1. CURRICULUM VITAE
JAGJEEVAN WARIYA (jrwariya@rediffmail.com)
Certified Painting Inspector –NACE Level -2
OBJECCTIVE
+09 year of work experience as QC Inspector in the field & shop Painting /Coating at petrochemical
Industries, Desalination /power plant and waste water treatment plants. To work with a progressive
organization where my potential skills can be utilized for improving the quality, performance and in
contributing substantially towards the growth of the organization. Exposures are included with Oil &
Gas processing plant & Petrochemical cross country pipelines Executed prestigious projects with
expertise in multidimensional execution of projects for multiple clients along with optimizing resource
utilization and contract management. Proficient with present construction methodologies, System in
compliance with quality standards. Exemplary relationship, management, communication skills with
the ability to network with project member, Consultant’s contractors and statutory agencies with the
consummate ease.
EDUCATIONAL QUALIFICATION
Diploma in Electrical Engineering (1997)
PROFESSIONAL
Certified Painting Inspector NACE CIP LEVEL -2 Certificates No: 23356 (Year-2013)
Certified Painting Inspector NACE CIP LEVEL -1 Certificate No: 23356 (Year-2009)
PROFESSINAL EXPERIENCE
Company : Technimont ICB Pvt. Ltd.
Period : April - 2014 to June – 2014.
Designation : Sr. Execution Painting Engg.
Project : Dahej Petrochemical complex
Client : ONGC PETRO additions Ltd. (OPaL) Dahej , Gujarat.
Work Executed : Painting Inspection of Structure and Piping, Oil Storage Tank. Hot and Cold
Insulation Inspection of Piping. Wrapping Coating Inspection of Underground
Piping.
2. Company : ABS IV (American Bureau Of Shipping Industrial Verification)
Period : June-2013 to March-2014.
Designation : Painting Inspector
Project : Bhogat Storage Tank Project Jamnagar, Gujarat.
Client : CARIN INDIA PTY LTD.
Work Executed : Painting Inspection of Structure and Tank, Piping, wrapping Coating Inspection
of Underground Piping.
Company : Corrosion Technology Services (CTS )
Period : April-2013 to May-2013.
Designation : Coating Inspector/ Surveyor
Project : RAS Gas Monitoring and Maintenance Project (Shutdown).
Client : RAS GAS, Doha- Qatar.
Work Executed : For Coating Maintenance, Blasting and Painting Inspection of Utility Water
Tanks.
Company : ABS IV (American Bureau Of Shipping Industrial Verification)
Period : June-2012 to Sept-2012.
Designation : Painting Inspector
Project : Industrial Painting Work At KONABAN, ROKHIYA, ADB & BRM GCS On Supply
And Apply Basis through Paint Manufacturer’’ Of Tripura Asset. Unit: ADB
GCS & BRM GCS.
Owner : ONGC, Agartala, Tripura, India.
Work Executed : For painting maintenance Inspection of structure and piping , Oil storage tank
Including all related documentation activities.
Company : ABS IV(American Bureau Of Shipping Industrial Verification)
Period : Apr-2011 to Apr-2012.
Designation : Painting Inspector/ Coating Inspector
Project : Bhogat CO storage Tank Terminal (MDPP) Project Jamnagar, Gujarat.
Owner : CARIN INDIA PTY LTD.
Work Executed : Painting Inspection of Structure and Piping, Oil Storage Tank.
Hot and Cold Insulation Inspection of Storage Tank, Piping. Wrapping Coating
Inspection of Underground Piping.
3. Company : Quilon Real Engineering & Construction Pvt. Ltd.
Period : Jan-2010 to Apr-2011.
Designation : Coating Inspector/Painting Inspector
Project : ONGC (OPaL) project, Dahej, Gujarat.
Owner : ONGC/Samsung Engineering
Period : Jan-2007 to Dec -2009.
Company Name : Nicco Corporation Ltd. & Pekon India
Project : Kamalapuram to Kutthalam Oil Distribution Project (Vap) (3” Pipeline 64km)
Client : Oil & Natural Gas Corporation Ltd. (ONGC)
Position : Third Party Inspector (Coating)
Knowledge in various Paintings Systems during the Projects:
Epoxy Coating System at Atmospheric & Immersion Services. High Temp. & Very High Temp. Coating
Systems. Organic & Inorganic Zinc Primer, Solvent & FBE Coating, High build Epoxy , Polyurethane
Coating Systems.
Paint Manufacture: Berger paint, Asian paints, International, OASIS Ameron, Hempel & Sipco. Some
Special paints.
Handled : Belzona 1511 & 1345 coating for internal surface of the pipes lining .High Temp. 1027
Coating for Hot & Cold Insulated substrate of all 300 Series SS Pipe.
JOB RESPONSIBILITIES AS PAINTING INSPECTOR
Documents Review and Compliance
Receipt of Coating Specification and enforce it. Receipt of Inspection and Test Plan (ITP) and adhere to
it. Receipt of the approved QA/QC Procedure and comply to it.
Receipt of the approved QC Report Format and use it for reporting. Review Qualification of personnel
to ensure that the required skill is there.
Review Calibration certificate of QC instruments to ensure that those are from the approved agencies
and are valid.
Review Technical Data Sheets and Material Safety Data Sheets of the approved Paint Materials to
ensure that those are available at site.
Review Technical Data Sheets/Broachers and Test Reports of the approved Blast Abrasive to ensure
that those are available at site.
Receipt and review Batch Certificate of Paint Materials to ensure that the materials have been tested
and inspected in accordance with the applicable standards before dispatching to site and shelf life is
valid.
Blasting Area:
Preparation of substrates before application of paint and related. Products-visual assessment of
surface cleanliness AS PER SSPC VIS & ISO- 8501-1, Surface preparation as per NACE Standard.
Surface preparation as per Solvent Clean as per SSPC-SP-1. Surface preparation as per Manual Hand
Tool Cleaning as per SSPC-SP-2.
4. Surface preparation as per Power Tool cleaning as per SSPC- SP-11.
Follow more Surface Preparation Standards as per required by client.
Final Product:
Final product check as per SSPC PA-2 (TYPE 1&2)
Final product check as per NACE RP 0188, Holiday testing (LV & HV)
Instruments:
Function and calibrations of the following instruments used in Blasting /Painting / Coating inspection.
Environment Test .
Instrument :
Sling-Psychrometer, Digital Hygro-meter and Weather Tables. Surface Temp.
Indicatory :
Magnetic Type, Thermo Couple Temp Type. Contact Infrared Temp. Indicator
Surface Profile & Cleanliness :
Profile Comparators, Press-O-film, Magnifying, Glass (X-10- 30) .
Destructive and Nondestructive:
Salt Contamination by SCM m/c, Titration Method, Dustiness level by Magic Tape. WFT gauge (comb
gauge), DFT gauge Magnetic pull of gauge (Banana Gauge),
Electronic Pressure Gauge) Adhesion Tester (Cross Cut) As per ASMT 3359.
Tester (low voltage, High voltage) Holiday, Took Gauge.
Reports:
Surface preparation such as Method of preparation, Standards, Abrasive used, Cleanness, Roughness
and Climatic conditions.
Coating such as Method of coating, Paint system, Number of coats, Weather condition, Air
temperature, Maximum relative humidity, Steel temperature, Dew point, Paint Specification, Paint
Manufacturer, Batch number, Production date, Expire date/ Shelf life, Required DFT in microns
Measured WFT in microns, Measured DFT in microns. Details of Q/C Instruments used such as
Hygrometer, Steel temperature gauge, Profile gauge, DFT Gauge Holiday detector. Details of
Inspected Item. Condition of Inspected item/Details of repair if any.
Personal Profile
Date of Birth : 3rd April 1973
Permanent Address : Krishna Puram Colony, Indira Nagar, New Yard Itarsi -461115
District- : Hoshangabad Madhya Pradesh
Languages Known : Hindi & English
Passport No. : G7505915
Place: JAGJEEVAN WARIYA
+91-9926320230