1. 1607
INFORMATION
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
001
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
TRANSMITTAL,
REVISIONS & IMAGES
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100, 1:1, 1:10
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
N
01
0001
4
HC
L4
L1
L2
L5
L6
01
1000
SL 2.800
FCL 2.800
RL 28.000
RL 28.000
RL 28.000
XEGL 28.000
NEGL 28.000
01
1001
01
1000
FFL 28.000
Level 01
door number
RL 28.000
Drawing number on
sheet.
Reference to sheet
that detail is drawn.
area or item revised
revision ID
window
number
P2BS1
S4B
P2B
L3
SD
EWIS
line of wall
line of wall
line of wall
G
CH
GRID REFERENCES
EXPRESSION OF LEVELS
Levels are shown in terms of Australian
Height Datum.
(AHD = 0)
All levels as per AS 110.301:1985
Reduced Level (plan view)
Existing Spot Level
New Spot Level
Finished Floor Level
For areas with carpet, vinyl, or
tiles, fixed directly to SL, and paint
finishes.
Structural Surface level.
For concrete work, SL includes all
concrete topping slabs and
levelling screeds.
Finished Ceiling Level
Reduced Level
(Section/Elevation view)
Existing External Ground
Level
New External Ground
Level
NORTH POINT
REFERENCE SYMBOLS
REVISION SYMBOLS
DRAWING ANNOTATION
DOORS AND WINDOWS
Refer to the floor plans and the Door and
Window Schedule for Door and Window
types, the rough opening sizes, finishes
and hardware.
1
DRAWING REFERENCE SYMBOLS
SECTION ELEVATION
DETAIL
(Reference to larger scale plan or detail)
Pendant LED
Downlight LED
Exhaust
Wall Lamp LED
LIGHTING
MECHANICAL
FIRE
Smoke Detector
Fire Sprinkler
EWIS Speaker
LEGENDS
Powerpoint & Light
Switch in wall
Hydronic Panel
HYDRAULIC
Core hole*
Gas connection
Hot & cold water supply
* GW - Greasy Waste
* TD - Tundish
* FW - Floor Waste
LED Strip light
NOTE:
1. D on symbol indicates dimmer
switch
2. X refers to nom height AFFL
3. All GPOs to be 10amp single phase
unless otherwise noted
All lamps to be warm white unless
otherwise noted
Electrical fitting colours:
W - White
B - Black
S - Stainless steel
All light circuits to be on separate
switches & dimmers and be connected
to 1 master switch on timer.
All GPOs to be on separate switch and
connected to master on timer.
Signage power supply to be on
separate switch and connected to
master on timer.
Powerpoint in wall
Light Switch in wall
ELECTRICAL
Note for Powerpoint Codes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel)
Note for Switch Codes:
S = Switch, 4 = Number of Switches, B =
Colour (ie: B for Black, W for White & T for
Stainless Steel)
Note for Powerpoint & SwitchCodes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel) S = Switch, 1 =
Number of Switches
Hose Cock
Spotlight LED
Floodlight LED
Sensor
ABBREVIATIONS BASED ON AS 1100:
AD Above Datum
Adj. Adjustable
Agg. Aggregate
Al. Aluminium
Alt. Alternate
AP Access Panel
APPR Approved
Approx. Approx
AS Australian Standard
B Bath
Bldg Building
BCA Building Code Australia
CAD Computer-Aided Drawing
CBI Coordinated Building Information
c/c Center to Center
CCTV Closed-Circuit Television
CHS Circular Hollow Section
CJ Construction Joint
Cnr. Corner
Code Building Code
COL. Column
CONC. Concrete
Corr. Corrugated
crs. Centers
DB Distribution Board
DH Double Hung
dia. Diameter
dim Dimension
DP Downpipe
DR Dry Riser
DW Dishwasher
dwg Drawing
EF Each Face
EW Each Way
EJ Expansion Joint
Ext External
Extg Existing
FA Fire Alarm
FAP Fire Alarm Panel
FCL Finished Ceiling Level
FE Fire Extinguisher
FF Fridge / Freezer
FFL Finished Floor Level
FG Fixed Glass
FH Fire Hydrant
FHR Fire Hose Reel
Fr. Freezer
FRR Fire Resistance Rating
FWG Floor Waste
GALV. Galvanised
GL Ground Level
GMS Galvanised Mild Steel
H Hosecock
HDG Hot Dipped Galvanised
horiz. Horizontal
horiz. Horizontal
ht height
HTR Heated Towel Rail
HWC Hot Water Cylinder
ID Internal Diameter
IJ Inspection Junction
Insul. Insulation
kg Kilogram
kW Kilowatt
max. Maximum
misc. Miscellaneous
m Metre
mm Millimetre
MS Mild Steel
MSB Main Switch Board
No. Number
Nom. Nominal
NTS Not To Scale
O/A Overall
O/H Overhead
OD Outside Diameter
OS Overall size
PFC Parallel Flange Channel
ply Plywood
PTN Partition
QTY Quantity
R Radius
rad. Radiator
Rad. Radiata
RC Reinforced Concrete
ref. Reference
reinf. Reinforcement
reqd. Required
RHS Rectangular Hollow Section
RL Reduced Level
RWH Rainwater Head
RWO Rainwater Outlet
RWS Rainwater Sump
S Sink
SC Sawcut Joint
SCHED Schedule
SL Structural Level
shwr. Shower
SHS Square Hollow Section
Sk Sketch
SP Soil Pipe
SPEC Specification
spr. Sprinkler
sqm Square Metre
SQ Square
SS Stainless Steel
SS. Soil Pipe / Sewer Pipe
SW. Stormwater Pipe
SWBD Switchboard
TA To Above
TB To Below
TBA To Be Advised
TBC To Be Confirmed
tub Laundry Tub
typ Typical
UB Universal Beam
UC Universal Column
U/G Underground
U/S Underside
Van U. Vanity Unit
vert. Vertical
W Watt
WC Water Closet (Toilet Pan)
WHB Wash Hand Basin
WM Washing Machine
NO.
001
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
2001
2002
2003
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
5001
5002
6001
TYPE
INFORMATION
PLANS
PLANS
PLANS
PLANS
PLANS
PLANS
PLANS
PLANS
PLANS
PLANS
PLANS
SECTIONS & ELEVATIONS
SECTIONS & ELEVATIONS
SECTIONS & ELEVATIONS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
INTERIOR DETAILS
DETAILS
DETAILS
DRAWN SCHEDULES
DRAWING
TRANSMITTAL, REVISIONS & IMAGES
DEMOLITION
PROPOSED SITE PLAN
GROUND FLOOR SETOUT
FIRST FLOOR SETOUT
GF GENERAL ARRANGEMENT
FF GENERAL ARRANGEMENT
SITE / ROOF
GF SERVICES & ELECTRICAL
FF SERVICES & ELECTRICAL
GF REFLECTED CEILING
FF REFLECTED CEILING
ELEVATIONS
ELEVATIONS
SECTIONS
KITCHEN / DINING
KITCHEN
KITCHEN
KITCHEN
KITCHEN
NOOK
LIVING
LIVING
LIVING
FF CIRCULATION
SECTIONS
SECTIONS
DOOR & WINDOW SCHEDULE
1011510
135155
10115
163
10115
WALL LINING
WALL LINING
SIP PANEL
BATTEN SPACING
WT1
EXTERNAL CLADDING - TYPE 1
INTERNAL LINING
WT3
SIP PANEL
BATTEN SPACING
WT2
EXTERNAL CLADDING - TYPE 2
INTERNAL LINING
BATTEN SPACING
VAPOR BARRIER
VAPOR BARRIER
SIP PANEL
DRAWING LIST
WALL TYPES
ABBREVIATIONS
2. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1001
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
DEMOLITION
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:200
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
CONCRETE DRIVEWAY
LIGHTPOLE
CONCRETE
PAVING
CAPPEDPICKET(1.2m)
PALING (1.68m)
PALING (1.63m)
No.287
470m„
13.4190°00'
35.05180°00'
13.41270°00'
35.050°00'
No.285
LOT5ONLP22727
SINGLESTOREY
WEATHERBOARD
DWELLING
GOOCHSTREET
CONCRETE
CROSSING
CONCRETE
CROSSING
CONCRETE
CROSSING
E-1
IN
V
52.90
IN
V
52.92
IN
V
52.91
IN
V
52.87
IN
V
52.75
IN
V
52.58BAC
K
53.04
BACKOFCONCRETEKERB
INVERTOFCONCRETEKERB
BACKOFCONCRETEKERB
INVERTOFCONCRETEKERB
G
UTTER
56.03
G
UTTER
56.60
G
UTTER
56.39
G
U
TTER
56.67
CH
IM
N
EY
TO
P
59.39
G
UTTER
56.71
G
UTTER
56.62
BAC
K
53.06
BAC
K
53.05
G
UTTER
56.51
G
U
TTER
55.92
G
UTTER
56.30
G
UTTER
56.51
G
UTTER
56.05
G
UTTER
55.80
G
UTTER
57.08
BA
CK
53.01
BAC
K
52.88
BAC
K
52.70
G
UTTER
56.08
W
ALL
TO
P
56.57
G
U
TTER
56.42
G
UTTER
55.72
G
UTTER
55.83
G
U
TTER
55.75
G
UTTER
56.62
G
UTTER
56.58
RID
G
E
58.84
RIDG
E
58.06
W
ALL
TO
P
56.55
W
A
LL
TO
P
55.58
R
IDG
E
59.24
W
ALL
TO
P
56.26
R
IDG
E
56.43
R
IDG
E
57.82
R
IDG
E
58.66
R
IDG
E
56.54
RID
G
E
58.67
RID
G
E
57.62
R
IDG
E
56.72
RID
G
E
56.55
R
IDG
E
56.64
PORCH
PORCH
PORCH
CUBBY
GALVANISED
IRONSHED
PERGOLA/PERGOLA
GALVANISED
IRONSHED
BRICKGARAGE
BRICKSTUDIO
SINGLESTOREY
WEATHERBOARD
DWELLING
No.283
SINGLESTOREY
WEATHERBOARD
DWELLING
No.328
SINGLESTOREY
WEATHERBOARD
DWELLING
PERGOLA
(ROSSMOYNEST)
FLR
LVL
54.04
FLR
LVL
53.98
53.0
53.0
53.5
53.5
53.5
53.44
53.43
53.40
53.37
53.42
53.36
53.35
53.43
53.51
53.59
53.56
53.68
53.64
53.65
53.69
53.12
53.28
53.48
53.47
53.51
53.49
53.54
53.54
53.35
53.52
53.56
53.62
53.68
53.66
53.56
53.67
53.49
53.51
53.48
53.50
53.47
53.44
53.60
53.69
GARDEN BED
SILL 54.88
TOP 55.88
TOP 55.99
SILL 54.83
TOP 55.41
SILL 54.47
TOP 55.54
SILL 53.30
SILL 55.39
TOP 56.36
TOP 56.28
SILL55.60
TOP56.21
TOP56.04
SILL55.00
SILL55.90
TOP56.38
TOP55.85
SILL55.04
SILL54.42
TOP55.86
SILL55.40
TOP55.97
WNHW
NHW
W
NHW
W
W
NHW
WW/DOOR
W/DOORW
6.10
1.09
3.07
6.12
1.21
6.14
1.40
PALING (1.63m)
PALING(1.65m)+
SCREEN(0.5m)
LAWN
SHADE
SAIL
PRIVATEOPENSPACE
PRIVATEOPENSPACE
PRIVATEOPENSPACE
LAWN
CONCRETE
PAVING
CONCRETE PATH
CONCRETEPAVEDPATIO
1
2
3
4
6
5
7
8
9
PALING (1.68m)
PICKET(1.36m)WOVENWIRE(0.63m)
NOT
FENCED
CONCRETEFOOTPATHCONCRETEFOOTPATH
TBMRIVET
RL=53.08AHD
CONCRETE DRIVEWAY
CONCRETE DRIVEWAY
1
1:200
PLAN DEMOLITION
3. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1002
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
PROPOSED SITE PLAN
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:200
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
UP
UP
UP
1030
15 010
12340
1810
4 255 3 635 5 030
105311810
1030
3 605
6 160
0.000 FL
53.700
COU R TYA RD
OU TDOOR D IN ING
SU NKE N COU R TY ARD
DE CK
BUILT-INSEAT
LAW N
FRON T L AWN
FOOTPATH
D EC K
SIDE PATH
DRI VEWA Y
285 GOOCH STREET
THORNBURY VIC 3071
PROPOSED 4 STOREY
BUILDING
ENTRY
GATE
FOOT PA TH
BUILT-INSEATBUILT-INSEAT
ADJACE NT D WE LLING
283 GO OC H STR EE T
ADJA CENT DWELLING
287 G OO CH S TRE ET
AD JA CE NT
DWE LLING
328
R O S S MO Y N
E STRE ET
CLOTHES LINE
PRODUCTIVE
GARDE N
RAIN WATER TANK S
10,000L CAPACITY
(Tankworks Modline)
GOOCHSTREET
ADJACE NT D WE LLING
283 GO OC H STR EE T
ADJA CENT DWELLING
287 G OO CH S TRE ET
AD JA CE NT
DWE LLING
328
R O S S MO Y N
E STRE ET
PA LING FENCE
PA LING FENCE
PALINGFENCE
1
1:200
PLAN SITE
4. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1003
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
GROUND FLOOR
SETOUT
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
UP
UP
UP
UP
UP
125 6 975 135 6 521 125
6 160 13 880 15 010
3 675 230 11 105
125550013547201351675125
104051251810
10301234040
125 3 880 135 1 025
135 50
135 8 320
125 4 005 125 3 635 135 4 780 125
960 4 255 3 635 5 030
83911351755125
12512091125
46951251550
1 340
135
3 560
53 700
53 400
53 400
53 400
53 400
53 680
53680
53 700
53 400
53 700
p a v i n g
1stflooro/h
P A L I N G F E N C E
P A L I N G F E N C E
D P
D P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
1:100
PLAN GROUND FLOOR SETOUT
5. N
1607
TENDER
PLANS
4 STOREY HOUSE
1004
Drawing Number Current Revision
Status
Job Number
FIRST FLOOR SETOUT
Scale at A3
1:100
A
J & E STOREY
Title
Client
Project
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
UP
125 4 205 135 2 455 135 1 665 135 1 275 135 3 460
135 4 370 135 4 545 135 3 460 135
1 000 12 880 1 600
1 400
135
2 720
6 160 15 480 2 305 11 105
350013512901351000
1575
135
4350
12530301352895125
125409563101840
1030105301850
1256060125
525163101850
52818260
125 13 630 125
6 160 13 880 3 910 11 105
56 900
56900
56900
56 70056 700
57 350
56 410
56 900
RO O F
BE LO W
RO O F
BELO W
A
W
N
IN
G
B
E
LO
W
PERGOLABELOW
CO URT YARD
BEL O W
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
1:100
PLAN FIRST FLOOR SETOUT
6. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1005
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
GF GENERAL
ARRANGEMENT
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
D17
D14D15
D18
W01
D02
W01
D13
D07
D08
D04
D03
D16
D10
D09
D12D11
D05
D06
D01
UP
UP
UP
UP
UP
700 1 175 1 100
4600
960 4 255 2 005 450 1 180 5 030
5 200 900 2 860 450 3 320 450 700
350500021602896125
110
900500300
8703313138410021101360450
1 699 900 960
9004600
265
760
710500600
1039910
1755
1
2003
1
2003
2
2003
2
2003
1
2001
2
2002
1
2002
2
2001
MF001
CEQ16
EQ021
CEQ12
EQ001
EQ006
CEQ17
EQ005
EQ002 EQ002
MF001
MF009
MF001
MF001
MF001
MF001
MF009
MF010MF010
MF010
MF010
CEQ22
EQ013
EQ018
EQ019
EQ020
BUILT-INSEATBUILT-INSEATBUILT-INSEAT
F r
0 . 0 0 0 F L
G A R A G E
F I L M R O O M
E N T R Y
KITCHEN
DINING
F r
butler's
pantry
pantry
L I V I N G
S T Y D Y
b u l k h e a d o / h
s e a t w / s t o r a g e
C O U R T Y A R D
p a v i n g
S U N K E N
C O U R T Y A R D
O U T D O O R
D I N I N G
1stflooro/h
D E C K
D E C K
workbench
storage
-0.300RL
- 0 . 3 0 0 R L
P A L I N G F E N C E
P A L I N G F E N C E
PALINGFENCE
D P
D P
CT
D W
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
WT03
WT03
WT01
WT02
WT01
WT01
WT02
WT01
WT02
WT02
WT01
WT01
WT03
WT03
WT03
WT01
WT03
ADJACENT DWELLING
283 GOOCH STREET
ADJACENT DWELLING
287 GOOCH STREET
RO SS M OY N
Notes
EQUIPMENT BY CLIENT
BBQ - Built-inCEQ12
Refer to Finishes & Fixtures Schedule
Dining Table - InsideCEQ16
Refer to Finishes & Fixtures Schedule
Dining Table - outsideCEQ17
Refer to Finishes & Fixtures Schedule
SofaCEQ22
Refer to Finishes & Fixtures Schedule
EQUIPMENT1 BY CONTRACTOR
Freestanding FireplaceEQ001
Refer to Finishes & Fixtures Schedule
Rainwater TankEQ002
Refer to Finishes & Fixtures Schedule
Basin - Wall outlet -1EQ005
Refer to Finishes & Fixtures Schedule
Toilet PanEQ006
Refer to Finishes & Fixtures Schedule
BasinEQ013
Refer to Finishes & Fixtures Schedule
In-Built CabinetsEQ018
Refer to Finishes & Fixtures Schedule
In-Built CabinetsEQ019
Refer to Finishes & Fixtures Schedule
In-Built CabinetsEQ020
Refer to Finishes & Fixtures Schedule
Island BenchEQ021
Refer to Finishes & Fixtures Schedule
MF MATERIALS & FINISHES
Concrete SlabMF001
Refer to Finishes & Fixtures Schedule.
Timber DeckingMF009
Refer to Finishes & Fixtures Schedule.
PavingMF010
Refer to Finishes & Fixtures Schedule.
1
1:100
PLAN GF GENERAL ARRANGEMENT
7. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1006
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
FF GENERAL
ARRANGEMENT
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
D20D20
D27 D27
D22D22
D26
UP
1
2003
1
2003
2
2003
2
2003
1
2001
2
2002
1
2002
2
2001
32902420475125
125240012602400125
697 800 1 935 800 1 910 800 1 085 450 720 955 1 150 650 3 530
9 116 400 1 774 400 3 791
9001525
435 900 900 900 435
10269001359002100
675900
1050
MF008
MF008
MF008
MF008
MF008
MF009
MF009
MF011
MF011
MF007
MF012
CEQ19
CEQ20
CEQ20
CEQ20
EQ006
EQ008
EQ007
EQ006
EQ012
EQ009
EQ010
EQ011
CEQ23
RO O F
BEL O W
RO O F
BELO W
A
W
N
IN
G
B
E
LO
W
PERGOLABELOW
+ 3 . 2 0 0 F L
ROBE
ROBEROBE
RO B E
CO URT YARD
BELO W
M A S T E R B E D
E N S U I T E
B E D 4
ROBE
B A T H
C I R C U L A T I O N
B E D 3
B E D 2
BALCONY
BALCONY
R O O F G A R D E N
p a v e r s
p a v e r s
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
D23D24
D25
D21D25
D25
D19D19
D28
D27
WT03
WT02
WT03
WT03
WT03
WT03
WT03
WT03
WT03
WT02
WT02
ADJACENT DWELLING
283 GOOCH STREET
ADJACENT DWELLING
287 GOOCH STREET
Notes
EQUIPMENT BY CLIENT
Bed - 1CEQ19
Refer to Finishes &
Fixtures Schedule
Bed - 2CEQ20
Refer to Finishes &
Fixtures Schedule
CouchCEQ23
Refer to Finishes &
Fixtures Schedule
EQUIPMENT1 BY
CONTRACTOR
Toilet PanEQ006
Refer to Finishes &
Fixtures Schedule
BathtubEQ007
Refer to Finishes &
Fixtures Schedule
Shower - Rail TypeEQ008
Refer to Finishes &
Fixtures Schedule
Shower - CabinEQ010
Refer to Finishes &
Fixtures Schedule
Basin - Wall outlet -2EQ011
Refer to Finishes &
Fixtures Schedule
Basin - Wall outlet -3EQ012
Refer to Finishes &
Fixtures Schedule
MF MATERIALS & FINISHES
Green RoofMF007
Refer to Finishes &
Fixtures Schedule.
Recycled TimberMF008
Refer to Finishes &
Fixtures Schedule.
Timber DeckingMF009
Refer to Finishes &
Fixtures Schedule.
Tile - 1MF011
Refer to Finishes &
Fixtures Schedule.
Polycarbonate /
Translucent Roofing
MF012
Refer to Finishes &
Fixtures Schedule
1
1:100
PLAN FF GENERAL ARRANGEMENT
8. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1007
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
SITE / ROOF
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
1
2003
1
2003
2
2003
2
2003
1
2001
2
2002
1
2002
2
2001
6 125 15 495 13 435
7 095 4 315 3 575 5 100 1 485 50 2 280 50 11 105
5186322032201785
16030027602760300160
99014040566440177510
5091335820
35
813
50
813
35
820
35
83850153250148350148350153550180050
105305808510
6 120 130 13 720 70 3 855 50 11 105
Pergola with
opportunity to install
sail shades and
retractabale awning.
MF012
MF007
MF013 MF013
Pergola with
opportunity to install
sail shades and
retractabale awning.
Pergola with
opportunity to install
sail shades and
retractabale awning
Rainwater Head + Downpipe
Rainwater Head + Downpipe
MF014
MF014
C O U R T Y A R D B E L O W
V O I D
V O I D
V O I D
V O I D
V O I D
A
W
N
IN
G
B
E
L
O
W
B O X G U T T E R m i n 1 : 1 0 0 F A L L
B O X G U T T E R m i n 1 : 1 0 0 F A L L
C O U R T Y A R D B E L O WC O U R T Y A R D B E L O W
FRONTLAWNBELOWDRIVEWAYBELOW
L A W N B E L O W
FALL30o
FLAT
FALL30o
FLAT
FLATFLAT
Notes
MF MATERIALS & FINISHES
Green RoofMF007
Refer to Finishes &
Fixtures Schedule.
Polycarbonate /
Translucent Roofing
MF012
Refer to Finishes &
Fixtures Schedule
Roofing MembraneMF013
Refer to Finishes &
Fixtures Schedule
Roof Sheeting -
Colorbond
MF014
Refer to Finishes &
Fixtures Schedule
1
1:100
PLAN SITE / ROOF
9. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1002
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
PROPOSED SITE PLAN
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:200
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
UP
UP
UP
1030
15 010
12340
1810
4 255 3 635 5 030
105311810
1030
3 605
6 160
0.000 FL
53.700
COU R TYA RD
OU TDOOR D IN ING
SU NKE N COU R TY ARD
DE CK
BUILT-INSEAT
LAW N
FRON T L AWN
FOOTPATH
D EC K
SIDE PATH
DRI VEWA Y
285 GOOCH STREET
THORNBURY VIC 3071
PROPOSED 4 STOREY
BUILDING
ENTRY
GATE
FOOT PA TH
BUILT-INSEATBUILT-INSEAT
ADJACE NT D WE LLING
283 GO OC H STR EE T
ADJA CENT DWELLING
287 G OO CH S TRE ET
AD JA CE NT
DWE LLING
328
R O S S MO Y N
E STRE ET
CLOTHES LINE
PRODUCTIVE
GARDE N
RAIN WATER TANK S
10,000L CAPACITY
(Tankworks Modline)
GOOCHSTREET
ADJACE NT D WE LLING
283 GO OC H STR EE T
ADJA CENT DWELLING
287 G OO CH S TRE ET
AD JA CE NT
DWE LLING
328
R O S S MO Y N
E STRE ET
PA LING FENCE
PA LING FENCE
PALINGFENCE
1
1:200
PLAN SITE
10. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1009
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
FF SERVICES &
ELECTRICAL
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
D20D20
D27 D27
D22D22
D26
UP
HC
P2W/1.2
2
P2W/1.2
2
P2W/0.3
2
P2W/0.3
2
P2W/0.3
2
P2W/0.3
2
P2W/0.3
2
P2W/0.3
2
P2W/0.3
2
WP/0.3
WP/0.3
WP/0.3
WP/0.3
Hydronic Heating -
Slab and Panels
D P
D P
S D
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
D23D24
D25
D21D25
D25
Ph+Data/0.3
P
Ph+Data/0.3
P
Ph+Data/0.3
P
Ph+Data/0.3
P
D19D19
D28
D27
4
P2BS1
S4B
P2B
line of wall
line of wall
line of wall
Powerpoint & Light
Switch in wall
Powerpoint in wall
Light Switch in wall
ELECTRICAL
Note for Powerpoint Codes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel)
Note for Switch Codes:
S = Switch, 4 = Number of Switches, B =
Colour (ie: B for Black, W for White & T for
Stainless Steel)
Note for Powerpoint & SwitchCodes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel) S = Switch, 1 =
Number of Switches
HC
Exhaust
MECHANICAL
Hydronic Panel
Hose Cock
G
CH
HYDRAULIC
Core hole*
Gas connection
Hot & cold water supply
* GW - Greasy Waste
* TD - Tundish
* FW - Floor Waste
NOTE:
1. D on symbol indicates dimmer
switch
2. X refers to nom height AFFL
3. All GPOs to be 10amp single phase
unless otherwise noted
All lamps to be warm white unless
otherwise noted
Electrical fitting colours:
W - White
B - Black
S - Stainless steel
All light circuits to be on separate
switches & dimmers and be connected
to 1 master switch on timer.
1
1:100
PLAN FF SERVICES & ELECTRICAL
11. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1010
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
GF REFLECTED
CEILING
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
S1W/1.2
S3W/1.2
3
S1W/1.2
S2/1.2
2
S1W/0.75
S1W/1.2
S2/1.2 2
S1W/1.2
S2/1.2
2
S3W/1.2
3
S1W/1.2S1W/1.2
S2/1.2
2
S2/1.2
2
S1W/1.2
S3W/1.2
3
L2 L2
L2 L2
L2 L2
L2 L2
L2 L2
L2
L2
L2
L2
L2L2
L2L2
L4 L4
L2
L2
L4
L2
L2
L2
L2
L2
L2
L4
L4
L1
L1
L1
L4 L4
L4
L4
L4L4
L4
L6
L6
L6
L6
L4
1
2003
1
2003
2
2003
2
2003
1
2001
2
2002
1
2002
2
2001
MF012
EQ016
EQ017
EQ016
EQ017
EQ016
EQ016
EQ016
MF015
MF015
MF015
MF015
MF015
MF015
FAN
FAN
EQ017
L 7
L 3
L 3
b u l k h e a d l i n e
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
4
L4
L1
L2
L5
L6
P2BS1
S4B
P2B
L3
line of wall
line of wall
line of wall
Pendant LED
Downlight LED
Wall Lamp LED
LIGHTING
Powerpoint & Light
Switch in wall
LED Strip light
Powerpoint in wall
Light Switch in wall
ELECTRICAL
Note for Powerpoint Codes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel)
Note for Switch Codes:
S = Switch, 4 = Number of Switches, B =
Colour (ie: B for Black, W for White & T for
Stainless Steel)
Note for Powerpoint & SwitchCodes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel) S = Switch, 1 =
Number of Switches
Spotlight LED
Floodlight LED
Sensor
HC
Exhaust
MECHANICAL
FIRE
Hydronic Panel
Hose Cock
Notes
EQUIPMENT1 BY
CONTRACTOR
Roller BlindEQ016
Refer to Finishes &
Fixtures Schedule
Vertical BlindEQ017
Refer to Finishes &
Fixtures Schedule
LIGHTING
Ceiling FanFAN
Fan to centrally
suspended in specific
room. Refer to Finishes
& Fixtures Schedule
LED PendantL1
Suspended Pendant
Light. Ceiling Rose
mounted to wall - note
location on drawings.
All lamps to be warm
white 2700K unless
otherwise noted - allow
adequate flex for drop
adjustment - to be
discussed with
Architect/Designer.
Refer to Finishes &
Fixtures Schedule.
LED Down LightL2
Ceiling Surface
Mounted. All
transformers to be
concealed. All lamps to
be warm white 2700K
unless otherwise noted.
Refer to Finishes &
Fixtures Schedule
LED Strip LightL3
Joinery Recess
Mounted. All
transformers to be
concealed. All lamps to
be warm white 2700K
unless otherwise noted.
Refer to Finishes &
Fixtures Schedule
LED Wall LightL4
Wall Mounted 1800mm
FFL to underside of
fitting unless otherwise
noted. All transformers
to be concealed, All
lamps to be warm white
2700K unless
otherwise noted. Refer
to Finishes & Fixtures
Schedule
LED Flood LightL6
Wall Mounted 2400mm
FFL to underside of
fitting unless otherwise
noted. All transformers
to be concealed, All
lamps to be warm white
2700K unless
otherwise noted. Refer
to Finishes & Fixtures
Schedule
LED Custom LightL7
LED Strip light built into
RHS. Allow for install
only. Discuss with
Architect/Designer prior
to installation
MF MATERIALS & FINISHES
Polycarbonate /
Translucent Roofing
MF012
Refer to Finishes &
Fixtures Schedule
PlasterboardMF015
Refer to Finishes &
Fixtures Schedule
1
1:100
PLAN GF REFLECTED CEILING
12. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1011
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
FF REFLECTED
CEILING
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
S1W/1.2
S3W/1.2
3
S1W/1.2
S1W/1.2
S2/1.2
2
S2/1.2
2S2/1.22
S1W/1.2
S1W/1.2
S1W/1.2
S1W/1.2
S1W/1.2
S1W/1.2
S1W/1.2S1W/1.2
L1
L4
L1
L4
L4
L1
L4
L4
L4
L4
L4
L1L1
L4
L1
L4
L4
L1
L4
L4
L1
L1
L4
L4L4 L4 L4
L4
1
2003
1
2003
2
2003
2
2003
1
2001
2
2002
1
2002
2
2001
MF004
FAN
MF004
MF004
MF004
MF004
EQ017
EQ016
EQ017
EQ016
EQ016
EQ016
EQ017
EQ016
L 3
RAKINGUP
RAKINGUP
RAKINGUP
RAKINGUP
RAKINGUP
RAKINGUP
L3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
4
L4
L1
L2
L5
L6
P2BS1
S4B
P2B
L3
line of wall
line of wall
line of wall
Pendant LED
Downlight LED
Wall Lamp LED
LIGHTING
Powerpoint & Light
Switch in wall
LED Strip light
Powerpoint in wall
Light Switch in wall
ELECTRICAL
Note for Powerpoint Codes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel)
Note for Switch Codes:
S = Switch, 4 = Number of Switches, B =
Colour (ie: B for Black, W for White & T for
Stainless Steel)
Note for Powerpoint & SwitchCodes:
P = Powerpoint, 2 = Number of Gangs, B
= Colour (ie: B for Black, W for White & T
for Stainless Steel) S = Switch, 1 =
Number of Switches
Spotlight LED
Floodlight LED
Sensor
HC
Exhaust
MECHANICAL
FIRE
Hydronic Panel
Hose Cock
Notes
EQUIPMENT1 BY
CONTRACTOR
Roller BlindEQ016
Refer to Finishes &
Fixtures Schedule
Vertical BlindEQ017
Refer to Finishes &
Fixtures Schedule
LIGHTING
Ceiling FanFAN
Fan to centrally
suspended in specific
room. Refer to Finishes
& Fixtures Schedule
LED PendantL1
Suspended Pendant
Light. Ceiling Rose
mounted to wall - note
location on drawings.
All lamps to be warm
white 2700K unless
otherwise noted - allow
adequate flex for drop
adjustment - to be
discussed with
Architect/Designer.
Refer to Finishes &
Fixtures Schedule.
LED Strip LightL3
Joinery Recess
Mounted. All
transformers to be
concealed. All lamps to
be warm white 2700K
unless otherwise noted.
Refer to Finishes &
Fixtures Schedule
LED Wall LightL4
Wall Mounted 1800mm
FFL to underside of
fitting unless otherwise
noted. All transformers
to be concealed, All
lamps to be warm white
2700K unless
otherwise noted. Refer
to Finishes & Fixtures
Schedule
MF MATERIALS & FINISHES
PlywoodMF004
Refer to Finishes &
Fixtures Schedule.
1
1:100
PLAN FF REFLECTED CEILING
13. 1607
SECTIONS &
ELEVATIONS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
2001
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
ELEVATIONS
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
GROUND
RL 53,700
FIRST
RL 56,900
ROOF
RL 59,300
TOP
RL 61,430
GROUND
RL 53,700
FIRST
RL 56,900
ROOF
RL 59,300
TOP
RL 61,430
1000
Min.
MF003MF002 MF017
L4L4 L4
WP POWER
L4
Pergola at rear North side
MF005MF005MF017
CEQ12
L4
DOWNPIPE
MF019
D18
D28
D02W01 D01
RESCODE54.04-1
SITEBOUNDARY
RESCODE
54.04-1
SITEBOUNDARY
GROUND
RL 53,700
FIRST
RL 56,900
ROOF
RL 59,300
TOP
RL 61,430
GROUND
RL 53,700
FIRST
RL 56,900
ROOF
RL 59,300
TOP
RL 61,430
2705100
1000
MF003MF017 MF005
L4
WP POWER
DECORATIVE WALL LATTICE
MF018
L4
L6 L6 L6
L4
L4
CEQ12
PERGOLA STRUCTURE
MF005
CEQ17
MF003
MF002
MF017
MF002
D20
D20
D11D12D13
W03
W02
RESCODE54.04-1
SITEBOUNDARY
RESCODE
54.04-1
SITEBOUNDARY
Notes
EQUIPMENT BY CLIENT
BBQ - Built-inCEQ12
Refer to Finishes & Fixtures Schedule
Dining Table - outsideCEQ17
Refer to Finishes & Fixtures Schedule
LIGHTING
LED Wall LightL4
Wall Mounted 1700mm FFL to underside
of fitting unless otherwise noted. All
transformers to be concealed, All lamps to
be warm white 2700K unless otherwise
noted. Refer to Finishes & Fixtures
Schedule
LED Flood LightL6
Wall Mounted 2400mm FFL to underside
of fitting unless otherwise noted. All
transformers to be concealed, All lamps to
be warm white 2700K unless otherwise
noted. Refer to Finishes & Fixtures
Schedule
MF MATERIALS & FINISHES
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
Timber CladdingMF003
Refer to Finishes & Fixtures Schedule
Mild SteelMF005
Refer to Finishes & Fixtures Schedule.
Polycarbonate / Translucent RoofingMF012
Refer to Finishes & Fixtures Schedule
Roof Sheeting - ColorbondMF014
Refer to Finishes & Fixtures Schedule
Tiled Wall CladdingMF017
Refer to Finishes & Fixtures Schedule
Metal Perforated MeshMF018
Refer to Finishes & Fixtures Schedule
Powdercoat - Dark GreyMF019
Refer to Finishes & Fixtures Schedule
1
1:100
ELEVATION SOUTH
2
1:100
ELEVATION NORTH
14. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1003
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
GROUND FLOOR
SETOUT
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
UP
UP
UP
UP
UP
125 6 975 135 6 521 125
6 160 13 880 15 010
3 675 230 11 105
125550013547201351675125
104051251810
10301234040
125 3 880 135 1 025
135 50
135 8 320
125 4 005 125 3 635 135 4 780 125
960 4 255 3 635 5 030
83911351755125
12512091125
46951251550
1 340
135
3 560
53 700
53 400
53 400
53 400
53 400
53 680
53680
53 700
53 400
53 700
p a v i n g
1stflooro/h
P A L I N G F E N C E
P A L I N G F E N C E
D P
D P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
1:100
PLAN GROUND FLOOR SETOUT
15. 1607
SECTIONS &
ELEVATIONS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
2003
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
SECTIONS
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
GROUND
RL 53,700
FIRST
RL 56,900
ROOF
RL 59,300
TOP
RL 61,430
ROOF
RL 59,300
TOP
RL 61,430
FIRST
RL 56,900
GROUND
RL 53,700
MF002MF014
D10
D23 D27D27 D25
D05
MASTER BEDCIRCULATION
LIVING
BED 2BALCONY
BALCONY
DECK
FILM ROOM
DECK
2
5001
1
5001
GROUND
RL 53,700
FIRST
RL 56,900
ROOF
RL 59,300
TOP
RL 61,430
TOP
RL 61,430
ROOF
RL 59,300
GROUND
RL 53,700
FIRST
RL 56,900
2
5002
3
5002
1
5002
MF002
MF002
W01
D27
D16
D06
SITEBOUNDARY
RESCODE
54.04-1
SITEBOUNDARY
CIRCULATION
FALL 30
o FALL 30 o
ENTRY GARAGE
MASTER BED BED 4
Notes
MF MATERIALS & FINISHES
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
Roof Sheeting - ColorbondMF014
Refer to Finishes & Fixtures Schedule
1
SECTION A-A
2
SECTION B-B
16. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3001
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
KITCHEN / DINING
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:40
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
4
3
1
2
EQ021
EQ003
EQ004
CEQ15
CEQ14
CEQ24
CEQ13
CEQ25
butler'spantrypantry
F r
CT
DW
Notes
EQUIPMENT BY CLIENT
RefrigeratorCEQ13
Refer to Finishes & Fixtures Schedule
CooktopCEQ14
Refer to Finishes & Fixtures Schedule
DishwasherCEQ15
Refer to Finishes & Fixtures Schedule
OvenCEQ24
Refer to Finishes & Fixtures Schedule
CabinetsCEQ25
Refer to Finishes & Fixtures Schedule
EQUIPMENT1 BY CONTRACTOR
Sink - Double BowlEQ003
Refer to Finishes & Fixtures Schedule
Sink MixerEQ004
Refer to Finishes & Fixtures Schedule
Island BenchEQ021
Refer to Finishes & Fixtures Schedule
1:40
PLAN KEY - KITCHEN
17. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3002
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
KITCHEN
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
9007001400
2 570 1 000 310 790 1 075
3000
5 720
489 514 514 514 514
600
L1
DR
L7
CEQ14
EQ021
CEQ25
L4 L4
DR DR
DR
EQ022
DR
MF002
MF006
MF001
MF004
MF004
MF002
L2L2
EQ004D14
D15
SEATING / CABINETS TOP
FL 53,850
LOWERED FLOOR
FL 53,400
RANGE HOOD
FL 55,000
Notes
ABBREVIATIONS1 : JOINERY
DrawerDR
Drawer Construction: Nominally 16mm
thick material to sides and base, screwed
together. Contractor to confirm
appropriateness based on substrate
selection prior to manufacture.
EQUIPMENT BY CLIENT
CooktopCEQ14
Refer to Finishes & Fixtures Schedule
CabinetsCEQ25
Refer to Finishes & Fixtures Schedule
EQUIPMENT1 BY CONTRACTOR
Sink MixerEQ004
Refer to Finishes & Fixtures Schedule
Island BenchEQ021
Refer to Finishes & Fixtures Schedule
Range HoodEQ022
Refer to Finishes & Fixtures Schedule
LIGHTING
LED PendantL1
Suspended Pendant Light. Ceiling Rose
mounted to wall - note location on
drawings. All lamps to be warm white
2700K unless otherwise noted - allow
adequate flex for drop adjustment - to be
discussed with Architect/Designer. Refer to
Finishes & Fixtures Schedule.
LED Down LightL2
Ceiling Surface Mounted. All transformers
to be concealed. All lamps to be warm
white 2700K unless otherwise noted. Refer
to Finishes & Fixtures Schedule
LED Wall LightL4
Wall Mounted 1700mm FFL to underside
of fitting unless otherwise noted. All
transformers to be concealed, All lamps to
be warm white 2700K unless otherwise
noted. Refer to Finishes & Fixtures
Schedule
LED Custom LightL7
LED Strip light built into RHS. Allow for
install only. Discuss with
Architect/Designer prior to installation
MF MATERIALS & FINISHES
ConcreteMF001
Refer to Finishes & Fixtures Schedule.
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
PlywoodMF004
Refer to Finishes & Fixtures Schedule.
1
1:20
ELEVATION KITCHEN
18. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3003
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
KITCHEN
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
50 1 300 3 200 50
4 600 320 555
9007001400
4502550
3000
900
550 1 580
L1
L7
CEQ15
L4
DR
EQ022
MF002
MF006
L2
L2
CB
AS
KB
CEQ24
CEQ14
EQ003
EQ004
MF021
EQ021
CEQ25
MF021
DR
DR
DR
KB
MF004
MF001
LOWERED FLOOR
FL 53,400
RANGE HOOD
FL 55,000
Notes
ABBREVIATIONS1 : JOINERY
Adjustable ShelfAS
Shelf thickness nominally: Up to 900mm
length 18mm thick up to 1200mm long
25mm thick Adjustable shelf supports:
5mm diameter holes at 32mm spacings.
Enclosed shelves use clear plastic shelf
supports with metal pins. Open shelves
use nickel library studs and ferrules at
50mm c/c.
CupboardCB
Hinges: Provide concealed all metal
hinges with the following features:
adjustable for height, side and depth
location of door self- closing action hold
open function nickel-plated. 170A°
opening, unless adjacent to return wall,
where they are to be 90A° opening
DrawerDR
Drawer Construction: Nominally 16mm
thick material to sides and base, screwed
together. Contractor to confirm
appropriateness based on substrate
selection prior to manufacture.
EQUIPMENT BY CLIENT
CooktopCEQ14
Refer to Finishes & Fixtures Schedule
DishwasherCEQ15
Refer to Finishes & Fixtures Schedule
CabinetsCEQ25
Refer to Finishes & Fixtures Schedule
EQUIPMENT1 BY CONTRACTOR
Sink - Double BowlEQ003
Refer to Finishes & Fixtures Schedule
Sink MixerEQ004
Refer to Finishes & Fixtures Schedule
Island BenchEQ021
Refer to Finishes & Fixtures Schedule
Range HoodEQ022
Refer to Finishes & Fixtures Schedule
LIGHTING
LED PendantL1
Suspended Pendant Light. Ceiling Rose
mounted to wall - note location on
drawings. All lamps to be warm white
2700K unless otherwise noted - allow
adequate flex for drop adjustment - to be
discussed with Architect/Designer. Refer to
Finishes & Fixtures Schedule.
LED Down LightL2
Ceiling Surface Mounted. All transformers
to be concealed. All lamps to be warm
white 2700K unless otherwise noted. Refer
to Finishes & Fixtures Schedule
LED Wall LightL4
Wall Mounted 1700mm FFL to underside
of fitting unless otherwise noted. All
transformers to be concealed, All lamps to
be warm white 2700K unless otherwise
noted. Refer to Finishes & Fixtures
Schedule
LED Custom LightL7
LED Strip light built into RHS. Allow for
install only. Discuss with
Architect/Designer prior to installation
MF MATERIALS & FINISHES
ConcreteMF001
Refer to Finishes & Fixtures Schedule.
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
PlywoodMF004
Refer to Finishes & Fixtures Schedule.
PlasterboardMF006
Refer to Finishes & Fixtures Schedule.
Laminate - 1MF021
Refer to Finishes & Fixtures Schedule
2
1:20
ELEVATION KITCHEN
19. N
1607
TENDER
PLANS
4 STOREY HOUSE
1004
Drawing Number Current Revision
Status
Job Number
FIRST FLOOR SETOUT
Scale at A3
1:100
A
J & E STOREY
Title
Client
Project
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
UP
125 4 205 135 2 455 135 1 665 135 1 275 135 3 460
135 4 370 135 4 545 135 3 460 135
1 000 12 880 1 600
1 400
135
2 720
6 160 15 480 2 305 11 105
350013512901351000
1575
135
4350
12530301352895125
125409563101840
1030105301850
1256060125
525163101850
52818260
125 13 630 125
6 160 13 880 3 910 11 105
56 900
56900
56900
56 70056 700
57 350
56 410
56 900
RO O F
BE LO W
RO O F
BELO W
A
W
N
IN
G
B
E
LO
W
PERGOLABELOW
CO URT YARD
BEL O W
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
1
1:100
PLAN FIRST FLOOR SETOUT
20. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3005
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
KITCHEN
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
457 457 457 457 457 760 388 388 388 388
4 600
50 3 200 1 300 50
885 4 600
85050
9002100
3000
L7
CB
MF002
MF006
L1
L4
MF021
MF001 EQ004
CB CB CB CB
AS
AS
AS
AS AS
AS
AS
AS
AS
AS
AS
AS
AS AS
AS
AS
AS
AS
MF004
MF004 AS
CB
CEQ13
CEQ14
EQ022
D16
LOWERED FLOOR
Notes
ABBREVIATIONS1 : JOINERY
Adjustable ShelfAS
Shelf thickness nominally: Up to 900mm
length 18mm thick up to 1200mm long
25mm thick Adjustable shelf supports:
5mm diameter holes at 32mm spacings.
Enclosed shelves use clear plastic shelf
supports with metal pins. Open shelves
use nickel library studs and ferrules at
50mm c/c.
CupboardCB
Hinges: Provide concealed all metal
hinges with the following features:
adjustable for height, side and depth
location of door self- closing action hold
open function nickel-plated. 170A°
opening, unless adjacent to return wall,
where they are to be 90A° opening
EQUIPMENT BY CLIENT
RefrigeratorCEQ13
Refer to Finishes & Fixtures Schedule
CooktopCEQ14
Refer to Finishes & Fixtures Schedule
EQUIPMENT1 BY CONTRACTOR
Sink MixerEQ004
Refer to Finishes & Fixtures Schedule
Range HoodEQ022
Refer to Finishes & Fixtures Schedule
LIGHTING
LED PendantL1
Suspended Pendant Light. Ceiling Rose
mounted to wall - note location on
drawings. All lamps to be warm white
2700K unless otherwise noted - allow
adequate flex for drop adjustment - to be
discussed with Architect/Designer. Refer to
Finishes & Fixtures Schedule.
LED Wall LightL4
Wall Mounted 1700mm FFL to underside
of fitting unless otherwise noted. All
transformers to be concealed, All lamps to
be warm white 2700K unless otherwise
noted. Refer to Finishes & Fixtures
Schedule
LED Custom LightL7
LED Strip light built into RHS. Allow for
install only. Discuss with
Architect/Designer prior to installation
MF MATERIALS & FINISHES
ConcreteMF001
Refer to Finishes & Fixtures Schedule.
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
PlywoodMF004
Refer to Finishes & Fixtures Schedule.
PlasterboardMF006
Refer to Finishes & Fixtures Schedule.
Laminate - 1MF021
Refer to Finishes & Fixtures Schedule
4
1:20
ELEVATION KITCHEN
21. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3006
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
NOOK
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:40, 1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
UP
5
6
1 2 3 4 5 6 7 8 9 10 11
43020330203302033020330203302033020250200
115 515 20 939 20 785
1 070 20 618 20 551
698 20 1 157 20 383
1 084 20
310 20 451 20
2 279
3000
L2
L3
MF004
MF002
MF002
MF004
MF004
OS
DR DR DR DR
OS
OS
OS
OS
OS
D07
Stairs
bottom
surface
Seating
LOWERED CEILING
FL 56,200
SEATING
FL 53,850
465 290 1 134
50 1 375
43020330203302033020330203302033020250
2800
2 025
Stairs bottom surface
L3
MF004
MF006
OS
OS
OS
OS
OS
OS
L2
D06
SEATING
FL 53,850
LOWERED CEILING
FL 56,200
Notes
ABBREVIATIONS1 : JOINERY
DrawerDR
Drawer Construction: Nominally 16mm
thick material to sides and base, screwed
together. Contractor to confirm
appropriateness based on substrate
selection prior to manufacture.
Open ShelfOS
Exposed edge DAR, unless otherwise
noted on drawings. Finish to be free from
imperfections such as dust marks, sanding
marks and 'orange peel' effect.
LIGHTING
LED Down LightL2
Ceiling Surface Mounted. All transformers
to be concealed. All lamps to be warm
white 2700K unless otherwise noted. Refer
to Finishes & Fixtures Schedule
LED Strip LightL3
Joinery Recess Mounted. All transformers
to be concealed. All lamps to be warm
white 2700K unless otherwise noted. Refer
to Finishes & Fixtures Schedule
MF MATERIALS & FINISHES
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
PlywoodMF004
Refer to Finishes & Fixtures Schedule.
PlasterboardMF006
Refer to Finishes & Fixtures Schedule.
1:40
PLAN KEY - NOOK
5
1:20
ELEVATION NOOK
6
1:20
ELEVATION NOOK
22. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3007
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
LIVING
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:40, 1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
D09
7
9
8
EQ001
MF023
16 17
300 875 3 132 500
544 519 519 519 519 494 519
430201180203002033020
4301200690480
1 175 3 632
20 892 20 555 20 1 005 20 1 080 20
20 1 192 20 780 20 1 580 20
2800
L3
MF002
MF004
MF004
MF002
MF002
MF004
EQ001
TV
OS
OS OS
OS
OS
OS
DR DR DR DR DR DR
L4
LOWERED FLOOR
FL 53,400
SEATING / CABINETS TOP
FL 53,850
LOWERED CEILING
FL 56,200
FIREPLACE PODIUM
FL 53,500
TOP SHELVES
FL 55,030
Notes
ABBREVIATIONS1 : JOINERY
DrawerDR
Drawer Construction: Nominally 16mm
thick material to sides and base, screwed
together. Contractor to confirm
appropriateness based on substrate
selection prior to manufacture.
Open ShelfOS
Exposed edge DAR, unless otherwise
noted on drawings. Finish to be free from
imperfections such as dust marks, sanding
marks and 'orange peel' effect.
EQUIPMENT1 BY CONTRACTOR
Freestanding FireplaceEQ001
Refer to Finishes & Fixtures Schedule
LIGHTING
LED Strip LightL3
Joinery Recess Mounted. All transformers
to be concealed. All lamps to be warm
white 2700K unless otherwise noted. Refer
to Finishes & Fixtures Schedule
LED Wall LightL4
Wall Mounted 1700mm FFL to underside
of fitting unless otherwise noted. All
transformers to be concealed, All lamps to
be warm white 2700K unless otherwise
noted. Refer to Finishes & Fixtures
Schedule
MF MATERIALS & FINISHES
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
PlywoodMF004
Refer to Finishes & Fixtures Schedule.
CarpetMF023
Refer to Finishes & Fixtures Schedule
1:40
ELEVATION KEY - LIVING
7
1:20
ELEVATION LIVING
23. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3008
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
LIVING
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
430201180203002033020480
500 325
525 300
2800
MF004
L3
TV
EQ001
OS
DR
OS
MF002
MF004
D08
D09
LOWERED FLOOR
FL 53,400
SEATING / CABINETS TOP
FL 53,850
LOWERED CEILING
FL 56,200
TOP SHELVES
FL 55,075
Notes
ABBREVIATIONS1 : JOINERY
DrawerDR
Drawer Construction: Nominally 16mm
thick material to sides and base, screwed
together. Contractor to confirm
appropriateness based on substrate
selection prior to manufacture.
Open ShelfOS
Exposed edge DAR, unless otherwise
noted on drawings. Finish to be free from
imperfections such as dust marks, sanding
marks and 'orange peel' effect.
EQUIPMENT1 BY CONTRACTOR
Freestanding FireplaceEQ001
Refer to Finishes & Fixtures Schedule
LIGHTING
LED Strip LightL3
Joinery Recess Mounted. All transformers
to be concealed. All lamps to be warm
white 2700K unless otherwise noted. Refer
to Finishes & Fixtures Schedule
MF MATERIALS & FINISHES
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
PlywoodMF004
Refer to Finishes & Fixtures Schedule.
8
1:20
ELEVATION LIVING
24. N
1607
PLANS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
1005
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
GF GENERAL
ARRANGEMENT
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:100
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
D17
D14D15
D18
W01
D02
W01
D13
D07
D08
D04
D03
D16
D10
D09
D12D11
D05
D06
D01
UP
UP
UP
UP
UP
700 1 175 1 100
4600
960 4 255 2 005 450 1 180 5 030
5 200 900 2 860 450 3 320 450 700
350500021602896125
110
900500300
8703313138410021101360450
1 699 900 960
9004600
265
760
710500600
1039910
1755
1
2003
1
2003
2
2003
2
2003
1
2001
2
2002
1
2002
2
2001
MF001
CEQ16
EQ021
CEQ12
EQ001
EQ006
CEQ17
EQ005
EQ002 EQ002
MF001
MF009
MF001
MF001
MF001
MF001
MF009
MF010MF010
MF010
MF010
CEQ22
EQ013
EQ018
EQ019
EQ020
BUILT-INSEATBUILT-INSEATBUILT-INSEAT
F r
0 . 0 0 0 F L
G A R A G E
F I L M R O O M
E N T R Y
KITCHEN
DINING
F r
butler's
pantry
pantry
L I V I N G
S T Y D Y
b u l k h e a d o / h
s e a t w / s t o r a g e
C O U R T Y A R D
p a v i n g
S U N K E N
C O U R T Y A R D
O U T D O O R
D I N I N G
1stflooro/h
D E C K
D E C K
workbench
storage
-0.300RL
- 0 . 3 0 0 R L
P A L I N G F E N C E
P A L I N G F E N C E
PALINGFENCE
D P
D P
CT
D W
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
WT03
WT03
WT01
WT02
WT01
WT01
WT02
WT01
WT02
WT02
WT01
WT01
WT03
WT03
WT03
WT01
WT03
ADJACENT DWELLING
283 GOOCH STREET
ADJACENT DWELLING
287 GOOCH STREET
RO SS M OY N
Notes
EQUIPMENT BY CLIENT
BBQ - Built-inCEQ12
Refer to Finishes & Fixtures Schedule
Dining Table - InsideCEQ16
Refer to Finishes & Fixtures Schedule
Dining Table - outsideCEQ17
Refer to Finishes & Fixtures Schedule
SofaCEQ22
Refer to Finishes & Fixtures Schedule
EQUIPMENT1 BY CONTRACTOR
Freestanding FireplaceEQ001
Refer to Finishes & Fixtures Schedule
Rainwater TankEQ002
Refer to Finishes & Fixtures Schedule
Basin - Wall outlet -1EQ005
Refer to Finishes & Fixtures Schedule
Toilet PanEQ006
Refer to Finishes & Fixtures Schedule
BasinEQ013
Refer to Finishes & Fixtures Schedule
In-Built CabinetsEQ018
Refer to Finishes & Fixtures Schedule
In-Built CabinetsEQ019
Refer to Finishes & Fixtures Schedule
In-Built CabinetsEQ020
Refer to Finishes & Fixtures Schedule
Island BenchEQ021
Refer to Finishes & Fixtures Schedule
MF MATERIALS & FINISHES
Concrete SlabMF001
Refer to Finishes & Fixtures Schedule.
Timber DeckingMF009
Refer to Finishes & Fixtures Schedule.
PavingMF010
Refer to Finishes & Fixtures Schedule.
1
1:100
PLAN GF GENERAL ARRANGEMENT
25. 1607
INTERIOR DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
3010
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
FF CIRCULATION
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:40, 1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
11253001000
2 335 540 685 985
10
J O I N E R Y / F E N C I N G - O P E N S H E L V E S
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
20 437 20 447 20 447 20 447 20 437 20 560 646 20
2 335 560 665 985
20307203072030720
1000
L4
MF002
DR
L4
L1
MF004
MF004 MF004
OS OS OS OS OS OS
OSOSOS OS OS OS
OSOSOS OS OS OS
D19
FIRST FLOOR
FL 56,900
JOINERY TOP
FL 57,900
Notes
ABBREVIATIONS1 : JOINERY
Open ShelfOS
Exposed edge DAR, unless otherwise
noted on drawings. Finish to be free from
imperfections such as dust marks, sanding
marks and 'orange peel' effect.
LIGHTING
LED PendantL1
Suspended Pendant Light. Ceiling Rose
mounted to wall - note location on
drawings. All lamps to be warm white
2700K unless otherwise noted - allow
adequate flex for drop adjustment - to be
discussed with Architect/Designer. Refer to
Finishes & Fixtures Schedule.
LED Wall LightL4
Wall Mounted 1700mm FFL to underside
of fitting unless otherwise noted. All
transformers to be concealed, All lamps to
be warm white 2700K unless otherwise
noted. Refer to Finishes & Fixtures
Schedule
MF MATERIALS & FINISHES
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
PlywoodMF004
Refer to Finishes & Fixtures Schedule.
1:40
ELEVATION KEY - FF CIRCULATION
10
1:20
ELEVATION FF CIRCULATION
26. 1607
DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
5001
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
SECTIONS
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:20
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
1905
505
1000
10mm PLASTERBOARD CEILING
RECYCLED TIMBER FLOORING
FIRST FLOOR
MF008
D01
CONCRETE SLAB
GROUND FLOOR
MF001
FOOTING TO
ENGINEER
DETAIL
115mm STRUCTURAL
INSULATED PANEL
10mm PLASTERBOARD
MF002
10mm PLASTERBOARD
MF002
VAPOUR BARRIER
BALCONY FENCING
1000mm min HEIGHT FROM FFL
MF005
TIMBER DECK
MF009
MOISTURE
INSULATION
115mm STRUCTURAL
INSULATED PANEL
10mm PLASTERBOARD
MF002
10mm PLASTERBOARD CEILING
CONCRETE SLAB
GROUND FLOOR
MF001
RECYCLED TIMBER FLOORING
FIRST FLOOR
MF008
10mm PLASTERBOARD
MF002
IN-BUILT CABINETS
EQ018
FOOTING TO ENGINEER
DETAIL
Notes
EQUIPMENT1 BY CONTRACTOR
In-Built CabinetsEQ018
Refer to Finishes & Fixtures Schedule
MF MATERIALS & FINISHES
Concrete SlabMF001
Refer to Finishes & Fixtures Schedule.
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
Mild SteelMF005
Refer to Finishes & Fixtures Schedule.
Recycled TimberMF008
Refer to Finishes & Fixtures Schedule.
Timber DeckingMF009
Refer to Finishes & Fixtures Schedule.
1
1:20
DETAIL WALL SECTION 1
2
1:20
DETAIL WALL SECTION 2
27. 1607
DETAILS
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
5002
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
SECTIONS
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:20, 1:10
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
180
115mm STRUCTURAL
INSULATED PANEL
10mm PLASTERBOARD
MF002
VAPOUR BARRIER SARKING
TIMBER BATTEN TO FORM
A VENTILATED CAVITY
TILED WALL CLADDING
MF01710mm PLASTERBOARD CEILING
MF002
TIMBER SLAB
SOIL
MOISTURE INSULATION PARAPET METAL CAPPING
MF005
FOOTING TO ENGINEER
DETAIL
CONCRETE SLAB
MF001
INSULSPAN APPROVED
PANEL SEAL TAPE
BLOCKING TO BE
CARRIED OUT
BY PANEL
PREFABRICATOR
115mm STRUCTURAL
INSULATED PANEL
10mm PLASTERBOARD
MF002
10mm PLASTERBOARD
MF002
165mm STRUCTURAL
INSULATED PANEL
VAPOUR BARRIER SARKING
TIMBER BATTEN TO FORM
A VENTILATED CAVITY
TIMBER CLADDING
MF003
INSULSPAN APPROVED
PANEL SEAL TAPE
TIMBER BATTEN
BOX GUTTER min 1:100
FALL
VAPOUR BARRIER
SARKING
ROOF SHEETING
MF003
CAP FLASHING TO MATCH
THE COLOUR OF MF014
ROOF SHEETING
MF014
VAPOUR BARRIER
SARKING
165mm STRUCTURAL
INSULATED PANEL
INSULSPAN APPROVED
PANEL SEAL TAPE
INSULSPAN APPROVED
SEALANT
RIDGE BEAM
Notes
MF MATERIALS & FINISHES
Concrete SlabMF001
Refer to Finishes & Fixtures Schedule.
Paint - WhiteMF002
Refer to Finishes & Fixtures Schedule
Timber CladdingMF003
Refer to Finishes & Fixtures Schedule
Green RoofMF007
Refer to Finishes & Fixtures Schedule.
Roof Sheeting - ColorbondMF014
Refer to Finishes & Fixtures Schedule
Tiled Wall CladdingMF017
Refer to Finishes & Fixtures Schedule
1
1:20
DETAIL WALL SECTION 3
3
1:10
DETAIL ROOF & WALL JOINT
2
1:10
DETAIL ROOF RIDGE
28. 1607
DRAWN SCHEDULES
4 STOREY HOUSE
CONTRACT
DOCUMENTATION
J & E STOREY
6001
Title
Drawing Number Current Revision
All work to be in accordance with local
authority's building codes and standards,
The NCC/NZBC and all relevant and
current Aus/NZ Standards.
Verify all dimensions on site before
ordering materials or commencing
construction.
Contractor to notify architect immediately if
there are any discrepancies or errors in
the documentation.
Dimensions from stud for new
partitions/setout.
Dimensions from finished surface for all
existing partitions and for interior details,
joinery etc.
Drawings are design details only.
Contractor to provide shop drawings for
architects approval of all joinery elements
before commencing construction or
ordering materials. Provide finish samples
for architects approval before commencing
construction or ordering materials.
Do not scale off drawings. Use figured
dimensions only.
Status
Client
Project
Job Number
DOOR & WINDOW
SCHEDULE
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
Scale at A3
1:1
CheckedDrawn
JC JC
285 GOOCH STREET
THORNBURY VIC 3071 AUSTRALIA
REVISION DETAILS
ID DESCRIPTION DATE
A TENDER xx.xx.16
A
ELEVATION
2 883
2600
900
2600
900
2600
1 000
2600
2580
760 1 200
2600
450
1000
900
2400
585 585 585
1 755
2400
1 208 1 208 1 208 1 208
4 832
2800
1 360
2350
ID D01 D02 D03 D04 D05 D06 D07 D08 D09 D10 D11
Quantity 1 1 1 1 1 1 1 1 1 1 1
Height 2 600 2 600 2 600 2 600 2 560 2 600 1 000 2 400 2 400 2 800 2 350
Width 2 883 900 900 1 000 720 1 200 450 900 1 755 4 807 1 360
DOOR SCHEDULE
4 100
2800
3 313
2800
1500
450 450
1500
900
2400
900
2800
5 000
2224
1800
400
2 400
2400
1930
650
D12 D13 D14 D15 D16 D17 D18 D19 D20 D21
1 1 1 1 1 1 1 2 2 1
2 800 2 800 1 500 1 500 2 400 2 800 2 200 1 800 2 400 1 930
4 100 3 313 450 450 900 900 5 000 400 2 400 650
900
2400
1930
955
450
1780
800
1930
900
2100
900
2400
2 411
2400
D22 D23 D24 D25 D26 D27 D28
2 1 1 3 1 3 1
2 400 1 930 1 780 1 930 2 100 2 400 2 400
900 955 450 800 900 900 2 420
ID W01 W02 W03
Height 2 150 1 601 1 601
Width 500 2 600 2 600
Elevation
450
FFL
2600
FFL
2600
FFL
WINDOW SCHEDULE
ELEVATION
ID
Quantity
Height
Width
DOOR SCHEDULE
ELEVATION
ID
Quantity
Height
Width
DOOR SCHEDULE