This document contains drawings and notes for a proposed new dwelling and outbuilding. It includes a ground floor plan drawing with dimensions and notes specifying materials for various rooms. It also includes general notes about drainage, glazing, brickforce placement, and compliance with building regulations. Dimensions and levels must be checked on site before commencing any building work.
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
Proposed new dwelling and outbuilding plans
1. GSPublisherVersion 4.0.100.92
GSEducationalVersion
Project No. Sheet No.
Scale Date Drawn
Drawing Title
Revision No.
Client
Project Title
AS SHOWN TM
0/0
PROPOSED NEW DWELLING
AND OUT-BUILDING
CONTRACTOR DRAWINGS
This drawing is the property of KNV Architects COPYRIGHT
is reserved by KNV Architects, and this drawing is issued
on the condition that it is not copied, reproduced, retained or
disclosed to any unauthorised person, either wholly or in part,
without the written consent of KNV Architects
ALL DIMENSIONS, DEPTHS OF EXCAVATIONS, NUMBER
OF STEPS, HEIGHTS OF PLINTHS AND LEVELS TO BE
CHECKED ON SITE, PRIOR TO COMMENCING OF ANY
BUILDING WORK.
DRAWINGS NOT TO BE SCALED. REFER TO DIMENSIONS
NOTES:
GLASS THICKNESS MAX. AREA m2
3mm
4mm
5mm
0.0 - 0.75m2
0.75 - 1.5m2
1.5 - 2.1m2
* SLIDING DOORS : SAFETY GLASS
* ALL ROOMS TO HAVE
CLEAR GLASS
* BATHROOMS & TOILETS TO
HAVE OBSCURE GLASS
TO USE
*
*
* BALLUSTRADES & HANDRAILS:
DRAINAGE NOTES:
* ALL DRAINAGE TO COMPLY WITH PART 'P' OF THE NATIONAL
BUILDING REGULATIONS
* I.E.'s TO ALL CONNECTIONS.
* R.E.'s AT CHANGE OF DIRECTION AND MARKED COVERES AT
GROUND LEVEL.
* DRAIN PIPES EXCEEDING 6m TO JUNCTIOIN TO HAVE OWN
100mm_ O.V.P.
* WASTE PIPES- 50mm_, SEWER PIPES- 100mm_
* WHERE DRAINAGE OCCURS UNDER FOUNDATIONS AND CONCRETE
FLOOR SLABS, PIPES TO BE ENCASED IN 100mm THICK CONCRETE
AND NOT DEVIATE FROM STRAIGHT LINE, WITH I.E.'s EITHER
SIDES.
* MINIMUM INVERT LEVEL OF DRAIN : 450mm
* 100mm DIA. V.P. AT HEAD OF DRAIN WITH 110mm AIRVALVE.
* WHERE ONE-PIPE SYSTEM IS APPLIED, ANTI-SYPHON VENT PIPES
TO BE 50mm_
* MIN. FALL OF DRAIN- 1:40, MAX. - 1:60
* WHERE FALL OF DRAIN EXCEEDS 1:10, BACK DROPS TO BE
PROVIDED TO ENSURE MAXIMUM FALL OF 1:10
* CONTRACTOR TO PROVIDE CERTIFICATE
* ALL NEW BUILDING WORK TO COMPLY TO THE NATIONAL
BUILDING REGULATIONS.
* ALL DIMENSIONS, DEPTHS OF EXCAVATIONS, NUMBER OF STEPS,
HEIGHTS OF PLINTHS AND LEVELS TO BE CHECKED ON SITE, PRIOR
TO COMMENCING OF ANY BUILDING WORK.
* READ FIGURED DIMENSIONS IN PREFERENCE TO SCALING.
* ALL FINISHES TO OWNER'S APPROVAL.
* OWNER TO BE RESPONSIBLE FOR ALL THE BUILDING WORK
ON THE PROPERTY.
* BRICKFORCE: (UNLESS OTHERWISE NOTED TO TAKE PREFERENCE,I.E NHBRC)
BUILT INTO WALLS 75mm AND 150mm "BRICKFORCE" IN THE
FOLLOWING POSITIONS:
a.) ONE LAYER IN EVERY FIFTH COURSE OF FOUNDATION WALLS & WALLS
b.) ONE COURSE UNDER WINDOW CILLS.
c.) TWO COURSES OVER WINDOW AND DOOR OPENINGS ABOVE LINTELS.
d.) TWO COURSES UNDER WALL PLATE.
* ALL GLAZING TO COMPLY WITH SECTION N OF THE
NATIONAL BUILDING REGULATIONS
* STORM WATER NOTE:
STORM WATERTO BE SURFACE CONTROLLED, IN THE DIRECTION AS
INDICATED ON PLAN, NOT TO BE DISPERSED OF IN CONCENTRATED VOLUMES,
AND TO BE DEPOSITED INTO THE MUNICIPAL SYSTEM TO THE SATSFACTION
OF THE LOCAL AUTHORITY.
- HEIGHT TO BE MINIMUM 1m ABOVE FINISHED FLOOR LEVEL
- NO DIVIDING SPROKETS TO BE FURTHER APARTTHAN 100mm
IN BALLUSTRADES
- BALLUSTRADE BOTTOM RAIL TO BE MAX. 100mm ABOVE
FINISHED FLOOR LEVEL
HOT WATER SERVICES:
* A MIN OF 50% BY VOLUME OF THE ANNUAL AVERAGE HOT WATER HEATING REQUIREMENT
SHALL BE PROVIDED BY MEANS OTHER THAN ELECTRICAL RESISTANCE HEATING, INCLUDING
BUT NOT LIMITED TO, SOLAR HEATING, HEAT PUMPS, HEAT RECOVERY FROM OTHER SYSTEMS
OR PROCESSES.
* THE SOLAR WATER HEATING SYSTEMS SHALL COMPLY WITH SANS 1307 & SANS 10106,
BASED ON THE THERMAL PERFORMANCE DETERMINED IN ACCORDANCE WITH THE
PROVISIONS OF SANS 6211-1 & SANS 6211-2. INSTALLATION SHALL COMPLY TO SANS 10254.
* HOT WATER USAGE SHOULD BE MINIMIZED AND THE SYSTEM MAINTAINED IN ACCORDANCE
WITH THE REQUIREMENTS GIVEN IN SANS 10252-1.
* GEYSER AND ALL EXPOSED PIPES TO AND FROM THE HOT WATER CYLINDERS AND
CENTRAL HEATING SYSTEMS SHALL BE INSULATED WITH INSULATION MATERIAL
WITH AN R-VALUE IN ACCORDANCE WITH SANS 10400.
TO COMPLY TO NBR. AS PER SPECIALIST SPECIFICATIONS.
* SPECIALIST TO PROVIDE CERTIFICATE
KNV
architects
MUGOVHANI
MAY 2017
1
3020
1015 115 1085 115 1730 115
3160
115 1240 115 915 115 2590
4975
2385 1610 980
23039052306452302000115
1550115765
5010
4500
4610 440 2196 440 4537 440
440 4100 440
4975
2990
AA
BIC
BIC
BIC
W1W1
W1
W1
W1
W1
W1
W1 W1
W1 W1
W1
W2
W3
wc
Ø110
whb
Ø55
whb
Ø55
wc
Ø110
W1W1W1
bath
Ø55
wc
Ø110
whb
Ø55
whb
Ø55
shr
Ø55
BIC
W2
W2
W2
W2W2
W2
W2
W3
W3
D1
D2
D2
D2
D2
D3
D3
D2
D2
D4
D5
D2
D6
shr
Ø55
ce
iess & vp
ce ie
ss & vp
il = 450mm
il = 450mm
ce
ie
ce
ie
ce
ie
23060002301700115294511534902301730440
64601700317537202170
17225
230 4150 230 970 115 1615 230 5120 230 6000 230
4610 2700 5350 6460
19120
230323011522001153230115469023011002301145230
346024303230503513301375
16860
19120
230 4150 230 2470 230 5350 230 6000 230
4380 2930 5350 6460
2370 115 765
1470 115 1435 115
4150 115 600
Dining Room
Double Garage
Foyer Bathroom
Bath
room
Bath
room
Kitchen
Scullery
Main Bedroom
Dressing Room
Bedroom 2
Bedroom 1
Family Room
Patio
Covered Patio
carpet
tiles
tiles
tiles
tiles
tiles
tiles
tiles
tiles
tiles
smooth screed
tiles
tiles
carpet
1m
concrete
apron
1m
concrete
apron
1m
concrete
apron
1m
concrete
apron
g
Living Room
tiles
85mm
step up
GROUND FLOOR PLAN
SCALE 1:50