The document discusses the fabrication and characterization of CuFe2O4 thick film ceramics for use as gamma radiation sensors. It details the fabrication process of screen printing and firing CuFe2O4 paste on alumina substrates. XRD and SEM analysis showed the crystal structure and microstructure of the films. Testing under gamma irradiation from 5-18 mGy demonstrated that films fired under nitrogen gas were more sensitive detectors of radiation than those fired in air. Therefore, both types of CuFe2O4 thick films show potential for use as gamma radiation sensors for low doses below 18 mGy.