outline Full RAG's potential to significantly enhance personalization, address engineering challenges such as data management and model training, and introduce data enrichment with reranking as a key solution. Attendees will gain crucial insights into the importance of hyperpersonalization in AI, the capabilities of Full RAG for advanced personalization, and strategies for managing complex data integrations for deploying cutting-edge AI solutions.
Climate Impact of Software Testing at Nordic Testing DaysKari Kakkonen
My slides at Nordic Testing Days 6.6.2024
Climate impact / sustainability of software testing discussed on the talk. ICT and testing must carry their part of global responsibility to help with the climat warming. We can minimize the carbon footprint but we can also have a carbon handprint, a positive impact on the climate. Quality characteristics can be added with sustainability, and then measured continuously. Test environments can be used less, and in smaller scale and on demand. Test techniques can be used in optimizing or minimizing number of tests. Test automation can be used to speed up testing.
UiPath Test Automation using UiPath Test Suite series, part 6DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 6. In this session, we will cover Test Automation with generative AI and Open AI.
UiPath Test Automation with generative AI and Open AI webinar offers an in-depth exploration of leveraging cutting-edge technologies for test automation within the UiPath platform. Attendees will delve into the integration of generative AI, a test automation solution, with Open AI advanced natural language processing capabilities.
Throughout the session, participants will discover how this synergy empowers testers to automate repetitive tasks, enhance testing accuracy, and expedite the software testing life cycle. Topics covered include the seamless integration process, practical use cases, and the benefits of harnessing AI-driven automation for UiPath testing initiatives. By attending this webinar, testers, and automation professionals can gain valuable insights into harnessing the power of AI to optimize their test automation workflows within the UiPath ecosystem, ultimately driving efficiency and quality in software development processes.
What will you get from this session?
1. Insights into integrating generative AI.
2. Understanding how this integration enhances test automation within the UiPath platform
3. Practical demonstrations
4. Exploration of real-world use cases illustrating the benefits of AI-driven test automation for UiPath
Topics covered:
What is generative AI
Test Automation with generative AI and Open AI.
UiPath integration with generative AI
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
UiPath Test Automation using UiPath Test Suite series, part 5DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 5. In this session, we will cover CI/CD with devops.
Topics covered:
CI/CD with in UiPath
End-to-end overview of CI/CD pipeline with Azure devops
Speaker:
Lyndsey Byblow, Test Suite Sales Engineer @ UiPath, Inc.
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!SOFTTECHHUB
As the digital landscape continually evolves, operating systems play a critical role in shaping user experiences and productivity. The launch of Nitrux Linux 3.5.0 marks a significant milestone, offering a robust alternative to traditional systems such as Windows 11. This article delves into the essence of Nitrux Linux 3.5.0, exploring its unique features, advantages, and how it stands as a compelling choice for both casual users and tech enthusiasts.
Best 20 SEO Techniques To Improve Website Visibility In SERPPixlogix Infotech
Boost your website's visibility with proven SEO techniques! Our latest blog dives into essential strategies to enhance your online presence, increase traffic, and rank higher on search engines. From keyword optimization to quality content creation, learn how to make your site stand out in the crowded digital landscape. Discover actionable tips and expert insights to elevate your SEO game.
Let's Integrate MuleSoft RPA, COMPOSER, APM with AWS IDP along with Slackshyamraj55
Discover the seamless integration of RPA (Robotic Process Automation), COMPOSER, and APM with AWS IDP enhanced with Slack notifications. Explore how these technologies converge to streamline workflows, optimize performance, and ensure secure access, all while leveraging the power of AWS IDP and real-time communication via Slack notifications.
GraphSummit Singapore | The Art of the Possible with Graph - Q2 2024Neo4j
Neha Bajwa, Vice President of Product Marketing, Neo4j
Join us as we explore breakthrough innovations enabled by interconnected data and AI. Discover firsthand how organizations use relationships in data to uncover contextual insights and solve our most pressing challenges – from optimizing supply chains, detecting fraud, and improving customer experiences to accelerating drug discoveries.
Cosa hanno in comune un mattoncino Lego e la backdoor XZ?Speck&Tech
ABSTRACT: A prima vista, un mattoncino Lego e la backdoor XZ potrebbero avere in comune il fatto di essere entrambi blocchi di costruzione, o dipendenze di progetti creativi e software. La realtà è che un mattoncino Lego e il caso della backdoor XZ hanno molto di più di tutto ciò in comune.
Partecipate alla presentazione per immergervi in una storia di interoperabilità, standard e formati aperti, per poi discutere del ruolo importante che i contributori hanno in una comunità open source sostenibile.
BIO: Sostenitrice del software libero e dei formati standard e aperti. È stata un membro attivo dei progetti Fedora e openSUSE e ha co-fondato l'Associazione LibreItalia dove è stata coinvolta in diversi eventi, migrazioni e formazione relativi a LibreOffice. In precedenza ha lavorato a migrazioni e corsi di formazione su LibreOffice per diverse amministrazioni pubbliche e privati. Da gennaio 2020 lavora in SUSE come Software Release Engineer per Uyuni e SUSE Manager e quando non segue la sua passione per i computer e per Geeko coltiva la sua curiosità per l'astronomia (da cui deriva il suo nickname deneb_alpha).
Building Production Ready Search Pipelines with Spark and MilvusZilliz
Spark is the widely used ETL tool for processing, indexing and ingesting data to serving stack for search. Milvus is the production-ready open-source vector database. In this talk we will show how to use Spark to process unstructured data to extract vector representations, and push the vectors to Milvus vector database for search serving.
Essentials of Automations: The Art of Triggers and Actions in FMESafe Software
In this second installment of our Essentials of Automations webinar series, we’ll explore the landscape of triggers and actions, guiding you through the nuances of authoring and adapting workspaces for seamless automations. Gain an understanding of the full spectrum of triggers and actions available in FME, empowering you to enhance your workspaces for efficient automation.
We’ll kick things off by showcasing the most commonly used event-based triggers, introducing you to various automation workflows like manual triggers, schedules, directory watchers, and more. Plus, see how these elements play out in real scenarios.
Whether you’re tweaking your current setup or building from the ground up, this session will arm you with the tools and insights needed to transform your FME usage into a powerhouse of productivity. Join us to discover effective strategies that simplify complex processes, enhancing your productivity and transforming your data management practices with FME. Let’s turn complexity into clarity and make your workspaces work wonders!
Unlocking Productivity: Leveraging the Potential of Copilot in Microsoft 365, a presentation by Christoforos Vlachos, Senior Solutions Manager – Modern Workplace, Uni Systems
Removing Uninteresting Bytes in Software FuzzingAftab Hussain
Imagine a world where software fuzzing, the process of mutating bytes in test seeds to uncover hidden and erroneous program behaviors, becomes faster and more effective. A lot depends on the initial seeds, which can significantly dictate the trajectory of a fuzzing campaign, particularly in terms of how long it takes to uncover interesting behaviour in your code. We introduce DIAR, a technique designed to speedup fuzzing campaigns by pinpointing and eliminating those uninteresting bytes in the seeds. Picture this: instead of wasting valuable resources on meaningless mutations in large, bloated seeds, DIAR removes the unnecessary bytes, streamlining the entire process.
In this work, we equipped AFL, a popular fuzzer, with DIAR and examined two critical Linux libraries -- Libxml's xmllint, a tool for parsing xml documents, and Binutil's readelf, an essential debugging and security analysis command-line tool used to display detailed information about ELF (Executable and Linkable Format). Our preliminary results show that AFL+DIAR does not only discover new paths more quickly but also achieves higher coverage overall. This work thus showcases how starting with lean and optimized seeds can lead to faster, more comprehensive fuzzing campaigns -- and DIAR helps you find such seeds.
- These are slides of the talk given at IEEE International Conference on Software Testing Verification and Validation Workshop, ICSTW 2022.
1. P L Z - 5 W H 2 S E R I E S
Compact High Voltage DC Electronic Load
D C E L E C T R O N I C L O A D
Operating voltage: 10 V to 1000 V (Min. 1.5 V)
Power capacity: 1 kW/2 kW/4 kW/12 kW/20 kW, 5 models
100 kW/ 2000 A with parallel operation (Max. 5 units) Connectable with 5WH series
LAN (LXI)/USB/RS232C standard digital interface *GPIB optional
Synchronized operation
Sequence function
Arbitrary IV characteristic (ARB) mode
Data-logging: voltage/current/power measurements
(Measurement display, programmable internal memory)
PLZ-5WH2 Series
NEW
Electronic Load
100kW
Up to
Max Power
*5 Unit Parallel
2. 2
High Power
Density
*Not including
protrusions
550
(21.65")
430
(16.93")
Unit: mm
13U
573.5 mm
(22.58")
Ideal for high capacity power supply and
rechargeable battery evaluation!
Testing with hyper-realistic load
simulation made possible!
The PLZ-5WH2 high power DC electronic
load series is where durable, reliable
ingenuity meets multifunctional and high
power design. Providing 5 variety of power
range line-ups, from 1 kW bench top style
model to high power model that can sink up
to 20 kW of power in a single unit. Possible
to easily selects applicable power range
depends on the load. Load simulation can
be achieved faster than ever before thanks
to the reliable, high speed design of the
PLZ-5WH current control circuits. Accurate
current measures can be made with
extremely high setting resolution. A color
LCD display allows for highly visible, user-
friendly front panel operation. RS232C,
USB, and LAN digital interfaces are
included as standard for simple integration
into any system.
● Operating voltage: 10 V to 1000 V (Min. 1.5 V)
● 20 kW capacity in a single, compact unit (PLZ20005WH2)
● Parallel operation: 5 units (Max. 100 kW/ 2000 A), Connectable with different models.*
*Connectable with 5WH series. However, a firmware update is required.
● Synchronization: Load on/off control and sequence execution can be synchronized among
multiple units.
● Sequence Function: Program can be saved / loaded on USB memory
● Arbitrary IV characteristic (ARB) mode
● User-friendly color LCD display
● Data logging function: voltage/current/power/elapsed time/integrated current/
integrated power measurements. (Measurement display, programmable internal memory,
stored as CSV format onto a USB.)
● Superposition of sinusoidal current (Sine Function, 1 Hz to 10 kHz)
● Cutoff function: The load can be turned off when the elapsed time, the voltage drop,
the integrated current, or the integrated power reaches the specified value.
● LAN (LXI)/USB/RS232C standard digital interface *GPIB optional
12 kW
PLZ12005WH2
20 kW
PLZ20005WH2
1 kW
PLZ1005WH2
2 kW
PLZ2005WH2
4 kW
PLZ4005WH2
NEW
Maximum Operating Voltage
1000V
Compact, High Power
Model Max operating current Operating voltage Power
PLZ1005WH2 20 A
10 V to 1000 V
1 kW
PLZ2005WH2 40 A 2 kW
PLZ4005WH2 80 A 4 kW
PLZ12005WH2 240 A 12 kW
PLZ20005WH2 400 A 20 kW
3U
128 mm
(5.04")
9U
396.2 mm
(15.60")
100kW
Up to
Max Power
*5 Unit Parallel
Compact High Voltage DC Electronic Load
PLZ-5WH2 Series
3. 3
100
10
approx.
1.5
1000
0
1 400
100
Input
voltage
[V]
Input current [A]
1000
Actual operating area
Operating area where
specifications are
guaranteed
20000 W
Logarithmic axis
1
50 V 400 A
1000 V 20 A
● Maximum current and power during parallel operation using the same model
Model
Parallel operation
number
Maximum current Maximum power
PLZ20005WH2
2 800 A 40 kW
3 1200 A 60 kW
4 1600 A 80 kW
5 2000 A 100 kW
Communication Interface
LAN, USB and RS232C standard digital interface. *GPIB Option
LXI compliant!!
Control and monitor the power
from buit-in browser!
Use a browser from a PC, smartphone, or tablet
to access the web server built into the PLZ-5WH2
series for convenient control and monitoring.
[Recommended browser]
●Microsoft Edge 10
●Internet Explorer version 9.0 or later
●Firefox 8.0 or later
●Safari/Mobile Safari 5.1 or later
●Chrome 15.0 or later
●Opera 11.0 or later
*Connecting with a smartphone, tablet, etc. requires a
Wi-Fi environment. (wireless LAN router etc.).
The PLZ-5WH2 series boasts a 20 μs rise time*, easily satisfying
the critical needs of power supply evaluation tests demanding a fast
transient response. *When using the PLZ20005WH2
PLZ20005WH2 Slew Rate: 20 A/μs
Current
(100
A/DIV)
Time (20 μs/DIV)
400 A
300 A
200 A
100 A
Current setting
Rated current
Operating voltage ranges from 10 V to 1000 V.
Minimum operating voltage required to sink current is 1.5 V.
[Operating area of PLZ20005WH2]
Operating
voltage ranges
10V to 1000V
Minimum
operating voltage
1.5V
Up to 100 kW with parallel operation (Max. 5 units)
Parallel Operation
Parallel operation (max. 5 units) is available on all models by simply
connecting an optional parallel operation cable. This feature is available
even among different models for a wide range of high power.
(up to 100 kW / 2000 A)
PLZ20005WH2 (5 units)
PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Different model
can parallel!
*A parallel cable needs to have each unit connection. 12 kW and 20 kW
models are included in accessory. 1 kW, 2 kW and 4 kW models are option.
In ARB mode, arbitrary I-V characteristics can be set by registering
multiple I-V characteristic points (pairs of voltage and current values).
Three up to 100 points can be registered, and the space between two
points is linearly interpolated. The minimum voltage (0.00 V) and current
(0.00 A) and the maximum voltage (1010.00 V) are fixed.
Arbitrary I-V Characteristics
(ARB) Mode
Example of setting value (* Value is fixed)
Voltage[V] Current[A]
0.00*
12.00
20.50
23.00
24.50
1010.00*
0.00*
0.10
0.20
0.40
0.80
0.80
10.00 20.00 30.00 1010.00
0.20
0.40
0.60
0.80
0
0
[A]
[V]
I-V characteristics example
Maximum Slew Rate of 20 A/μs
Wide Ranging Operation Voltage up to 1000 V
Parallel operation connection cable
Master unit
Slave unit Slave unit
Slave unit
Slave unit
PARALLEL
OUT IN
PARALLEL
OUT IN
PARALLEL
OUT IN
PARALLEL
OUT IN
PARALLEL
OUT IN
●Connection conceptual diagram
39 kW
100 kW
PLZ-5WH2 series
Smart
High Power
&
[Specifications: See P.10]
[Specifications: See P.12]
20 kW
12 kW
4 kW
2 kW
1 kW
×5
20 kW
[Specifications: See P.9]
Functions
● Parallel connection with PLZ-5WH series*
Must be PLZ-5WH as a Master and update the firmware to newest version.
*When parallel operation between 5WH and 5WH2, only same capacity
model is available.
Operation Modes
Constant current
(CC) mode
When a current value is specified, the current is kept at that
value even when the voltage changes.
Constant resistance
(CR) mode
Whenaconductancevalueisspecified,theproductsinkscurrentproportio-
naltothevoltagevariationbyusingthevalueasaproportionalityconstant.
Constant voltage
(CV) mode
When a voltage value is specified, the product runs the current
so that the voltage is kept at that value.
Constant power
(CP) mode
When a power value is specified, the product runs the current
so that the power is kept at that value.
Arbitrary I-V charac-
teristics (ARB) mode
The desired load characteristics can be set by specifying multiple
arbitrary voltage values and current values as I-V characteristics.
The following five operation modes are available on the PLZ-5WH2.
In addition, available to set in operation modes other than CV mode, the
“UVPL*” setting keep the voltage less than UVP setting by controlling
the current and the “UVPT” setting loads off by applying a current to
reach the target setting voltage.
[Specifications: See P.8-9]
*"UVPL" is the "+CV mode" in PLZ-5W series
4. 4
Functions
Load On/Off
The following load on/off settings are available in addition to standard
operations that can be carefully adjusted to fit the needs of any test
environment.
● Start with "load on" when power is turned on
● Display elapsed "load on" time
● Auto "load off" when time limit is reached
● Control "load on/off" with external controls such as relays
● "Load off" by specifying conditions (Cutoff function)
Soft Start
Soft start is a function that controls the rise time of the load current.
Soft start functions only when all the following conditions are met.
● The rise time of the soft start has been set.
● Load on state in constant current (CC) mode.
● There is an input that is equal to or exceeds the minimum operating
condition, from the state where there is no input to the load input
terminals.
If the load current rises sharply, the DUT output may become unstable
or the DUT’s overcurrent protection circuit may be activated. In such
situations, it is possible to make the load current to rise slowly only
when the product is started.
time
0
PLZ-5WH2 series
DUT’s voltage waveform
time
0
■ When soft start has been disabled ■ When soft start has been set properly
Load
On
Load
On
PLZ-5WH2 series
Rise start (Current starts flowing.)
PLZ-5WH2 series
Rise start (Current starts flowing.)
Input
voltage
or
current
Input
voltage
or
current
Operation mode CC
Time setting range
500 μs, 1 ms, 2 ms, 5 ms, 10 ms, 20 ms, 50 ms,
100 ms, or off
Changing the Response Speed
Set the response speed for CV, CR, or ARB mode according to the
DUT’s conditions and application.
Item Description
Response
Voltage Set the response speed for CV mode. Normal, Fast
Conductance Set the response speed for CR mode. Normal, Fast
ARB
Set the response speed for ARB mode. The value is the
filter response time. Select OFF for no filter.
OFF, 500 μs, 1 ms, 2 ms, 5 ms, 10 ms, 20 ms, 50 ms,
100 ms
Saving Measurement Data
Measurement data can be stored in CSV format to a USB memory
device.
Cutoff Function
The cutoff function allows the user to enable load off once the elapsed
time/voltage drop/integrated current/integrated power has been reached
after load on. Multiple factors can be selected, with load off being
implemented after the first requirement is met.
Elapsed time
The load turns off when the elapsed time value reaches the
specified value.
Voltage drop*
The load turns off when the voltmeter value reaches the
specified value.
Integrated current
The load turns off when the ampere-hour meter value reaches
the specified value.
Integrated power
The load turns off when the watt-hour meter value reaches the
specified value.
[Specifications: See P.11]
Integrated Data Function
Time elapsed, integrated current and integrated power can be logged.
Logging (integration) can be coordinated to start/finish when the load
turns on/off or during the start or end of a sequence. Logging can also
be controlled arbitrarily.
item Value Description
Integral Gate
- Set the integrated data recording period.
None Integrated data recording is started/stopped manually.
Load On
Recording is started/stopped automatically in synchronization
with load on/load off. Or, recording is started or stopped
manually.
Program Run
Recording is started/stopped automatically in synchronization
with sequence execution start/stop.
Or, recording is started or stopped manually.
Reset
-
Selects the integrated data reset method. If the product is
restarted, inte-grated data is reset.
Manual Integrated data is reset when the Reset key is pressed.
Auto Integrated data is automatically reset before the start of
recordings. Or, integrated data is reset when the Reset key is
pressed.
Time
Voltage
0
UVP
detection
voltage
Integrated data recording
Example:
Integral Gate is set to
Load On, and UVP is set
[Specifications: See P.11]
Data Logging Function
The data logging function allows
the user to log measurement
values (current, voltage, power) in
the internal memory, and display
logged data on an LCD screen
(Table) as a chart (Chart).
By setting measurement recording
conditions, you can control the
timing that measurements are
recorded.
Condition Value Description
Trigger −
Set the measurement recording timing and the
number of times to record measurements.
Source
−
Event (trigger source) that defines the measurement
recording condition. Recording starts after the
Initiate key is pressed and a trigger is received.
Immediate Pressing Initiate applies a trigger immediately.
BUS
Applies a trigger when a *TRG command is
received from a PC or when the *TRG key on the
front panel is pressed.
DIGITAL2*
Applies a trigger when a signal is received at pin
13 of the EXT CONT connector.
MSync
The trigger application timing is synced between
PLZ-5WH2 that are synchronized
TALink
Applies a trigger when a step is executed if
Generate is set to TALink in the sequence step
settings
Load Off Applies a trigger when the load is turned off.
Count 1 to 65536 The number of times to recorded measurements.
Delay
0 μs to 100 s
(resolution: 10 μs)
The delay time from trigger application until
measurement recording.
Interval Disable/Enable
Sets whether to insert an interval between
recordings when Count is 2 or higher.
Interval Time
10 μs to 3600 s
(resolution: 10 μs)
Recording interval time when Interval is set to
Enable.
Sense Aperture
10 μs to 1 s
(resolution: 10 μs)
Time period of each recording. The average over
the time period is recorded.
*Only when Direction of Digital 2 is set to Input
▲ Data logging display example (Figure display)
[Specifications: See P.9]
*Voltage drop cutoff operates in the same manner as UVPT of the UVP function.
UVP turns the load off based on the protection function, but the cutoff function
turns the load off when the specified conditions are met. As such, there is no need
to clear alarms, which is required when a UVPT is activated.
5. 5
Functions
Sine Function
The sine function varies the current sinusoidally. It is suitable for super-
posed ripple testing of large capacity power supplies and batteries.
When a sine operation is in progress, a trigger signal is output from the
TRIG OUT connector on the front panel. You can set this regardless of
whether the load is on or off. This function operates in CC mode.
You cannot set the slew rate. Set the sine amplitude with a value.
When a sine operation is in progress, a trigger signal is output for 10 μs
from the TRIG OUT connector on the front panel when the current passes
through the Set value on the rising edge (sine wave phase at 0 degrees).
0[A]
Amplitude [A]
Current [A]
Current
Time
Current: Load value (center
value of the amplitude)
Amplitude: Sine amplitud
0
Current
Time
TRIG OUT
10 µs
Current
Operation mode CC
Frequency setting range 1 Hz to 1 kHz, 2 kHz, 5 kHz, 10 kHz
Frequency
setting
resolution*
1 Hz to 10 Hz 1 Hz
20 Hz to 100 Hz 10 Hz
200 Hz to 1000 Hz 100 Hz
1000 Hz to 2 kHz, 5 kHz, 10 kHz
* (Reference) The resolution actually set in the device is period resolution ⊿ T= 20 μs,
as shown in the equation below. For example, if you specify 900 Hz, the period set in the
device will be n × ⊿ T = 56 × 20 μs = 1120 μs (where n is a number set in the device).
Converted to frequency, this becomes 1/1120 μs ≈ 893 Hz.
Sequence Function
A sequence consists of programs and steps. A program is a collection
of steps. Steps are executed in order one at a time, starting from
step 1. The completion of the last step signifies that the program has
been executed once. When the specified number of program loops is
completed, the sequence ends. You can set the load state (load on or
off, load value, slew rate) at the end of the sequence of a program.
Setting range Setting Description
By step
Load value
Current, conductance, voltage, power. The values that
can be set depend on the current operation mode.
Slew rate Sets the speed of change when the current is changed.
Step execution
time
0.000050 s to 3600000 s (50 μs to 1000 h),
resolution: 1 μs
Load on/off
control
To turn the load on, set the load setting transition
method to step or ramp.
Other Trigger signal setting, trigger signal output
For each
program
Number of loops
of program
1 to 100000 repetitions, or infinite repetitions.
Protection
function
Specifies the value at which a protection function
(OCP, OPP, UVP) is activated.
● TALink
The TALink (Transient Acquire Link) trigger makes it possible to log data in
PLZ-5WH2 in synchronization with the sequence steps. Logged data can
then be accessed through ommunication with the PLZ-5WH2 and saved to a
USB as a CSV file.
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9
Input
current
Time
Measurement
Loop 1 Loop 2
Set a program for each operation mode. Up to 30 programs can
be set.Up to 10000 steps total can be used in all programs.
Input current
Step 1 Step 2 Step 3 Step 4
Time
Program1
Load value
Step 1 Step 2 Step 3 Step 4
Program1
Pulse function refers to the operation of executing two settings repetitively.
It is suitable for transient response characteristics testing of large
capacity power supplies and batteries. When the pulse operation is in
progress, a trigger signal is output from the TRIG OUT connector on the
front panel. You can set this regardless of whether the load is on or off.
This function operates in CC and CR modes. The pulse amplitude is set
with a value or a percentage of the load value.
When the pulse operation is in progress, a trigger signal is output for
10 μs from the TRIG OUT connector on the front panel when the current
amplitude changes from low (Depth) to high (Set) level.
Pulse Function
Operation mode CC and CR
Frequency setting range 1.0 Hz to 10.0 kHz
Frequency
setting
resolution*
1 Hz to 10 Hz 0.1 Hz
11 Hz to 100 Hz 1 Hz
110 Hz to 1000 Hz 10 Hz
1.1 kHz to 10.0 kHz 0.1 kHz
* (Reference) The resolution actually set in the device is period resolution ⊿ T = 1 μs,
as shown in the equation below. For example, if you specify 9300 Hz, the period set in
the device will be n × ⊿ T = 108 × 1 μs = 108 μs (where n is a number set in the device).
Converted to frequency, this becomes 1/108 μs = 9259 Hz.
HIGH
LOW
0
Current
Time
TRIG OUT
10 µs
0[A][S]( 0 % )
Depth [A][S ][%]
Current [A] or
Conductance [S]
(100 %)
Current
Time
Current or conductance:
Load value in CC mode or CR mode
Depth: Pulse level
[Specifications: See P.9]
Trip Turns the load off. The setting display changes to UVPT.
Limit
Limits the voltage so as not to become equal to or less than the set value.
The setting display changes to UVPL.
●Alarm 2 (low urgency)
Name Mode Activation
Overcurrent protection (OCP) CR, CV, CP
Load off or limit
Overpower protection (OPP) CC, CR, CV, ARB
Undervoltage protection (UVP) CC, CR, CP, ARB
Load off, limit, or
activation off
Watchdog protection (WDP) All Load off
●Alarm 1 (high urgency)
Name Activation
Overvoltage detection (OVP)
Load off
Reverse-connection detection (Reverse)
Overheat detection, overcurrent detection of the front-panel
DC INPUT terminals (OTP/Front)
Alarm input detection (External)
Parallel operation anomaly detection
This function limits the current (UVPL) or turns off the load (UVPT) when the voltage
applied to the product becomes equal to or less than the UVP setting. You can set this
regardless of whether the load is on or off.
Alarm Function
This function detects anomalies and protects the DUT. There are two
types of alarm based on urgency level: alarm 1 (high urgency) and
alarm 2 (low urgency).
[Specifications: See P.10]
6. 6
ABC Preset Memories
Three setting values can be stored in preset memory slots A, B, and
C. All saved settings can be accessed at the press of a button, which
is perfect for when you want to quickly switch between three sets of
values.
The setup memory can store up to 20 sets (0 to 19) of the current
conditions of the items listed below. The current conditions can also be
saved in a USB memory device.
● Operation mode
● Load values (current, voltage, conductance, power)
● Slew rate
● Pulse amplitude (current/conductance or percentage)
● Pulse interval (frequency/time of one cycle and duty cycle/operating
time on the high side)
● Sine amplitude (current)
● Sine frequency
● Alarm operating conditions
● Content of ABC preset memories
A file saved on the PLZ-5WH2 can be transferred to the PLZ-5W via a
USB memory device. If the UVP is set to "limit" on the PLZ-5WH2, this
will be changed to +CV mode on the PLZ-5W (PLZ205W, PLZ405W,
PLZ1205W).
Setup Memory
Current and Voltage Monitor
In addition to the conventional current
monitor output, voltage monitor output
(0 V to 10 V/Output of 1/100 of measured
voltage) has been added to the front BNC
connector.
Synchronized Operation
The following synchronization features are available when simply
connecting the PLZ-5WH2 with other equipment using a communication
cable. Any of the models in the PLZ-5WH2 series can be connected
together. Synchronized operation is possible even during parallel
operation.
● Synchronizing load on/off among multiple pieces of equipment.
● Synchronizing measurements.
● Synchronizing the start time and resume time for sequences across
multiple units.
To EXT SYNC IN
of another device
EXT SYNC IN
EXT SYNC OUT
EXT SYNC OUT
LAN cable
[Connection example]
Remote Sensing
With remote sensing, the voltage measurement point can be changed
from the load input terminal to the DUT sensing point. By connecting
the sensing leads to the DUT, the effects of voltage drops caused by
resistance in the load cables can be reduced and the operation in CR /
CV / CP / ARB mode stabilized.
● Remote sensing input rated voltage: 1000 V
USB Keyboard
You can enter numbers/characters if you connect a keyboard to the
USB port on the front panel.
The types of keyboards that you can use are 101-key and 104-key
keyboards.
External Control
The PLZ-5WH2 can be controlled and monitored from an external
device. The external control terminals are isolated from the load input
terminal.
EXT CONT connector
pin number
14
25
1
13
Rear panel
[Specifications: See P.12]
[Specifications: See P.12]
Functions
Pin
no.
In/Out *1 Signal name Description
1 – STATUS COM Status signal common for pins 14 to 16.
2 NC – –
3 NC – –
4 NC – –
5 IN ALARM CLEAR Alarm clearing input
6 IN ALARM INPUT Alarm input
7 NC – –
8 NC – –
9 IN TRIG INPUT
Trigger input. Resumes program execution if Wait(post) was
set to Trig IN in a sequence step and the program was paused.
10 – A COM This is connected to the chassis.
11 OUT DIGITAL 0 DIGITAL0 output. Sequence control possible.
12 OUT DIGITAL 1 DIGITAL1 output. Sequence control possible.
13 IN/OUT DIGITAL 2
DIGITAL2 I/O. Input/output switchable.
Sequence signal output or the trigger input of sequences and
measurement function.
14 OUT ALARM1
ALARM1 output. ON when overvoltage detection, reverse-con-
nection detection, overheat detection, alarm input detection,
or parallel operation anomaly detection is activated, and also
during external alarm input.
15 OUT ALARM2 ALARM2 output. ON during OCP, OPP, UVP, or WDP operation.
16 OUT LOAD ON STATUS Load-on status output. ON during load on.
17 NC – –
18 IN LOAD ON/OFF CONT Load on/off control input. Logic level switchable.
19 – A COM This is connected to the chassis.
20 IN EXT CONT ADD
External voltage control input.
Controls the load setting of CC mode by adding current.
21 IN EXT CONT MODE
External voltage control input.
Controls the load values of CC, CR, and CP modes.
22 IN EXT CONT CV
External voltage control input.
Controls the voltage of CV mode.
23 – A COM This is connected to the chassis.
24 OUT IMON Current monitor output.
25 NC – –
*1 1000 V reinforced insulation between each terminal and the DC INPUT terminal.
7. 7
LV124 Standard L-02 Life test - high-temperature endurance test (Durability - Heat) [Life test]
[Combination of AC power source and electronic load equipment]
*DUT must function completely before/during/after testing (n=6 units)
AC Power Supply DC Electronic Load
AC
230 V
DC
1000 V
EUT EUT
EUT EUT
EUT EUT
Onboard Charger
● EV Charger Aging Tests
● DC-DC Converter Evaluation
DC-DC converter performance tests vital for automotive electric components can easily be carried out by controlling the converter input (DC
power supply) and output (DC electronic load). The DC power supply and electronic load can be started up simultaneously for variation tests
and efficiency tests.
PCR-WE/WE2 Series PLZ-5WH2 Series
DC Electronic Load
PLZ-5WH2 Series
DC Power Supply
PAT Series
0-
V
Input voltage
DC500 V
1U Multi Range Programmable DC Power Supply
PWX Series
DC-DC
Converter
Battery simulated voltage
DC13.5 V
Operating voltage
DC10 V to 1000 V
● Battery Discharge Testing
Battery discharge test can be conducted and results saved without a PC. The acquired data can be saved in CSV format on USB memory.
I/V Curve (sequence)
Cut conditions: Time
Data display: chart
Sample: 1
Volmetric property (Constant current)
Cut conditions: Voltage or capacity (Ah)
Data display: table
Sample: 5
DC Electronic Load
PLZ-5WH2 Series
Battery
Application
8. 8
The used terminology is as follows:
• TYP: These are typical values that are representative of situations where the product
operates in an en vironment with an ambient temperature of 23 °C (73.4 °F).
These values do not guarantee the performance of this product.
• setting: Indicates a setting.
• reading: Indicates a readout value.• rating: Indicates a rated value.
• Open: Indicates equivalence to the state in which the DC INPUT terminals are opened.
Unless specified otherwise, the specifications are for the
following settings and conditions.
• The product is warmed up for at least 30 minutes.
• Rear-panel DC INPUT terminals are used.
Specifications
■Rating
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operating voltage (DC) 10 V to 1000 V
Power 1000 W 2000 W 4000 W 12000 W 20000 W
Current 20 A 40 A 80 A 240 A 400 A
DC INPUT terminal’s isolation
voltage
Positive pin: ±1000 V, Negative pin: ±900 V
Minimum
operating
voltage
At the rated current 10 V
When the current
begins to flow
1.5 V or less
■Constant current (CC) mode
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operating range 0 A to 20 A 0 A to 40 A 0 A to 80 A 0 A to 240 A 0 A to 400 A
Setting range 0.0000 A to 20.2000 A 0.000 A to 40.400 A 0.000 A to 80.800 A 0.00 A to 242.40 A 0.00 A to 404.00 A
Resolution 0.0005 A 0.001 A 0.002 A 0.005 A 0.01 A
Setting accuracy ±(0.2 % of setting + 0.1 % of rating)
Parallel operation ±(0.4 % of setting + 0.2 % of rating)
■Constant resistance (CR) mode
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operating range *1
H range 500 mS to 0 S 1 S to 0 S 2 S to 0 S 6 S to 0 S 10 S to 0 S
L range 5 mS to 0 S 10 mS to 0 S 20 mS to 0 S 60 mS to 0 S 100 mS to 0 S
Setting range
H range 505.00 mS to 0.00 S 1.01000 S to 0.00000 S 2.02000 S to 0.00000 S 6.0600 S to 0.00000 S 10.1000 S to 0.0000 S
L range 5.0500 mS to 0.0000 S 10.1000 mS to 0.0000 S 20.2000 mS to 0.000 S 60.600 mS to 0.000 S 101.000 mS to 0.000 S
Resolution
H range 0.01 mS 0.00002 S 0.00005 S 0.0002 S 0.0002 S
L range 0.0001 mS 0.0002 mS 0.0005 mS 0.002 mS 0.002 mS
Setting accuracy *2 H range ±(0.5 % of setting + 0.5 % of rating *3)
L range ±(0.5 % of setting + 0.2 % of rating *3)
Parallel
operation
H range ±(1.0 % of setting + 1.0 % of rating *3)
L range ±(1.0 % of setting + 0.4 % of rating *3)
Response speed NORM/FAST
*1. Conductance [S] = input current [A]/input voltage [V] = 1/resistance [Ω]
*2. Converted value at the input current. At the sensing point during remote sensing.
*3. Rated current
■Constant voltage (CV) mode
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operating range 10 V to 1000 V
Setting range 0.00 V to 1010.00 V
Resolution 0.02 V
Setting accuracy *1 ±(0.05 % of setting + 0.05 % of rating)
Parallel operation ±(0.1 % of setting + 0.1 % of rating)
Response speed NORM/FAST
*1. With the input voltage within the operating range, and at the sensing point during remote sensing.
■Constant power (CP) mode
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2
Operating range 0 W to 1000 W 0 W to 2000 W 0 W to 4000 W
Setting range 0.00 W to 1010.00 W 0.00 W to 2020.00 W 0 W to 4040.00 W
Resolution 0.02 W 0.05 W 0.1 W
Setting accuracy ±(0.5 % of rating *1 + 0.02 A × Vin *2) ±(0.5 % of rating *1 + 0.04 A × Vin *2) ±(0.5 % of rating *1 + 0.08 A × Vin *2)
Parallel operation ±(1 % of power rating + 0.1 % current rating × Vin *2)
Item PLZ12005WH2 PLZ20005WH2
Operating range 0 W to 12000 W 0 W to 20000 W
Setting range 0.0000 kW to 12.1200 kW 0.0000 kW to 20.2000 kW
Resolution 0.0005 kW
Setting accuracy ±(0.5 % of rating *1 + 0.2 A × Vin *2) ±(0.5 % of rating *1 + 0.4 A × Vin *2)
Parallel operation ±(1 % of power rating + 0.1 % current rating × Vin *2)
*1. Rated power
*2. DC INPUT terminal voltage or SENSING terminal voltage.
9. 9
Specifications
■Arbitrary I-V characteristics (ARB) mode
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operating range
Three to 100 points of current values can be specified for the input voltage.
Linear interpolation is applied between specified points.
Response speed 500 μs, 1 ms, 2 ms, 5 ms, 10 ms, 20 ms, 50 ms, 100 ms, or off
■Measurement function
Voltmeter
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Display 0.00 V to 1000.00 V
Resolution 10 mV
Accuracy ±(0.05 % of reading + 0.05 % of rating)
Parallel operation ±(0.1 % of reading + 0.1 % of rating) (TYP)
Ammeter
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Display 0.000 A to 20.000 A 0.000 A to 40.000 A 0.000 A to 80.000 A 0.00 A to 240.00 A 0.00 A to 400.00 A
Resolution 0.001 A 0.001 A 0.001 A 0.01 A 0.01 A
Accuracy ±(0.2 % of reading + 0.1 % of rating)
Parallel operation ±(0.4 % of reading + 0.2 % of rating) (TYP)
Power display
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Display Displays the product of the voltmeter reading and ammeter reading
Measurement trigger
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Trigger Source Immediate, BUS, DIGITAL2, MSync, TALink, LoadOff
Trigger Count 1 to 65536
Trigger Delay 0.00000 s to 100.00000 s
Interval Disable/Enable
Interval Time 0.00001 s to 3600 s
Sense Aperture 0.00001 s to 1.00000 s
■Pulse function
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operation mode CC and CR
Frequency setting range 1.0 Hz to 10.0 kHz
Frequency
setting
resolution *1
1 Hz to 10 Hz 0.1 Hz
11 Hz to 100 Hz 1 Hz
110 Hz to 1000 Hz 10 Hz
1.1 kHz to 10.0 kHz 0.1 kHz
Frequency
setting
accuracy
1 Hz to 5.0 kHz ±(0.5 % of setting)
5.1 Hz to 10.0 kHz ±(1.0 % of setting)
Duty cycle
setting range,
step
1 Hz to 10 Hz
5.0 % to 95.0 %, 0.1 % steps
11 Hz to 100 Hz
110 Hz to 1000 Hz
1.1 kHz to 10.0 kHz 5 % to 95 % *2, 1 % steps
*1. (Reference) The resolution actually set in the device is period resolution ⊿T = 1 μs, as shown in the equation below. For example, if you specify 9300 Hz, the period set
in the device will be n × ⊿T = 108 × 1 μs = 108 μs (where n is a number set in the device). Converted to frequency, this becomes 1/108 μs = 9259 Hz.
*2. The minimum time span is 20 μs. The minimum duty cycle is limited by the minimum time span.
Switch value (Depth)
Item *1 PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
CC mode 0.0000 A to 20.2000 A 0.000 A to 40.400 A 0.000 A to 80.800 A 0.000 A to 242.40 A 0.00 A to 404.00 A
CR mode
H range 505.00 mS to 0.00 S 1010.00 mS to 0.00 S 2020.00 mS to 0.00 S 6.06000 S to 0.00000 S 10.1000 S to 0.0000 S
L range 5.0500 mS to 0.0000 S 10.1000 mS to 0.0000 S 20.2000 mS to 0.0000 S 60.600 mS to 0.000 S 101.000 mS to 0.000 S
*1. The switch value is limited to the set current or set conductance or less.
10. 10
■Slew rate
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operation mode CC
Operating range 0.001 A/µs to 1 A/µs 0.002 A/µs to 2 A/µs 0.004 A/µs to 4 A/µs 0.01 A/µs to 12 A/µs 0.02 A/µs to 20 A/µs
Resolution 0.00002 A/µs 0.00005 A/µs 0.0001 A/µs 0.0002 A/µs 0.0005 A/µs
Setting accuracy *1 ±(10 % of setting +20 μs)
*1. Time to change from 10 % to 90 % when the current is changed from 0 % to 100 % of the rated current
■Sine function
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operation mode CC
Frequency setting range 1 Hz to 1000 Hz, 2000 Hz, 5000 Hz, 10000 Hz
Frequency
setting
resolution *1
1 Hz to 10 Hz 1 Hz
20 Hz to 100 Hz 10 Hz
200 Hz to 1000 Hz 100 Hz
1000 Hz to 2 kHz, 5 kHz, 10 kHz
Frequency
setting
accuracy
300 Hz to 900 Hz ±(1.0 % of setting)
Other than the
frequencies above
±(0.5 % of setting)
*1. (Reference) The resolution actually set in the device is period resolution ⊿T= 20 μs, as shown in the equation below. For example, if you specify 900 Hz, the period set in
the device will be n × ⊿T = 56 × 20 μs = 1120 μs (where n is a number set in the device). Converted to frequency, this becomes 1/1120 μs ≈ 893 Hz.
■Soft start
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operation mode CC
Time setting range 500 μs, 1 ms, 2 ms, 5 ms, 10 ms, 20 ms, 50 ms, 100 ms, or off
■Alarm function
Alarm 1
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Overvoltage detection Turns off the load when a voltage that is 110 % of the rating or higher is applied.
Reverse-connection detection Turns off the load when approximately -1 % of the rated current flows through the DC INPUT terminals.
Overheat detection, overcurrent
detection of the front-panel DC
INPUT terminals
Turns off the load when the heatsink temperature reaches 100 °C.
Or, turns off the load when a current of 30 A or higher is flowing through the front-panel DC INPUT terminals.
Alarm input detection Turns off the load when a voltage between 0 V and 1.5 V is applied to ALARM INPUT (pin 6) of the EXT CONT connector.
Parallel operation
anomaly detection
Turns off the load when any of the following errors occurs.
• An error occurred in the communication between the master unit and slave unit during parallel operation.
• A slave unit’s power supply was interrupted.
• A n overheating was detected on the master or slave unit.
• An overcurrent flowed through the front-panel DC INPUT terminals.
• PLZ-5WH series or PLZ-5W series was connected as a slave.
Alarm 2
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Overcurrent
protection
(OCP)
Setting range 0.000 A to 22.000 A 0.00 A to 44.00A 0.00 A to 88.00A 0.00 A to 264.00A 0.00 A to 440.00A
Resolution 0.001 A 0.01 A 0.01 A 0.01 A 0.1 A
Protection operation Select load off or limit.
Overpower
protection
(OPP)
Setting range 0.0 W to 1100.0 W 0.0 W to 2200.00 W 0 W to 4400 W 0.000 W to 13.200 kW 0.000 W to 22.000 kW
Resolution 0.1 W 0.1 W 1 W 0.001 kW 0.001 kW
Protection operation Select load off or limit.
Undervoltage
protection
(UVP)
Setting range 0.00 V to 1000.00 V, or off.
Resolution 0.02 V
Protection operation Select load off or limit.
Watchdog
protection
(WDP)
Setting range 1 s to 3600 s or off
Protection operation Load off
■Sequence function
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Operation mode CC, CR, CV, CP
Maximum number of programs 30
Maximum number of steps 10000
Step execution time 0.000050 s to 3600000 s (50 µs to 1000 h)
Time resolution 1 µs
Specifications
11. 11
■Integration display
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Elapsed time display Displays the time from load on to load off.
Range 0 s to 3600000 s (1000 h 0 min 0 s)
Ampere-hour meter display Displays integrated current
Range 0 Ah to 70000 Ah 0 Ah to 140000 Ah 0 Ah to 280000 Ah 0 Ah to 800000 Ah 0 Ah to 1400000 Ah
Watt-hour meter display Displays integrated power
Range 0 Wh to 40000000 Wh 0 Wh to 80000000 Wh 0 Wh to 160000000 Wh 0 Wh to 500000000 Wh 0 Wh to 800000000 Wh
■Cutoff function
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Elapsed time The load turns off when the elapsed time value reaches the specified value.
Range 0 s to 3600000 s (1000 h 0 min 0 s)
Resolution 1 s
Integrated current The load turns off when the ampere-hour meter value reaches the specified value.
Range 0 Ah to 70000 Ah 0 Ah to 140000 Ah 0 Ah to 280000 Ah 0 Ah to 800000 Ah 0 Ah to 1400000 Ah
Resolution
0.001 mAh (0.000 mAh to 1000.000 mAh)
0.001 Ah (1.001 Ah to 1000.000 Ah)
0.001 kAh (1.001 kAh to 1 000.000 kAh)
0.001 MAh (1.001 MAh to 1.400 MAh)
Integrated power The load turns off when the watt-hour meter value reaches the specified value.
Range 0 Wh to 40000000 Wh 0 Wh to 80000000 Wh 0 Wh to 160000000 Wh 0 Wh to 500000000 Wh 0 Wh to 800000000 Wh
Resolution
0.001 Wh (0.000 Wh to 1 000.000 Wh)
0.001 kWh (1.001 kWh to 1 000.000 kWh)
0.001 MWh (1.001 MWh to 800.000 MWh)
Voltage drop The load turns off when the voltmeter value becomes less than or equal to the specified value.
Range 0.00 V to 1000.00 V
Resolution 0.02 V
■Other functions
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Remote
sensing
Input voltage rating *1 1000 V *2
Isolation voltage ±1000 V
Number of units in parallel operation 5 units
Mutual synchronized operation *3
Synchronizes load on/off.
Synchronization of sequence execution, and sequence resumption.
Synchronizing the recording timing of measured values.
*1. There are limitations depending on the actual power that the load consumes.
*2. Total potential difference between the DC INPUT terminals and SENSING terminals
*3. The terminals for mutual synchronized operation are isolated from the DC INPUT terminals and operate at the chassis potential.
Specifications
12. 12
■EXT CONT connector
Item *1 PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Load on/off control input
Logic level switchable. Pulled up to 5 V by a 10 kΩ resistor.
The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V.
Alarm input
An alarm is activated with a voltage between 0 V and 1.5 V. Pulled up to 5 V by a 10 kΩ resistor.
The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V.
Alarm clearing input
After an alarm occurs, eliminate the root cause of the alarm, and change the input to pin 5 of the EXT CONT connector from a low
level signal to a high level signal. The alarm will be cleared on the rising edge of this signal.
Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5.0 V, LOW: 0 V to 1.5 V.
Trigger input
Paused sequence operation resumes when a voltage between 0 V and 0.66 V is received.
Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 2.31 V to 3.3 V, LOW: 0 V to 0.66 V.
External voltage control input(CC,
CR, CP mode)
Controls the load settings of CC, CR, CP mode through external voltage input.
Input impedance: Approx. 10 kΩ.
CC: The setting can be controlled in the range of 0 % to 100 % of the rated current through external voltage input of 0 V to 10 V.
CR: The setting can be controlled in the range of 0 % to 100 % of the conductance setting through external voltage input of 0 V to 10 V.
CP: The setting can be controlled in the range of 0 % to 100 % of the rated power through external voltage input of 0 V to 10 V.
Setting accuracy ±(1 % of rating) (TYP value in CC mode)
External voltage control input (CV
mode)
The load setting of CV mode can be controlled through external voltage input.
The rated voltage can be controlled in the range of 0 % to 100 % with 0 V to 10 V. Input impedance: Approx. 10 kΩ.
Setting accuracy ±(1 % of rating) (TYP)
External voltage control input
(superimposing in CC mode)
Controls the load setting of CC mode by adding current through external voltage input.
Adds current in the range of -100 % to 100 % of the rated current for -10 V to 10 V.Input impedance: Approx. 10 kΩ.
Setting accuracy ±(1 % of rating) (TYP)
Load-on status output On when load is on. Open-collector output from a photocoupler. *2
ALARM 1 output
ON when overvoltage detection, reverse-connection detection, overheat detection, front-panel DC INPUT overcurrent detection,
alarm input detection, or parallel operation anomaly detection is activated. Open-collector output from a photocoupler. *2
ALARM 2 output Turns on when OCP, OPP, UVP, or WDP is activated. Open-collector output from a photocoupler. *2
DIGITAL 0 output Can be controlled through sequences. Output impedance: Approx. 330 Ω.
The thresholds are HIGH: 2.5 V to 3.3 V, LOW: 0 V to 0.4 V.
DIGITAL 1 output
DIGITAL 2 input/output
Input/output switchable.
Output: Sequence trigger output. The output impedance is 330 Ω.The thresholds are HIGH: 2.5 V to 3.3 V, LOW: 0 V to 0.4 V.
Input: Trigger input signal for the sequence and the measurement functions. The thresholds are HIGH: 2.31 V to 3.3 V, LOW: 0 V to 0.66 V
Current monitor output Outputs 0 V to 10 V for 0 % to 100 % of the rated current. Output impedance: 1 kΩ (TYP).
Accuracy ±(1 % of rating) (TYP)
*1. 1000 V reinforced insulation between each terminal and the DC INPUT terminal
*2. The maximum voltage that can be applied to the photocoupler is 30 V. The maximum current is 4 mA.
■BNC connector
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Trigger output
Transmits 10 μs pulses during step execution when trigger output is set in a sequence.
Transmits 10 μs pulses during pulse operation and sine operation.
Output impedance: 200 Ω, output voltage HIGH: 4.2 V to 5.0 V, LOW: 0 V to 0.4 V.
Current
monitor
output
Output voltage Outputs 0 V to 10 V for 0 % to 100 % of the rated current
Output impedance 50 Ω (TYP)
Accuracy ±(1 % of rating)
Voltage
monitor
output
Output voltage Outputs the measured voltage with 1/100 magnification from 0 V to 10 V.
Output impedance 50 Ω (TYP)
Accuracy ±(1 % of rating)
Isolation voltage ±30 V
■Communication function
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
RS232C
Hardware
D-SUB 9-pin connector.
Baud rate: 9600, 19200, 38400, 115200 bps.
Data length: 8 bits, Stop bits: 1 bit, Parity bit: None
Flow control: No, CTS/RTS
Message terminator LF during reception, LF during transmission.
USB
(device)
Hardware
Standard type B socket.
Complies with the USB 2.0 specification. Data rate: 480 Mbps (High Speed).
Message terminator LF or EOM during reception, LF + EOM during transmission.
Device class Complies with the USBTMC-USB488 device class specifications.
USB
(host)
Hardware
Standard type A socket
Complies with the USB 2.0 specification. Data rate: 480 Mbps (High Speed).
LAN
Hardware
IEEE 802,3 100Base-TX/10Base-T Ethernet
IPv4, RJ-45 connector.
Compliant standards LXI 1.4 Core Specification 2011
Communication protocol VXI-11, HiSLIP, SCPI-RAW, SCPI-Telnet
Message terminator
VXI-11, HiSLIP: LF or END during reception, LF + END during transmission.
SCPI-RAW: LF during reception, LF during transmission.
Specifications
13. 13
■General specifications
Item PLZ1005WH2 PLZ2005WH2 PLZ4005WH2 PLZ12005WH2 PLZ20005WH2
Input voltage range 100 Vac to 240 Vac (90 Vac to 250 Vac) single phase
Input frequency range 47 Hz to 63 Hz
Power consumption 70 VAmax 90 VAmax 150 VAmax 360 VAmax 590 VAmax
Inrush current
(peak value)
100 Vac 30 Amax 30 Amax 30 Amax 40 Amax 40 Amax
230 Vac 80 Amax 80 Amax 80 Amax 160 Amax 160 Amax
Leakage current *1 0.5 mA or less 0.6 mA or less 0.8 mA or less 1.6 mA or less 2.4 mA or less
Environmental
conditions
Operating
temperature
range
0 °C to 40 °C (32 °F to 104 °F)
Operating
humidity range
20 %rh to 85 %rh (no condensation)
Storage
temperature
range
-25 °C to 60 °C (-13 °F to 140 °F)
Storage humidity
range
90 %rh or less (no condensation)
Installation
location
Indoor use, altitude of up to 2000 m, overvoltage category II
Insulation
resistance
Between primary
and chassis,
input, monitor
terminals
1000 Vdc, 30 MΩ or more (70 %rh or less)
Between input
terminals and
chassis, monitor
terminal
1000 Vdc, 3 MΩ or more (70 %rh or less)
Withstanding
voltage
Between primary
and chassis,
input, monitor
terminals
No abnormalities at 1500 Vac for 2 s
Between input
terminals and
chassis, monitor
terminal
No abnormalities at 1500 Vac for 2 s
External dimensions Refer to external dimensions
Weight Approx. 13 kg (28.7 lbs) Approx. 16 kg (35.3 lbs) Approx. 20 kg (44.1 lbs) Approx. 64 kg (141.1 lbs) Approx. 93 kg (205 lbs)
Accessories
[Common to all models]
Power cord (1 pc., length: 2.5 m), Safety terminal adapter TL41 (red 1 set, black 1set), External control connector kit (1 set),
Safety Information (1 copy), Setup Guide (1 copy), Quick Reference (Japanese 1 sheet, English 1 sheet), CD-ROM (1 disc)
[PLZ1005WH2, PLZ2005WH2, PLZ4005WH2]
Rear-panel DC INPUT terminal cover (1 set), Screw set for rear-panel DC INPUT terminals (2 sets),
Screws for the rear-panel DC INPUT terminal cover (2 pcs.) , Front-panel DC INPUT terminal cover (1 pc.),
Screws for the front-panel DC INPUT terminals (2 pcs.) , Heavy object warning label (1 pc.) PLZ4005WH2 only
[PLZ12005WH2, PLZ20005WH2]
Rear-panel DC INPUT terminals cover (1 set), Screw set for rear-panel DC INPUT terminals (2 sets),
Rear-panel DC INPUT terminals cover screws (2 pcs.),
Heavy object warning label (1 pc.), Parallel operation signal cable kit [PC02-PLZ-5W]
Electromagnetic
compatibility
(EMC) *2 *3
Complies with the requirements of the following directive and standards.
EMC Directive 2014/30/EU
EN 61326-1 (Class A *4), EN 55011 (Class A *4, Group 1 *5), EN 61000-3-2, EN 61000-3-3
Applicable under the following conditions
The maximum length of all cabling and wiring connected to the product must be less than 3 m.
Safety *2
Complies with the requirements of the following directive and standards.
EMC Directive 2014/35/EU *3
EN 61010-1 (Class I *6, Pollution Degree 2 *7)
*1. Leakage current between the positive and negative terminals of the rear-panel DC INPUT. At 1000 Vdc.
*2. Does not apply to specially ordered or modified products.
*3. Limited to models that have a CE mark on their panels.
*4. This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use
must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*5. This is a Group 1 instrument. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or
capacitive coupling, for the treatment of material or inspection/analysis purpose.
*6. This is a Class I instrument. Be sure to ground this product's protective conductor terminal.
The safety of this product is guaranteed only when the product is properly grounded.
*7. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity.
Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.
Specifications
16. GPIB Converter (PIA5100)
This converter converts RS232C or USB of the PLZ-5WH2 to GPIB,
enabling connection of a remote controller using GPIB.
[Accessories: Power cord set, Magnetic sheet]
[Connection example]
Parallel Operation Signal Cable Kit
One cable required for each slave/booster unit.
Rack Mount Bracket
These are rack mounting options.
Model Appropriate Model Description
KRB3-TOS PLZ1005WH2
PLZ2005WH2
PLZ4005WH2
For EIA inch racks
KRB150-TOS For JIS millimeter racks
KRB9
PLZ12005WH2
For EIA inch racks
KRB400-PCR-LE For JIS millimeter racks
KRB13
PLZ20005WH2
For EIA inch racks
KRB600 For JIS millimeter racks
PLZ5WH2
PIA5100
Remote control device
DC OUT (5 V)
RS232C or USB
GPIB
Name Model Cable length
Parallel operation cable
PC01-PLZ-5W Approx. 30 cm
PC02-PLZ-5W* Approx. 1 m
* Supplied with PLZ12005WH2 and PLZ20005WH2.
High-Voltage Load Cable Coming soon
This load cable supports high voltage.
Up to 80 A (Kikusui-recommended current) is supported.
Sequence Creation and Control Software NEW
The SD033-PLZ-5WH2(Wavy for PLZ-5WH2) is an application software
designed for sequence creation and operation of Kikusui’s PLZ-5WH2 series of
DC electronic loads. It allows users to freely carry out sequence control of power
supplies and electronic loads without any programming knowledge. Users can
easily edit sequences as if drawing a picture or working on a spreadsheet.
● Able to easily create and edit sequence functions using a mouse.
● Execution positions are visually displayed during sequence execution.
● Monitors voltage and current, which can be saved into files.
● Monitor data displayed in real time as a monitor graph.
Expand the ideas of engineers with the sequence creation and control software " Wavy "
SD033-PLZ-5WH2 (Wavy for PLZ-5WH2)
*Screen sample
Wavy
Series
Options
Printed in Japan Issue: Oct 2020 202010PDFEC11a
■ All products contained in this catalogue are equipment and devices that are premised on use under the
supervision of qualified personnel, and are not designed or produced for home-use or use by general
consumers. ■ Specifications, design and so forth are subject to change without prior notice to improve the
quality. ■ Product names and prices are subject to change and production may be discontinued when
necessary. ■ Product names, company names and brand names contained in this catalogue represent the
respective registered trade name or trade mark. ■ Colors, textures and so forth of photographs shown in this
catalogue may differ from actual products due to a limited fidelity in printing. ■ Although every effort has been
made to provide the information as accurate as possible for this catalogue, certain details have unavoidably
been omitted due to limitations in space. ■ If you find any misprints or errors in this catalogue, it would be
appreciated if you would inform us. ■ Please contact our distributors to confirm specifications, price,
accessories or anything that may be unclear when placing an order or concluding a purchasing agreement.
●Distributor:
www.kikusui.cn
Room 305,Shenggao Building , No.137,Xianxia Road, Shanghai City, China
Phone : 021-5887-9067 Facsimile : 021-5887-9069
www.kikusuiamerica.com
1-310-214-0000
3625 Del Amo Blvd, Suite 160, Torrance, CA 90503
Phone : 310-214-0000 Facsimile : 310-214-0014
Southwood 4F,6-1 Chigasaki-chuo,Tsuzuki-ku,Yokohama,224-0032,Japan
Phone: (+81)45-482-6353,Facsimile: (+81)45-482-6261,www.kikusui.co.jp
Trial version
available on
website!
http://www.kikusui.co.jp/
en/download/index.html
Download !
nihon denkei