The geophysical-based integrated electrical
conductivity (IEC) and the groundwater hydraulic confinement–
overlying strata–depth to water table (GOD)
techniques were used to assess vulnerability levels of
aquifers and the extent of aquifer protection in Abi,
Nigeria. The IEC indices was generated from
constrained one dimensional (1D) inversion of vertical
electrical sounding (VES) and two dimensional (2D)
electrical resistivity tomography (ERT) data, acquired
randomly in the area. The GOD indices were sourced
from existing geologic data within the area. Results
showed that IEC values vary from <0.1>2.0 S in the strongly protected areas.
The GOD indices vary from <0.3 in the lowly vulnerable
areas to 0.6 in the highly vulnerable areas. Thus, the
groundwater resources in the area need to be properly
managed for sustainability and such management practices
have been suggested.
Keywords Electrical resistivity. Contamination .
Vulnerability. IEC . GOD . Abi, Nigeria
Investigation of Groundwater Potential and Aquifer Protective Capacity of Par...Premier Publishers
The aim of this study was to investigate groundwater potential and aquifer protective capacity of an area behind the College of Science, Federal University of Petroleum Resources, Effurun-Warri area of Delta State, Nigeria. The data was acquired using ABEM SAS 4000 Terrameter and processed using IPI2win and Interpex software. Five Vertical Electrical Soundings were carried out with maximum current electrode separation (AB) of 120 m. The VES curves generated from the data revealed HKH curve type for VES 1 and VES 2, KQH curve for VES 3 and KH curve for VES 4 and 5. Five resistivity layers were identified for VES 1 - 3 while four resistivity layers were identified for VES 4 – 5. Analysis and interpretation of VES data obtained from the study area showed VES 3, VES 4 and VES 5 to be most appropriate locations to be explored for borehole development due to low resistivity of the weathered/fractured aquiferous layers coupled with the relatively high thicknesses of the weathered layers. However, all the aquifers in the VES locations are poorly protected due to the very low aquifer protective capacity parameters in the VES locations.
Impact of Locating Boreholes Near Septic Tanks Pit Latrines on Drinking Water...ijtsrd
Water is one of the most indispensible elements of life. One of the major uses of water by man is for drinking, hence drinking water quality has become a major concern in this regard because poor quality water can cause outbreak of major epidemics and death. In this study, impact of locating boreholes near septic tanks pit latrines on drinking water quality in Uyo metropolis, Akwa Ibom State was investigated. The water samples were collected from thirty 30 locations and categorized into i water from boreholes near W near and ii far from septic tanks pit latrines W far . Some physicochemical parameters analyzed were temperature, pH, electrical conductivity, turbidity, dissolved oxygen DO , biochemical oxygen demand BOD5 , salinity i.e. sulphate, carbonate, nitrate, phosphate and chloride ions , total hardness TH , total dissolved solids TDS , total suspended solids TSS and total alkalinity. Pairwise comparison between quality of W near and W far revealed that only BOD 5, TH and TDS had significant mean difference MD at 5 level of probability while their comparison with World Health Organization permissible limit P WHO showed higher significant MD. All the values of parameters were within P WHO, except that of temperature and pH. Based on the results, the water chemistry is tolerable and may not cause any critical damage to the water distribution system as well as utility components. However, treatment is still suggested and boreholes should be drilled some reasonable distances far away from septic tanks pit latrine to guarantee safe drinking water. Akpan, Samuel A | Eze, Bassey E | Assian, Ubong E "Impact of Locating Boreholes Near Septic Tanks/ Pit Latrines on Drinking Water Quality in Uyo Metropolis, Akwa Ibom State" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-6 , October 2020, URL: https://www.ijtsrd.com/papers/ijtsrd33314.pdf Paper Url: https://www.ijtsrd.com/other-scientific-research-area/enviormental-science/33314/impact-of-locating-boreholes-near-septic-tanks-pit-latrines-on-drinking-water-quality-in-uyo-metropolis-akwa-ibom-state/akpan-samuel-a
Geophysical techniques work through applying one of several types of force to the ground, to measure the
resulting energy with use of geophysical equipment and infer the geology from this. Geophysics is generally
much quicker than the aforementioned methods, however, requires more data processing (oìce-based work)
to develop the geological picture. A great advantage of these methods is that certain instruments can be
attached to small aircraft for covering large areas during regional airborne surveys. This provides sparser
geological information, but can highlight potential metal anomalies on a county-country scale, which can be
followed up by more detailed, ground-based geophysical surveys. However, as the material is being tested
indirectly, there is no 100% guarantee of its conclusions; in addition to being susceptible to contamination by
many man-made metallic structures e.g. power-lines. Therefore, should geophysical surveys prove suìciently
interesting, drilling will be required afterwards to conêrm the accuracy of the results.
Investigation of Groundwater Potential and Aquifer Protective Capacity of Par...Premier Publishers
The aim of this study was to investigate groundwater potential and aquifer protective capacity of an area behind the College of Science, Federal University of Petroleum Resources, Effurun-Warri area of Delta State, Nigeria. The data was acquired using ABEM SAS 4000 Terrameter and processed using IPI2win and Interpex software. Five Vertical Electrical Soundings were carried out with maximum current electrode separation (AB) of 120 m. The VES curves generated from the data revealed HKH curve type for VES 1 and VES 2, KQH curve for VES 3 and KH curve for VES 4 and 5. Five resistivity layers were identified for VES 1 - 3 while four resistivity layers were identified for VES 4 – 5. Analysis and interpretation of VES data obtained from the study area showed VES 3, VES 4 and VES 5 to be most appropriate locations to be explored for borehole development due to low resistivity of the weathered/fractured aquiferous layers coupled with the relatively high thicknesses of the weathered layers. However, all the aquifers in the VES locations are poorly protected due to the very low aquifer protective capacity parameters in the VES locations.
Impact of Locating Boreholes Near Septic Tanks Pit Latrines on Drinking Water...ijtsrd
Water is one of the most indispensible elements of life. One of the major uses of water by man is for drinking, hence drinking water quality has become a major concern in this regard because poor quality water can cause outbreak of major epidemics and death. In this study, impact of locating boreholes near septic tanks pit latrines on drinking water quality in Uyo metropolis, Akwa Ibom State was investigated. The water samples were collected from thirty 30 locations and categorized into i water from boreholes near W near and ii far from septic tanks pit latrines W far . Some physicochemical parameters analyzed were temperature, pH, electrical conductivity, turbidity, dissolved oxygen DO , biochemical oxygen demand BOD5 , salinity i.e. sulphate, carbonate, nitrate, phosphate and chloride ions , total hardness TH , total dissolved solids TDS , total suspended solids TSS and total alkalinity. Pairwise comparison between quality of W near and W far revealed that only BOD 5, TH and TDS had significant mean difference MD at 5 level of probability while their comparison with World Health Organization permissible limit P WHO showed higher significant MD. All the values of parameters were within P WHO, except that of temperature and pH. Based on the results, the water chemistry is tolerable and may not cause any critical damage to the water distribution system as well as utility components. However, treatment is still suggested and boreholes should be drilled some reasonable distances far away from septic tanks pit latrine to guarantee safe drinking water. Akpan, Samuel A | Eze, Bassey E | Assian, Ubong E "Impact of Locating Boreholes Near Septic Tanks/ Pit Latrines on Drinking Water Quality in Uyo Metropolis, Akwa Ibom State" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-6 , October 2020, URL: https://www.ijtsrd.com/papers/ijtsrd33314.pdf Paper Url: https://www.ijtsrd.com/other-scientific-research-area/enviormental-science/33314/impact-of-locating-boreholes-near-septic-tanks-pit-latrines-on-drinking-water-quality-in-uyo-metropolis-akwa-ibom-state/akpan-samuel-a
Geophysical techniques work through applying one of several types of force to the ground, to measure the
resulting energy with use of geophysical equipment and infer the geology from this. Geophysics is generally
much quicker than the aforementioned methods, however, requires more data processing (oìce-based work)
to develop the geological picture. A great advantage of these methods is that certain instruments can be
attached to small aircraft for covering large areas during regional airborne surveys. This provides sparser
geological information, but can highlight potential metal anomalies on a county-country scale, which can be
followed up by more detailed, ground-based geophysical surveys. However, as the material is being tested
indirectly, there is no 100% guarantee of its conclusions; in addition to being susceptible to contamination by
many man-made metallic structures e.g. power-lines. Therefore, should geophysical surveys prove suìciently
interesting, drilling will be required afterwards to conêrm the accuracy of the results.
The International Journal of Engineering and Science (The IJES)theijes
The International Journal of Engineering & Science is aimed at providing a platform for researchers, engineers, scientists, or educators to publish their original research results, to exchange new ideas, to disseminate information in innovative designs, engineering experiences and technological skills. It is also the Journal's objective to promote engineering and technology education. All papers submitted to the Journal will be blind peer-reviewed. Only original articles will be published.
The papers for publication in The International Journal of Engineering& Science are selected through rigorous peer reviews to ensure originality, timeliness, relevance, and readability.
THE EFFECT OF GEOTECHNICAL PROPERTIES ON THE BEARING CAPACITY OF SELECTED SOI...IAEME Publication
Study of the characteristics of the physical, chemical and engineering of the soil is considered as an important matter in the processes of engineering projects (such as highways, dams, bridges, etc..). Study was done at selected locations in the governorate of Al-Najaf by drilling three boreholes with 10m depth, for disturbed (DS) and undisturbed (US) samples, to determine soil characteristics, and the level of groundwater depth in the study area because of their effect on the design of foundations. The laboratory and field tests showed that the soil is clayey high plasticity (CH) in most of the study area, while the chemical analysis of the water in the boreholes has a high concentration of SO4 (1031-1037) mg/l and PH values range from (7.7-8.0). The number of blows in the standard penetration (SPT) test was between (58-86) blows. The depth of groundwater was (0.5-0.9) m in the boreholes. The bearing capacity using the dynamic method was (21.45–31.35) T /m² for all boreholes, while the bearing capacity using the static method for depths from (1-3) m ranged from (9.82-14.20) T /m². The study concluded that this soil needs some engineering treatments before establishing the engineering structures.
Analysis of Microstructural Properties of Pliocene Aquifer in the Benin Forma...IOSR Journals
Aquifer microstructural properties were determined using grain size distribution data obtained from
core samples collected during a drilled water borehole. The core samples were collected at depths between 50-
152ft (21.5-65.4 m), corresponding to the aquifer repositories. Samples were oven dried at 800 C for 2hrs. Part
of the samples was used to obtain porosity for aquifer material, while the other part was analyzed mechanically
for particulate size distributions. The effective particulate size distributions at d10, d20 and d60 were obtained and
used to compute the aquifer uniformity coefficient (Cu).The effective particulate size distributions complemented
by eight empirical formulae were deployed to determine hydraulic conductivity of the aquifer. The ratio of the
horizontal hydraulic conductivity to vertical hydraulic conductivity yielded anisotropy values for the aquifer.
Results show that fractional porosity values ranged from 0.282 to 0.492; uniformity coefficient was between 2.5
and 12; horizontal hydraulic conductivity ranged between 0.343 and 2.511 m/day while the vertical hydraulic
conductivity values obtained ranged from 1.320 to 2.907 day/m. Anisotropy values (Av) determined for the
aquifer ranged between 0.118 and 1.005. These results suggest that the aquifer is of gravelly sand within the
deltaic deposit with no clay intercalation and has good potential for groundwater resources.
In order to solve the water scarcity problem in South Malang, East Java,
Indonesia, we have attempted to investigate groundwater by assessing the subsurface
geology and groundwater potential zones. An attempt had been made to identify the
subsurface lithology and aquifer zones by VES (Vertical Electrical Sounding) method
in Pagak, Kepanjen, Kromengan and Gondanglegi district. The study area consists of
major subsurface litho units like sand, silt, clay, tuff, limestone and andesit. In order
to explore the groundwater resources of the study area with an aerial extent of 100
km2, electrical soundings have been conducted by adopting Schlumberger technique
in 12 locations with AB/2 200 m and 5 resistivity profiles were acquired. The field
data were interpreted and processed qualitatively and quantitatively by using
computer software. Considering the geological, geomorphology and hydrogeological
conditions the VES interpretation was done. The study has shown that the region is
underlain by 5 geoelectric layers within the depth penetrated. The groundwater
potential in South Malang reveals four distinct classes (zones) representing ‘Very
good’, ‘good’, ‘moderate’ and ‘poor’ groundwater potential in the area. From the
interpretation result the VES no. 7 (Pagak), and VES no. 9 (Kepanjen) are found to be
prospective for groundwater. It’s also identified that Groundwater occurs under
water table conditions the depth of water table ranges from 5 to 30 m.
Evaluation of Heterogeneous Aquifers in Crystalline Rocks from Resistivity So...theijes
The International Journal of Engineering & Science is aimed at providing a platform for researchers, engineers, scientists, or educators to publish their original research results, to exchange new ideas, to disseminate information in innovative designs, engineering experiences and technological skills. It is also the Journal's objective to promote engineering and technology education. All papers submitted to the Journal will be blind peer-reviewed. Only original articles will be published.
Geohydraulic parameters are essential elements in groundwater resource management and conservation.
Most of these parameters especially the hydraulic conductivity and transmissivity are usually estimated
from pumping test carried out on drilled boreholes. This paper presents a study conducted in Abi area of
the Ikom-Mamfe Embayment with the objective of estimating aquifer parameters from 30 evenly
distributed vertical electrical soundings using the Schlumberger configuration and hydrogeologic
measurements from 28 boreholes within the area as an alternative way of generating an initial data
for groundwater characterisation and quality assessment in the area. The results showed low resistivity
645 Xm, hydraulic conductivity 62.0 105 m/s (61.7 m/day) and transmissivity 65.2 104 m2/s
(645 m2/day) for the water-bearing aquifer horizons in the northeastern and northwestern parts of
the study area due to the nature of the aquifer system that were predominantly fractured shale. The sand
based aquifers had higher values in the neighbourhood of 100–800 Xm, 4.0 105–1.0 104 m/s
(3.46–9.04 m/day) and 6.94 104–3.81 103 m2/s (60–330 m2/day) for the respective parameters
mentioned above. The potability of the groundwater system as observed from hydrogeologic measurements
of water samples from most boreholes were relatively poor, having electrical conductivity
and total dissolved solids values of 250–931.0 lS/cm and 500–623.77 mg/l respectively due to the
influence of clay minerals within the aquifer horizon. Some of the vertical electrical sounding points were
taken in the vicinity were pumping tests and lithologic data were available for adequate comparison of
the results.Electrical resistivity
Geohydraulic parameters
Groundwater
Hydraulic conductivity
Ikom-Mamfe Embayment
Abi-Nigeria
The International Journal of Engineering and Science (The IJES)theijes
The International Journal of Engineering & Science is aimed at providing a platform for researchers, engineers, scientists, or educators to publish their original research results, to exchange new ideas, to disseminate information in innovative designs, engineering experiences and technological skills. It is also the Journal's objective to promote engineering and technology education. All papers submitted to the Journal will be blind peer-reviewed. Only original articles will be published.
The papers for publication in The International Journal of Engineering& Science are selected through rigorous peer reviews to ensure originality, timeliness, relevance, and readability.
THE EFFECT OF GEOTECHNICAL PROPERTIES ON THE BEARING CAPACITY OF SELECTED SOI...IAEME Publication
Study of the characteristics of the physical, chemical and engineering of the soil is considered as an important matter in the processes of engineering projects (such as highways, dams, bridges, etc..). Study was done at selected locations in the governorate of Al-Najaf by drilling three boreholes with 10m depth, for disturbed (DS) and undisturbed (US) samples, to determine soil characteristics, and the level of groundwater depth in the study area because of their effect on the design of foundations. The laboratory and field tests showed that the soil is clayey high plasticity (CH) in most of the study area, while the chemical analysis of the water in the boreholes has a high concentration of SO4 (1031-1037) mg/l and PH values range from (7.7-8.0). The number of blows in the standard penetration (SPT) test was between (58-86) blows. The depth of groundwater was (0.5-0.9) m in the boreholes. The bearing capacity using the dynamic method was (21.45–31.35) T /m² for all boreholes, while the bearing capacity using the static method for depths from (1-3) m ranged from (9.82-14.20) T /m². The study concluded that this soil needs some engineering treatments before establishing the engineering structures.
Analysis of Microstructural Properties of Pliocene Aquifer in the Benin Forma...IOSR Journals
Aquifer microstructural properties were determined using grain size distribution data obtained from
core samples collected during a drilled water borehole. The core samples were collected at depths between 50-
152ft (21.5-65.4 m), corresponding to the aquifer repositories. Samples were oven dried at 800 C for 2hrs. Part
of the samples was used to obtain porosity for aquifer material, while the other part was analyzed mechanically
for particulate size distributions. The effective particulate size distributions at d10, d20 and d60 were obtained and
used to compute the aquifer uniformity coefficient (Cu).The effective particulate size distributions complemented
by eight empirical formulae were deployed to determine hydraulic conductivity of the aquifer. The ratio of the
horizontal hydraulic conductivity to vertical hydraulic conductivity yielded anisotropy values for the aquifer.
Results show that fractional porosity values ranged from 0.282 to 0.492; uniformity coefficient was between 2.5
and 12; horizontal hydraulic conductivity ranged between 0.343 and 2.511 m/day while the vertical hydraulic
conductivity values obtained ranged from 1.320 to 2.907 day/m. Anisotropy values (Av) determined for the
aquifer ranged between 0.118 and 1.005. These results suggest that the aquifer is of gravelly sand within the
deltaic deposit with no clay intercalation and has good potential for groundwater resources.
In order to solve the water scarcity problem in South Malang, East Java,
Indonesia, we have attempted to investigate groundwater by assessing the subsurface
geology and groundwater potential zones. An attempt had been made to identify the
subsurface lithology and aquifer zones by VES (Vertical Electrical Sounding) method
in Pagak, Kepanjen, Kromengan and Gondanglegi district. The study area consists of
major subsurface litho units like sand, silt, clay, tuff, limestone and andesit. In order
to explore the groundwater resources of the study area with an aerial extent of 100
km2, electrical soundings have been conducted by adopting Schlumberger technique
in 12 locations with AB/2 200 m and 5 resistivity profiles were acquired. The field
data were interpreted and processed qualitatively and quantitatively by using
computer software. Considering the geological, geomorphology and hydrogeological
conditions the VES interpretation was done. The study has shown that the region is
underlain by 5 geoelectric layers within the depth penetrated. The groundwater
potential in South Malang reveals four distinct classes (zones) representing ‘Very
good’, ‘good’, ‘moderate’ and ‘poor’ groundwater potential in the area. From the
interpretation result the VES no. 7 (Pagak), and VES no. 9 (Kepanjen) are found to be
prospective for groundwater. It’s also identified that Groundwater occurs under
water table conditions the depth of water table ranges from 5 to 30 m.
Evaluation of Heterogeneous Aquifers in Crystalline Rocks from Resistivity So...theijes
The International Journal of Engineering & Science is aimed at providing a platform for researchers, engineers, scientists, or educators to publish their original research results, to exchange new ideas, to disseminate information in innovative designs, engineering experiences and technological skills. It is also the Journal's objective to promote engineering and technology education. All papers submitted to the Journal will be blind peer-reviewed. Only original articles will be published.
Geohydraulic parameters are essential elements in groundwater resource management and conservation.
Most of these parameters especially the hydraulic conductivity and transmissivity are usually estimated
from pumping test carried out on drilled boreholes. This paper presents a study conducted in Abi area of
the Ikom-Mamfe Embayment with the objective of estimating aquifer parameters from 30 evenly
distributed vertical electrical soundings using the Schlumberger configuration and hydrogeologic
measurements from 28 boreholes within the area as an alternative way of generating an initial data
for groundwater characterisation and quality assessment in the area. The results showed low resistivity
645 Xm, hydraulic conductivity 62.0 105 m/s (61.7 m/day) and transmissivity 65.2 104 m2/s
(645 m2/day) for the water-bearing aquifer horizons in the northeastern and northwestern parts of
the study area due to the nature of the aquifer system that were predominantly fractured shale. The sand
based aquifers had higher values in the neighbourhood of 100–800 Xm, 4.0 105–1.0 104 m/s
(3.46–9.04 m/day) and 6.94 104–3.81 103 m2/s (60–330 m2/day) for the respective parameters
mentioned above. The potability of the groundwater system as observed from hydrogeologic measurements
of water samples from most boreholes were relatively poor, having electrical conductivity
and total dissolved solids values of 250–931.0 lS/cm and 500–623.77 mg/l respectively due to the
influence of clay minerals within the aquifer horizon. Some of the vertical electrical sounding points were
taken in the vicinity were pumping tests and lithologic data were available for adequate comparison of
the results.Electrical resistivity
Geohydraulic parameters
Groundwater
Hydraulic conductivity
Ikom-Mamfe Embayment
Abi-Nigeria
To prevent losing water resources and wetlands, and conserve existing wetlands
ecosystem for ecosystem and biodiversity services, good, wetlands habitats forstart
any sustainable development programs, it is necessary to detect, monitor and
inventory water resources and their surround uplands. Recently, AL-Razaza Lake
suffer from a critical situation because of the decreasing in the water level and
increase a salinity. We have propose a method to monitor and model the spatial and
multi-temporal changes of AL-Razaza Lake in the period 1992–2018. This study
includes pre-processing, processing and post-processing stages. In Addition, a
supervised classification was used to classify the satellite images. Validation result
reveals that the overall accuracies and kappa coefficients of the supervised
classifications were 88, 90.79, 95.94 and 87.67 respectively, and 82%, 86%, 93% and
79% respectively. The results showed that the percentage change was significant
during this period, such that the decreased surface area was from 1313.87 km2 in
1992 to 224.85 km2 in 201.The noticeable results show the rapidly decreasing in the
Lake area by 82.8% with area about 1089.02 km2 over the last three decades. All the
dehydration extended area of the Lake was replaced by soil.
International Journal of Engineering and Science Invention (IJESI) is an international journal intended for professionals and researchers in all fields of computer science and electronics. IJESI publishes research articles and reviews within the whole field Engineering Science and Technology, new teaching methods, assessment, validation and the impact of new technologies and it will continue to provide information on the latest trends and developments in this ever-expanding subject. The publications of papers are selected through double peer reviewed to ensure originality, relevance, and readability. The articles published in our journal can be accessed online.
Experimental evaluation of two-layer air bubble curtains to prevent seawater ...EhsanKahrizi3
The seawater intrusion (SWI) into rivers can lead to many negative consequences, especially on agricultural activities and live ecosystems in upstream areas of rivers. One solution to prevent SWI is using air bubble curtains (ABCs). The objective of this study is to investigate the optimal location of ABCs and airflows. To this end, several tests with different flow and salinity rates were performed and effect of ABC location on SWI investigated. The results show that, when the ratio of seawater to freshwater densities increased from 1.006 to 1.010, the ratio of saline wedge tip velocity to seawater velocity, airflow to seawater discharge ratio for first and second ABCs are raised 60, 58, and 70%, respectively. Also, when the Froude number (Fr) > 0.031, seawater density changes do not significantly affect the process of SWI. Besides, results of the study show that the closer the ABC is to the river downstream, the higher the airflow rates required. In addition, the optimal value of air bubbles for controlling SWI depends on the density of seawater, where more airflow is required to control denser flows. Finally, the regression equations to predict the SWI parameters based on flow properties were derived.
Geo Environmental Investigation of Abuad Dumpsite, Southwestern NigeriaIJERA Editor
Geoenvironmental study of ABUAD female dumpsite was conducted to investigate the suitability of its location
and potential impact on groundwater in the environment. Profiling and Vertical electrical sounding methods
were employed using Dipole - Dipole and Schlumberger configuration respectively. Five points were sounded
and one profile was occupied. Three heterogeneous subsurface lithologic units were established namely; lateritic
topsoil, clayey-sand, and, fresh basement. The curve types are simple H and HA. The topsoil and clayey-sand
materials are characterized with relatively low resistivity values while the fresh basement materials are
characterized with high resistivity values. The average resistivity and thickness values for the topsoil are
280.0Ωm and.2.3m respectively. Clayey-sand was encountered in all the locations with average resistivity and
thickness values of 32.0Ωm and 7.3m respectively. Basement is relatively shallow in the study area, it was
encountered in all the locations with an average resistivity and depth values to the top of basement of 674Ωm,
and 9.6m respectively. Overburden materials are relatively thin within the area with an average resistivity and
thickness values of 156Ωm, and 9.6m respectively. The overburden materials constituting the aquiferous units
within the study area are porous, vulnerable, and good paths for leachate migration. The relatively low
resistivity values within the clayey-sand layers (14 - 61Ωm) are suggestive of leachate intrusion, while relatively
high resistivity values of the impervious basement are due to their crystalline nature. The proximity of the
dumpsite to both the cafeteria and residential halls is a cause for concern.
Application Of Resistivity For Groundwater, Hydrogeology and Pollution ResearchOmokpariolaElshalom
It was a group seminar geophysics course presentation in my year 3 of which I was asked to represent the group in giving an oral presentation of how we can apply resistivity in the geophysical investigation of groundwater, pollution ansd hydrogeology.
Research Inventy : International Journal of Engineering and Scienceinventy
Research Inventy : International Journal of Engineering and Science is published by the group of young academic and industrial researchers with 12 Issues per year. It is an online as well as print version open access journal that provides rapid publication (monthly) of articles in all areas of the subject such as: civil, mechanical, chemical, electronic and computer engineering as well as production and information technology. The Journal welcomes the submission of manuscripts that meet the general criteria of significance and scientific excellence. Papers will be published by rapid process within 20 days after acceptance and peer review process takes only 7 days. All articles published in Research Inventy will be peer-reviewed.
Inland valleys are being used under the Sawah technology for rice production to reduce rice imports to
Ghana. Sawah technology is assumed to benefit from geological fertilization. However, there is no
quantitative information on runoff and sediment flows in the agricultural watershed of Ghana. This
study was carried out at Biemso in the southern part of the country. The aim was to estimate runoff and
sediment transport using the water erosion prediction project (WEPP) model (version 2006.500), from
hillslope to the valley bottom where rice is cultivated using the Sawah technology. A digital elevation
model (DEM) was created from ground survey and used to select the various plots (hillslopes) and to
select slope input parameters. Four plots (hillslopes) were selected for the model simulation. Data on
local daily values of rainfall and on minimum and maximum temperatures were used to set a CLIGEN
model station file to determine climate input parameters for the model. Rainfall characteristics (erosivity
and distribution) were analysed. Soil erodibility was also determined. Soil and crop management input
parameters required by the model were identified and or estimated from field measurements and
secondary sources. The model was run for two management scenarios: Fallow and continuous maize
systems. The results of the simulation showed that 2.9 to 3.9 and 6.8 to 10.2 t/ha/year of sediments were
eroded from upper catchment to valley bottom under fallow system and maize, respectively. The range
of values for runoff produced under fallow was 17.4 to 40 mm whereas that under maize system is 158.7
to 233.62 mm. The study has shown that land use system in the study area has a great influence on
geological fertilization. In addition, the valley bottom where rice is produced under the Sawah system is
enriched with organic matter from upslope.
IJERA (International journal of Engineering Research and Applications) is International online, ... peer reviewed journal. For more detail or submit your article, please visit www.ijera.com
● Heavy Metal Emission Characteristics of Urban Road Runoff
https://ojs.bilpublishing.com/index.php/jees/article/view/1711
● Investigation of Geology and Hydro-geophysical Features Using Electromagnetic and Vertical Sounding Methods for Abu Zabad Area, Western Kordofan State, Sudan https://ojs.bilpublishing.com/index.php/jees/article/view/1279
● Power Spectrum in the Conductive Terrestrial Ionosphere
https://ojs.bilpublishing.com/index.php/jees/article/view/1763
● Thoughts on the Construction of Beautiful Villages with Poverty Alleviation in the Perspective
https://ojs.bilpublishing.com/index.php/jees/article/view/1615
Combined Geophysical And Geotechnical Techniques For Assessment Of Foundation...IRJESJOURNAL
Abstract: This study was carried out to assess the subsurface conditions around the school of technology complex in Lagos State Polytechnic, Ikorodu, using integrated geophysical and geotechnical techniques. The site lies within the Sedimentary terrain of southwestern Nigeria. Allied Ohmega Resistivity meter was used for data collection of 1-D and 2-D resistivitymeasurement while WinResist software and Dipro software were used for the processing respectively.The results of the vertical electrical sounding indicate that the depth to basement values ranges between 27.6 and 39.5m. The 2D resistivitysurvey has provided valuable information on the lateral and vertical variation of the layer competent for erecting foundation of engineering structures. The CPT probed an average depth of 4.8m and has identified material of very high shear strength associated with dense sand materials. The correlation of the three techniques used revealed similar soil layering consisting of topsoilsandy clay, coarse sand and sand.A mechanically stable coarse sand material was discovered as weathered layer which indicates high load bearing capacity suitable for foundation in the area and can support massive structures.
The International Journal of Engineering & Science is aimed at providing a platform for researchers, engineers, scientists, or educators to publish their original research results, to exchange new ideas, to disseminate information in innovative designs, engineering experiences and technological skills. It is also the Journal's objective to promote engineering and technology education. All papers submitted to the Journal will be blind peer-reviewed. Only original articles will be published.
The papers for publication in The International Journal of Engineering& Science are selected through rigorous peer reviews to ensure originality, timeliness, relevance, and readability.
Similar to Aquifer polution vulnerability assessment for abi paper (20)
Artificial Reefs by Kuddle Life Foundation - May 2024punit537210
Situated in Pondicherry, India, Kuddle Life Foundation is a charitable, non-profit and non-governmental organization (NGO) dedicated to improving the living standards of coastal communities and simultaneously placing a strong emphasis on the protection of marine ecosystems.
One of the key areas we work in is Artificial Reefs. This presentation captures our journey so far and our learnings. We hope you get as excited about marine conservation and artificial reefs as we are.
Please visit our website: https://kuddlelife.org
Our Instagram channel:
@kuddlelifefoundation
Our Linkedin Page:
https://www.linkedin.com/company/kuddlelifefoundation/
and write to us if you have any questions:
info@kuddlelife.org
Characterization and the Kinetics of drying at the drying oven and with micro...Open Access Research Paper
The objective of this work is to contribute to valorization de Nephelium lappaceum by the characterization of kinetics of drying of seeds of Nephelium lappaceum. The seeds were dehydrated until a constant mass respectively in a drying oven and a microwawe oven. The temperatures and the powers of drying are respectively: 50, 60 and 70°C and 140, 280 and 420 W. The results show that the curves of drying of seeds of Nephelium lappaceum do not present a phase of constant kinetics. The coefficients of diffusion vary between 2.09.10-8 to 2.98. 10-8m-2/s in the interval of 50°C at 70°C and between 4.83×10-07 at 9.04×10-07 m-8/s for the powers going of 140 W with 420 W the relation between Arrhenius and a value of energy of activation of 16.49 kJ. mol-1 expressed the effect of the temperature on effective diffusivity.
WRI’s brand new “Food Service Playbook for Promoting Sustainable Food Choices” gives food service operators the very latest strategies for creating dining environments that empower consumers to choose sustainable, plant-rich dishes. This research builds off our first guide for food service, now with industry experience and insights from nearly 350 academic trials.
UNDERSTANDING WHAT GREEN WASHING IS!.pdfJulietMogola
Many companies today use green washing to lure the public into thinking they are conserving the environment but in real sense they are doing more harm. There have been such several cases from very big companies here in Kenya and also globally. This ranges from various sectors from manufacturing and goes to consumer products. Educating people on greenwashing will enable people to make better choices based on their analysis and not on what they see on marketing sites.
"Understanding the Carbon Cycle: Processes, Human Impacts, and Strategies for...MMariSelvam4
The carbon cycle is a critical component of Earth's environmental system, governing the movement and transformation of carbon through various reservoirs, including the atmosphere, oceans, soil, and living organisms. This complex cycle involves several key processes such as photosynthesis, respiration, decomposition, and carbon sequestration, each contributing to the regulation of carbon levels on the planet.
Human activities, particularly fossil fuel combustion and deforestation, have significantly altered the natural carbon cycle, leading to increased atmospheric carbon dioxide concentrations and driving climate change. Understanding the intricacies of the carbon cycle is essential for assessing the impacts of these changes and developing effective mitigation strategies.
By studying the carbon cycle, scientists can identify carbon sources and sinks, measure carbon fluxes, and predict future trends. This knowledge is crucial for crafting policies aimed at reducing carbon emissions, enhancing carbon storage, and promoting sustainable practices. The carbon cycle's interplay with climate systems, ecosystems, and human activities underscores its importance in maintaining a stable and healthy planet.
In-depth exploration of the carbon cycle reveals the delicate balance required to sustain life and the urgent need to address anthropogenic influences. Through research, education, and policy, we can work towards restoring equilibrium in the carbon cycle and ensuring a sustainable future for generations to come.
Aquifer polution vulnerability assessment for abi paper
1. Exploratory assessment of groundwater vulnerability
to pollution in Abi, southeastern Nigeria, using geophysical
and geological techniques
Anthony E. Akpan & Ebong D. Ebong &
Chimezie N. Emeka
Received: 16 March 2014 /Accepted: 17 February 2015 /Published online: 4 March 2015
# Springer International Publishing Switzerland 2015
Abstract The geophysical-based integrated electrical
conductivity (IEC) and the groundwater hydraulic con-
finement–overlying strata–depth to water table (GOD)
techniques were used to assess vulnerability levels of
aquifers and the extent of aquifer protection in Abi,
Nigeria. The IEC indices was generated from
constrained one dimensional (1D) inversion of vertical
electrical sounding (VES) and two dimensional (2D)
electrical resistivity tomography (ERT) data, acquired
randomly in the area. The GOD indices were sourced
from existing geologic data within the area. Results
showed that IEC values vary from <0.1 S in the weakly
protected areas to >2.0 S in the strongly protected areas.
The GOD indices vary from <0.3 in the lowly vulnera-
ble areas to 0.6 in the highly vulnerable areas. Thus, the
groundwater resources in the area need to be properly
managed for sustainability and such management prac-
tices have been suggested.
Keywords Electrical resistivity. Contamination .
Vulnerability. IEC . GOD . Abi, Nigeria
Introduction
The groundwater resource in the central parts of Cross
River State in Nigeria is the only source of potable water
for domestic and other uses especially in the dry season
when majority of the surface water resources usually dry
up. Generalised studies have continued to capture the
groundwater system within the area as being capable of
producing potable water that can satisfy the water needs
of the people (Edet and Okereke 2002; Akpan et al.
2013). Recently, anthropogenic contaminants are chal-
lenging the potable status of the groundwater resource in
many parts of Abi. Most of these contaminants are of
human origin from faeces while others originate from
micro- and macro-industrial waste and modern practices
of soil productivity enhancement by farmers who dom-
inate the entire population of the area (Akpan et al.
2013). Considering the intricate nature of vertical water
flow and contaminant transport, faeces from unsewered
sanitary facilities, find their way as Faecal Coliform in
groundwater. The process through which this occurs,
involves the colloidal suspension of faecal materials
with water driven by gravity through permeable forma-
tions and preferential structures such as pores of the
lenticular porous sandy or silty materials, fractures and
joints which are predominant pathways of groundwater
transport in the area (Akpan et al. 2013; Ebong et al.
2014).Values of Faecal and Total Coliform of the range
9.2–19.0 and 20–45 per 100 ml of water respectively
has been observed in some communities within the
study area (Mhomho Technologies & Environmental
Services Ltd 2013; Ebong 2014). Other media through
Environ Monit Assess (2015) 187: 156
DOI 10.1007/s10661-015-4380-2
A. E. Akpan (*) :E. D. Ebong
Applied Geophysics Programme, University of Calabar, PMB
1115, Calabar, Nigeria
e-mail: anthonyakpan@yahoo.com
A. E. Akpan
e-mail: anthonyakpan@unical.edu.ng
C. N. Emeka
Department of Geology, University of Calabar, PMB 1115,
Calabar, Nigeria
2. which contaminants can be transported to the aquifer
horizons by natural processes includes; advection, dif-
fusion and dispersion (Ezzy et al. 2006). The rate and
quantity of contaminants that can be discharged into the
aquifer horizon depend on the hydraulic conductivity
(or permeability) of the vadose zone materials, depth to
water table, groundwater recharge and groundwater
flow media (Foster et al. 2002) Studies have shown that
aquifer systems overlain by thin and porous materials,
lack adequate protection and are susceptible to contam-
ination (Okiongbo and Akpofure 2012). In such areas,
the pores of the sandy or silty materials may serve as
pathways through which contaminants are transported
to the aquifer, since they are not optimally equipped
with the capacity to resist the continuous downward
movement of the contaminants (Sorensen et al. 2005).
Conversely, thick impermeable clay aquitards have the
capacity to strongly resist such movements and can thus
offer sufficient protection to the aquifer (Braga et al.
2006; Gemail et al. 2011).
In the study area, environmentalists are currently
expressing concerns over remediation cost; the eventual
results in the event of full-blown contamination and the
difficulty of controlling the adverse effects of such con-
tamination since majority of water users are tapping
water from the same source (i.e. aquifer) sometimes at
very shallow depths of ~25 m. These shallow aquifers
are localised and heterogeneous due to the blocking of
groundwater flow paths by sandstone hills (Akpan et al.
2013). In most communities, tectonically induced inter-
connected fractures within shaly materials that lack high
filtering capacity as their sandy counterparts are the only
channels of water circulation (Okereke et al. 1998; Raju
and Reddy 1998; Akpan et al. 2013; Ebong et al. 2014).
The circulations of water within these fractured aquifers
are localised (Akpan et al. 2013) hence, will require site-
specific investigations. Such investigations are neces-
sary in order to, not only gain insight into the level of
aquifer protection but also assess the potability status of
the aquifers. Information generated from such investi-
gations are useful in maintaining the quality status of the
aquifers as well as management of the groundwater
resources (Ezzy et al. 2006).
Good understanding of the spatial distribution of the
lithological properties and thicknesses of the overlying
vadose zone materials can be used in assessing the
vulnerability of aquifers. Since the various overlying
lithological materials have different physical character-
istics, geophysical techniques such as the electrical
resistivity, seismic refraction and ground penetration
radar can be used to map the distribution and spatial
spread of these materials. These methods are known to
be economical and less time-consuming (Ebong et al.
2014). The electrical resistivity technique can be used to
infer the distribution of shallow lithological materials
from the variations in resistivity of such materials, since
impermeable argillite-dominated lithologic unit are
characterised by low resistivity values in contrast to
arenite-dominated lithologic units that will be more
resistive (Gemail et al. 2011). The aquifers in most parts
are very shallow and highly vulnerable to contamination
especially in areas overlain by arenaceous materials.
This study is aimed at using electrical resistivity infor-
mation and geological data to
1. assess the level of protection that the fractured and
sandy aquifers in Abi area are current enjoying
2. assess their levels of vulnerability to contamination
3. generate aquifer vulnerability map for the area
4. suggest measures for efficient management and sus-
tenance of groundwater quality.
Hence, this pilot investigation will provide a frame-
work for planning and controlling of human activities on
the land surface within the area.
Aquifer vulnerability assessment
Aquifer vulnerability assessment seeks to quantify the
sensitivity of an aquifer system to groundwater degra-
dation due to human activities. It is an intrinsic property
of the groundwater system that depends on the sensitiv-
ity of the system to the human influence on the surface
and/or natural events (Vrba and Zaporozec 1994;
Almasri 2008). The vulnerability of groundwater cannot
be measured directly; hence, it is a complex function of
the hydrogeologic parameters prevalent within the area
of interest which can serve as protection to the underly-
ing aquifer system or pathways of contaminant transport
(Gogu and Dassargues 2000). It could also be assessed
from the standpoints of analogue models and parametric
systems (Conrad et al. 2002).
Arising from the increasing trends in groundwater
contamination studies, several techniques have been
developed for quantitative assessment of aquifer vulner-
ability to contamination by surface, or near surface
pollutants (Casas et al. 2008). These techniques use
156 Page 2 of 18 Environ Monit Assess (2015) 187: 156
3. information generated from hydrologic, geophysical
and GIS data either in stand-alone basis or in integrated
form to assess the vulnerability of aquifer to contamina-
tion (Neshat et al. 2013). These techniques include the
DRASTIC and its modified varieties that uses seven
hydrological parameters in assessing aquifer vulnerabil-
ity and environmental deterioration (Aller et al. 1987;
Leone et al. 2009; Javadi et al. 2011), the aquifer vul-
nerability index (AVI) method (Draoui et al. 2007;
Ducci and Sellerino 2012; Fraga et al. 2013; Edet
2014), the IEC (Kirsch et al. 2003; Casas et al. 2008),
the groundwater hydraulic confinement–overlying stra-
ta–depth to water table (GOD) method (Foster 1987;
Foster et al. 2002) and SINTACS (Civita and De Maio
1997; Sinkevich et al. 2005; Yin et al. 2012). The DRAS
TIC method is the most widely used in spite of the large
amount of hydrogeological data involved. The
geophysical-based IEC and the GOD techniques use
less number of data but can generate acceptable results
thus, making both techniques popular choices for pre-
liminary evaluation of aquifer vulnerability (Draoui
et al. 2007; Fraga et al. 2013). The IEC and GOD
techniques were used in this pilot study.
Aquifer vulnerability maps show areas of low and
high aquifer vulnerabilities which are vital tools for the
construction of groundwater contamination risk maps
(Perles Roselló et al. 2009; Kirsch 2006). Generally, the
parameters necessary for assessing aquifer vulnerability
depend on the hydrogeological characteristics of the
vadose zone which may encourage or impede contam-
inant transport and on the theory of stratified conductors
(Henriet 1976). Since hydrogeologic conditions such as
permeability of the vadose zone overlying aquifer sys-
tems differ based on geologic settings, the degree of
protection offered to the aquifers will definitely vary.
Thus, different vulnerability ratings will be assigned to
the various aquifers, based on the characteristics of the
vadose zone materials (Casas et al. 2008).
Many researchers have adopted the AVI technique in
assessing the vulnerability of the aquifers to surface
contaminants. The AVI approach uses hydraulic resis-
tance (HR) to the vertical flow of water through the
vadose zone in quantifying aquifer vulnerability (Van
Stempvoort et al. 1992). HR can be computed from
Eq. (1) as
HR ¼
Xn
i ¼ 1
hi
ki
ð1Þ
where hi and ki are thickness and hydraulic conductivity
of the ith layer above the aquifer respectively. In arena-
ceous materials, k values are usually of the range 10−5
–
10−1
m/s and are higher than their argillaceous counter-
parts by several orders of magnitude (Freeze and Cheery
1976; Kirsch 2006). Eq. (1) is based on the assumption
that each layer is intact and multiple layers are perpen-
dicular to the flow direction. In the field, layers are not
perfectly intact due to geologic complexities; hence,
preferential pathways exist which could alter laboratory
measured HR values of geologic materials. Since HR
observations depend on the thickness and lithologic
composition of the local materials in the vadose zone
(Gemail et al. 2011), geophysical techniques such as
electrical resistivity can be used to map their spatial
distribution (Kirsch 2006).
For unconsolidated detrital materials where the bulk
resistivity of the protective layer depends on effective
porosity and quantity of clay as matrix, effective poros-
ity will thus be a dominant factor that controls the value
of HR. Conversely, values of HR for clay dominated
protective layer will depend on the clay content.
Therefore, the magnitude of HR generated from
Eq. (1) will be proportional to the clay content of the
geologic materials (Kirsch 2006). From Eq. (1), HR has
the dimension of time and can be used to estimate the
vertical travel time of water from the surface to the top
of the aquifer (Van Stempvoort et al. 1992). According
to Kirsch (2006), travel time estimates made from the
HR approach are usually crude estimates since influenc-
ing factors such as hydraulic gradient, diffusion and
sorption capacity are ignored in such computations.
Based on the dependence of HR on the lithological
and physical characteristics of the protective layers, the
k term in Eq. (1) can be replaced by the electrical
resistivity (ρ) or its inverse, conductivity (σ ¼ 1
ρ) of the
layer. By this approach, the observed HR results will be
equivalent to the integrated electrical conductivity (IEC)
or geophysical-based protective index (GPI) parameter.
Thus
IEC ¼
Xn
i¼1
hi
ρi
¼
Xn
i¼1
hi  σi ð2Þ
IEC can also be used to assess the vulnerability of
aquifers to surface contamination (Casas et al. 2008).
Ordinarily, the computation of the IEC values is sup-
posed to be a simple arithmetic operation provided hi
and ρi are available from either quantitative
Environ Monit Assess (2015) 187: 156 Page 3 of 18 156
4. interpretation of resistivity sounding, tomographic data
or other sources such as wireline logs, time domain
electromagnetics and geological data. Since quantitative
interpretation of resistivity sounding or tomographic
data is usually not possible due to constraints imposed
by the problem of equivalence, longitudinal conduc-
tance (S) can be used to suppress the associated inter-
pretational ambiguities (Casas et al. 2008). According to
Maillet (1947) and Niwas and Singhal (1981), the lon-
gitudinal conductance, which is one of the Dar Zarrouk
parameters is defined as
S ¼
Xn
i¼1
hi
ρi
ð3Þ
Thus, groundwater circulating in aquifers overlain by
thick lowly resistive geologic formation will have stron-
ger protection from surface pollutants (Casas et al. 2008;
Gemail et al. 2011) and vice versa. The conventional
unit of the IEC is the mho (Ω−1
) otherwise called the
siemens (S).
The acronym GOD in hydrogeology stands for three
dominant contaminant attenuating parameters. The let-
ter G expresses the level of groundwater hydraulic con-
finement and it measures the extent of hydraulic con-
finement of the water circulating within the aquifers.
Since the aquifer can be either fully or partially con-
fined, the hydraulic confinement parameter apportions
varying vulnerability levels to the aquifer. Thus, numer-
ical values assigned to G are such that for unconfined
and fully confined aquifers, G values lie between 1 and
0. The letter O in the acronym represents the bulk nature
of the overlying strata. The O term describes the char-
acter of the materials overlying the aquifers with respect
to their capacity to impede the flow of contaminants.
Values assigned to the O parameter, usually tend to 0 if
the vadose zone materials are dominated by impervious
argillites such as clays, shales, silty sands and fresh
basement rocks such as granite. For arenaceous and
other permeable materials such as loose sands, gravels
and porous limestone materials, weights assigned to the
letter O usually approaches 1. Finally, the letter D in the
acronym represents the depth to the groundwater table.
This parameter is important in assessing the travel time
of the contaminants from the surface or near surface to
the aquifer. Weights assigned to the D parameter in-
creases as the depth to the groundwater decreases.
Since the GOD technique is the product of composite
parameters, final vulnerability ratings for different geo-
logic materials are as shown in Fig. 1.
Physiography of study area
Abi LGA (Fig. 2a) is located between latitudes 5.76° N
and 6.02° N of the Equator and longitudes 7.93° E and
8.71° E of the Greenwich Meridian in Cross River State,
Nigeria (Figs. 2b). Ikwo and Afikpo Local Government
Areas (LGAs) in Ebonyi State bound Abi in the north
and west respectively. It is bordered in the northeast by
Yakurr and Obubra LGAs and bounded in the south by
Biase LGA. Two dominant climatic conditions, the wet
and dry seasons are common in the area. These condi-
tions depict a humid climatic condition with relative
humidity of ~80 %, annual precipitation of ~2,200 mm
and temperatures dropping to as low as 23 °C in the wet
season and rising to ~35 °C in the dry season. The wet
season starts in March when moisture-enriched tropical
maritime air mass that originates from the Atlantic
Ocean blows northward across the area. The air mass
usually begins the gradual process of temporal cessation
of continuous blowing activity in the area around
October which marks the end of the rainy season.
Water levels in both the groundwater and surface water
resources in the area usually attain maximum elevations
above the datum (i.e. mean sea level) in the rainy season.
Sudden increase in aridity, ambient temperature and heat
usually mark the beginning of the dry season in the
month of November and these harsh conditions will
persist till March. The beginning of the dry season
marks the arrival of the tropical continental air mass that
blow southward from the Sahara Desert across the area.
Most of the surface water resources usually dry up in the
dry season leading to severe water scarcity in the entire
area.
Hydrogeology
The dimension of the southward flowing Cross River
which crosses Abi LGA is ~56 km long and ~0.2 km
wide. The Cross River and its tributaries drain the entire
area (Figs. 2a). Abi is located in the middle course of the
river regime where it exhibits a sluggish and meander-
ing flow pattern with huge sand deposits at the beaches.
Some lakes including the Ijum and Ekpon Azogor
Lakes and a few artificial ponds also contributed to the
156 Page 4 of 18 Environ Monit Assess (2015) 187: 156
5. draining of the area. Rainfall is the primary source of
recharge for the numerous water resources in the area.
The volume of water and the amount of sediments that
the Cross River transports across the area is season
dependent. The volume of water in the rivers, streams
and other surface water resources in the area usually
drop to all-seasons low at the peak of the dry season and
water flow in the Cross River is normally restricted to
narrow channels in the riverbed. During the wet season,
there is usually a rapid rise in water levels in the Cross
River and its tributaries, probably due to bank filtration,
flooding, seepage from ponds and direct infiltration of
rainwater most of which forms the bulk of groundwater
recharges in the entire area during the season.
Evapotranspiration is usually high in most of the elevat-
ed areas, thus leaving the groundwater in a predomi-
nantly slightly acidic state (Egboka and Okpoko 1984).
The slightly acidic groundwater usually seeps out of the
hills in the rainy season thereby causing the acidic water
to mix with the other water resources in the area.
Geology, stratigraphy and tectonics of the study area
Abi area is located in the Ikom Mamfe Embayment
(IME) in central Cross River State. The IME is located
between Latitudes 5°15′ N and 6°30′ N of the Equator
and between Longitudes 7°45′ E and 8°45′ E of the
Greenwich Meridian and is the NW–SE splay segment
of the NE–SW trending Benue Trough. The basin ex-
tends laterally into parts of Western Cameroun where it
covers an estimated area of ~2016 km2
(Eseme et al.
2002). The IME appears to be a contiguous part of the
Lower Benue Trough (LBT) (Ukaegbu and Akpabio
2009) and is bounded in the west by the Abakaliki
Anticlinorium, to the east and northeast by the Obudu
None
Overflowing
Unconfined
(covered)
Unconfined
Confined
0.0 0.2 0.4 0.6
Semi-confined
1.0
Lacustrine/
estuarine
clays
Residual
soils
Alluvial silts,
loess, glacial
till
Aeolian
sands
Alluvial and
fluvio-glacial
sands
Alluvial-fan
gravels
UNCONSOLIDATED
(sediments)
Mudstones Siltstones Sandstones
Chalky
CONSOLIDATED
(porous rocks)Shales Volcanic tuffs
Limestones
Calcarenites
Igneous/metamorphic
formations and older
volcanics
Recent
volcanic
lavas
Calcretes +
karst limestones
CONSOLIDATED
dense rocks
0.4 0.5 0.6 0.7 0.8 0.9 1.0
20-50m
5-20m
<-5m
>-50m
Alldepths
0.6 0.7 0.8 0.19.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
NEGLIGIBLE LOW MODERATE HIGH EXTREME
AQUIFER
POLLUTION
VULNERABILITY
DEPTH TO GROUNDWATER
TABLE (unconfined)
OR STRIKE (confined)
OVERLYING STRATA
(lithological character
and degree of consolidationof
vadose zone or confining beds)
GROUNDWATER
CONFINEMENT
Fig. 1 The GOD vulnerability index for various geologic materials (Adapted from Foster et al. 2002)
Environ Monit Assess (2015) 187: 156 Page 5 of 18 156
6. Plateau and the Cameroun Volcanic Line and in the
southeastern part by the Oban Massif (Fig. 3a). It is
characterised by low relief and gently undulating topog-
raphy (Eseme et al. 2002) and covers some communities
in Abi, Ikom, Obubra, Biase and Yakurr LGA of Cross
River State (Figs 3b). Deposition of the Asu River
Group (ARG) on the crystalline basement that underlies
the IME and parts of the LBT has been reported to have
commenced in the Albian time. This deposition marks
the first marine incursion into the area. Migmatitic and
granitic gneisses and schists with some pegmatitic in-
trusions in some locations dominate the basement ma-
terials. The gneisses are usually foliated with some pink
feldspartic materials and vary from black to white horn-
blende. The dominant strike of regional geologic struc-
tures is NE–SW although some occasional N–S swings
have also been reported (Ekwueme et al. 1995; Eseme
et al. 2002). Impervious shales, limestones, sand lenses,
sandstone intercalations and ammonites dominate the
sediments within the ARG (Odigi and Amajor 2009).
Late Albian–Cenomanian thick flaggy impervious cal-
careous and non-calcareous black shales; siltstone and
sandstones dominated Eze-Aku Group (EAG) overlies
the ARG. According to Murat (1972), the sediments of
EAG were deposited under marine condition in a tecton-
ically controlled basin. The regressive and transgressive
cycles of the marine incursion was marked with the de-
position of sandstone, other detrital sediments and argilla-
ceous materials. Brackish marsh and highly fossiliferous
pro-deltaic facies of Late Campanian-Early Maastrichtian
Nkporo Shales Formation (NSF) overlie the EAG (Reijers
and Nwajide 1998). Deposition of the sediments of the
NSF reflects a funnel-shaped shallow marine setting that
graded into channelled low-energy marsh.
Dense, fine-grained and sometimes dark coloured
Tertiary volcanic rocks (e.g. basalts and dolerites) in-
trude these Cretaceous lithostratigraphic units in some
locations. It has been opined that these post Cretaceous
and other low-grade metamorphic activities originated
from the adjoining Cameroun Volcanic Province (CVP).
Fig. 2 Geological map of Abi LGA (a) showing locations of VES stations and ERT profiles. Insert: Map of Nigeria (b) showing location of
Abi LGA
156 Page 6 of 18 Environ Monit Assess (2015) 187: 156
7. These activities resulted in immense alterations in the
primary lithological and physical properties (e.g. porosity,
resistivity) of the overlying Cretaceous lithostratigraphic
units. Thus, the overlying Cretaceous materials are occa-
sionally highly baked, domed and seriously deformed in
many locations (Benkhelil et al. 1975; Offodile 1975).
Tectonic-induced episodes of compressional/
tensional regimes that occurred in Cenomanian and
Santonian times caused significant alterations in the sed-
imentary rocks such as folding and realigning of the
sediments in a predominantly NE–SW direction. These
deformations produce multiple folds and fractures paral-
lel to the fold axis. These episodic tectonic disturbances
led to the formation of the Abakaliki Anticlinorium and
the Afikpo Syncline (Onwualu et al. 2012). In many
locations, the sandstones in the Eze-Aku Group form
ridges that averagely strike at N40o
E and dip between
20° and 68° (Egboka and Uma 1986).
Materials and methods
VES data acquisition and analysis
Physical properties (e.g. electrical resistivity, dielectric
constant and acoustic impedance) of geologic materials
that over- and underlie aquifers are expected to show
reasonable contrast such that a carefully organised elec-
trical resistivity investigation can be used to map their
spatial distribution. From the analysis and interpretation
of such data constrained with geologic and lithologic
information, the distribution of such materials can be
inferred from the discontinuities in the electrical signa-
tures (Casas et al. 2008; Gemail et al. 2011).
Consequently, an experimental design that centres on
electrical resistivity mapping was planned and executed
in the study area.
Electrical resistivity method is a geophysical explo-
ration tool that can be employed in mapping the spatial
distribution of resistivity of earth materials from ob-
served potential differences induced when electrical
current is passed through them via a pair of pointed
electrodes (the current electrodes). The resistivity
methods adopted in the data acquisition in this study
comprise vertical electrical sounding (VES) that was
randomly performed in 40 well-distributed stations
spread across the entire area and five 2D ERT profiles
(Fig. 2a). The VES field procedure was performed using
the Schlumberger electrode array. The choice of the
Schlumberger array was informed by its suitability for
mapping shallow- and deep-seated structures, since
electrodes are expanded on logarithmic basis. For the
purpose of mapping very shallow resistivity variations,
minimum current electrode spacing (AB) was 2 m while
in some locations, field constraints such as the undulat-
ing topography and settlement pattern restricted maxi-
mum current electrode spacing to vary between 500 and
600 m. The corresponding potential electrode spacing
varied from 0.5 m for the minimum electrode spacing to
40 m for the maximum electrode spacing. As is typical
of the VES procedure performed with the Schlumberger
array, the current electrode spacing were increased after
Fig. 3 Generalised geological map of Nigeria showing location of study area (A) and (B) digital elevation map of Abi LGA
Environ Monit Assess (2015) 187: 156 Page 7 of 18 156
8. each acceptable resistance reading and their correspond-
ing potential electrode spacing were increased only when
necessary. In all cases, the MN spacing was such that AB/
2≥5MN/2, so as to validate the potential gradient assump-
tion (Keller and Frischknecht 1966; Dobrin and Savit
1988). Contact resistance problems were severe in the
dry season in some locations but its effect was minimised
by repeated wetting of the electrode positions. The tech-
nique of re-designing the data sheet such that all cross
over points take on integer multiple of their original values
was adopted. This was necessary to aid visual conversion
and comparison of acquired data. The converted data at
the cross over points were checked to ensure that they
satisfy preset repeatability conditions prior to recording
otherwise, measurements were repeated.
The raw apparent resistance data were transformed to
the apparent resistivity domain and smoothened to re-
move noisy data where necessary. Manual interpretation
procedure that involves the matching of field curves
with theoretically prepared curves was performed
(Orellana and Mooney 1966; Rijkswaterstaat 1969).
Partial curve matching procedure was adopted in gener-
ating preliminary layer parameters from the field curve.
The starting model of the inversion process consists
of the raw VES data and the initial layer parameters
generated from the manual procedure. The RESIST
modelling code (Vender Velpen 1988) was used in the
computer aided inverse modelling phase. In the process
of inverting the raw input data, the RESIST code auto-
matically computed theoretical data from the prelimi-
nary layer parameters generated in the manual interpre-
tation phase. A subroutine program within the RESIST
code compares the theoretical data with the raw field
data, computes and displays the difference between the
two sets of data using the root mean square error
(RMSE) technique. Borehole lithologic data near the
VES points obtained from the Cross River State Rural
Water Supply and Sanitation Agency (CRS-RUWATSS
A) were used to provide constraints during the inversion
process to reduce ambiguities in the interpretation stage.
The initial RMSE values were reduced to acceptable
values that suit the starting models by performing a
couple of iterations. The inverse modelling produced
models that best fit the data in a least squares sense
using ridge regression (Inman 1975). Typical VES
curves obtained after the inverse modelling exercise
are shown in Fig. 4.
IECs were computed from the observed layer param-
eters (thicknesses and resistivities) using Eq. (2) and the
results were contoured (Fig. 5a) using SURFER 11
contouring software from Golden Software Inc., USA.
In addition, the inverted results of the Schlumberger
soundings were combined, gridded using the Kriging
method and contoured to generate the resistivity cross-
sections (Fig. 6a and b) that closely approximate the
shallow lithographic sequence in the area. The choice of
the Kriging method was informed by its ability to min-
imise the variance of the estimation error (Van Beers and
Kleijnen 2003; Jassim and Altaany 2013).
ERT data acquisition and analysis
Multi-electrode data were acquired along the profiles
indicated in Fig. 2a using a SAS 1000 model of ABEM
resistivity metre and the ES 10-64 switching unit. The
choice of the 2-D ERT technique was informed by the
desire to generate a laterally extensive (>100 m) high-
resolution subsurface image of the area (Chambers et al.
2011). Such subsurface images were expected to serve
as a visual aid to the pattern of resistivity changes within
the shallow subsurface. The ERT profiles were posi-
tioned along fairly planar ground surfaces in order to
reduce effects of topography on the data. The ERT
imaging was performed using the Wenner electrode
array that is reputed for its capacity to generate data with
high signal to noise ratio (Loke et al. 2003).
Minimum electrode spacing (a) was 3 m while the
maximum was 11 m. Electrical contacts between the
ground and the electrodes were carefully checked and it
was observed that majority of the electrodes have con-
tact resistances that vary between 200 and 300 Ωm. This
range of contact resistances have been reported by
Wilkinson et al. (2010), to be excellent for proper trans-
mission of electrical current into the ground. Water and
brine were used to improve contact resistances between
the ground and the electrodes where necessary.
The reciprocal error (RPE) technique that involves
interchange of the current and potential electrode cable
was adopted for in situ data quality assessment. The
RPE was computed using Eq. (4) with 5 % set as the
maximum acceptable value
e ¼ 100
ρn−ρrj j
ρn þ ρr
ð4Þ
The RPE was observed to be less than 5 % in many
locations but where occasional swings were observed,
measurements were repeated.
156 Page 8 of 18 Environ Monit Assess (2015) 187: 156
9. The ERT data were further filtered and the
RES2DINV software (Loke and Barker 1996; Loke
et al. 2003) was used to model the data. The
RES2DINV software is equipped with codes that enable
Fig. 4 Model VES curves observed at a Egboronyi, b Adadama 1, c Agbara and d Ilike Communities. Insert: Correlation of borehole
lithologs with inverted VES results
Fig. 5 Observed vulnerability maps generated from a IEC and b GOD techniques
Environ Monit Assess (2015) 187: 156 Page 9 of 18 156
10. the computer to execute finite difference modelling and
non-linear smoothness-constrained least-squares opti-
mization procedures. Thus, the software can calculate
apparent resistivity and the resistivity values of the
model blocks respectively (de Groot-Hedlin and
Constable 1990). In the process of executing the sub-
routine commands, the RES2DINV subdivides the sub-
surface into rectangular grids that are equal in number to
the number of data points and iteratively adjusts the
resistivity model of each block by minimising the dif-
ference between the observed and the calculated resis-
tivity values. It eventually transforms the measured ERT
data into an approximate picture of the true subsurface
resistivity distribution and geometry (Olayinka and
Yaramanci 2000). This procedure is known to produce
smooth variations in subsurface resistivity distribution
with depth (Loke et al. 2003) especially in areas with
geologic constraints. The RMSE technique was also
adopted in quantifying the difference between the theo-
retical and the observed data sets, which was iteratively
minimised until a satisfactory fit was obtained. Samples
of the ERT-derived subsurface images are shown in
Fig. 7.
The GOD data acquisition
Relevant information on the nature and spatial distribution
of the confining materials in the area were sourced from
the geologic map of Abi LGA (Fig. 2a). Results obtained
from the 1D and 2D modelling of resistivity data were
used in assessing the vertical continuity of the various
lithologic units. After ascertaining the confining conditions
of the aquifers in the entire area using geophysical and
geological information, numerical values that vary be-
tween 0.2 and 0.4 were assigned to the G parameter.
Generally, low values were assigned to G because imper-
vious materials that range from consolidated materials such
as shalestones, siltstones sandstones and claystones to
thick argillaceous materials such as clays, shales and silts
overlie over 85 % of the entire area. The lineament map of
the area (Fig. 8) was used to provide constraints on the
Fig. 6 Resistivity cross-sections
generated along profiles a A–A′
and b B–B′
156 Page 10 of 18 Environ Monit Assess (2015) 187: 156
11. numerical values assigned to G. Where lineaments were
observed, a value of 5 was assigned to the G parameter.
Impervious arenaceous sandstones, argillites and their
deformed counterparts dominate the geology. Therefore,
the indices for the O parameter were made to vary be-
tween 0.4 and 0.7. Static water level (SWL) observations
from 40 boreholes in the area were used in selecting
values of the D parameter. The SWL data were observed
to vary between 2 m in Adadama Community and ~17 m
at Igoni-Igoni Community. Locations with SWLs below
5 m were assigned D index value of 0.9 while locations
where SWL variations were observed to vary between 5
and 20 m were assigned D index of 0.8 in accordance
with the classification of Foster et al. (2002) (Fig. 1). The
GOD indices were averaged, gridded and contoured on
Abi map (Fig. 5b) in order to assess its spatial variation.
The two maps (IEC and GOD) are shown in Fig. 5.
Results and discussions
The inferred shallow surface electrostratigraphy and
layer parameters (Table 1) generated from the inversion
process were in good agreement with available borehole
lithologic logs closest to some of the VES stations
(Fig. 4).
Litho- and hydro-resistivity cross-sections
The two VES-derived resistivity cross-sections
(Fig. 6a, b) capture the shallow subsurface of the area
as being dominated by thickly bedded argillaceous and
arenaceous materials that are characterised by low resis-
tivity (ρ<150 Ωm) value. The argillites are usually
capped by some more resistive (ρ>700 Ωm) sandstone
materials with variable thicknesses. The sandstone
Fig. 7 Representative subsurface images generated using the ERT technique
Environ Monit Assess (2015) 187: 156 Page 11 of 18 156
12. materials are exposed extensively in many communities
in the area. In the north–south profile (Fig. 6a), the
sandstone materials are characterised by high resistivi-
ties (ρ>1,000 Ωm) and thicknesses that do reach 5 m in
some locations. These materials are underlain by thickly
bedded argillites whose vertical continuity is occasion-
ally truncated by some more resistive sandy materials
(ρ>100 Ωm). These sandy materials are characterised
by variable thicknesses and are saturated with site-
dependent discharge rate. According to Akpan et al.
(2013) and Petters (1989), this sandy horizon has low–
high groundwater yield and is the dominant source of
potable water in the area. The overlying sandstones and
the adjoining clayey materials form the protective cap
that seals the interbedded sandy materials from surface
contaminants. The overlying sandstones and argilla-
ceous materials and the underlying argillaceous mate-
rials also serve as the confining units for the aquifers.
The level of aquifer confinement is site dependent due to
the abundance of subsurface structural discontinuities
such as fractures (Fig. 6a) appearing to exert significant
influence on them. These structural discontinuities (e.g.
fractures and joints) serve as preferential pathways for
contaminant transport.
The thickness of the interbedded sandy aquifers
varies with spatial location and its resistivity values
seem to depend on the extent of saturation, composition
of the saturating fluid andlithological composition. Near
the surface where the sandy materials are fairly sorted
and the pores are air filled, resistivity values were high
(ρ>700 Ωm) compared to the sandy materials at deeper
depths where the pores are water filled. Underlying the
sandy materials are sets of moderately resistive argilla-
ceous materials with vertical continuity that extends
beyond 70 m. Thus, the sandy aquifers exist in a ful-
ly–partially confined state though at shallow depth.
In the NE–SW oriented AA′ resistivity profile that
runs through the NSF (Fig. 6b), high resistivity (ρ>
1,000 Ωm) arenaceous materials with south-west in-
creasing thickness, cap the entire lithostratigraphic se-
quence. From the beginning of the profile to ~8 km, the
sandstone materials are ~1 m in vertical extent while
their thickness increased to ~15 m in the other part of the
profile. Moderately consolidated argillaceous materials
(ρ<200 Ωm) with variable thicknesses directly underlie
the sandstone materials. From the northeastern section
up to ~5 km along the profile, argillaceous materials
dominate the entire lithostratigraphic sequence.
Fig. 8 Lineament map of Abi,
Nigeria
156 Page 12 of 18 Environ Monit Assess (2015) 187: 156
14. However, from ~5 km to the end of the profile, moderate
resistivity (ρ<600 Ωm) sandstone materials were ob-
served to intercalate with the argillaceous materials.
These intercalating sandy materials are saturated at shal-
low depth range of ~20 to 55 m. Thus, the shallow
aquifers exist under partially to fully confined conditions.
Three representative ERT images of the area are
shown in Fig 7. The shallow subsurface image of ERT
1 located in the NSF shows moderately resistive sandy
materials (ρ>100 Ωm) with nearly uniform thickness
(~3 m) which cap the lithostratigraphic sequence. These
overlying arenaceous materials lie almost horizontal to
the underlying argillaceous materials. Low–moderate
resistivity (ρ<100 Ωm) argillaceous materials that dom-
inate the shallow subsurface image underlie the sand-
stones materials. These shaly materials extend beyond
15 m. The low resistivity (ρ<10 Ωm) associated with
these materials seem to be indicative of an area where
wastewater from cassava processing mills accumulates.
The subsurface image from ERT 2 (Fig. 7) that was
also stationed in the NSF show that, low resistivity (ρ<
50 Ωm) nearly parallel argillaceous materials overlie the
lithostratigraphic sequence. The clayey materials are
~5 m in thickness from the beginning up to ~40 m along
the profile. From ~40 m point, thickness of the argilla-
ceous materials increases to~12 m. Relatively high
resistivity (ρ>75 Ωm) arenaceous materials underlie
the clayey materials and dominate the entire image
beyond 17 m. These results show that the aquifers are
moderately protected since thin impermeable argilla-
ceous and consolidated arenaceous materials overlie
them. ERT 2 correlates strongly with results of VES
17 and the lithologic log of a close borehole (Fig. 7).
ERT 3 (Fig. 7) that was positioned in the EAG shows
that high resistivity (ρ>1,000 Ωm) arenaceous materials
that are in direct contact with some conducting clayey
materials dominate the subsurface from ~27 m to the
end of the profile. These arenaceous materials dip gently
eastward and are over 10 m thick in some locations.
Moderately resistive sandy–clay (ρ<800 Ωm) are dom-
inant from the beginning of the profile up to 27 m. The
high resistivity values suggest that the sandy–clay exist
in a highly deformed state.
Aquifer protection based on IEC and GOD indices
The aquifers in the study area, which are major source of
potable water for the people, are shallow (≤50 m) and
therefore the level of protection offered by the vadose
zone materials need to be established quantitatively. The
spatial distribution of IEC values and GOD indices in the
area are shown in Fig. 5 a, b. Observed values of the IEC
and the GOD indices were compared (Table 2) and the
IEC showed better representation and correlates with
geology. The resistivity cross-sections (Fig. 6) were also
used to assess the thickness of the vadose zone in the area.
IEC values range from <0.1 S for the weakly
protected aquifers to >2.0 S for strongly protected aqui-
fers. The pattern of IEC variation in the area is unsys-
tematic because it appears to be independent of factors
such as properties of the soil, net recharge and charac-
teristics of the unsaturated layer (Casas et al. 2008) that
are known to influence IECs. Rather, IEC values show
strong dependence on depth to the aquifer, which in turn
depends on the paleotectonic disturbances in the area
(Onwualu et al. 2012). These paleotectonic activities
seem to be a dominant factor that dictates the behaviour
of many geological structures in the area including the
dominant course of the Cross River. In some communi-
ties, e.g. Usumutong and Ebom in the southeastern
region, Itigidi at the centre, Ekureku in the northern part,
Adadama and Igbo Imabana in the northeastern part
(Figs. 2a, 3b and 8) where fractured materials overlie
the aquifer horizon (Ebong et al. 2014), the aquifers
were observed to be weakly-fairly protected with IEC
values varying between 0.1 and ~0.4 S.
The GOD indices vary from <0.30 in the lowly
vulnerable areas to 0.65 in the highly vulnerable areas.
The values of the GOD indices show that the aquifers in
Abi have moderate-high vulnerability to contamination.
This observation corroborates with the IEC results
(Table 2). Although laterally extensive impermeable
materials overlie aquifers in Abi, the lack of reasonable
thickness for proper contaminant attenuation by natural
process in many locations and fracturing of the overly-
ing consolidated materials (Fig. 8) can provide prefer-
ential pathways through which contaminants get to the
aquifers. In some isolated areas where the vadose zone
materials are reasonably thick, the vertical flow of
Table 2 General vulnerability and protective capacity classes
IEC (S) Protective capacity GOD Vulnerability rating
>2.0 Strong <0.3 Low
1.1–2.0 Moderate 0.3–0.5 Moderate
0.1–1.0 Fair 0.5–0.7 High
<0.1 Weak >0.7 Extreme
156 Page 14 of 18 Environ Monit Assess (2015) 187: 156
15. contaminants can be impeded by mechanical, physico-
chemical, microbiological and other natural processes.
These areas are located on topographic highs (Fig. 3b)
that incidentally correspond to regions of groundwater
recharge. Here, surficial contaminants and water migrate
into deeper layers through fractures (Akpan et al. 2013).
These fractures are characterised by large pore spaces
that naturally lacks the capacity to attenuate contami-
nants (Ebong et al. 2014). Most of the communities
where these weakly protected aquifers abound are loca-
tions where the farmers also practice yield enhancement
farming methods. Thus, with the high elevations and
steepness of slope, topographically induced flow gradi-
ent will drive surface water that are contaminated with
fertilizer, pesticides or other contaminants downhill into
the low lying areas (Akpan et al. 2013) thereby reducing
the rate at which contaminants infiltrate into the aquifer
horizon. However, during such downhill flows, the ten-
dency of the contaminated water to be driven into the
aquifer horizon via fractures and joints is certain al-
though at low rates and so can be neglected.Aquifer
protection based on the IEC in other communities varies
from 1.1 to ~2.6 S depicting a group of moderate to
strongly protected aquifers. These groups of aquifers are
dominant in the northern, southern, southeastern, south-
western and central parts of the study area (Fig. 5a)
where the EAG and NSF are dominant. Within these
geologic formations, the aquifers consist of sandy/
gravelly materials that are overlain by thick imperme-
able clayey/shaly materials and their metamorphosed
varieties. The impermeable and thick clay overburden
materials which are charaterised by low hydraulic con-
ductances serve as natural filters to any percolating fluid
(Sharma and Baranwal 2005; Yadav and Singh 2007;
Ebong et al. 2014). These materials reduce the rate of
movement of the fluid through them hence, increasing
their residence time and offering better protection to the
underlying aquifers.
Suggested management practices
Potential management practices for sustaining the aqui-
fers are as follows;
1. Faecal and total coliforms are human borne contam-
inant. Their menace can be minimised by the adop-
tion of good sanitary practices. Therefore, massive
education and reorientation on sanitary habits will be
the most powerful tool needed to curb its menace.
2. If inorganic chemical fertilizers especially those
enriched with nitrogenous compounds must be ap-
plied to the soils, the quantity, type and the time of
application must be carefully managed. This ap-
proach is the most practical, most acceptable and
standard practice in minimising groundwater con-
tamination resulting from the application of fertil-
izers, thereby sustaining groundwater quality within
such areas. The number of times that nitrogenous
fertilizers must be applied to the farm per season
must be properly regulated (Yadav and Wall 1998).
3. Other less harmful sources of soil nitrogen includ-
ing the use of organic substances to improve soil
fertility and consequently, crop yield should be con-
sidered (Waskom 1994).
4. The period of application of inorganic fertilizers
must be carefully planned so that it does not coin-
cide with the peak period of leaching, which in the
area will coincide with the peak period of rainfall of
June and July. Thus, fertilizer application must be
done at the period of maximum crop uptake.
5. The current practice of shifting cultivation, which is
the dominant system of farming, should be
sustained in spite of its short coming. This method
has the capacity of restoring lost soil fertility natu-
rally before the next cultivation period.
6. Industrialists should be encouraged to embrace en-
vironmental friendly methods of waste management
such as waste recycling in order to reduce their
impacts on the environment.
Conclusion
This study was embarked upon to quantitatively rate the
level of protection that will be of advantage or otherwise
to the fractured shales/sandy aquifers, which are the
major sources of potable water for the people in Abi-
Nigeria. Abi area was selected because it is an area
where inorganic wastes resulting from soil productivity
enhancement techniques and micro-industrial activities
are prevalent. The geophysical data used were the elec-
trical resistivity data generated from forty VES and five
100 m long 2-D ERT profiles. The geological data used
include the generalised geological, borehole lithologic
and tectonic information of the area. Both manual and
computer modelling techniques were adopted in
converting the measured field data to their geologic
Environ Monit Assess (2015) 187: 156 Page 15 of 18 156
16. equivalents using borehole lithologic data as constraints.
Interpreted layer resistivities and thicknesses were used
in computing the geophysical protective index (or IEC)
for lithologies that overlie the aquifers.
Results show that the composition of the aquifer
horizon varies from fractured shales –fractured sand-
stones to sandy/gravelly materials in the EAG and
NSF dominated areas. The aquifers exist under partially
confined to fully confined conditions. The composition
of the overlying materials varies from argillaceous ma-
terials in the EAG and NSF dominated areas to consol-
idated sandstones and shalestone materials. Thus, the
protection capacity offered by the overlying materials to
the aquifer varies from weak to strong depending on the
composition of the overlying materials that in many
cases, depends on the paleo-tectonic events of the area.
The weakly–fairly protected aquifers with IEC values
varying from 0.1 to ~0.4 S were dominant in locations
where fractured shales and other detrital materials domi-
nate the aquifer horizons. Impermeable consolidated
sandstones and/or shalestone materials overlie such aqui-
fers at very shallow depths. Most of the communities
where these aquifers abound are located on the elevated
parts of the study area. The overlying impermeable ma-
terials will reduce the rate of infiltration of contaminated
surface water and consequently increase their residence
time, thereby, strengthening surface runoff downhill.
The moderate–strongly protected aquifers are the
sandy/gravelly dominated aquifers in the EAG and NSF
areas characterised by IEC values that range between 1.1
and 2.6 S. The EAG and the NSF occupy the low lying
parts of the study area and aquifers are deeply buried at
depths below 40 m. Impermeable argillaceous materials
dominate the protective layers. Although locations where
these aquifers abound are areas where various forms of
farming practices including crop rotation that encourages
the use of artificial soil fertility enhancers is being prac-
ticed. The overlying clayey materials are thick enough to
naturally attenuate the contaminants and allow only good
quality water to get to the aquifer horizon. Finally, vul-
nerability mapping based on IEC and GOD techniques
are cost effective and efficient techniques for exploratory
assessment of aquifer protection and management as
these two are suited for regional investigations.
Acknowledgments The authors are grateful to the University of
Calabar, Calabar-Nigeria that provided the resources, which the
authors used in conducting the research. The contributions and
suggestions from the anonymous reviewers are gratefully
acknowledged.
References
Akpan, A. E., Ugbaja, A. N., & George, N. J. (2013). Integrated
geophysical, geochemical and hydrogeological investigation
of shallow groundwater resources in parts of the Ikom-
Mamfe Embayment and the adjoining areas in Cross River
State, Nigeria. Journal of Environmental Earth Sciences, 70,
1435–1456.
Aller, L, Bennet, T, Lehr, J.H., Petty, R.J., & Hackett, G. (1987).
DRASTIC: a standardized system for evaluating ground
water pollution potential using hydrogeologic settings. US
EPA, 600/2-87–035.
Almasri, M. N. (2008). Assessment of intrinsic vulnerability to
contamination for Gaza coastal aquifer, Palestine. Journal of
Environmental Management, 88, 577–593.
Benkhelil, M. G., Ponsard, J. F., & Saugy, L. (1975). The Bornu-
Benue Trough, the Niger Delta and its Offshore: Tectono-
sedimentary reconstruction during the Cretaceous and
Tertiary from geophysical data and geology. In C. A.
Kogbe (Ed.), Geology of Nigeria (pp. 277–309). Lagos:
Elizabethan Press.
Braga, A. C., Filho, W. M., & Dourado, J. C. (2006). Resistivity
(DC) method applied to aquifer protection studies. Revista
Brasileira de Geofisica, 24(4), 573–581.
Casas, A., Himi, M., Diaz, Y., Pinto, V., Font, X., & Tapias, J. C.
(2008). Assessing aquifer vulnerability to pollutants by elec-
trical resistivity tomography (ERT) at a nitrate vulnerable
zone in NE Spain. Environmental Geology, 54, 515–520.
Chambers, J. E., Wilkinson, P. B., Kuras, O., Ford, J. R., Gunn, D.
A., Meldrum, P. I., Pennington, C. V. L., Weller, A. L.,
Hobbs, P. R. N., & Ogilvy, R. D. (2011). Three-
dimensional geophysical anatomy of an active landslide in
Lias Group mudrocks, Cleveland basin, UK.
Geomorphology, 125(4), 472–484.
Civita, M., & De Maio, M. (1997). SINTACS Un sistema
parametricoper la valutazione e la cartografia per la
valutazione della vulnerabilit’a degli acquiferi
all’inquinamento, Metodologia e automazione. Bologna:
Pitagora Ed. 191.
Conrad, J., Hughes, S. & Weaver, J. (2002). Map production. In
Zaporozec, A. (Ed.), Groundwater contamination inventory:
a methodological guide (pp. 75-98). International
Hydrological Programme-VI, No. 2, UNESCO.
de Groot-Hedlin, C., & Constable, S. (1990). Occam’s inversion to
generate smooth, two dimensional models from
magnetotelluric data. Geophysics, 55, 1613–1624.
Dobrin, M. B., & Savit, C. H. (1988). Introduction to geophysical
prospecting (4th ed.). New York: McGraw-Hill Book
Company.
Draoui, M., Vias, J., Andreo, B., Targuist, K., & Stitou el MessarI,
J. (2007). A comparative study of four vulnerability mapping
methods in a detritic aquifer under Mediterranean climatic
conditions. Environmental Geology, 54, 455–463.
Ducci, D., & Sellerino, M. (2012). Vulnerability mapping of
groundwater contamination based on 3D lithostratigraphical
models of porous aquifers. Journal of Science of the Total
Environment, 447, 315–322.
Ebong, E. D. (2014). Hydrogeophysical and Physco-chemical
investigation of the Presbyterian Primary School Ekureku
Be Water borehole, Ekureku, Abi Local Government Area,
156 Page 16 of 18 Environ Monit Assess (2015) 187: 156
17. Cross River State. Unpublished Technical Report submitted
to Cross River State Community Development and Water
Supply Agency.
Ebong, E. D., Akpan, A. E., & Onwuegbuche, A. A. (2014).
Estimation of geohydraulic parameters from fractured shales
and sandstone aquifers of Abi (Nigeria) using electrical re-
sistivity and hydrogeologic measurements. Journal of
African Earth Sciences, 96, 99–109.
Edet, A. E. (2014). An aquifer vulnerability assessment of the
Benin Formation aquifer, Calabar, southeastern Nigeria,
using DRASTIC and GIS approach. Journal of
Environmental Earth Sciences, 71(4), 1747–1765.
Edet, A. E., & Okereke, C. S. (2002). Delineation of shallow
groundwater aquifers in the Coastal Plain Sands area
(Southern Nigeria) using surface resistivity and
hydrogeological data. Journal of African Earth Sciences,
35, 433–443.
Egboka, B. C. E., & Okpoko, E. I. (1984). Gully erosion in the
Agulu-Nanka region of Anambra State, Nigeria. Changes in
African Hydrology and Water Resources (Proceedings of the
Harare Symposium, July 1984). IAHS Publication No 144.
Egboka, B. C., & Uma, K. O. (1986). Hydrogeochemistry, con-
taminant transport and Tectonic effects in the Okposi-Uburu
salt lake area of Imo state, Nigeria. Hydrological Science
Journal, 31(2), 205–221.
Ekwueme, B. N., Nyong, E. E., & Petters, S. W. (1995).
Geological excursion guide book to Oban Massif.
Southeastern Nigeria: Calabar Flank and Mamfe
Embayment.
Eseme, E., Agyingi, C. M., & Foba-Tendo, J. (2002).
Geochemistry and genesis of brine emanations from
Cretaceous strata of the Mamfe Basin, Cameroon. Journal
of African Earth Sciences, 35, 467–476.
Ezzy, T. R., Cox, M., O’Rourke, A. J., & Huftile, G. (2006).
Groundwater flow modeling within a coastal alluvial plain
setting using a high-resolution hydrofacies approach: Bells
Creek plain, Australia. Hydrogeology Journal, 14, 675–688.
Foster, S. (1987). Fundamental concepts in aquifer vulnerability,
pollution risk and protection strategy. In W. Van
Duijvenbooden & H. G. Van-Waegeningh (Eds.),
Vulnerability of soil and groundwater to pollutants (pp. 69–
86). The Hague: Hydrological Research.
Foster, S. S. D., Hirata, R., Gomes, D., D'Elia, M., & Paris, M.
(2002). Groundwater quality protection: a guide for water
utilities, municipal authorities and environment agencies
(secondth ed.). Washington, DC: World Bank.
Fraga, C. M., Fernandes, L. F. S., Pacheco, F. A. L., Reis, C., &
Moura, J. P. (2013). Exploratory assessment of groundwater
vulnerability to pollution in the Sordo River Basin, Northeast
of Portugal. REM: R. Esc. Minas, Ouro Preto, 66(1), 49–58.
Freeze, R. A., & Cherry, J. A. (1979). Groundwater. Englewood
Cliffs. New Jersey: Prentice-Hall Inc. 604 p.
Gemail, K. S., El-Shishtawy, A. M., El-Alfy, M., Ghoneim, M. F.,
& Abd El-Bary, M. (2011). Assessment of aquifer vulnera-
bility to industrial waste water using resistivity measure-
ments. A case study along El-Gharbyia main drain, Nile
Delta, Egypt. Journal of Applied Geophysics, 75, 140–150.
Gogu, R. C., & Dassargues, A. (2000). Current trends and future
challenges in groundwater vulnerability assessment using
overlay and index methods. Environmental Geology, 39,
549–559.
Henriet, J. P. (1976). Direct applications of the Dar Zarrouk
parameters in ground water surveys. Geophysical
Prospecting, 24, 344–353.
Jassim, F. A., & Altaany, F. A. (2013). Image interpolation using
Kriging technique for spatial data. Canadian Journal on
Image Processing and Computer Vision, 4(2), 16–21.
Javadi, S., Kavehkar, N., Mousavizadeh, M. H., & Mohammadi,
K. (2011). Modification of DRASTIC model to map ground-
water vulnerability to pollution using nitrate measurements in
agricultural areas. Journal of Agricultural Science and
Technology, 13(2), 239–249.
Keller, G. V., & Frischknecht, F. C. (1966). Electrical methods in
geophysical prospecting. Oxford: Pergamon Press. 519 p.
Kirsch, R., Sengpiel, K., & Voss, W. (2003). The use of electrical
conductivity mapping in the definition of an aquifer vulner-
ability index. Near Surface Geophysics, 1, 3–20.
Kirsch, R. (2006). Groundwater geophysics: a tool for hydrogeol-
ogy. Springer-Verlag Berlin Hendelberg. 493p.
Leone, A., Ripa, M. N., Uricchio, V., Dek, L., & Vargay, Z. (2009).
Vulnerability and risk evaluation of agricultural nitrogen
pollution for Hungary’s main aquifer using DRASTIC and
GLEAMS models. Journal of Environmental Management,
90(10), 2969–2978.
Loke, M. H., & Barker, R. D. (1996). Practical techniques for rapid
least-squares inversion of apparent resistivity pseudosections
using a quasi-Newton method. Geophysical Prospecting, 44,
131–152.
Loke, M. H., Acworth, I., & Dahlin, T. (2003). A comparison of
smooth and blocky inversion methods in 2D electrical imag-
ing surveys. Exploration Geophysics, 34, 182–187.
Maillet, R. (1947). The fundamental equations of electric
prospecting. Geophysics 12, 529–556.
Mhomho Technologies & Environmental Services Ltd (2013).
Drilling, construction of a one unit motorised water supply
borehole and water quality analyses in Agbara-Ekureku. A
Technical Report No. 123, pp. 23.
Murat, R. C. (1972). Stratigraphy and Paleogeography of the
cretaceous and lower tertiary in southern Nigeria. In T. F. J.
Dessauvagie & A. J. Whiteman (Eds.), African geology (pp.
251–266). Ibadan: Univ. Press, Ibadan.
Neshat, A., Pradhan, B., Pirasteh, S., & Shafri, H. Z. M. (2013).
Estimating groundwater vulnerability to pollution using a
modified DRASTIC model in the Kerman agricultural area,
Iran. Environmental Earth Sciences. doi:10.1007/s12665-
013-2690-7.
Niwas, S., & Singhal, D. C. (1981). Estimation of aquifer trans-
missivity from Dar Zarrouck parameters in porous media.
Journal of Hydrology, 50, 393–399.
Odigi, M. I., & Amajor, L. C. (2009). Geochemical characteriza-
tion of Cretaceous sandstones from the Southern Benue
Trough, Nigeria. Chinese Journal of Geochemistry, 28,
044–054.
Offodile, M. E. (1975). A review of the geology and Cretaceous of
the Benue Valley. In C. A. Kogbe (Ed.), Geology of Nigeria
(pp. 375–376). Lagos: Elizabethen Press.
Okereke, C. S., Esu, E. O., & Edet, A. E. (1998). Determination of
potential groundwater sites using geological and geophysical
techniques in the Cross River State, southeastern Nigeria.
Journal of African Earth Sciences, 27(1), 149–163.
Okiongbo, K. S., & Akpofure, E. (2012). Determination of aquifer
properties and groundwater vulnerability mapping using
Environ Monit Assess (2015) 187: 156 Page 17 of 18 156
18. geoelectric method in Yenagoa City and its environs in
Bayelsa State, South South Nigeria. Journal of Water
Resource and Protection, 4, 354–362.
Olayinka, A. I., & Yaramanci, U. (2000). Assessment of the
reliability of 2D inversion of apparent resistivity data.
Geophysical Prospecting, 48(2), 293–316.
Onwualu, J. N., Ukaegbu, V. U., & Okengwu, K. O. (2012).
Source region inhomogeneity in igneous suite of Ishiagu,
Southern Benue Trough, Nigeria. Archives of Applied
Science Research, 4(2), 923–934.
Orellana, E., & Mooney, A. M. (1966). Master curve and tables
for vertical electrical sounding over layered structures.
Escuela, Spain: Interciencia.
Perles Roselló, M. J., Vías Martínez, J. M., & Andreo Navarro, B.
(2009). Vulnerability of human environment to risk: case of
groundwater contamination risk. Environment International,
3, 325–335.
Petters, S. W. (1989). A regional hydrogeological study of rural
water supply options for planning and implementation of
phase II rural water programme in Cross River State.
Unpublished Technical Report submitted to DFFRI, Cross
River State, pp 97.
Raju, N. J., & Reddy, T. V. K. (1998). Fracture pattern and
electrical resistivity studies for groundwater exploration.
Environmental Geology, 34(2–3), 175–182.
Reijers, T. J. A., & Nwajide, C. S., (1998). Geology of the
Southern Anambra Basin. Unpublished Report for Chevron
Nigeria Limited, Anambra Basin Field Course, p. 66.
Rijkswaterstaat, (1969). Standard Graphs for Resistivity
Prospecting, European Association of Exploration
Geophysicists, The Netherlands, The Hague.
Sharma, S. P., & Baranwal, V. C. (2005). Delineation of
groundwater-bearing fracture zones in a hard rock integrating
very low frequency electromagnetic and resistivity data.
Journal of Applied Geophysics, 57, 155–166.
Sinkevich, M. G., Walter, M. T., Lembo, A. J., Jr., Richards, B. K.,
Peranginangin, N., Aburime, S. A., & Steenhuis, T. S.
(2005). A GIS-based ground water contamination risk as-
sessment tool for pesticides. Ground Water Monitoring &
Remediation, 25(4), 82–91.
Sorensen, K. I., Auken, E., Christensen, N., & Pellerin, L. (2005).
An integrated approach for hydrogeophysical investigations:
new technologies and a case history. In D. K. Bulter (Ed.),
Near-surface Geophysics (pp. 585–597). Tulsa: Society of
Exploration Geophysicists.
Ukaegbu, V. U., & Akpabio, I. O. (2009). Geology and stratigra-
phy of middle cretaceous sequences Northeast of Afikpo
Basin, Lower Benue Trough, Nigeria. Pacific Journal of
Science and Technology, 103, 518–256.
Van Beers, W. C. M., & Kleijnen, J. P. C. (2003). Kriging for
interpolation in random simulation. Journal of Operational
Research Society, 54, 255–262.
Van Stempvoort, D., Ewert, L., & Wassenaar, L. A. (1992). A
method for groundwater protection mapping in the Prairie
Provinces of Canada, Canada, PPWB Report No. 114.
Saskatoon: National Hydreogeology Research Institute.
Vender Velpen, B. P. A. (1988). A computer processing package
for D.C. Resistivity interpretation for an IBM compatibles,
ITC JouR, Natherlands Vol-4.
Vrba, J., & Zaporozec, A. (1994). Guidebook on mapping ground-
water vulnerability. Verlag Heinz Heise, Hannover, Germany,
International contributions to hydrogeology, 16, p 131.
Waskom, R. M. (1994). Best management practices for nitrogen
fertilization. Bulletin #XCM-172, University Cooperative
Extension, Colorado State University.
Wilkinson, P. B., Meldrum, P. I., Kuras, O., Chambers, J. E.,
Holyoake, S. J., & Ogilvy, R. D. (2010). High-resolution
electrical resistivity tomography monitoring of a tracer test
in a confined aquifer. Journal of Applied Geophysics, 70,
268–276.
Yadav, G. S., & Singh, S. K. (2007). Integrated resistivity surveys
for delineation of fractures for ground water exploration in
hard rock areas. Journal of Applied Geophysics, 62(3), 301–
312.
Yadav, S. N., & Wall, D. B. (1998). Benefit-cost analysis of best
management practices implemented to control nitrate con-
tamination of groundwater. Water Resources Research,
34(3), 497–504.
Yin, L., Zhang, E., Wang, X., Wenninger, J., Dong, J., Guo, L., &
Huang, J. (2012). A GIS-based DRASTIC model for
assessing groundwater vulnerability in the Ordos Plateau,
China. Environmental Earth Sciences, 69(1), 171–185.
156 Page 18 of 18 Environ Monit Assess (2015) 187: 156