The Horiba PG-250 is a portable multi-gas analyzer that can monitor up to 5 components: NOx, SO2, CO, CO2, and O2. It utilizes the same measurement principles as permanently installed CEMS. The instrument directly interfaces with a laptop and features built-in sample conditioning. An optional auxiliary cooler is available to condition samples with excess water vapor.
For efficient control of combustion and drying processes
Simultaneous or as individual measurement: the GM35 gas analyzer measures CO2, H2O and CO, or N2O, as well temperature and pressure – and it does this reliably, quickly, and economically. As an in-situ gas analyzer, the GM35 detects these gas components directly in the gas stream without gas sampling. Reliability, precision, and short response time of the GM35 offer a key advantage for efficient control loops in all CO and CO2-generating processes.
Vasthi Engineers are most popular Manufacturing industries in india. we are Supplying Dew Point Meters, Gas Analyzers and Gas Detectors for customer world wide.
For more details visit->http://www.vasthi.com/gas-analyzers/
Meet the demanding needs of high-purity water measurements and high-acid cation exchange applications with the Thermo Scientific™ Orion™ 2111XP Sodium Analyzer. This system offers unmatched reliability in analyzing critical sample streams throughout the power/steam generation and industrial water industry. It is an all-in-one system from one of the most trusted names in sodium monitoring.
The main focus within environmental analysis is the subject of water. Our instruments are used to carry out routine analysis of organic impurities in the water industry. Learn about our solutions for water analysis.
For efficient control of combustion and drying processes
Simultaneous or as individual measurement: the GM35 gas analyzer measures CO2, H2O and CO, or N2O, as well temperature and pressure – and it does this reliably, quickly, and economically. As an in-situ gas analyzer, the GM35 detects these gas components directly in the gas stream without gas sampling. Reliability, precision, and short response time of the GM35 offer a key advantage for efficient control loops in all CO and CO2-generating processes.
Vasthi Engineers are most popular Manufacturing industries in india. we are Supplying Dew Point Meters, Gas Analyzers and Gas Detectors for customer world wide.
For more details visit->http://www.vasthi.com/gas-analyzers/
Meet the demanding needs of high-purity water measurements and high-acid cation exchange applications with the Thermo Scientific™ Orion™ 2111XP Sodium Analyzer. This system offers unmatched reliability in analyzing critical sample streams throughout the power/steam generation and industrial water industry. It is an all-in-one system from one of the most trusted names in sodium monitoring.
The main focus within environmental analysis is the subject of water. Our instruments are used to carry out routine analysis of organic impurities in the water industry. Learn about our solutions for water analysis.
- Process effects of pre-reforming
- Process benefits of pre-reforming
- Effect of Pre-reformer Inlet Temp on Primary Reformer Efficiency
- Services for Pre-reforming
Pre-Reforming Problems
- Features: Impact of Sulfur
- High Temperature Operation
- Catalyst Deactivation
- Which is Better - High or Low Inlet Temperatures ?
- Pre Reformer Loading
- Pre-Reformer Installation
- Pre-reformer Startup
- Catalyst Drying
- Catalyst Heating
- Reduction
Industrial Temperature Calibration Selection Guide by Fluke CalibrationFluke Calibration
The Industrial Temperature Calibration Selection Guide includes information on:
Field metrology wells
Infrared calibrators
Handheld and field dry-wells
Micro-baths
Environmental monitoring
Thermometer readouts
Reference sensors Industrial temperature calibration selection guide Tools
Una soluzione efficiente e competitiva con un basso GWP - F. Flohr - DaikinCentro Studi Galileo
Convegno Europeo
IL PASSAGGIO AI REFRIGERANTI ALTERNATIVI:
IMPATTO SU IMPIANTI NUOVI ED ESISTENTI
Le Ultime Tecnologie nel Condizionamento e nella Refrigerazione; Sistemi, Attrezzatura, Componenti, Formazione e Certificazione; il Phase Down
15 marzo 2018 | 14.00 - 18.30
Mostra Convegno Expocomfort
Centro Congressi Stella Polare: Sala Sagittarius
Organizzato da ATF - Associazione Tecnici del Freddo
How to Calibrate an RTD Using a Dry Block Calibrator v2Transcat
Transcat and Ron Ainsworth of Fluke Calibration detail the steps and considerations necessary for the calibration of an RTD with a Dry Block Calibrator.
Elemental analysis provides critical information for the evaluation of soil fertility and the elucidation of nutrient cycles. The soil C/N ratio is an important parameter for judging soil fertility, S concentrations are connected to fertilizer inputs and atmospheric deposition, and C concentrations are indicative for soil organic matter content. Because soils are inhomogeneous by nature, sample amount plays in important role in their analysis. This webinar presents the dedicated solutions offered by Elementar for the elemental analysis of soils.
Hedland offers a complete line of over 15,000 variable area flow meters to measure oil, hydraulic oil, phosphate esters, water and water-based fluids, as well as air and other compressed gases.
Refrigeranti a basso GWP per il condizionamento e le pompe di calore - B. Bel...Centro Studi Galileo
Convegno Europeo
IL PASSAGGIO AI REFRIGERANTI ALTERNATIVI:
IMPATTO SU IMPIANTI NUOVI ED ESISTENTI
Le Ultime Tecnologie nel Condizionamento e nella Refrigerazione; Sistemi, Attrezzatura, Componenti, Formazione e Certificazione; il Phase Down
15 marzo 2018 | 14.00 - 18.30
Mostra Convegno Expocomfort
Centro Congressi Stella Polare: Sala Sagittarius
Organizzato da ATF - Associazione Tecnici del Freddo
Der von Elementar neu entwickelte inductar CS cube für die CS Analyse vereint hoch präzise Daten mit einem benutzerfreundlichen, sauberen und automatischen Analysenprozess. Entdecken Sie ein neues Level der Kohlenstoff- und Schwefelbestimmung in Metallen und anorganischen Materialien. Der neue inductar CS cube steckt voller innovativer und fortschrittlicher Ideen, um Ihre CS Analyse einfacher und zuverlässiger zu machen.
Weitere Informationen zum inductar CS cube erhalten Sie in unserem Webinar.
Temperature Calibration equipment for Thermcouple, RTDs, and PyrometersTempsens Instruments
Various types of Tempsens make temperature Calibration Equipment for calibration of temperature sensors accurately. Temperature sources and master sensors
Black body sources, Reference junction units, Dry block Calibrators, Stirred Liquid Baths, Cold Junction Compensation, AUTOCAL,
The webinar addresses all operators of a vario MAX N/CN cube. We pay attention to frequently asked questions regarding maintenance, method optimization and instrument parameters. Furthermore, we talk about typical sample matrices that can cause problems during the analysis and assist you to solve them.
Practical Analytical Instrumentation in On-line ApplicationsLiving Online
At the end of this workshop participants will be able to:
Recognise and efficiently troubleshoot a wide variety of industrial analytical measuring instruments
Describe the construction and operation of the most important analytical instruments
Define and explain relevant chemical terminology
Identify sample chemical formulae and symbols
Implement procedures for testing and calibration of analytical instruments
WHO SHOULD ATTEND?
Technicians
Senior operators
Instrumentation and control engineers
Electrical engineers
Project engineers
Design engineers
Process control engineers
Instrumentation sales engineers
Consulting ingenious
Electricians
Maintenance engineers
Systems engineers
MORE INFORMATION: http://www.idc-online.com/content/practical-analytical-instrumentation-line-applications-3
Elementar developed a CS analyzer which combines highly accurate data with easy to use, clean and automated processes. Experience the new level of carbon and sulfur determination in metals and inorganic materials. The new inductar CS cube is full of innovative and advanced ideas to make CS analysis more easy to use and more reliable.
MRU AMPRO 2000 GOLD is a powerful handheld gas analyzer suitable for monitoring combustion and industrial processes measure up to 7 gas components. Request FREE Quote Today.
MRU SWG 100 Fixed Biogas Analyzer is the rugged industrial analyzer to use with biogas & biomethane plants, landfill, water treatment as well as coal seam gas sites. Request a FREE quote today.
- Process effects of pre-reforming
- Process benefits of pre-reforming
- Effect of Pre-reformer Inlet Temp on Primary Reformer Efficiency
- Services for Pre-reforming
Pre-Reforming Problems
- Features: Impact of Sulfur
- High Temperature Operation
- Catalyst Deactivation
- Which is Better - High or Low Inlet Temperatures ?
- Pre Reformer Loading
- Pre-Reformer Installation
- Pre-reformer Startup
- Catalyst Drying
- Catalyst Heating
- Reduction
Industrial Temperature Calibration Selection Guide by Fluke CalibrationFluke Calibration
The Industrial Temperature Calibration Selection Guide includes information on:
Field metrology wells
Infrared calibrators
Handheld and field dry-wells
Micro-baths
Environmental monitoring
Thermometer readouts
Reference sensors Industrial temperature calibration selection guide Tools
Una soluzione efficiente e competitiva con un basso GWP - F. Flohr - DaikinCentro Studi Galileo
Convegno Europeo
IL PASSAGGIO AI REFRIGERANTI ALTERNATIVI:
IMPATTO SU IMPIANTI NUOVI ED ESISTENTI
Le Ultime Tecnologie nel Condizionamento e nella Refrigerazione; Sistemi, Attrezzatura, Componenti, Formazione e Certificazione; il Phase Down
15 marzo 2018 | 14.00 - 18.30
Mostra Convegno Expocomfort
Centro Congressi Stella Polare: Sala Sagittarius
Organizzato da ATF - Associazione Tecnici del Freddo
How to Calibrate an RTD Using a Dry Block Calibrator v2Transcat
Transcat and Ron Ainsworth of Fluke Calibration detail the steps and considerations necessary for the calibration of an RTD with a Dry Block Calibrator.
Elemental analysis provides critical information for the evaluation of soil fertility and the elucidation of nutrient cycles. The soil C/N ratio is an important parameter for judging soil fertility, S concentrations are connected to fertilizer inputs and atmospheric deposition, and C concentrations are indicative for soil organic matter content. Because soils are inhomogeneous by nature, sample amount plays in important role in their analysis. This webinar presents the dedicated solutions offered by Elementar for the elemental analysis of soils.
Hedland offers a complete line of over 15,000 variable area flow meters to measure oil, hydraulic oil, phosphate esters, water and water-based fluids, as well as air and other compressed gases.
Refrigeranti a basso GWP per il condizionamento e le pompe di calore - B. Bel...Centro Studi Galileo
Convegno Europeo
IL PASSAGGIO AI REFRIGERANTI ALTERNATIVI:
IMPATTO SU IMPIANTI NUOVI ED ESISTENTI
Le Ultime Tecnologie nel Condizionamento e nella Refrigerazione; Sistemi, Attrezzatura, Componenti, Formazione e Certificazione; il Phase Down
15 marzo 2018 | 14.00 - 18.30
Mostra Convegno Expocomfort
Centro Congressi Stella Polare: Sala Sagittarius
Organizzato da ATF - Associazione Tecnici del Freddo
Der von Elementar neu entwickelte inductar CS cube für die CS Analyse vereint hoch präzise Daten mit einem benutzerfreundlichen, sauberen und automatischen Analysenprozess. Entdecken Sie ein neues Level der Kohlenstoff- und Schwefelbestimmung in Metallen und anorganischen Materialien. Der neue inductar CS cube steckt voller innovativer und fortschrittlicher Ideen, um Ihre CS Analyse einfacher und zuverlässiger zu machen.
Weitere Informationen zum inductar CS cube erhalten Sie in unserem Webinar.
Temperature Calibration equipment for Thermcouple, RTDs, and PyrometersTempsens Instruments
Various types of Tempsens make temperature Calibration Equipment for calibration of temperature sensors accurately. Temperature sources and master sensors
Black body sources, Reference junction units, Dry block Calibrators, Stirred Liquid Baths, Cold Junction Compensation, AUTOCAL,
The webinar addresses all operators of a vario MAX N/CN cube. We pay attention to frequently asked questions regarding maintenance, method optimization and instrument parameters. Furthermore, we talk about typical sample matrices that can cause problems during the analysis and assist you to solve them.
Practical Analytical Instrumentation in On-line ApplicationsLiving Online
At the end of this workshop participants will be able to:
Recognise and efficiently troubleshoot a wide variety of industrial analytical measuring instruments
Describe the construction and operation of the most important analytical instruments
Define and explain relevant chemical terminology
Identify sample chemical formulae and symbols
Implement procedures for testing and calibration of analytical instruments
WHO SHOULD ATTEND?
Technicians
Senior operators
Instrumentation and control engineers
Electrical engineers
Project engineers
Design engineers
Process control engineers
Instrumentation sales engineers
Consulting ingenious
Electricians
Maintenance engineers
Systems engineers
MORE INFORMATION: http://www.idc-online.com/content/practical-analytical-instrumentation-line-applications-3
Elementar developed a CS analyzer which combines highly accurate data with easy to use, clean and automated processes. Experience the new level of carbon and sulfur determination in metals and inorganic materials. The new inductar CS cube is full of innovative and advanced ideas to make CS analysis more easy to use and more reliable.
MRU AMPRO 2000 GOLD is a powerful handheld gas analyzer suitable for monitoring combustion and industrial processes measure up to 7 gas components. Request FREE Quote Today.
MRU SWG 100 Fixed Biogas Analyzer is the rugged industrial analyzer to use with biogas & biomethane plants, landfill, water treatment as well as coal seam gas sites. Request a FREE quote today.
The Oxymitter™ 4000 In Situ Oxygen Transmitter is the world's first in situ, zirconium oxide-based oxygen transmitter for flue gas measurement with an explosion-proof rating. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency.
Gas detection has been a rising topic in the HVAC industry. As a new topic of discussion, people want to know more in order to better understand the monitoring and detection of many harmful gases. In ACI’s next installment of the 2017 Webinar Series, we break down the key elements that should be used when selecting the proper products and locations of the sensors and controllers when used in your application. Questions? Email ACI: marketing@workaci.com
Handling Difficult Samples in Karl Fischer AnalysisMetrohm USA
Analysis of moisture is becoming increasingly important to many different industries
Many of these reasons require not only a precise, but also accurate reading
For years, most moisture analyses have been conducted on a semi-quantitative or even qualitative level
ENVEA designs and produces a complete range of state of the art CEMS gas and dust analyzers, sampling systems, data acquisition systems and software for the continuous measurement & reporting of stack pollutants.
With the global focus on emissions, the Group helps its clients quickly achieve environmental compliance in the most cost-effective manner.
Industrial emissions monitoring regulations vary from country to country, and the measurement technology must be assessed for suitability and in accordance with local requirements and standards.
Our solutions are fully compliant with the latest European and International regulations & standards.
Diamond Systems Landtec GEM5000 Complete PackageMadison Miller
The GEMTM5000 is designed specifically for use on landfills to monitor Landfill Gas (LFG) Collection & Control Systems. The GEMTM5000 samples and analyzes the methane, carbon dioxide and oxygen content of landfill gas with options for additional analysis.
Pneumatic Products BAP desiccant dryer purifiers are designed to provide a continuous supply of clean, safe breathing air from your existing compressed air system.
Learn about a1-cbiss' refrigeration solutions that cover everything from refrigerant leak detection and monitoring through to emissions control in this brochure
Ideal for oil exploration and extraction the MSA Ultrasonic Gas Detector offers a wide range of detection information. Find out more in this datasheet prepared by gas detection specialists a1-cbiss.
1. Horiba PG-250
Portable Multi-Gas Analyser
The Horiba PG-250 is a highly reliable and
versatile gas analyser for compliance testing of
NOx, SO2, CO, CO2, and O2.
MCERTS approved portable stack testing
Unlike other portable gas analysers that rely upon electrochemical
KEYBENEFITS
•
sensors, the Horiba PG-250 utilises the same measurement principles as a
Compact and lightweight housing
with a built in carrying case so it is
permanently installed CEMS. The PG-250 is ideal for CEMS certification
testing or for use when stack gas emissions must be monitored
periodically at one or multiple stacks.
ideal for moving between stacks
•
Large, easy to read front panel
Direct readings on-site
displays
•
The instrument can interface directly with a laptop computer through
A single portable analyser capable
of measuring five components
an RS-232C interface to record measured values.
Sample conditioning
The Horiba features a built-in sample conditioning system with
sample pump,filters, and a thermoelectric cooler. An optional auxiliary
thermoelectric pre-cooler (PS-200) is available to condition samples
GASESANALYSED
SO2
CO
CO2
O2
“
The ultimate portable MCERTS
analyser that can monitor up to 5
separate components
“
NOx
which contain excess water vapour
2. TECHNICALSPECIFICATION
COMPONENTS MEASURED
• Nitric Oxide (NOx), Sulphur Dioxide (SO2), Carbon Dioxide
(CO2), Carbon Monoxide (CO), and Oxygen (O2)
MEASUREMENT PRINCIPLE
• NOx: Chemiluminescence measurement
• SO2, CO2 & O2: Non-Dispersive Infra Red Absorption
• O2: Galvanic cell measurement
REPEATABILITY, LINEARITY & DRIFT
• Repeatability: ±0.5% F.S. (Nox:>100 ppm; CO:>1000 ppm
±1.0 F.S. (other components and ranges)
• Linearity: ±2.0% F.S.
• Drift: ±1.0% F.S. per day
±2.0% F.S. per day for SO2
DIMENSIONS
• Dimensions: 260 x 260 x 510 mm
PERFORMANCE
• Response time: 45 seconds (moving average from inlet is 10 sec)
• SO2 Response time: Only SO2: 240 seconds with selective
moving average of 10 sec or 30 sec.
• Display: Measured value (3 or 4 digits) active, range, flow
• Sample Gas Flow Rate: Approximately 0.4 SLPM
• Ambien Humidity: <85% R.H
MEASUREMENT RANGES
• NO: 0-25/50/100/250/500/1000/2500ppm
• SO2: 0-200/500/1000/3000 ppm
• CO: 0-200/500/1000/2000/5000ppm
• CO2: 0-5/10/20 vol%
• O2: 0-5/10/25 vol%
POWER
• Power Requirements: 100-120V ac; 200-240V ac at 50/60
Hz
• Power Consumption: 250 VA/400 VA
10.2 x 10.2” x 20.0””
• Weight: 17Kg (37.5Lbs)
BUHLERCOOLER
The cooling block accommodates either a single stream or a
PRODUCT OVERVIEW
separate sample gas streams
Accurate measurements of gases require gas
samples with stable dew points even under
harsh ambient conditions
The Buhler Cooler is available for hire through a1-cbiss, it is
typically used in application with Horiba PG-250. The EGK
models from Buhler provide a compressor-type cooling
system connected to a cooling block. The temperature of
the cooling block is regulated by the Buhler Constant
dual stream heat exchanger hence the cooler may serve two
TECHNICAL SPECIFICATION
• Cooling Capacity: 320kj/h
• Ambient Temperature: +5...+50 oC
• Dewpoint: approx. 5 oC
• Power Consumption: 290/260 VA Fuse (external) 10 A
• Alarm output: max. 250V, 2 A, 50 VA plug acc. to DIN
43650
• Protection Class: IP 20
Regulating System.
11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com
Cert No. 996
ISO 9001