This document provides guidance on examining stained sputum smears under a microscope to detect acid-fast bacilli (AFB) and report tuberculosis (TB) infection status. It describes the proper technique for examining smears at 100x magnification by observing at least 300 fields. Smears should be graded based on the number of AFB observed per field as no AFB, scanty (1-9 AFB/100 fields), 1+ (10-99 AFB/100 fields), 2+ (1-10 AFB/50 fields), or 3+ (more than 10 AFB/20 fields). Inaccurate grading can lead to false negatives or false positives, impacting patient treatment and epidemiological analysis
5. OOvveerrvviieeww ooff MMiiccrroossccooppyy
• Place smear facing upwards onto stage
• Focus using 10x objective
• Apply immersion oil and focus 100x
objective
• Examine at least 300 fields
• Quantitate AFB
• Record and report results
• Store all smears
14. OBSERVATION OOFF SSTTAAIINNEEDD SSMMEEAARR
(oolldd MMaallaayyssiiaann ssttaannddaarrdd))
3 cm = 100 visual field
•Examine the smear
under x100 objective
with the 10 eye piece
lens
•Read at least 300 visual
fields to give a report a
negative
15. RReeccoorrddiinngg aanndd rreeppoorrttiinngg
-- mmaaxxiimmuumm 5500 bbaacciillllii iiss ccoouunntteedd
Old Malaysian Standard
If 50 or more bacilli found in the first line > 50 /L
11 to 49 bacilli seen at the end of first line
Write the actual no. of AFB seen
35/L, or
11/L
If 50 bacilli seen in any part of the slides 50/ >L
Number of bacilli seen after 3 lines
examined
Write the actual no. of AFB seen
3/3L or
49 /3L
No AFB seen 0/3L
16. OOBBSSEERRVVAATTIIOONN OOFF SSTTAAIINNEEDD SSMMEEAARR
--IInntteerrnnaattiioonnaall SSttaannddaarrdd--
3 cm = 150 visual field
•Examine the smear
under x100 objective
with the 10 eye piece
lens
•Read at least 300 visual
fields to give a report a
negative
17. Number of AFB Number of fields*
examined
What to report
No AFB in 300
fields 300 fields No Acid Fast Bacilli seen
1–9 AFB in 100
fields 100 fields
Record exact figure
(1 to 9 AFB per 100 fields)
10– 99 AFB in
100 fields 100 fields
1 +
1– 10 AFB in
each field 50 fields
2 +
More than 10
AFB in each
field
20 fields
3 +
* Oil immersion fields
An acceptable size of a smear should be approximately 1-2 cm×2-3 cm. One (1) horizontal line in a 1 x 2 cm smear or in a 2 x 3 cm smear would cover about 100 to 150 visual fields.