ENVIRONMENTAL CONTROL
Air Handling, Air Conditioning and
Refrigeration
Compiled & delivered by,
Mr. N. G. Shinde
Assistant Professor,
Department of Pharmaceutics,
Satara College of Pharmacy, Satara.
2015-2016
3. The manufacturing environment is critical for
product quality
1. Light
2. Temperature
3. Humidity
4. Air movement
5. Microbial contamination
6. Particulate contamination
7. Uncontrolled environment can lead to product degradation
product contamination
loss of product and profit
4. What are contaminants ?
Contaminants are
1. Products or substances other than product
manufactured
2. Foreign products
3. Particulate matter
4. Micro-organisms
5. Endotoxins (degraded micro-organisms)
Cross-contamination is a particular case of contamination
5. Cross-Contamination
What is Cross-Contamination ?
Contamination of a starting material, intermediate
product, or finished product with another starting
material or product during production.
6. Cross-Contamination
From where does Cross-Contamination originate?
1. Poorly designed air handling systems and dust extraction
systems
2. Poorly operated and maintained air handling systems and
dust extraction systems
3. Inadequate procedures for personnel and equipment
4. Insufficiently cleaned equipment
8. Cross-Contamination
Cross-contamination can be minimized by:
1. Personnel procedures
2. Adequate premises
3. Use of closed production systems
4. Adequate, validated cleaning procedures
5. Appropriate levels of protection of product
6. Correct air pressure cascade
16. HVAC
16
HVAC – Heating, Ventilation, Air-conditioning
Temperature
Humidity
Pressure
Ventilation
68°F (20°C) and 75°F (25°C)
30% relative humidity (RH) and 60% RH
A slightly positive pressure to reduce
outside air infiltration.
Rooms typically have several
complete air changes per hour
17. What can HVAC do?
17
Control airborne particles, dust and micro-
organisms
Maintain room pressure (delta P)
Maintain space moisture (Relative Humidity)
Maintain space temperature
18. What HVAC can’t do?
1. HVAC can not clean up the surfaces of a
contaminated places, room or equipment
2. HVAC can not compensate for workers who do not
follow procedures
18
20. Local heating systems
heat source, distributors, and Portable electric heaters, built-in
electric resistance heaters, infrared heaters and wood stoves
Local cooling systems
Air circulation devices, such as paddle or desk fans
Local ventilating systems
Local air-conditioning systems
20
Components Of HVAC System
21. 21
Clean Room
Class
Class Limits "not to exceed" particles per
cu ft for particle sizes shown
0.1∝m 0.2∝m 0.3∝m 0.5∝m 5 ∝m
1 35.0 7.50 3.0 1.0 --
10 350 75.0 30.0 10.0 --
100 -- 750 300 100 --
1000 -- -- -- 1000 7.0
10000 -- -- -- 10000 70.0
10000 -- -- -- 100000 700
Classification Of Clean Room :
REGULATORY POINT OF VIEW
US Federal Standard 209E
22. HEPA FILTER : At Glance
22
High Efficiency Particulate Air capture a minimum of
99.97% of contaminants at 0.3 microns in size.
23. :
Monitoring and Testing of HVAC Clean
Room
Physical
Air borne particulate matter
HEPA integrity
Air Changes per hour
Flow pattern in room
Pressure Diff across filter
Temperature and Humidity
Microbiological
Settling Plate
Slit Plate
Surface Sampling
24. Parameter Test Frequency
Particulate monitoring in air
HEPA filter integrity testing
(DOP testing
Air change rates
Air pressure differentials
Microbiological monitoring
by settle plates
Temperature and humidity
6 Monthly
Yearly
6 Monthly
Daily
Daily
Daily
24
25. Air flow patterns
Filtered air entering a production room or
covering a process can be
turbulent
uni-directional (laminar)
GMP aspect
economical aspect
New technologies: barrier technology/isolator technology.
37. 37
Air conditioning
It is the process of treating the air so as to control its temp.,
humidity, cleanliness and distribution simultaneously to meet
the requirements of the conditioned space.
Applications:
Promoting the human comfort
Maintenance of proper conditions for manufacture, processing and
preserving of material and equipment.
Environmental test chamber
Maintenance of animal and equipment
38. 38
Types of equipment
1.Self contained air conditioner/ Unitary/ Packaged
2.Central air conditioner/ Field erected
1.Self contained air conditioner/ Unitary/ Packaged
These system include window mounted or wall bracket conditioners.
Most of this units are air cooled through water cooled type.
Room air enters the casing at the front panel. It is mixed with part of
the outdoor air and this mixture is forced over a cooling coils by a
centrifugal fans.
39. 39
Central air conditioning system
In this system one or several areas are air conditioned by duct
network.
Air cleaning is done by filters.
Cooling is achieved by using water or by direct expansion in
refrigerated coils or air washers.
Heating is achieved by using steam or hot water coils.
43. 43
Definitions
Humidity:
The amount of water vapour present in moist air per unit mass of the
dry air in given volume.
Dew point:
The temperature at which the liquid droplets just appear when the
moist air is cooled continuously.
Dry bulb temperature:
The actual temperature of gas or mixture of gases indicated by an error
free temperature measuring device.
Wet bulb temperature:
Dynamic equilibrium temperature attained by a water surface when
exposed to air under adiabatic conditions.
44. 44
Measurement of humidity
Direct method
A known volume of air is drawn through phosphorus pentoxide.
The moisture present in the air get absorbed and determined by
chemical or gravimetric method.
From the difference of initial and final masses humidity is
estimated.
46. 46
Dew point method
In this method formation of mist and disappearance of
mist is considered and dew point is calculated.
A cooled and polished disk is placed in vessel
containing the gas whose humidity is to be determined.
The temp. of the disk is gradually lowered using liquid
air or liquid carbon dioxide or ether.
Soon mist condenses on polished surface.
The temperature at which mist just appeared is noted.
The temp. of disk is slowly increased and disappearance
of mist is observed and temp. is noted.
The average of these two temperatures represent
accurate dew point.
47. 47
Humidification
The process of increasing the moisture in the air.
Approaches:
The air may be brought in contact with water in
such a way that only a part of the water is
evaporated.
Cooling towers are utilized.
The incoming air is heated to higher temp. then
cooled adiabatically with water to achieve desired
humidity.
The air may be mixed with stream of air of higher
humidity.
49. 49
Dehumidification
Removal of moisture from the air.
Dehumidification is achieved by bringing the moist air in
contact with cold surface (solid/liquid).
In pharmaceutical industry many operations are carried out at
stated temperature and humidity to get optimum results.
In many parts of India (Bengal, Kerala) air is very humid so it
becomes very difficult to carryon operations with hygroscopic
substances even in AC room. Hence, dehumidifiers are installed
for such operations.
51. Air handling systems:
Play a major role in the quality of pharmaceuticals
Must be designed properly, by professionals
Must be treated as a critical system
Conclusion