Capalli Botha - Sheet - Pg_01 - Construction Plans03
BD 1232 rev F -03-01 Building
1. 2000mm
fire escape
2000mm
2000mm
fire escape
SCISSOR
LIFT
0000
datum
floor level
BIN STORE AREA
upto
mezz floor
1 2 3 4
DELIVERIES
up
up
up
up
up
up
up up
up
up
up
up
up
up
up up
up
up
up
up
up
up
1 2 3 4 5 6 7 8 9 10 11
121314151617
amps
ALLEY WAY TO
BOURNE STREET CARPARK
FlatEntrance
1
&
2
2220clear
up
up
E.D.A. 770m2
full height wall
Service and
Dump Station
UP
(NOACCESS)
MOTOR
ROOM
HOIST/
LIFT
7092
2965
1:12 ramp
+525 existing ramp
+1135m
CoverLevel
55.25
InvertLevel
53.36
Inspection
Chamber
MALE TOILETS
FEMALE TOILETS
cleaners
cpbd
store
cpbd
chemical store
MAIN LOBBY
OFFICE
CELLAR
wine gallery
USB=1.99
55.29
54.98
53.92
53.87
55.35
SERVICE STATION
MAIN RESTAURANT SEATING
STREET MARKET
glass
wash
54.98
54.98
up
55.35
Seating 108
RAISED SEATING AREA
covered delivery ramp
01
02
03
04
05
06
07
08
+108
+154
+154
+154
+154
+154
+153
+152
01
02
03
04
05
06
07
08
+108
+154
+154
+154
+154
+154
+153
+152
up
01+160
02+160
03+160
01+160
02+160
03+160
exterior stairs 01
stairs 01
stairs 03
up
stairs 05
stairs 06
exterior stairs 02
Raised
Plinth
SCISSOR
LIFT
upto
mezz floor
1 2 3 4
6000
5271
3906
6897
Freezer 30m2 Fridge 25m2
stairs 07
stairs 07
up
01+160
02+160
03+160
SERVER
DISABLED
REVISION DATE ITEM
CONSTRUCTION
DATE
July 2012
COSMO, Derby
DRAWN
PROJECT
PROJECT
TITLE
NUMBER
shown
SCALE
REVISION
CHECKED
INFORMATION ONLY
APPLICATION FOR LOCAL AUTHORITY
TENDER
TO THE CURRENT HEALTH AND SAFETY AT WORKS CONDITIONS AND LOCAL
12. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE OTHER RELEVANT
11. IN THE EVENT THAT DRAWING INFORMATION IS NOT THE SAME, AND IF THE
AND ARE NOT TO BE SCALED FROM THE THE DRAWINGS.
7. ALL FINISHES ARE TO BE CARRIED OUT TO A HIGH STANDARD.
8. ANY DIMENSIONS ARE TO BE TAKEN FROM THE SETTING OUT PLAN ONLY
THE PROPOSED PLAN IS TO BE READ AS CORRECT.
THAT ANY BUILDING IS CARRIED OUT UNDER THE LOCAL AUTHORITY
13. COPYRIGHT OF BLENHEIM DESIGN. NOT TO BE REPRODUCED
DESIGNER AND OR SUPERVISING OFFICER ARE UNAVAILABLE FOR COMMENT,
AND CONSTRUCTION DETAILS AND OFFER ALTERNATIVES TO THE DESIGNER
10. THE CONTRACTOR IS TO CHECK AND APPRAISE ALL DESIGN SHOP FITTING
9. IT IS THE CONTRACTORS RESPONSIBILITY TO UNDER TAKE AND ENSURE
FOR APPROVAL.
CONSULTANTS DRAWINGS.
AUTHORITY REGULATIONS.
REQUIREMENTS.
MANUFACTURERS RECOMMENDATIONS.
DETAILS ARE REQUIRED TO BE APPROVED BY BLENHEIM DESIGN PRIOR TO
BEFORE PROCEEDING WITH ANY WORK.
ARE TO BE CLASS 1 OR EQUIVALENT).
6. CONTRACTOR TO PROVIDE A WORKING ENVIRONMENT WHICH CONFORMS
5. ALL SPECIFIED ITEMS ARE TO BE INSTALLED IN ACCORDANCE WITH THE
4. ALL REQUESTED DRAWINGS SHOWING FIXINGS AND CONSTRUCTION
AND SPECIFICATIONS AND REPORT ANY DISCREPANCIES TO BLENHEIM DESIGN
2. CONTRACTOR MUST VERIFY ALL SITE DIMENSIONS, DRAWINGS, DETAILS
REGULATIONS IN THE APPLICABLE COUNTRY (IN A RESTAURANT ALL FINISHES
1. ALL FINISHES ARE TO CONFORM TO THE REQUIRED CURRENT BUILDING
COMMENCEMENT OF WORK.
GENERAL NOTES
Builders works drawing
MM
03-01BD 1232
BLENHEIM
DESIGN...
6 St Peters Place
Brighton
BN1 4SA
t: 01273 380001
info@blenheimdesign.com
one layer of 12.5 wallboard each side of
70mm gyproc studs to provide 1 /2 hr fire
resistance partition duty: medium to BS 5234
parts 1 & 2 1992. to be installed from structural
floor to slab.
Existing structure
ALL 1 & 1/2 HR FIRE RESISTING WALLS TO RUN FULL HEIGHT AND
SHOULD BE SUITABLY FIRE STOPPED TO MAINTAIN 1/2 & 1 HR
FIRE INTEGRITY.
CP
1/2F
L
FG
SD
SI
HD
FE
VP
B
CP
1/2F
L
FG
PP
SD
EL
SI
HD
FE
VP
SC
CO
W
CO
W
STANDARDS REQUIRED TO BE ACHIEVED IN RESPECT OF FIRE & SAFETY MATTERS.
1 DOORS AND PARTITIONS REQUIRED TO BE FIRE RESISTING ARE TO BE IN ACCORDANCE WITH BRITISH
STANDARD BS 476 1972 AS AMENDED.
2 FIRE RESISTING DOORS REQUIRED TO RESIST THE PASSAGE OF SMOKE AT AMBIENT TEMPERATURE
CONDITIONS SHOULD, UNLESS TESTED IN ACCORDANCE WITH BS 476 SECTION 31.1 1983
3 THE FIRE ALARM SYSTEM TO COMPLY WITH BRITISH STANDARDS BS 5839 PART 1 2002. THE ATTENTION
OF THE DESIGN INSTALLING ENGINEER SHOULD BE DRAWN TO PARAGRAPH 4.3 (CONSULTATION RECORDS)
OF BS 5839 PART 1 2002 WHICH REQUIRES CONSULTATION WITH THE FIRE AUTHORITY.
4 THE EMERGENCY LIGHTING INSTALLATION IS TO COMPLY WITH BRITISH STANDARD BS 5266 PART 1 1999
THE ATTENTION OF THE DESIGN INSTALLING ENGINEER SHOULD BE DRAWN TO PARAGRAPH 3.1
(CONSULTATION AND RECORDS) OF BS 5266 PART 1 1999. WHICH REQUIRES CONSULTATION WITH THE
FIRE AUTHORITY.
5 FIRE SAFETY RELATED SIGNS AND NOTICES ARE TO CONFORM TO CURRENT BRITISH STANDARDS.
6 ILLUMINATED 'EXIT' SIGNS ARE TO CONFORM TO BS 5499 PARTS 1, 3 & 4.
7 FIRE FIGHTING EQUIPMENT IS TO COMPLY WITH BS EN3 1-6, BS 7863 (1996), BS 7867 (1997) AND BS 5306
8 UPHOLSTERED SEATING FURNITURE MUST SATISFY, AS A MINIMUM STANDARD, IGNITION SOURCE O
(CIGARETTE TEST) AND CRIB IGNITION SOURCE 5 AS SPECIFIED IN BS 5852 1990. 'METHODS OF TEST FOR
ASSESSMENT OF THE INGITABILITY OF UPHOLSTERED SEATING BY SMOLDERING AND FLAMING IGNITION
IF IN ORDER TO SECURE COMPLIANCE WITH THE ABOVE STANDARDS WITH THE FABRIC SUBMITTED FOR
TEST HAS BEEN TREATED BEFOREHAND WITH A FIRE RETARDANT PRODUCT, THE TESTING LABORATORY
MUST BE INSTRUCTED TO SUBJECT HE SAMPLES TO BE TREATED TO A WATER SOAK TEST. IN ACCORDANCE
WITH BS 5651 1989 PARAGRAPH 3, BEFORE THE BS 5852 TESTS ARE CARRIED OUT. A COPY OF THE
LABORATORY TEST REPORT FROM AN ACCREDITED TESTING LABORATORY IDENTIFYING COMPLIANCE OF
THE FURNISHING COMPOSITE WITH THE ABOVE MENTIONED BRITISH STANDARDS MUST BE FORWARDED
TO THE LOCAL AUTHORITY BEFORE INSTALLATION AND CONFIRMATION THAT THE FURNISHING SPECIFIED
IN THIS CERTIFICATE HAVE BEEN INSTALLED IN THE PREMISES.
9 CURTAINS AND OTHER TEXTILE HANGINGS MUST BE INHERENTLY FLAME RETARDANT OR BE TREATED
WITH A DURABLE FLAME FLAME RETARDANT. THEY MUST BE CAPABLE OF COMPLYING WITH 'TYPE B'
PERFORMANCE REQUIREMENTS OF BS 5857 PART 2 1980 - 'SPECIFICATION FOR FABRICS FOR CURTAIN AND
DRAPES - FLAMMABILITY REQUIREMENTS'
10 ARTIFICIAL FOLIAGE AND OTHER DECORATIVE EFFECTS ARE TO BE FIRE RETARDET TO THE
SATISFACTION OF THE FIRE AUTHORITY.
11 LININGS AND SURFACE FINISHES OF WALLS AND CEILING SHOULD HAVE SURFACE SPREAD OF FLAME
RATING AS DEFINED IN THE BUILDING REGULATIONS 1991.
12. CERTIFICATES OF INSTALLATION TEST WILL BE REQUIRED IN RESPECT OF ITEMS NUMBER 3,4,6,8 AND 9
ABOVE AND MAY BE REQUIRED FOR ITEM 2.
NOTE:
ANY REFERENCE TO A BRITISH STANDARD (BS) SHOULD TAKEN TO INCLUDE THE EQUIVALENT EUROPEAN
STANDARD IF RELEVANT AND THE LATEST VERSION IN THE SPEC MENTIONED IS SUPERSEDED.
Restaurant seated and queuing customers
TOTAL NUMBER OF OCCUPANCY + 30 STAFF
FEMALE/DISABLED
Ambulant Disabled customers:
The Scheme has been designed to comply with Part M of the building
Toilet accomodation
The toilet accomodation is based upon BS 6465 Part 1 2006, Sanitary
instalations. Table 9 - Full on license. Ratio of male to female being 50% each.
Clear Means of escape width required for 350 persons
WHB's
1750mm
Urinals WC's
N/A 7 7
OCCUPANCY LEVELS
Area
Means of Escape Capacity for COSMO RESTAURANT
Ocupancy rates are based upon current Building Regulations
Whole demise in total 1645 sq m
Total
Restaurant and public toilet area
Staff and kitchen area
Exterior seating area
996 sq m
649 sq m
N/A
350
N/A
Class B Standard ie. 12mm laminated or toughened
All front of house glazing to comply with BS 6206 1981
GLAZING
MALE 4 2 4
External seating area
320
Two layer of 12.5 wallboard each side of
70mm gyproc studs to provide 1 hr fire
resistance. To be installed from structural
floor to slab.
100mm thick Thermalite party wall from
Hanson use with thin layer mortar, with
12.5mm walboard on inside. Installed to BS
5628: Parts 1
NEW COCRETE
EXTERIOR RAMP,
COMPLETE WITH THE
HANDRAIL
EXISTING PARTITION
TO BE DEMOLISHED
TO STRUCTURAL
ENGINEERS DETAILS
CREATE A NEW
WALL OPENING
TO STR. ENG.
DETAILS
One fully disabled toilet is situated on the ground floor.
EXISTING STAIRS
ARE TO BE
DEMOLISHED TO
CREATE LEVELED
FLOOR AREA
THROUGHOUT
EXISTING STAGE
STAIRS ARE TO BE
REMOVED
EXISTING PARTITION
TO BE DEMOLISHED
PP
PP
PP
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
B
COCO
WW
CPCP
CPCP
CPCP
CPCP
CPCP
CPCP
CPCP
B
COCO
WW
B
COCO
WW
B
COCO
WW
COCO
WW
COCO
WW
COCO
WW
COCO
WW
COCO
WW
SISI
SDSDEL
HDEL HDEL
HDEL
HDEL
HDEL
HDEL
HDEL
HDEL
HDEL
HDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL SDSDEL
SDSDEL
SDSDEL
SDSDEL SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSD
SDEL
SDSDEL
SISI
SISI
CREATE A NEW
WALL OPENING
TO STR. ENG.
DETAILS
SDSDEL
SDSDELSDSDEL
SDSDEL
SDSDEL
SDSDEL
SDSDEL
HDEL
SDSDEL
SDSDELSDSDEL
SDSDEL
SDSDEL
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
HDEL
SDSDEL
SDSDEL
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F 1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F 1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
1/2F
1/2F
1/2F1/2F
1/2F1/2F
1/2F1/2F
LL
LL
SC
1/2F1/2F
L
L
L
FGFG
FGFG
FGFG
FGFG
FGFG FGFG
FG
FG
FG
FG
FG
FG
SISI
FEFE
FEFE
FEFE
FEFE
FEFE
FG
FG
FG
FG
FG
FEFE
PP SISI
F
A 19-07-12 SUSPENDED FLOOR OMITTED, FEW WALLS AMENDED
B 01-08-12 Some walls moved to allow for the new kitchen layout
SDSDEL
SDSDEL
ALL STRUCTURAL COLUMNS ARE TO BE PREPARED TO RECEIVE 1
HR FR INTUMISCENT PAINT
AREA BETWEEN THE FIRST AND GROUND FLOOR IS TO BE 1 HR FR
RESISTANT, ONE LAYER OF 12.7MM FIRE SHIELD C GYPSUM
APPLYED TO 50X100MM WOOD JOISTS WITH 5D NAILS 1-5/8
LONG. 13MM WOOD STRUCTURAL PANEL APPLYED AT RIGHT
ANGLE WITH 8 D NAILS, READY TO RECEIVE FINAL FLOOR FINISH
AMBULANCE DISABLED
STAIRS, 160MM CLOSED
RISERS AND 250MM
GOING COMPLETE WITH
CONTRASTING NOSING, ref
GA1403(S) Gooding
aluminium
1696
1372
1723
1772
1772
1474
1700
EL
AMBULANCE DISABLED
STAIRS, 160MM CLOSED
RISERS AND 250MM
GOING COMPLETE WITH
CONTRASTING NOSING, ref
GA1403(S) Gooding
aluminium AMBULANCE DISABLED
STAIRS, 160MM CLOSED
RISERS AND 250MM
GOING COMPLETE WITH
CONTRASTING NOSING, ref
GA1403(S) Gooding
aluminium
C 08-08-12 server room added
D 17-08-12 Notes added to reflect building regulation comments
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
VPVP
E 23-08-12 Door at the stage area changed
F 10-09-12 Disabled toilet changed + portable ramp added
SDSDEL
SDEL
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCEDBYANAUTODESKEDUCATIONALPRODUCT
PRODUCEDBYANAUTODESKEDUCATIONALPRODUCT
PRODUCEDBYANAUTODESKEDUCATIONALPRODUCT