AIR PREHEATER
INTRODUCTION:
HEAT EXCHANGER
HEAT TRANSFER FROM FLUE GAS TO AIR
HEAT REJECTED TO ATMOSPHERE REDUCED
INCREASE BOILER EFFICIENCY BY STABILITY OF COMBUSTION
WITH HELP OF HOT AIR.
HOT AIR USED FOR DRYING THE COAL AS WELL AS FOR
TRANSPORTING.
FOR EVERY 20°C DROP IN FLUE GAS EXIT TEMPERATURE THE
BOILER EFFICIENCY INCREASE BY ABOUT 1%.
10% IMPROVEMENT IN BOILER EFFICIENCY WHEN
COMPARED TO AN IDENTICAL UNIT WITHOUT AN APH.
Why APH in Boiler System
• APH - Tail ender
• APH & Economizer are heat recovery
• surface
• Designers always look at this in pair
• Economizer - self limiting characteristics
• Can steam if not properly sized
• Minimum 25 – 30 deg C Eco out F W
& saturation temperature
• APH can be sized for any requirement
• APH has ability to absorb changes
TYPES OF AIR PREHEATERS:
AIR PREHEATERS CAN BE CLASSIFIED AS RECUPERATIVE AND
REGENERATIVE TYPES BASED ON THEIR OPERATING PRINCIPLE.
IN RECUPERATIVE TYPE HEATING MEDIUM I.E. FLUE GAS IS ON ONE
SIDE AND AIR IS ON THE OTHER SIDE OF TUBE OR PLATE AND THE
HEAT TRANSFER IS BY CONDUCTION THROUGH THE MATERIAL
WHICH SEPARATES THE MEDIA. THESE ARE OF STATIC
CONSTRUCTION AND HENCE THERE IS ONLY NOMINAL LEAKAGE
THROUGH EXPANSION.
IN REGENERATIVE TYPE THE HEATING MEDIUM FLOWS THROUGH A
CLOSELY PACKED MATRIX TO RAISE ITS TEMPERATURE AND THEN
AIR IS PASSED THROUGH THE MATRIX TO PICK-UP THE HEAT.
EITHER THE MATRIX OR THE HOODS ARE ROTATED TO ACHIEVE
THIS AND HENCE THERE IS SLIGHT LEAKAGE THROUGH SEALING
ARRANGEMENTS AT THE MOVING SURFACES.
TYPES
RECUPERATIVE RE-GENERATIVE
STATIC CONSTRUCTION ROTARY BY CONSTRUCTION
TUBULAR TYPE
PLATE TYPE
SCAPH
TRI-SECTOR
BI-SECTOR
Quad-Sector
ROTHEMUHLE
MATRIX ELEMENT STATIONARY
LJUNGSTROM TYPE
MATRIX ELEMENT ROTATING
HEAT PIPE or THERMOSYPHONE
TUBULAR AIR PREHEATER (RECUPERATIVE):
•LARGE NUMBER OF STEEL TUBES OF 40 TO 65 MM DIA.
•EITHER WELDED OR EXPANDED INTO THE TUBE PLATES.
•EITHER GAS OR AIR FLOW THROUGH THE TUBE.
•GAS THROUGH THE TUBE NORMALLY REQUIRES HIGHER SIZE TUBE
AND VERTICAL FLOW TO REDUCE FOULING.
•SINGLE OR MORE PASSES ON THE GAS SIDE AND MULTIPASS CROSS
FLOW ON THE AIR SIDE USUALLY FITS IN WITH THE OVERALL PLANT
DESIGN.
•THE PORTION OF AIRHEATER AT LOW TEMPERATURE ZONE IS
DESIGNED NORMALLY WITH A SHORTER TUBE LENGTH SO AS TO
FACILITATE MAINTENANCE OF SURFACES DUE TO CORROSION AND
FOULING.
PLATE TYPE AIR PREHEATER (RECUPERATIVE):
•THESE COMPRISE OF PARALLEL PLATES.
• WHICH PROVIDE ALTERNATE PASSAGE FOR GAS AND AIR.
•THIS TYPE IS SIMPLE AND COMPACT COMPARED TO THAT OF TUBULAR
TYPE.
•THE NARROW PASSES BETWEEN PLATES MAKE THE CLEANING
TEDIOUS BUT WITH SHOT CLEANING METHOD IT IS IMPROVED.
•REPLACEMENT IS A MAJOR TASK.
LJUNGSTROM REGENERATIVE AIR - HEATER
•THE HEAT TRANSFER ELEMENTS ARE ROTATED AT A CONSTANT
SPEED AND THEY PASS ALTERNATELY THROUGH GAS AND AIR
PASSES.
•THE AXIS OF ROTATION MAY BE HORIZONTAL OR VERTICAL.
•THE DRIVE IS NORMALLY ELECTRICAL OPERATED THROUGH
REDUCTION GEAR WITH COMPRESSED AIR MOTOR AS STAND-BY.
•THE PLATES FORMING THE ELEMENTS (MATRIX) MAY BE VARIED IN
SPACING AND THICKNESS.
•COLD ENDS ARE MADE OF SPECIAL CORROSION RESISTANCE ALLOY
SUCH AS CORTEN OR ENAMELED TO ACHIEVE CORROSION
RESISTANCE.
•THIS TYPE IS VERY COMPACT AND LENDS EASILY FOR DUCTING
ARRANGEMENT EFFECTIVE CLEANING OF HEAT-TRANSFER SURFACE
BY SOOT BLOWING IS POSSIBLE.
• THE BASIC COMPONENT OF THE CONTINUOUSLY ROTATING
CYLINDER, CALLED THE ROTOR, THAT IS PACKED WITH THOUSANDS OF
SQUARE FEET OF SPECIALLY FORMED SHEETS OF HEAT TRANSFER
SURFACES.
• AS THE ROTOR REVOLVES, WASTE HEAT IS ABSORBED FROM THE
HOT EXHAUST GAS PASSING THROUGH ONE HALF OF THE SURFACE.
• THIS ACCUMULATED HEAT IS RELEASED TO THE INCOMING AIR AS
THE SAME SURFACES PASS THROUGH THE OTHER HALF OF THE
STRUCTURE. THE HEAT TRANSFER CYCLE IS CONTINUOUS AS THE
SURFACES ARE ALTERNATELY EXPOS ED TO THE OUTGOING GAS AND
INCOMING AIR STREAMS.
• FUEL SAVINGS WITH THE LJUNGSTRÖM AIR PREHEATER ARE
ABOUT 1-1½% FOR EVERY 4.4°C TO 10°C INCREASE IN COMBUSTION
AIR TEMPERATURE, DEPENDING ON THE APPLICATION.
•THEIR SIMPLIFIED DESIGN AND OPERATING INTEGRITY ASSURE
CONTINUOUS RELIABLE SERVICE THROUGHOUT THE LIFE OF THE
PLANT.
Size Type Rotor Dia (Meters) Heat Duty(M.K.Cals/Hr)
7 - 16.5 K 1.2 - 3.0 2.5 - 60
17 - 18.5 S 3.2 - 3.8 50 - 70
19 - 24 R 4.2 - 6.6 70 - 200
24.5 - 36 LARGE 6.9 - 20.0 > 200
Range of RAPH
Designation of RAPH
27 VI M T 2000
Size number
Vertical Shaft; Inverted gas Flow
Modular Rotor
Trisector
Element depth in
mm
BI-SECTOR TRI-SECTOR
BI-SECTOR
THE MAJORITY OF LJUNGSTRÖM
AIR PREHEATERS SUPPLIED ARE IN
THE BI- SECTOR DESIGN. THESE
HEATERS HAVE TWO BASIC
STREAMS, ONE OF GAS AND ONE OF
AIR.
TRI-SECTOR
TRI-SECTOR AIR PREHEATER PERMITS A SINGLE HEAT EXCHANGER
TO PERFORM TWO FUNCTIONS: COAL DRYING AND COMBUSTION AIR
HEATING.
THE DESIGN HAS THREE SECTORS - ONE
FOR THE FLUE GAS, ONE FOR THE PRIMARY
AIR THAT DRIES THE COAL IN THE
PULVERIZER, AND ONE FOR SECONDARY
AIR THAT GOES TO THE BOILER FOR
COMBUSTION
• QUADSECTOR
•THE QUAD-SECTOR IS WITH FOUR
FLOW STREAMS THROUGH THE
ROTOR.
•THE FOUR SECTORS COMPROMISE ONE GAS AND
ONE PRIMARY AIR AS IN THE TRI- SECTOR, BUT
THERE ARE TWO SEPARATE SECONDARY AIR
SECTORS.
•THE DESIGN HAS THE PRIMARY AIR SECTOR’ FLANKED' ON EITHER
SIDE BY SECONDARY AIR, AND THIS HAS A BENEFIT ON THE TOTAL AIR-
TO-GAS LEAKAGE OF THE UNIT.
AIR HEATER –(SCHEMATIC)
RADIAL SEAL
AXIAL
SEAL
BYPASS SEAL
COLD END
HOT END
HOT INTERMEDIATE
GUIDE BEARING
SUPPORT BEARING
ROTOR:
The rotor is the heart of the equipment radially divided open ended cylinder which
contains the heating surface elements. The center shaft of the rotor is called the
post. Diaphragm plates extend out ward from the post dividing the rotor into 12 or 24
sectors which are further divided to form compartments into which the element
baskets are packed-A pin rack is located around the outside of the rotor to allow it to
be rotated by the drive mechanism.
HEATING ELEMENTS:
They are packed in a reversible containers called baskets, are placed in
rotor in three tiers: - Hot, Intermediate and Cold.
The notches are used for maintaining the spaces between the elements
and minimizing the pressure drop across the air preheater.
• HOT END BASKETS & HOT INTERMEDIATE : -
Hot End is the first layer & Hot Intermediate is second layer of heating element
packing from hot end side. The elements are usually made from 24 gauge / 22
gauge(0.5 – 0.8MM) open hearth steel (IS 513 Gr. DD). They are having a
profile called “Double Undulation. The notches run parallel with the rotor axis
and provide the correct spacing of sheets and the undulations run at 60° to the
notches to impart turbulence. Open-channel element, where the notches, which
provide the required plate spacing, rest on a series of point contacts on the
adjacent sheet. Flow can move across the element pair because there are
openings between the two sheets along the flow length between point contacts.
COLD END BASKETS
The elements are made of 18 gauge / 22 gauge carton steel. Enameled elements
are also used in severe corrosive conditions like for more percentage of sulphur in
fuel or for low gas duct temperature. All the heating surface elements are packed
into reversible containers called baskets to facilitate easy removal and handling.
Cold end baskets are arranged for removal through the basket removal door in the
housing.
A closed element profile is the notched flat 6-mm element (NF6), the element pair
is formed by a series of notches that rest on an adjacent flat sheet with contact
along the total flow length. They provide the necessary spacing and form discrete
individual flow channels of fixed cross-sectional area along the flow length or
element depth. There is no flow communication from one channel to the adjacent
one.
AIR LEAKAGE
• Leakage of the higher pressure air to the lower pressure flue gas
through the clearances between the rotor seals and the sector plates.
• Air to gas leakage can be increase with time, to more than twice the
immediate post overhaul level.
• Can be increase with increase in differential pressure of
two fluids
• Leakage paths for a tri-sector APH are more complex, compared
to a bi-sector .
• In a tri-sector , primary air leaks into the flue gas and secondary
air streams, while SA leaks into the flue gas stream.
• Leakage occurs both on the cold end (CE) and hot end (HE).
• Due to large difference in pressure between the PA and SA
streams, as well as the PA and flue gas streams, leakage in a
tri-sector APH is higher than in a bi-sector APH.
• Air leakage has the largest single effect on APH performance.
• Two penalties to boiler performance occur with excessive radial seal leakage.
1.Thermal losses associated with the leakage air cooling the APH.
2. Additional auxiliary horsepower consumed by the fans for pushing more flow.
TYPE OF AIR LEAKAGE
A. ENTRAINED LEAKAGE :
B. DIRECT LEAKAGE :
• THIS IS MAINLY ENTRAPED AIR IN BETWEEN THE HEATING ELEMENTS
We = γ . v . rpm. 60
γ = Sp. Wt of air in Kg/m3
v = Volume of Rotor air space
• THIS IS MAINLY DUE TO DIFFERENTIAL PRESURE OF TWO FLUID
• INCREASE OF SEAL CLEARANCE AT HOT CONDITION
• EROSION OF SEALS
• IMPROPER SEAL SETTING
Wd = α ∗ A *√(2g * γ * ∆ P)
α= Coeff. Of flow rate (0.6 – 0.7)
g= Acceleration due to gravity
A= Gap area at hot condition (m2
)
∆P= Diff. pr. Of two fluids
γ = Sp. Wt of air in Kg/m3
Variable factors are Α & ∆P
* Hence amount of entrained Leakage is independent of operating and maintenance condition
Circumferential
bypass seal leakage
into the warm airflow
Peripheral bypass
seal leakage into the
gas path
Circumferential
bypass seal
leakage into the
cold gas flow.
Hot radial
seal leakage
Cold radial
seal leakage
VARIOUS LEAKAGE PATHS THROUGH THE APH
It is noted that nearly
80-85% leakage is
from Radial Seal
10-15% through By-
Pass Seal
5-10% through Axial
LEAKAGE PATH
THERMAL TURNDOWN
When the APH rotor is heated from a
cold condition (blue), thermal
expansion (yellow) can cause the rotor
to droop or “turn down” up to 3 inches
on the periphery. Knowing the amount
of turndown is important when
presetting the seal position before
operation, because seal positions will
change as the rotor warms to its
operating temperature.
• SEALING SYSTEM COMPRISES THE
FOLLOWING:
– RADIAL SECTOR & AXIAL SEALING PLATE
– RADIAL, CIRCUMFRENCIAL & AXIAL SEALS
– ROTOR POST SEALS
– INBOARD & OUTBOARD STATIC SEALS
SEALING SYSTEM
SEALING SYSTEM: -
Usually air leaks into the gas stream due to static pressure differential. This leakage
air decrease the air leaving temperature. Various arrangements to reduce the
leakage are as follows.
The sealing arrangement consists of Radial, Axial, Bypass, Axial Seal Plate to
Sector Plate, Static, Rotor Post Seals and Mechanical Sealing Plates designed to
minimize leakage between the gas and air streams of the pre-heater.
THE RADIAL SEALS are located along the edges of the diaphragm plates and bear
against the sector plates, housed under centre sections.
THE AXIAL SEALS are located axially in line with the outer edge of diaphragm
plates and bear against the axial seal plates, mounted in the housing pedestals.
THE BYPASS SEALS are located on the housing around the periphery of the rotor
and bear against the T-bar attached to the periphery of the rotor.
THE AXIAL PLATE TO SECTOR PLATE SEALS are attached to the axial seal plats
and bear against the sector plates.
THE STATIC SEALS are fixed under the centre sections and housing pedestals and
bear against sector plates and axial seal plates respectively.
THE ROTOR POST SEALS are attached to the ends of the rotor posts and bears
against the sector plates.
SEALING SYSTEM: -
– SINGLE LEAF TYPE
• Only one sealing strip passing under sector plate & axial seal plate
any one time.
• Adjusted with no gap due to sharp edge & bend.
• 6% reduction in radial seal leakage than channel type.
RADIAL SEALS
AXIAL & BY-PASS SEALS
Gaps are observed around the Baskets and with Diaphragm/Stay
plates. This will by-pass the flue gas: thereby loosing the efficiency of
the boiler. This is revealed by the high flue gas outlet temperature.
The newly developed erosion resistant ‘Basket Bypass Seal’, which will
permanently close the gaps till the next replacement of the baskets.
This will result in lower flue gas outlet temperature, which will improve
the efficiency of the Boiler.
BASKET BYPASS SEAL
CIRCUMFERENTIAL SEALS DEFLECTORS
Ideas for deflector Plates and Clay Cloth seals which cater
for thermal load dependant rotor position fluctuations have
been devised previously.
EROSION
Erosion caused by fly ash has resulted in the rapid loss of a heat exchange
element as well as damage to perimeter seals, radial seals, and rotor
diaphragms. Two other factors with regard to erosion are actually more
important than ash content: abrasiveness and ash velocity.
The abrasiveness of fly ash increases as the amount of silica and alumina
increases.
Ash velocity is as much as three times more important than ash content or
abrasiveness when it comes to determining the rate of erosion. One way to defeat
high ash velocity is to increase the fineness of the coal particles leaving the
pulverizers and balancing the coal and air flows to each of the burners.
CORROSION, PLUGGING AND FOULING
A lower flow rate of combustion air results in a lower furnace excess air
(excess O2) level, increased CO emissions, increased levels of unburned
fuel in fly ash, higher furnace exit gas temperature, increased slagging
and fouling rates, and higher net unit heat rate.
Cold End Heating elements were seriously affected by corrosion
mainly in oil fired boilers. Corrosion causes due to formation of
sulphuric acid.
To avoid corrosion:
a. Complete combustion of fuel oil to be ensured.
b. Soot blowing at regular intervals to be done.
c. Maintaining minimum cold end average temperature.
d. Heating elements to be dried properly after water washing.
e. Oil quality to be ensured.
FOULING, PLUGGING AND CORROSION:
? Deposits are initiated by condensation of acid or moisture from flue gas on
metal surface operating at temperature below dew point i.e. mainly at the cold
end, where, as a result, most fouling and corrosion occur.
? Degree of fouling depends on heating element metal surface.
? As coal contains less sulphur, corrosion is not normally as much a problem
as fouling and hence lower exit gas temperature to a level of 120 C is
permissible.
? But in the case of oil firing, the corrosion and plugging due to corrosive
products of combustion are very common.
? The gas outlet temperature and/or air inlet temperature has to be raised to
restrict the corrosion to the permissible level.
? Operating the oil fired boiler at very low excess air reduces the acid formation
and hence corrosion.
? During starting and at low loads the flue gas exit temperature falls to a low
value that will lead to corrosion.
One or some of the following method is used to combat the problem:
1. Use of low sulphur oil during the above condition.
2. Air inlet temperature is increased mostly by steam air heating to maintain the
recommended cold end average temperature for the installation.
2. Corrosion resistant alloys like corten steel can be used for cold end.
3. Easily and economically replaceable cold end portion of airheater without much
outage period.
4. Effective on-load blowing of airheaters with superheated steam as moisture in
steam accelerates fouling and corrosion.
APH THERMAL EFFICENCY
• Gas side efficiency ‘η’gas.
• Air side efficiency ‘η’air.
• X-Ratio.
IF: -
Tgi = APH Gas inlet temperature.
Tgo = APH Gas outlet temperature.
Tai = APH air inlet temperature.
Tao = APH air outlet temperature
Tgo (nl) = APH Gas outlet temperature at no seal leakage.
APH GAS SIDE EFFICIENCY
Flue gas inlet temp. – Flue gas outlet temp. at no seal leakage
=
Flue gas inlet temp. – Air inlet temp.
Tgi – Tgo (nl)
=
Tgi – Tai
TgO (nl) = Corrected gas temp. for no seal leakage
Al X Cpa (Tgo – Tai)
= + Tgo
100 X Cpg
AL = % Seal leakage on wt.
O2 out – O2 in
= X 100 X (0.9 for coal)
21 – O2 o
Cpa = Mean specific Heat between Tgi and Tgo
Cpg = Mean specific Heat between Tgo and Tgonl
Cpa / Cpg = 0.95 for Coal
Tao - Tai
ηai = X 100%
Tgi - Tai
Tgi – Tgo (nl) ηgas
X-Ratio = =
Tgi – Tai ηair
20°C rise in flue gas exist temperature there is decrease in boiler η 1% i.e. =
loss of 26 Kcal approx.
DRIVE ARRANGEMENT : -
The drive mechanism consists of:
• Two electric motor connected to a gear reduction unit through
overrunning clutch and fluid coupling driving a pinion gear.
• The pinion gear meshes with a pin rack on the rotor which allows the
rotor to rotate at a low speed.
• Provision of Air Motor is also given for any failure of electric drive units.
Rotor Drive Assembly (Down Shaft Design)
1. High Speed Coupling
2. Drive Motor (Main)
3. Pin Rack
4. Rotor Housing.
5. Support Bracket
6. Pinion
7. Pinion Cover
8. Speed Reducer
9. Air Motor (Auxiliary)
07. Motor – TEFC: 11 KW, 3
Phase,
50 Hz, 415 V,
1450 RPM,
05-06 Speed Reducer : Type – I
Japan,
Rissowai
09. Coupling : 11.50 FCU
(Pembril)
08. Air Motor = Chiago Pneumatic
Air
Motor RSM 400
10. Coupling = Bibby 124 A
THANK YOUTHANK YOU

More Related Content

What's hot

Performance calculation for feed water heater
Performance calculation  for feed water heaterPerformance calculation  for feed water heater
Performance calculation for feed water heaterSHIVAJI CHOUDHURY
 
Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Hammad Akber
 
Principle of operation bowl mill
Principle of operation bowl millPrinciple of operation bowl mill
Principle of operation bowl millDevidutta Panda
 
Construction of 500 MW Steam Boiler
Construction of 500 MW Steam BoilerConstruction of 500 MW Steam Boiler
Construction of 500 MW Steam BoilerVaibhav Paydelwar
 
Boiler Loss of Flame Protection- MFT
Boiler Loss of Flame Protection- MFTBoiler Loss of Flame Protection- MFT
Boiler Loss of Flame Protection- MFTTahoor Alam Khan
 
Handling of turbine during emergencies
Handling of turbine during emergenciesHandling of turbine during emergencies
Handling of turbine during emergenciesManohar Tatwawadi
 
TPS Coal Mills and Fan Performance
TPS Coal Mills and Fan PerformanceTPS Coal Mills and Fan Performance
TPS Coal Mills and Fan PerformanceManohar Tatwawadi
 
Hp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbinesHp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbinesBoben Anto Chemmannoor
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plantSHIVAJI CHOUDHURY
 
Energy adudit methodology for boiler
Energy adudit methodology for boilerEnergy adudit methodology for boiler
Energy adudit methodology for boilerKongkiert Tankayura
 
Turbine Stress Control Logic, Calculation & Working
Turbine Stress Control Logic, Calculation & WorkingTurbine Stress Control Logic, Calculation & Working
Turbine Stress Control Logic, Calculation & WorkingTahoor Alam Khan
 
POWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINEPOWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINEManohar Tatwawadi
 
Pulverized coal fired boiler startup procedure
Pulverized coal fired boiler startup procedurePulverized coal fired boiler startup procedure
Pulverized coal fired boiler startup procedureAshvani Shukla
 
Coal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plantsCoal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plantsSHIVAJI CHOUDHURY
 
The Coal mill performance monitoring
The Coal mill performance monitoringThe Coal mill performance monitoring
The Coal mill performance monitoringManohar Tatwawadi
 
Super critical boiler
Super critical boilerSuper critical boiler
Super critical boilerMilap Desai
 
HP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam TurbineHP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam TurbineRAVI PAL SINGH
 

What's hot (20)

Performance calculation for feed water heater
Performance calculation  for feed water heaterPerformance calculation  for feed water heater
Performance calculation for feed water heater
 
Heat rate of coal fired power plant
Heat rate of coal fired power plantHeat rate of coal fired power plant
Heat rate of coal fired power plant
 
Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)
 
Principle of operation bowl mill
Principle of operation bowl millPrinciple of operation bowl mill
Principle of operation bowl mill
 
Construction of 500 MW Steam Boiler
Construction of 500 MW Steam BoilerConstruction of 500 MW Steam Boiler
Construction of 500 MW Steam Boiler
 
Boiler Loss of Flame Protection- MFT
Boiler Loss of Flame Protection- MFTBoiler Loss of Flame Protection- MFT
Boiler Loss of Flame Protection- MFT
 
Boiler Operation
Boiler OperationBoiler Operation
Boiler Operation
 
Handling of turbine during emergencies
Handling of turbine during emergenciesHandling of turbine during emergencies
Handling of turbine during emergencies
 
TPS Coal Mills and Fan Performance
TPS Coal Mills and Fan PerformanceTPS Coal Mills and Fan Performance
TPS Coal Mills and Fan Performance
 
Hp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbinesHp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbines
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plant
 
Energy adudit methodology for boiler
Energy adudit methodology for boilerEnergy adudit methodology for boiler
Energy adudit methodology for boiler
 
Turbine Stress Control Logic, Calculation & Working
Turbine Stress Control Logic, Calculation & WorkingTurbine Stress Control Logic, Calculation & Working
Turbine Stress Control Logic, Calculation & Working
 
POWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINEPOWER PLANT SIMULATOR 210 MW LMW TURBINE
POWER PLANT SIMULATOR 210 MW LMW TURBINE
 
Gas turbine
Gas turbine Gas turbine
Gas turbine
 
Pulverized coal fired boiler startup procedure
Pulverized coal fired boiler startup procedurePulverized coal fired boiler startup procedure
Pulverized coal fired boiler startup procedure
 
Coal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plantsCoal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plants
 
The Coal mill performance monitoring
The Coal mill performance monitoringThe Coal mill performance monitoring
The Coal mill performance monitoring
 
Super critical boiler
Super critical boilerSuper critical boiler
Super critical boiler
 
HP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam TurbineHP LP Bypass system of 110 MW Steam Turbine
HP LP Bypass system of 110 MW Steam Turbine
 

Viewers also liked

DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERGopi Chand
 
STUDY OF CONDENSER AND ITS DIFFERENT TYPES
STUDY OF CONDENSER  AND ITS DIFFERENT TYPESSTUDY OF CONDENSER  AND ITS DIFFERENT TYPES
STUDY OF CONDENSER AND ITS DIFFERENT TYPESAziz Rehman
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plantsSHIVAJI CHOUDHURY
 
Waste to energy afval is energie!
Waste to energy afval is energie!Waste to energy afval is energie!
Waste to energy afval is energie!BRONSWERK
 
S3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) NoteS3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) Noteno suhaila
 
Chiller repair, condenser & refrigerant loop test, pump alignment, videos...
Chiller repair, condenser & refrigerant loop test, pump alignment, videos...Chiller repair, condenser & refrigerant loop test, pump alignment, videos...
Chiller repair, condenser & refrigerant loop test, pump alignment, videos...pkpravin89
 
Refining summit 2015
Refining summit 2015Refining summit 2015
Refining summit 2015BRONSWERK
 
Heat exchangers and types
Heat exchangers and typesHeat exchangers and types
Heat exchangers and typesGopesh Chilveri
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticPichai Chaibamrung
 
Heat Exchangers
Heat ExchangersHeat Exchangers
Heat Exchangersmohkab1
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERGopi Chand
 
Condenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant EngineeringCondenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant EngineeringAjaypalsinh Barad
 

Viewers also liked (20)

DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZER
 
Paper 11 icaer_2013modified
Paper 11 icaer_2013modifiedPaper 11 icaer_2013modified
Paper 11 icaer_2013modified
 
STUDY OF CONDENSER AND ITS DIFFERENT TYPES
STUDY OF CONDENSER  AND ITS DIFFERENT TYPESSTUDY OF CONDENSER  AND ITS DIFFERENT TYPES
STUDY OF CONDENSER AND ITS DIFFERENT TYPES
 
Steam Condensers
Steam CondensersSteam Condensers
Steam Condensers
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plants
 
Waste to energy afval is energie!
Waste to energy afval is energie!Waste to energy afval is energie!
Waste to energy afval is energie!
 
Coal Syngas
Coal Syngas Coal Syngas
Coal Syngas
 
S3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) NoteS3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) Note
 
Chiller repair, condenser & refrigerant loop test, pump alignment, videos...
Chiller repair, condenser & refrigerant loop test, pump alignment, videos...Chiller repair, condenser & refrigerant loop test, pump alignment, videos...
Chiller repair, condenser & refrigerant loop test, pump alignment, videos...
 
Refining summit 2015
Refining summit 2015Refining summit 2015
Refining summit 2015
 
Heat exchangers and types
Heat exchangers and typesHeat exchangers and types
Heat exchangers and types
 
Heat Exchangers by Hanif Dewan
Heat Exchangers by Hanif DewanHeat Exchangers by Hanif Dewan
Heat Exchangers by Hanif Dewan
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnostic
 
SYNGAS production
SYNGAS productionSYNGAS production
SYNGAS production
 
Design of condenser
Design of condenserDesign of condenser
Design of condenser
 
Condenser and its types
Condenser and its types Condenser and its types
Condenser and its types
 
Heat Exchangers
Heat ExchangersHeat Exchangers
Heat Exchangers
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZER
 
Steam Condensers
Steam CondensersSteam Condensers
Steam Condensers
 
Condenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant EngineeringCondenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant Engineering
 

Similar to Air heater

Combustion chambers-and-performance
Combustion chambers-and-performanceCombustion chambers-and-performance
Combustion chambers-and-performancemanojg1990
 
New rich text document
New rich text documentNew rich text document
New rich text documentmanojg1990
 
Module 5 Part 2 ppt.pptx
Module 5 Part 2 ppt.pptxModule 5 Part 2 ppt.pptx
Module 5 Part 2 ppt.pptxSahalSachu
 
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Belilove Company-Engineers
 
Cooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpurCooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpurBhanupratap Niranjan
 
Heat-Exchanger-Classification-and-Selection-II.pdf
Heat-Exchanger-Classification-and-Selection-II.pdfHeat-Exchanger-Classification-and-Selection-II.pdf
Heat-Exchanger-Classification-and-Selection-II.pdfTAMILSELVANNATARAJAN3
 
2015 Commercial Products LENNOX
2015 Commercial Products LENNOX2015 Commercial Products LENNOX
2015 Commercial Products LENNOXVictor Neugebauer
 
Design of fin plate heat exchanger
Design of fin plate heat exchangerDesign of fin plate heat exchanger
Design of fin plate heat exchangerBhavesh Solanki
 
SIP Presentation
SIP PresentationSIP Presentation
SIP PresentationAmay Jain
 
Aph operation and emergency handling
Aph operation and emergency handlingAph operation and emergency handling
Aph operation and emergency handlingParag Agrawal
 
Fired Heater Operation and Trouble Shooting.pdf
Fired Heater  Operation and Trouble Shooting.pdfFired Heater  Operation and Trouble Shooting.pdf
Fired Heater Operation and Trouble Shooting.pdfMuhammadNaeem191352
 
Fox Commercial Services PMA Presentation
Fox Commercial Services PMA PresentationFox Commercial Services PMA Presentation
Fox Commercial Services PMA PresentationFox Commercial Services
 
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGER
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGERDESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGER
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGERhemantnehete
 

Similar to Air heater (20)

propulsion 1
propulsion 1propulsion 1
propulsion 1
 
1.6 Propulsion systems.pptx
1.6 Propulsion systems.pptx1.6 Propulsion systems.pptx
1.6 Propulsion systems.pptx
 
Combustion chambers-and-performance
Combustion chambers-and-performanceCombustion chambers-and-performance
Combustion chambers-and-performance
 
New rich text document
New rich text documentNew rich text document
New rich text document
 
Module 5 Part 2 ppt.pptx
Module 5 Part 2 ppt.pptxModule 5 Part 2 ppt.pptx
Module 5 Part 2 ppt.pptx
 
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
 
Cooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpurCooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpur
 
Heat-Exchanger-Classification-and-Selection-II.pdf
Heat-Exchanger-Classification-and-Selection-II.pdfHeat-Exchanger-Classification-and-Selection-II.pdf
Heat-Exchanger-Classification-and-Selection-II.pdf
 
2015 Commercial Products LENNOX
2015 Commercial Products LENNOX2015 Commercial Products LENNOX
2015 Commercial Products LENNOX
 
Design of fin plate heat exchanger
Design of fin plate heat exchangerDesign of fin plate heat exchanger
Design of fin plate heat exchanger
 
Industrial fan(ID FD Fans)
Industrial fan(ID FD Fans)Industrial fan(ID FD Fans)
Industrial fan(ID FD Fans)
 
SIP Presentation
SIP PresentationSIP Presentation
SIP Presentation
 
mechanical engineering design.ppt
mechanical engineering design.pptmechanical engineering design.ppt
mechanical engineering design.ppt
 
Aph operation and emergency handling
Aph operation and emergency handlingAph operation and emergency handling
Aph operation and emergency handling
 
Fired Heater Operation and Trouble Shooting.pdf
Fired Heater  Operation and Trouble Shooting.pdfFired Heater  Operation and Trouble Shooting.pdf
Fired Heater Operation and Trouble Shooting.pdf
 
Industrial compressor
Industrial compressorIndustrial compressor
Industrial compressor
 
Evaporators
EvaporatorsEvaporators
Evaporators
 
Fans and blower
Fans and blowerFans and blower
Fans and blower
 
Fox Commercial Services PMA Presentation
Fox Commercial Services PMA PresentationFox Commercial Services PMA Presentation
Fox Commercial Services PMA Presentation
 
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGER
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGERDESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGER
DESIGN AND FABRICATION OF HELICAL TUBE IN COIL TYPE HEAT EXCHANGER
 

Recently uploaded

(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxbritheesh05
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and usesDevarapalliHaritha
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...srsj9000
 
Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLDeelipZope
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidNikhilNagaraju
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 

Recently uploaded (20)

(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptx
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and uses
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCL
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfidmain PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 

Air heater

  • 2. INTRODUCTION: HEAT EXCHANGER HEAT TRANSFER FROM FLUE GAS TO AIR HEAT REJECTED TO ATMOSPHERE REDUCED INCREASE BOILER EFFICIENCY BY STABILITY OF COMBUSTION WITH HELP OF HOT AIR. HOT AIR USED FOR DRYING THE COAL AS WELL AS FOR TRANSPORTING. FOR EVERY 20°C DROP IN FLUE GAS EXIT TEMPERATURE THE BOILER EFFICIENCY INCREASE BY ABOUT 1%. 10% IMPROVEMENT IN BOILER EFFICIENCY WHEN COMPARED TO AN IDENTICAL UNIT WITHOUT AN APH.
  • 3. Why APH in Boiler System • APH - Tail ender • APH & Economizer are heat recovery • surface • Designers always look at this in pair • Economizer - self limiting characteristics • Can steam if not properly sized • Minimum 25 – 30 deg C Eco out F W & saturation temperature • APH can be sized for any requirement • APH has ability to absorb changes
  • 4. TYPES OF AIR PREHEATERS: AIR PREHEATERS CAN BE CLASSIFIED AS RECUPERATIVE AND REGENERATIVE TYPES BASED ON THEIR OPERATING PRINCIPLE. IN RECUPERATIVE TYPE HEATING MEDIUM I.E. FLUE GAS IS ON ONE SIDE AND AIR IS ON THE OTHER SIDE OF TUBE OR PLATE AND THE HEAT TRANSFER IS BY CONDUCTION THROUGH THE MATERIAL WHICH SEPARATES THE MEDIA. THESE ARE OF STATIC CONSTRUCTION AND HENCE THERE IS ONLY NOMINAL LEAKAGE THROUGH EXPANSION. IN REGENERATIVE TYPE THE HEATING MEDIUM FLOWS THROUGH A CLOSELY PACKED MATRIX TO RAISE ITS TEMPERATURE AND THEN AIR IS PASSED THROUGH THE MATRIX TO PICK-UP THE HEAT. EITHER THE MATRIX OR THE HOODS ARE ROTATED TO ACHIEVE THIS AND HENCE THERE IS SLIGHT LEAKAGE THROUGH SEALING ARRANGEMENTS AT THE MOVING SURFACES.
  • 5. TYPES RECUPERATIVE RE-GENERATIVE STATIC CONSTRUCTION ROTARY BY CONSTRUCTION TUBULAR TYPE PLATE TYPE SCAPH TRI-SECTOR BI-SECTOR Quad-Sector ROTHEMUHLE MATRIX ELEMENT STATIONARY LJUNGSTROM TYPE MATRIX ELEMENT ROTATING HEAT PIPE or THERMOSYPHONE
  • 6. TUBULAR AIR PREHEATER (RECUPERATIVE): •LARGE NUMBER OF STEEL TUBES OF 40 TO 65 MM DIA. •EITHER WELDED OR EXPANDED INTO THE TUBE PLATES. •EITHER GAS OR AIR FLOW THROUGH THE TUBE. •GAS THROUGH THE TUBE NORMALLY REQUIRES HIGHER SIZE TUBE AND VERTICAL FLOW TO REDUCE FOULING. •SINGLE OR MORE PASSES ON THE GAS SIDE AND MULTIPASS CROSS FLOW ON THE AIR SIDE USUALLY FITS IN WITH THE OVERALL PLANT DESIGN. •THE PORTION OF AIRHEATER AT LOW TEMPERATURE ZONE IS DESIGNED NORMALLY WITH A SHORTER TUBE LENGTH SO AS TO FACILITATE MAINTENANCE OF SURFACES DUE TO CORROSION AND FOULING. PLATE TYPE AIR PREHEATER (RECUPERATIVE): •THESE COMPRISE OF PARALLEL PLATES. • WHICH PROVIDE ALTERNATE PASSAGE FOR GAS AND AIR. •THIS TYPE IS SIMPLE AND COMPACT COMPARED TO THAT OF TUBULAR TYPE. •THE NARROW PASSES BETWEEN PLATES MAKE THE CLEANING TEDIOUS BUT WITH SHOT CLEANING METHOD IT IS IMPROVED. •REPLACEMENT IS A MAJOR TASK.
  • 7.
  • 8.
  • 9. LJUNGSTROM REGENERATIVE AIR - HEATER •THE HEAT TRANSFER ELEMENTS ARE ROTATED AT A CONSTANT SPEED AND THEY PASS ALTERNATELY THROUGH GAS AND AIR PASSES. •THE AXIS OF ROTATION MAY BE HORIZONTAL OR VERTICAL. •THE DRIVE IS NORMALLY ELECTRICAL OPERATED THROUGH REDUCTION GEAR WITH COMPRESSED AIR MOTOR AS STAND-BY. •THE PLATES FORMING THE ELEMENTS (MATRIX) MAY BE VARIED IN SPACING AND THICKNESS. •COLD ENDS ARE MADE OF SPECIAL CORROSION RESISTANCE ALLOY SUCH AS CORTEN OR ENAMELED TO ACHIEVE CORROSION RESISTANCE. •THIS TYPE IS VERY COMPACT AND LENDS EASILY FOR DUCTING ARRANGEMENT EFFECTIVE CLEANING OF HEAT-TRANSFER SURFACE BY SOOT BLOWING IS POSSIBLE.
  • 10. • THE BASIC COMPONENT OF THE CONTINUOUSLY ROTATING CYLINDER, CALLED THE ROTOR, THAT IS PACKED WITH THOUSANDS OF SQUARE FEET OF SPECIALLY FORMED SHEETS OF HEAT TRANSFER SURFACES. • AS THE ROTOR REVOLVES, WASTE HEAT IS ABSORBED FROM THE HOT EXHAUST GAS PASSING THROUGH ONE HALF OF THE SURFACE. • THIS ACCUMULATED HEAT IS RELEASED TO THE INCOMING AIR AS THE SAME SURFACES PASS THROUGH THE OTHER HALF OF THE STRUCTURE. THE HEAT TRANSFER CYCLE IS CONTINUOUS AS THE SURFACES ARE ALTERNATELY EXPOS ED TO THE OUTGOING GAS AND INCOMING AIR STREAMS. • FUEL SAVINGS WITH THE LJUNGSTRÖM AIR PREHEATER ARE ABOUT 1-1½% FOR EVERY 4.4°C TO 10°C INCREASE IN COMBUSTION AIR TEMPERATURE, DEPENDING ON THE APPLICATION. •THEIR SIMPLIFIED DESIGN AND OPERATING INTEGRITY ASSURE CONTINUOUS RELIABLE SERVICE THROUGHOUT THE LIFE OF THE PLANT.
  • 11. Size Type Rotor Dia (Meters) Heat Duty(M.K.Cals/Hr) 7 - 16.5 K 1.2 - 3.0 2.5 - 60 17 - 18.5 S 3.2 - 3.8 50 - 70 19 - 24 R 4.2 - 6.6 70 - 200 24.5 - 36 LARGE 6.9 - 20.0 > 200 Range of RAPH Designation of RAPH 27 VI M T 2000 Size number Vertical Shaft; Inverted gas Flow Modular Rotor Trisector Element depth in mm
  • 13. BI-SECTOR THE MAJORITY OF LJUNGSTRÖM AIR PREHEATERS SUPPLIED ARE IN THE BI- SECTOR DESIGN. THESE HEATERS HAVE TWO BASIC STREAMS, ONE OF GAS AND ONE OF AIR.
  • 14. TRI-SECTOR TRI-SECTOR AIR PREHEATER PERMITS A SINGLE HEAT EXCHANGER TO PERFORM TWO FUNCTIONS: COAL DRYING AND COMBUSTION AIR HEATING. THE DESIGN HAS THREE SECTORS - ONE FOR THE FLUE GAS, ONE FOR THE PRIMARY AIR THAT DRIES THE COAL IN THE PULVERIZER, AND ONE FOR SECONDARY AIR THAT GOES TO THE BOILER FOR COMBUSTION
  • 15. • QUADSECTOR •THE QUAD-SECTOR IS WITH FOUR FLOW STREAMS THROUGH THE ROTOR. •THE FOUR SECTORS COMPROMISE ONE GAS AND ONE PRIMARY AIR AS IN THE TRI- SECTOR, BUT THERE ARE TWO SEPARATE SECONDARY AIR SECTORS. •THE DESIGN HAS THE PRIMARY AIR SECTOR’ FLANKED' ON EITHER SIDE BY SECONDARY AIR, AND THIS HAS A BENEFIT ON THE TOTAL AIR- TO-GAS LEAKAGE OF THE UNIT.
  • 16. AIR HEATER –(SCHEMATIC) RADIAL SEAL AXIAL SEAL BYPASS SEAL COLD END HOT END HOT INTERMEDIATE GUIDE BEARING SUPPORT BEARING
  • 17.
  • 18. ROTOR: The rotor is the heart of the equipment radially divided open ended cylinder which contains the heating surface elements. The center shaft of the rotor is called the post. Diaphragm plates extend out ward from the post dividing the rotor into 12 or 24 sectors which are further divided to form compartments into which the element baskets are packed-A pin rack is located around the outside of the rotor to allow it to be rotated by the drive mechanism.
  • 19.
  • 20. HEATING ELEMENTS: They are packed in a reversible containers called baskets, are placed in rotor in three tiers: - Hot, Intermediate and Cold. The notches are used for maintaining the spaces between the elements and minimizing the pressure drop across the air preheater.
  • 21. • HOT END BASKETS & HOT INTERMEDIATE : - Hot End is the first layer & Hot Intermediate is second layer of heating element packing from hot end side. The elements are usually made from 24 gauge / 22 gauge(0.5 – 0.8MM) open hearth steel (IS 513 Gr. DD). They are having a profile called “Double Undulation. The notches run parallel with the rotor axis and provide the correct spacing of sheets and the undulations run at 60° to the notches to impart turbulence. Open-channel element, where the notches, which provide the required plate spacing, rest on a series of point contacts on the adjacent sheet. Flow can move across the element pair because there are openings between the two sheets along the flow length between point contacts.
  • 22. COLD END BASKETS The elements are made of 18 gauge / 22 gauge carton steel. Enameled elements are also used in severe corrosive conditions like for more percentage of sulphur in fuel or for low gas duct temperature. All the heating surface elements are packed into reversible containers called baskets to facilitate easy removal and handling. Cold end baskets are arranged for removal through the basket removal door in the housing. A closed element profile is the notched flat 6-mm element (NF6), the element pair is formed by a series of notches that rest on an adjacent flat sheet with contact along the total flow length. They provide the necessary spacing and form discrete individual flow channels of fixed cross-sectional area along the flow length or element depth. There is no flow communication from one channel to the adjacent one.
  • 23. AIR LEAKAGE • Leakage of the higher pressure air to the lower pressure flue gas through the clearances between the rotor seals and the sector plates. • Air to gas leakage can be increase with time, to more than twice the immediate post overhaul level. • Can be increase with increase in differential pressure of two fluids • Leakage paths for a tri-sector APH are more complex, compared to a bi-sector . • In a tri-sector , primary air leaks into the flue gas and secondary air streams, while SA leaks into the flue gas stream. • Leakage occurs both on the cold end (CE) and hot end (HE). • Due to large difference in pressure between the PA and SA streams, as well as the PA and flue gas streams, leakage in a tri-sector APH is higher than in a bi-sector APH. • Air leakage has the largest single effect on APH performance. • Two penalties to boiler performance occur with excessive radial seal leakage. 1.Thermal losses associated with the leakage air cooling the APH. 2. Additional auxiliary horsepower consumed by the fans for pushing more flow.
  • 24. TYPE OF AIR LEAKAGE A. ENTRAINED LEAKAGE : B. DIRECT LEAKAGE : • THIS IS MAINLY ENTRAPED AIR IN BETWEEN THE HEATING ELEMENTS We = γ . v . rpm. 60 γ = Sp. Wt of air in Kg/m3 v = Volume of Rotor air space • THIS IS MAINLY DUE TO DIFFERENTIAL PRESURE OF TWO FLUID • INCREASE OF SEAL CLEARANCE AT HOT CONDITION • EROSION OF SEALS • IMPROPER SEAL SETTING Wd = α ∗ A *√(2g * γ * ∆ P) α= Coeff. Of flow rate (0.6 – 0.7) g= Acceleration due to gravity A= Gap area at hot condition (m2 ) ∆P= Diff. pr. Of two fluids γ = Sp. Wt of air in Kg/m3 Variable factors are Α & ∆P * Hence amount of entrained Leakage is independent of operating and maintenance condition
  • 25. Circumferential bypass seal leakage into the warm airflow Peripheral bypass seal leakage into the gas path Circumferential bypass seal leakage into the cold gas flow. Hot radial seal leakage Cold radial seal leakage VARIOUS LEAKAGE PATHS THROUGH THE APH
  • 26. It is noted that nearly 80-85% leakage is from Radial Seal 10-15% through By- Pass Seal 5-10% through Axial LEAKAGE PATH
  • 27. THERMAL TURNDOWN When the APH rotor is heated from a cold condition (blue), thermal expansion (yellow) can cause the rotor to droop or “turn down” up to 3 inches on the periphery. Knowing the amount of turndown is important when presetting the seal position before operation, because seal positions will change as the rotor warms to its operating temperature.
  • 28. • SEALING SYSTEM COMPRISES THE FOLLOWING: – RADIAL SECTOR & AXIAL SEALING PLATE – RADIAL, CIRCUMFRENCIAL & AXIAL SEALS – ROTOR POST SEALS – INBOARD & OUTBOARD STATIC SEALS SEALING SYSTEM
  • 29. SEALING SYSTEM: - Usually air leaks into the gas stream due to static pressure differential. This leakage air decrease the air leaving temperature. Various arrangements to reduce the leakage are as follows. The sealing arrangement consists of Radial, Axial, Bypass, Axial Seal Plate to Sector Plate, Static, Rotor Post Seals and Mechanical Sealing Plates designed to minimize leakage between the gas and air streams of the pre-heater. THE RADIAL SEALS are located along the edges of the diaphragm plates and bear against the sector plates, housed under centre sections. THE AXIAL SEALS are located axially in line with the outer edge of diaphragm plates and bear against the axial seal plates, mounted in the housing pedestals. THE BYPASS SEALS are located on the housing around the periphery of the rotor and bear against the T-bar attached to the periphery of the rotor. THE AXIAL PLATE TO SECTOR PLATE SEALS are attached to the axial seal plats and bear against the sector plates. THE STATIC SEALS are fixed under the centre sections and housing pedestals and bear against sector plates and axial seal plates respectively. THE ROTOR POST SEALS are attached to the ends of the rotor posts and bears against the sector plates.
  • 30. SEALING SYSTEM: - – SINGLE LEAF TYPE • Only one sealing strip passing under sector plate & axial seal plate any one time. • Adjusted with no gap due to sharp edge & bend. • 6% reduction in radial seal leakage than channel type.
  • 33. Gaps are observed around the Baskets and with Diaphragm/Stay plates. This will by-pass the flue gas: thereby loosing the efficiency of the boiler. This is revealed by the high flue gas outlet temperature. The newly developed erosion resistant ‘Basket Bypass Seal’, which will permanently close the gaps till the next replacement of the baskets. This will result in lower flue gas outlet temperature, which will improve the efficiency of the Boiler. BASKET BYPASS SEAL
  • 34. CIRCUMFERENTIAL SEALS DEFLECTORS Ideas for deflector Plates and Clay Cloth seals which cater for thermal load dependant rotor position fluctuations have been devised previously.
  • 35. EROSION Erosion caused by fly ash has resulted in the rapid loss of a heat exchange element as well as damage to perimeter seals, radial seals, and rotor diaphragms. Two other factors with regard to erosion are actually more important than ash content: abrasiveness and ash velocity. The abrasiveness of fly ash increases as the amount of silica and alumina increases. Ash velocity is as much as three times more important than ash content or abrasiveness when it comes to determining the rate of erosion. One way to defeat high ash velocity is to increase the fineness of the coal particles leaving the pulverizers and balancing the coal and air flows to each of the burners.
  • 36. CORROSION, PLUGGING AND FOULING A lower flow rate of combustion air results in a lower furnace excess air (excess O2) level, increased CO emissions, increased levels of unburned fuel in fly ash, higher furnace exit gas temperature, increased slagging and fouling rates, and higher net unit heat rate. Cold End Heating elements were seriously affected by corrosion mainly in oil fired boilers. Corrosion causes due to formation of sulphuric acid. To avoid corrosion: a. Complete combustion of fuel oil to be ensured. b. Soot blowing at regular intervals to be done. c. Maintaining minimum cold end average temperature. d. Heating elements to be dried properly after water washing. e. Oil quality to be ensured.
  • 37. FOULING, PLUGGING AND CORROSION: ? Deposits are initiated by condensation of acid or moisture from flue gas on metal surface operating at temperature below dew point i.e. mainly at the cold end, where, as a result, most fouling and corrosion occur. ? Degree of fouling depends on heating element metal surface. ? As coal contains less sulphur, corrosion is not normally as much a problem as fouling and hence lower exit gas temperature to a level of 120 C is permissible. ? But in the case of oil firing, the corrosion and plugging due to corrosive products of combustion are very common. ? The gas outlet temperature and/or air inlet temperature has to be raised to restrict the corrosion to the permissible level. ? Operating the oil fired boiler at very low excess air reduces the acid formation and hence corrosion. ? During starting and at low loads the flue gas exit temperature falls to a low value that will lead to corrosion.
  • 38. One or some of the following method is used to combat the problem: 1. Use of low sulphur oil during the above condition. 2. Air inlet temperature is increased mostly by steam air heating to maintain the recommended cold end average temperature for the installation. 2. Corrosion resistant alloys like corten steel can be used for cold end. 3. Easily and economically replaceable cold end portion of airheater without much outage period. 4. Effective on-load blowing of airheaters with superheated steam as moisture in steam accelerates fouling and corrosion.
  • 39. APH THERMAL EFFICENCY • Gas side efficiency ‘η’gas. • Air side efficiency ‘η’air. • X-Ratio. IF: - Tgi = APH Gas inlet temperature. Tgo = APH Gas outlet temperature. Tai = APH air inlet temperature. Tao = APH air outlet temperature Tgo (nl) = APH Gas outlet temperature at no seal leakage.
  • 40. APH GAS SIDE EFFICIENCY Flue gas inlet temp. – Flue gas outlet temp. at no seal leakage = Flue gas inlet temp. – Air inlet temp. Tgi – Tgo (nl) = Tgi – Tai TgO (nl) = Corrected gas temp. for no seal leakage Al X Cpa (Tgo – Tai) = + Tgo 100 X Cpg AL = % Seal leakage on wt. O2 out – O2 in = X 100 X (0.9 for coal) 21 – O2 o Cpa = Mean specific Heat between Tgi and Tgo Cpg = Mean specific Heat between Tgo and Tgonl Cpa / Cpg = 0.95 for Coal
  • 41. Tao - Tai ηai = X 100% Tgi - Tai Tgi – Tgo (nl) ηgas X-Ratio = = Tgi – Tai ηair 20°C rise in flue gas exist temperature there is decrease in boiler η 1% i.e. = loss of 26 Kcal approx.
  • 42. DRIVE ARRANGEMENT : - The drive mechanism consists of: • Two electric motor connected to a gear reduction unit through overrunning clutch and fluid coupling driving a pinion gear. • The pinion gear meshes with a pin rack on the rotor which allows the rotor to rotate at a low speed. • Provision of Air Motor is also given for any failure of electric drive units. Rotor Drive Assembly (Down Shaft Design) 1. High Speed Coupling 2. Drive Motor (Main) 3. Pin Rack 4. Rotor Housing. 5. Support Bracket 6. Pinion 7. Pinion Cover 8. Speed Reducer 9. Air Motor (Auxiliary)
  • 43. 07. Motor – TEFC: 11 KW, 3 Phase, 50 Hz, 415 V, 1450 RPM, 05-06 Speed Reducer : Type – I Japan, Rissowai 09. Coupling : 11.50 FCU (Pembril) 08. Air Motor = Chiago Pneumatic Air Motor RSM 400 10. Coupling = Bibby 124 A