BOILER Mae Sod Clean Energy Co., Ltd. IJT
BOILER Start Normal state MILL B1 B3 B2 B4 B5 B9 B6 B7 B8 Belt size B1  ขนาด  1000 mm.BW.x33.5 M.L.       11  kw B2  ขนาด 1000 mm.BW.x14.7 M.L.       7.5  kw B3  ขนาด  1000 mm.BW.x214 M.L.       30  kw B4  ขนาด  1000 mm.BW.x14.7 M.L.      7.5  kw B5  ขนาด  1200 mm.BW.x43 M.L.         22  kw B6  ขนาด  900 mm.BW.x38 M.L.            11  kw B7  ขนาด  900 mm.Bw.x73 M.L.             15  kw B8  ขนาด  1500 mm.BW.x9 M.L.            5.5  kw B9  ขนาด  900 mm.BW.x89 M.L.           11  kw
INTER LOCK BELT CONVEYOR NO. START Normal state FORM RUNING NO. FORM RUNING NO. B.1 OFF ▬ ON 9 B.2 ON 2 ON 2 B.3 ON 1 ON 1 B.4 ON 4 ON 4 B.5 ON 3 ON 3 B.6 ON 5 OFF ▬ B.7 ON 6 OFF ▬ B.8 ON 7 OFF ▬ B.9 ON 8 ON 8
 
FURNACE DRUM STOKER การไหลของ เชื้อเพลิง , ลม , แก๊สและขี้เถ้า  IJT Boiler Steam   Boiler Cap.  : 95 TPH Pres.  : 60 Bar Temp.  : 500 °C F.W.P.  : 160°C Bag. feed  : 4 set Bag. Ext.  :  13000kg/hr
Boiler  สำหรับโรงไฟฟ้า ทำหน้าที่  2  อย่างคือ เผาไหม้เชื้อเพลิงเพื่อสร้างความร้อน  และ  ใช้ความร้อนนั้นเปลี่ยนน้ำให้เป็นไอน้ำ
วงจรของ   Boiler   โดยทั่วไปจะแบ่งออกเป็น  4  ส่วนใหญ่ๆ คือ Air & Gas system  Water & Steam system Fuel Handling system Ash Handling system
superheat economizer 200  ๐ C 160  ๐ C 800   ๐ C
 
COMBUSTION AIR SYSTEM การเผาไหม้ คือปฏิกิริยาทางเคมีระหว่างเชื้อเพลิงกับ  Oxygen  เพื่อที่จะให้เกิดการเผาไหม้ จะต้องมีส่วนประกอบทั้ง  4  อย่างคือ  Oxygen ,  Fuel ,      Heat( ความร้อน ) และ  Chemical reaction( ปฏิกิริยาเคมี )  เมื่อใดก็ตามที่มีทั้ง  4  อย่างดังกล่าว  การเผาไหม้จะเริ่มต้นและสามารถที่จะดำเนินต่อไปได้เองถ้าสิ่งหนึ่งสิ่งใดขาดหายไปการเผาไหม้ก็จะหยุดลง
เชื้อเพลิง  คือสารที่เผาไหม้ได้และใช้ผลิตพลังงานความร้อนโดยการเผาไหม้  ในที่นี้ เชื้อเพลิงที่ใช้ในการเผาไหม้คือ กากอ้อย Bagasse analysis Hydrogen  :  3.04  % Carbon  :  23.24 % Oxygen  :  22.08 % Moisture  :   50.0  % HHV  :  2272Kcal / Kg
เพื่อให้การเผาไหม้นั้นจะสมบูรณ์ Turbulence  เพื่อผสมเชื้อเพลิงกับอากาศอย่างทั่วถึง  และ Time  ระยะเวลาในการเผาไหม้
ในขบวนของการที่จะเผาไหม้  เชื้อเพลิงกากอ้อย ต้องผสมกับออกซิเจน อย่างทั่วถึง เมื่อเผาไหม้แล้วก็ให้ความร้อนออกมา  ทุกๆองค์ประกอบในเชื้อเพลิงจะผสมกับอ๊อกซิเจน  แต่จะมีเพียง  3  องค์ประกอบเท่านั้นที่เผาไหม้  คือ  Carbon  Hydrogen  Sulphur
Carbon  มีประโยชน์ในการเผาไหม้มากที่สุด ปริมาณมากที่สุดและเผาไหม้ได้ง่าย  Sulphur  จะมีปัญหามากที่สุด เพราะก่อให้เกิดมลพิษ แต่กากอ้อยมีเปอร์เซ็นต์ ของ   sulphur  น้อยมาก Oxygen  ที่มีอยู่ในเชื้อเพลิง ไม่เพียงพอที่ทำให้ก่อประโยชน์ใดๆได้ Nitrogen  ซึ่งโดยปกติแล้วไม่ติดไฟ แต่จะสามารถรวมกับองค์ประกอบอื่นในระหว่าง   การเผาไหม้ เกิดเป็นมลพิษขึ้นมาได้และต้องควบคุม Ash  เป็นคำซึ่งใช้อธิบายของแข็ง ไม่ติดไฟ  ทำให้เกิดปัญหา หลายประการ  -  เป็นส่วนประกอบของเชื้อเพลิงที่ต้องสูญไปโดยเปล่าประโยชน์ -  เป็นสาเหตุให้เกิดการกัดกร่อน  (Corrosion) -  การสึกกร่อน (Erosion)  ซึ่งสามารถนำไปสู่การแตกหัก เสียหาย  -  และประการสุดท้าย ปัญหาที่จะต้องกำจัด  Ash
 
 
ท่อเหล่านี้รวมกันเรียกว่า  WaterWalls
IJT 60kg/cm 2 ค่าควบคุมมาตรฐานคุณภาพน้ำในหม้อไอน้ำ ณ ความดันไอน้ำต่างกัน Boiler water Quality Recommendation At Increasing  Pressure ( All value,except ; given in ppm ) in Sugar Industry             Intermediate             Low to 250 psi 250 -300 psi 300 - 450 psi   0 - 15 kg/cm 2 15 - 20 kg/cm 2 2 0 - 30 kg/cm 2 Total hardness, as Ca CO 3 0 0 0 Total Alkalinty, as Ca CO 3 700 700 700 Hydroxide, as Ca CO 3 150 - 300 150 - 300 130 Silica, as SiO 2 100 - 133 50 - 67 50 - 67 Dissolved Oxygen 0.015 0.015 0.015 Total Dissolved Solid < 2,500 < 2,000 < 1,500 Suspended  Solid < 600 < 300 < 200 Conductivity, micro - mho / cm < 3,500 < 2,850 < 2,150 PH 11 - 11.8 11 - 11.5 10.5 - 11.5 Oil 1.0 1.0 1.0 Sodium Sulphite ; as Na 2  SO 3 30 - 60 30 - 40 20 - 30 Phosphate ; as PO 4 3- 20 - 40 20 - 40 5. - 15 Hydrazine ;  as N 2  H 4 0.1 - 0.3 0.1 - 0.4 0.1 - 0.5                     จากหนังสือ   การประหยัดพลังงานความร้อน     ปี  2531   บทที่  5  เรื่องการปรับสภาพน้ำ     สำนักงานพลังงานแห่งชาติ Nil 2.5 100 200 9.5-10.5 20
WATER TREATMENT & BOILER FEED WATER RAW WATER FILTERING FILTERED WATER SOFTENING RO DEMINERALIZATION THERMAL DEAERATION MAKE - UP WATER
CONDENSATE POLISHING ADDITTIVE INJECTION THERMAL DEAERATION FEED  WATER BOILER WATER STEAM CONDENSATE BLOW - DOWN 160 °C IJT
การหมุนเวียน  ( Circulation )  ใน  boiler   เป็นสิ่งจำเป็นด้วยเหตุผล  2  ประการ ประการแรกคือ  การตระเตรียมปริมาณน้ำที่  supply   ให้พอดีในการเปลี่ยนน้ำนั้น    ให้กลายเป็นไอน้ำ  ประการที่สองคือ  น้ำนั้นจะต้องพาเอาความร้อนของ  boiler furnace   ออกไป จาก  waterwalls   ถ้าการไหลของน้ำลดลงหรือถูกตัดออกไป  ท่อน้ำก็จะ  overheat   และแตกในที่สุด Water Flow Path
ความร้อนที่ได้จากการเผาไหม้   จะถูกถ่ายเทไปให้กับ  steam   และน้ำ  โดยผ่านท่อที่ประกอบเป็นผนังเตา  ท่อผนังเตาทำด้วย  carbon steel   ทนอุณหภูมิสูงสุดได้ประมาณ  482  ° c   อุณหภูมิของ  steam/water mixture   ภายในท่อจะอยู่ที่ประมาณ 260  ° c   อุณหภูมิของ  superheater steam   ภายในท่อจะมีอุณหภูมิประมาณ  500   ° c   ขณะที่  gas   นอกท่ออาจสูงถึง  >1,000  ° c   เนื้อโลหะของ  superheater   จะทนได้ประมาณ  600  ° c   โดยมี น้ำและ  steam flow   อยู่ในท่อเป็นตัวรักษาอุณหภูมิไม่ให้เกินลิมิต ( Limit )  ที่มันทนได้
ขณะทำการ   Start-up   ใหม่ๆ ปริมาณ  Steam Flow   จากการเปิด  vent   และ  drain  superheat   จะยังมีน้อยมาก  เมื่อน้ำที่มีอยู่ในท่อ  superheat   หมดไป  อุณหภูมิจะเพิ่มขึ้นทันทีโดยจะสูงเท่ากับอุณหภูมิของ  superheater steam   จึงต้องปรับอัตราของ  firing   ควบคุมไม่ให้  furnace gas temp .  เกิน  537 °c  ก่อนที่กังหันจะเริ่มรับ  load   และมี  steam flow   ผ่านท่อ  superheater   มากพอ  เพื่อให้  superheater   metal temperature   ต่ำกว่าค่าสูงสุดที่โลหะทนได้  ( ประมาณ  600 ° c   )  ถ้า  firing rate   หรืออัตราการป้อนเชื้อเพลิงเร็วไป  จะทำให้  superheater   metal temperature   สูงเกินค่าที่โลหะทนได้  เพราะความร้อนที่เพิ่มขึ้น เร็วกว่าค่าความร้อนที่  steam   สามารถรับเอาไว้ หรือท่อโลหะคายความร้อนให้  steam   ไม่ทันนั่นเอง
การพา การแผ่รังสี การถ่ายเทความร้อน   ( Heat Transfer ) การพา
 
การไหลเวียน   (Circulation) ความร้อนจำนวนมหาศาลที่ผนังเตา และ  superheater   รับเข้าไว้  มีเพียง  fluid  ( น้ำ หรือไอน้ำ )  ที่อยู่ภายในท่อเท่านั้นที่เป็นตัวดึงความร้อนนี้ ออกไปและดึงอุณหภูมิของท่อไว้ให้ต่ำกว่า  safe limit   ไม่ให้ท่อเสียหาย  การไหลเวียนอย่างต่อเนื่องของ  fluid   จึงป้องกันไม่ให้ท่อร้อนจนเกินไป  (overheat)   การไหลเวียนของน้ำผ่าน  water walls   จะแบ่งออกเป็น  3  แบบ  Natural circulation   ไหลเวียนตามธรรมชาติ Forced circulation   ไหลเวียนตามธรรมชาติ  โดยมี  circulating pump   ช่วยการไหลเวียน Once through   ไหลผ่านรวดเดียว
เตา  furnace
การควบคุมการเผาไหม้
จะต้องควบคุม  acidity   ของน้ำที่ใช้ด้วย  (  ค่าความเป็นกรด )  acidity   เราวัดด้วย  pH   ค่า  pH  = 7  หมายถึง น้ำมีค่าเป็นกลาง ถ้า  pH  ต่ำกว่า  7  น้ำมีฤทธิ์เป็นกรด ถ้า  pH  สูงกว่า  7  น้ำมีฤทธิ์เป็นด่าง เพื่อไม่ให้หม้อน้ำและท่อเกิดการกัดกร่อน  น้ำที่ไหลภายในท่อจะต้องไม่มีฤทธิ์เป็นกรด
Acid Attcak   ถ้า  pH   ต่ำกว่า  7  น้ำมีฤทธิ์เป็นกรด  จะสามารถกัดเนื้อเหล็กออกจากผนังท่อได้  Caustic Attack  ถ้า  pH  สูงกว่า  7  มากๆ  น้ำมีฤทธิ์เป็นด่าง  จะทำให้เหล็กกร่อนได้เช่นเดียวกัน  การป้องกัน  corrosion   เราจะต้องคุม ค่า  pH  และกำจัดแก๊สที่เจือปนในน้ำ
scale   ที่เกาะภายในท่อจะทำหน้าที่คล้ายฉนวน ทำให้ท่อเกิด  overheat   และแตกในที่สุด  Scale  เกิดจากสารอยู่ในน้ำจะประกอบด้วย สารแขวนลอย   (suspended   solids)     สารละลาย   (dissolved solids) สารแขวนลอย   คือตะกอน , โคลน , สิ่งสกปรกที่มีอยู่ในน้ำการสกัดออกโดยใช้  clarifier   สารละลาย   คือเกลือแร่ที่น้ำได้ละลายไว้  ซึ่งพบเสมอได้แก่  silica  ( Sio2- ซิลิกอนไดออกไซด์ )  เป็นสารประกอบจำพวก เหล็ก , แคลเซียม และ แมกนีเซียม
หม้อน้ำ เมื่อไอน้ำเกิดขึ้นและถูกส่งออกจาก   steam drum   แล้วสิ่งสกปรกจะตกค้างอยู่ภายในหม้อน้ำและเพิ่มความเข้มข้นขึ้น (  คือ เกลือกระด้าง  ได้แก่ แคลเซียม และแมกนีเซียม  )   ถ้าปล่อยทิ้งไว้นานเข้าจะกลายเป็นตะกรัน เกาะตามผนังภายในท่อ และ  steam drum   ผล ประสิทธิภาพลดลง  เพราะการถ่ายเทความร้อนได้ยากขึ้น  ผลเสียหายร้ายแรงที่เกิดจากการเกิดตะกรัน  คือท่อแตก  เราควบคุม  concentration   ( ความเข้มข้น )  ได้โดยวิธี  continuous   blowdown
การเติมสาร ฟอสเฟต  ( phosphate )  ลงไปในหม้อน้ำ   จะช่วยให้ลดความกระด้างอันเนื่องมาจากแคลเซี่ยมและแมกนีเซี่ยมในหม้อน้ำได้  ฟอสเฟต จะจับแคลเซี่ยมและแมกนีเซี่ยม ในน้ำให้รวมตัวกันเป็น  Sludge   ( ขี้โคลน , ตะกอน )  จึงป้องกันการเกิด  hard scale  ( ตะกรันแข็ง )  การทำ   continuous  blowdown   จะกำจัดสารเคมีบางส่วนที่จำเป็นสำหรับหม้อน้ำทิ้งไปพร้อมๆกับสสารอื่นๆ  ดังนั้นจึงจำเป็นต้องเติมสารเคมีชดเชยส่วนที่สูญเสียไป
ทุกๆวันพนักงานเคมีฯ   จะต้องนำน้ำในหม้อน้ำไปตรวจวิเคราะห์เพื่อหาค่า silica , phosphate , total solids   ( ปริมาณสารของแข็งทั้งหมดที่มีอยู่ในน้ำ )  และ  pH

More Related Content

What's hot

Industrial fan(ID FD Fans)
Industrial fan(ID FD Fans)Industrial fan(ID FD Fans)
Industrial fan(ID FD Fans)
Amaresh Choudhary
 
AFBC BOILERS PERFORMANCE IMPROVEMENT
AFBC BOILERS PERFORMANCE IMPROVEMENTAFBC BOILERS PERFORMANCE IMPROVEMENT
AFBC BOILERS PERFORMANCE IMPROVEMENT
Manohar Tatwawadi
 
Direct heated rotary dryer
Direct heated rotary dryerDirect heated rotary dryer
Direct heated rotary dryer
Arberor MITA
 
Steam Reforming - Catalyst Loading
Steam Reforming - Catalyst LoadingSteam Reforming - Catalyst Loading
Steam Reforming - Catalyst Loading
Gerard B. Hawkins
 
Boiler Presentation
Boiler PresentationBoiler Presentation
Boiler Presentation
anshsmartstud
 
Boiler Operation
Boiler OperationBoiler Operation
Boiler Operation
Susovan Sensharma
 
Shell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat TransferShell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat Transfer
Usman Shah
 
Naphtha Steam Reforming Catalyst Reduction with Methanol
Naphtha Steam Reforming Catalyst Reduction with MethanolNaphtha Steam Reforming Catalyst Reduction with Methanol
Naphtha Steam Reforming Catalyst Reduction with Methanol
Gerard B. Hawkins
 
Heat exchanger: Shell And Tube Heat Exchanger
Heat exchanger: Shell And Tube Heat ExchangerHeat exchanger: Shell And Tube Heat Exchanger
Heat exchanger: Shell And Tube Heat Exchanger
Akshay Sarita
 
Usage of Support Balls, Meshes & Hold Down Screens
Usage of Support Balls, Meshes & Hold Down ScreensUsage of Support Balls, Meshes & Hold Down Screens
Usage of Support Balls, Meshes & Hold Down Screens
Gerard B. Hawkins
 
Rules of thumb for process engineer
Rules of thumb for process engineerRules of thumb for process engineer
Rules of thumb for process engineer
Karnav Rana
 
Cooling tower calculation (1) (1)
Cooling tower calculation (1) (1)Cooling tower calculation (1) (1)
Cooling tower calculation (1) (1)
Jose Soto Evangelista
 
Pressure Reliveing Devices1
Pressure Reliveing Devices1Pressure Reliveing Devices1
Pressure Reliveing Devices1Om Pratap Singh
 
Steam Boilers OR Steam Generators
Steam Boilers OR Steam GeneratorsSteam Boilers OR Steam Generators
Steam Boilers OR Steam Generators
Hrishikesh Devan
 
Boiler Drum And Its Internals
Boiler Drum And Its InternalsBoiler Drum And Its Internals
Boiler Drum And Its Internals
Ashrant Dass
 
Cb gf web in aug 2016, controls r2 8.23.16 final
Cb gf web in aug 2016, controls r2 8.23.16 finalCb gf web in aug 2016, controls r2 8.23.16 final
Cb gf web in aug 2016, controls r2 8.23.16 final
lorenzo Monasca
 
Process Calculation - simple distillation
Process Calculation - simple distillationProcess Calculation - simple distillation
Process Calculation - simple distillation
Chandran Udumbasseri
 
Heat Exchanger (Shell and tubes) by sujan kharel..
Heat Exchanger (Shell and tubes) by sujan kharel..Heat Exchanger (Shell and tubes) by sujan kharel..
Heat Exchanger (Shell and tubes) by sujan kharel..
ansaluniversity3
 
Boiler calculations
Boiler calculationsBoiler calculations
Boiler calculations
Usman Shahdin
 
Vertical roller mill routine maintenance note
Vertical roller mill routine maintenance noteVertical roller mill routine maintenance note
Vertical roller mill routine maintenance note
Zhengzhou
 

What's hot (20)

Industrial fan(ID FD Fans)
Industrial fan(ID FD Fans)Industrial fan(ID FD Fans)
Industrial fan(ID FD Fans)
 
AFBC BOILERS PERFORMANCE IMPROVEMENT
AFBC BOILERS PERFORMANCE IMPROVEMENTAFBC BOILERS PERFORMANCE IMPROVEMENT
AFBC BOILERS PERFORMANCE IMPROVEMENT
 
Direct heated rotary dryer
Direct heated rotary dryerDirect heated rotary dryer
Direct heated rotary dryer
 
Steam Reforming - Catalyst Loading
Steam Reforming - Catalyst LoadingSteam Reforming - Catalyst Loading
Steam Reforming - Catalyst Loading
 
Boiler Presentation
Boiler PresentationBoiler Presentation
Boiler Presentation
 
Boiler Operation
Boiler OperationBoiler Operation
Boiler Operation
 
Shell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat TransferShell and Tube Heat Exchanger in heat Transfer
Shell and Tube Heat Exchanger in heat Transfer
 
Naphtha Steam Reforming Catalyst Reduction with Methanol
Naphtha Steam Reforming Catalyst Reduction with MethanolNaphtha Steam Reforming Catalyst Reduction with Methanol
Naphtha Steam Reforming Catalyst Reduction with Methanol
 
Heat exchanger: Shell And Tube Heat Exchanger
Heat exchanger: Shell And Tube Heat ExchangerHeat exchanger: Shell And Tube Heat Exchanger
Heat exchanger: Shell And Tube Heat Exchanger
 
Usage of Support Balls, Meshes & Hold Down Screens
Usage of Support Balls, Meshes & Hold Down ScreensUsage of Support Balls, Meshes & Hold Down Screens
Usage of Support Balls, Meshes & Hold Down Screens
 
Rules of thumb for process engineer
Rules of thumb for process engineerRules of thumb for process engineer
Rules of thumb for process engineer
 
Cooling tower calculation (1) (1)
Cooling tower calculation (1) (1)Cooling tower calculation (1) (1)
Cooling tower calculation (1) (1)
 
Pressure Reliveing Devices1
Pressure Reliveing Devices1Pressure Reliveing Devices1
Pressure Reliveing Devices1
 
Steam Boilers OR Steam Generators
Steam Boilers OR Steam GeneratorsSteam Boilers OR Steam Generators
Steam Boilers OR Steam Generators
 
Boiler Drum And Its Internals
Boiler Drum And Its InternalsBoiler Drum And Its Internals
Boiler Drum And Its Internals
 
Cb gf web in aug 2016, controls r2 8.23.16 final
Cb gf web in aug 2016, controls r2 8.23.16 finalCb gf web in aug 2016, controls r2 8.23.16 final
Cb gf web in aug 2016, controls r2 8.23.16 final
 
Process Calculation - simple distillation
Process Calculation - simple distillationProcess Calculation - simple distillation
Process Calculation - simple distillation
 
Heat Exchanger (Shell and tubes) by sujan kharel..
Heat Exchanger (Shell and tubes) by sujan kharel..Heat Exchanger (Shell and tubes) by sujan kharel..
Heat Exchanger (Shell and tubes) by sujan kharel..
 
Boiler calculations
Boiler calculationsBoiler calculations
Boiler calculations
 
Vertical roller mill routine maintenance note
Vertical roller mill routine maintenance noteVertical roller mill routine maintenance note
Vertical roller mill routine maintenance note
 

Viewers also liked

Boiler Water Treatment -
Boiler Water Treatment - Boiler Water Treatment -
DCS overview For Boiler At MPV
DCS overview For Boiler At MPVDCS overview For Boiler At MPV
DCS overview For Boiler At MPV
Phemakorn Khoonsri
 
BOILER PROBLEMS
BOILER PROBLEMSBOILER PROBLEMS
BOILER PROBLEMS
rashmiparbagga1316
 
Water and fire tube boilers
Water and fire tube boilersWater and fire tube boilers
Water and fire tube boilers
Tariq Jamshaid
 
Heat exchanger
Heat exchangerHeat exchanger
Heat exchanger
Ajaykumar Asodariya
 
Cadio munesh
Cadio muneshCadio munesh
Scada in hydropower plant
Scada in  hydropower plantScada in  hydropower plant
Scada in hydropower plant
Indian Institute of Technology Delhi
 
To study of Shaded pole Induction motor
To study of Shaded pole Induction motorTo study of Shaded pole Induction motor
To study of Shaded pole Induction motor
Indian Institute of Technology Delhi
 
Npp
NppNpp
Costumer focus12 06-2010
Costumer focus12 06-2010Costumer focus12 06-2010
Costumer focus12 06-2010
13thidiot
 
Power plant engineering
Power plant engineeringPower plant engineering
Power plant engineering
nareshmeb
 
Hrsg Cleaning
Hrsg CleaningHrsg Cleaning
Hrsg Cleaning
bfsinc
 
Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Lossesguest81e1c7
 
Ash problems
Ash problemsAsh problems
Ash problems
13thidiot
 
Ppt on boilers
Ppt on boilersPpt on boilers
Power plant chemistry corrosion theory and its prevention
Power plant chemistry corrosion theory and its preventionPower plant chemistry corrosion theory and its prevention
Power plant chemistry corrosion theory and its prevention
umar farooq
 
Scada in hydropower plant
Scada  in  hydropower plantScada  in  hydropower plant
Scada in hydropower plant
Indian Institute of Technology Delhi
 
Pollution & control
Pollution & controlPollution & control
Pollution & control
Ajaykumar Asodariya
 
Ahp presentation
Ahp presentationAhp presentation

Viewers also liked (20)

Boiler Water Treatment -
Boiler Water Treatment - Boiler Water Treatment -
Boiler Water Treatment -
 
DCS overview For Boiler At MPV
DCS overview For Boiler At MPVDCS overview For Boiler At MPV
DCS overview For Boiler At MPV
 
BOILER PROBLEMS
BOILER PROBLEMSBOILER PROBLEMS
BOILER PROBLEMS
 
Water and fire tube boilers
Water and fire tube boilersWater and fire tube boilers
Water and fire tube boilers
 
Heat exchanger
Heat exchangerHeat exchanger
Heat exchanger
 
Cadio munesh
Cadio muneshCadio munesh
Cadio munesh
 
Scada in hydropower plant
Scada in  hydropower plantScada in  hydropower plant
Scada in hydropower plant
 
To study of Shaded pole Induction motor
To study of Shaded pole Induction motorTo study of Shaded pole Induction motor
To study of Shaded pole Induction motor
 
Boilers
BoilersBoilers
Boilers
 
Npp
NppNpp
Npp
 
Costumer focus12 06-2010
Costumer focus12 06-2010Costumer focus12 06-2010
Costumer focus12 06-2010
 
Power plant engineering
Power plant engineeringPower plant engineering
Power plant engineering
 
Hrsg Cleaning
Hrsg CleaningHrsg Cleaning
Hrsg Cleaning
 
Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Losses
 
Ash problems
Ash problemsAsh problems
Ash problems
 
Ppt on boilers
Ppt on boilersPpt on boilers
Ppt on boilers
 
Power plant chemistry corrosion theory and its prevention
Power plant chemistry corrosion theory and its preventionPower plant chemistry corrosion theory and its prevention
Power plant chemistry corrosion theory and its prevention
 
Scada in hydropower plant
Scada  in  hydropower plantScada  in  hydropower plant
Scada in hydropower plant
 
Pollution & control
Pollution & controlPollution & control
Pollution & control
 
Ahp presentation
Ahp presentationAhp presentation
Ahp presentation
 

More from Phemakorn Khoonsri

Centrifugal control system At Mitr Phu Khiaw
Centrifugal control system At Mitr Phu KhiawCentrifugal control system At Mitr Phu Khiaw
Centrifugal control system At Mitr Phu KhiawPhemakorn Khoonsri
 
Lightning System AT SKT-B23
Lightning System AT SKT-B23Lightning System AT SKT-B23
Lightning System AT SKT-B23
Phemakorn Khoonsri
 
Lightning System At SKT- B24
Lightning System At SKT- B24Lightning System At SKT- B24
Lightning System At SKT- B24
Phemakorn Khoonsri
 
Grounding System AT SKT- B23
Grounding System AT SKT- B23Grounding System AT SKT- B23
Grounding System AT SKT- B23
Phemakorn Khoonsri
 
Grounding System At SKT-B8
Grounding System At SKT-B8Grounding System At SKT-B8
Grounding System At SKT-B8
Phemakorn Khoonsri
 
ปุ๋ย Hygrow S-L
ปุ๋ย Hygrow S-Lปุ๋ย Hygrow S-L
ปุ๋ย Hygrow S-L
Phemakorn Khoonsri
 
Modify and edit MCC for boiler control At MPV
Modify and edit MCC for boiler control At MPVModify and edit MCC for boiler control At MPV
Modify and edit MCC for boiler control At MPVPhemakorn Khoonsri
 
Repair and modify motor of boiler
Repair and modify motor of boilerRepair and modify motor of boiler
Repair and modify motor of boilerPhemakorn Khoonsri
 
MPV single line and Circuit Diagram
MPV single line and Circuit DiagramMPV single line and Circuit Diagram
MPV single line and Circuit DiagramPhemakorn Khoonsri
 
Uthong electrical and instrument
Uthong electrical and instrumentUthong electrical and instrument
Uthong electrical and instrumentPhemakorn Khoonsri
 
Control desk for boiler at erawan sugar factory
Control desk for boiler at erawan sugar factoryControl desk for boiler at erawan sugar factory
Control desk for boiler at erawan sugar factoryPhemakorn Khoonsri
 
Maintenance electrical and instrument device at rerm udom factory
Maintenance electrical and instrument device at rerm udom factoryMaintenance electrical and instrument device at rerm udom factory
Maintenance electrical and instrument device at rerm udom factoryPhemakorn Khoonsri
 
Mill house maintenance and repair at mpk
Mill house maintenance and repair at mpkMill house maintenance and repair at mpk
Mill house maintenance and repair at mpkPhemakorn Khoonsri
 

More from Phemakorn Khoonsri (16)

Centrifugal control system At Mitr Phu Khiaw
Centrifugal control system At Mitr Phu KhiawCentrifugal control system At Mitr Phu Khiaw
Centrifugal control system At Mitr Phu Khiaw
 
Lightning System AT SKT-B23
Lightning System AT SKT-B23Lightning System AT SKT-B23
Lightning System AT SKT-B23
 
Lightning System At SKT- B24
Lightning System At SKT- B24Lightning System At SKT- B24
Lightning System At SKT- B24
 
Grounding System AT SKT- B23
Grounding System AT SKT- B23Grounding System AT SKT- B23
Grounding System AT SKT- B23
 
Grounding System At SKT-B8
Grounding System At SKT-B8Grounding System At SKT-B8
Grounding System At SKT-B8
 
ปุ๋ย Hygrow S-L
ปุ๋ย Hygrow S-Lปุ๋ย Hygrow S-L
ปุ๋ย Hygrow S-L
 
ESP test record to euroentech
ESP test record to euroentechESP test record to euroentech
ESP test record to euroentech
 
Modify and edit MCC for boiler control At MPV
Modify and edit MCC for boiler control At MPVModify and edit MCC for boiler control At MPV
Modify and edit MCC for boiler control At MPV
 
Repair and modify motor of boiler
Repair and modify motor of boilerRepair and modify motor of boiler
Repair and modify motor of boiler
 
MPV single line and Circuit Diagram
MPV single line and Circuit DiagramMPV single line and Circuit Diagram
MPV single line and Circuit Diagram
 
Uthong electrical and instrument
Uthong electrical and instrumentUthong electrical and instrument
Uthong electrical and instrument
 
Control desk for boiler at erawan sugar factory
Control desk for boiler at erawan sugar factoryControl desk for boiler at erawan sugar factory
Control desk for boiler at erawan sugar factory
 
Maintenance electrical and instrument device at rerm udom factory
Maintenance electrical and instrument device at rerm udom factoryMaintenance electrical and instrument device at rerm udom factory
Maintenance electrical and instrument device at rerm udom factory
 
Mill house maintenance and repair at mpk
Mill house maintenance and repair at mpkMill house maintenance and repair at mpk
Mill house maintenance and repair at mpk
 
Maesod boiler training
Maesod boiler trainingMaesod boiler training
Maesod boiler training
 
Block out overview
Block out overviewBlock out overview
Block out overview
 

Boiler training Maesod

  • 1. BOILER Mae Sod Clean Energy Co., Ltd. IJT
  • 2. BOILER Start Normal state MILL B1 B3 B2 B4 B5 B9 B6 B7 B8 Belt size B1 ขนาด 1000 mm.BW.x33.5 M.L.       11 kw B2 ขนาด 1000 mm.BW.x14.7 M.L.       7.5 kw B3 ขนาด 1000 mm.BW.x214 M.L.      30 kw B4 ขนาด 1000 mm.BW.x14.7 M.L.      7.5 kw B5 ขนาด 1200 mm.BW.x43 M.L.        22 kw B6 ขนาด 900 mm.BW.x38 M.L.           11 kw B7 ขนาด 900 mm.Bw.x73 M.L.            15 kw B8 ขนาด 1500 mm.BW.x9 M.L.            5.5 kw B9 ขนาด 900 mm.BW.x89 M.L.          11 kw
  • 3. INTER LOCK BELT CONVEYOR NO. START Normal state FORM RUNING NO. FORM RUNING NO. B.1 OFF ▬ ON 9 B.2 ON 2 ON 2 B.3 ON 1 ON 1 B.4 ON 4 ON 4 B.5 ON 3 ON 3 B.6 ON 5 OFF ▬ B.7 ON 6 OFF ▬ B.8 ON 7 OFF ▬ B.9 ON 8 ON 8
  • 4.  
  • 5. FURNACE DRUM STOKER การไหลของ เชื้อเพลิง , ลม , แก๊สและขี้เถ้า IJT Boiler Steam Boiler Cap. : 95 TPH Pres. : 60 Bar Temp. : 500 °C F.W.P. : 160°C Bag. feed : 4 set Bag. Ext. : 13000kg/hr
  • 6. Boiler สำหรับโรงไฟฟ้า ทำหน้าที่ 2 อย่างคือ เผาไหม้เชื้อเพลิงเพื่อสร้างความร้อน และ ใช้ความร้อนนั้นเปลี่ยนน้ำให้เป็นไอน้ำ
  • 7. วงจรของ Boiler โดยทั่วไปจะแบ่งออกเป็น 4 ส่วนใหญ่ๆ คือ Air & Gas system Water & Steam system Fuel Handling system Ash Handling system
  • 8. superheat economizer 200 ๐ C 160 ๐ C 800 ๐ C
  • 9.  
  • 10. COMBUSTION AIR SYSTEM การเผาไหม้ คือปฏิกิริยาทางเคมีระหว่างเชื้อเพลิงกับ Oxygen เพื่อที่จะให้เกิดการเผาไหม้ จะต้องมีส่วนประกอบทั้ง 4 อย่างคือ Oxygen , Fuel , Heat( ความร้อน ) และ Chemical reaction( ปฏิกิริยาเคมี ) เมื่อใดก็ตามที่มีทั้ง 4 อย่างดังกล่าว การเผาไหม้จะเริ่มต้นและสามารถที่จะดำเนินต่อไปได้เองถ้าสิ่งหนึ่งสิ่งใดขาดหายไปการเผาไหม้ก็จะหยุดลง
  • 11. เชื้อเพลิง คือสารที่เผาไหม้ได้และใช้ผลิตพลังงานความร้อนโดยการเผาไหม้ ในที่นี้ เชื้อเพลิงที่ใช้ในการเผาไหม้คือ กากอ้อย Bagasse analysis Hydrogen : 3.04 % Carbon : 23.24 % Oxygen : 22.08 % Moisture : 50.0 % HHV : 2272Kcal / Kg
  • 12. เพื่อให้การเผาไหม้นั้นจะสมบูรณ์ Turbulence เพื่อผสมเชื้อเพลิงกับอากาศอย่างทั่วถึง และ Time ระยะเวลาในการเผาไหม้
  • 13. ในขบวนของการที่จะเผาไหม้ เชื้อเพลิงกากอ้อย ต้องผสมกับออกซิเจน อย่างทั่วถึง เมื่อเผาไหม้แล้วก็ให้ความร้อนออกมา ทุกๆองค์ประกอบในเชื้อเพลิงจะผสมกับอ๊อกซิเจน แต่จะมีเพียง 3 องค์ประกอบเท่านั้นที่เผาไหม้ คือ Carbon Hydrogen Sulphur
  • 14. Carbon มีประโยชน์ในการเผาไหม้มากที่สุด ปริมาณมากที่สุดและเผาไหม้ได้ง่าย Sulphur จะมีปัญหามากที่สุด เพราะก่อให้เกิดมลพิษ แต่กากอ้อยมีเปอร์เซ็นต์ ของ sulphur น้อยมาก Oxygen ที่มีอยู่ในเชื้อเพลิง ไม่เพียงพอที่ทำให้ก่อประโยชน์ใดๆได้ Nitrogen ซึ่งโดยปกติแล้วไม่ติดไฟ แต่จะสามารถรวมกับองค์ประกอบอื่นในระหว่าง การเผาไหม้ เกิดเป็นมลพิษขึ้นมาได้และต้องควบคุม Ash เป็นคำซึ่งใช้อธิบายของแข็ง ไม่ติดไฟ ทำให้เกิดปัญหา หลายประการ - เป็นส่วนประกอบของเชื้อเพลิงที่ต้องสูญไปโดยเปล่าประโยชน์ - เป็นสาเหตุให้เกิดการกัดกร่อน (Corrosion) - การสึกกร่อน (Erosion) ซึ่งสามารถนำไปสู่การแตกหัก เสียหาย - และประการสุดท้าย ปัญหาที่จะต้องกำจัด Ash
  • 15.  
  • 16.  
  • 18. IJT 60kg/cm 2 ค่าควบคุมมาตรฐานคุณภาพน้ำในหม้อไอน้ำ ณ ความดันไอน้ำต่างกัน Boiler water Quality Recommendation At Increasing Pressure ( All value,except ; given in ppm ) in Sugar Industry             Intermediate             Low to 250 psi 250 -300 psi 300 - 450 psi   0 - 15 kg/cm 2 15 - 20 kg/cm 2 2 0 - 30 kg/cm 2 Total hardness, as Ca CO 3 0 0 0 Total Alkalinty, as Ca CO 3 700 700 700 Hydroxide, as Ca CO 3 150 - 300 150 - 300 130 Silica, as SiO 2 100 - 133 50 - 67 50 - 67 Dissolved Oxygen 0.015 0.015 0.015 Total Dissolved Solid < 2,500 < 2,000 < 1,500 Suspended Solid < 600 < 300 < 200 Conductivity, micro - mho / cm < 3,500 < 2,850 < 2,150 PH 11 - 11.8 11 - 11.5 10.5 - 11.5 Oil 1.0 1.0 1.0 Sodium Sulphite ; as Na 2 SO 3 30 - 60 30 - 40 20 - 30 Phosphate ; as PO 4 3- 20 - 40 20 - 40 5. - 15 Hydrazine ; as N 2 H 4 0.1 - 0.3 0.1 - 0.4 0.1 - 0.5                     จากหนังสือ การประหยัดพลังงานความร้อน     ปี 2531 บทที่ 5 เรื่องการปรับสภาพน้ำ     สำนักงานพลังงานแห่งชาติ Nil 2.5 100 200 9.5-10.5 20
  • 19. WATER TREATMENT & BOILER FEED WATER RAW WATER FILTERING FILTERED WATER SOFTENING RO DEMINERALIZATION THERMAL DEAERATION MAKE - UP WATER
  • 20. CONDENSATE POLISHING ADDITTIVE INJECTION THERMAL DEAERATION FEED WATER BOILER WATER STEAM CONDENSATE BLOW - DOWN 160 °C IJT
  • 21. การหมุนเวียน ( Circulation ) ใน boiler เป็นสิ่งจำเป็นด้วยเหตุผล 2 ประการ ประการแรกคือ การตระเตรียมปริมาณน้ำที่ supply ให้พอดีในการเปลี่ยนน้ำนั้น ให้กลายเป็นไอน้ำ ประการที่สองคือ น้ำนั้นจะต้องพาเอาความร้อนของ boiler furnace ออกไป จาก waterwalls ถ้าการไหลของน้ำลดลงหรือถูกตัดออกไป ท่อน้ำก็จะ overheat และแตกในที่สุด Water Flow Path
  • 22. ความร้อนที่ได้จากการเผาไหม้ จะถูกถ่ายเทไปให้กับ steam และน้ำ โดยผ่านท่อที่ประกอบเป็นผนังเตา ท่อผนังเตาทำด้วย carbon steel ทนอุณหภูมิสูงสุดได้ประมาณ 482 ° c อุณหภูมิของ steam/water mixture ภายในท่อจะอยู่ที่ประมาณ 260 ° c อุณหภูมิของ superheater steam ภายในท่อจะมีอุณหภูมิประมาณ 500 ° c ขณะที่ gas นอกท่ออาจสูงถึง >1,000 ° c เนื้อโลหะของ superheater จะทนได้ประมาณ 600 ° c โดยมี น้ำและ steam flow อยู่ในท่อเป็นตัวรักษาอุณหภูมิไม่ให้เกินลิมิต ( Limit ) ที่มันทนได้
  • 23. ขณะทำการ Start-up ใหม่ๆ ปริมาณ Steam Flow จากการเปิด vent และ drain superheat จะยังมีน้อยมาก เมื่อน้ำที่มีอยู่ในท่อ superheat หมดไป อุณหภูมิจะเพิ่มขึ้นทันทีโดยจะสูงเท่ากับอุณหภูมิของ superheater steam จึงต้องปรับอัตราของ firing ควบคุมไม่ให้ furnace gas temp . เกิน 537 °c ก่อนที่กังหันจะเริ่มรับ load และมี steam flow ผ่านท่อ superheater มากพอ เพื่อให้ superheater metal temperature ต่ำกว่าค่าสูงสุดที่โลหะทนได้ ( ประมาณ 600 ° c ) ถ้า firing rate หรืออัตราการป้อนเชื้อเพลิงเร็วไป จะทำให้ superheater metal temperature สูงเกินค่าที่โลหะทนได้ เพราะความร้อนที่เพิ่มขึ้น เร็วกว่าค่าความร้อนที่ steam สามารถรับเอาไว้ หรือท่อโลหะคายความร้อนให้ steam ไม่ทันนั่นเอง
  • 25.  
  • 26. การไหลเวียน (Circulation) ความร้อนจำนวนมหาศาลที่ผนังเตา และ superheater รับเข้าไว้ มีเพียง fluid ( น้ำ หรือไอน้ำ ) ที่อยู่ภายในท่อเท่านั้นที่เป็นตัวดึงความร้อนนี้ ออกไปและดึงอุณหภูมิของท่อไว้ให้ต่ำกว่า safe limit ไม่ให้ท่อเสียหาย การไหลเวียนอย่างต่อเนื่องของ fluid จึงป้องกันไม่ให้ท่อร้อนจนเกินไป (overheat) การไหลเวียนของน้ำผ่าน water walls จะแบ่งออกเป็น 3 แบบ Natural circulation ไหลเวียนตามธรรมชาติ Forced circulation ไหลเวียนตามธรรมชาติ โดยมี circulating pump ช่วยการไหลเวียน Once through ไหลผ่านรวดเดียว
  • 29. จะต้องควบคุม acidity ของน้ำที่ใช้ด้วย ( ค่าความเป็นกรด ) acidity เราวัดด้วย pH ค่า pH = 7 หมายถึง น้ำมีค่าเป็นกลาง ถ้า pH ต่ำกว่า 7 น้ำมีฤทธิ์เป็นกรด ถ้า pH สูงกว่า 7 น้ำมีฤทธิ์เป็นด่าง เพื่อไม่ให้หม้อน้ำและท่อเกิดการกัดกร่อน น้ำที่ไหลภายในท่อจะต้องไม่มีฤทธิ์เป็นกรด
  • 30. Acid Attcak ถ้า pH ต่ำกว่า 7 น้ำมีฤทธิ์เป็นกรด จะสามารถกัดเนื้อเหล็กออกจากผนังท่อได้ Caustic Attack ถ้า pH สูงกว่า 7 มากๆ น้ำมีฤทธิ์เป็นด่าง จะทำให้เหล็กกร่อนได้เช่นเดียวกัน การป้องกัน corrosion เราจะต้องคุม ค่า pH และกำจัดแก๊สที่เจือปนในน้ำ
  • 31. scale ที่เกาะภายในท่อจะทำหน้าที่คล้ายฉนวน ทำให้ท่อเกิด overheat และแตกในที่สุด Scale เกิดจากสารอยู่ในน้ำจะประกอบด้วย สารแขวนลอย (suspended solids) สารละลาย (dissolved solids) สารแขวนลอย คือตะกอน , โคลน , สิ่งสกปรกที่มีอยู่ในน้ำการสกัดออกโดยใช้ clarifier สารละลาย คือเกลือแร่ที่น้ำได้ละลายไว้ ซึ่งพบเสมอได้แก่ silica ( Sio2- ซิลิกอนไดออกไซด์ ) เป็นสารประกอบจำพวก เหล็ก , แคลเซียม และ แมกนีเซียม
  • 32. หม้อน้ำ เมื่อไอน้ำเกิดขึ้นและถูกส่งออกจาก steam drum แล้วสิ่งสกปรกจะตกค้างอยู่ภายในหม้อน้ำและเพิ่มความเข้มข้นขึ้น ( คือ เกลือกระด้าง ได้แก่ แคลเซียม และแมกนีเซียม ) ถ้าปล่อยทิ้งไว้นานเข้าจะกลายเป็นตะกรัน เกาะตามผนังภายในท่อ และ steam drum ผล ประสิทธิภาพลดลง เพราะการถ่ายเทความร้อนได้ยากขึ้น ผลเสียหายร้ายแรงที่เกิดจากการเกิดตะกรัน คือท่อแตก เราควบคุม concentration ( ความเข้มข้น ) ได้โดยวิธี continuous blowdown
  • 33. การเติมสาร ฟอสเฟต ( phosphate ) ลงไปในหม้อน้ำ จะช่วยให้ลดความกระด้างอันเนื่องมาจากแคลเซี่ยมและแมกนีเซี่ยมในหม้อน้ำได้ ฟอสเฟต จะจับแคลเซี่ยมและแมกนีเซี่ยม ในน้ำให้รวมตัวกันเป็น Sludge ( ขี้โคลน , ตะกอน ) จึงป้องกันการเกิด hard scale ( ตะกรันแข็ง ) การทำ continuous blowdown จะกำจัดสารเคมีบางส่วนที่จำเป็นสำหรับหม้อน้ำทิ้งไปพร้อมๆกับสสารอื่นๆ ดังนั้นจึงจำเป็นต้องเติมสารเคมีชดเชยส่วนที่สูญเสียไป
  • 34. ทุกๆวันพนักงานเคมีฯ จะต้องนำน้ำในหม้อน้ำไปตรวจวิเคราะห์เพื่อหาค่า silica , phosphate , total solids ( ปริมาณสารของแข็งทั้งหมดที่มีอยู่ในน้ำ ) และ pH