4. 03|electricalsupplysystem
Reflected Ceiling Plan: First floor
Scale 1:150
Lighting Switches & Sockets Mechanical Ventilation
Electrical
Electronics
Recessed ceiling light
Emergency light
Wall light
Outdoor light
Flourescent light
One gang switch
Two gang switch
Three gang switch
Two way switch
Air cond switch
Heater switch
Telephone socketTelephone socket
One gang socket
Multiple gang socket
Air conditioner
Air−cond compressor
Ceiling fan
Exhaust fan
Television
Telephone
CCTV
Doorbell
Distribution board
Electrical meter
LEGEND
SYSTEM
5. ELECTRICAL SUPPLY SYSTEM
Electrical
Distribution Board Electric Meter
Socket
One−gang Twin−gang Telephone
Brand:
Schneider Electric
Dimension:
87 x 87mm
Rated Operational
Voltage:
250V250V
Brand:
Schneider Electric
Dimension:
148 x 87mm
Rated Operational
Voltage:
250V250V
Brand:
Schneider Electric
Model:
Pieno
Dimension: 87 x 87mm
Brand:
Schneider Electric
Model:
3 Phase Distribution
Board, 250 A
Mk10D Smart Three
Phase
Electronic Revenue
Meter with Disconnect
and Reconnect Feature
Atlas series
Class 1
04|electricalsupplysystem
6. ELECTRICAL SUPPLY SYSTEM
05|electricalsupplysystem
Switch
One−gang Two way one−gang
Brand:
Schneider Electric
Switch function:
One way
Dimension:
87 x 87mm
Rated OperationalRated Operational
Voltage:
250V
Brand:
Schneider Electric
Switch function:
Two way
Dimension:
87 x 87mm
Rated OperationalRated Operational
Voltage:
250V
Three gang Heater Switch Air−con Switch
Brand:
Schneider Electric
Dimension:
86 x 86mm
Rated Operational
Voltage:
250V250V
Brand:
Schneider Electric
Dimension:
87 x 87mm
Rated Operational
Voltage:
250V250V
Brand:
Mind
Dimension:
86 x 86mm
Rated Operational
Two−gang
Brand:
Schneider Electric
Dimension:
86 x 86mm
Rated Operational
Voltage:
250V250V
7. ELECTRICAL SUPPLY SYSTEM
06|electricalsupplysystem
Outdoor
Door Bell
Outdoor wall lamp
Brand:
OD Lighting
Dimension:
311mm height
Rated Operational
Voltage:
220V220V
Bulb: E27
Autogate
Brand:
Schneider Electric
Model:
Kavacha
Brand:
DELUX
System:
Trackless folding gate
Outdoor lamp
Brand:
OD Lighting
Dimension:
800mm height
Rated Operational
Voltage:
220V220V
Bulb: E27
8. ELECTRICAL SUPPLY SYSTEM
07|electricalsupplysystem
Ventilation
Air−conditioning Air Conditioner
Compressor
Brand: Panasonic
Model: CS−S10PKH
Dimension:
870x290mm
Depth: 214mm
Running Current: 3.6A
Brand: Panasonic
Model: Standard Series
Wall Mounted Heat
Pump
Exhaust Fan Ceiling Fan
KDK Remote Control
Type
Fan Diameter:
1400mm
Height: 496.8mm
Motor W: Low 33.5
High 65
KDK Wall Mount
Propeller
Dimension:
300 x 310mm
Motor Rating:
240V / 50Hz
9. ELECTRICAL SUPPLY SYSTEM
08|electricalsupplysystem
Indoor
lighting
Recessed downlight Fluorescent Light
Wall light Emergency light
Brand:
Ikea, NYMÅNE
Dimension:
15cm height, 7cm ø
Bulb:
LED bulb GU10 400LED bulb GU10 400
lumen
Brand:
PNE
Dimension:
410mm x 165mm x 100
mm
Back up duration:
3 hours3 hours
Brand: Yetplus
Material: Die cast
Dimension:
160mm ø
Wattage: 12W
Brand: Philips
Model: TL5
Dimension: 1162mm
Fitting/Cap: G5
Wattage: 28W
12. HOT AND COLD WATER SUPPLY SYSTEM
11|coldandhotwatersupplysystem
Valves
Gate Valve Water meter Stop cock
Volumetric Rotary
Piston Water Meter
Water temperature : ≤
50 oC
Working pressure : ≤
1.6 MPa
Material: Brass
Dimension: 30 x 95 x
63mm
Size: 1/2" − 1"
Material:Brass
Pressure Range:
1.6mpa
Pipes
Copper Pipe UPVC Pipe Stainless Steel Pipe
Hot water
Diameter: 12mm
Cold water
Class D uPVC pipe
Diameter: 25mm, 40mm
Incoming pipe
32mm
13. 12|coldandhotwatersupplysystem
TankBoiler
Water tankWater Heater
Brand: Kossan
Effective Capacity: 250G
Nominal Capacity: 300G
Size:
1500 x 889 x 1040mm
Brand: Alpha
Centralized Multipoint
System
Electrical Rating:
3.30kW 240 V
Water TemperatureWater Temperature
Control: 70°C
HOT AND COLD WATER SUPPLY SYSTEM
Ground floor plan
Living room
Dining roomToilet
17. 16|sewerage&sanitarysystem
SANITARY PLUMBING LAYOUT, SEWERAGE
LAYOUT, SURFACE WATER DRAINAGE:
Ground floor plan
Scale 1:150
LEGEND
Man hole
Drain sump
Floor trap
Gully trap
Rainwater downpipe
Embedded perimeter drainage
Flow of service
SEWERAGE&SANITARY
03
18. SEWERAGE AND SANITARY SYSTEM
17|sewerageandsanitarysystem
Traps & Sump
Manhole Floor trap
Class C250
Dimensions:
600 x 600mm
Material:
Stainless steel
Model No.: SFT−804
Dimension: 80 x 80mm
Bottle trap Drain Sump
Material: High Density
Polyethylene
Dimension:
350 x 350mm
Material: uPVC
Diameter: 40mm
Gully trap
Material: High Density
Polyethylene
Dimension:
200 x 200mm
19. SEWERAGE AND SANITARY SYSTEM
18|sawerageandsanitarysystem
Pipes Ventilation
UPVC Pipe Vent Cowl
Class D uPVC pipe
Diameter:
40mm, 76mm, 100mm
Polypipe Vent Cowl
Terminal
Diameter: 110m
VCP Pipe
Diameter: 100mm
Material: Ceramic
23. TABLE OF
CONTENTSREFERENCES
Ching, Frank and Cassandra, A(2001). Building Con−
struction Illustrated. New York. Wiley. Print.
Stein, Benjamin and Reynolds, Join S, 2000. Mechani−
cal and Electrical Equipment for Buildings. New York.
John Wiley.
Chudley, Roy, 1988, Building Finishes, Fittings and
Domestic Services, 2nd Edition, Longman.
Greeno, R, 2000, Building Services Equipment, 5th
edition, Longman.
Uniform Building By−Laws 1984: all amendments up to
September 1995: Act 133. (1995). Kuala Lumpur;
MCD.
Kossan PE Water Tank Malaysia. Retrieved fromKossan PE Water Tank Malaysia. Retrieved from
https://www.ewarehouse.atkc.com.my/Kossan−N250−
SA−PE−Wa−
ter−Tank−Square−Series−1500MM−T−x−1170MM−B−300G
−NC
ALP−50L−H/V STORAGE WATER HEATER ALPHA
Johor Bahru JB Malaysia Supply & Install | Super Fast
Air Cond & Electrical Sdn. Bhd. Retrieved from
https://m.superfast.com.my/index.php?ws=showprod−
ucts&prod−
ucts_id=1998044&cat=ALPHA&subcat=STORAGE−WA
TER−HEATER
Designer & Luxury Showering – KOHLER. Retrieved
from https://www.kohler.my/browse/bathroom/Catego−
ries/bath−
room−showering/ProductType/Shower+Columns+and+
Panels
ELVERDAM Kitchen faucet, s. ELVERDAM Kitchen
faucet − IKEA. Retrieved from https://ww−
w.ikea.com/us/en/catalog/products/40211576/
22|references