opus automazione S.p.A manufactures standard and customized test benches, which satisfy the test specifications requirements of the most important carmakers.
opus has been producing for twenty years test benches for a wide range of products and other kind of test benches for example exhaust gases analysis both diesel and petrol engines.
A standard test benches overview is shown in this catalogue.
White paper provides description of function and application of current to pneumatic (I/P) transducers, along with operational diagrams and recommended practices.
opus automazione S.p.A manufactures standard and customized test benches, which satisfy the test specifications requirements of the most important carmakers.
opus has been producing for twenty years test benches for a wide range of products and other kind of test benches for example exhaust gases analysis both diesel and petrol engines.
A standard test benches overview is shown in this catalogue.
White paper provides description of function and application of current to pneumatic (I/P) transducers, along with operational diagrams and recommended practices.
The Oxymitter™ 4000 In Situ Oxygen Transmitter is the world's first in situ, zirconium oxide-based oxygen transmitter for flue gas measurement with an explosion-proof rating. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency.
In the first half of this year I was asked to investigate the potential passive air flow on two odour skid's. It was thought that the current media in the tank's could be changed out with more economical product. Before this could be determined the passive flows needed to be checked before and after the extraction fan.
Vertical multistage fire pump catalogue-60HZAndy Chen
Vertical multistage pump is always used for fire fighting as jockey pump, for more details, pls check http://www.firepump.cc/product/XBD-CDL-jockey-pump.html
Industry needs muscle to control process valves, dampers and feed mechanisms accurately and in response to a demand signal. Emerson’s Rosemount Analytical pneumatic power positioners have been satisfying these exacting control requirements for many years in countless applications – from steel mills to refineries – where positioning speed and accuracy are taken for granted.
Fire Pump Controller Interactive ParametersJames S Nasby
www.Lucky-Bet.site => Bet on Sports - 50% Deposit Bonus
www.Lucky-Bet.site/casino => Online Casino - 5000$ Welcome Bonus
www.Lucky-Bet.site/lotto247 => Lotto247 - Win Big, Live Free
www.Lucky-Bet.site/eurobet => Best European Bookmaker
www.earnperhit.com/essay => Professional academic writing
Fire Pump Controller Interactive Parameters affecting Diesel Driven and Electric Motor Driven Fire Pump Controllers and Installations.
www.Lucky-Bet.site => Bet on Sports - 50% Deposit Bonus
www.Lucky-Bet.site/casino => Online Casino - 5000$ Welcome Bonus
www.Lucky-Bet.site/lotto247 => Lotto247 - Win Big, Live Free
www.Lucky-Bet.site/eurobet => Best European Bookmaker
www.earnperhit.com/essay => Professional academic writing
Key Characteristics and Requirements of Diesel Fire Pump Engines
The Oxymitter™ 4000 In Situ Oxygen Transmitter is the world's first in situ, zirconium oxide-based oxygen transmitter for flue gas measurement with an explosion-proof rating. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency.
In the first half of this year I was asked to investigate the potential passive air flow on two odour skid's. It was thought that the current media in the tank's could be changed out with more economical product. Before this could be determined the passive flows needed to be checked before and after the extraction fan.
Vertical multistage fire pump catalogue-60HZAndy Chen
Vertical multistage pump is always used for fire fighting as jockey pump, for more details, pls check http://www.firepump.cc/product/XBD-CDL-jockey-pump.html
Industry needs muscle to control process valves, dampers and feed mechanisms accurately and in response to a demand signal. Emerson’s Rosemount Analytical pneumatic power positioners have been satisfying these exacting control requirements for many years in countless applications – from steel mills to refineries – where positioning speed and accuracy are taken for granted.
Fire Pump Controller Interactive ParametersJames S Nasby
www.Lucky-Bet.site => Bet on Sports - 50% Deposit Bonus
www.Lucky-Bet.site/casino => Online Casino - 5000$ Welcome Bonus
www.Lucky-Bet.site/lotto247 => Lotto247 - Win Big, Live Free
www.Lucky-Bet.site/eurobet => Best European Bookmaker
www.earnperhit.com/essay => Professional academic writing
Fire Pump Controller Interactive Parameters affecting Diesel Driven and Electric Motor Driven Fire Pump Controllers and Installations.
www.Lucky-Bet.site => Bet on Sports - 50% Deposit Bonus
www.Lucky-Bet.site/casino => Online Casino - 5000$ Welcome Bonus
www.Lucky-Bet.site/lotto247 => Lotto247 - Win Big, Live Free
www.Lucky-Bet.site/eurobet => Best European Bookmaker
www.earnperhit.com/essay => Professional academic writing
Key Characteristics and Requirements of Diesel Fire Pump Engines
ICS Heat Pump Technology Product Guide Feb 2011markpartridge
Brochure containing descriptions and specifications of the DeLonghi Climaveneta range of commercial and domestic heat pumps and related products/technologies.
Presstrade Corporate Presentation September 2009markpartridge
Presentation overviewing the services and capabilities of Presstrade GmbH, market leaders in the supply of used and refurbished forging and related equipment.
EL-FLOW Prestige is the next generation of Bronkhorst Mass Flow Meters / Controllers for gases. Nearly all core components have been redesigned and many improvements and innovations have been incorporated. With this new series Bronkhorst introduced the “Differential Temperature Balancing” technology, ensuring a superb sensor stability.
New catalog of telematic products from Mechatronics. Onboard weighing and wireless cold chain monitoring were added to well-known remote fuel monitoring solutions.
New catalog of telematic products from Mechatronics. Onboard weighing and wireless cold chain monitoring were added to well-known remote fuel monitoring solutions as well as other products
What is a flowmeter ?
Simply a device that can monitor and measure the actual amount of ‘product’ being sent through it. Typically flowmeters in industry are used for monitoring use of water, chemicals, ingredients, etc.
التحكم الأمثل فى أنظمة تعزيز الضغط GS
⚪⚪⚪⚪⚪⚪⚪⚪
تتضمن هذه الأنظمة من معززات الضغط حتى ثلاثة مضخات كهربائية وهى معززات ثابتة السرعة ومن خلال هذه الفئة يتم التحكم بالمضخات من خلال وحدة التحكم الرئيسية إضافة إلى وحدة تحكم إضافية وتأتى بشاشة خارجية لإظهار حالة العملية التشغيليةSM30
أولا بأول و سير عمل المضخات
وتضمن هذه الفئة سير العملية التشغيلية حتى فى حال إحدى المضخات للصيانة, تستخدم فى تطبيقات الصرف الصحى و إمدادات المياه كذلك فى أنظمة المبانى التجارية مثل المدارس, المستشفيات, الفنادق إضافة إلى التطبيقات الصناعية
للمزيد
http://rheoserve.com/booster_sets.html
Toshniwal - Thermal mass flow meters and controllerSangeethaS99
THERMAL MASS FLOW METERS AND CONTROLLER
The range of Thermal Mass Flow Meters from Bronkhorst address high accuracy in low flow rate scenarios like those seen in laboratory and Pilot plant usages. With a housing designed for laboratory and clean processing conditions, the instruments are truly unique in their capability to measure and control flow ranges between 0,014…0,7 mln/min and 8…1670 ln/min with pressure rating between vacuum and 400 bar – all in one range of instruments.
FEATURES
Rangeability in digital mode up to 1:150
High accuracy (standard 0,5% Rd plus 0,1% FS)
Pressure ratings 64 / 100 bar
Highly resistant to mechanical shocks and pressure fluctuations
Large range of Input/output options to choose from
Extremely fast and dynamic response
User configurable control characteristics
Applications
Analytical/environmental equipment
Gas flow monitoring in food, chemical and petrochemical industries
Gas consumption measurement in gas distribution systems for internal accounting purposes
Detection of gas leakage through objects
Semiconductor manufacturing
Surface treatment installations
Improving Energy Efficiency of Pumps and Fanseecfncci
Pumps and Fans are energy consuming equipment that can be found in almost all Industries. Therefore, it is important to check if they are running efficiently. This presentation give an overview about energy saving opportunities in pump and fan equipment. It was prepared in the context of energy auditor training in Nepal in the context of GIZ/NEEP programme. For further information go to EEC webpage: http://eec-fncci.org/
1. SEMTECH®
EFM-HS
High Speed Exhaust Flow Meter
Sensors’ High Speed Exhaust Flow Meter, the SEMTECH EFM-HS, adds
exciting capabilities and features to the product line. With a sampling rate
of up to 2500 Hz and four, dual stage differential pressure transducers, the
EFM-HS accurately measures every forward and reverse flow pulsation from
idle to maximum flow rate, and properly accounts for these pulsations in
the exhaust flow determination. This is a tremendous advantage over low
speed exhaust flowmeters which are susceptible to measurement error
from high frequency pulsations. The EFM-HS also offers a long list of other
performance enhancements and convenience features that set it apart
from the competition.
Mass flow rate accuracy and linearity of the SEMTECH EFM-HS exceeds the
US and European performance standards over a 50:1 turndown ratio. The
EFM-HS can be used to measure exhaust flow rate from both spark and
compression ignition engines, as a stand-alone device, or in conjunction
with the emissions measurements of the SEMTECH-DS or other gas
analyzers, to compute real-time mass emissions.
Emissions
Measurement
Solutions
2. 2
SEMTECH EFM-HS
High Speed Exhaust Flow Meter
Optional Configurations
High Speed Data Acquisition: Data output rate of 500 Hz is
available.
Stand-AloneConfiguration:SENSORTech-EFMHS application
enables system operation from a Windows environment.
Dual Channel Configuration: A second channel with a
full set of transducers can be added to the system in the
same electronics module. This is useful for measuring
a dual exhaust system, exhaust and EGR simultaneous
measurement, or detecting undeveloped flow conditions.
Customized Interface: Sensors can develop a customized
device driver to interface with various host systems.
System Features and Benefits
High Speed Sampling: The EFM-HS internally samples the differential
pressure channels at up to 2500 Hz, accounting for every pressure
pulse from an engine, from idle to maximum rpm. Standard output
rate is 5 Hz.
Embedded Calibration: Calibration coefficients embedded in the flow
tube electronics are automatically recognized on connection, enabling
multiple tubes to be used with one control module.
Multiple Tube Sizes: Eight flow tube sizes accommodate engines from
less than 0.8L displacement up to 24L.
Back Purge: A software controlled back purge pump is included in
the flow tube assembly along with solenoids that route high pressure
air backward through the pitot tube, purging contaminants and any
condensation in the pressure lines. No dismantling is required.
Auto Zero: With a single software command, internal solenoids open
the pressure sensors to ambient air, allowing fast and easy zeroing
while the engine is still operating.
Weatherproof Construction: The unit can be used off-road and in
other harsh environments. All components are weatherproof to IP54
(NEMA 3) standards.
Heated Components: The averaging pitot tube and pressure lines are
heated at the flow tube assembly in order to prevent condensation
and freezing in cold weather. The differential pressure sensors are
housed in a temperature controlled manifold in the control module
for added stability.
Sample Screen from SENSOR Tech-EFMHS
3. 3
SEMTECH EFM-HS
High Speed Exhaust Flow Meter
The Technology
Operating under the Bernoulli principle, the
SEMTECH EFM-HS uses four high performance,
dual-stage, differential pressure transducers,
sampling continuously at up to 2500 Hz,
measuring every pressure pulse from an engine.
The sensors are housed in a heated manifold,
eliminating thermal drift. The eight combined
differentialpressurerangesspannearlyfiveorders
of magnitude, allowing accurate measurements
over a wide range of flow rates. The smallest
transducer range is 0.025 kPa with a resolution of
5x10-5
kPa, while the highest range is 16.5 kPa.
A proprietary algorithm computes a spline fit of the
eight high speed differential pressure signals, and
calculates a running square-root average that is used
to determine output flow rates at 5 Hz (500 Hz with
the high speed option). The high speed sampling
and symmetrical design of the averaging pitot tube
provides the EFM-HS with the ability to accurately
measure reverse flow due to engine pulsations, and
to properly account for this phenomenon in the
average flow rate determination.
4. Sensors, Inc. • 6812 State Rd. • Saline, Michigan 48176 • PH:(734) 429-2100 • FX:(734) 429-4080 • www.sensors-inc.com
Sensors Europe GmbH • Feldheider Str. 60 • 40699 Erkrath • Germany • PH: +49 (0) 2104-14188-0 • FX: +49 (0) 2104-14188-14
SEMTECH EFM-HS Available Sizes and Flow Rates
Recommended Application: Engine Size (L) & Type
Gas
Diesel
< 1†
< 0.8
< 2†
< 1.5
< 2
< 1.5
2 - 5
1.5 - 4
> 5
4 - 6
-
6 - 12
-
12 - 18
-
> 18
Flow Tube Outer Diameter
in
mm
1
25
1.5
38
2
51
2.5
64
3
76
4
102
5
127
6
152
Flow Tube Length (Length including extension)
in
mm
20 (26)
508 (660)
20 (26)
508 (660)
20 (26)
508 (660)
25 (32.5)
635 (825)
25 (34)
635 (864)
25 (37)
635 (940)
30 (45)
762 (1143)
36 (54)
914 (1372)
Backpressure Flow rate at 200°C, SCFM (m3
/min)
10” H2
0
2.5 kPa
67
(1.9)
109
(3.1)
175
(4.9)
425
(12.0)
600
(17.0)
1100
(31.2)
1700
(48.1)
2380
(67.3)
15” H2
0
3.75 kPa
83
(2.4)
146
(4.1)
215
(6.1)
550
(15.6)
775
(22.0)
1350
(38.2)
2100
(59.5)
2940
(83.3)
Backpressure Flow rate at 400°C, SCFM (m3
/min)
10” H2
O
2.5 kPa
56
(1.6)
91
(2.6)
147
(4.2)
356
(10.0)
503
(14.3)
922
(26.2)
1425
(40.3)
1995
(56.4)
15” H2
O
3.75 kPa
69.6
(2.0)
122
(3.5)
180
(5.1)
461
(13.1)
649
(18.4)
1132
(32.0)
1760
(49.9)
2465
(69.8)
†
Non-Turbo
NOTE: Specifications are subject to change without no-
tice. While due caution has been exercised in the produc-
tion of this document, possible errors and omissions can
occur.
R 05/10
4
SEMTECH EFM-HS
High Speed Exhaust Flow Meter
Exhaust temperature range: -5 to 700°C standard construction (higher temperature capability available
upon request)
Exhaust temperature accuracy: ± 1% of reading or ± 2°C, whichever is greater
Flow measurement linearity: < 1.0% of full scale
Exceeds 1065 Subpart D and ISO 16183 standards
Flow measurement accuracy: ± 2% of reading or ± 0.5% of full scale, whichever is greater
Warm up time: < 5 minutes at 20°C ambient
System response time: < 2 ms
Data rate: 5 Hz standard
High Speed option data rate: 500 Hz (100 Hz display rate)
Resolution: 0.1 SCFM
Power requirements: 12VDC , 30W; 110VAC
Communications: RS 232
Control module dimensions: 36cm x 18cm x 10cm (LxDxW)
Control module weight: 4kg (9 lbs)
Length*
Diameter*
69.0mm
381.0mm
49.0mm
*see chart above.
NOTE: Accurate measurments require adequate straight
pipe length prior to the exhaust entering the measuring
pitot. This is ensured with our tube extension kits, refer-