1. Rajesh Kannan R
BGAS certified coating inspector –level 2 (cert.No:683254)
Mobile #: +971-55 1929557 / E-mail: rajeshkannan.kkya@gmail.com
PROFILE SNOPSYS:
Bgas certified coating inspector having more than three years’ experience in inspection and supervision of
blasting and painting activities of pre-engineered and structural fabricated members.
EDUCATION AND CERTIFICATIONS:
Diploma in Mechanical engineering from theni kammavar sangam polytechnic college, Theni-
(2010-2013).
B.Tech in Mechanical engineering from Karnataka University, Madurai- (2014-on progress).
Bgas Certified Coating Inspector level 2- cert. no: 683254 (valid up to January 2021).
Certified Inspector British galvanizers association.
American society for non-destructive testing Certified Inspector level 2 (valid up to August 2018)
(UT, MPI, LPT, VT, RT and RTFI).
Other Trainings & Certifications:
• Attended the workshop on Productivity improvement in Blast cleaning by SSPC-UAE chapter.
• Attended the workshop on PFP coating technology & advancement in DFT measurements by SSPC –
UAE.
• Paint school training by Jotun paints –Middle East.
PROFESSIONAL SKILS:
• Quality Assurance / Control.
• Surface defects/Failure analysis and trouble shooting
• Testing and Inspection
• Supervise Blasting/ Surface Preparation and coating activities
• Counselling workers
• Drafting reports
• Making method statement and painting procedures
• Evolution and reviewing specification
• Process improvement and innovation
• Welding and Fit up checking as per dimension and elevation mention in drawing
COMPUTER SKILS:
• MS.Office, Excel, Word and Power point.
1
2. • Auto cad
• Architectural Cad
Familiar Coating Systems:
• Inorganic (Zinc silicate) and organic zinc rich primers
• Epoxy paints including amine ,amide ,phenol alkamine cured and glass flake epoxy coatings
• Hot dip galvanizing
• Duplex Paint systems on HDG surfaces
• Polyurethane and matured polysilioxane top coats
• Alkyd Paint systems
Familiar Surface preparation and Paint application Methods:
• Centrifugal wheel abrasive blast cleaning
• Compressed air blasting
• Hand and Power tool cleaning
• Solvent cleaning and degreasing
• Airless Spray and Air spray application
• Automatic Paint line (booth ) with force curing
• Brush and Roller applications
PROFESSIONAL EXPERIENCE:
MABANI BUILDING SYSTEMS & CONSTRUCTION GROUP – (RAK –UAE)
POSISTION: Quality Inspector (coating)-September 2013 to Till date.
Mabani building system is a one of the leading manufacturer of Pre-engineered Building and structures
in the Middle East.Mabani has achieved ISO 9001 accreditation in Quality Management System and ISO
14001 Environmental Management System.
Major projects handled:
1. Project: Aircraft Maintenance Hangars
Location: Jeddah, Kingdom of Saudi Arabia.
Client: TAL Joint Venture
End user: Saudi Aerospace Engineering Industries
Position: QC –inspector
2. Project: AL Ain International Airport MRO Facility
Location: Al ain, UAE
Client: Al Faraa General Contracting
End user: Government
Position: QC –inspector
3. Project: EPC expansion of storage facilities at BAB-13
Location: BAB-13, 180 Km south west of Abu Dhabi, UAE
2
3. Client: Khansaheb Civil Engineering LLC
End user: ADCO
Position: QC –inspector
4. Project: New aviation fuel depot for Abu Dhabi international airport
Client: Larsen & Toubro Limited
End user: Takreer
Position: QC –inspector
5. Project: EICP OF GAS SWEETENING FACILITIES
Location: Qatar
Client: Petrofac Engineering & Construction
End user: Qatar Petroleum
Position: QC –inspector
6. Project: New Gathering Centre GC31 at North Kuwait
Location: KOC GC31, Kuwait
Client: Dodsal Engineering & Construction
Position: QC –inspector
7. Project: Bader Almulla & Sons Showroom
Location: Kuwait
Client: Asian Group Co. General Trading & Contracting
End user: Bader Almulla & Sons
Position: QC –inspector
8. Project: King Faisal corniche development
Location: Bahrain
Client: ARC Steel construction WLL
Position: QC –inspector
9. Project: Gas Compression & Reinjection Station, ZCINA, North Algeria
Location: Hessi Messoud, North Algeria
Client: Dodsal Engineering and Construction Pvt Ltd
End user: Gas Compression & Reinjection Station, ZCINA, North Algeria
Position: QC –inspector
10. Project: COIL COATING LINE FOR OARC
Location: Sohar, Oman
Client: Habtoor Leighton Group
End user: Oman Aluminium Rolling Company
Position: QC –inspector
Roles & Responsibilities:
• Stage wise Inspection of coating on steel structures
• Verify surface and weld defects to be removed before starts of surface preparations
3
4. • Monitor weather condition for surface preparation and paint application.
• Execute Painting / coating inspection work as per company project inspection test plan.
• Giving adequate training and advises to blasters ,painters ,foreman and supervisor to improve
quality on regular basis
• Monitor performance of the blasters and painters
• Responsible for incoming painting material inspection and has to ensure whether these materials
suits to meets the requirements of project specifications.
• Prepare all necessary QA / QC documents related to painting and handed over to clients review.
• Review of calibration status of all testing and inspection equipments.
• To undertake test qualifications for spray painters and abrasive blasters.
• To co-ordinate and conduct trials for paint systems for prior approvals
• Maintain standards of safety and comply with company safety health and environment
management systems.
• Coordination with client regarding inspection requirements and schedule of inspection
• Ensure dry film thickness as per specifications and standards.
• Conduct adhesion and curing tests.
• Check colour, gloss level and uniformity of the applied paint.
Chennai petroleum corporation Ltd (Chennai, India) From April 2013 to September 2013.
POSISTION: Quality control Inspector
Roles & Responsibilities:
• Responsible for all field inspections and coordination of inspection activities to
ensure the quality level in contract & working as a team member of project
management team.
• Attend pre-inspection meeting with main contractor prior to the start of any work to
clarify requirements, plans and procedures.
• Ensures that the QC/Inspection work proceeds in accordance with project quality
plan, control procedures and inspection procedures agreed with the contractor
Familiar inspection correspondence to international standards:
• Familiar with monitoring environmental parameters using dew check meter and psychometric dew
point meter (ASTM E 337 )
• Evolution of dust level by pressure sensitivity tape method as per ISO-8502-3
• Visual surface roughness by using pre-blasted profile comparator,testex method (ISO-8503-1)
• Visual assessment of rust grades as per ISO 8501-1
• Surface preparation by solvent cleaning ,hand and power tool cleaning (SSPC SP1,SP2,SP3)
• Evolution of blast cleaning with reference to ISO-8501- Sa3,Sa2.5,Sa2 and Sa 1
• Salt test by using bressle patch and SCM 400 –Salt contamination meter as per ISO 8502-6 and ISO-
8502-9
• WFT measurement as per ISO-2808
4
5. • Dry film thickness verification as per SSPC PA2 ,ISO-19840 and ISO-2808
• Adhesion tape test (ASTM D 3359 & ISO-2409 ) X-cut ,Cross cut tests
• Evolution of curing in inorganic coatings MEK resistance test as per ASTM D 4752
• Pull off adhesion test as per ASTM D 4541
• PERSONAL DETAILS:
Sex Male
Father’s Name V. Ramasubbu
Nationality Indian
Marital Status Single
Date of birth 03-03-1991
Passport No K8968994
Languages known
English ,Tamil (read, write and speak),Hindi, Malayalam and Telugu
(To speak).
Permanent address
5/24, Koolipatti, Neeravi (Po), Kamuthi (Tk), Ramanathapuram (Dt)
Tamilnadu, India-623603.
DECLERATION:
I hereby declare that that all the above details are true and correct to the best of my knowledge
and belief. I promise you that I will be a Dynamic Personality who is very truthful and loyal to contribute
to the organization’s goal.
DATE: 02/7/2016 TRUTHFULLY
Ras Al khaimah, UAE RAJESH KANNAN. R
5
6. • Dry film thickness verification as per SSPC PA2 ,ISO-19840 and ISO-2808
• Adhesion tape test (ASTM D 3359 & ISO-2409 ) X-cut ,Cross cut tests
• Evolution of curing in inorganic coatings MEK resistance test as per ASTM D 4752
• Pull off adhesion test as per ASTM D 4541
• PERSONAL DETAILS:
Sex Male
Father’s Name V. Ramasubbu
Nationality Indian
Marital Status Single
Date of birth 03-03-1991
Passport No K8968994
Languages known
English ,Tamil (read, write and speak),Hindi, Malayalam and Telugu
(To speak).
Permanent address
5/24, Koolipatti, Neeravi (Po), Kamuthi (Tk), Ramanathapuram (Dt)
Tamilnadu, India-623603.
DECLERATION:
I hereby declare that that all the above details are true and correct to the best of my knowledge
and belief. I promise you that I will be a Dynamic Personality who is very truthful and loyal to contribute
to the organization’s goal.
DATE: 02/7/2016 TRUTHFULLY
Ras Al khaimah, UAE RAJESH KANNAN. R
5