Routine Maintenance and Testing of the various equipment's in the plant is one of the most important jobs, which is usually entrusted to experts. We are presenting herewith a case which makes such activities meaningful and can save the assets.
Case Study - How Proactive Electrical Maintenance team saved a Power TransformerSystem Protection
Case Study - How Proactive Electrical Maintenance team saved a Power Transformer. Your valuable 10 minutes may avoid breakdown of Electrical Equipment in your plant.
Practical handbook-for-relay-protection-engineersSARAVANAN A
The ‘Hand Book’ covers the Code of Practice in Protection Circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, Dos and Donts in execution. Also, principles of various protective relays and schemes including special protection schemes like differential,
restricted, directional and distance relays are explained with sketches. The norms of protection of generators, transformers, lines & Capacitor Banks are also given.
Case Study - How Proactive Electrical Maintenance team saved a Power TransformerSystem Protection
Case Study - How Proactive Electrical Maintenance team saved a Power Transformer. Your valuable 10 minutes may avoid breakdown of Electrical Equipment in your plant.
Practical handbook-for-relay-protection-engineersSARAVANAN A
The ‘Hand Book’ covers the Code of Practice in Protection Circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, Dos and Donts in execution. Also, principles of various protective relays and schemes including special protection schemes like differential,
restricted, directional and distance relays are explained with sketches. The norms of protection of generators, transformers, lines & Capacitor Banks are also given.
�The sample calculations shown here illustrate steps involved in calculating the relay settings for generator protection.
�Other methodologies and techniques may be applied to calculate relay settings based on specific applications.
Test done on Power transformers.
Insulation Resistance test, Winding Resistance test, Ratio Measurements, Magnetic balance test, Tan delta test, DIssolved gas analysis for transformer, Sweep frequency response analysis.
�The sample calculations shown here illustrate steps involved in calculating the relay settings for generator protection.
�Other methodologies and techniques may be applied to calculate relay settings based on specific applications.
The protections of generator are the most complex and elaborate due to the following reasons: Generator is a large machine, connected to bus-bars. It is accompanied by unit transformers, auxiliary transformers and a bus system. ... The protection of generator should be co-ordinate with associated equipment's.
On Load Tap Changer (OLTC) is used in "High Power Transformers" to control output voltage, when electric load on transformers get increase the output voltage get decrease due to internal voltage drop inside winding, change in tap is required to maintain output voltage. OLTC is a device which perform tap changing in High Power Transformers during On Load conditions and is powered by a motor.
�The sample calculations shown here illustrate steps involved in calculating the relay settings for generator protection.
�Other methodologies and techniques may be applied to calculate relay settings based on specific applications.
Test done on Power transformers.
Insulation Resistance test, Winding Resistance test, Ratio Measurements, Magnetic balance test, Tan delta test, DIssolved gas analysis for transformer, Sweep frequency response analysis.
�The sample calculations shown here illustrate steps involved in calculating the relay settings for generator protection.
�Other methodologies and techniques may be applied to calculate relay settings based on specific applications.
The protections of generator are the most complex and elaborate due to the following reasons: Generator is a large machine, connected to bus-bars. It is accompanied by unit transformers, auxiliary transformers and a bus system. ... The protection of generator should be co-ordinate with associated equipment's.
On Load Tap Changer (OLTC) is used in "High Power Transformers" to control output voltage, when electric load on transformers get increase the output voltage get decrease due to internal voltage drop inside winding, change in tap is required to maintain output voltage. OLTC is a device which perform tap changing in High Power Transformers during On Load conditions and is powered by a motor.
This presentation will give you an understanding of self contained and transformer rated current transformers. You will also discuss meter testing, CT testing, ratio & burden testing
This presentation discusses:
- Best practices regarding the need to ensure that all transformers used for metering circuits are properly sized
- The ability to optimize revenue regardless of customer usage over time
- Best practices to ensure that transformers and meters have been installed correctly in the field and continue to perform in the same fashion
- Best practices for certifying the accuracy class of the transformers and how to best set up a shop testing and field testing/verification program.
- What the costs of implementing such a system and what the costs of not implementing such a system can be.
This presentation was for an Advanced Session at North Carolina Meter School and discussed CT functionality Basics, Terminology and Specifications, Ratio Testing, Burden Testing, Admittance Testing, and Demag Functions.
This presentation will cover the basics and differences between self-contained and transformer or instrument rated meter sites. Also discussed are transformer rated meter forms, test switches and CT's, Blondel's Theorem and why this matters to metering, meter accuracy testing in the field, checking the health of your CT's and PT's, and Site Verification (and not just meter testing).
This presentation discusses self-contained vs. transformer rated CTs, functions and terminology, CT testing, ratio testing, burden testing, and more. This was given during the North Carolina Electric Meter School in June 2018.
Reyrolle 7SR54 provides protection, control and monitoring of 2 and 3 winding transformers. All transformer vector groups and earthing connections are supported.
Mastering Motor Protection with SIEMENS Reyrolle 7SR17: Safeguarding Your AssetsSystem Protection
Discover the Power of SIEMENS Reyrolle 7SR17 Rho Motor Protection Relay! 🔌🔒
In this informative video, we delve deep into the world of motor protection with the cutting-edge SIEMENS Reyrolle 7SR17 Rho numeric protection relay. With four current inputs and the option for three voltage inputs, this relay is a game-changer for safeguarding motors and their connections.
Join us as we explore the features, applications, and benefits of the 7SR17 Rho, and learn how it provides a seamless and integrated protection system to ensure the longevity and efficiency of your valuable assets.
Don't miss out on this essential guide to motor protection technology. Hit that like button, subscribe for more insightful content, and empower your engineering knowledge with SIEMENS Reyrolle 7SR17 Rho!"
AC Digital Clamp Meter KEW 2204R Overview | System ProtectionSystem Protection
The AC Digital Clamp Meter KEW 2204R is likely a tool designed for measuring electrical parameters in alternating current (AC) circuits. These meters are commonly used by electricians, technicians, and engineers for various applications.
Digital Multimeter with AC/DC Clamp Sensor KEWMATE 2012RA | System ProtectionSystem Protection
Digital Multimeter with AC/DC Clamp Sensor
KEWMATE 2012RA
• Innovative Multimeters with current measurements up to 120A AC/DC
• Unique Open Jaw technology for AC/DC current measurements
• Very compact and as reliable as a tradictional full size multimeter
A digital multimeter (DMM) is a versatile electronic instrument used to measure various electrical parameters like voltage, current, resistance, capacitance, and frequency. These meters come with a digital display that provides more accurate readings compared to analog meters.
The Kyoritsu KEW 5711 is a non-contact voltage tester used to detect the presence of AC voltage in electrical systems, outlets, cables, circuit breakers, and other live conductors. It is designed to ensure the safety of the user by alerting them to the presence of voltage without the need for physical contact.
Earth Clamp Testing with the KEW 4202 | Ultimate Tool for Earth Clamp TestingSystem Protection
Are you in need of a reliable and efficient tool for earth clamp testing? Look no further than the KEW 4202 Earth Clamp Tester. This powerful device has a wide measurement range of 0.05Ω to 1200Ω, making it suitable for a variety of applications. It also features a large, easy-to-read display and a simple, user-friendly interface, making it easy to get accurate readings quickly and efficiently.
But that's not all. The KEW 4202 also offers a number of advanced features, such as data logging and USB connectivity, which allow you to store and analyze your measurements with ease. It even has a unique "noise check" function that ensures accurate measurements in noisy environments.
Overall, the KEW 4202 is the ultimate tool for earth clamp testing, thanks to its combination of accuracy, convenience, and advanced features. Whether you're an electrician, engineer, or DIY enthusiast, this device is sure to become an essential part of your toolkit.
Kyoritsu Kew 6016 Multi-Function Tester is a premium quality product from Kyoritsu. All Kyoritsu Kew 6016 Multi-Function Tester are manufactured by using quality assured material and advanced techniques, which make them up to the standard in this highly challenging field.
Honeywell Arc Flash Personal Protection Equipment Kits are available in an ATPV rating of 40 Cal /cm2. This kit contains an arc flash coat, bib overalls, hardhat, SKBAG, and safety glasses, Optional Lift Front Hood. Sizes S, M, L, XL, 2XL are available from stock, other sizes and color available by special order. These kits meet NFPA 70E Hazard Risk Category 4.
The Honeywell Insulating Mats provide a unique solution to protect workers against electric shock across substations, transformer rooms, LT and HT control panels, electrical switch rooms for AC and DC installations, battery rooms, and generator set rooms.
Salisbury By Honeywell | 51511 Di – Electric Over ShoesSystem Protection
Salisbury’s dielectric boots are 100% waterproof and made from premium grade ozone resistant rubber. The flexible hand-layered construction includes a durable nylon lining for easy on/off. Salisbury Dielectric Footwear conforms with ASTM F1117 and is tested to ASTM F1116 at 20kV.
Salisbury By Honeywell | 4556 Voltage Detector 240V to 230kVSystem Protection
The Salisbury 4556 is a high voltage detection kit for use in applications for voltages from 240V to 230kV. It is intended for use in verifying the live or de-energized status of conductors, bus bars, and other types of exposed electrical equipment.
Improving profitability for small businessBen Wann
In this comprehensive presentation, we will explore strategies and practical tips for enhancing profitability in small businesses. Tailored to meet the unique challenges faced by small enterprises, this session covers various aspects that directly impact the bottom line. Attendees will learn how to optimize operational efficiency, manage expenses, and increase revenue through innovative marketing and customer engagement techniques.
What is the TDS Return Filing Due Date for FY 2024-25.pdfseoforlegalpillers
It is crucial for the taxpayers to understand about the TDS Return Filing Due Date, so that they can fulfill your TDS obligations efficiently. Taxpayers can avoid penalties by sticking to the deadlines and by accurate filing of TDS. Timely filing of TDS will make sure about the availability of tax credits. You can also seek the professional guidance of experts like Legal Pillers for timely filing of the TDS Return.
At Techbox Square, in Singapore, we're not just creative web designers and developers, we're the driving force behind your brand identity. Contact us today.
3.0 Project 2_ Developing My Brand Identity Kit.pptxtanyjahb
A personal brand exploration presentation summarizes an individual's unique qualities and goals, covering strengths, values, passions, and target audience. It helps individuals understand what makes them stand out, their desired image, and how they aim to achieve it.
Personal Brand Statement:
As an Army veteran dedicated to lifelong learning, I bring a disciplined, strategic mindset to my pursuits. I am constantly expanding my knowledge to innovate and lead effectively. My journey is driven by a commitment to excellence, and to make a meaningful impact in the world.
Implicitly or explicitly all competing businesses employ a strategy to select a mix
of marketing resources. Formulating such competitive strategies fundamentally
involves recognizing relationships between elements of the marketing mix (e.g.,
price and product quality), as well as assessing competitive and market conditions
(i.e., industry structure in the language of economics).
Discover the innovative and creative projects that highlight my journey throu...dylandmeas
Discover the innovative and creative projects that highlight my journey through Full Sail University. Below, you’ll find a collection of my work showcasing my skills and expertise in digital marketing, event planning, and media production.
Falcon stands out as a top-tier P2P Invoice Discounting platform in India, bridging esteemed blue-chip companies and eager investors. Our goal is to transform the investment landscape in India by establishing a comprehensive destination for borrowers and investors with diverse profiles and needs, all while minimizing risk. What sets Falcon apart is the elimination of intermediaries such as commercial banks and depository institutions, allowing investors to enjoy higher yields.
Recruiting in the Digital Age: A Social Media MasterclassLuanWise
In this masterclass, presented at the Global HR Summit on 5th June 2024, Luan Wise explored the essential features of social media platforms that support talent acquisition, including LinkedIn, Facebook, Instagram, X (formerly Twitter) and TikTok.
Buy Verified PayPal Account | Buy Google 5 Star Reviewsusawebmarket
Buy Verified PayPal Account
Looking to buy verified PayPal accounts? Discover 7 expert tips for safely purchasing a verified PayPal account in 2024. Ensure security and reliability for your transactions.
PayPal Services Features-
🟢 Email Access
🟢 Bank Added
🟢 Card Verified
🟢 Full SSN Provided
🟢 Phone Number Access
🟢 Driving License Copy
🟢 Fasted Delivery
Client Satisfaction is Our First priority. Our services is very appropriate to buy. We assume that the first-rate way to purchase our offerings is to order on the website. If you have any worry in our cooperation usually You can order us on Skype or Telegram.
24/7 Hours Reply/Please Contact
usawebmarketEmail: support@usawebmarket.com
Skype: usawebmarket
Telegram: @usawebmarket
WhatsApp: +1(218) 203-5951
USA WEB MARKET is the Best Verified PayPal, Payoneer, Cash App, Skrill, Neteller, Stripe Account and SEO, SMM Service provider.100%Satisfection granted.100% replacement Granted.
RMD24 | Debunking the non-endemic revenue myth Marvin Vacquier Droop | First ...BBPMedia1
Marvin neemt je in deze presentatie mee in de voordelen van non-endemic advertising op retail media netwerken. Hij brengt ook de uitdagingen in beeld die de markt op dit moment heeft op het gebied van retail media voor niet-leveranciers.
Retail media wordt gezien als het nieuwe advertising-medium en ook mediabureaus richten massaal retail media-afdelingen op. Merken die niet in de betreffende winkel liggen staan ook nog niet in de rij om op de retail media netwerken te adverteren. Marvin belicht de uitdagingen die er zijn om echt aansluiting te vinden op die markt van non-endemic advertising.
Affordable Stationery Printing Services in Jaipur | Navpack n PrintNavpack & Print
Looking for professional printing services in Jaipur? Navpack n Print offers high-quality and affordable stationery printing for all your business needs. Stand out with custom stationery designs and fast turnaround times. Contact us today for a quote!
The key differences between the MDR and IVDR in the EUAllensmith572606
In the European Union (EU), two significant regulations have been introduced to enhance the safety and effectiveness of medical devices – the In Vitro Diagnostic Regulation (IVDR) and the Medical Device Regulation (MDR).
https://mavenprofserv.com/comparison-and-highlighting-of-the-key-differences-between-the-mdr-and-ivdr-in-the-eu/
2. Routine Maintenance and Testing of the
various equipment's in the plant is one of
the most important jobs, which is usually
entrusted to experts. We are presenting
herewith a case which makes such activities
meaningful and can save the assets.
During these activities, one day, the
Engineer-in-Charge informed us that there
is a long-pending problem in LT PCC
Incomer Feeder, and whether we can solve
it. The Earth Fault element operated every
time the load increased beyond a certain
limit (but within TR limit). As it was a
continuous process plant, they had turned
off the Earth Fault protection and were
running the feeder without the Earth Fault
protection. They wanted to take this
protection in line.
In Derived type Earth Fault protection,
current to the relay is fed from the Phase
CTs only. From the available Phase currents,
relay calculates the residual current which
is represented as the Earth Fault current.
Hence, inside the relay, vector summation
of Phase currents (Ia, Ib & Ic) is carried out
and Earth Fault current (In) is derived.
Unbalancing in the three phase currents
can be due to unbalance loading condition
also.
www.systemprotection.in +91-265-2225137
We were appointed to carry out the routine
maintenance and testing of the
Switchgears, Relays, CTs & PTs in one of the
Continuous Process Plants in India.
Findings :
As per the EIC, the plant operated on low
loads and there was no evident fault (i.e.,
short circuit or considerable leakage).
Upon checking, Earth Fault protection was
found to be of Derived type.
Above vector sum is always zero in normal
condition. Hence, if the Earth Fault element
operates, it is understood that this
summation is non-zero, there is some
unbalancing in three phase currents, which
is higher than the adopted settings.
As the entire loading was 3-Ø and balanced,
there was no question of unbalancing.
As, it can be seen (Image 1) on the relay,
Current in the Neutral is around 610 A. Earth
Fault Pick-up was set at 400 A in the relay.
Hence, relay kept operating when it sensed
higher current. Phase CTs were having a
ratio of 4000/1 A and the Earth Fault
element was set at 400 A, i.e., 10 %.
Root Cause Analysis
The programming of the relay was found in
order. Tripping relays were assigned and
operated as per drawings.
The Relay was tested by secondary injection
method and found healthy.
The wiring to relay from CT and the CT links
were found alright. It was decided then to
check the CTs for its various characteristics.
3. Usually, for higher rating CTs, Primary
Injection at Site is done at comparatively
lower currents, due to size and weight
limitations posed by higher current -
injection kits. Besides, even if we somehow
manage to inject such heavy currents, it
does not usually lead to conclusive Ratio
Measurement. High currents generate
considerable heat in the injection cables
(due to I2t), which in turn results in
fluctuation of currents, as the cable
resistance keep on changing due to
heating. Moreover, measurement of such
large primary currents with Clamp-on Meter
is also a challenge.
So, we employed a state-of-the-art CT
Testing Instrument, CT Analyzer of Omicron
Make, which uses IEC 61869-2 standard and
performs model-based testing which is far
more accurate and conclusive.
www.systemprotection.in +91-265-2225137
The following are the results of Y Phase
CT :
CT Analyzer Test
Results for Y Phase
CT
We found that R and B Phase CTs were
having minor errors, but Y phase CT had a
ratio error of 50 % at rated burden. It
means, CT will act as it is having a ratio of
4000/0.5 A instead of 4000/1 A. Phase angle
error was also found to be -1574.06 min.
Due to high errors (Magnitude and Phase
angle) of Y Phase CT, relay mal-operated in
Earth Fault element.
The faulty CT was replaced with a new CT
after proper testing and wiring, the
Transformer was switched on and re-
commissioned with loading.
Conclusion – how
advanced technology
can help solve such
issues more
accurately
At times, routine test equipments, such as
Primary Injection Kit, do not provide the
conclusive results. It is likely that the fault in
the equipment may go unnoticed /
unchecked despite carrying out Routine
Testing.
Upgrading ourselves constantly with
advanced technology has always been at
the forefront for us, and we invest heavily in
such technology so that our Customers can
keep their protection systems safer and
more reliable.
Transformer is a very important asset, and
the loss of production due to mal-operation
of its protection system, can run into crores.
All our efforts are viewing the problems
from customers’ point and resolving them
in totality.
4. The above was in fact the major problem
found, we also observed some minor
abnormalities and corrected them too.
There could be many reasons for mal-
operation of Transformer Protection System
and can be addressed on case-to-case basis.
To know more, you may call/write to us.
And if you are looking for a dedicated
agency that understands the direct link
between your assets and your revenue,
call/write to us, we will be happy to assist
you.
www.systemprotection.in +91-265-2225137
5. CONTACT INFORMATION
301/2/306, Silverline Complex,Opposite BBC
Tower,Sayajigunj,Vadodara - 390 005,
Gujarat, India.
bdm@systemprotection.in
www.systemprotection.in
+91-265-2225137