SGT-300 Industrial Gas Turbine
Power Generation: (ISO) 7.90MW(e)
Answers for energy.
Industrial Gas Turbines
The Siemens SGT-300 single-shaft
industrial gas turbine is a proven unit
for all electrical power generation and
cogeneration applications. It offers
high efficiency and reliability on a wide
range of gaseous and liquid fuels.
For industrial cogeneration, the high
steam-raising capability of more than
18 tonnes per hour contributes towards
achieving overall plant efficiencies of
80 % or higher. In addition, the compact
arrangement, on-site maintainability
and inherent reliability of the SGT-300
have made it an ideal gas turbine for
the demanding oil and gas industry.
Incorporating proven gas turbine
technology, the SGT-300 offers cost-
effective power for a wide range of
duties including:
Industrial Power Generation
	 Simple-cycle and combined-cycle 	
power plants for base load, standby	
power and peak lopping
	 Cogeneration for industrial
plants with high heat load and
district heating schemes
Power Generation in the
Oil and Gas Industry
	 Offshore: on oil platforms and FPSO
(Floating Production, Storage and 	
Offloading) vessels
	 Onshore: for oil field service, refinery
application, emergency and standby
power generation
	 Highly efficient cogeneration solutions
for oil and gas applications
The SGT-300 has a rugged industrial design which enables high efficiency (nominal
31 %) and excellent emissions performance. These characteristics provide the
flexibility to meet the needs of a broad spectrum of power generation applications.
Key features
	 High simple-cycle and cogeneration
efficiencies, cutting fuel costs
	 Dual-fuel Dry Low Emissions (DLE)
combustion system, meeting
stringent legislation
Maintenance
	 Site maintainability or optional rapid
core exchange as required by customer
	 Designed for maintenance:
- Horizontally split compressor casing
- Horizontally and vertically split
	 inlet casing
- Combustion chambers, flame
	 tubes and ignitors easily accessible
	 for inspection
- Large side-doors on enclosure for
	 equipment change-out
- Package designed for gas turbine
	 removal on either side
	 Multiple boroscope-inspection ports
Customer Support
	 Global support network of Authorized
Service Centers
	 Emergency service -
24/7 specialist helpdesk
	 Full field service
	 Full diagnostic support,
remote monitoring
	 OEM modernizations and upgrades
	 In-house or on-site training programs
	 Range of maintenance and service
contracts available
SGT-300 core engine test facility.
SGT-300 Industrial
Gas Turbine
Technical specifications Gas turbine
Overview
•	 Single-shaft, industrial gas turbine
•	 Power generation: 7.90 MW(e)
(ISO zero loss)	
•	 Frequency: 50 or 60 Hz
•	 Electrical efficiency: 31 %
•	 Heat rate: 11,773 kJ/kWh
(11,158 Btu/kWh)
•	 Compressor pressure ratio: 14:1
•	 Exhaust gas flow: 30.2 kg/s (66.6 lb/s)
•	 Exhaust temperature: 542° C (1008° F)
•	 Typical emissions: NOx <15 ppmV
and CO: <10 ppmV (corrected to
15 % O2 dry)
•	 Medium-calorific value fuels capability
(>32 MJ/Nm3 Wobbe index)
Axial compressor
•	 10-stage
•	 Variable inlet guide vanes
•	 Air flow: (ISO) 29.9 kg/s
•	 Nominal speed: 14,010 rpm
Combustion
•	 6 reverse-flow cannular combustion 	
chambers
•	 Lean-burn Dry Low Emissions (DLE) or
conventional diffusion flame system
•	 High-energy ignitor system
Turbine
•	 2-stage overhung turbine
- First stage air-cooled
Bearings
•	 Tilt-pad radial and thrust
•	 Vibration- and temperature-
monitoring as standard
Main reduction gearbox
•	 Speeds of 1500 rpm and 1800 rpm
Generator
•	 Voltages: 6 to 13.8 kV
•	 Frequency: 50 or 60 Hz
Package
•	 Fabricated steel underbase
- Integral oil tank
- Multi-point mounting
- Optional 3-point mounting
•	 Modular fluid systems
•	 Lubricating oil system
- Gearbox-driven main pump
- AC motor-driven auxiliary pump
- DC motor-driven emergency pump
•	 Oil cooler and oil heater
•	 Electrically-driven hydraulic
start system
•	 Hydrocarbon drains tank on package
•	 Control system
- Siemens SIMATIC PLC-based with
	 distributed control and processing
	 capability installed on package	
-	Optional Allen-Bradley system
-	Optional off-package systems
•	 Vibration monitoring system
- BN 1701: Standard
- BN 3500: Optional
•	 Fire and gas detection equipment
•	 Fire suppression equipment	
•	 On- and off-line compressor cleaning
options availble
•	 Combustion-air inlet-filtration options:
- Simple static
- Pulse cleaning
- HEPA
•	 Enclosure
- Painted carbon steel or
	 stainless steel
- Noise level options
	 (85dB(A) standard)
Heighttotopofpackage:10.82m
Width: 2.85m
Gas turbine package length: 11.75m
Height:3.50m
9
8
3
2
4
7
6
5
SGT-300 package. Two SGT-300 gas turbines provide Norbord with electricity and heat at their
board manufacturing plant in Scotland, UK.
SGT-300 standard package
1 Combustion air inlet
2 Enclosure air outlet
3 Lube oil cooler
4 Enclosure air inlet
5 Unit control panel
6 AC generator
7 Core engine
8 Combustion exhaust
9 Fire extinguishant
Key features
	 Short installation time
	 Compact package size, high power-to-weight ratio
	 Factory testing:
- Core engine
- Functional testing of modules as standard
- Pre-commissioning of package
- Optional core customer-witness test
- Optional complete package test
	 Minimized customer interfaces
- On-package drains tank
- On-package unit control panel
- Roof-mounted oil cooler and air ducting
In cogeneration configuration, with its excellent efficiency
and steam-raising capability, the SGT-300 provides the core of a
reliable, efficient and powerful SSC-300 plant. When compared
with conventional energy supplies, an SSC-300 cogeneration
plant will provide electrical power, heating and/or cooling with
benefits of:
	 Significant reductions in energy costs
	 Security of energy supplies
	 Reductions in total emissions of carbon dioxide,
and improved flexibility
Package Cogeneration with the SGT-300
Nominal generator output and heat rate
Conditions/assumptions:
Altitude: 	 Sea level
Ambient pressure:	 101.3 kPa
Inlet ducting loss:	 1.0 kPa*
Exhaust ducting loss (assumes waste-heat recovery):	 2.0 kPa*
Natural gas fuel.
Gearbox efficiency: 	 99.0 %
Generator efficiency:	 97.0 %
Relative humidity: 	 60 %
*	Duct losses are site-specific according to application.
	Please contact your local Siemens representative or our
	Customer Support Center for performance quotations.
Unfired heat-recovery steam generation
Conditions/assumptions:
Exhaust gas mass flow:	 29.8 kg/s
Assumed feed water temperature:	 100 ° C
Exhaust gas temperature:	 542 ° C
SGT-300 Performance
www.siemens.com /energy
Published by and copyright © 2009:
Siemens AG
Energy Sector
Freyeslebenstrasse 1
91058 Erlangen, Germany
Siemens AG
Energy Sector
Oil & Gas Division
Wolfgang-Reuter-Platz
47053 Duisburg, Germany
Siemens Energy, Inc.
10730 Telge Road
Houston, Texas 77095, USA
Siemens Industrial Turbomachinery Ltd
P.O. Box 1, Waterside South
Lincoln LN5 7FD, United Kingdom
For more information, please contact
our Customer Support Center.
Tel: 	+49 180 524 70 00
Fax: 	+49 180 524 24 71
(Charges depending on provider)
E-mail: support.energy@siemens.com
Oil & Gas Division
Order No. E50001-W430-A106-X-4A00
Printed in Germany
Dispo 34806, c4bs 7447, P WS 12092.5
Printed on elementary chlorine-free bleached paper.
All rights reserved. Trademarks mentioned in
this document are the property of Siemens AG,
its affiliates, or their respective owners.
Subject to change without prior notice. The information
in this document contains general descriptions of the
technical options available, which may not apply in all
cases. The required technical options should therefore
be specified in the contract.
-20 -10 0 10 20 30 40 50
9
8
7
6
5
4
3
2
Engine inlet temperature, º C
Generatorterminalpoweroutput,MW
26
24
22
20
18
16
14
Heat input (MW)
28
Exhaust mass flow (kg/s)
Exhaust temperature (º C)
Pressure, bar g
Steamflow,kg/h
19,000
18,000
17,000
16,000
15,000
14,000
13,000
0 10 20 30 40
Exhaust mass flow
Dry
Saturated
250º C
300º C
350º C
400º C
450º C
Steam temperature (º C)
20,000
21,000
550
26
24
22
20
525
500
475450425
28
30
32

More Related Content

What's hot

Steam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer DesignSteam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer DesignGerard B. Hawkins
 
Training_Manual_MS_5002_BURLINGTON.pdf
Training_Manual_MS_5002_BURLINGTON.pdfTraining_Manual_MS_5002_BURLINGTON.pdf
Training_Manual_MS_5002_BURLINGTON.pdfMebarki Hassane
 
Gas turbines working ppt
Gas turbines working pptGas turbines working ppt
Gas turbines working pptluckyvarsha
 
Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Hammad Akber
 
Start Up Procedures for Primary Reforming Catalyst
Start Up Procedures for Primary Reforming CatalystStart Up Procedures for Primary Reforming Catalyst
Start Up Procedures for Primary Reforming CatalystGerard B. Hawkins
 
Steam turbine condition monitoring
Steam turbine condition monitoringSteam turbine condition monitoring
Steam turbine condition monitoringAbdul Abbasi
 
Iso 2553 s
Iso 2553 sIso 2553 s
Iso 2553 smidheta1
 
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...Gerard B. Hawkins
 
Using aspen plus for process simulation.pptx
Using aspen plus for process simulation.pptxUsing aspen plus for process simulation.pptx
Using aspen plus for process simulation.pptxFsehaGebremichaelGeb1
 
210 mw turbine cycle heat rate
210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rateManohar Tatwawadi
 
Practical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & TechniciansPractical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & TechniciansLiving Online
 
Cnc part programming 4 unit
Cnc part programming 4 unitCnc part programming 4 unit
Cnc part programming 4 unitpalanivendhan
 
236407565 gas-turbine-notes
236407565 gas-turbine-notes236407565 gas-turbine-notes
236407565 gas-turbine-notesmanojg1990
 
Feedstock Purfication in Hydrogen Plants
Feedstock Purfication in Hydrogen PlantsFeedstock Purfication in Hydrogen Plants
Feedstock Purfication in Hydrogen PlantsGerard B. Hawkins
 
Steam ejector working principle
Steam ejector working principleSteam ejector working principle
Steam ejector working principleKarnav Rana
 
07.1 lathe numerical
07.1 lathe numerical07.1 lathe numerical
07.1 lathe numericalM Siva Kumar
 

What's hot (20)

Steam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer DesignSteam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer Design
 
Training_Manual_MS_5002_BURLINGTON.pdf
Training_Manual_MS_5002_BURLINGTON.pdfTraining_Manual_MS_5002_BURLINGTON.pdf
Training_Manual_MS_5002_BURLINGTON.pdf
 
Power Plant Operations.pdf
Power Plant Operations.pdfPower Plant Operations.pdf
Power Plant Operations.pdf
 
Gas turbines working ppt
Gas turbines working pptGas turbines working ppt
Gas turbines working ppt
 
Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)Gas Air Heater (Air Pre Heater)
Gas Air Heater (Air Pre Heater)
 
Start Up Procedures for Primary Reforming Catalyst
Start Up Procedures for Primary Reforming CatalystStart Up Procedures for Primary Reforming Catalyst
Start Up Procedures for Primary Reforming Catalyst
 
Lubricants
LubricantsLubricants
Lubricants
 
Steam turbine condition monitoring
Steam turbine condition monitoringSteam turbine condition monitoring
Steam turbine condition monitoring
 
Iso 2553 s
Iso 2553 sIso 2553 s
Iso 2553 s
 
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
 
Assignment 2
Assignment 2 Assignment 2
Assignment 2
 
Using aspen plus for process simulation.pptx
Using aspen plus for process simulation.pptxUsing aspen plus for process simulation.pptx
Using aspen plus for process simulation.pptx
 
210 mw turbine cycle heat rate
210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rate
 
Practical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & TechniciansPractical Boiler Control & Instrumentation for Engineers & Technicians
Practical Boiler Control & Instrumentation for Engineers & Technicians
 
Cnc part programming 4 unit
Cnc part programming 4 unitCnc part programming 4 unit
Cnc part programming 4 unit
 
236407565 gas-turbine-notes
236407565 gas-turbine-notes236407565 gas-turbine-notes
236407565 gas-turbine-notes
 
Feedstock Purfication in Hydrogen Plants
Feedstock Purfication in Hydrogen PlantsFeedstock Purfication in Hydrogen Plants
Feedstock Purfication in Hydrogen Plants
 
Steam ejector working principle
Steam ejector working principleSteam ejector working principle
Steam ejector working principle
 
Gas turbine
Gas turbine Gas turbine
Gas turbine
 
07.1 lathe numerical
07.1 lathe numerical07.1 lathe numerical
07.1 lathe numerical
 

Viewers also liked

Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016
Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016
Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016MariannN1
 
Presentation busy bee class
Presentation busy bee classPresentation busy bee class
Presentation busy bee classVioletaKO
 
Guía de estudio
Guía de estudio Guía de estudio
Guía de estudio MariannN1
 
Sales is not Marketing
Sales is not MarketingSales is not Marketing
Sales is not MarketingKen Merbler
 
Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...
Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...
Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...Robert Pashman
 
Proyecto del diplomado 2
Proyecto del diplomado 2Proyecto del diplomado 2
Proyecto del diplomado 2rosy2411
 
Ból kręgosłupa Fizjoplaner.pl
Ból kręgosłupa Fizjoplaner.plBól kręgosłupa Fizjoplaner.pl
Ból kręgosłupa Fizjoplaner.plFizjoplaner.pl
 
Dr. Laborda: Los jueces deciden según se les informa
Dr. Laborda: Los jueces deciden según se les informaDr. Laborda: Los jueces deciden según se les informa
Dr. Laborda: Los jueces deciden según se les informaSAD Meeting
 
2016 AEC Excellence - Infrastructure Submissions
2016 AEC Excellence - Infrastructure Submissions 2016 AEC Excellence - Infrastructure Submissions
2016 AEC Excellence - Infrastructure Submissions Teresa Elliott
 
Team Selling 2010
Team Selling 2010Team Selling 2010
Team Selling 2010Ken Merbler
 
Sesion n°10
Sesion n°10Sesion n°10
Sesion n°10Gyna96
 
Proyecto planta de tratamiento de residuos solidos 3
Proyecto planta de tratamiento de residuos solidos 3Proyecto planta de tratamiento de residuos solidos 3
Proyecto planta de tratamiento de residuos solidos 3papeleralacandelaria
 

Viewers also liked (16)

IACR 2016 poster
IACR 2016 posterIACR 2016 poster
IACR 2016 poster
 
Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016
Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016
Primer Convivencia de Estudiantes de Ingeniería Biomédica 2016
 
Armstrong Essay
Armstrong EssayArmstrong Essay
Armstrong Essay
 
Presentation busy bee class
Presentation busy bee classPresentation busy bee class
Presentation busy bee class
 
Guía de estudio
Guía de estudio Guía de estudio
Guía de estudio
 
Caso timers
Caso timersCaso timers
Caso timers
 
Sales is not Marketing
Sales is not MarketingSales is not Marketing
Sales is not Marketing
 
Artigas
ArtigasArtigas
Artigas
 
Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...
Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...
Case Review #8: A 29 year old female firefigher presented with Scheurmanns Ky...
 
Proyecto del diplomado 2
Proyecto del diplomado 2Proyecto del diplomado 2
Proyecto del diplomado 2
 
Ból kręgosłupa Fizjoplaner.pl
Ból kręgosłupa Fizjoplaner.plBól kręgosłupa Fizjoplaner.pl
Ból kręgosłupa Fizjoplaner.pl
 
Dr. Laborda: Los jueces deciden según se les informa
Dr. Laborda: Los jueces deciden según se les informaDr. Laborda: Los jueces deciden según se les informa
Dr. Laborda: Los jueces deciden según se les informa
 
2016 AEC Excellence - Infrastructure Submissions
2016 AEC Excellence - Infrastructure Submissions 2016 AEC Excellence - Infrastructure Submissions
2016 AEC Excellence - Infrastructure Submissions
 
Team Selling 2010
Team Selling 2010Team Selling 2010
Team Selling 2010
 
Sesion n°10
Sesion n°10Sesion n°10
Sesion n°10
 
Proyecto planta de tratamiento de residuos solidos 3
Proyecto planta de tratamiento de residuos solidos 3Proyecto planta de tratamiento de residuos solidos 3
Proyecto planta de tratamiento de residuos solidos 3
 

Similar to Brochure gas turbine sgt 300 for power generation

Similar to Brochure gas turbine sgt 300 for power generation (20)

Ingersoll Rand MT250 Microturbine Product Spec 080LTb
Ingersoll Rand MT250 Microturbine Product Spec 080LTbIngersoll Rand MT250 Microturbine Product Spec 080LTb
Ingersoll Rand MT250 Microturbine Product Spec 080LTb
 
Pre-designed Steam Turbines_EN
Pre-designed Steam Turbines_ENPre-designed Steam Turbines_EN
Pre-designed Steam Turbines_EN
 
Siemens Steam Turbines 45kW-12MW
Siemens Steam Turbines 45kW-12MWSiemens Steam Turbines 45kW-12MW
Siemens Steam Turbines 45kW-12MW
 
Lead free reflow oven s-8800
Lead free reflow oven s-8800 Lead free reflow oven s-8800
Lead free reflow oven s-8800
 
Cpg 2010
Cpg 2010Cpg 2010
Cpg 2010
 
2000REOZM_8_12b (1)
2000REOZM_8_12b (1)2000REOZM_8_12b (1)
2000REOZM_8_12b (1)
 
Reflow Oven S-1000
Reflow Oven S-1000 Reflow Oven S-1000
Reflow Oven S-1000
 
Lead free reflow oven s-1000
Lead free reflow oven s-1000Lead free reflow oven s-1000
Lead free reflow oven s-1000
 
T16K.pdf
T16K.pdfT16K.pdf
T16K.pdf
 
1500REOZM_8_12b
1500REOZM_8_12b1500REOZM_8_12b
1500REOZM_8_12b
 
1250REOZM_8_12b
1250REOZM_8_12b1250REOZM_8_12b
1250REOZM_8_12b
 
1600REOZM_8_12b
1600REOZM_8_12b1600REOZM_8_12b
1600REOZM_8_12b
 
D830.pdf
D830.pdfD830.pdf
D830.pdf
 
1800REOZM_8_12b
1800REOZM_8_12b1800REOZM_8_12b
1800REOZM_8_12b
 
Engine Brochure.pdf
Engine Brochure.pdfEngine Brochure.pdf
Engine Brochure.pdf
 
Hydrogen & Bio Gas Engines Generator sets150 kw to 1 mw 1000kw
Hydrogen & Bio Gas Engines Generator sets150 kw to 1 mw 1000kwHydrogen & Bio Gas Engines Generator sets150 kw to 1 mw 1000kw
Hydrogen & Bio Gas Engines Generator sets150 kw to 1 mw 1000kw
 
KD1000-F.pdf
KD1000-F.pdfKD1000-F.pdf
KD1000-F.pdf
 
Virtual pipelines 201: Industrial CNG Applications Beyond the Pipeline
Virtual pipelines 201: Industrial CNG Applications Beyond the PipelineVirtual pipelines 201: Industrial CNG Applications Beyond the Pipeline
Virtual pipelines 201: Industrial CNG Applications Beyond the Pipeline
 
Dc1370 a 294kw_scr
Dc1370 a 294kw_scrDc1370 a 294kw_scr
Dc1370 a 294kw_scr
 
New Star Plasma Brochure
New Star Plasma BrochureNew Star Plasma Brochure
New Star Plasma Brochure
 

Recently uploaded

Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...
High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...
High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...Call girls in Ahmedabad High profile
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)Suman Mia
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxhumanexperienceaaa
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 

Recently uploaded (20)

Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...
High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...
High Profile Call Girls Dahisar Arpita 9907093804 Independent Escort Service ...
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 

Brochure gas turbine sgt 300 for power generation

  • 1. SGT-300 Industrial Gas Turbine Power Generation: (ISO) 7.90MW(e) Answers for energy. Industrial Gas Turbines The Siemens SGT-300 single-shaft industrial gas turbine is a proven unit for all electrical power generation and cogeneration applications. It offers high efficiency and reliability on a wide range of gaseous and liquid fuels. For industrial cogeneration, the high steam-raising capability of more than 18 tonnes per hour contributes towards achieving overall plant efficiencies of 80 % or higher. In addition, the compact arrangement, on-site maintainability and inherent reliability of the SGT-300 have made it an ideal gas turbine for the demanding oil and gas industry. Incorporating proven gas turbine technology, the SGT-300 offers cost- effective power for a wide range of duties including: Industrial Power Generation Simple-cycle and combined-cycle power plants for base load, standby power and peak lopping Cogeneration for industrial plants with high heat load and district heating schemes Power Generation in the Oil and Gas Industry Offshore: on oil platforms and FPSO (Floating Production, Storage and Offloading) vessels Onshore: for oil field service, refinery application, emergency and standby power generation Highly efficient cogeneration solutions for oil and gas applications The SGT-300 has a rugged industrial design which enables high efficiency (nominal 31 %) and excellent emissions performance. These characteristics provide the flexibility to meet the needs of a broad spectrum of power generation applications.
  • 2. Key features High simple-cycle and cogeneration efficiencies, cutting fuel costs Dual-fuel Dry Low Emissions (DLE) combustion system, meeting stringent legislation Maintenance Site maintainability or optional rapid core exchange as required by customer Designed for maintenance: - Horizontally split compressor casing - Horizontally and vertically split inlet casing - Combustion chambers, flame tubes and ignitors easily accessible for inspection - Large side-doors on enclosure for equipment change-out - Package designed for gas turbine removal on either side Multiple boroscope-inspection ports Customer Support Global support network of Authorized Service Centers Emergency service - 24/7 specialist helpdesk Full field service Full diagnostic support, remote monitoring OEM modernizations and upgrades In-house or on-site training programs Range of maintenance and service contracts available SGT-300 core engine test facility. SGT-300 Industrial Gas Turbine Technical specifications Gas turbine Overview • Single-shaft, industrial gas turbine • Power generation: 7.90 MW(e) (ISO zero loss) • Frequency: 50 or 60 Hz • Electrical efficiency: 31 % • Heat rate: 11,773 kJ/kWh (11,158 Btu/kWh) • Compressor pressure ratio: 14:1 • Exhaust gas flow: 30.2 kg/s (66.6 lb/s) • Exhaust temperature: 542° C (1008° F) • Typical emissions: NOx <15 ppmV and CO: <10 ppmV (corrected to 15 % O2 dry) • Medium-calorific value fuels capability (>32 MJ/Nm3 Wobbe index) Axial compressor • 10-stage • Variable inlet guide vanes • Air flow: (ISO) 29.9 kg/s • Nominal speed: 14,010 rpm Combustion • 6 reverse-flow cannular combustion chambers • Lean-burn Dry Low Emissions (DLE) or conventional diffusion flame system • High-energy ignitor system Turbine • 2-stage overhung turbine - First stage air-cooled Bearings • Tilt-pad radial and thrust • Vibration- and temperature- monitoring as standard Main reduction gearbox • Speeds of 1500 rpm and 1800 rpm Generator • Voltages: 6 to 13.8 kV • Frequency: 50 or 60 Hz Package • Fabricated steel underbase - Integral oil tank - Multi-point mounting - Optional 3-point mounting • Modular fluid systems • Lubricating oil system - Gearbox-driven main pump - AC motor-driven auxiliary pump - DC motor-driven emergency pump • Oil cooler and oil heater • Electrically-driven hydraulic start system • Hydrocarbon drains tank on package • Control system - Siemens SIMATIC PLC-based with distributed control and processing capability installed on package - Optional Allen-Bradley system - Optional off-package systems • Vibration monitoring system - BN 1701: Standard - BN 3500: Optional • Fire and gas detection equipment • Fire suppression equipment • On- and off-line compressor cleaning options availble • Combustion-air inlet-filtration options: - Simple static - Pulse cleaning - HEPA • Enclosure - Painted carbon steel or stainless steel - Noise level options (85dB(A) standard)
  • 3. Heighttotopofpackage:10.82m Width: 2.85m Gas turbine package length: 11.75m Height:3.50m 9 8 3 2 4 7 6 5 SGT-300 package. Two SGT-300 gas turbines provide Norbord with electricity and heat at their board manufacturing plant in Scotland, UK. SGT-300 standard package 1 Combustion air inlet 2 Enclosure air outlet 3 Lube oil cooler 4 Enclosure air inlet 5 Unit control panel 6 AC generator 7 Core engine 8 Combustion exhaust 9 Fire extinguishant Key features Short installation time Compact package size, high power-to-weight ratio Factory testing: - Core engine - Functional testing of modules as standard - Pre-commissioning of package - Optional core customer-witness test - Optional complete package test Minimized customer interfaces - On-package drains tank - On-package unit control panel - Roof-mounted oil cooler and air ducting In cogeneration configuration, with its excellent efficiency and steam-raising capability, the SGT-300 provides the core of a reliable, efficient and powerful SSC-300 plant. When compared with conventional energy supplies, an SSC-300 cogeneration plant will provide electrical power, heating and/or cooling with benefits of: Significant reductions in energy costs Security of energy supplies Reductions in total emissions of carbon dioxide, and improved flexibility Package Cogeneration with the SGT-300
  • 4. Nominal generator output and heat rate Conditions/assumptions: Altitude: Sea level Ambient pressure: 101.3 kPa Inlet ducting loss: 1.0 kPa* Exhaust ducting loss (assumes waste-heat recovery): 2.0 kPa* Natural gas fuel. Gearbox efficiency: 99.0 % Generator efficiency: 97.0 % Relative humidity: 60 % * Duct losses are site-specific according to application. Please contact your local Siemens representative or our Customer Support Center for performance quotations. Unfired heat-recovery steam generation Conditions/assumptions: Exhaust gas mass flow: 29.8 kg/s Assumed feed water temperature: 100 ° C Exhaust gas temperature: 542 ° C SGT-300 Performance www.siemens.com /energy Published by and copyright © 2009: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sector Oil & Gas Division Wolfgang-Reuter-Platz 47053 Duisburg, Germany Siemens Energy, Inc. 10730 Telge Road Houston, Texas 77095, USA Siemens Industrial Turbomachinery Ltd P.O. Box 1, Waterside South Lincoln LN5 7FD, United Kingdom For more information, please contact our Customer Support Center. Tel: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.energy@siemens.com Oil & Gas Division Order No. E50001-W430-A106-X-4A00 Printed in Germany Dispo 34806, c4bs 7447, P WS 12092.5 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. -20 -10 0 10 20 30 40 50 9 8 7 6 5 4 3 2 Engine inlet temperature, º C Generatorterminalpoweroutput,MW 26 24 22 20 18 16 14 Heat input (MW) 28 Exhaust mass flow (kg/s) Exhaust temperature (º C) Pressure, bar g Steamflow,kg/h 19,000 18,000 17,000 16,000 15,000 14,000 13,000 0 10 20 30 40 Exhaust mass flow Dry Saturated 250º C 300º C 350º C 400º C 450º C Steam temperature (º C) 20,000 21,000 550 26 24 22 20 525 500 475450425 28 30 32