This document provides an overview of gravity flow water supply systems that are commonly used in rural, hilly areas of Nepal. It describes the key components of these systems including various types of intakes, collection chambers, reservoirs, pipelines, and tap stands. It also discusses the feasibility and design process, including assessing community need, conducting surveys, and applying hydraulic principles. Design considerations like avoiding U-profiles in pipelines and using break pressure tanks are also covered.
Types- selection of the suitable site for the diversion headwork components
of diversion headwork- Causes of failure of structure on pervious foundation- Khosla’s theory- Design of concrete sloping
glacis weir.
supplying wholesome water to consumers with suitable methods in economical way,to exist human life water is very important as air is,so,as a civil engineer's we have to supply safe water to consumers in economical way,in this we are going to explain about component parts of water supply scheme,systems of water distribution and layouts of distribution system according to their suitability.
Any hydraulic structure which supplies water to the off taking canal known as headwork. Storage head work is that stores water when it is available and supplies when needed.
Types- selection of the suitable site for the diversion headwork components
of diversion headwork- Causes of failure of structure on pervious foundation- Khosla’s theory- Design of concrete sloping
glacis weir.
supplying wholesome water to consumers with suitable methods in economical way,to exist human life water is very important as air is,so,as a civil engineer's we have to supply safe water to consumers in economical way,in this we are going to explain about component parts of water supply scheme,systems of water distribution and layouts of distribution system according to their suitability.
Any hydraulic structure which supplies water to the off taking canal known as headwork. Storage head work is that stores water when it is available and supplies when needed.
Water conservation by Rainwater Harvesting systems – Treatment of waste water : Physical,Chemical and
Biological methods – Root Zone treatment - Use of recycled water.
Use of Environment friendly materials, Embodied Energy of materials, Bio degradable materials. Recycling
and Reuse of steel, Aluminium and Glass.
Sewer appurtenances are those structures and devices of a sewerage system which are constructed at suitable intervals along a sewer line to assist in the efficient operation and maintenance of the system. Following are the important sewer appurtenances: 1. Inlets 2. Catch Basins or Catch Pits 3. Clean-Outs 4.
sewer appurtenances ppt
sewer appurtenances and their details
types of appurtenances
appurtenances definition construction
appurtenances in construction
sewerage appurtenance
pipeline appurtenances definition
building appurtenances
sewerage appurtenance
sewer appurtenances and their details
appurtenances in construction
building appurtenances
appurtenances definition construction
types of appurtenances
pipeline appurtenances definition
1. Chapter 9 Gravity flow water supply system
Introduction
Nepal consists of several rural villages. The rural villages of hilly area of Nepal are suffering from
hardship in drinking water. Several agencies are trying to make water available for drinking in such areas.
Gravity system of water supply is that system in which water flows under gravity without use of any
external energy to deliver water from source to tap stand. The gravity flow water supply system is most
appropriate for rural sloppy terrain of Nepal where the source is usually situated at the uphill and the
community is as far down.
In this system, water san be supplied to the community with or without using reservoirs. Technically this
is called closed or open systems. Open system is used when the design demand can meet by the safe yield
of the source. If safe yield cannot meet the demand we use closed system. The closed system can also be
continuous or intermittent type.
The component of gravity flow water supply systems are:
1. Intake: (Spring/ Stream/River/Infiltration Galleries)
2. Collection Chamber
3. Interruption chamber (IC) and Break pressure tank (BPT):
4. Distribution chamber (DC)
5. Reservoirs (RVT)
6. Air valve
7. Washouts
8. Sectional valve chambers
9. Valve chamber
10. Sedimentation tanks
11. Pipeline: (a) Transmission main (b) Distribution main
12. Pipe crossings: (a) Simple crossing (b) Suspended crossing
13. Tapstands
Feasibility and Detailed Surveying
Village Development Committee (VDC) carries out the need assessment of water supply for the
communities and it is submitted to District Development Committee (DDC). Screening of the project is
carried out by the DDC and they are proceed for feasibility study. It consists of the study of the technical,
economical and social aspect of the project. Viewing and analyzing the project objective, technical aspect,
tentative cost, funding source, resources, social and economical aspect the feasibility report is prepared
2. and submitted to DDC for approval. After approval by DDC, water users committee (WUC) is formed
and detail survey is carried out for technical, social and economical aspect for detailed design, preparation
of drawings and cost estimate.
Hydraulic Theory
All hydraulic theories are applicable for the system. The design is based on the hydraulic theories of open
channel flow as well as pipe or pressure flow. The following theories are applicable in gravity flow water
supply systems.
1. Continuity Equation
2. Bernoulli Equation
3. Principle of Headloss (major and minor)
4. Pressure theories
The design of pipes is based on head loss principle. The elevation and length of the pipe are very
important in the design. So, profile leveling is the main data used in the design of the system.
U-profiles
In the route of pipeline for gravity flow water supply, there may be several U-profiles in hilly terrains. In
this case, the valley side is liable for silting problem and hillside is for air clogging. In that case, washouts
in the valley side and air relief valve in the hillside should be provided. The valves are liable to be
maintained frequently, so it is preferred to avoid u-profiles as far as possible.
BPT
It is constructed to break the static pressure if pipeline exceeds its maximum pressure rating to protect
pipe from burst. This tank allows the flow to discharge in the open atmosphere so reduces the hydrostatic
pressure to zero. It may be rectangular, circular or square in plan and made of masonry or RCC or Ferro
cement. BPT has provision of a closed chamber with inlet, outlet, overflow and a float valve to stop the
wastage of water and allow reserving at upstream tanks.
A reservoir may also act as a BPT. BPT are provided in the distribution system. If it is used in
transmission line it is called interruption chamber (IC). BPT usually consists consists of float valve but
not in IC. For economical reason, Ferro-cement BPT is preferred.
3. Ferro-cement water tank
Tanks made with chicken wire mesh, cement and sand is called ferro-cement tanks. The ferro-cement
RVT are also designed for balancing demand and supply. The BPT and IC can also be made of ferro-
cement. It reduces the cement, sand, brick, stone and workers but requires skilled person. For a good
ferro-cement tank cement sand ratio must be 1:1.5. Sand should be free from soil otherwise cracks will be
formed. After plastering inside and outside, it must be covered with plastic sheets otherwise water is
evaporated leaving cracks to the tank. It should be cured with water for at least 7 days.
Public tap stand
Public stand post is the point from where people collect water normally in rural area. Tap stand location
in Nepalese practice must be chosen by the villagers themselves and located at the place of non-dispute.
One tap stand for every 8 – 10 households and fetching distance not more than 200 m horizontal and 50 m
vertical is considered in design.
4. Practical Technology
Pipes are subjected to internal forces due to flowing water so suitable anchor blocks are designed to resist
it. In case of stream or river crossing, simple pipe crossing can be provided but if the crossing length is
very high, suspended crossings may be appropriate.
Plantation, barbed wire fencing, catch drains, waste water drain, regular filling of exposed pipelines etc. is
the common practice used for the protection of source, tanks and valve, pipes and tap. Barbed wire
fencing protects from animals and children, human interferences. Regular maintenance for pipe and valve
leakage, clog, tap break, pipe exposure, infrastructure damage etc make structure sustainable. Emergency
maintenance during floods, landslide or natural disasters is needed for resupplying of water. Preventive
measure reduces the maintenance.