This document describes the thermal power cycle of a steam turbine power plant. It includes diagrams of the boiler, turbines, condenser and other components. It discusses the efficiencies of the boiler (86.5%), high pressure turbine (81.11%), intermediate pressure turbine (89.83%) and low pressure turbine (85%). It states that the overall steam cycle efficiency is 40%, with 60% of heat being removed by the condenser. Losses at each stage are also outlined.