SlideShare a Scribd company logo
AMESA-M

Total Mercury Analyser
Monitoring system for fully-automatic and
continuous mercury analysis in smoke gas
(without wet chemistry)
Already MCERTS and TÜV accredited for continuous dioxin and furan

KEYBENEFITS

monitoring, the AMESA - M has been adapted for mercury monitoring.

•

Maintenance-free (6 months) dry

AMESA - M extracts a sample from the flue gas stream under volume

reactor

proportional conditions.

•
•
•
•

Consisting of a sample probe assembly and a control cabinet, the

High operational safety
Easy maintenance

Internal Data Logging Functionality

Low cross sensitivities

The unit can store up to a four week period of sampling data which is

Thermal mass flow meter to control 	 	

then available to download via a USB flash drive. Analysis can be achieved

mass flow independent of gas &

with an onsite analyser or a certified laboratory.

pressure
Dry gas meter to determine sample 	 	

Measuring Principle

volume

The sample gas is converted into mercury vapour by a combination of
thermal and dry chemical treatment. This is then continuously
measured in a photometer. Probe gas flow is measured after a gas cooler
at 2°C. The concentration is calculated and displayed as dry flue gas.

“

Providing continuous Mercury
monitoring, The AMESA - M is suited
for audit & control purposes

“

•
TECHNICALSPECIFICATION
APPLICATIONS

• Waste incinerations	
• Sewage sludge incineration
• Contaminated soil burning plants
• Mercury mines and refineries
• Fluorescent light bulb recycling plants
MEASUREMENT PRINCIPLE

• Measurements: total mercury
• Measuring ranges 0–45 to 0–500 μg/Nm³
• Measuring principle: UV-absorption

POWER

• Measuring outputs: 2 x 0 / 4–20 mA/500 Ohm
• Digital outputs: 4 relay outputs, permissible load 250 V, 	
100 VA

• Digital inputs: 1 potential free outputs
• Supply voltage: 230 VAC, 50 Hz, 1200 VA
		

sample probe: 650 VA

		

sample line: 100 VA/m

SPAN & DRIFT

• Accuracy: <1% of measuring range	
• Detection limit: <1 μg/Nm³
• Reference point drift: <2% of measuring range/month
• Zero point drift: automatic zero correction

TEMPERATURE & PRESSURE

• Flue gas temperature: 0–250 °C	
• Flue gas pressure: -50 up to +50 hPa
• Ambient temperature: +5 bis +30°C

APPROVALS

• MCERTS 	
• TÜV Certified

PHYSICAL

• Dimensions: cabinet 1600 x 800 x 500 mm (H x W x D)
• Weight: 220 kg
• Duct diameter: >0.5 m

Complete Project Solutions
Our complete project solutions are developed to assist you
in IED compliance. We achieve this through;

•
•
•
•
•

Expert consultancy
Project management
In-house project design & build
Installation & commissioning
After product service & support

11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com

Cert No. 996
ISO 9001

More Related Content

What's hot

542 Programmable Gas Analyser
542 Programmable Gas Analyser542 Programmable Gas Analyser
542 Programmable Gas Analyser
SystechIllinois
 
Oxygen analyser
Oxygen analyserOxygen analyser
Oxygen analyser
Jerry John
 
Current Advances in Instrumentation of Protein Analyzers
Current Advances in Instrumentation of Protein AnalyzersCurrent Advances in Instrumentation of Protein Analyzers
Current Advances in Instrumentation of Protein Analyzers
Elementar Analysensysteme GmbH
 
ABB CEMS Datasheet ABB cems solution and products information
ABB CEMS Datasheet ABB cems solution and products informationABB CEMS Datasheet ABB cems solution and products information
ABB CEMS Datasheet ABB cems solution and products information
ENVIMART
 
Techniques for measuring ammonia emissions through manure management systems
Techniques for measuring ammonia emissions through manure management systemsTechniques for measuring ammonia emissions through manure management systems
Techniques for measuring ammonia emissions through manure management systems
PMAS Arid Agriculture University Rawalpindi, Pakistan
 
Soot-free combustion of diesel, gasoline and other organic liquids
Soot-free combustion of diesel, gasoline and other organic liquidsSoot-free combustion of diesel, gasoline and other organic liquids
Soot-free combustion of diesel, gasoline and other organic liquids
Elementar Analysensysteme GmbH
 
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas AnalyzerMRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
Diamond Scientific
 
SWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas AnalyzerSWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas Analyzer
Diamond Scientific
 
Advances in High Temperature Oxygen Analysis
Advances in High Temperature Oxygen AnalysisAdvances in High Temperature Oxygen Analysis
Advances in High Temperature Oxygen Analysis
Elementar Analysensysteme GmbH
 
MRU AMPRO 2000 Gold| Handheld Combustion Gas Analyzer
MRU AMPRO 2000 Gold| Handheld Combustion Gas AnalyzerMRU AMPRO 2000 Gold| Handheld Combustion Gas Analyzer
MRU AMPRO 2000 Gold| Handheld Combustion Gas Analyzer
Diamond Scientific
 
Continuous Emissions Monitoring presentation by ET
Continuous Emissions Monitoring presentation by ETContinuous Emissions Monitoring presentation by ET
Continuous Emissions Monitoring presentation by ET
Enviro Technology Services Plc
 
Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...
Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...
Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...
Xylem Inc.
 
Die einfache Art der Kohlenstoff- und Schwefelanalyse
Die einfache Art der Kohlenstoff- und SchwefelanalyseDie einfache Art der Kohlenstoff- und Schwefelanalyse
Die einfache Art der Kohlenstoff- und Schwefelanalyse
Elementar Analysensysteme GmbH
 
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
Testing and Troubleshooting 4-20 mA Control Loops  Presented by Fluke and Tra...Testing and Troubleshooting 4-20 mA Control Loops  Presented by Fluke and Tra...
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
Transcat
 
presentation wisa 2010 15 April 2010 2
presentation wisa 2010 15 April 2010 2presentation wisa 2010 15 April 2010 2
presentation wisa 2010 15 April 2010 2Werner Rössle
 

What's hot (20)

542 Programmable Gas Analyser
542 Programmable Gas Analyser542 Programmable Gas Analyser
542 Programmable Gas Analyser
 
Oxygen analyser
Oxygen analyserOxygen analyser
Oxygen analyser
 
Current Advances in Instrumentation of Protein Analyzers
Current Advances in Instrumentation of Protein AnalyzersCurrent Advances in Instrumentation of Protein Analyzers
Current Advances in Instrumentation of Protein Analyzers
 
Specifications aas
Specifications aasSpecifications aas
Specifications aas
 
ABB CEMS Datasheet ABB cems solution and products information
ABB CEMS Datasheet ABB cems solution and products informationABB CEMS Datasheet ABB cems solution and products information
ABB CEMS Datasheet ABB cems solution and products information
 
Techniques for measuring ammonia emissions through manure management systems
Techniques for measuring ammonia emissions through manure management systemsTechniques for measuring ammonia emissions through manure management systems
Techniques for measuring ammonia emissions through manure management systems
 
Soot-free combustion of diesel, gasoline and other organic liquids
Soot-free combustion of diesel, gasoline and other organic liquidsSoot-free combustion of diesel, gasoline and other organic liquids
Soot-free combustion of diesel, gasoline and other organic liquids
 
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas AnalyzerMRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
 
SWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas AnalyzerSWG 100 BIO EX | Stationary Biogas Analyzer
SWG 100 BIO EX | Stationary Biogas Analyzer
 
BENCHMARK linecard 2016
BENCHMARK linecard 2016BENCHMARK linecard 2016
BENCHMARK linecard 2016
 
Advances in High Temperature Oxygen Analysis
Advances in High Temperature Oxygen AnalysisAdvances in High Temperature Oxygen Analysis
Advances in High Temperature Oxygen Analysis
 
Humidity Sensor
Humidity SensorHumidity Sensor
Humidity Sensor
 
MRU AMPRO 2000 Gold| Handheld Combustion Gas Analyzer
MRU AMPRO 2000 Gold| Handheld Combustion Gas AnalyzerMRU AMPRO 2000 Gold| Handheld Combustion Gas Analyzer
MRU AMPRO 2000 Gold| Handheld Combustion Gas Analyzer
 
Instruments chns overview_2011
Instruments chns overview_2011Instruments chns overview_2011
Instruments chns overview_2011
 
Continuous Emissions Monitoring presentation by ET
Continuous Emissions Monitoring presentation by ETContinuous Emissions Monitoring presentation by ET
Continuous Emissions Monitoring presentation by ET
 
fire & gas detection system
fire & gas detection systemfire & gas detection system
fire & gas detection system
 
Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...
Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...
Process Monitoring and Automation of Water Resource Recovery Facilities | IQ ...
 
Die einfache Art der Kohlenstoff- und Schwefelanalyse
Die einfache Art der Kohlenstoff- und SchwefelanalyseDie einfache Art der Kohlenstoff- und Schwefelanalyse
Die einfache Art der Kohlenstoff- und Schwefelanalyse
 
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
Testing and Troubleshooting 4-20 mA Control Loops  Presented by Fluke and Tra...Testing and Troubleshooting 4-20 mA Control Loops  Presented by Fluke and Tra...
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
 
presentation wisa 2010 15 April 2010 2
presentation wisa 2010 15 April 2010 2presentation wisa 2010 15 April 2010 2
presentation wisa 2010 15 April 2010 2
 

Similar to Amesa mercury sorbent trap system datasheet

Mir ft datasheet
Mir ft datasheetMir ft datasheet
Mir ft datasheeta1-cbiss
 
Mir is datasheet
Mir is datasheetMir is datasheet
Mir is datasheeta1-cbiss
 
Envea cems emission- monitoring-catalogue-en_s
Envea cems emission- monitoring-catalogue-en_sEnvea cems emission- monitoring-catalogue-en_s
Envea cems emission- monitoring-catalogue-en_s
Pompilia Sopco
 
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared SpectroscopyProcess Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Metrohm USA
 
Photometric sensor for SAC or nitrate measurement
Photometric sensor for SAC or nitrate measurementPhotometric sensor for SAC or nitrate measurement
Photometric sensor for SAC or nitrate measurement
Edress Hauser: Flow Meter, Level, Pressure, Temperature
 
Dissolved Oxygen Sensors-Oxymax COS22/22D
Dissolved Oxygen Sensors-Oxymax COS22/22DDissolved Oxygen Sensors-Oxymax COS22/22D
Dissolved Oxygen Sensors-Oxymax COS22/22D
Edress Hauser: Flow Meter, Level, Pressure, Temperature
 
Qualification of high performance liquid chromatography
Qualification of high performance liquid chromatographyQualification of high performance liquid chromatography
Qualification of high performance liquid chromatography
srikrupa institute of pharmaceutical analysis
 
Types of Industrial Process Analyzers
Types of Industrial Process AnalyzersTypes of Industrial Process Analyzers
Types of Industrial Process AnalyzersAttiya Rehman
 
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygenOxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
ENVIMART
 
Combination of pH and ORP electrode
Combination of pH and ORP electrodeCombination of pH and ORP electrode
Combination of pH and ORP electrode
Edress Hauser: Flow Meter, Level, Pressure, Temperature
 
MRU SWG 100 Fixed Biogas Analyzer
MRU SWG 100 Fixed Biogas Analyzer MRU SWG 100 Fixed Biogas Analyzer
MRU SWG 100 Fixed Biogas Analyzer
Diamond Scientific
 
CEMSI Cement Solutions
CEMSI Cement SolutionsCEMSI Cement Solutions
CEMSI Cement Solutions
CEM Specialties Inc.
 
UV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheetUV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheet
ENVIMART
 
In Situ Oxygen Transmitter For Combustion Monitoring
In Situ Oxygen Transmitter For Combustion MonitoringIn Situ Oxygen Transmitter For Combustion Monitoring
In Situ Oxygen Transmitter For Combustion Monitoring
Hile Controls of Alabama, Inc.
 
CEMS pre 1.pdf
CEMS pre 1.pdfCEMS pre 1.pdf
CEMS pre 1.pdf
Harinath Gupta
 
pH electrodes-pH sensors CPS41
pH electrodes-pH sensors CPS41pH electrodes-pH sensors CPS41
Dissolved Oxygen Sensors-Oxymax COS51D
Dissolved Oxygen Sensors-Oxymax COS51DDissolved Oxygen Sensors-Oxymax COS51D
Dissolved Oxygen Sensors-Oxymax COS51D
Edress Hauser: Flow Meter, Level, Pressure, Temperature
 
Gases
GasesGases
Gases
ECRD2015
 
Monitoring of Gaseous Pollutants
Monitoring of Gaseous PollutantsMonitoring of Gaseous Pollutants
Monitoring of Gaseous Pollutants
ECRD IN
 
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygenOxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
ENVIMART
 

Similar to Amesa mercury sorbent trap system datasheet (20)

Mir ft datasheet
Mir ft datasheetMir ft datasheet
Mir ft datasheet
 
Mir is datasheet
Mir is datasheetMir is datasheet
Mir is datasheet
 
Envea cems emission- monitoring-catalogue-en_s
Envea cems emission- monitoring-catalogue-en_sEnvea cems emission- monitoring-catalogue-en_s
Envea cems emission- monitoring-catalogue-en_s
 
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared SpectroscopyProcess Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
 
Photometric sensor for SAC or nitrate measurement
Photometric sensor for SAC or nitrate measurementPhotometric sensor for SAC or nitrate measurement
Photometric sensor for SAC or nitrate measurement
 
Dissolved Oxygen Sensors-Oxymax COS22/22D
Dissolved Oxygen Sensors-Oxymax COS22/22DDissolved Oxygen Sensors-Oxymax COS22/22D
Dissolved Oxygen Sensors-Oxymax COS22/22D
 
Qualification of high performance liquid chromatography
Qualification of high performance liquid chromatographyQualification of high performance liquid chromatography
Qualification of high performance liquid chromatography
 
Types of Industrial Process Analyzers
Types of Industrial Process AnalyzersTypes of Industrial Process Analyzers
Types of Industrial Process Analyzers
 
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygenOxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
 
Combination of pH and ORP electrode
Combination of pH and ORP electrodeCombination of pH and ORP electrode
Combination of pH and ORP electrode
 
MRU SWG 100 Fixed Biogas Analyzer
MRU SWG 100 Fixed Biogas Analyzer MRU SWG 100 Fixed Biogas Analyzer
MRU SWG 100 Fixed Biogas Analyzer
 
CEMSI Cement Solutions
CEMSI Cement SolutionsCEMSI Cement Solutions
CEMSI Cement Solutions
 
UV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheetUV400-ATEX online water analyser-tethys datasheet
UV400-ATEX online water analyser-tethys datasheet
 
In Situ Oxygen Transmitter For Combustion Monitoring
In Situ Oxygen Transmitter For Combustion MonitoringIn Situ Oxygen Transmitter For Combustion Monitoring
In Situ Oxygen Transmitter For Combustion Monitoring
 
CEMS pre 1.pdf
CEMS pre 1.pdfCEMS pre 1.pdf
CEMS pre 1.pdf
 
pH electrodes-pH sensors CPS41
pH electrodes-pH sensors CPS41pH electrodes-pH sensors CPS41
pH electrodes-pH sensors CPS41
 
Dissolved Oxygen Sensors-Oxymax COS51D
Dissolved Oxygen Sensors-Oxymax COS51DDissolved Oxygen Sensors-Oxymax COS51D
Dissolved Oxygen Sensors-Oxymax COS51D
 
Gases
GasesGases
Gases
 
Monitoring of Gaseous Pollutants
Monitoring of Gaseous PollutantsMonitoring of Gaseous Pollutants
Monitoring of Gaseous Pollutants
 
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygenOxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos51 d endress+hauser datasheet-measurement of the dissolved oxygen
 

More from a1-cbiss

Gas Detector Tube List
Gas Detector Tube ListGas Detector Tube List
Gas Detector Tube List
a1-cbiss
 
a1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochurea1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochure
a1-cbiss
 
a1-cbiss Gastec Tubes
a1-cbiss Gastec Tubesa1-cbiss Gastec Tubes
a1-cbiss Gastec Tubes
a1-cbiss
 
Continuous Emissions Monitoring
Continuous Emissions MonitoringContinuous Emissions Monitoring
Continuous Emissions Monitoring
a1-cbiss
 
Tango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection DatasheetTango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection Datasheet
a1-cbiss
 
Oldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector DatasheetOldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector Datasheet
a1-cbiss
 
Mx43 Gas Detector
Mx43 Gas DetectorMx43 Gas Detector
Mx43 Gas Detector
a1-cbiss
 
Refrigeration Brochure
Refrigeration BrochureRefrigeration Brochure
Refrigeration Brochure
a1-cbiss
 
Innova 1412 Gas Monitor
Innova 1412 Gas MonitorInnova 1412 Gas Monitor
Innova 1412 Gas Monitor
a1-cbiss
 
Oldham OLCT80 Gas Detector
Oldham OLCT80 Gas DetectorOldham OLCT80 Gas Detector
Oldham OLCT80 Gas Detector
a1-cbiss
 
MSA Ultrasonic Gas Detector
MSA Ultrasonic Gas DetectorMSA Ultrasonic Gas Detector
MSA Ultrasonic Gas Detector
a1-cbiss
 
Odalog RTx Datasheet
Odalog RTx DatasheetOdalog RTx Datasheet
Odalog RTx Datasheet
a1-cbiss
 
Egas datasheet
Egas datasheetEgas datasheet
Egas datasheeta1-cbiss
 
Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)a1-cbiss
 
Olct10 datasheet
Olct10 datasheetOlct10 datasheet
Olct10 datasheeta1-cbiss
 
Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0a1-cbiss
 
Monicon ir80 co2 gas detector
Monicon ir80 co2 gas detectorMonicon ir80 co2 gas detector
Monicon ir80 co2 gas detectora1-cbiss
 
Detect f 2013 datasheet 0
Detect f 2013 datasheet 0Detect f 2013 datasheet 0
Detect f 2013 datasheet 0a1-cbiss
 
Genie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheetGenie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheeta1-cbiss
 
Oda log l2 datasheet
Oda log l2 datasheetOda log l2 datasheet
Oda log l2 datasheeta1-cbiss
 

More from a1-cbiss (20)

Gas Detector Tube List
Gas Detector Tube ListGas Detector Tube List
Gas Detector Tube List
 
a1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochurea1-cbiss Gas Detectors Brochure
a1-cbiss Gas Detectors Brochure
 
a1-cbiss Gastec Tubes
a1-cbiss Gastec Tubesa1-cbiss Gastec Tubes
a1-cbiss Gastec Tubes
 
Continuous Emissions Monitoring
Continuous Emissions MonitoringContinuous Emissions Monitoring
Continuous Emissions Monitoring
 
Tango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection DatasheetTango tx1 Gas Detection Datasheet
Tango tx1 Gas Detection Datasheet
 
Oldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector DatasheetOldham OLCT100 Gas Detector Datasheet
Oldham OLCT100 Gas Detector Datasheet
 
Mx43 Gas Detector
Mx43 Gas DetectorMx43 Gas Detector
Mx43 Gas Detector
 
Refrigeration Brochure
Refrigeration BrochureRefrigeration Brochure
Refrigeration Brochure
 
Innova 1412 Gas Monitor
Innova 1412 Gas MonitorInnova 1412 Gas Monitor
Innova 1412 Gas Monitor
 
Oldham OLCT80 Gas Detector
Oldham OLCT80 Gas DetectorOldham OLCT80 Gas Detector
Oldham OLCT80 Gas Detector
 
MSA Ultrasonic Gas Detector
MSA Ultrasonic Gas DetectorMSA Ultrasonic Gas Detector
MSA Ultrasonic Gas Detector
 
Odalog RTx Datasheet
Odalog RTx DatasheetOdalog RTx Datasheet
Odalog RTx Datasheet
 
Egas datasheet
Egas datasheetEgas datasheet
Egas datasheet
 
Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)Refrigeration brochure sept 2012 (2)
Refrigeration brochure sept 2012 (2)
 
Olct10 datasheet
Olct10 datasheetOlct10 datasheet
Olct10 datasheet
 
Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0
 
Monicon ir80 co2 gas detector
Monicon ir80 co2 gas detectorMonicon ir80 co2 gas detector
Monicon ir80 co2 gas detector
 
Detect f 2013 datasheet 0
Detect f 2013 datasheet 0Detect f 2013 datasheet 0
Detect f 2013 datasheet 0
 
Genie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheetGenie 757 spot sampling assembly datasheet
Genie 757 spot sampling assembly datasheet
 
Oda log l2 datasheet
Oda log l2 datasheetOda log l2 datasheet
Oda log l2 datasheet
 

Amesa mercury sorbent trap system datasheet

  • 1. AMESA-M Total Mercury Analyser Monitoring system for fully-automatic and continuous mercury analysis in smoke gas (without wet chemistry) Already MCERTS and TÜV accredited for continuous dioxin and furan KEYBENEFITS monitoring, the AMESA - M has been adapted for mercury monitoring. • Maintenance-free (6 months) dry AMESA - M extracts a sample from the flue gas stream under volume reactor proportional conditions. • • • • Consisting of a sample probe assembly and a control cabinet, the High operational safety Easy maintenance Internal Data Logging Functionality Low cross sensitivities The unit can store up to a four week period of sampling data which is Thermal mass flow meter to control then available to download via a USB flash drive. Analysis can be achieved mass flow independent of gas & with an onsite analyser or a certified laboratory. pressure Dry gas meter to determine sample Measuring Principle volume The sample gas is converted into mercury vapour by a combination of thermal and dry chemical treatment. This is then continuously measured in a photometer. Probe gas flow is measured after a gas cooler at 2°C. The concentration is calculated and displayed as dry flue gas. “ Providing continuous Mercury monitoring, The AMESA - M is suited for audit & control purposes “ •
  • 2. TECHNICALSPECIFICATION APPLICATIONS • Waste incinerations • Sewage sludge incineration • Contaminated soil burning plants • Mercury mines and refineries • Fluorescent light bulb recycling plants MEASUREMENT PRINCIPLE • Measurements: total mercury • Measuring ranges 0–45 to 0–500 μg/Nm³ • Measuring principle: UV-absorption POWER • Measuring outputs: 2 x 0 / 4–20 mA/500 Ohm • Digital outputs: 4 relay outputs, permissible load 250 V, 100 VA • Digital inputs: 1 potential free outputs • Supply voltage: 230 VAC, 50 Hz, 1200 VA sample probe: 650 VA sample line: 100 VA/m SPAN & DRIFT • Accuracy: <1% of measuring range • Detection limit: <1 μg/Nm³ • Reference point drift: <2% of measuring range/month • Zero point drift: automatic zero correction TEMPERATURE & PRESSURE • Flue gas temperature: 0–250 °C • Flue gas pressure: -50 up to +50 hPa • Ambient temperature: +5 bis +30°C APPROVALS • MCERTS • TÜV Certified PHYSICAL • Dimensions: cabinet 1600 x 800 x 500 mm (H x W x D) • Weight: 220 kg • Duct diameter: >0.5 m Complete Project Solutions Our complete project solutions are developed to assist you in IED compliance. We achieve this through; • • • • • Expert consultancy Project management In-house project design & build Installation & commissioning After product service & support 11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com Cert No. 996 ISO 9001