This document provides plans and notes for an interior alteration project to combine two vacant business suites into a single dermatology office space. It includes a demolition plan showing elements to be removed, as well as code analysis information for the proposed occupancy. Responsibilities for the project include design, permits, and construction documents for the tenant buildout. Regulatory codes and standards are identified that will govern the work.
3. Pure Skin Dermatology- Healthcare Design
Responsabilities for Pure Skin Dermatology
- Site Analysis
- Programming
- Code Analysis
- Design Concepts
- Space Planning
- Reflected Ceiling Plan
- Construction Documents
- Furniture, Fixtures & Equipment
- Purchase Orders
- Site Visits
- Graphic Design Package
4. SCALE:
INTERIORALTERATIONFOR
PURESKINDERMATOLOGY
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
EGRESS PLAN GENERAL NOTES
EMERGENCY BATTERY PACK LIGHT FIXTURE.
TYPE ABC FIRE EXTINGUISHER MOUNTED NO MORE
THAN 5'-0" AFF TO HANDLE, AND BOTTOM NOT TO BE
LESS THAN 4" AFF. NFPA 10, TABLE 3-2.1. (PLACE NO
MORE THAN 75' APART, MAX)
EGRESS TRAVEL PATH. DISTANCE NOTED ON PLAN.
EXIT LIGHT FIXTURE. SHADED QUARTER (S)
DENOTE ILLUMINATED FACE (S).
PLAN SYMBOLS
FURNITURE AND OFFICE EQUIPMENT ARE SHOWN FOR LOCATION
ONLY. FURNITURE AND OFFICE EQUIPMENT ARE PROVIDED AND
INSTALLED BY TENANT'S VENDORS. IT IS THE RESPONSIBILITY OF
THE VENDORS TO FIELD VERIFTY AND ASSURE THAT A MINIMUM
OF 44" CLEAR CORRDIOR WIDTH IS PROVIDED THROUGHOUT
PLAN KEYED NOTES
1. REMOVE EXISTING GLAZING & FRAME FROM WALL. SEAL &
PATCH OPENING AS REQUIRED TO MATCH ADJACENT WALL.
DEMOLITION PLAN SYMBOLS
2. EXISTING PARTITION,GLAZING & FRAME TO BE REMOVED
3. EXISTING MOP SINK TO BE REMOVED.
4. CREATE A 36" X 84" OPENING WITHIN WALL FOR A NEW
CASED OPENING.
5. DASHED LINES INDICATE PORTION OF EXISTING WALL TO BE
DEMOED. STOP DEMO @ 18" FROM DOOR.
INDICATES EXISTING INTERIOR PARTITION TO BE
REMOVED.
INDICATES EXISTING DOOR TO REMAIN
INDICATES EXISTING DOOR TO BE REMOVEDA. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS
PRIOR TO START OF WORK.
B. CONTRACTOR SHALL COORDINATE ALL DEMOLITION
WORK THE NEW WORK PLAN PRIOR TO START
DEMOLITION.
C. CONTRACTOR SHALL COORDINATE W/ OWNER ALL
MATERIALS TO BE SALVAGED BEFORE START OR
DEMOLITION WORK.
D. CONTRACTOR SHALL VERIFY LAYOUT INFORMATION
SHOWN ON DRAWINGS BEFORE START OF DEMOLITION
WORK. AS WORK PROCEEDS, CHECK EVERY ELEMENT
AND MAINTAIN AN ACCURATE LOS OF SUCH CHECK.
RECORD DEVIATIONS AND ADVISE ARCHITECT
PROMPTLY UPON DETECTION RECORD DEVIATIONS
ACCEPTED OR CORRECTED ON RECORD DRAWINGS.
E. CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL
SELECTIVE DEMOTION REQ'D TO ACCOMMODATE ALL
NEW CONSTRUCTION AND RENOVATION WORK,
WHETHER OR NOT ACTUALLY INDICATED ON DRAWINGS
OR DESCRIBED IN CONTRACT DOCUMENTS.
F. ANY DAMAGE TO EXISTING RATED WALLS OR
FLOOR/CEILING ASSEMBLIES MUST BE PATCHED AS
REQ'D TO MAINTAIN FIRE RATING, AT NO ADDITIONAL
COST TO THE OWNER.
G. ALL EXISTING FIXTURES & MILLWORK TO REMAIN U.O.N.
6. DEMO PORTION OF EXISTING WALL TO CREATE AN ARCHED
HEADER AT 9'-0" A.F.F.
7. REMOVE EXISTING CABINET & SINK. SALVAGE EXISTING SINK FOR
RE-USE IN NEW MILLWORK CABINETRY. REFER TO NEW FLOOR
PLAN FOR LOCATION OF SINK AND NEW MILLWORK.
DEMOLITION GENERAL NOTES
CONSTRUCTION TYPE: TYPE IlB PROTECTED
SPRINKLERED OR NON-SPRINKLERED: SPRINKLERED
NUMBER OF STORIES: 3 STORY
BUILDING:
PLUMBING:
MECHANICAL:
ELECTRICAL:
FIRE:
LIFE SAFETY:
FBC 2010 ED., EXISTING. BLDG. W/ 2009 SUPPLEMENTS
NATIONAL ELECTRICAL CODE 2010 EDITION
FL.2010 EDITION (2006 NFPA 101 LSC)
FL.2010 EDITION (2006 NFPA 1-UNIFORM FIRE CODE)
JURISDICTION AUTHORITY:
BLDG OCCUPANCY CLASSIFICATION: BUSINESS
ACCESSIBILITY: CHPT 11, FBC 2007 ED. W/ 2010 SUPPLEMENTS
FBC 2010 ED. W/ 2009 SUPPLEMENTS
FBC 2010 ED. W/ 2009 SUPPLEMENTS
ADDRESS
SCOPE OF WORK NARRATIVE:
APPLICABLE CODES:
JURISDICTION:
SHELL BUILDING CONSTRUCTION
TENANT ANALYSIS:
EGRESS:
EXITS:
MIN. EXIT DOORS REQUIRED: 2
EXIT DOORS PROVIDED: 4*
WATER CLOSETS REQUIRED
2
WATER CLOSETS PROVIDED: 3 (EXISTING)
LAVATORIES REQUIRED:
1 PER 40 FOR FIRST 80
LAVATORIES PROVIDED: 3 (EXISTING)
DRINKING FOUNTAINS REQUIRED 1
DRINKING FOUNTAIN PROVIDED 4 (EXISTING)
1 PER 25 FOR FIRST 50:
1
PLUMBING CALCULATIONS:
SERVICE SINK REQUIRED 0
SERVICE SINK PROVIDED 0
EGRESS WIDTH PER OCCUPANT: .2" PER FBC 1005.1
MAXIMUM OCCUPANTS: 28
MIN. REQUIRED EGRESS WIDTH: 5.6" LIN. IN
EGRESS WIDTH PROVIDED: 128" LIN. IN*
MAX TRAVEL DIST. ALLOWED 300' PER FBC 1016.1
MAX TRAVEL DISTANCE 176'-0"
MAX DEAD END ALLOWED 50'
MAX DEAD END N/A
MIN. CORRIDOR WIDTH REQUIRED: 44"
*NOTE: 4 EXISTING 36" DOORS
GROSS AREA 2,731 S.F.
PROPOSED USE: BUSINESS (DERMATOLOGIST OFFICE)
S.F./OCC. 100 GROSS
OCC. LOAD 28
PHONE
*4 EXISTING 36" DOORS
ORANGE COUNTY
201 S ROSALIND AVE, 1ST FL
ORLANDO FL 32802
407.836.5550
DRAWING SYMBOLS
REVISION
DOOR DESIGNATION ROOM IDENTIFIER:
CEILING HEIGHT
PLAN KEYNOTE TAG: PARTITION TYPE
DETAIL/ENLARGE PLAN ELEVATION TAG
ELEVATION TAG
SECTION TAGEQUIPMENT TAG
ELEVATION TARGET/
DOOR
NUMBER
REVISED
AREA
REVISION
NUMBER
DRAWING NO.
SHEET NO.
AREA TO BE
DETAILED OR
ENLARGED
DRAWING NO.
SHEET NO.
DRAWING NO.
SHEET NO.
DRAWING NO.
SHEET NO.
CASED OPENING
SHEET INDEX
CODE SUMMARY, EGRESS, AND DEMO PLANCS
NEW FLOOR PLAN AND REFLECTED CEILING PLANID.1
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
VICINITY MAP
BLDG.
LOCATION
THE
ESPLANADE
DR PHILLIPS
BLVD
D
ELLA
DR
LIT
TLE
SAND
LAKE
TU
R
KEY
LAKE
RD
A
PO
PK
A
VIN
ELAN
D
W
SAN
DLAKE
R
D.
W
SAN
DLAKE
R
D.
TU
R
KEY
LAKE
RD
I-4
EAST
BO
UND
KEY PLAN 2ND FLOOR
EXISTING 1 HR RATED DEMISING WALL
INTERIOR FINISHES REQUIREMENTS:
GROUP: B SPRINKLERED
EXITS AND EXIT PASSAGEWAYS: B
CORRIDORS C
ROOMS & ENCLOSED SPACES B
AREA OF WORK:
SUITES 205 AND 206
INTERIOR ALTERATION TO AN EXISTING SHELL. THE ALTERATION
WILL COMBINE TWO EXISTING VACANT BUSINESS SUITES (SUITES
205 AND 206) INTO ONE SPACE TO BE USED AND OCCUPIED BY
ONE DERMATOLOGIST. THE SCOPE OF WORK IS LIMITED TO:
MINOR DEMO, NEW INTERIOR PARTITIONS, NEW FINISHES, AND
ELECTRICAL LIGHTING.
ALL NEW HAND SINKS AS PART OF MILLWORK SHOWN ON PLANS
SHALL CONNECT TO THE EXISTING PLUMBING LINES LOCATED
WITHIN THE EXISTING WALLS. THE PLUMBING LINES AND
CONNECTIONS ARE SHOWN IN THE PREVIOUS TENANT'S BUILD
OUT PLANS, SHEET A-2, PERMIT #B06903223. NO WORK IS
PROPOSED TO ALTER THE EXISTING PLUMBING SYSTEM,
MECHANICAL SYSTEM, OR THE BUILDING ENVELOPE.
ALL NEW FIXTURES AND EQUIPMENT SHOWN ON PLANS ARE FOR
LOCATION AND DESIGN INTENT ONLY. MECHANICAL, ELECTRICAL,
AND PLUMBING ENGINEERING IF REQUIRED, FOR PERMITS IS
OUTSIDE THE SCOPE OF THESE DOCUMENTS.
PREVIOUS USE: BUSINESS
0'-0" EGRESS WIDTH PROVIDED. 0'-0" INDICATES
WIDTH IN LINEAL INCHES
RODERICK JIMENEZ
I-4
W
EST
BO
UND
INDICATES EXISTING PARTITION/WALL TO REMAIN.
EXISTING 1 HR RATED DEMISING WALL
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
BO BOTTOM OF
BD BOARD
CEIL CEILING
CPT CARPET
CT CERAMIC TILE
GA. GUAGE
GYP GYPSUM
HT HEIGHT
LF LINEAL FEET
LI LINEAL INCHES
ABBREVIATIONS
MTL METAL
NIC NOT IN CONTRACT
NSF NET SQUARE FEET
OCC OCCUPANTS
PT PRESSURE TREATED
REQ REQUIRED
SF SQUARE FEET
T.O. TOP OF
UON UNLESS OTHERWISE NOTED
VCT VINYL COMPOSITION TILE
WD WOOD
SCALE:
SCALE:
INTERIORALTERATIONFOR
PURESKINDERMATOLOGY
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
EGRESS PLAN GENERAL NOTES
EMERGENCY BATTERY PACK LIGHT FIXTURE.
TYPE ABC FIRE EXTINGUISHER MOUNTED NO MORE
THAN 5'-0" AFF TO HANDLE, AND BOTTOM NOT TO BE
LESS THAN 4" AFF. NFPA 10, TABLE 3-2.1. (PLACE NO
MORE THAN 75' APART, MAX)
EGRESS TRAVEL PATH. DISTANCE NOTED ON PLAN.
EXIT LIGHT FIXTURE. SHADED QUARTER (S)
DENOTE ILLUMINATED FACE (S).
PLAN SYMBOLS
FURNITURE AND OFFICE EQUIPMENT ARE SHOWN FOR LOCATION
ONLY. FURNITURE AND OFFICE EQUIPMENT ARE PROVIDED AND
INSTALLED BY TENANT'S VENDORS. IT IS THE RESPONSIBILITY OF
THE VENDORS TO FIELD VERIFTY AND ASSURE THAT A MINIMUM
OF 44" CLEAR CORRDIOR WIDTH IS PROVIDED THROUGHOUT
PLAN KEYED NOTES
1. REMOVE EXISTING GLAZING & FRAME FROM WALL. SEAL &
PATCH OPENING AS REQUIRED TO MATCH ADJACENT WALL.
DEMOLITION PLAN SYMBOLS
2. EXISTING PARTITION,GLAZING & FRAME TO BE REMOVED
3. EXISTING MOP SINK TO BE REMOVED.
4. CREATE A 36" X 84" OPENING WITHIN WALL FOR A NEW
CASED OPENING.
5. DASHED LINES INDICATE PORTION OF EXISTING WALL TO BE
DEMOED. STOP DEMO @ 18" FROM DOOR.
INDICATES EXISTING INTERIOR PARTITION TO BE
REMOVED.
INDICATES EXISTING DOOR TO REMAIN
INDICATES EXISTING DOOR TO BE REMOVEDA. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS
PRIOR TO START OF WORK.
B. CONTRACTOR SHALL COORDINATE ALL DEMOLITION
WORK THE NEW WORK PLAN PRIOR TO START
DEMOLITION.
C. CONTRACTOR SHALL COORDINATE W/ OWNER ALL
MATERIALS TO BE SALVAGED BEFORE START OR
DEMOLITION WORK.
D. CONTRACTOR SHALL VERIFY LAYOUT INFORMATION
SHOWN ON DRAWINGS BEFORE START OF DEMOLITION
WORK. AS WORK PROCEEDS, CHECK EVERY ELEMENT
AND MAINTAIN AN ACCURATE LOS OF SUCH CHECK.
RECORD DEVIATIONS AND ADVISE ARCHITECT
PROMPTLY UPON DETECTION RECORD DEVIATIONS
ACCEPTED OR CORRECTED ON RECORD DRAWINGS.
E. CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL
SELECTIVE DEMOTION REQ'D TO ACCOMMODATE ALL
NEW CONSTRUCTION AND RENOVATION WORK,
WHETHER OR NOT ACTUALLY INDICATED ON DRAWINGS
OR DESCRIBED IN CONTRACT DOCUMENTS.
F. ANY DAMAGE TO EXISTING RATED WALLS OR
FLOOR/CEILING ASSEMBLIES MUST BE PATCHED AS
REQ'D TO MAINTAIN FIRE RATING, AT NO ADDITIONAL
COST TO THE OWNER.
G. ALL EXISTING FIXTURES & MILLWORK TO REMAIN U.O.N.
6. DEMO PORTION OF EXISTING WALL TO CREATE AN ARCHED
HEADER AT 9'-0" A.F.F.
7. REMOVE EXISTING CABINET & SINK. SALVAGE EXISTING SINK FOR
RE-USE IN NEW MILLWORK CABINETRY. REFER TO NEW FLOOR
PLAN FOR LOCATION OF SINK AND NEW MILLWORK.
DEMOLITION GENERAL NOTES
CONSTRUCTION TYPE: TYPE IlB PROTECTED
SPRINKLERED OR NON-SPRINKLERED: SPRINKLERED
NUMBER OF STORIES: 3 STORY
BUILDING:
PLUMBING:
MECHANICAL:
ELECTRICAL:
FIRE:
LIFE SAFETY:
FBC 2010 ED., EXISTING. BLDG. W/ 2009 SUPPLEMENTS
NATIONAL ELECTRICAL CODE 2010 EDITION
FL.2010 EDITION (2006 NFPA 101 LSC)
FL.2010 EDITION (2006 NFPA 1-UNIFORM FIRE CODE)
JURISDICTION AUTHORITY:
BLDG OCCUPANCY CLASSIFICATION: BUSINESS
ACCESSIBILITY: CHPT 11, FBC 2007 ED. W/ 2010 SUPPLEMENTS
FBC 2010 ED. W/ 2009 SUPPLEMENTS
FBC 2010 ED. W/ 2009 SUPPLEMENTS
ADDRESS
APPLICABLE CODES:
JURISDICTION:
SHELL BUILDING CONSTRUCTION
TENANT ANALYSIS:
EGRESS:
EXITS:
MIN. EXIT DOORS REQUIRED: 2
EXIT DOORS PROVIDED: 4*
WATER CLOSETS REQUIRED
2
WATER CLOSETS PROVIDED: 3 (EXISTING)
LAVATORIES REQUIRED:
1 PER 40 FOR FIRST 80
LAVATORIES PROVIDED: 3 (EXISTING)
DRINKING FOUNTAINS REQUIRED 1
DRINKING FOUNTAIN PROVIDED 4 (EXISTING)
1 PER 25 FOR FIRST 50:
1
PLUMBING CALCULATIONS:
SERVICE SINK REQUIRED 0
SERVICE SINK PROVIDED 0
EGRESS WIDTH PER OCCUPANT: .2" PER FBC 1005.1
MAXIMUM OCCUPANTS: 28
MIN. REQUIRED EGRESS WIDTH: 5.6" LIN. IN
EGRESS WIDTH PROVIDED: 128" LIN. IN*
MAX TRAVEL DIST. ALLOWED 300' PER FBC 1016.1
MAX TRAVEL DISTANCE 176'-0"
MAX DEAD END ALLOWED 50'
MAX DEAD END N/A
MIN. CORRIDOR WIDTH REQUIRED: 44"
*NOTE: 4 EXISTING 36" DOORS
GROSS AREA 2,731 S.F.
PROPOSED USE: BUSINESS (DERMATOLOGIST OFFICE)
S.F./OCC. 100 GROSS
OCC. LOAD 28
PHONE
*4 EXISTING 36" DOORS
ORANGE COUNTY
201 S ROSALIND AVE, 1ST FL
ORLANDO FL 32802
407.836.5550
DRAWING SYMBOLS
REVISION
DOOR DESIGNATION ROOM IDENTIFIER:
CEILING HEIGHT
PLAN KEYNOTE TAG: PARTITION TYPE
DETAIL/ENLARGE PLAN ELEVATION TAG
ELEVATION TAG
SECTION TAGEQUIPMENT TAG
ELEVATION TARGET/
DOOR
NUMBER
REVISED
AREA
REVISION
NUMBER
DRAWING NO.
SHEET NO.
AREA TO BE
DETAILED OR
ENLARGED
DRAWING NO.
SHEET NO.
DRAWING NO.
SHEET NO.
DRAWING NO.
SHEET NO.
CASED OPENING
SIZE NOTED ON PLAN
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
BLDG.
LOCATION
HE
ESPLANADE
DR PHILLIPS
BLVD
D
ELLA
DR
LIT
TLE
SAND
LAKE
TU
R
KEY
LAKE
RD
O
PK
A
VIN
ELAN
D
W
SAN
DLAKE
R
D.
W
SAN
DLAKE
R
D.
TU
R
KEY
LAKE
RD
I-4
EAST
BO
UND
EXISTING 1 HR RATED DEMISING WALL
INTERIOR FINISHES REQUIREMENTS:
GROUP: B SPRINKLERED
EXITS AND EXIT PASSAGEWAYS: B
CORRIDORS C
ROOMS & ENCLOSED SPACES B
205 AND 206) INTO ONE SPACE TO BE USED AND OCCUPIED BY
ONE DERMATOLOGIST. THE SCOPE OF WORK IS LIMITED TO:
MINOR DEMO, NEW INTERIOR PARTITIONS, NEW FINISHES, AND
ELECTRICAL LIGHTING.
ALL NEW HAND SINKS AS PART OF MILLWORK SHOWN ON PLANS
SHALL CONNECT TO THE EXISTING PLUMBING LINES LOCATED
WITHIN THE EXISTING WALLS. THE PLUMBING LINES AND
CONNECTIONS ARE SHOWN IN THE PREVIOUS TENANT'S BUILD
OUT PLANS, SHEET A-2, PERMIT #B06903223. NO WORK IS
PROPOSED TO ALTER THE EXISTING PLUMBING SYSTEM,
MECHANICAL SYSTEM, OR THE BUILDING ENVELOPE.
ALL NEW FIXTURES AND EQUIPMENT SHOWN ON PLANS ARE FOR
LOCATION AND DESIGN INTENT ONLY. MECHANICAL, ELECTRICAL,
AND PLUMBING ENGINEERING IF REQUIRED, FOR PERMITS IS
OUTSIDE THE SCOPE OF THESE DOCUMENTS.
PREVIOUS USE: BUSINESS
0'-0" EGRESS WIDTH PROVIDED. 0'-0" INDICATES
WIDTH IN LINEAL INCHES
RODERICK JIMENEZ
I-4
W
EST
BO
UND
INDICATES EXISTING PARTITION/WALL TO REMAIN.
EXISTING 1 HR RATED DEMISING WALL
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
BO BOTTOM OF
BD BOARD
CEIL CEILING
CPT CARPET
CT CERAMIC TILE
GA. GUAGE
GYP GYPSUM
HT HEIGHT
LF LINEAL FEET
LI LINEAL INCHES
ABBREVIATIONS
MTL METAL
NIC NOT IN CONTRACT
NSF NET SQUARE FEET
OCC OCCUPANTS
PT PRESSURE TREATED
REQ REQUIRED
SF SQUARE FEET
T.O. TOP OF
UON UNLESS OTHERWISE NOTED
VCT VINYL COMPOSITION TILE
WD WOOD
SCALE:
SCALE:
INTERIORALTERATIONFOR
PURESKINDERMATOLOGY
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
EGRESS PLAN GENERAL NOTES
EMERGENCY BATTERY PACK LIGHT FIXTURE.
TYPE ABC FIRE EXTINGUISHER MOUNTED NO MORE
THAN 5'-0" AFF TO HANDLE, AND BOTTOM NOT TO BE
LESS THAN 4" AFF. NFPA 10, TABLE 3-2.1. (PLACE NO
MORE THAN 75' APART, MAX)
EGRESS TRAVEL PATH. DISTANCE NOTED ON PLAN.
EXIT LIGHT FIXTURE. SHADED QUARTER (S)
DENOTE ILLUMINATED FACE (S).
PLAN SYMBOLS
FURNITURE AND OFFICE EQUIPMENT ARE SHOWN FOR LOCATION
ONLY. FURNITURE AND OFFICE EQUIPMENT ARE PROVIDED AND
INSTALLED BY TENANT'S VENDORS. IT IS THE RESPONSIBILITY OF
THE VENDORS TO FIELD VERIFTY AND ASSURE THAT A MINIMUM
OF 44" CLEAR CORRDIOR WIDTH IS PROVIDED THROUGHOUT
PLAN KEYED NOTES
1. REMOVE EXISTING GLAZING & FRAME FROM WALL. SEAL &
PATCH OPENING AS REQUIRED TO MATCH ADJACENT WALL.
DEMOLITION PLAN SYMBOLS
2. EXISTING PARTITION,GLAZING & FRAME TO BE REMOVED
3. EXISTING MOP SINK TO BE REMOVED.
4. CREATE A 36" X 84" OPENING WITHIN WALL FOR A NEW
CASED OPENING.
5. DASHED LINES INDICATE PORTION OF EXISTING WALL TO BE
DEMOED. STOP DEMO @ 18" FROM DOOR.
INDICATES EXISTING INTERIOR PARTITION TO BE
REMOVED.
INDICATES EXISTING DOOR TO REMAIN
INDICATES EXISTING DOOR TO BE REMOVEDA. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS
PRIOR TO START OF WORK.
B. CONTRACTOR SHALL COORDINATE ALL DEMOLITION
WORK THE NEW WORK PLAN PRIOR TO START
DEMOLITION.
C. CONTRACTOR SHALL COORDINATE W/ OWNER ALL
MATERIALS TO BE SALVAGED BEFORE START OR
DEMOLITION WORK.
D. CONTRACTOR SHALL VERIFY LAYOUT INFORMATION
SHOWN ON DRAWINGS BEFORE START OF DEMOLITION
WORK. AS WORK PROCEEDS, CHECK EVERY ELEMENT
AND MAINTAIN AN ACCURATE LOS OF SUCH CHECK.
RECORD DEVIATIONS AND ADVISE ARCHITECT
PROMPTLY UPON DETECTION RECORD DEVIATIONS
ACCEPTED OR CORRECTED ON RECORD DRAWINGS.
E. CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL
SELECTIVE DEMOTION REQ'D TO ACCOMMODATE ALL
NEW CONSTRUCTION AND RENOVATION WORK,
WHETHER OR NOT ACTUALLY INDICATED ON DRAWINGS
OR DESCRIBED IN CONTRACT DOCUMENTS.
F. ANY DAMAGE TO EXISTING RATED WALLS OR
FLOOR/CEILING ASSEMBLIES MUST BE PATCHED AS
REQ'D TO MAINTAIN FIRE RATING, AT NO ADDITIONAL
COST TO THE OWNER.
G. ALL EXISTING FIXTURES & MILLWORK TO REMAIN U.O.N.
6. DEMO PORTION OF EXISTING WALL TO CREATE AN ARCHED
HEADER AT 9'-0" A.F.F.
7. REMOVE EXISTING CABINET & SINK. SALVAGE EXISTING SINK FOR
RE-USE IN NEW MILLWORK CABINETRY. REFER TO NEW FLOOR
PLAN FOR LOCATION OF SINK AND NEW MILLWORK.
DEMOLITION GENERAL NOTES
CONSTRUCTION TYPE: TYPE IlB PROTECTED
SPRINKLERED OR NON-SPRINKLERED: SPRINKLERED
NUMBER OF STORIES: 3 STORY
BUILDING:
PLUMBING:
MECHANICAL:
ELECTRICAL:
FIRE:
LIFE SAFETY:
FBC 2010 ED., EXISTING. BLDG. W/ 2009 SUPPLEMENTS
NATIONAL ELECTRICAL CODE 2010 EDITION
FL.2010 EDITION (2006 NFPA 101 LSC)
FL.2010 EDITION (2006 NFPA 1-UNIFORM FIRE CODE)
JURISDICTION AUTHORITY:
BLDG OCCUPANCY CLASSIFICATION: BUSINESS
ACCESSIBILITY: CHPT 11, FBC 2007 ED. W/ 2010 SUPPLEMENTS
FBC 2010 ED. W/ 2009 SUPPLEMENTS
FBC 2010 ED. W/ 2009 SUPPLEMENTS
ADDRESS
SCOPE OF WORK NARRATIVE:
APPLICABLE CODES:
JURISDICTION:
SHELL BUILDING CONSTRUCTION
TENANT ANALYSIS:
EGRESS:
EXITS:
MIN. EXIT DOORS REQUIRED: 2
EXIT DOORS PROVIDED: 4*
WATER CLOSETS REQUIRED
2
WATER CLOSETS PROVIDED: 3 (EXISTING)
LAVATORIES REQUIRED:
1 PER 40 FOR FIRST 80
LAVATORIES PROVIDED: 3 (EXISTING)
DRINKING FOUNTAINS REQUIRED 1
DRINKING FOUNTAIN PROVIDED 4 (EXISTING)
1 PER 25 FOR FIRST 50:
1
PLUMBING CALCULATIONS:
SERVICE SINK REQUIRED 0
SERVICE SINK PROVIDED 0
EGRESS WIDTH PER OCCUPANT: .2" PER FBC 1005.1
MAXIMUM OCCUPANTS: 28
MIN. REQUIRED EGRESS WIDTH: 5.6" LIN. IN
EGRESS WIDTH PROVIDED: 128" LIN. IN*
MAX TRAVEL DIST. ALLOWED 300' PER FBC 1016.1
MAX TRAVEL DISTANCE 176'-0"
MAX DEAD END ALLOWED 50'
MAX DEAD END N/A
MIN. CORRIDOR WIDTH REQUIRED: 44"
*NOTE: 4 EXISTING 36" DOORS
GROSS AREA 2,731 S.F.
PROPOSED USE: BUSINESS (DERMATOLOGIST OFFICE)
S.F./OCC. 100 GROSS
OCC. LOAD 28
PHONE
*4 EXISTING 36" DOORS
ORANGE COUNTY
201 S ROSALIND AVE, 1ST FL
ORLANDO FL 32802
407.836.5550
DRAWING SYMBOLS
REVISION
DOOR DESIGNATION ROOM IDENTIFIER:
CEILING HEIGHT
PLAN KEYNOTE TAG: PARTITION TYPE
DETAIL/ENLARGE PLAN ELEVATION TAG
ELEVATION TAG
SECTION TAGEQUIPMENT TAG
ELEVATION TARGET/
DOOR
NUMBER
REVISED
AREA
REVISION
NUMBER
DRAWING NO.
SHEET NO.
AREA TO BE
DETAILED OR
ENLARGED
DRAWING NO.
SHEET NO.
DRAWING NO.
SHEET NO.
DRAWING NO.
SHEET NO.
CASED OPENING
SIZE NOTED ON PLAN
SHEET INDEX
CODE SUMMARY, EGRESS, AND DEMO PLANCS
NEW FLOOR PLAN AND REFLECTED CEILING PLANID.1
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
VICINITY MAP
BLDG.
LOCATION
THE
ESPLANADE
DR PHILLIPS
BLVD
D
ELLA
DR
LIT
TLE
SAND
LAKE
TU
R
KEY
LAKE
RD
A
PO
PK
A
VIN
ELAN
D
W
SAN
DLAKE
R
D.
W
SAN
DLAKE
R
D.
TU
R
KEY
LAKE
RD
I-4
EAST
BO
UND
KEY PLAN 2ND FLOOR
EXISTING 1 HR RATED DEMISING WALL
INTERIOR FINISHES REQUIREMENTS:
GROUP: B SPRINKLERED
EXITS AND EXIT PASSAGEWAYS: B
CORRIDORS C
ROOMS & ENCLOSED SPACES B
AREA OF WORK:
SUITES 205 AND 206
INTERIOR ALTERATION TO AN EXISTING SHELL. THE ALTERATION
WILL COMBINE TWO EXISTING VACANT BUSINESS SUITES (SUITES
205 AND 206) INTO ONE SPACE TO BE USED AND OCCUPIED BY
ONE DERMATOLOGIST. THE SCOPE OF WORK IS LIMITED TO:
MINOR DEMO, NEW INTERIOR PARTITIONS, NEW FINISHES, AND
ELECTRICAL LIGHTING.
ALL NEW HAND SINKS AS PART OF MILLWORK SHOWN ON PLANS
SHALL CONNECT TO THE EXISTING PLUMBING LINES LOCATED
WITHIN THE EXISTING WALLS. THE PLUMBING LINES AND
CONNECTIONS ARE SHOWN IN THE PREVIOUS TENANT'S BUILD
OUT PLANS, SHEET A-2, PERMIT #B06903223. NO WORK IS
PROPOSED TO ALTER THE EXISTING PLUMBING SYSTEM,
MECHANICAL SYSTEM, OR THE BUILDING ENVELOPE.
ALL NEW FIXTURES AND EQUIPMENT SHOWN ON PLANS ARE FOR
LOCATION AND DESIGN INTENT ONLY. MECHANICAL, ELECTRICAL,
AND PLUMBING ENGINEERING IF REQUIRED, FOR PERMITS IS
OUTSIDE THE SCOPE OF THESE DOCUMENTS.
PREVIOUS USE: BUSINESS
0'-0" EGRESS WIDTH PROVIDED. 0'-0" INDICATES
WIDTH IN LINEAL INCHES
RODERICK JIMENEZ
I-4
W
EST
BO
UND
INDICATES EXISTING PARTITION/WALL TO REMAIN.
EXISTING 1 HR RATED DEMISING WALL
SCALE: SCALE:
1. NEW MILLWORK BY CONTRACTOR.
2. NEW 3070 CASED OPENING WITHIN WALL
3. NEW HAND SINK AND MILLWORK BY
CONTRACTOR. PLUMBER SHALL CONNECT
NEW HAND SINK TO EXISTING PLUMBING LINES
LOCATED WITHIN EXISTING WALLS.
4. EXISTING SINK SALVAGED FROM DEMO &
RE-USED IN NEW MILLWORK. CONNECT TO
EXISTING PLUMBING LINES WITHIN EXISTING
WALL.
5. DASHED LINES INDICATE NEW ARCHED HEADER
AT 9'-0" AFF.
6. WASHER DRYER PROVIDED BY & INSTALLED BY
OWNER.
7. NEW CLERESTORY GLAZING WITHIN WALL.
COORDINATE WITH TENANT FOR
SPECIFICATIONS AND REQUIREMENTS.
FLOOR PLAN KEYED NOTESFLOOR PLAN GENERAL NOTES
FLOOR PLAN SYMBOLS
EXISTING 1-HR RATED WALL
NEW INTERIOR PARTITION
EXISTING INTERIOR PARTITION
REFLECTED CEILING SYMBOLSREFLECTED CEILING GENERAL NOTES
EXISTING 2 X 4 RECESSED FLUORESCENT
FIXTURE
EXISTING ACOUSTICAL CEILING TILE AND
GRID SYSTEM.
EXISTING EXHAUST FAN
EXISTING EXIT LIGHT FIXTURE. SHADED
QUARTER(S) DENOTE ILLUMINATED FACE(S).
EXISTING EMERGENCY LIGHT WITH
BATTERY PACK
REFLECTED CEILING KEY NOTES
EXISTING AIR DIFFUSER
EXISTING AIR RETURN
1. HATCHED AREA INDICATES NEW ARCHED HEADER
@ 9'-0" A.F.F.
2. HATCHED AREA INDICATES PORTION OF EXISTING
CEILING GRID TO BE PATCHED & REPAIRED AS
REQUIRED TO MATCH EXISTING ADJACENT.
3. NEW SOFFIT @ 8'-6" A.F.F. TO FOLLOW EDGE OF
RECEPTION DESK BELOW.
DERMATOLOGY CHAIR BY CLIENT
RM RM NAME FLOOR
WALL
BASE
WALL
S
EXISTING RECESSED DOWN LIGHT
NEW CEILING EXAM LIGHT BY OWNER AND
INSTALLED BY ELECTRICIAN. COORDINATE WITH
OWNER FOR MOUNTING LOCATION &
REQUIREMENTS.
A. CONTRACTOR SHALL VERIFY ALL EXISTING
CONDITIONS PRIOR TO START OR CONSTRUCTION.
B. PROVIDE WOOD BLOCKING IN EXISTING WALLS AS
REQUIRED FOR NEW COUNTERS, CABINETS, SYSTEMS
FURNITURE, DEVICES, AND EQUIPMENT. PATCH WALL
AT ALL AREAS DISTURBED BY INSTALLATION OF NEW
BLOCKING.
C. VERIFY LAYOUT INFORMATION SHOWN ON DRAWINGS
BEFORE PROCEEDING WITH ACTUAL WORK. AS WORK
PROCEEDS, CHECK EVERY ELEMENT AND MAINTAIN AN
ACCURATE LOG OF SUCH CHECKS. RECORD
DEVIATIONS AND ADVISE ARCHITECT PROMPTLY UPON
DETECTION. RECORD DEVIATIONS ACCEPTED OR
CORRECTED ON RECORD DRAWINGS.
D. ALL FIXTURES , DEVICES, & MILLWORK ARE EXISTING
U.O.N.
A. ALL ITEMS SHOWN ON REFLECTED CEILING PLAN
ARE EXISTING U.O.N.
B. EXISTING CEILING HEIGHT AT 9'-6"
WALL TYPE TAG
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
NOTE: PLUMBING LINES FOR NEW HAND
SINKS IN SUITE 206 ARE EXISTING AND
LOCATED WITHIN EXISTING WALLS. (REFER
TO PREVIOUS TENANT'S PERMIT PLANS
SHEET A-2 PERMIT #B06903223). SINKS AND
MILLWORK PROVIDED BY TENANT AND
CONNECTED BY PLUMBER.
NOTE: ALL NEW CEILING LIGHT FIXTURES AND
DEVICES ARE SHOWN FOR LOCATION AND
DESIGN INTENT ONLY. ALL ENGINEERING FOR
PERMITS, IF REQUIRED, IS OUTSIDE THE SCOPE
OF THESE DOCUMENTS.
NEW WALL TYPES
NEW PENDANT LIGHT
P
SCALE:
NEW RECESSED DOWN LIGHT
INTERIORALTERATIONFOR
PURESKINDERMATOLOGY
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
RODERICK JIMENEZ
SCALE: SCALE:
1. NEW MILLWORK BY CONTRACTOR.
2. NEW 3070 CASED OPENING WITHIN WALL
3. NEW HAND SINK AND MILLWORK BY
CONTRACTOR. PLUMBER SHALL CONNECT
NEW HAND SINK TO EXISTING PLUMBING LINES
LOCATED WITHIN EXISTING WALLS.
4. EXISTING SINK SALVAGED FROM DEMO &
RE-USED IN NEW MILLWORK. CONNECT TO
EXISTING PLUMBING LINES WITHIN EXISTING
WALL.
5. DASHED LINES INDICATE NEW ARCHED HEADER
AT 9'-0" AFF.
6. WASHER DRYER PROVIDED BY & INSTALLED BY
OWNER.
7. NEW CLERESTORY GLAZING WITHIN WALL.
COORDINATE WITH TENANT FOR
SPECIFICATIONS AND REQUIREMENTS.
FLOOR PLAN KEYED NOTESFLOOR PLAN GENERAL NOTES
FLOOR PLAN SYMBOLS
EXISTING 1-HR RATED WALL
NEW INTERIOR PARTITION
EXISTING INTERIOR PARTITION
REFLECTED CEILING SYMBOLSREFLECTED CEILING GENERAL NOTES
EXISTING 2 X 4 RECESSED FLUORESCENT
FIXTURE
EXISTING ACOUSTICAL CEILING TILE AND
GRID SYSTEM.
EXISTING EXHAUST FAN
EXISTING EXIT LIGHT FIXTURE. SHADED
QUARTER(S) DENOTE ILLUMINATED FACE(S).
EXISTING EMERGENCY LIGHT WITH
BATTERY PACK
REFLECTED CEILING KEY NOTES
EXISTING AIR DIFFUSER
EXISTING AIR RETURN
1. HATCHED AREA INDICATES NEW ARCHED HEADER
@ 9'-0" A.F.F.
2. HATCHED AREA INDICATES PORTION OF EXISTING
CEILING GRID TO BE PATCHED & REPAIRED AS
REQUIRED TO MATCH EXISTING ADJACENT.
3. NEW SOFFIT @ 8'-6" A.F.F. TO FOLLOW EDGE OF
RECEPTION DESK BELOW.
DERMATOLOGY CHAIR BY CLIENT
RM RM NAME FLOOR
WALL
BASE
WALL
S
EXISTING RECESSED DOWN LIGHT
NEW CEILING EXAM LIGHT BY OWNER AND
INSTALLED BY ELECTRICIAN. COORDINATE WITH
OWNER FOR MOUNTING LOCATION &
REQUIREMENTS.
A. CONTRACTOR SHALL VERIFY ALL EXISTING
CONDITIONS PRIOR TO START OR CONSTRUCTION.
B. PROVIDE WOOD BLOCKING IN EXISTING WALLS AS
REQUIRED FOR NEW COUNTERS, CABINETS, SYSTEMS
FURNITURE, DEVICES, AND EQUIPMENT. PATCH WALL
AT ALL AREAS DISTURBED BY INSTALLATION OF NEW
BLOCKING.
C. VERIFY LAYOUT INFORMATION SHOWN ON DRAWINGS
BEFORE PROCEEDING WITH ACTUAL WORK. AS WORK
PROCEEDS, CHECK EVERY ELEMENT AND MAINTAIN AN
ACCURATE LOG OF SUCH CHECKS. RECORD
DEVIATIONS AND ADVISE ARCHITECT PROMPTLY UPON
DETECTION. RECORD DEVIATIONS ACCEPTED OR
CORRECTED ON RECORD DRAWINGS.
D. ALL FIXTURES , DEVICES, & MILLWORK ARE EXISTING
U.O.N.
A. ALL ITEMS SHOWN ON REFLECTED CEILING PLAN
ARE EXISTING U.O.N.
B. EXISTING CEILING HEIGHT AT 9'-6"
WALL TYPE TAG
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
NOTE: PLUMBING LINES FOR NEW HAND
SINKS IN SUITE 206 ARE EXISTING AND
LOCATED WITHIN EXISTING WALLS. (REFER
TO PREVIOUS TENANT'S PERMIT PLANS
SHEET A-2 PERMIT #B06903223). SINKS AND
MILLWORK PROVIDED BY TENANT AND
CONNECTED BY PLUMBER.
NOTE: ALL NEW CEILING LIGHT FIXTURES AND
DEVICES ARE SHOWN FOR LOCATION AND
DESIGN INTENT ONLY. ALL ENGINEERING FOR
PERMITS, IF REQUIRED, IS OUTSIDE THE SCOPE
OF THESE DOCUMENTS.
NEW WALL TYPES
NEW PENDANT LIGHT
P
SCALE:
NEW RECESSED DOWN LIGHT
INTERIORALTERATIONFOR
PURESKINDERMATOLOGY
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
RODERICK JIMENEZ
5. SCALE:
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
FINISHES,FLOORING,ANDMATERIALSFOR
PURESKINDERMATOLOGYBUILDOUT
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
RODERICK JIMENEZ
SCALE:
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
FINISHES,FLOORING,ANDMATERIALSFOR
PURESKINDERMATOLOGYBUILDOUT
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
RODERICK JIMENEZ
SCALE:
SCALE:
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
PROPOSEDMILLWORKFOR
PURESKINDERMATOLOGY
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
SCALE:
SCALE:SCALE:
SCALE: SCALE:SCALE:
SCALE: SCALE:SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE:
SCALE:
SCALE:
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
PROPOSEDMILLWORKFOR
PURESKINDERMATOLOGY
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
SCALE:
SCALE:SCALE:
SCALE: SCALE:SCALE:
SCALE: SCALE:SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE:
SCALE: SCALE: SCALE:
SCALE:
SCALE:
SEAL AND SIGNATURE
MAY 8 2012
FL LIC ID#4952
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
FINISHES,FLOORING,ANDMATERIALSFOR
PURESKINDERMATOLOGYBUILDOUT
7932W.SANDLAKEROAD,SUITE205&206
ORLANDOFL
RODERICK JIMENEZ
6. Loft 55- Restaurant & Lounge
Responsabilities for Loft 55
- Site Analysis
- Programming
- Code Analysis
- Design Concepts
- Space Planning
- Reflected Ceiling Plan
- Construction Documents
- Site Visits
7. 2 X 2 FLUORESCENT FIXTURE
EXIT LIGHT W/ (2) EMERGENCY LIGHTING HEADS
AND BATTERY BACKUP
ACCOUSTICAL CEILING TILE AND GRID SYSTEM
@ 9'-0" A.F.F. , U.O.N.
ILLUMINATED EXIT LIGHT FIXTURE. SHADED
QUARTER(S) DENOTE ILLUMINATED FACE(S).
AIR DIFFUSER
A. CONTRACTOR SHALL COORDINATE THESE DRAWINGS WITH
THE ENGINEER'S DRAWINGS FOR LOCATION OF HVAC,
ELECTRICAL, EXIT LIGHTS/SIGNS, EMERGENCY LIGHTS,
SPRINKLERS, SPEAKERS, AND SIMILAR ITEMS. IF A
DISCREPENCY WITH QUANTITIES OR LOCATION EXISTS,
NOTIFY THE DESIGN TEAM OR GREATER QUANTITY
GOVERNS.
B. ALL AREAS/ROOMS ARE OPEN TO STRUCTURE ABOVE
UNLESS OTHERWISE NOTED.
C. REFERENCE ELECTRICAL DRAWINGS FOR LIGHT FIXTURE
SCHEDULE.
D. APPLY BLACK PAINT TO ALL EXPOSED CEIL. STRUCTURE,
DUCTWORK, DIFFUSERS, AND CONDUITS.
E. VINYL COATED CEILING TILE SHALL BE INSTALLED IN THE
KITCHEN.
DOWNLIGHTFIXTURE
EXHAUST FAN
RETURN
GYP. BRD. CEIL. @ 10'-0" A.F.F.
DANCE FLOOR TRACK LIGHT FIXTURE
(OWNER PROVIDED, VENDOR INSTALLED)
DANCE FLOOR DISCO BALL (OWNER PROVIDED.
VENDOR INSTALLED)
REFLECTED CEILING PLAN KEYNOTES
REFLECTED CEILING SYMBOLS
REFLECTED CEILING GENERAL NOTES
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
architect
looney,
keith
michael
SCALE:
SCALE:
SCALE:
SCALE:
DO NOT INSTALL CEILING GRID/TILE ABOVE AREA FOR
WALKIN COOLER. REFER TO MANUF. SPEC SHEET FOR
SPACE REQUIREMENTS.
1 X 4 LIGHT FIXTURE
1 X 4 STRIP LIGHT FIXTURE
1 X 4 FIXTURE ON EMERGENCY BALLAST
1 X 4 EMERGENCY AND NIGHT LIGHT FIXTURE
2 X 4 LIGHT FIXTURE
2 X 2 FLUORESCENT FIXTURE
EXIT LIGHT W/ (2) EMERGENCY LIGHTING HEADS
AND BATTERY BACKUP
ACCOUSTICAL CEILING TILE AND GRID SYSTEM
@ 9'-0" A.F.F. , U.O.N.
ILLUMINATED EXIT LIGHT FIXTURE. SHADED
QUARTER(S) DENOTE ILLUMINATED FACE(S).
AIR DIFFUSER
A. CONTRACTOR SHALL COORDINATE THESE DRAWINGS WITH
THE ENGINEER'S DRAWINGS FOR LOCATION OF HVAC,
ELECTRICAL, EXIT LIGHTS/SIGNS, EMERGENCY LIGHTS,
SPRINKLERS, SPEAKERS, AND SIMILAR ITEMS. IF A
DISCREPENCY WITH QUANTITIES OR LOCATION EXISTS,
NOTIFY THE DESIGN TEAM OR GREATER QUANTITY
GOVERNS.
B. ALL AREAS/ROOMS ARE OPEN TO STRUCTURE ABOVE
UNLESS OTHERWISE NOTED.
C. REFERENCE ELECTRICAL DRAWINGS FOR LIGHT FIXTURE
SCHEDULE.
D. APPLY BLACK PAINT TO ALL EXPOSED CEIL. STRUCTURE,
DUCTWORK, DIFFUSERS, AND CONDUITS.
E. VINYL COATED CEILING TILE SHALL BE INSTALLED IN THE
KITCHEN.
DOWNLIGHTFIXTURE
EXHAUST FAN
RETURN
GYP. BRD. CEIL. @ 10'-0" A.F.F.
DANCE FLOOR TRACK LIGHT FIXTURE
(OWNER PROVIDED, VENDOR INSTALLED)
DANCE FLOOR DISCO BALL (OWNER PROVIDED.
VENDOR INSTALLED)
REFLECTED CEILING PLAN KEYNOTES
REFLECTED CEILING SYMBOLS
REFLECTED CEILING GENERAL NOTES
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
architect
looney,
keith
michael
SCALE:
SCALE:
SCALE:
SCALE:
DO NOT INSTALL CEILING GRID/TILE ABOVE AREA FOR
WALKIN COOLER. REFER TO MANUF. SPEC SHEET FOR
SPACE REQUIREMENTS.
1 X 4 LIGHT FIXTURE
1 X 4 STRIP LIGHT FIXTURE
1 X 4 FIXTURE ON EMERGENCY BALLAST
1 X 4 EMERGENCY AND NIGHT LIGHT FIXTURE
2 X 4 LIGHT FIXTURE
PROPOSED FLOOR PLAN
AND SCHEDULES
N ACCORDANCE
ON AND ASTMD 2859
FLAMMABILITY OF
RING MATERIAL.
COMPLY WITH
UILDING CODE, 2007
ME SPREAD
LS OTHER THAN
UPANCY SHALL
.
RINKLERED
A
B
C
HANGES, PROVIDE
NS/EDGE GUARD AS
VED BY TENANT
NABLE FROM THE
NOWLEDGE OR
A SHAPE THAT IS
E TIGHT GRASPING,
O INSTALLATION.
. PHONE
ALIGN NEW WALL WHERE CEIL. HT. CHANGES
DASHED LINE INDICATES SOFFIT ABOVE. REFER TO REFLECTED
CEILING PLAN FOR HT AFF.
EXISTING SANITARY PIPE COLUMN TO REMAIN. BOX IN W/ 2-1/2"
MTL STUDS AND 5/8" GYP. BRD. TO 16'-0" HT.
NEW BAR BY MILLWORK CONTRACTOR (QTY 3.)
DASHED LINE INDICATES SUSPENDED GYP. BRD. CLOUD ABOVE
BAR. REFER TO REFLECTED CEILING PLAN FOR DIMENSIONS
AND HT AFF.
NEW PLATFORM @ 1'-9" AFF.
STAIRS INFO: 3 RISERS @ 7'" = 1'-9" AFF . 10" THREADS + 1
NOSING.
IN WOMENS RESTROOM AND KITCHEN, FURR EXISTING WALL
W/ 3-5/8" MTL. STUDS. @ 24" O.C. W/ 5/8" MOISTURE RESISTANT
GYP. BRD.
MILLWORK W/ 3 LAVATORIES AND MIRROR BY CONTRACTOR.
URINAL MOUNTED AT ADA ACCESSIBLE HT.
LOCKERS AND SHELVES BY MILLWORK CONTRACTOR.
NEW WATER HEATER
NEW UTILITY SINK. REFER TO PLUMBING DRAWINGS
NEW WASHER/DRYER.
NEW ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS
NEW TRANSFORMER. REFER TO ELECTRICAL DRAWINGS
RIOR WALLS W/ 2-1/2"
. UNLESS OTHERWISE
IN WALLS AS REQUIRED
TRACTOR. CONTRACTOR
WORK REQUIREMENTS
T FOR APPROVAL.
L BE WALL MOUNTED
FOR PLUMBING
TES
CEILING TILE
FLOOR PLAN KEYED NOTES
P: 407.301.2350 | E: info@therjcompany.com
SPACE PLANNING
INTERIOR DESIGN
TENANT BUILDOUTS
FL LIC IB26001017
THERJCOMPANY
12. A clean fresh feeling of sophistication,
luxury and glamour. A relaxing retreat
blended with modern elegance,
which creates pure tranquility.
Boutique Bed and Breakfast
Destination of Santa Catalina Island, California