3. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
Continuous modulation for CO2 systems
Latest innovation to further spread out CO2 technologies
Main targets:
CO2 available in all formats
Energy efficiency improvements (warm climates)
Extremely wide modulation range with DC tech.
Ease of use
Total connectivity
Small-medium formats
New focus of natural efficiency deployment
4. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
HypermarketSupermarketSmall formatsC-Store
Technologies for all formats
Market size versus Application
5. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
Future proof technology
Efficiency in ALL conditions
Increased efficiency at partial load
Wide capacity modulation
Reduced ON/OFF cycles: the refrigeration circuit
needs time to reach the nominal efficiency
A refrigeration application is working for the
largest part of the time at partial load
DC technology Permanent magnets variable speed
compressors driven by intelligent DC
drivers (inverters)
Advanced DC drivers modulation
Focused on compressor protection
& control
Optimized for a wide range of BLDC
compressors
Designed for smart integration in
the unit
Class B software (EN 60730-1):
embedded compressor protection
Unit protection saving additional
components
6. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
0,00
0,40
0,80
1,20
1,60
2,00
0% 20% 40% 60% 80% 100%
COP
Cooling Load
DC*
AC*
1,00
1,50
2,00
2,50
3,00
3,50
4,00
4,50
50,00 60,00 70,00 80,00 90,00 100,00 110,00
COP
HP [bar]
AC*
DC*
Lab test data
DC Vs AC Compressor comparison
*semi-hermetic reciprocating 2 pistons with AC speed drive
Cooling capacity MT (-10 °C, 50 Hz):
- 2,4 kW (100 bar)
- 3,4 kW (66 bar)
* DC Single Rotary Brush Less with DC speed drive
Cooling capacity MT (-10 °C, 60 rps):
- 2,1 kW (100 bar)
- 2,7 kW (66 bar)
Higher efficiency in every load condition
Wider modulation range
Higher maximum speed (up to 100rps)
Lab test data
7. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
DC Transcritical Condensing Units
New frontier in efficiancy
High efficiency DC inverter compressors for CO2
Wide and real capacity modulation
Self-optimization through real time communication
with refrigerated units
Total connectivity
Total connection with Carel supervisory systems and IOT
services
Performance monitoring and full settings management
Periodical reports and stores benchmarking
System benefits
8. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
Increased reliability
Full compressor’s envelope control
No system down-time for oil return issues
Stable product temperature thanks to modulating
devices and floating setpoints
System benefits
DC Transcritical Condensing Units
Ease of use
System solution in compact, fully-integrated equipment
Intuitive programming and fast commissioning tools
Compact dimensions and weight
MT unit
LT unit
9. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
Multi DC Racks
Multiple parallel DC compressors
System benefits
Efficiency without compromise
High energy efficiency with multiple DC
compressors modulation
Extremely wide modulation range 5-100%
Wider system modularity
Overall compactness and silence
Unit compact design
Low weight, easier to carry
Low noise solution
10. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
Perfect for retrofits and shops downtown
Suitable for the installation inside the store
NarRef CO2 application to retrofit outdated HFC store
Complete solution for express stores in the city centre
Multi DC Racks
Multiple parallel DC compressors
System benefits
Ease of use and reliability
Intuitive programming and fast commissioning tools
Specifically designed oil equalisation and distribution features
Enhanced safeties: full envelope control and oil return functions
11. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
Main DC technology applications
Condensing unit Multi DC Racks
12. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
AC driven rack
DC driven rack
External
Temp. [°C]
DC vs AC
saving [%]
20 +13%
21 +14%
22 +15%
23 +13%
24 +14%
25 +15%
26 +16%
27 +15%
28 +12%
29 +12%
30 +14%
31 +10%
Energy consumption observed during 2018
External temperature from 16 to 39°C
Advansors pack real field data
Booster systems with DC compressors Vs standard AC solution
Multi DC Racks
DC Vs AC field data comparison
13. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
Efficiency: continuous modulation to maximize energy efficiency in all climates and in all formats
Performance: optimum control of modulating devices to enhance system stability and food quality
Reliability: reduced compressors cycling and safe envelope management
Cost effectiveness: reducing system and components complexity to decrease return of investments
Availability for small&medium formats
Conclusions
14. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017
15. This document and all of its contents are property of CAREL. All unauthorised use, reproduction or distribution of this document or the information contained in it, by anyone other than CAREL, is severely forbidden. All data refer to year 2017