Van Masterson – Summer 2016
Dale Hollow Lake
Celina, TN
July 30, 2016
K-C Internal Use Only
• About Me
• DCS Point Cleanup
• Broke Room HMI
• Dilution Blocking Valve
• Broke Room HMI IP Display Board
• SLC 500 Interfacing
• Other Tasks
• Where To Next
Johnston Space Center
Houston, TX
August 6, 2016
K-C Internal Use Only
• Hometown: Evansville, IN
• School: Senior at Purdue University
• Graduating in December 2016
• Major: Electrical Engineering Technology
• 4th term with K-C
• Mentor: Mike Labhart
• Previous Terms
• 1st & 2nd terms at Berkeley Mills in
Hendersonville, NC
• 3rd term at Loudon, TN
K-C Internal Use Only
• Investigated DCS points using various tools such as
Integrity and point detailing
• Identified 55 definite bad DCS points that can be
deleted
• This doesn’t count the fifteen bad points that
are being repurposed (Cationic Promoter) and
bad points that are part of the TM2 TAD system
• Bad systems that were identified
• OBA Pumps (2102)
• Yellow Dye Pumps (6139)
• Black Dye Pumps (6140)
• RB Pumps (6142)
• Deflaker Discharge to Broke(1363)
• Resolver
• Cationic Promotor(being re-purposed for
DETAC)
K-C Internal Use Only
• Created a CBT on how to investigate potentially bad
DCS points
• The CBT can be used to teach technicians how to
navigate through the DCS
• Deleting unused or obsolete points frees up memory
for future installations and helps to prepare for the
controls upgrade in 2018
• Next Step: Technicians can be trained using the CBT
and the DCS will continue to be cleaned up.
K-C Internal Use Only
• Purpose is to prevent water from leaking through the
existing valve and into the pulper. This makes it more
difficult to control consistency
• Marked up electrical drawings for the installation
• Received quotes from Norman King and ESB for electrical
and mechanical install
• Norman King just needs to wire two inputs
• ESB needs to run air from the solenoid to the valve
• Determined the location of I/O for the ball valve
• Output (Solenoid) – D25, R2, S09
• Inputs (two proximity sensors located on the
valve) – D25, R2, S01
Next Step: The valve will be installed during the next
down on TM2
42RK12
42A Drop 25
TM2 Reel
K-C Internal Use Only
K-C Internal Use Only
• Originally, the goal was to fix the animation
problems with the Kentucky Wildcat graphic
meant to show when Broke was exceeding
expectations
• Once the animation problem was fixed, other
graphics were added to show when Broke was
meeting the target and when they were missing
the target.
• Additionally, the placement of three of the valve
and flow meter pairs was altered to more
accurately reflect where they are in the field.
Essentially, they were shown backwards in the
HMI screen originally
K-C Internal Use Only
K-C Internal Use Only
This appears when Broke is exceeding expectations
>110 BDMTPD
BONE DRY METRIC TONNES PER DAY
K-C Internal Use Only
This appears when Broke is meeting the target production
value
94 < X < 110 BDMTPD
K-C Internal Use Only
This appears when Broke is missing the target
<94 BDMTPD
K-C Internal Use Only
IN MEMORIAM
June 2016 – August 2016
Laettner Graphic
K-C Internal Use Only
• The goal was to figure out how to set up the board
to display messages and display live values from
PLC42A
• Older versions of this board are installed on
converting machines HRT, MBFF, and MFT1
• Has never been used to communicate with a
Modicon PLC
• Currently have an active PLC connection over
Modbus/TCP
• Able to display messages in a particular order
• Next Step: Need to troubleshoot problems with
receiving correct live values from PLC42A
K-C Internal Use Only
• Goal was to figure out how to communicate with the Strapper
#1 SLC PLC and extract the .acd file in case the PLC failed.
• Determined that the 1747-PIC cables that were originally used
to program the SLC’s were obsolete
• PIC’s only work with operating systems older than
Windows XP SP2
• XP mode seems to be XP SP3
• After speaking with Rockwell Automation tech support, it was
determined that a new cable needed to be ordered.
• 1747-UICC13
• Driver can be configured in Windows 7 in RSLinx
STRAPPER #1
SLC 500
• Next Step: The new cable will be ordered and tested on arrival
K-C Internal Use Only
K-C Internal Use Only
• South Package Plant ECO document
• Assisted with troubleshooting problems with the level sensor above the CVA Pulper
K-C Internal Use Only
• Accepted full-time offer to work for K-C in Neenah starting
in January
• Research and Engineering
• West Office Facility 2
K-C Internal Use Only
QUESTIONS??

More Related Content

What's hot

Iii eee-ee8691-embedded sys data communication
Iii eee-ee8691-embedded sys data communicationIii eee-ee8691-embedded sys data communication
Iii eee-ee8691-embedded sys data communication
BalajiK94
 
CRC and Transmitt Error Report_V1
CRC and Transmitt Error Report_V1CRC and Transmitt Error Report_V1
CRC and Transmitt Error Report_V1
Alex TX
 
PROJECT ON WATER CONTROL IN AMUSEMENT PARK USING
PROJECT ON WATER CONTROL IN AMUSEMENT PARK USINGPROJECT ON WATER CONTROL IN AMUSEMENT PARK USING
PROJECT ON WATER CONTROL IN AMUSEMENT PARK USING
Prashant Shekhar
 
Robert Williams Work Experience
Robert Williams Work ExperienceRobert Williams Work Experience
Robert Williams Work Experience
Robert Williams
 

What's hot (20)

PLCopen IEC 61131 Basics 2015 PDF
PLCopen IEC 61131 Basics 2015 PDFPLCopen IEC 61131 Basics 2015 PDF
PLCopen IEC 61131 Basics 2015 PDF
 
15 can.ppt
15 can.ppt15 can.ppt
15 can.ppt
 
Iii eee-ee8691-embedded sys data communication
Iii eee-ee8691-embedded sys data communicationIii eee-ee8691-embedded sys data communication
Iii eee-ee8691-embedded sys data communication
 
Difference between PCI PCI-X PCIe
Difference between PCI PCI-X PCIeDifference between PCI PCI-X PCIe
Difference between PCI PCI-X PCIe
 
CRC and Transmitt Error Report_V1
CRC and Transmitt Error Report_V1CRC and Transmitt Error Report_V1
CRC and Transmitt Error Report_V1
 
PLC Programming Languages
PLC Programming LanguagesPLC Programming Languages
PLC Programming Languages
 
LANswitch Plus Overview Presentation
LANswitch Plus Overview PresentationLANswitch Plus Overview Presentation
LANswitch Plus Overview Presentation
 
CRC AND TRANSMIT ERROR REPORT
CRC AND TRANSMIT ERROR REPORTCRC AND TRANSMIT ERROR REPORT
CRC AND TRANSMIT ERROR REPORT
 
opendayight loadBalancer
opendayight loadBalancer opendayight loadBalancer
opendayight loadBalancer
 
I2C introduction
I2C introductionI2C introduction
I2C introduction
 
OSPF redistribution (open shortest path first)
OSPF redistribution (open shortest path first)OSPF redistribution (open shortest path first)
OSPF redistribution (open shortest path first)
 
3 gpp lte-rlc (1)
3 gpp lte-rlc (1)3 gpp lte-rlc (1)
3 gpp lte-rlc (1)
 
Energy-efficient Path Allocation Heuristic for Service Function Chaining
Energy-efficient Path Allocation Heuristic for Service Function ChainingEnergy-efficient Path Allocation Heuristic for Service Function Chaining
Energy-efficient Path Allocation Heuristic for Service Function Chaining
 
SPI introduction(Serial Peripheral Interface)
SPI introduction(Serial Peripheral Interface)SPI introduction(Serial Peripheral Interface)
SPI introduction(Serial Peripheral Interface)
 
14 superscalar
14 superscalar14 superscalar
14 superscalar
 
Data link control protocol(4)
Data link control protocol(4)Data link control protocol(4)
Data link control protocol(4)
 
CSLA and WTM using GDI Technique
CSLA and WTM using GDI TechniqueCSLA and WTM using GDI Technique
CSLA and WTM using GDI Technique
 
IEC 61131-3 PLC Programming Languages: Beyond Ladder Logic
IEC 61131-3 PLC Programming Languages:  Beyond Ladder LogicIEC 61131-3 PLC Programming Languages:  Beyond Ladder Logic
IEC 61131-3 PLC Programming Languages: Beyond Ladder Logic
 
PROJECT ON WATER CONTROL IN AMUSEMENT PARK USING
PROJECT ON WATER CONTROL IN AMUSEMENT PARK USINGPROJECT ON WATER CONTROL IN AMUSEMENT PARK USING
PROJECT ON WATER CONTROL IN AMUSEMENT PARK USING
 
Robert Williams Work Experience
Robert Williams Work ExperienceRobert Williams Work Experience
Robert Williams Work Experience
 

Similar to Owensboro Final Presentation

IBL Presentation rev FINAL
IBL Presentation rev FINALIBL Presentation rev FINAL
IBL Presentation rev FINAL
Dion Botha
 
AS-BUILT CHECKINGREPORT
AS-BUILT CHECKINGREPORT AS-BUILT CHECKINGREPORT
AS-BUILT CHECKINGREPORT
Mesut Korkmaz
 

Similar to Owensboro Final Presentation (20)

NXP Debug I2C 2022_08_07.pdf
NXP Debug I2C 2022_08_07.pdfNXP Debug I2C 2022_08_07.pdf
NXP Debug I2C 2022_08_07.pdf
 
Loudon Presentation
Loudon PresentationLoudon Presentation
Loudon Presentation
 
IBL Presentation rev FINAL
IBL Presentation rev FINALIBL Presentation rev FINAL
IBL Presentation rev FINAL
 
sairam_CV
sairam_CVsairam_CV
sairam_CV
 
DMX-512A FOR LED CONTROL: Getting Reacquainted With an Old/New Friend by Shos...
DMX-512A FOR LED CONTROL: Getting Reacquainted With an Old/New Friend by Shos...DMX-512A FOR LED CONTROL: Getting Reacquainted With an Old/New Friend by Shos...
DMX-512A FOR LED CONTROL: Getting Reacquainted With an Old/New Friend by Shos...
 
Stanford summer project
Stanford summer project Stanford summer project
Stanford summer project
 
AS-BUILT CHECKINGREPORT
AS-BUILT CHECKINGREPORT AS-BUILT CHECKINGREPORT
AS-BUILT CHECKINGREPORT
 
What Constittutes a Cuality Commissioning job
What Constittutes a Cuality Commissioning jobWhat Constittutes a Cuality Commissioning job
What Constittutes a Cuality Commissioning job
 
Blinking Of LEDs On LPC2148 ARM 7 TDMIS Based Microcontroller
Blinking Of LEDs On LPC2148 ARM 7 TDMIS Based MicrocontrollerBlinking Of LEDs On LPC2148 ARM 7 TDMIS Based Microcontroller
Blinking Of LEDs On LPC2148 ARM 7 TDMIS Based Microcontroller
 
Pulse webinar, 5 HVAC Energy Wasters
Pulse webinar, 5 HVAC Energy WastersPulse webinar, 5 HVAC Energy Wasters
Pulse webinar, 5 HVAC Energy Wasters
 
UFM Downtown San Francisco – Managing Underground Electric Assets in Densely ...
UFM Downtown San Francisco – Managing Underground Electric Assets in Densely ...UFM Downtown San Francisco – Managing Underground Electric Assets in Densely ...
UFM Downtown San Francisco – Managing Underground Electric Assets in Densely ...
 
Lcd
LcdLcd
Lcd
 
Instrumentation Design & Detailed Engineering
Instrumentation Design & Detailed EngineeringInstrumentation Design & Detailed Engineering
Instrumentation Design & Detailed Engineering
 
I2C
I2CI2C
I2C
 
Final Presentation
Final PresentationFinal Presentation
Final Presentation
 
Lect14
Lect14Lect14
Lect14
 
Arithmatic pipline
Arithmatic piplineArithmatic pipline
Arithmatic pipline
 
Zero downtime upgrate for dcs migration Thermo Systems
Zero downtime upgrate for dcs migration Thermo SystemsZero downtime upgrate for dcs migration Thermo Systems
Zero downtime upgrate for dcs migration Thermo Systems
 
DCS migration - zero downtime upgrade
DCS migration - zero downtime upgradeDCS migration - zero downtime upgrade
DCS migration - zero downtime upgrade
 
1.LIFT operations.ppt
1.LIFT  operations.ppt1.LIFT  operations.ppt
1.LIFT operations.ppt
 

Owensboro Final Presentation

  • 1. Van Masterson – Summer 2016 Dale Hollow Lake Celina, TN July 30, 2016
  • 2. K-C Internal Use Only • About Me • DCS Point Cleanup • Broke Room HMI • Dilution Blocking Valve • Broke Room HMI IP Display Board • SLC 500 Interfacing • Other Tasks • Where To Next Johnston Space Center Houston, TX August 6, 2016
  • 3. K-C Internal Use Only • Hometown: Evansville, IN • School: Senior at Purdue University • Graduating in December 2016 • Major: Electrical Engineering Technology • 4th term with K-C • Mentor: Mike Labhart • Previous Terms • 1st & 2nd terms at Berkeley Mills in Hendersonville, NC • 3rd term at Loudon, TN
  • 4. K-C Internal Use Only • Investigated DCS points using various tools such as Integrity and point detailing • Identified 55 definite bad DCS points that can be deleted • This doesn’t count the fifteen bad points that are being repurposed (Cationic Promoter) and bad points that are part of the TM2 TAD system • Bad systems that were identified • OBA Pumps (2102) • Yellow Dye Pumps (6139) • Black Dye Pumps (6140) • RB Pumps (6142) • Deflaker Discharge to Broke(1363) • Resolver • Cationic Promotor(being re-purposed for DETAC)
  • 5. K-C Internal Use Only • Created a CBT on how to investigate potentially bad DCS points • The CBT can be used to teach technicians how to navigate through the DCS • Deleting unused or obsolete points frees up memory for future installations and helps to prepare for the controls upgrade in 2018 • Next Step: Technicians can be trained using the CBT and the DCS will continue to be cleaned up.
  • 6. K-C Internal Use Only • Purpose is to prevent water from leaking through the existing valve and into the pulper. This makes it more difficult to control consistency • Marked up electrical drawings for the installation • Received quotes from Norman King and ESB for electrical and mechanical install • Norman King just needs to wire two inputs • ESB needs to run air from the solenoid to the valve • Determined the location of I/O for the ball valve • Output (Solenoid) – D25, R2, S09 • Inputs (two proximity sensors located on the valve) – D25, R2, S01 Next Step: The valve will be installed during the next down on TM2 42RK12 42A Drop 25 TM2 Reel
  • 8. K-C Internal Use Only • Originally, the goal was to fix the animation problems with the Kentucky Wildcat graphic meant to show when Broke was exceeding expectations • Once the animation problem was fixed, other graphics were added to show when Broke was meeting the target and when they were missing the target. • Additionally, the placement of three of the valve and flow meter pairs was altered to more accurately reflect where they are in the field. Essentially, they were shown backwards in the HMI screen originally
  • 10. K-C Internal Use Only This appears when Broke is exceeding expectations >110 BDMTPD BONE DRY METRIC TONNES PER DAY
  • 11. K-C Internal Use Only This appears when Broke is meeting the target production value 94 < X < 110 BDMTPD
  • 12. K-C Internal Use Only This appears when Broke is missing the target <94 BDMTPD
  • 13. K-C Internal Use Only IN MEMORIAM June 2016 – August 2016 Laettner Graphic
  • 14. K-C Internal Use Only • The goal was to figure out how to set up the board to display messages and display live values from PLC42A • Older versions of this board are installed on converting machines HRT, MBFF, and MFT1 • Has never been used to communicate with a Modicon PLC • Currently have an active PLC connection over Modbus/TCP • Able to display messages in a particular order • Next Step: Need to troubleshoot problems with receiving correct live values from PLC42A
  • 15. K-C Internal Use Only • Goal was to figure out how to communicate with the Strapper #1 SLC PLC and extract the .acd file in case the PLC failed. • Determined that the 1747-PIC cables that were originally used to program the SLC’s were obsolete • PIC’s only work with operating systems older than Windows XP SP2 • XP mode seems to be XP SP3 • After speaking with Rockwell Automation tech support, it was determined that a new cable needed to be ordered. • 1747-UICC13 • Driver can be configured in Windows 7 in RSLinx STRAPPER #1 SLC 500 • Next Step: The new cable will be ordered and tested on arrival
  • 17. K-C Internal Use Only • South Package Plant ECO document • Assisted with troubleshooting problems with the level sensor above the CVA Pulper
  • 18. K-C Internal Use Only • Accepted full-time offer to work for K-C in Neenah starting in January • Research and Engineering • West Office Facility 2
  • 19. K-C Internal Use Only QUESTIONS??