The document outlines GMP requirements related to personnel, training, hygiene, premises design and layout, warehouse, production and auxiliary areas, and quality control. It emphasizes that facilities, equipment, and personnel must be suitable for manufacturing pharmaceutical products and maintaining quality. Key responsibilities are defined for heads of production and quality units to ensure compliance with GMP standards.
Cara Menggugurkan Kandungan Secara Alami 3 Jam Tuntas
GMP REQUIREMENTS
1. GMP REQUIREMENTS
Dr. K. VENKATESWARA RAJU
SHRI VISHNU COLLEGE OF PHARMACY
mail4venkey@gmail.com
2. PERSONNEL
GENERAL
RESPONSIBILITIES OF HEAD OF PRODUCTION
RESPONSIBILITIES OF HEAD OF THE QUALITY UNIT
PERSONNEL RECORDS
TRAINING
HYGIENE
PREMISES- DESIGN, CONSTRUCTION AND LAYOUT
LOCATION OF FACTORY
BUILDINGS AND PREMISES
PRODUCTION / AUXILIARY AREAS
QUALITY CONTROL
MAINTAINANCE
SANITATION IN MANUFACTURING AREA
ENVIRONMENTAL CONTROL
UTILITIES
PLUMBING
DRAINAGE SYSTEMS
GAS SYSTEMS
WATER SYSTEM
WATER SYSTEM- TYPES OF WATER
MAINTAINANCE OF STERILE AREAS
CONTROL OF CONTAMINATION
EQUIPMENT
RAW MATERIALS
3. 3
GMP and SCHEDULE-M
The basic responsibility of a manufacturer is to ensure the
production of quality products
These quality objectives can be achieved by GMP and hence they
were implemented as Schedule M in 1988.
The Schedule M has again been amended in a major way by the
drugs and cosmetics act rules,2001
4. 4
GMP and SCHEDULE-M
Requirement of factory premises ,plant and equipment for
manufacturing drugs and pharmaceutical products.
M-1: Requirement of factory premises for the manufacture of
homeopathic preparations.
M-2: Requirement of factory premises for the manufacture of
cosmetics.
M-3:Requirement of factory premises for the manufacture of
medical devices
5. 5
PART 1-GMP FOR PREMISES AND MATERIALS
Part1-A:Specific requirements for manufacture of sterile products,
parenteral preparations & sterile ophthalmic preparations.
Part1-B:Specific requirements for manufacture of oral solid dosage
forms (tablets and capsules).
Part1-C:Specific requirements for manufacture of oral liquids (syrups,
emulsions, suspensions, elixirs, etc)
6. 6
PART 1-GMP FOR PREMISES AND MATERIALS
Part1-D:Specific requirements for manufacture of topical products.
Part1-E:Specific requirements for manufacture of metered dose
inhalers.
Part 1-F: Specific requirement of premises, plant and materials for
the manufacture of active pharmaceutical ingredients (bulk drugs)
8. 8
PERSONNEL - GENERAL
The establishment and maintenance of a satisfactory system of QA and the correct
manufacture and control of pharmaceutical products and active ingredients rely upon
people.
For this reason there must be sufficient qualified personnel to carry out all the tasks for
which the manufacturer is responsible.
Individual responsibilities should be clearly defined and understood by the persons
concerned and recorded as written descriptions.
The manufacturer should have an adequate number of personnel with the necessary
qualifications and practical experience. The responsibilities placed on any one individual
should not be so extensive as to present any risk to quality.
Responsible staff should have its specific duties recorded in written descriptions and
adequate authority to carry out its responsibilities. Its duties may be delegated to designated
deputies with a satisfactory level of qualifications. There should be no gaps or unexplained
overlaps in the responsibilities of personnel concerned with the application of GMP. The
manufacturer should have an organization chart.
All personnel should be aware of the principles of GMP that affect them and receive initial
and continuing training, including hygiene instruction, relevant to their needs. All personnel
should be motivated to support the establishment and maintenance of high quality
standards.
Steps should be taken to prevent unauthorized people from entering production, storage
and QC areas. Personnel who do not work in these areas should not use them as a
passageway.
9. 9
PERSONNEL - GENERAL
The company to have competent staff with experience and educational
qualifications
The head of QC/ QA should be independent of production
Approved technical staff to be available for testing
Adequate staff to be provided for both quality assurance and control activities
Job responsibilities have to be clearly laid down
Sufficient QC personnel to carry out the work
QC, Production, Store and other personnel to receive technical training in line
with their duties
10. 10
PERSONNEL - GENERAL
Key personnel include the heads of production, the head(s) of quality unit(s)
and the authorized person. The quality unit(s) typically comprise the quality
assurance and quality control functions. In some cases, these could be
combined in one department. The authorized person may also be
responsible for one or more of these quality unit(s). Normally, key posts
should be occupied by full-time personnel. The heads of production and
quality unit(s) should be independent of each other. In large organizations,
it may be necessary to delegate some of the functions; however, the
responsibility cannot be delegated.
Key personnel responsible for supervising the production and quality unit(s)
for pharmaceutical products should possess the qualifications of a scientific
education and practical experience required by national legislation
They should also have adequate practical experience in the manufacture
and QA of pharmaceutical products. In order to gain such experience, a
preparatory period may be required, during which they should perform
their duties under professional guidance.
11. 11
PERSONNEL
THE HEAD OF PRODUCTION GENERALLY HAS THE FOLLOWING
RESPONSIBILITIES
(a) to ensure that products are produced and stored in accordance with the
appropriate documentation in order to obtain the required quality;
(b) to approve the instructions relating to production operations, including the in-
process controls, and to ensure their strict implementation;
(c) to ensure that the production records are evaluated and signed by a
designated person;
(d) to check the maintenance of the department, premises and equipment;
(e) to ensure that the appropriate process validations and calibrations of control
equipment are performed and recorded and the reports made available;
(f) to ensure that the required initial and continuing training of production
personnel is carried out and adapted according to need.
12. 12
PERSONNEL
THE HEAD OF QUALITY UNIT(S) GENERALLY HAVE THE FOLLOWING
RESPONSIBILITIES
(a) to approve or reject starting materials, packaging materials, and intermediate, bulk
and finished products in relation to their specifications;
(b) to evaluate batch records;
(c) to ensure that all necessary testing is carried out;
(d) to approve sampling instructions, specifications, test methods and other QC
procedures;
(e) to approve and monitor analyses carried out under contract;
(f) to check the maintenance of the department, premises and equipment;
(g) to ensure that the appropriate validations, including those of analytical procedures,
and calibrations of control Equipment are carried out;
(h) to ensure that the required initial and continuing training of quality unit personnel is
carried out and adapted according to need;
(i) establishment, implementation and maintenance of the quality system;
(j) supervision of the regular internal audits or self-inspections;
(k) participation in external audit (vendor audit);
(l) participation in validation programmes.
13. 13 PERSONNEL - PERSONNEL RECORDS
The manufacturer must have an organization chart.
People in responsible positions should have specific duties recorded in
written job descriptions and adequate authority to carry out their
responsibilities. Their duties may be delegated to designated deputies
of a satisfactory qualification level.
Documents need to be designed, prepared and reviewed and
controlled
Documents have to be such that they permit an audit trail
All documents have to be prepared as per rules
Documents need to be approved, signed and dated by authorized
personnel
15. 15
TRAINING
The manufacturer should provide training in accordance with a written programme for all
personnel whose duties take them into manufacturing areas or into control laboratories
(including the technical, maintenance and cleaning personnel) and for other personnel as
required.
Besides basic training on the theory and practice of GMP, newly recruited personnel
should receive training appropriate to the duties assigned to them.
Continuing training should also be given, and its practical effectiveness periodically
assessed. Approved training programmes should be available.
Training records should be kept.
Personnel working in areas where contamination is a hazard, e.g. clean areas or areas
where highly active, toxic, infectious or sensitizing materials are handled, should be given
specific training.
The concept of QA and all the measures which aid its understanding and implementation
should be fully discussed during the training sessions.
Visitors or untrained personnel should preferably not be taken into the production and
QC areas. If this is unavoidable, they should be given relevant information in advance
(particularly about personal hygiene) and the prescribed protective clothing. They should
be closely supervised.
Consultant and contract staff should be qualified for the services they provide. Evidence
of this should be included in the training records.
17. 17
HYGIENE
All personnel, prior to and during employment, as appropriate, should undergo health
examinations. Personnel conducting visual inspections should also undergo periodic eye
examinations.
All personnel should be trained in the practices of personal hygiene. A high level of personal
hygiene should be observed by all those concerned with manufacturing processes. In particular,
personnel should be instructed to wash their hands before entering production areas. Signs to
this effect should be posted and instructions complied with.
Any person shown at any time to have an apparent illness or open lesions that may adversely
affect the quality of products should not be allowed to handle starting materials, packaging
materials, in-process materials or medicines until the condition is no longer judged to be a risk.
All employees should be instructed and encouraged to report to their immediate supervisor any
conditions (relating to plant, equipment or personnel) that they consider may adversely affect
the products.
Direct contact should be avoided between the operator’s hands and starting materials, primary
packaging materials and intermediate or bulk product.
To ensure protection of the product from contamination, personnel should wear clean body
coverings appropriate to the duties they perform, including appropriate hair covering. Used
clothes, if reusable, should be stored in separate closed containers until properly laundered and,
if necessary, disinfected or sterilized.
Smoking, eating, drinking, chewing, and keeping plants, food, drink, smoking material and
personal medicines should not be permitted in production, laboratory and storage areas, or in
any other areas where they might adversely influence product quality.
Personal hygiene procedures, including the wearing of protective clothing, should apply to all
persons entering production areas, whether they are temporary or full-time employees or non-
employees, e.g. contractors, employees, visitors, senior managers and inspectors
19. 19
PREMISES- DESIGN, CONSTRUCTION AND LAYOUT -
GENERAL
Principle. Premises must be located, designed, constructed, adapted and maintained to suit the
operations to be carried out.
The layout and design of premises must aim to minimize the risk of errors and permit effective
cleaning and maintenance in order to avoid cross-contamination, build-up of dust or dirt, and in
general, any adverse effect on the quality of products.
Where dust is generated (e.g. during sampling, weighing, mixing and processing operations, or
packaging of powder), measures should be taken to avoid cross-contamination and facilitate cleaning.
Premises should be situated in an environment that, when considered together with measures to
protect the manufacturing process, presents minimum risk of causing any contamination of materials
or products.
Premises used for the manufacture of finished products should be suitably designed and constructed
to facilitate good sanitation.
Premises should be carefully maintained, and it should be ensured that repair and maintenance
operations do not present any hazard to the quality of products.
Premises should be cleaned and, where applicable, disinfected according to detailed written
procedures. Records should be maintained.
Electrical supply, lighting, temperature, humidity and ventilation should be appropriate and such that
they do not adversely affect, directly or indirectly, either the pharmaceutical products during their
manufacture and storage, or the accurate functioning of equipment.
Premises should be designed and equipped so as to afford maximum protection against the entry of
insects, birds or other animals. There should be a procedure for rodent and pest control.
Premises should be designed to ensure the logical flow of materials and personnel
20. 20
Location of factory
No open sewers or public lavatory and drain in the proximity
No factory producing soot or obnoxious odour / dust/ smoke and
biological emissions in the proximity
Buildings and premises
Free from contamination because of other activities
Adequate provision of working space
Cross contamination and contamination avoided
Adequate pest control measures taken
Provided with Air conditioning, AHUs as applicable
There has to be a comfort level for all those working in the area
Drainages are constructed such that there is no Room for entry of insects
Walls and floors to be free from cracks and open joints. All interior surfaces should
not shed any particles. No accumulation of waste can take place
Floors and walls are smooth and impervious
22. 22
Warehouse
Space for storage of raw materials, packaging materials, intermediates, finished products,
products in quarantine, rejected materials, rejected products provided for
Access to storage areas should be restricted to authorized personnel
Storage conditions adequate
Special conditions provided where required
Records are maintained of storage conditions
Satisfactory Storage area- House keeping to prevent any attack of pests
Receiving and dispatch areas to be closed to protect materials
Incoming materials to be cleaned prior to shifting to storage area
Quarantine areas are well demarcated
Sampling area provided for actives and excipients separately
Segregated areas provided for storages for rejected, recalled and returned products
Areas provided for narcotics, poisonous, hazardous substances etc
Printed packaging materials stored under lock and key in a secure area
All primary packaging materials are received in a closed condition to prevent
contamination during storage
Dispensing areas separate for Beta lactum and Hormonal and other special products
under special conditions to prevent cross contamination
Dispensing and sampling areas separate for sterile products under Class 100 conditions
(grade A )
Adequate precautions to be taken to prevent breakage, spillage and leakage of
containers
24. 24 Production areas
Production area allows uni-directional flow of process
Production of Penicillin and biological preparations to be
segregated
Areas for potent products such as betalactum or sex hormones to
be separated from other areas
Pipelines, electrical fittings and ventilation openings shall be
constructed to avoid creation of recesses
Service lines to be identified by colour codes and flow directions
indicated
25. 25 Auxiliary areas
Rest rooms to be separated from other areas. They cannot lead
directly to production area
Change rooms and facilities therein to be commensurate with
number of workforce
Maintenance workshops to be located away from main work areas
Spares and tooling to be stored in production area have to be kept in
dedicated rooms or lockers
Animal houses to be separated from other manufacturing areas and
shall be in line provisions on the Act
27. 27 Quality control
QC laboratory to be independent of other production areas
Provision to be made for chemical, instrumental, Microbiological and
radio isotope analysis
Adequate steps to be taken to prevent cross contamination/
contamination during analysis
A separate instrument room is to be provided with adequate facilities
Sufficient area to be provided for storage of test samples, retained
samples, reagents etc
Air locks and LAF benches to be provided for Microbiological
laboratory
28. 28
MAINTAINANACE
MAINTENANCE
Maintenance , literally means ‘The Process or Practice of keeping something in good condition’. I pharmaceutical industries as per
various regulatory bodies maintenance says - “Any building used in the manufacture, processing, packing, or holding of a drug
product shall be maintained in a good state of repair”.
DEFICIENCIES IN MAINTENANCE
The most important lacunas or illegibility or deficiencies that should be avoided in industries are :
1. Buildings under deterioration state
2. Cracks and holes on walls , floors and ceilings.
3. Deep floor cracks
4. Ingress of water from roof leaks
5. Holes in roofs or top of buildings
6. Damage to insulation or pipes
7. Light fittings
8. Improper building inspection and maintenance programs.
THE IMPACTS OF THESE DEFICIENCIES
The impacts of these deficiencies; Buildings under deterioration state: Deterioration of buildings not only presents a poor
image of the facility, it can also impact on product quality. Cracks and holes on walls, floors and ceilings: Cracks and holes in
walls, floors, or ceilings can provide access for insects, rodents, birds, dirt, or microorganisms. They can also hinder cleaning
and sanitation, thereby increasing the potential for cross contamination or microbial multiplication.
IMPORTANCE OF PROPER MAINTENANCE
Importance of proper maintenance Avoidance of contamination. Good product quality can be obtained. Accidents can be
avoided. Systematic and smooth functioning of the industry. Safety can be enhanced.
29. 29
MAINTAINANACE
Maintenance Classification
1. Corrective or Breakdown Maintenance
2. Scheduled Maintenance
3. Preventive Maintenance
4. Predictive Maintenance
1. Corrective Or Breakdown Maintenance
“Repairs that are made after the equipment is out of order and it cannot perform it’s normal function
any longer”
Eg: Electric Motor will not start
Used in small factories which get temporary Demand in excess of normal operating capacity
Causes For Equipment Breakdown
i. Failure to replace worn out parts
ii. Lack of Lubrication
iii. Neglected Cooling System
iv. External Factors
v. Indifference towards minor faults
vi. Indifference towards major faults
Advantages of Breakdown Maintenance
I. Lower Initial Costs
II. Requires Fewer Staff
III. No Planning Needed
30. 30
MAINTAINANACE
Disadvantages of Breakdown Maintenance
I. Reduction of Output
II. Faster Plant Deterioration
III. Increased Chances of Accidents
IV. More Spoilt Material
V. Direct Loss of Profit
VI. Breakdown at Inopportunate Times
VII. Plant Items Regulated by Statutory Provisions are not subject to breakdown
maintenance
2. Scheduled Maintenance
Aim: Avoiding Breakdown
Scheduled maintenance incorporates:
I. White washing of buildings
II. Overhauling of machines
III. Repair
IV. Cleaning Of Water & Other Tanks
31. 31
MAINTAINANACE
3. Preventive Maintenance
Principle: Prevention is better than cure
PM should not be done for the entire plant at once
It is better to tackle one department or machinery at a time
The entire PM programme hangs on inspections and their related duties of adjustments and
repairs
Aims at minimizing the problems of breakdown maintenance
Locates Weak Spots
Provides Regular inspection
Initiates minor repairs thereby reducing the risk of unanticipated breakdown
Minimizing the possibility of unanticipated production interruption.
4. Predictive Maintenance
1. New technique
2. Extends service life of equipment without failure
3. Makes use of human or other sensitive instruments like:
Pressure
Amplitude meters
Temperature
Audio Gauges
33. 33
SANITATION IN MANUFACTURING AREA
Self contained facilities need to be provided for specific products
Manufacturing areas need to be cleaned and maintained and
should be free from debris, dust etc.
During manufacture of a product, the manufacturing area should
be used for the product manufactured only and not used as a
passage
There need to be a routine sanitation programme
There is a need for an SOP for the same giving all details
It has to specify the area to be cleaned and the frequency
34. 34 SANITATION IN MANUFACTURING AREA
The procedure has to specify the cleaning agent including
equipment and tools to be used along with frequency
The procedure has to assign the responsibility to a person for
cleaning
The production processes have to be logically placed to avoid
contamination between products
Provision has to be made for adequate Lighting in production
areas to be provided to carry out the activity, especially where
visual checks are carried out
Records need to be kept of cleaning and sanitation
36. 36
HEALTH, CLOTHES AND SANITATION
Personnel handling Betalactum products have to be tested for Penicillin
sensitivity
Personnel handling potent and cytotoxic’s and sex hormones to be tested for
adverse effects periodically
These personnel have to be rotated, as a health safeguard
Personnel have to be examined at the time of employment for eyesight and
absence from TB.
They have to be free from skin infections and other communicable diseases and
a record should be available of these aspects.
A qualified physician is to be made available for assessing the health of
personnel
Personnel have to be trained in Personal hygiene
Instructions have to be displayed on personal hygiene
37. 37
HEALTH, CLOTHES AND SANITATION
Employees to be told to report any apparent illness or skin lesions in order
to protect the products from any kind of risk
Employees to be instructed to report any adverse change in their health
Personnel have to wear protective clothing and such other gears to protect
the product from direct contact
Employees in certain specific areas wear single suits where required
Change rooms adequate in size have to be provided
Change rooms should have independent cabinets to store their street as well
as factory dresses
Facilities such as soap, disinfectants, dryers to be provided in these rooms
Smoking, drinking, chewing is to be strictly prohibited in work areas and
restricted to identified areas
38. 38
ENVIRONMENTAL CONTROL
Environmental control of pharmaceutical cleanrooms is essential to the
manufacture of a quality product.
Control of such conditions as airborne particulate, microorganisms, temperature ,
humidity, differential pressure, airflow, air velocity and personnel is crucial to
protect the product from contamination.
Therefore, the design, validation and ongoing monitoring of a cleanroom
HVAC system are necessary to assure the quality and safety of the pharmaceutical
product.
The manufacturing environment is critical for product quality and includes
1. Light
2. Temperature
3. Humidity
4. Air movement
5. Microbial contamination
6. Particulate contamination
Uncontrolled environment can lead to product degradation
product contamination
loss of product and profit
40. 40
ENVIRONMENTAL CONTROL
A Heating system (“H” in HVAC)
A Ventilating system (“V” in HVAC)
A Cooling system (“AC" in HVAC)
HVAC systems can increase or decrease temperature, increase or reduce the
moisture or humidity in the air, decrease the level of particulate or gaseous
contaminants in the air. These abilities are employed for comfort and to
protect people and product.
HVAC; Heating, Ventilation and Air conditioning – Validated Yearly by
external party
Parameters:
1. Temperature
2. Air velocity
3. Air Changes
4. Filter integrity
5. Non-viable air borne particles
6. Viable air borne particles
43. UTILITIES
Qualification of utilities that could impact on product quality
e.g. steam, gases, compressed air, HVAC,water
Monitoring and action in case of OOL
Drawings for these utility systems should be available
Adequate ventilation, air filtration and exhaust systems and drainage
systems where appropriate
Designed and constructed to minimize risks of contamination and
cross-contamination
44. UTILITIES - PLUMBING
Potable water shall be supplied under continuous positive pressure in a plumbing
system free of defects that could contribute contamination to any drug product.
The pipes and fittings must be of quality good enough to withstand the pressure
and heat conditions.
Metals are often included in pharmaceutical facility waste water permitting
criteria but are not commonly a discharge issue. Compatibility of the materials of
construction with the characteristics of the waste water must be considered
during the design of the facility. For example: Copper plumbing should not be
used in drain line for acidic waste water because it might fail from corrosion but
also may result in waste water discharge above copper concentration limits.
The pipes should be color coded according to the material it carries.
Grey ------------------------ Raw water
Orange ----------------- Distilled Water
Green --------------------Cooling water
Insulated----------------- Steam
White------------------------ Air
45. UTILITIES- DRAINAGE SYSTEMS
They remove effluent from spaces, systems, or process.
Drains shall be of adequate size and, where, connected directly to sewer, shall be
provided with an air break or other mechanical device to prevent back-siphon age.
They should be easy to clean. And they must be cleaned at a proper interval. They must
be well closed and air tight.
For biological waste, it should be treated in a proper manner before disposal to not to
harm the environment.
Dissolved oxygen content in waste to be disposed in lake or river must be within limits
TYPES
- Sanitary waste system
- Laboratory waste system
- Process Waste System
- Hazardous Material Waste and Retention
- Storm Drainage System
46. 46
UTILITIES - GAS SYSTEMS
Many types of gases are utilized in the manufacturing process. The most prevalent of these include
compressed air use in process and controls, breathing air for hazardous environments, nitrogen,
vacuum, vacuum cleaning, natural gas, propane, and other process systems. All gases used in
manufacturing and processing operations, including the sterilization process, should be sterile
filtered at points of use to meet the requirements of the specific area. Gases to be used in sterilizers
after the sterilization or used at the filling line or microbiological testing area must also be sterile
filtered
All gases used in manufacturing and processing operations, including sterilization process
COMPRESSED AIR
In general compressed air should be supplied by an “oil- free” type compressor and
must be free of oil and oil vapour unless vented directly to a noncontrolled environment area.
It should also be dehumidified to prevent condensation of water vapor.
BREATHING AIR
Breathing air is generally provided for use to personnel working in hazardous environment.
Provided centrally through a breathing air distribution system or at the local level with “backpack” type
breathing air units worn by each person.
NITROGEN
Used for the purging of electrical equipment in volatile or explosive environments
VACUUM
Vacuum is utilized in the encapsulation and tablet compression areas.
VACUUM CLEANING
For dry particulate and powder pickup.
47. 47
UTILITIES - Water system
Water is most widely used material in pharmaceutical manufacturing. A greater
volume of water is used in cleaning and rinsing processes than in formulation in
most facilities. Regardless of the water volume used in actual drug formulation ,
all pharmaceutical water is subject to cGMPs even when the water does not
remain in the finished product.
Potable water available as per BIS
Purified water produced should comply with IP
Stored water adequately protected to prevent microbiological contamination
Storage tanks are cleaned and records maintained
Water purified has to be kept in circulation to prevent microbial buildup
Demonstrate that water used is suitable for its intended use
At minimum - WHO guidelines for drinking (potable) water quality
Other chemical and/or microbiological water quality specifications can be used -
appropriate specifications for physical and chemical attributes, total microbial
counts, objectionable organisms and/or endotoxins established
Validated water treatment process: water monitored with appropriate action
limits
48. 48
WATER SYSTEM- TYPES OF WATER
A) POTABLE WATER (drinking water) - being the source for obtaining various higher
qualities of water, adequate pretreatment are essential before it is used. It may be used for
synthesis of active ingredients and also used for cleaning of equipment's and facilities.
B) PURIFIED WATER - This water is used in preparation of non-parenteral dosage forms.
Bacteria should not be more than100 cfu/ml
C) WATER FOR INJECTION (WFI) - It is used in parenteral products. In bulk, this type of
water is also called Pyrogen free water or PFU and if it is sterilized, it is called sterile WFI.
Bacteria should not be more than10 cfu/100 ml. Storage time for all water must be less than
24 hrs. unless stored at 80°C.
D) SOFTENED WATER - which has its Calcium and Magnesium removed. Such a water can
be used e.g. for first washing steps. Certain processes require special well-defined qualities
of water.
E) CLEAN STEAM is a form of water that may be used for sterilization purpose and prepared
from deionized water.
F) WATER FOR FINAL RINSE is used for rinsing equipment after washing. It must be of the
same quality as the water used for manufacturing the product.
G) STERILE WATER FOR INJECTION water for injection which is sterilized within 12 hours
of collection and distributed in sterile containers. It is intended mainly for use as a solvent
for injectable preparations such as powders for injection that are distributed dry because of
limited stability of their solutions. It should be packaged only in single dose containers of
not larger than 1-litre size.
H) BACTERIOSTATIC WATER FOR INJECTION
49. 49
MAINTAINANCE OF STERILE AREAS
The production of sterile preparations should be carried out in clean areas, entry to which should be through
airlocks for personnel and/or for equipment and materials. Clean areas should be maintained to an
appropriate standard of cleanliness and supplied with air that has passed through filters of the required
efficiency.
The various operations of component preparation (such as those involving containers and closures), product
preparation, filling and sterilization should be carried out in separate areas within a manufacturing suite.
These areas are classified into four grades.
Manufacturing operations are divided here into two categories: first, those where the product is terminally
sterilized, and second, those which are conducted aseptically at some or all stages.
The sanitation of clean areas is particularly important. They should be cleaned frequently and thoroughly in
accordance with an approved written program. Monitoring should be regularly undertaken in order to
detect the contamination or the presence of an organism against which the cleaning procedure is ineffective.
In view of its limited effectiveness, ultraviolet light should not be used as a substitute for chemical
disinfection. Where disinfectants are used more than one type should be employed.
Disinfectants and detergents should be monitored for microbiological contamination; dilutions should be
kept in previously cleaned containers and should only be stored for defined periods unless sterilized.
Disinfectants and detergents used in grade A and B areas should be sterile before use.
A disinfectant program should also include a sporicidal agent since many common disinfectants are
ineffective against spores. Cleaning and disinfectant procedures should be validated.
In order to control the microbiological cleanliness of the cleanliness grades A-D in operation, the clean areas
should be monitored. Where aseptic operations are performed, monitoring should be frequent and methods
such as settle plates and volumetric air and surface sampling (e.g. swabs and contact plates) should be used.
The zones should not be contaminated through the sampling methods used in the operations. The results of
monitoring should be considered when batch documentation for release of the finished product is reviewed.
Both surfaces and personnel should be monitored after critical operations.
Levels (limits) of detection of microbiological contamination should be established for the purpose of
setting alert and action levels, and for monitoring the trends in environmental cleanliness in the facility.
50. 50
MAINTAINANCE OF STERILE AREAS
For the manufacture of sterile pharmaceutical preparations, four grades are
distinguished
here, as follows:
Grade A: The local zone for high-risk operations, e.g. filling and making aseptic
connections. Normally such conditions are achieved by using a unidirectional
airflow workstation
Grade B: In aseptic preparation and filling, the background environment for the
grade A zone.
Grades C and D: Clean areas for carrying out less critical stages in the manufacture
of sterile
products.
In order to reach the B, C and D air grades, the number of air changes should be
appropriate for the size of the room and the equipment and personnel present in
it.
HEPA filters should be subjected to installed filter leakage test in accordance with
ISO 14644-3 at least twice a year. The purpose of performing regular leak tests is
to ensure the filter media, filter frame, and filter seal are free from leaks. The
aerosol selected for HEPA leak testing should not support microbial growth and
should be composed of a sufficient number or mass of particles.
51. 51
MAINTAINANCE OF STERILE AREAS
Clean room and clean air device classification
Clean rooms and clean air devices should be classified in accordance with EN ISO
14644.
Maximum permitted airborne particle concentration for each grade is given
below.
52. 52
CONTROL OF CONTAMINATION
When dry materials and products are used in production, special precautions should be
taken to prevent the generation and dissemination of dust. Provision should be made
for proper air control (e.g. supply and extraction of air of suitable quality)
Contamination of a starting material or of a product by another material or product
must be avoided. This risk of accidental cross-contamination arises from the
uncontrolled release of dust, gases, particles, vapours, sprays or organisms from
materials and products in process, from residues on equipment, from intruding insects,
and from operators’ clothing, skin, etc.
The significance of this risk varies with the type of contaminant and of the product
being contaminated. Among the most hazardous contaminants are highly sensitizing
materials, biological preparations such as living organisms, certain hormones, cytotoxic
substances, and other highly active materials. Products in which contamination is likely
to be most significant are those administered by injection or applied to open wounds
and those given in large doses and/or over a long time.
53. 53
CONTROL OF CONTAMINATION
Cross-contamination should be avoided by taking appropriate technical or organizational measures, for
example:
(a) carrying out production in dedicated and self-contained areas (which may be required for
products such as penicillin's, live vaccines, live bacterial preparations and certain other biologicals);
(b) conducting campaign production (separation in time) followed by appropriate cleaning in
accordance with a validated cleaning procedure;
(c) providing appropriately designed airlocks, pressure differentials, and air supply and extraction
systems;
(d) minimizing the risk of contamination caused by recirculation or reentry of untreated or
insufficiently treated air;
(e) wearing protective clothing where products or materials are handled;
(f) using cleaning and decontamination procedures of known effectiveness;
(g) using a “closed system” in production;
(h) testing for residues;
(i) using cleanliness stat
Measures to prevent cross-contamination and their effectiveness should be checked periodically
according to SOPs.
Production areas where susceptible products are processed should undergo periodic environmental
monitoring (e.g. for microbiological and particulate matter, where appropriate).us labels on equipment.
55. 55
EQUIPMENT
Equipment must be located, designed, constructed, adapted and maintained to suit the operations to be
carried out. The layout and design of equipment must aim to minimize the risk of errors and permit effective
cleaning and maintenance in order to avoid cross-contamination, build-up of dust or dirt, and, in general, any
adverse effect on the quality of products.
Equipment should be installed in such a way as to minimize any risk of error or of contamination.
Fixed pipework should be clearly labelled to indicate contents and, where applicable, the direction of flow.
All service pipework and devices should be adequately marked and special attention paid to the provision of
non-interchangeable connections or adaptors for dangerous gases and liquids.
Balances and other measuring equipment of an appropriate range and precision should be available for
production and control operations and should be calibrated according to a fixed schedule.
Production equipment should be thoroughly cleaned according to a fixed schedule.
Laboratory equipment and instruments should be suited to the testing procedures undertaken.
Washing, cleaning and drying equipment should be chosen and used so as not to be a source of contamination.
Production equipment should not present any hazard to the products.
The parts of the production equipment that come into contact with the product must not be reactive, additive,
or absorptive to an extent that would affect the quality of the product.
Defective equipment should be removed from production and QC areas. If this is not possible, it should be
clearly labelled as defective to prevent use.
Closed equipment should be used whenever appropriate. Where open equipment is used or equipment is
opened, precautions should be taken to minimize contamination.
Non-dedicated equipment should be cleaned according to validated cleaning procedures between being used
for production of different pharmaceutical products to prevent cross-contamination.
Current drawings of critical equipment and support systems should be maintained.
56. 56 EQUIPMENT
Equipment should be so designed so as to have suitable
maintenance and operations as per product requirements
The layout should be suitable to facilitate effective cleaning
and maintenance in order to avoid cross contamination
Balances and such other measuring devices to be available
in raw material stores and in-process areas
57. 57 EQUIPMENT
These need to be calibrated as per SOP and records
maintained
The material of construction of equipment should be such
that they do not react with the product to be manufactured
and do not contaminate the product
Edible and food grade lubricants have to be used in
equipment wherever required
Defective equipment have to be removed from the areas
where possible and labeled
59. 59 RAW MATERIALS
Inventories of raw materials need to be kept and
records maintained as per Schedule “U” of D&C Act
Raw materials need to be quarantined upon receipt
Raw materials segregated and FIFO followed and
where applicable FEFO
60. 60 RAW MATERIALS
All vouchers have to be made available for purchase of raw materials
and procured from approved vendors (for critical materials)
The documents have to show whether the RAW materials are
purchased from manufacturers or suppliers
Authorized personnel from QC need to examine all raw materials for
integrity of pack
Damaged containers need to be segregated, identified and recorded
If more than one batch is present in a consignment, it is to be
considered separately for testing and approval
61. 61 RAW MATERIALS
Raw material containers have to be labeled for name of
product, any code reference, manufacturer’s name address,
supplier’s name address, batch number, status (quarantine,
under test and approved/ rejected), manufacturing date,
expiry date and re-test dates
Areas have to be made available for “Quarantine”, “under
test”, “approved” & “rejected” segregated and partitioned in
order to have clear identity of status
In case the quantity of raw material is too large, a mobile
system may be followed
62. 62 RAW MATERIALS
“Sampled ” containers need to be labeled
If there is any material accepted based on
manufacturer’s certificate of analysis, the
manufacturer needs to be audited and
documentation should be available justifying such
acceptance
All materials to be stored off the floor on pallet or
rack
It has to be ensured that the shelf life of product
does not exceed the shelf life of raw materials
63. 63
RAW MATERIALS
The purchase of starting materials is an important operation that should involve
staff who have a particular and thorough knowledge of the products and
suppliers.
Starting materials should be purchased only from approved suppliers and,
where possible, directly from the producer. It is also recommended that the
specifications established by the manufacturer for the starting materials be
discussed with the suppliers. It is beneficial for all critical aspects of the
production and control of the starting material in question, including handling,
labelling and packaging requirements as well as complaints and rejection
procedures, to be contractually agreed between the manufacturer and the
supplier.
For each consignment, at a minimum, the containers should be checked at least
for integrity of package and seal and for correspondence between the order, the
delivery note, and the supplier’s labels.
All incoming materials should be checked to ensure that the consignment
corresponds to the order. Containers should be cleaned where necessary and
labelled, if required, with the prescribed information. Where additional labels
are attached to containers, the original information should not be lost.
64. 64
RAW MATERIALS
Damage to containers and any other problem that might adversely affect the quality of a material
should be recorded and reported to the QC department and investigated.
If one delivery of material is made up of different batches, each batch must be considered as
separate for sampling, testing and release.
Starting materials in the storage area should be appropriately labelled.
Labels should bear at least the following information:
(a) the designated name of the product and the internal code reference where applicable;
(b) the batch number given by the supplier and, on receipt, the control or batch number given by the
manufacturer, if any, documented so as to ensure traceability;
(c) the status of the contents (e.g. in quarantine, on test, released, rejected, returned, recalled);
(d) where appropriate, an expiry date or a date beyond which retesting is necessary. When fully
validated computerized storage systems are used, not all of the above information need be in a legible
form on the label.
There should be appropriate procedures or measures to ensure the identity of the contents of
each container of starting material. Bulk containers from which samples have been drawn should
be identified.
Only starting materials released by the QC department and within their shelf-life should be used.
Starting materials should be dispensed only by designated persons, following a written procedure,
to ensure that the correct materials are accurately weighed or measured into clean and properly
labelled containers.
Each dispensed material and its weight or volume should be independently checked and the check
recorded.
Materials dispensed for each batch of the final product should be kept together and conspicuously
labelled as such.