2. Typical Camera Installation
Analog
Camera
RG59U Coaxial Cable
18/2 Power Cable
Low Voltage
Power Supply
P/T/Z Controller
Analog DVR
MonitorAnalog CCTV Systems Were Installed
With A Collection Of Homerun Cables
With An Average Distance of 575ft.
3. Typical Camera Installation
Analog
Camera
RG59U Coaxial Cable
18/2 Power Cable
Low Voltage
Power Supply
P/T/Z Controller
Analog DVR
Monitor
18/2 Is Connected Between a Power
Supply And The CCTV Camera
4. Typical Camera Installation
Analog
Camera
RG59U Coaxial Cable
18/2 Power Cable
Low Voltage
Power Supply
P/T/Z Controller
Analog DVR
Monitor
A Twisted Pair Cable Was Typically
Installed For P/T/Z Control Signals
5. Typical Camera Installation
Analog
Camera
RG59U Coaxial Cable
18/2 Power Cable
Low Voltage
Power Supply
P/T/Z Controller
Analog DVR
Monitor
RG59U Coaxial Cable Was The
Primary Cable Installed
Between The Camera And DVR
9. Typical Camera Installation
Once The Transmitter Is Powered, It Checks To
Confirm The Camera Or Connected Network
Device Requires PoE and Sends Accordingly.
10. Typical Camera Installation
Once Power Is Established Throughout The
System The Transmitter And Receiver
Communicate To Determine The Cable
Distance And Create An Open Data Channel
11. EL1500C Connections and LED Indicators
BNC Connector -
Attaches to Existing RG59U
Coaxial Cable
BNC Side of Device RJ45 Side of Device
12. EL1500C Connections and LED Indicators
BNC Side of Device RJ45 Side of Device
Link LED Indicator
On Solid = 100Mb
Flashing = 10Mb
Off = No Link
13. EL1500C Connections and LED Indicators
PoE Out LED Indicator -
On = PoE Is Being Sent Over Coax
Off = PoE Is “NOT” Being Sent Over Coax
BNC Side of Device RJ45 Side of Device
14. EL1500C Connections and LED Indicators
RJ45 Connector
Attaches To Network Device
BNC Side of Device RJ45 Side of Device
15. EL1500C Connections and LED Indicators
Link Status LED Indicator
On Solid = Ethernet Link
Off = No Ethernet Link
BNC Side of Device RJ45 Side of Device
16. EL1500C Connections and LED Indicators
Power LED Indicator
• On Solid = The Unit Is Powered And Ready To Use
• Off = The Unit Is Not Receiving Power
BNC Side of Device RJ45 Side of Device
17. EL1500C Connections and LED Indicators
Optional Power Input
Class II 48-56VDC Input To create PoE In
Installations Where a PoE Switch Is Not
Available.
BNC Side of Device RJ45 Side of Device