Bộ lưu điện ups gtec chính hãng Italia được cung cấp và phân phối độc quyền tại Việt Nam bởi Công ty TNHH Kỹ Thuật VBS. Hiện nay Bộ lưu điện ups đang chiếm lĩnh thị trường nguồn điện dự phòng tại việt nam trong thời kỳ công nghệ 4.0.
https://ups-gtec.com/
NOVA is Ortech Power Solutions compact UPS range. Nova include superior technical performance and high reliabilty. Discover our UPS range.
With 0.9 output power factor, NOVA UPSs deliver 11 to 12% additiobal power compare to traditional 0.8 Output power factor systems.
Sentinel Dual is the best solution for powering mission critical applications and electro-medical devices requiring maximum power reliability.Sentinel Dual can be installed on the floor or in rack cabinets for networking applications.
NOVA is Ortech Power Solutions compact UPS range. Nova include superior technical performance and high reliabilty. Discover our UPS range.
With 0.9 output power factor, NOVA UPSs deliver 11 to 12% additiobal power compare to traditional 0.8 Output power factor systems.
Sentinel Dual is the best solution for powering mission critical applications and electro-medical devices requiring maximum power reliability.Sentinel Dual can be installed on the floor or in rack cabinets for networking applications.
Kikusui DC power supply high power capacity 4kW, 8kW
Up to 1500V output
Programmable
For Solar panel testing Electric vehicle battery testing
https://www.n-denkei.com/singapore/inquiry/
The UNO-2.0-I and UNO-2.5-I are the latest single phase string inverters in the line. A new-look inverter but packed with ABB’s proven high performing technology. The new look inverter has new features including a special built-in heat sink compartment and front panel display system.
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng catalog biến tần Frenic ACE Mới Nhất 2019 . Dòng biến tần chất lượng và kinh tế nhất của hãng Fuji Electric hiện nay, được sản xuất tại Thái Lan và dành riêng cho khu vực Đông Nam Á.
TMEIC MVG 2 Medium Voltage Drive up to 19,500 KVA at 11 kvDavid Batts
High Reliability, Energy Efficiency, Lower Harmonic Distortion, Local Sales ,Service, & Technical Support, 20 + year Capacitor life, bump less , make-before-break transfer
Catalog biến tần Frenic Lift - Fuji Electric mới nhất 2019CTY TNHH HẠO PHƯƠNG
Catalog biến tần Frenic Lift do hãng Fuji Electric Nhật bản phát hành, mô tả đầy đủ về dòng biến tần Frenic Lift gồm:
Thông số kỹ thuật cơ bản
Tính năng
Sơ đồ đấu nối, thông tin các chân điều khiển
Kích thước
Các hàm cài đặt
Biến tần Frenic-Lift với hệ số quá tải lên đến 200%/10s cùng với đó là tuổi thọ và độ bền lâu dài (tuổi thọ DC bus lên đến 10 năm). ACR: 500Hz, hơn 5 lần so với model trước ( so sán với dòng UD).
RAM Audio Catalogue - Premium Audio Power Amplifiersproaudioindia
Founded in 1982, CE Studio-2 is a Spanish Electronic Manufacturing Company know for innovation in Amplifier Technology. The complete range of RAM Audio Power Amplifiers are available in India with Harness Overseas Pvt. Ltd. Call us for a free demo - 0172-2236154. Write to us on info@harnessasia.com. Visit us our website www.harnessasia.com
Digital isolation plays a key role in designing industrial motor control systems. This presentation takes you through why, where and how for isolation designs that optimize system performance while meeting the ever stringent safety and efficient standards. Analog Devices, Nicola O'Byrne at PCIM 2015
Isolation in gate drive is one critical area for designing efficient, safe and highly productive motor control systems. Learn how the latest ADI isolated gate drives can help you solve the design challenges. Analog Devices, Dara O'Sullivan PCIM 2015
The Fortress Series Tower is a 3 phase, 208V, parallel capable, fully redundant, true online, double-conversion UPS features a small footprint cabinet, built in batteries, DSP control, programmable bat tery voltage.
Kikusui DC power supply high power capacity 4kW, 8kW
Up to 1500V output
Programmable
For Solar panel testing Electric vehicle battery testing
https://www.n-denkei.com/singapore/inquiry/
The UNO-2.0-I and UNO-2.5-I are the latest single phase string inverters in the line. A new-look inverter but packed with ABB’s proven high performing technology. The new look inverter has new features including a special built-in heat sink compartment and front panel display system.
Công ty Cổ phần Hạo Phương xin gửi đến quý khách hàng catalog biến tần Frenic ACE Mới Nhất 2019 . Dòng biến tần chất lượng và kinh tế nhất của hãng Fuji Electric hiện nay, được sản xuất tại Thái Lan và dành riêng cho khu vực Đông Nam Á.
TMEIC MVG 2 Medium Voltage Drive up to 19,500 KVA at 11 kvDavid Batts
High Reliability, Energy Efficiency, Lower Harmonic Distortion, Local Sales ,Service, & Technical Support, 20 + year Capacitor life, bump less , make-before-break transfer
Catalog biến tần Frenic Lift - Fuji Electric mới nhất 2019CTY TNHH HẠO PHƯƠNG
Catalog biến tần Frenic Lift do hãng Fuji Electric Nhật bản phát hành, mô tả đầy đủ về dòng biến tần Frenic Lift gồm:
Thông số kỹ thuật cơ bản
Tính năng
Sơ đồ đấu nối, thông tin các chân điều khiển
Kích thước
Các hàm cài đặt
Biến tần Frenic-Lift với hệ số quá tải lên đến 200%/10s cùng với đó là tuổi thọ và độ bền lâu dài (tuổi thọ DC bus lên đến 10 năm). ACR: 500Hz, hơn 5 lần so với model trước ( so sán với dòng UD).
RAM Audio Catalogue - Premium Audio Power Amplifiersproaudioindia
Founded in 1982, CE Studio-2 is a Spanish Electronic Manufacturing Company know for innovation in Amplifier Technology. The complete range of RAM Audio Power Amplifiers are available in India with Harness Overseas Pvt. Ltd. Call us for a free demo - 0172-2236154. Write to us on info@harnessasia.com. Visit us our website www.harnessasia.com
Digital isolation plays a key role in designing industrial motor control systems. This presentation takes you through why, where and how for isolation designs that optimize system performance while meeting the ever stringent safety and efficient standards. Analog Devices, Nicola O'Byrne at PCIM 2015
Isolation in gate drive is one critical area for designing efficient, safe and highly productive motor control systems. Learn how the latest ADI isolated gate drives can help you solve the design challenges. Analog Devices, Dara O'Sullivan PCIM 2015
The Fortress Series Tower is a 3 phase, 208V, parallel capable, fully redundant, true online, double-conversion UPS features a small footprint cabinet, built in batteries, DSP control, programmable bat tery voltage.
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
Catalog biến tần Frenic eHVAC - beeteco.com
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Địa chỉ : Số 7/31 KDC Thương Mại Sóng Thần, KP. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Tỉnh Bình Dương
FB: www.facebook.com/beeteco
Email: contact@beeteco.com
Tel: 0650 3617 012
Hotline: 0909.41.61.43
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...Amil Baba Dawood bangali
Contact with Dawood Bhai Just call on +92322-6382012 and we'll help you. We'll solve all your problems within 12 to 24 hours and with 101% guarantee and with astrology systematic. If you want to take any personal or professional advice then also you can call us on +92322-6382012 , ONLINE LOVE PROBLEM & Other all types of Daily Life Problem's.Then CALL or WHATSAPP us on +92322-6382012 and Get all these problems solutions here by Amil Baba DAWOOD BANGALI
#vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore#blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #blackmagicforlove #blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #Amilbabainuk #amilbabainspain #amilbabaindubai #Amilbabainnorway #amilbabainkrachi #amilbabainlahore #amilbabaingujranwalan #amilbabainislamabad
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
The Benefits and Techniques of Trenchless Pipe Repair.pdf
Bộ lưu điện ups gtec chính hãng Italia
1. online
UPS
ZP120i
• LOCAL AREA NETWORKS (LAN)
• SERVERS
• DATA CENTERS
• INTERNET CENTERS (ISP/ASP/POP)
• INDUSTRIAL PLCS
• EMERGENCY DEVICES (LIGHTS, ALARM)
• ELECTROMEDICAL DEVICES
• TELECOMMUNICATION DEVICES
• INDUSTRIAL APPLICATION
1, 2, 3, 6, 10, 15, 20 kVA
2. COMMON FEATURES:
G-TEC is proud to introduce the upgraded superior ZP120i UPS that can deliver clean, safe and regulated power
supply to protect your critical mission equipment, so as to safeguard your valuable equipment and critical data from
any abnormal power disturbances, such as surges, blackouts and lightning strikes. ZP120i UPS power capacity is
available from 1kVA to 20kVA 1/1 (1/1 stands for single phase input and single phase output); from 10kVA to
20kVA 3/1 (3/1 stands for three phase input and single phase output).
• Digital Signal Processor (DSP) Control
• Cold Start Function
• Strongest performance
• High Power Density
• Flexible Settings
• Internal components designed for stressing
environment
• Highest efficiency with low heat dissipation
• Long run time Model with optional battery and dedicated
super charger (KS Version)
ZP120i series
Strongest performance
• DSP technology fully controlled
• Self monitoring and fault diagnosis
• Lowest output voltage distortion
• Transient voltage surge suppressor (TVSS)
• Short circuit protection
1kVA to 3kVA 1/1
LCD Display
ON/OFF Button
Function Button
UPS
Status
Indicator
High Power Density
• Wide input voltage range
• 0.9 output power factor
• Input power factor connection and
lowest current distortion
Flexible Settings
• Selectable configuration via LCD:
online, eco-mode
• EPO connector for remote emergency power off
• External battery connection for KS model
• Simplified installation
ZP120i - 3K ZP120i - 1K
Intelligent Slot
Intelligent Slot
RS232 Port
RS232 Port
EPO
USB Port
USB Port
EPO
Network Surge Protection
Network Surge Protection
Output socket
Output socket
External Battery Socket for KS versionOutput Terminal Block
External Battery
Socket for KS version
Input Surge ProtectionInput Surge Protection
3. 6kVA to 20kVA 1/1
10kVA to 20kVA 3/1
Strongest performance
• DSP technology fully controlled
• LCD display multi language
• Real time event logs
• Dual internal communications bus
• Auto fan speed adjustment
• Short circuit protection
High Power Density
• 0,9 output power factor
• Minimum acceptable input voltage 110 Vac
Flexible Settings
• Selectable configuration via LCD: online, parallel,
eco-mode.
• Parallelable up to 3 units with optional parallel kit
• Standard mechanical maintenance bypass
• Optional internal insulation transformer
• EPO connector for remote emergency power off
• Standard external battery connection for KS model
• Back-feed protection
• External 16 or 20 blocks 12V battery model available
The 10-20kVA three phase input and single phase
output compact design has the same technical
performance with the following advantages:
• Input voltage 3 phase or 1 phase,easily chargable
• External battery 16 or 20 blocks 12V battery
available
ON/OFF Button
Return Button
Scroll
Button
Confirm
Button
UPS Status
Indicator
SNMP Slot
Ventilation Fan
Input MCB
External
Battery
Socket (KS)
Terminal
Block with
Cover
Dry Contact Slot
RS232 Port
EPO
USB
Parallel Port
Output MCB
Maintenance
Bypass MCB
ZP120i-6K-10K UPS
OPTIONAL
• External 8A charger PCB kit for 16 blocks 12V battery
• External 24A charger box for 16 blocks 12V battery
OPTIONAL
• External 8A charger PCB kit for 16 blocks 12V battery
• External 24A charger box for 16 blocks 12V battery
4. Communication and Power Management Solutions
With optional SNMP card, it has the function to remote monitor and control UPS, warning notifications through
broadcast and mobile phone, multi-shutdown PCs, and schedule UPS self-test. This unique software provides
complete power protection for computer system during power failure. The software supports lots of O/S including
Windows family, Linux, FreeBSD. More than that, to offer increased benefits for our customers, we have also
released USB version MAC version on the internet.
• Power flow display for monitoring UPS status
• Scheduled system shutdown/restart
• Scheduled UPS test
• Warning notification via E-mail / Pager
• Warning notification via Broadcast
• Password security protection
• Remote Monitor / Control via LAN
ZP120i 6kVA to 20kVA UPS with optional parallel kit fitted
in parallel configuration, can meet most demanding power
requirement. Increase power availability and flexibility.
Parallel Redundancy feature provides economic power solution
for system integration. Furthermore, parallel redundancy feature
equally shares the load to maximize UPS performance, and more
secure UPS continuous operation.
ETHERNETNETWORK
POWERSUPPLY
INPUT SWITCHBOARD
OUTPUT SWITCHBOARD
LOAD LOAD LOAD LOAD
5. TECHNICAL SPECIFICATIONS
Model ZP120i-1K ZP120i-1KS ZP120i-2K ZP120i-2KS ZP120i-3K ZP120i-3KS
Power Capacity
(* for 200VAc & 208Vac)
1kVA / 0.9kW @ 0.9PF
1kVA / 0.8kW @ 0.8PF (*)
2kVA / 1.8kW @ 0.9PF
2kVA / 1.6kW @ 0.8PF (*)
3kVA / 2.7kW @ 0.9PF
3kVA / 2.4kW @ 0.8PF (*)
INPUT
Voltage 200Vac / 208Vac / 220Vac / 230Vac / 240Vac
Acceptable voltage range
110Vac to 288Vac
>176Vac for 100% load / >154Vac for 80% load / >132Vac for 70% load / >110Vac for 50% load
Frequency Range 40Hz – 70Hz
Input PF >0.98
Power Factor ≥0.99 (I/P:220V, FULL RCD LOAD)
Input current 5.5A max 11A max 16A max
Input connection IEC C13 10A power cord IEC C19 16A power cord
BATTERY SECTION
Type Sealed lead acid maintenance free
DC voltage nominal 36Vdc - (3 x 12V7Ah) 72Vdc – (6 x 12V7Ah) 96Vdc – (8 x 12V7Ah)
Backup time (typical load) >8 -10mins External battery >9 - 11mins External battery >7 - 10 mins External battery
Recharge time 8 hours to 90%
UPS OUTPUT
Rated voltage 200Vac / 208Vac / 220Vac / 230Vac / 240Vac
Voltage stability ± 1 %
Rated Frequency 50Hz / 60Hz ±0.2% (free running mode)
Voltage distortion
≤2% linear load /
≤5.5% non-linear load
≤2% linear load / ≤5% non-linear load
Output waveform Pure Sinewave
Overload performance
Inverter mode: 105% ~ 130% for 1min and 150% for 30s, then transfer to bypass
Battery mode: 105% ~ 130% shutdown after 30s; 150% shutdown after 5s
Bypass mode: <130% continuous; >130% ~ <150% shutdown after 10mins; >150% ~ <180% shutdown after 5s
Crest factor 3 : 1
Output connection
4 x IEC320 C13 10A 4 x IEC320 C13 10A 4 x IEC320 C13 10A & Terminal Block
Other IEC, German, Australia sockets can be available upon request
General Characteristics
Transfer Time 0s bypass to Inverter / 2ms from Inverter to Bypass
Overall efficiency
94% ECO /
87% at 50% load, 86% at 100% load
97% ECO /
88% at 50% load, 87% at 100% load
97% ECO /
89% at 50% load, 87% at 100% load
Mimic panel information Large LCD display + command buttons + LED
Temperature 0°C to 40°C (operating) / -20°C to 70°C (storage)
Humidity <95% non condensing
Noise Level (@ 1m)
<43dBA at <60% load;
>60% load <47dBA
<45dBA at <60% load;
>60% load <50dBA
Net Size (mm) &
Net Weight (kg)
144(L) x 353(D) x 222(H) /
12 / 6 (KS)
190(L) x 374(D) x 336(H) /
21 / 10.5 (KS)
190(L) x 426(D) x 336(H) /
25.6 / 11.5 (KS)
Remote interfacing
USB port & Intelligent slot (standard);
Optional: SNMP Card; Dry contact card (DB9 or phoenix connector)
UPS management
USB port supports: Windows 2000/ 2003/ XP/ Vista/ 2008/ Windows 7
Power management from SNMP supports: TCP/IP; UDP; SNMP; Telnet; SNTP; PPP; HTTP; SMTP
Standard compliance
IEC 62040-1-1; IEC 62040-2 class A; IEC 61000-4-2 level 4;
IEC 61000-4-3 level 3; IEC 61000-4-4 level 4; IEC 61000-4-5 level 4; IEC 61000-2-2
ZP120i 1kVA to 3kVA
* ks version are provided with battery extra charger
** Derate to 90% with 208Vac output voltage. Derate to 80% with 200Vac output voltage, derate to 60% automatically when at converter mode
Note: product specifications are subject to change without further notice.
6. TECHNICAL SPECIFICATIONS
Model ZP120i-6K ZP120i-6KS ZP120i-10K-11 ZP120i-10KS-11 ZP120i-15KS-11 ZP120i-20KS-11
Power Capacity 6kVA/ 5.4kW 10kVA/ 9kW 15kVA/ 13.5kW 20kVA/ 18kW
UPS INPUT
Voltage 220Vac / 230Vac / 240Vac
Acceptable voltage range
110Vac to 288Vac
>110Vac for 65% load / >132Vac for 80% load / >154Vac for 90% load / >176Vac for 100% load
Frequency range 40Hz – 70Hz
Input PF ≥0.99
Input current 34A max 57A max 87A max 115A max
Input connection Terminal block
BATTERY SECTION
Type Sealed lead acid maintenance free
DC voltage nominal Default 192Vdc - (16 x 12V battery) / 240Vdc – (20 x 12V battery) on request
Backup time (typical load) >8 -10mins External battery >6 – 8mins External battery
Recharge time 7h to 90%
Depending on
Battery Ah
8h to 90% Depending on Battery Ah
UPS OUTPUT
Rated voltage 220Vac / 230Vac / 240Vac
Voltage stability ± 1 %
Rated frequency 50Hz / 60Hz ±0.5% (free running mode)
Voltage distortion ≤1% at linear load / ≤5% for non-linear load
Output waveform Pure sinewave
Overload performance
Inverter mode: 110% for 10mins; 130% for 1min;and 150% for 30s, then transfer to bypass
Battery mode: 110% shutdown after 10mins; 125% shutdown after 10s; >125% shutdown after 1s
Crest factor 3 : 1
Output connection Terminal block
General Characteristics
Transfer time
0s bypass to Inverter /
4ms from Inverter to Bypass
0 sec
Efficiency 98% ECO / 93% at 100% load 98% ECO / 93.5% at 100% load
Mimic Panel Information Large LCD display + command buttons + LED
Temperature 0°C to 40°C (operating) / -20°C to 70°C (storage)
Humidity <95% non condensing
Noise Level (@ 1m)
<48dBA at <70% load;
>70% load <58dBA
<48dBA at <70% load;
>70% load <60dBA
<53dBA at <70% load;
>70% load <66dBA
Size (mm) & Weight (kg) -
Standard
250(L) x 526(D) x 645(H), 57kg (6kVA); 65kg (10kVA) N.A.
Size (mm) & Weight (kg) -
KS Model
250(L) x 526(D) x 480(H), 18kg (6kVA); 20kg (10kVA) 250(L) x 544(D) x 705(H); 33kg
Remote interfacing
USB port & Intelligent slot (standard);
Optional: SNMP Card; Dry contact card (DB9 or phoenix connector)
UPS management
USB port supports: Windows 2000/ 2003/ XP/ Vista/ 2008/ Windows 7
Power management from SNMP supports: TCP/IP; UDP; SNMP; Telnet; SNTP; PPP; HTTP; SMTP
Standard compliance
IEC 62040-1-1; IEC 62040-2 class C3; IEC 61000-4-2 level 4;
IEC 61000-4-3 level 3; IEC 61000-4-4 level 4; IEC 61000-4-5 level 4; IEC 61000-2-2
ZP120i 6kVA to 10kVA
* ks version are provided with battery extra charger
** Derate to 90% with 208Vac output voltage, derate to 60% automatically when at converter mode
*** Optional external battery cabinet with or without battery is available upon request
Note: product specifications are subject to change without further notice.
7. ZP120i 10kVA to 20kVA
TECHNICAL SPECIFICATIONS
Model ZP120i-10K-31 ZP120i-10KS-31 ZP120i-15KS-31 ZP120i-20KS-31
Power Capacity 10kVA/ 9kW 15kVA/ 13.5kW 20kVA/ 18kW
UPS INPUT
Voltage 380Vac / 400Vac / 415Vac
Acceptable voltage range
(phase neutral)
110Vac to 288Vac
>110V~288V for 65% load / >132V~288V for 80% load / >154V~288V for 90% load / >176V~288V for 100% load
Frequency range 40Hz – 70Hz
Input PF ≥0.95
Input current @ 220V
(Rectifier / Bypass)
19A / 45A (max) 28.5A / 68A (max) 38A / 91A (max)
Input connection Terminal block
BATTERY SECTION
Type Sealed lead acid maintenance free type
DC voltage nominal Default 192Vdc - (16 x 12V battery) / 240Vdc – (20 x 12V battery) on request
Backup time (typical load) >6 – 8mins External battery
Recharge time 8h to 90% Depending on battery capacity
UPS OUTPUT
Rated voltage 220Vac / 230Vac / 240Vac
Voltage stability ± 1 %
Rated Frequency 50Hz / 60Hz ±0.5% (free running mode)
Voltage distortion ≤1% at linear load / ≤5% for non-linear load
Output waveform Pure sinewave
Overload performance
Inverter mode: 110% for 10mins; 130% for 1min;and 150% for 30s,
then transfer to bypass; shutdown after 1min
Battery mode: 110% shutdown after 10mins; 125% shutdown after 10s; >125% shutdown after 1s
Crest factor 3 : 1
Output connection Terminal block
General Characteristics
Transfer Time 0 secs
Efficiency 98% ECO / 91% at 100% load 98% ECO / 92% at 100% load
Mimic panel information Large LCD display + command buttons + LED
Temperature 0°C to 40°C (operating) / -20°C to 70°C (storage)
Humidity <95% non condensing
Noise Level (@ 1m)
<48dBA at <70% load;
>70% load <60dBA
<53dBA at <70% load;
>70% load <66dBA
Size (mm) (KS model) 250(L) x 562(D) x 770(H) 250(L) x 562(D) x 650(H) 250(L) x 562(D) x 710(H)
Weight 69kg 25kg 34kg 34kg
Remote interfacing
USB port & Intelligent slot (standard);
Optional: SNMP Card; Dry contact card (DB9 or phoenix connector)
UPS management
USB port supports: Windows 2000/ 2003/ XP/ Vista/ 2008/ Windows 7
Power management from SNMP supports: TCP/IP; UDP; SNMP; Telnet; SNTP; PPP; HTTP; SMTP
Standard compliance
IEC 62040-1-1; IEC 62040-2 class C3; IEC 61000-4-2 level 4; IEC 61000-4-3 level 3; IEC 61000-4-4 level 4;
IEC 61000-4-5 level 4; IEC 61000-2-2
* ks version are provided with battery extra charger
** Derate to 90% with 208Vac output voltage
*** Optional external battery cabinet with or without battery is available upon request
Note: product specifications are subject to change without further notice.
8. G-Tec Asia Pacific Pte Ltd
60 Kaki Bukit Place, #03-05, EunosTechpark II, Singapore 415979
Tel. +65 6555.5014 - Fax +65 6555.4105
info@gtec.com.sg
www.gtec-power.com