Project No. Sheet No.
Scale Date Drawn
Drawing Title
Revision No.
Client
Project Title
AS SHOWN TM
0/0
PROPOSED NEW DWELLING
AND OUT-BUILDING
CONTRACTOR DRAWINGS
This drawing is the property of KNV Architects COPYRIGHT
is reserved by KNV Architects, and this drawing is issued
on the condition that it is not copied, reproduced, retained or
disclosed to any unauthorised person, either wholly or in part,
without the written consent of KNV Architects
ALL DIMENSIONS, DEPTHS OF EXCAVATIONS, NUMBER
OF STEPS, HEIGHTS OF PLINTHS AND LEVELS TO BE
CHECKED ON SITE, PRIOR TO COMMENCING OF ANY
BUILDING WORK.
DRAWINGS NOT TO BE SCALED. REFER TO DIMENSIONS
NOTES:
GLASS THICKNESS MAX. AREA m2
3mm
4mm
5mm
0.0 - 0.75m2
0.75 - 1.5m2
1.5 - 2.1m2
* SLIDING DOORS : SAFETY GLASS
* ALL ROOMS TO HAVE
CLEAR GLASS
* BATHROOMS & TOILETS TO
HAVE OBSCURE GLASS
TO USE
*
*
* BALLUSTRADES & HANDRAILS:
DRAINAGE NOTES:
* ALL DRAINAGE TO COMPLY WITH PART 'P' OF THE NATIONAL
BUILDING REGULATIONS
* I.E.'s TO ALL CONNECTIONS.
* R.E.'s AT CHANGE OF DIRECTION AND MARKED COVERES AT
GROUND LEVEL.
* DRAIN PIPES EXCEEDING 6m TO JUNCTIOIN TO HAVE OWN
100mm_ O.V.P.
* WASTE PIPES- 50mm_, SEWER PIPES- 100mm_
* WHERE DRAINAGE OCCURS UNDER FOUNDATIONS AND CONCRETE
FLOOR SLABS, PIPES TO BE ENCASED IN 100mm THICK CONCRETE
AND NOT DEVIATE FROM STRAIGHT LINE, WITH I.E.'s EITHER
SIDES.
* MINIMUM INVERT LEVEL OF DRAIN : 450mm
* 100mm DIA. V.P. AT HEAD OF DRAIN WITH 110mm AIRVALVE.
* WHERE ONE-PIPE SYSTEM IS APPLIED, ANTI-SYPHON VENT PIPES
TO BE 50mm_
* MIN. FALL OF DRAIN- 1:40, MAX. - 1:60
* WHERE FALL OF DRAIN EXCEEDS 1:10, BACK DROPS TO BE
PROVIDED TO ENSURE MAXIMUM FALL OF 1:10
* CONTRACTOR TO PROVIDE CERTIFICATE
* ALL NEW BUILDING WORK TO COMPLY TO THE NATIONAL
BUILDING REGULATIONS.
* ALL DIMENSIONS, DEPTHS OF EXCAVATIONS, NUMBER OF STEPS,
HEIGHTS OF PLINTHS AND LEVELS TO BE CHECKED ON SITE, PRIOR
TO COMMENCING OF ANY BUILDING WORK.
* READ FIGURED DIMENSIONS IN PREFERENCE TO SCALING.
* ALL FINISHES TO OWNER'S APPROVAL.
* OWNER TO BE RESPONSIBLE FOR ALL THE BUILDING WORK
ON THE PROPERTY.
* BRICKFORCE: (UNLESS OTHERWISE NOTED TO TAKE PREFERENCE,I.E NHBRC)
BUILT INTO WALLS 75mm AND 150mm "BRICKFORCE" IN THE
FOLLOWING POSITIONS:
a.) ONE LAYER IN EVERY FIFTH COURSE OF FOUNDATION WALLS & WALLS
b.) ONE COURSE UNDER WINDOW CILLS.
c.) TWO COURSES OVER WINDOW AND DOOR OPENINGS ABOVE LINTELS.
d.) TWO COURSES UNDER WALL PLATE.
* ALL GLAZING TO COMPLY WITH SECTION N OF THE
NATIONAL BUILDING REGULATIONS
* STORM WATER NOTE:
STORM WATERTO BE SURFACE CONTROLLED, IN THE DIRECTION AS
INDICATED ON PLAN, NOT TO BE DISPERSED OF IN CONCENTRATED VOLUMES,
AND TO BE DEPOSITED INTO THE MUNICIPAL SYSTEM TO THE SATSFACTION
OF THE LOCAL AUTHORITY.
- HEIGHT TO BE MINIMUM 1m ABOVE FINISHED FLOOR LEVEL
- NO DIVIDING SPROKETS TO BE FURTHER APARTTHAN 100mm
IN BALLUSTRADES
- BALLUSTRADE BOTTOM RAIL TO BE MAX. 100mm ABOVE
FINISHED FLOOR LEVEL
HOT WATER SERVICES:
* A MIN OF 50% BY VOLUME OF THE ANNUAL AVERAGE HOT WATER HEATING REQUIREMENT
SHALL BE PROVIDED BY MEANS OTHER THAN ELECTRICAL RESISTANCE HEATING, INCLUDING
BUT NOT LIMITED TO, SOLAR HEATING, HEAT PUMPS, HEAT RECOVERY FROM OTHER SYSTEMS
OR PROCESSES.
* THE SOLAR WATER HEATING SYSTEMS SHALL COMPLY WITH SANS 1307 & SANS 10106,
BASED ON THE THERMAL PERFORMANCE DETERMINED IN ACCORDANCE WITH THE
PROVISIONS OF SANS 6211-1 & SANS 6211-2. INSTALLATION SHALL COMPLY TO SANS 10254.
* HOT WATER USAGE SHOULD BE MINIMIZED AND THE SYSTEM MAINTAINED IN ACCORDANCE
WITH THE REQUIREMENTS GIVEN IN SANS 10252-1.
* GEYSER AND ALL EXPOSED PIPES TO AND FROM THE HOT WATER CYLINDERS AND
CENTRAL HEATING SYSTEMS SHALL BE INSULATED WITH INSULATION MATERIAL
WITH AN R-VALUE IN ACCORDANCE WITH SANS 10400.
TO COMPLY TO NBR. AS PER SPECIALIST SPECIFICATIONS.
* SPECIALIST TO PROVIDE CERTIFICATE
KNV
architects
MUGOVHANI
MAY 2017
2
B B
BIC
shr
Ø55
whb
Ø55
wc
Ø110
W1
W1 W1
W3
D2
D6
ce
ie
23039201151765230
6260
230 3420 230
3880
Guest Bedroom
Quarters
Bathroom
tiles
tiles
1m
concrete
apron
85
2615
2233
2125
3500
885
2720
2369
885
85
Dining RoomLiving Room
cornice
lintol lintol
cornice
counter
counter
dpc dpc85mm surface bed 85mm surface bed
250
pitch
concrete roof
tiles
concrete roof
tiles
250
pitch
ridge cap
Pergola
85 step
stone facing
stone facing
planter
Covd. ent
600 x 230mm
foundation
600 x 230mm
foundation
thickened slab
thickened slab
85mm surface bed
ngl ngl
uffl uffl
SECTION A-A
SCALE 1:50
ceiling ceiling
compacted earth filling
at layers not exceeding
150mm
hipped truss
to specialist
hipped truss
to specialistridge cap
170
pitch
2125
2720
D2
GUEST BREOOM
QUATERS
plaster and paint
lintol
cornice cornice
lintol
ceiling
150mm
min.
uffl
ngl
250
pitch
Ridge cap
concrete roof
tiles
85mm surface bed
compacted earth filling
at layers not exceeding
150mm
600 x 230mm
foundation
600 x 230mm
foundation
SECTION B-B
SCALE 1:50
hipped truss
to specialist
3500
885
2125
2125
2615
plaster and paint
plaster and paint plaster and paint
uffl uffl
garage +
entrance uffl
250
pitch
concrete roof
tiles
hipped truss
to specialistridge cap
250
pitch
concrete roof
tiles
250
pitch
COVD. ENT
hipped truss
to specialist
250
pitch
concrete roof
tiles hipped truss
to specialist
85 step
2125
2125
8851484
2369
1405
plaster and paint
plaster and paintplaster and paint
uffluffluffl
250
pitch
concrete roof
tiles
hipped truss
to specialist ridge cap
250
pitch
concrete roof
tiles
250
pitch
PERGOLA
hipped truss
to specialist
250
pitch
concrete roof
tileshipped truss
to specialist
85 stepngl ngl
2210
2125
8851484
2369
85
ufflgarage uffl
250
pitch
concrete roof
tiles
hipped truss
to specialist
ridge cap
250
pitch
concrete roof
tiles
250
pitch
hipped truss
to specialist
ngl ngl
uffl
250
pitch
concrete roof tiles
plaster and paint plaster and paintplaster and paint
2125
uffl garage uffl
250
pitch
concrete roof
tiles
hipped truss
to specialist
ridge cap
250
pitch
concrete roof
tiles
250
pitch
hipped truss
to specialist
nglngl
uffl
250
pitch
concrete roof tiles
plaster and paintplaster and paint plaster and paint
ELEVATION 1
SCALE 1:100
ELEVATION 2
SCALE 1:100
ELEVATION 3
SCALE 1:100
ELEVATION 4
SCALE 1:100
O/B GROUND FLOOR
SCALE 1:50