Skip to main content
COMMERCIAL HEAT PUMPS


RESIDENTIAL HEAT PUMPS
2




    ICS HEAT PUMP TECHNOLOGY
    DeLonghi-Climaveneta
    PARTNERSHIP
    The ICS Group has a strong historical
    relationship with DeLonghi-Climaveneta,
    Europe’s leading manufacturer of
    refrigeration based temperature control
    equipment.
    Having built their first Heat Pump units in 1979, DeLonghi-Climaveneta can certainly stake
    their claim as being one of the most innovative and forward thinking manufacturers of air
    source heat pumps and ground source/geothermal heat pump over the last thirty years. This
    well established historical relationship between the ICS Group and DeLonghi-Climaveneta
    has formed the basis for ICS Heat Pump Technology being selected by DeLonghi-Climaveneta
    to exclusively provide the DeLonghi Professional range of residential heat pumps and
    Climaveneta commercial heat pumps throughout the UK and Ireland.
3




CONTENTS
  ICS DELONGHI-CLIMAVENETA PARTNERSHIP                   pg 2
  DELONGHI-CLIMAVENETA                                   pg 4-5
  ICS HEAT PUMP TECHNOLOGY                               pg 6
  ICS APPROVED PARTNER PROGRAMME                         pg 7
  RESIDENTIAL CASE STUDIES                               pg 8
  COMMERCIAL CASE STUDIES                                pg 9
  AIR SOURCE HEAT PUMPS INTRODUCTION                     pg 10-11
  MEDIUM TEMPERATURE HEAT PUMPS                          pg 12-19
  •   Bran H Medium Temperature Air Source Heat Pump     pg 12-13
  •   AWR MTD Medium Temperature Air Source Heat Pump    pg 14-15
  •   DHW Twin Medium Temperature Air Source Heat Pump   pg 16-17
  •   MICS-N Medium Temperature Air Source Heat Pump     pg 18-19
  HIGH TEMPERATURE HEAT PUMPS                            pg 20-27
  •   i-KI High Temperature Air Source Heat Pump         pg 20-21
  •   HT 65ºC High Temperature Air Source Heat Pump      pg 22-23
  •   i-NRG High Temperature Air Source Heat Pump        pg 24-25
  •   Prana HT High Temperature Air Source Heat Pump     pg 26-27
  GROUND SOURCE & GEOTHERMAL HEAT PUMPS INTRODUCTION     pg 28-29
  •   BWR MTD Ground Source & Geothermal Heat Pump       pg 30-31
  •   DHW Twin Ground Source & Geothermal Heat Pump      pg 32-33
  •   Prana MTD Ground Source & Geothermal Heat Pump     pg 34-35
  •   Prana DHW Ground Source & Geothermal Heat Pump     pg 36-37
  BUFFER TANKS                                           pg 38
  DHW CYLINDERS                                          pg 39
  FAN COILS & HYDRONICS                                  pg 40-41
  APPLICATION & SPECIFICATION SUPPORT                    pg 42
  ACCESSORIES                                            pg 42
  TECHNICAL SERVICE SUPPORT                              pg 43
4




    DeLonghi-Climaveneta
                     PRODUCT INNOVATION
    RESEARCH & DEVELOPMENT
          HEAT PUMP FOCUS
          40 YEARS EXPERIENCE


    DeLonghi-Climaveneta is the leading,
    refrigeration manufacturer in Europe.The
    company has a worldwide reputation for
    product reliability and quality with over 35
    years of market leading experience. The
    company has 5 key manufacturing
    facilities occupying some 52,000 square
    meters of production space. The
    company achieves a turnover level in
    excess of 210 million euros worldwide.
5




A COMPLETE RANGE OF HEAT
PUMPS FROM 5KW TO 400KW,
A BRAND THAT IS SYNONYMOUS
   WITH RELIABILITY & QUALITY,
WITH ALL THE ADVANTAGES THAT ONLY
A LEADING MANUFACTURING CAN OFFER.




With more than 40 years of experience in air conditioning, DeLonghi-Climaveneta is truly a
leading organisation in the expanding domestic, commercial and industrial heat pump market.


1ST IN EUROPE & 5TH IN THE WORLD
The mission and values that have guided us for 40 years have enabled us to become the number one manufacturer in Europe and the
fifth in the world within the temperature control sector.


+ 90,000m² of productive area
+ 5 specialist focused manufacturing plants, 4 located in Italy
  and 1 located in Shanghai China
+ Complete range of products from 1kW to 2400kW
+ Optimised heat pumps from 5kW to 400kW (modular)
+ First heat pump manufactured in 1979
+ Now 12 ranges of air source and ground source/geothermal
+ Residential and commercial equipment




                                                            Commercial Heat Pumps                        Residential Heat Pumps
6




    ICS HEAT PUMP
    TECHNOLOGY
    ICS Heat Pump Technology provides a complete service offering design/specification support,
    supply/commissioning services and after sales support for air source heat pumps, ground source heat
    pumps and geothermal heat pumps within both the commercial and residential sectors.

    ICS has been providing temperature control systems and heat transfer equipment for an extensive range
    of applications and users since 1988. Twenty years of experience has resulted in an extremely well
    established business operating throughout the UK, Germany and Ireland employing over 200 people with
    a combined group turnover of circa £30m.



    PROVEN TECHNOLOGY                                                                  A COMPANY YOU CAN TRUST
                                                                                       • An ICS group company
    Massive reductions in carbon emissions can be achieved by using heat pumps
                                                                                       • Established over 20 years
    and significant cost savings are possible by increasing the efficiency of a
    property when a heat pump system is installed.                                     • £30m turnover throughout UK and Europe
                                                                                       • Over 200 specialised and highly skilled
    Ground source or geothermal heat pumps along with air source heat pumps              employees
    take low grade energy from the earth or atmosphere and convert it into high
                                                                                       • Excellent reputation in climate control
    grade heat energy to be used within the property
                                                                                         services
    Whether a new build project or a retrofit application, the range of heat pumps     • Provides a complete service
    provided by Climaveneta and DeLonghi Professional is able to provide a practical   • Implements a “best advice” policy to all
    and cost effective solution to heating and sanitary hot water requirements from      customers
    5kW to 1200kW.
7




     APPROVED PARTNER PROGRAMME


   SUPPORT
  ICS Heat Pump Technology & DeLonghi-Climaveneta
  provides a specialist support service to their
                                                                                                                         HEAT PUMP
  customer base, which is designed to assist the heat
  pump specifier or installer in maximising the fast
  developing opportunity within the renewable                                                                                APPROVED PARTNER PROGRAMME

  heating sector.

  We understand that providing high quality equipment is only half of the package which is why the ICS Approved
  Partner Programme (APP) has been developed over the past two and a half years in order to provide the specifier
  or installer with the complete heat pump support service to accompany the 12 ranges of residential and commercial
  heat pumps provided by DeLonghi-Climaveneta.

  The ICS APP is split into 4 main elements each of which provides the specifier or installer with a range of specialist
  areas to support their business.



       apptraining
       apptraining                       £££
                                               appmarketing
                                               appmarketing                             apptechnical
                                                                                        apptechnical                              appinfocentre
                                                                                                                                  appinfocentre
• LOGIC ACCREDITED APP               •   PARTNER BRANDED WEBSITE APP            •   TECHNICAL SUPPORT DESK APP           •    CPD APP
• PRODUCT DAY APP                    •   SALES/PRODUCT SUPPORT LITERATURE APP   •   FIELD BASED TECHNICAL SUPPORT APP    •    INDUSTRY NEWS APP
• IN COMPANY SALES & TECHNICAL APP   •   ICS-DELONGHI NATIONAL MARKETING APP    •   FACTORY SUPPORT APP                  •    MSC APP
• FIELD SUPPORT APP                  •   DIRECT MARKETING/EXHIBITION            •   INSTALLER/SPECIFIER INTERNET BASED   •    LEGISLATION APP
                                         SUPPORT APP                                PARTNER HUB APP




                                                                         Commercial Heat Pumps                                    Residential Heat Pumps
8




    CASE STUDIES
    RESIDENTIAL CASE STUDY NEW BUILD WITH SUBSTANTIAL REFURBISHMENT
    Property:         5 bedroom 400sq/m high specification low energy house
    Application:      New build with substantial refurbishment
    Locations:        North West Coast
    Accreditations:   MSC Accredited equipment used
    Installation:     ICS Heat Pump Technology Approved Partner
    Equipment:        1 x DeLonghi Professional i-NRG 16.3kW Inverter
                      Air Source Heat Pump
                      1 x 200L Buffer Tank
                      1 x 300L Optimised unvented cylinder
                      1 x 35L Inertia tank
                      5 x Climaveneta i-life fan coil terminals
                      4 x DeLonghi-Climaveneta system/room controllers




    RESIDENTIAL CASE STUDY BBC DIY SOS LOW COST HOUSING
    Property:         Affordable Housing
    Application:      Refurbishment & New Build
    Locations:        Wales
    Accreditations:   MSC Accredited equipment used
    Installation:     ICS Heat Pump Technology Approved Partner
    Equipment:        1 x De-Longhi Climaveneta BRAN H 0011 Air
                      Source Heat Pump
                      1 x Tank In Tank DHW Cylinder
                      1 x Installation Kit




    RESIDENTIAL CASE STUDY LARGE NEW BUILD
    Property:         5 Bedroom Country House
    Application:      New Build
    Locations:        Midlands
    Accreditations:   MSC Accredited equipment used
    Installation:     ICS Heat Pump Technology Approved Partner
    Equipment:        1 x De-Longhi Climaveneta Z1T17 Cube Ground
                      Source Heat Pump
                      800m PEX-A Pipework in Horizontal Straight
                      Formation
                      1 x 300L Twin Coil Heat Pump Cylinder
                      1 x 100L Buffer Tank
9




COMMERCIAL CASE STUDY NEW BUILD SCHOOL
Property:         School
Application:      New Build School 90kW
Location:         Rural Lancashire Town
Installer:        North West based - ICS Approved Partner
                  Installer
Equipment:        1 x BWR DHW 0101 1 x BWR MTD 0101,
                  2 x 400L Buffer Tank




COMMERCIAL CASE STUDY SUPERSTORE HEATING PROJECT
Property:         Superstore
Application:      Space heating - Mono-valent system 360kW
Locations:        Scotland
Accreditations:   MSC Accredited equipment used
Installation:     ICS Heat Pump Technology Approved Partner
Equipment:        ICS-Climaveneta 8 x MICS N 0182 Air Source
                  Heat Pumps & 2 x Buffer Tanks




COMMERCIAL CASE STUDY AMBULANCE STATION RETROFIT
Property:         NHS Ambulance Station
Application:      Retrofit ‘Off Gas’ Boiler Replacement 20kW
Locations:        South West England
Equipment:        1 x 20kW high temperature 65ºC
                  Climaveneta AW HT Air Source Heat Pump
Emitter:          Radiators




COMMERCIAL CASE STUDY SPACE HEATING & COOLING
Property:         Office & Warehousing
Application:      Refurbishment 120kW
Locations:        North West England
Accreditations:   MSC Accredited equipment used
Installation:     ICS Heat Pump Technology Approved Partner
Equipment:        2 x De-Longhi Climaveneta DHW Air Source
                  Heat Pumps
                  1 x De-Longhi Climaveneta MICS-N Air Source
                  Heat Pump
                  2 x ICS HTP Buffer Tanks
                  Various DeLonghi Climaveneta Fan Coils
                  Various DeLonghi Climaveneta Air Handling
                  Units




                                                            Commercial Heat Pumps   Residential Heat Pumps
10




     AIR SOURCE
     MEDIUM & HIGH
     TEMPERATURE HEAT PUMPS

     MEDIUM TEMPERATURE AIR SOURCE HEAT PUMPS
              Unit &        Hot        Heating     Simultaneous          Cooling      Simultaneous            Heat      Reduced     Lower    Modular
             Capacity      Water                     Heating/            (Optional)      Cooling,           Recovery     Carbon    Heating
                                                     Hot Water                         Hot Water/                      Emissions     Costs
                                                                                         Heating



            BRAN H
            6-14kW         HOT WATER     HEATING
             pg 12-13
            Residential




          AWR MTD XE
            6-25kW
             pg 14-15      HOT WATER     HEATING                           COOLING



           Residential &
            Commercial




           DHW Twin
            20-33kW        HOT WATER     HEATING   HEATING
                                                             HEATING +
                                                                           COOLING    COOLING
                                                                                                COOLING +
                                                             HOT WATER                          HOT WATER
             pg 16-17
            Commercial




            MICS N
           20-50kW
                                         HEATING                           COOLING                                                            MODULAR
             pg 18-19
            Commercial
11



Our air source heat pumps provide a very efficient means of utilising renewable energy
whilst being very straightforward in their installation.

The DeLonghi-Climaveneta range of air source heat pumps provides units with
capacities from 5kW to 200kW which are suitable for a wide range of applications.

Single phase 240v powered air source heat pump units are available up to a capacity
of 14kW and three phase 415v units complete the range for larger residential heat
pump and commercial applications.

Modular capability allows for the multiple connection of up to six units operating as
one single package, hence large capacity projects can be specified by utilising this                                 AIR SOURCE HEAT PUMPS
modular configuration approach. The single controller ensures that running hours are                                 Heat energy is collected from the external ambient air
equalised & maintained across the various heat pumps whilst also ensuring that the                                   using the heat pumps integral evaporator coil. This energy
                                                                                                                     is then transferred as high grade heat into the building.
system operates with maximum modular part load efficiency at all times.


HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION



     HIGH TEMPERATURE AIR SOURCE HEAT PUMPS
                       Unit &        Hot        Heating     Simultaneous          Cooling      Simultaneous               Heat         Reduced         Lower       Modular
                      Capacity      Water                     Heating/            (Optional)      Cooling,              Recovery        Carbon        Heating
                                                              Hot Water                         Hot Water/                            Emissions         Costs
                                                                                                  Heating



                       i-KI
                      9.5kW         HOT WATER     HEATING                                                                                                             MODULAR
                      pg 20-21
                     Residential




                     HT 65ºC
                    10-27kW
                      pg 22-23      HOT WATER     HEATING                                                                                                             MODULAR



                    Residential &
                     Commercial




                      i-NRG
                     16.3kW         HOT WATER     HEATING   HEATING
                                                                      HEATING +
                                                                                    COOLING    COOLING
                                                                                                         COOLING +
                                                                                                                                                                      MODULAR
                                                                      HOT WATER                          HOT WATER
                      pg 24-25
                     Residential




                   PRANA HT
                    40-100kW
                                    HOT WATER     HEATING                           COOLING                                                                           MODULAR
                      pg 26-27
                     Commercial




                                                                              Commercial Heat Pumps                                          Residential Heat Pumps
12
                                                                                                                                                                     Bran H

                                                                                                            Unit Description                                                              HEATING     HOT WATER




                                                                                                            The DeLonghi Prana Bran H range of air source heat pumps provide a high
                                                                                                            level of performance along with a high level of specification but in a very
                                                                                                            cost effective package.


                                                                                                            • The nominal refrigeration COP* (efficiency) of these units is high
                                                                                                              averaging over 4.0 but importantly the performance of these units
                                                                                                              when operating in lower ambient temperatures is also at a high
                                                                                                              level. Designed to operate in ambient temperatures as low as -15ºC
                                                                                                              the Bran H range is more than capable of operating in UK & Irish
                                                                                                              winter temperatures.


                                                                                                            • These units incorporate a built in heating system circulation pump,
                                                                                                              control for hot water production including Y Plan valve (optional, not
                                                                                                              supplied as standard) operation along with full weather compensation
                                                                                                              and controls which give a very short defrost cycle in lower ambient
                                                                                                              temperatures.

                                                                                                            • The Bran H range will operate with a standard 2 channel time clock or
                                                                                                              programmable room stat, please contact technical support for
                                                                                                              clarification or specification details.

                                                                                                            • The Bran H range will function with any heat pump optimised DHW
                                                                                                              cylinder allowing flexibility in terms of stored water volume to match
                                                                                                              the demands of each particular project.
     Unit Summary
                                                                                                            • This advanced control means that these units are able to operate with
     BRAN H UNITS: AW                                                                                         very low system volumes, a minimum open circuit volume of 3.5 litres
     CAPACITY: 6kW-14kW                                                                                       per nominal kW of heat pump capacity is required which can reduce
                                                                                                              installation costs considerably. A buffer tank is recommended to
     POWER SUPPLY: Single Phase models                                                                        achieve maximum operational efficiency in order to provide thermal
                                                                                                              mass and efficient defrost capability.
     A cost effective high specification air source solution providing
     heating and hot water up to 55ºC output temperature (50ºC at                                           • These DeLonghi-Climaveneta units are high specification heat pumps
     -3ºC ambient)                                                                                            which are built to exacting standards with regard to efficiency and
                                                                                                              functionality. All the units are European manufactured and benefit from
     HIGH EFFICIENCY & PERFORMANCE: COP 4.01 (401% efficient)                                                 the DeLonghi-Climaveneta approach to product development and
                                                                                                              quality management providing the complete package that would be
     *Average coefficient of performance (COP) for the Bran H range based on an ambient
     temperature of 7ºC and 35ºC flow temperature
                                                                                                              expected from a premier manufacturer.

     COP 3.6 (360% efficient @ 2ºC ambient & 35ºC flow temp)
     NOTE. Actual system efficiency (COP) and annual performance will depend on the
     distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed
     in order to provide efficient operational performance.                                                            AXIAL




     FEATURES & OPERATIONAL BENEFITS:                                                                       *(COP is shown without circulation pump input power. Please note that unlike most other heat
     • MSC accredited heat pumps, certificate HP0005                                                        pumps these units incorporate built in circulation pumps, therefore by not including the circulation
                                                                                                            pump input power we are able to provide a direct performance comparison with other units).
     • Cost effective
     • High efficiency
     • Full DHW and heating control
     • Built in circulation pump                                                                             • Microgeneration scheme accreditation allows
     • High COP                                                                                                access to grant funding and also guarantees
                                                                                                               performance and manufacturing quality.
     • Full floating control for high efficiency & minimum defrost
                                                                                                                                                                                  Certificate Number MSC HP0005
       time to -15°C ambients                                                                                                                                                                Heat Pumps
13

                                                                  Bran H Air Source Medium Temperature Heat Pumps


Main Components

• Condensate drain pan kit.                                                                                                               • The electronic controller menu allows management of:
• Condensing coil protection grills                                                                                                         - circulation pump on the system side
                                                                                                                                            - domestic hot water production via control of the external three-way
• Housing and base are made from hot-galvanized epoxy powder coated
                                                                                                                                              valve (not supplied)
  sheet metal
                                                                                                                                            - 24 hour timer operation for a cylinder heater
• High efficiency and low pressure drop stainless steel (AISI 316) water                                                                    - control of the incorporated supplementary heating element
  exchangers, with anti-freeze heating element and differential pressure                                                                    - outdoor temperature sensor for modulating set point weather
  switch                                                                                                                                      compensation
• Hermetic scroll type compressors, equipped with the crankcase heater                                                                    • Soft start for 230V/1/50Hz units (45 amps & 25 amps for the 0011
  and thermal protection                                                                                                                    model)
• Condensers finned tubes with copper and aluminium fins high exchange                                                                    • Phase sequence control relay
  surface (100% fully quality tested); sub cooling circuit to prevent freezing
                                                                                                                                          • The water circuit comes complete with:
  at the base.
                                                                                                                                            - variable flow circulation pump for all models
• Axial electric fans, external rotor, electric motor with a 6-pole fitted with                                                             - differential pressure switch on plant side
  thermal protection, housed in an aerodynamic profile with safety grill                                                                    - expansion vessel (Heat Pump circuit only)
• Low external air temperature device:                                                                                                      - safety valve
  - fan speed regulation with pressure switch which maximises                                                                               - manual filling assembly- pressure gauge- manual air vent valve
  efficiency at part load                                                                                                                 NB: Optional equipment includes a range of tanks & cylinders plus
• Electrical modulating frost protection heating within the base which                                                                    standard installation packs, see current price list or contact ICS HPT or your
  minimizes the risk of condensate freezing during periods of low ambient                                                                 distributor for details.
  temperature

Bran H                                                                                                                                        0011M                                      0025M                       0041M
Heating capacity                                                                                                  (1)    kW                   6.5                                        8.7                         13.8
Effective input power according to EN 14511                                                                       (1)    kW                   1.82                                       2.31                        3.68
Heating capacity                                                                                                  (2)    kW                   6.5                                        8.7                         13.8
Power absorbed                                                                                                    (2)    kW                   1.65                                       2.15                        3.40
COP*                                                                                                              (2)                         3.94                                       4.05                        4.06
Rated water flow                                                                                                  (1)    m3/h                 1.12                                       1.50                        2.37
Residual head                                                                                                     (1)    kPa                  41                                         48                          89
Fans                                                                                                                     n0                   1                                          1                           2
Air flow                                                                                                                 m3/s                 0.9                                        1                           1.9
Type of compressor                                                                                                                                                                       Scroll
No. of compressors                                                                                                       n0                   1                                          1                           1
No. of circuits                                                                                                          n0                   1                                          1                           1
Refrigerant R410A                                                                                                        kg                   1.75                                       3                           3
Oil Mobil EAL ARTIC 22cc                                                                                                 kg                   1.1                                        1.24                        1.95
Pump type                                                                                                                                                                                circulator
No. of pumps                                                                                                          n0                      1                                          1                           1
Functioning weight                                                                                                    kg                      95                                         115                         140
Hydraulic connections                                                                                                 inches                  3/4                                        3/4                         1 1/4
Sound pressure level according to EN ISO 3744                                                                         dB(A)                   72                                         73                          73
Sound pressure                                                                                                    (3) db(A)                   58                                         59                          59
Electric power supply                                                                                                 V/ph/Hz                                                            230-510


Common Data                                                                                                                                   0011                                       0025                        0041
Circulation pump                                                                                                                                                                         Included
DHW control                                                                                                                                                                              Included
Height/Length/Width                                                                                                      mm                   640/900/370                                940/900/370                 1240/900/370
Weight                                                                                                                   kg                   105                                        130                         160

                                                                                                                                                                                                                               L


Note:
1. Heat pump mode: external air temperature 7°C DB/6°C WB, water in flow at 30°C and outlet at 35°C                                                                                                                                     H
2. The total input is given by the compressor input and fans power input
3. Free field sound pressure on a reflecting surface (directivity fact. Q=2), at a distance of 1 meters                                                                                                H
   from the external surface of the unit. Average value calculated from the sound power


                                                                                                                                                                                                                                        W
                                                                                                                                                                                                           L           W




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
details at point of quotation and/or order.                                                                                                                                                                    Residential Heat Pumps
14
                                                                                                                                    AWR MTD XE

                                                                                                            Unit Description                                                HEATING       COOLING     HOT WATER




                                                                                                            The DeLonghi Prana AWR MTD XE range of air source heat pumps provide
                                                                                                            an extremely high level of performance and a high level of specification.
                                                                                                            The nominal refrigeration COP* (efficiency) of these units is very high
                                                                                                            averaging over 4.17 and importantly the performance of these units
                                                                                                            when operating in lower ambient temperatures is also at a very high
                                                                                                            level. Designed to operate in ambient temperatures as low as -15ºC the
                                                                                                            AWR MTD XE range is more than capable of operating with high efficiency
                                                                                                            in UK & Irish winter temperatures.

                                                                                                            • These units incorporate a built in heating system circulation pump,
                                                                                                              control for hot water production including Y Plan valve (optional, not
                                                                                                              supplied as standard) operation along with full weather compensation
                                                                                                              and sophisticated controls which give a very short defrost cycle in lower
                                                                                                              ambient temperatures.

                                                                                                            • The AWR MTD range will operate with a standard 2 channel time clock
                                                                                                              or programmable room stat, please contact technical support for
                                                                                                              clarification or specification details.

                                                                                                            • A modulating source fan controls efficiency and maximises the
                                                                                                              performance on part loads by drawing the correct amount of air
                                                                                                              through the unit to match the load requirement of the property at any
                                                                                                              time, so reduces running costs and also allows the units to function
                                                                                                              with any Heat Pump optimised thermal store or cylinder.

     Unit Summary                                                                                           • This advanced control means that these units are able to operate with
                                                                                                              very low system volumes, a minimum open circuit volume of 3.5 litres
     MTD UNITS: AWR MTD XE                                                                                    per nominal kW of Heat Pump capacity is required which can reduce
     CAPACITY: 6kW-25kW                                                                                       installation costs considerably. A buffer tank is recommended to
                                                                                                              achieve maximum operational efficiency in order to provide thermal
     POWER SUPPLY: Single Phase & Three Phase models                                                          mass and efficient defrost capability.
     These units can provide heating or cooling and hot water up to
     55ºC, the efficient unit design incorporating supplementary                                            • In addition to these features these units also have a built in
     heating enables the AWR MTD XE to operate efficiently in low                                             supplementary heater which provides additional capacity in ambient
     ambient conditions to -15ºC.                                                                             temperatures below -5ºC.

     HIGH EFFICIENCY & PERFORMANCE: COP 4.17 (417% efficient)                                               • These units also provide reversible operation, this means they can
     *Average coefficient of performance (COP) for the AWR MTD XE range based on an                           provide cooling whilst being able to prioritise hot water production,
     ambient temperature of 7ºC and 35ºC flow temperature.                                                    this means that when connected via a fan coil distribution system these
     NOTE. Actual system efficiency (COP) and annual performance will depend on the
                                                                                                              AWR MTD units can provide a complete residential or light commercial
     distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed     climate control option.
     in order to provide efficient operational performance.

                                                                                                            • These DeLonghi-Climaveneta units are high specification heat pumps
     FEATURES & OPERATIONAL BENEFITS:                                                                         which are built to exacting standards with regard to efficiency and
     • MSC accredited heat pumps (AWR MTD XE accreditation pending)                                           functionality. All the units are European manufactured and benefit from
                                                                                                              the DeLonghi-Climaveneta approach to product development and
     • Full DHW and heating control
                                                                                                              quality management providing the complete package that would be
     • Reversible operation can provide cooling for A/C applications                                          expected from a premier manufacturer.
     • Built in circulation pump
     • 55ºC output temperature (50ºC at -5ºC ambient)
     • High efficiency modulating source fan(s) and circulation pump                                                   AXIAL




     • Minimum defrost time operating to -15ºC ambients
     • Supplementary Electric Heating Included for -5ºC ambient                                             *(COP is shown without circulation pump input power. Please note that unlike most other heat
       operation                                                                                            pumps these units incorporate built in circulation pumps, therefore by not including the circulation
                                                                                                            pump input power we are able to provide a direct performance comparison with other units).
15

                                                               MTD XE Air Source Medium Temperature Heat Pumps


Main Components

• Condensate drain pan kit.                                                                                                    • Soft start for 230V/1/50Hz units (45 amps)
• Condensing coil protection grills                                                                                            • Reversible operation allows the production of chilled water for an
• Housing and base are made from hot-galvanized epoxy powder coated sheet                                                        air-conditioning circuit
  metal                                                                                                                        • The electronic controller menu allows management of:
• High efficiency and low pressure drop stainless steel (AISI 316) water                                                         - circulation pump on the system side
  exchangers, with anti-freeze heating element and differential pressure switch                                                  - domestic hot water production via control of the external three-way valve
• Hermetic scroll type compressors, equipped with the crankcase heater and                                                       (not supplied)
  thermal protection                                                                                                             - 24 hour timer operation for a cylinder heater
• Condensers finned tubes with copper and aluminium fins high exchange                                                           - control of the incorporated supplementary heating element
  surface (100% fully quality tested); sub cooling circuit to prevent freezing at                                                - outdoor temperature sensor for modulating set point weather
  the base.                                                                                                                        compensation
• Axial electric fans, external rotor, electric motor with a 6-pole fitted with                                                • Phase sequence control relay
  thermal protection, housed in an aerodynamic profile with safety grill                                                       • The water circuit comes complete with:
• Low external air temperature device:                                                                                           - variable flow circulation pump for all models
  - fan speed regulation with pressure switch which maximises efficiency at                                                      - differential pressure switch on plant side
  part load                                                                                                                      - expansion vessel (Heat Pump circuit only)
• Electrical modulating frost protection heating within the base which minimises                                                 - safety valve
  the risk of condensate freezing during periods of low ambient temperature                                                      - manual filling assembly- pressure gauge- manual air vent valve

NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.


AWR-MTD XE                                                                   0011MS               0025MS            0031MS       0041MS       0031T       0041T        0051T        0061T       0091T
Nominal heating power                                   (1) kW               6.30                 7.40              11.2         14          10.9         14           15.9         17.9        25.10
Total absorbed power                                    (2) kW               1.50                 1.80              2.60         3.30        2.60         3.30         3.80         4.20        6
COP                                                                          4.13                 4.15              4.22         4.16        4.15         4.15         4.11         4.25        4.19
Cooling capacity                                        (3) kW               7.20                 8.30              12.3         15.7        11.7         15.8         17.7         20.2        29.2
Total absorbed power                                    (2) kW               1.90                 2.20              3.30         4.10        3.10         4.20         4.70         5.30        7.80
EER Eurovent *                                                               3.79                 3.77              3.73         3.83        3.77         3.76         3.77         3.81        3.74
EER                                                                          3.82                 3.82              3.81         3.84        3.84         3.81         3.81         3.81        3.85
Heating capacity                                        (4) kW               6.10                 7.30              10.8         13.6        10.6         13.8         15.4         17.5        24.60
Total absorbed power                                    (2) kW               1.90                 2.30              3.30         4.10        3.20         4.30         4.60         5.20        7.40
Cooling capacity                                        (5) kW               5.20                 6.30              9.20         11.7        8.60         11.9         13.2         15.2        22.10
Total absorbed power                                    (2) kW               1.70                 2.20              3.10         4.00        3.00         4.00         4.60         5.00        7.20
EER Eurovent *                                                               3.06                 2.86              2.97         2.93        2.87         2.98         2.87         3.04        3.07
ESEER                                                                        3.62                 3.63              3.52         3.46        3.42         3.65         3.24         3.55        3.57
Compressor type                                                                                                                              SCROLL
N. Compressors                                                 N.                                                                            1
Refrigerant                                                                                                                                  R410A
N. fans                                                        N.   1                             1                 2            2           2            2            2            2           3
Plant side pump type                                    (6)         Ci                            Ci                Ci           Ci          Ci           Ci           Ci           Ci          Ci
Electrical power supply                                     V-Ph~Hz 230-1~50                      230-1~50          230-1~50     230-1~50    400-3N~50    400-3N~50    400-3N~50    400-3N~50   400-3N~50
Start-up current                                            A       27                            30                45           45          48           64           64           75          111
Sound power                                             (7) dB(A) 69                              69                71           71          71           71           71           72          74
Sound pressure                                          (8) dB(A) 54                              54                56           56          56           56           56           57          58
L                                                           mm      900                           900               900          900         900          900          900          1550        1550
H                                                           mm      1240                          1240              1240         1390        1240         1390         1390         1200        1700
W                                                           mm      420                           420               420          420         420          420          420          450         450
Operational weight                                          kg      145                           150               155          170         155          170          180          250         335

                                                                                                                                                                                                L
Note:
1.   Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.
2.   Total input is obtained from compressor input and fan input
3.   Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s.
4.   Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.                                                                                                                          H
5.   Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s.
6.   Ci=Circulator; Ce=Centrifugal                                                                                                                                H
7.   Sound power level according to ISO 9614 and Eurovent 8/1
8.   Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.
*    According to the Eurovent standard without circulation pump input power.                                                                                                                               W
                                                                                                                                                                          L           W




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right
to change update or alter the specification & details of any item shown with or without prior notice for whatever
reason. The information provided within the product guide and/or data sheets is intended for guidance purposes
only, please confirm actual current specification and equipment details at point of quotation and/or order.
                                                                                                                           Commercial Heat Pumps                              Residential Heat Pumps
16
                                                                                                                                             DHW Twin
                                                                                                        Unit Description
                                                     HEATING +      COOLING +
            HEATING
        HEATING           COOLING
                        COOLING        HOT WATER     HOT WATER      HOT WATER

                                                                                                        The DeLonghi Prana AWR DHW are a unique range of commercial air
                                                                                                        source heat pumps which are capable of providing a high efficiency
                                                                                                        combination of output conditions:
                                                                                                        •      Heating only
                                                                                                        •      Simultaneous heating and hot water to 55ºC**
                                                                                                        •      Hot water only
                                                                                                        •      Cooling only
                                                                                                        •      Simultaneous cooling and hot water with up to 100% heat recovery***
                                                                                                        •      Simultaneous cooling and heating with up to 100% heat recovery***
                                                                                                        These units can be specified to suit a particular application and due to
                                                                                                        their ability in being able to provide two simultaneous outputs they are
                                                                                                        able to provide real benefits on both large residential and commercial
                                                                                                        applications.
                                                                                                        Within the commercial sector the AWR DHW range provides flexibility and
                                                                                                        real environmental benefits. These Heat Pumps will provide up to 100%
                                                                                                        heat recovery which then benefits the user with free heating or hot water.
                                                                                                        A growing demand for energy and heat recovery has created a highly
                                                                                                        efficient requirement to use these units to recover waste energy from
                                                                                                        waste water or fluid flows, recovering energy from cooling towers or
                                                                                                        waste water flows is easily achievable when utilising these units in heat
                                                                                                        recovery specification.
                                                                                                        Also these heat pump units will provide up to 100% duty on either
                                                                                                        primary or secondary heat exchangers along with the ability to provide
                                                                                                        a combination of heating and hot water simultaneously or heating and
                                                                                                        cooling simultaneously with up to 100% heat recovery. This allows these
                                                                                                        heat pump units to provide this simultaneous output feature to manage
                                                                                                        seasonal heating and cooling loads from the same heat pump unit***.
 Unit Summary                                                                                           These DeLonghi-Climaveneta units are high specification heat pumps
                                                                                                        which are built to exacting standards with regard to efficiency and
 DHW TWIN UNITS: AWR                                                                                    functionality. All the units are European manufactured and benefit from
                                                                                                        the DeLonghi-Climaveneta approach to product development and quality
 CAPACITY: 20kW-33kW                                                                                    management providing the complete package that would be expected
 POWER SUPPLY: Single Phase & Three Phase models                                                        from a premier manufacturer.

 These units provide simultaneous supplies of domestic hot                                                          r HFC     r HFC
 water and heating/air conditioning.                                                                        AXIAL
                                                                                                                     R-410A
                                                                                                                      AXIAL
                                                                                                                               R-410A



 HIGH EFFICIENCY & PERFORMANCE: COP 3.87 (387% efficient)                                               *(COP is shown without circulation pump input power. Please note that unlike most other heat
                                                                                                        pumps these units incorporate built in circulation pumps, therefore by not including the circulation
 *Average coefficient of performance (COP) for the AWR DHW range based on an                            pump input power we are able to provide a direct performance comparison with other units).
 ambient temperature of 7ºC and 35ºC flow temperature
                                                                                                        **A higher temperature DHW output is available when the unit is operating in heating mode.
 NOTE. Actual system efficiency (COP) and annual performance will depend on the                         The actual available capacity of DHW is dependent on the heating output being provided at any
 distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed   time. The available part load DHW capacity will vary dependant on the part load capacity
 in order to provide efficient operational performance.                                                 available in-line with the above.

 FEATURES & OPERATIONAL BENEFITS:                                                                       ***The AWR DHW range of units are designed to provide simultaneous heating/DHW and cooling
                                                                                                        when operating in ambient temperatures above 10ºC unless a year round cooling load is
 • MSC accredited heat pumps, certificate HP0005                                                        available. Please contact ICS Heat Pump Technology Technical Support to confirm the suitability
                                                                                                        of this range of equipment for each application.
 • Fully self-contained unit – no external refrigerant pipes
 • Standard pipe work installation to suit a plumber or heating
   engineer
 • Highly efficient and flexible design with easy to use controls
                                                                                                         • Microgeneration scheme accreditation allows
 • Heating, cooling and domestic hot water provided                                                        access to grant funding and also guarantees
 • Suitable for large capacity hot water users and simultaneous                                            performance and manufacturing quality.
   heating & air conditioning applications                                                                                                                                    Certificate Number MSC HP0005
                                                                                                                                                                                         Heat Pumps




                                                                                                                                                                 Commercial Heat Pumps
17

                                                    DHW Twin Air Source Medium Temperature Heat Pumps


Main Components

• Housing and base are made from hot-galvanized epoxy powder coated sheet metal                                                           • Secondary stainless steel plate heat exchanger providing an output kW capacity
• Hermetic scroll type compressors, equipped with the crankcase heater and                                                                  up to 100% of the heat pump duty with high efficiency and low pressure drop
  thermal protection                                                                                                                        provides the supply of both hot or cold water for the application with or without
                                                                                                                                            any hot water or heating production on the primary heat exchanger.
• Condensers finned tubes with copper and aluminium fins high exchange surface
  (100% fully quality tested); sub cooling circuit to prevent the icing at the base     • The water circuit comes complete with:
                                                                                          - primary circuit water pump for domestic hot water or heating circuit
• Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal
  protection, housed in aerodynamic profile with safety grill.                            - secondary circuit plant side water pump for heating or cooling circuit
                                                                                          - differential pressure switch on plant side
  - continuous fan speed regulation with pressure switch for modulating load
  management                                                                              - expansion vessel Heat Pump circuit only
                                                                                          - safety valve (6 bar)
• Primary stainless steel (AISI 316) plate heat exchanger with high efficiency and
                                                                                          - manual filling assembly
  low pressure drop (providing domestic hot water or heating) positioned directly
                                                                                          - Pressure gauge
  after the compressor which gives an efficient high temperature output providing
  an output kW capacity up to 100% of the Heat Pump duty.                                 - venting and draining valve

• When combined with the secondary heat exchanger (cooling duty) these units                                                              • Soft start for 230V/1/50Hz units AWR DHW/S
  will provide either full or partial heat recovery which is constantly optimised                                                         NB: Optional equipment includes a range of tanks & cylinders plus standard
  via the advanced logic adjusting controller.                                                                                            installation packs, see current price list or contact ICS HPT or your distributor for details.




               Prioritised hot water production in simultaneous DHW & heating mode                                                             Partial or 100% heat recovery available in simultaneous cooling & heating mode

                  HEATING + DOMESTIC HOT WATER**                                                                                                            HEATING + AIR CONDITIONING***

AWR DHW                                                                                                                                       0065SL                                                       0101SL
Heating capacity (A7/W35)                                                                           (1) kW                                    21.3                                                         33.5
Total power input (compressors & fans)                                                                  kW                                    5.6                                                          8.5
COP*                                                                                                                                          3.80                                                         3.94
Recovery heating capacity (A7/W50)                                                                  (2) kW                                    18.1                                                         31.9
Power input                                                                                             kW                                    7.7                                                          12.3
COP*                                                                                                                                          2.35                                                         2.59
Cooling Capacity (A35/W18)                                                                          (3) kW                                    21.1                                                         33.0
Total power input (compressors & fans)                                                                  kW                                    5.8                                                          9.4
EER*                                                                                                                                          3.64                                                         3.51
Cooling Capacity (A35/W7)                                                                           (4) kW                                    17.0                                                         27.7
Total power input (compressors & fans)                                                                  kW                                    5.9                                                          9.5
EER*                                                                                                                                          2.88                                                         2.92
Type of compressor                                                                                                                                                        scroll
N.° of compressors                                                                                         n°                                                               1
Refrigerant                                                                                                                                                              R407C
Plant side pump type                                                                                                                                                  centrifugal
DHW side pump type                                                                                                                                                     circulator
Power supply                                                                                        V/Ph/Hz                                                         400V-3N~ 50Hz
Starting current                                                                                        A                                     127                                                          101
Sound pressure                                                                                      (5) dB(A)                                 66                                                           62
Height/Length/Width                                                                                     mm                                    1200/1700/650                                                1700/1700/650
Net weight                                                                                              kg                                    295                                                          378

                                                                                                                                                                                                                           L
Note:
1.   Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 30°C and outlet at 35°C
2.   Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 45°C and outlet at 50°C
3.   Cooling mode: external air temperature 35°C b.s., inlet water at 23°C and outlet at 18°C
4.   Cooling mode: external air temperature 35°C b.s., inlet water at 12°C and outlet at 7°C                                                                                                                                          H
5.   Sound pressure at 1 meter distance from the external surface of the unit, free field.
*    According to the Eurovent standard without circulation pump input power.

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment                              W
details at point of quotation and/or order.
18
                                                                                                                                                                       MICS-N

                                                                                                                 Unit Description                                    HEATING       COOLING     MODULAR
                                                                                                                                                                                                            SUITABLE FOR
                                                                                                                                                                                                           SWIMMING POOLS




                                                                                                                 The Climaveneta MICS-N commercial heat pump range provides a fully
                                                                                                                 optimised Air Source Heat Pump installation with the capability to provide
                                                                                                                 a modular package in excess of 200kW in capacity which operates as a
                                                                                                                 single unit. This provides a very high specification air source installation
                                                                                                                 for both large residential and commercial applications.

                                                                                                                 • A high COP is achieved at nominal conditions with a high performance
                                                                                                                   and specification designed for medium temperature heating only.

                                                                                                                 • These units have twin compressors for maximum efficiency when
                                                                                                                   operating on partial load duty. They also have the ability to operate
                                                                                                                   with four heat pumps acting as a single unit i.e. three slaves and one
                                                                                                                   master where the lead unit will interface with a BMS system or
                                                                                                                   equivalent.

                                                                                                                 • These units are reversible and provide heating or cooling to match the
                                                                                                                   demands of the project.

                                                                                                                 • Each MICS-N single unit incorporates a twin compressor design which
                                                                                                                   provides a highly efficient output when operating under part load
                                                                                                                   conditions i.e. in modular multi unit/multi compressor configuration.
                                                            ***modular capability
                                                                                                                 • Circulation pumps are incorporated within the unit to give a complete
                                                                                                                   installed solution with a high specification and highly efficient system.
 Unit Summary                                                                                                      The full floating control and modulating performance of the system
                                                                                                                   provides a highly intelligent control function to give maximum
 MICS-N UNITS: AWR                                                                                                 performance and efficiency.
 CAPACITY: 20kW-50kW (modular parallel systems)
 POWER SUPPLY: Three Phase models                                                                                • The units also incorporate a vertical air discharge system which allows
                                                                                                                   for compact positioning of single or multiple units to fit into restricted
 These units provide medium to large capacity installations with a high                                            locations.
 efficiency modular system which can provide heating and air
 conditioning from 20kW to 1000kW (modular).                                                                     • These DeLonghi-Climaveneta units are high specification heat pumps
                                                                                                                   which are built to exacting standards with regard to efficiency and
 HIGH EFFICIENCY & PERFORMANCE: COP 3.85 (385% efficient)                                                          functionality. All the units are European manufactured and benefit from
 *Average coefficient of performance (COP) for the MICS-N range based on an ambient                                the DeLonghi-Climaveneta approach to product development and
 temperature of 7ºC and 35ºC flow temperature.                                                                     quality management providing the complete package that would be
 COP 3.77 (377% efficient @ 2ºC ambient & 35ºC flow temp)                                                          expected from a premier manufacturer.
 NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter
 system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient   NB: Optional equipment includes a range of tanks & cylinders plus
 operational performance.                                                                                        standard installation packs, see current price list or contact ICS HPT or your
 FEATURES & OPERATIONAL BENEFITS:                                                                                distributor for details.

 • MSC accredited heat pumps, certificate HP0005
                                                                                                                          r HFC     r HFC
 • Provides heating & cooling with a number of control options                                                    AXIAL
                                                                                                                           R-410A
                                                                                                                            AXIAL
                                                                                                                                     R-410A

 • Full BMS compatability with single control function for multiple units
                                                                                                                 *(COP is shown without circulation pump input power. Please note that unlike most other heat
 • Modular system which provides flexibility and ease of installation                                            pumps these units incorporate built in circulation pumps, therefore by not including the circulation
 • Vertical discharge fan with compact footprint for ease of positioning                                         pump input power we are able to provide a direct performance comparison with other units).
 • Very efficient twin compressor design provides high part load
   efficiency when providing heating and cooling on an annual basis
 • Fully self-contained unit – no external refrigerant pipes
 • Water based system which allows the heating and A/C installation to                                            • Microgeneration scheme accreditation allows
   be carried out by a mechanical contractor                                                                        Access to grant funding and also guarantees
                                                                                                                    Performance and manufacturing quality.
 • Highly efficient and flexible design which can be specified as a
                                                                                                                                                                                       Certificate Number MSC HP0005
   package with fan coils/internal air handlers                                                                                                                                                   Heat Pumps
19

                                                                MICS-N Air Source Medium Temperature Heat Pumps


                                                                                                                                                                Main Components
                                                                                                                                                                • Modular designed to minimise required installation space
                                                                                                                                                                • A Keyboard Master Control (KMPH) is the central control for multiple
                                                                                                                                                                    Units connected together with a primary function of supervising
                                                                                                                                                                    The operation of all the modules in synergy together.
                                                                                                                                                                • Flex Energy technology for automatic air flow, water flow and
                                                                                                                                                                  water temperature control
                                                                                                                                                                • Electronic thermostatic valve
                                                                                                                                                                • 20-50kW single units
                                                                                                                                                                • 50kW-1000kW packaged systems
                                                                                                                                                                • Twin compressor system per unit, maximum part load efficiency
                                                                                                                                                                • Compact footprint
                                                                                                                                                                • Vertical discharge fans
                                                                                                                                                                • The hydraulic unit comes complete with:
                                                                                                                                                                  - variable delivery pump
                                                                                                                                                                  - expansion tank
                                                                                                                                                                  - filling unit
                                              ***modular capability                                                                                               - discharge valve
                                                                                                                                                                  - air valve

MICS-N                                                                                                                   0072                         0092                        0122                     0152           0182
Heating capacity at full load                                                               (1) kW                       20.7                         26.2
                                                                                                                                                   34.5                                                    43.6           48.9
Absorbed power at full load                                                                 (1) kW                       5.3                       9.26.8                                                  11.3           12.5
COP at full load                                                                            (1)                          3.9                          3.85
                                                                                                                                                   3.75                                                    3.86           3.91
Nominal Cooling capacity                                                                    (1) kW                       17.3                         21.8
                                                                                                                                                   30.3                                                    37.4           42.5
Total absorbed power                                                                        (1) kW                       6.50                         9.30
                                                                                                                                                   10.7                                                    13.4           15.5
EER                                                                                         (1)                          2.66                         2.34
                                                                                                                                                   2.83                                                    2.79           2.74
ESEER                                                                                       (1)                          3.86                         3.75
                                                                                                                                                   3.78                                                    3.92           3.96
Nominal water flow                                                                          (1) m3/h                     3                            3.80
                                                                                                                                                   5.20                                                    6.40           7.30
Nominal Heating power                                                                       (2) kW                       20.2                         26.1
                                                                                                                                                   33.9                                                    42.6           47.9
Total absorbed power                                                                        (2) kW                       6.50                         8.60
                                                                                                                                                   11.2                                                    14             15.4
COP                                                                                         (2)                          3.11                         3.02
                                                                                                                                                   3.03                                                    3.04           3.11
Absorbed current                                                                            (3) A                        14                           17.7
                                                                                                                                                   23.9                                                     29.3          31.3
Nominal water flow                                                                          (3) m3/h                     3.50                         4.50
                                                                                                                                                   5.90                                                    7.40           8.30
Hydraulic connections                                                                       (3) inches                   1”1/4                        1”1/4
                                                                                                                                                   1”1/4                                                   1”1/4          1”1/4
Operational weight                                                                          (3) kg                       310                       410330                                                  450            480
No. fans                                                                                    (3) N.                       1                         2  1                                                    2              2
Airflow                                                                                     (3) m3/h                     9000                         9000
                                                                                                                                                   18000                                                   18000          18000
Compressor type                                                                                                                                    SCROLL
Refrigerant                                                                                                                                        R410A
Sound pressure level                                                                        (3) dB(A)                    68           68           71                                                      71             71
Sound power                                                                                     dB(A)                    80           80           83                                                      83             83
Electrical power supply                                                                         V-Ph~Hz                  400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz                                            400V-3N~50Hz   400V-3N~50Hz
Length                                                                                          mm                       1040         1040         1630                                                    1630           1630
Height                                                                                          mm                       1630         1630         1630                                                    1630           1630
Width                                                                                           mm                       790          790          790                                                     790            790


                    MODULAR CAPABILITY
   MODULAR
                    The MICS-N range is designed for modular application to accommodate multi unit larger capacity requirements***.



                                             INTERNAL VERSION
                                                                                                              Note:
                                                                                                              1. Evaporator water (in/out) 12/7°C, condenser air (in) 35°C,
                                             •    MICS-CN ducted unit                                            based on Eurovent standard
                                             •    20kW- 50kW capacity                                         2. Outdoor air temperature +7ºC CBS, 85% RH, water inlet                                      H
                                                                                                                 temperature +40ºC, outlet +45ºC. Compressors in operation: A+B
                                             •    Modular capability
                                                                                                              3. Noise level measured at 1 m in open field conditions
                                             •    Provides specification                                      4. Outdoor air temperature +35ºC, water inlet temperature +12ºC,
                                                  flexibility                                                    outlet +7ºC. Compressors in operation: A+B
                                                                                                                                                                                                                 W            L




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without           Commercial Heat Pumps
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
details at point of quotation and/or order.
20
                                                                                                                                                                                              i-KI

                                                                                                                 Unit Description                      HEATING     HOT WATER     MODULAR
                                                                                                                                                                                              SUITABLE FOR
                                                                                                                                                                                             SWIMMING POOLS   BI-VALENT



                                                                                                                 • The 60ºC DeLonghi Professional i-KI 9.5kW Inverter driven
                                                                                                                   air source heat pump is suitable for either new build or
                                                                                                                   retrofit applications with efficient performance and a low
                                                                                                                   noise level of 50dB(A) at 1m. A circulation pump is incorporated within
                                                                                                                   the unit for ease of installation and a remote weather sensor is provided
                                                                                                                   which will allow the unit to be positioned in any location whilst operating
                                                                                                                   with a high performance weather compensated heating output.

                                                                                                                 • The integrated controller accurately follows the actual load of the
                                                                                                                   building utilising a modulating DC inverter source fan and modulating
                                                                                                                   circulation pumps in order to maximise performance.

                                                                                                                 • The i-KI incorporates the new Climaveneta integrated heating zone + DHW
                                                                                                                   + solar controller as standard specification. This allows the specifier to
                                                                                                                   incorporate all the required elements of system control with complete
                                                                                                                   flexibility within the single i-KI heat pump controller.

                                                                                                                 • The 50dba low noise performance of this unit allows for flexibility in
                                                                                                                   positioning and location and the in-built modulating circulation pump
                                                                                                                   provides the installer with a unit which is very straightforward to install and
                                                                                                                   commission. The NADI integrated controller also provides full domestic hot
                                                                                                                   water prioritisation controlling the system three port valve (optional, not
                                                                                                                   supplied as standard), in addition the i-KI is fully weather compensated
                                                                                                                   for efficient operation and performance via the remote wired weather sensor.

 Unit Summary                                                                                                    • The modulating circulation pump ensures that energy usage and output
                                                                                                                   are matched to meet demand ensuring that maximum performance and
 i-KI UNITS: Inverter Air Source                                                                                   control is maintained at all times.
 CAPACITY: 9.5kW
                                                                                                                 • The new Climaveneta NADI integrated electronic controller provides a high
 POWER SUPPLY: Single Phase models                                                                                 level of application flexibility and functionality. The remote keyboard kit
 This compact and high performing air source heat pump provides a                                                  with wired indoor and outdoor weather sensors allows dynamic control of
 high temperature 60ºC output temperature in ambients as low as                                                    delivered water temperature. The controller ensures full optimisation of
                                                                                                                   comfort within the property and increases overall energy efficiency,
 -5ºC and a 55ºC output temperature when operating in a -20ºC
                                                                                                                   providing the following functions:
 ambient condition. The unit provides a low noise level of 50dB(A) at
 1 meter and is complete with circulation pump, remote weather                                                   +   Single heating zone control for radiator, underfloor or fan coil
 sensor plus integrated heating zone control and solar thermal control*.                                         +   Multiple heating zone control available via optional expansion module
 High performance, high specification and high value.                                                            +   Solar thermal control via optional extension module
                                                                                                                 +   Remote weather sensor for accurate weather compensated performance
 HIGH EFFICIENCY & PERFORMANCE: COP 4.02 (402% efficient)**                                                      +   Anti-legionella cycle control for DHW cylinder
 Coefficient of performance (COP) for the 9kW i-KI based on an ambient temperature of                            +   Bi-valent control for additional heat source
 7ºC and 35ºC flow temperature
                                                                                                                 +   Modulating circulation pump and source fan provide maximum efficiency
 NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter
 system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient
 operational performance.
                                                                                                                                                   r HFC
 FEATURES & OPERATIONAL BENEFITS:                                                                                                          AXIAL
                                                                                                                                                    R-410A

 •   60ºC output temperature at -5ºC ambient                                                                     **(COP is shown without circulation pump input power. Please note that unlike most other heat
 •   Low noise level of 50dB(A) at 1m                                                                            pumps these units incorporate built in circulation pumps, therefore by not including the circulation
                                                                                                                 pump input power we are able to provide a direct performance comparison with other units).
 •   Freeze prevention drain pan heating included as standard
 •   High performance, delivers 55ºC at -20ºC ambient temperature
 •   Integrated NADI control for heat pump, heating zones* and solar thermal*
 •   Inverter driven providing flexibility in application and performance                                         • Microgeneration scheme accreditation allows
 •   Remote weather sensor provides flexibility in positioning and location                                         access to grant funding and also guarantees
 •   Built in circulation pump allows for simple installation                                                       performance and manufacturing quality.
                                                                                                                                                                                       Certificate Number MSC HP0005
 * standard unit controller for single heating zone control, optional extension modules allow further
                                                                                                                                                                                                  Heat Pumps
 heating zone control and solar thermal control
21

                                                                                            i-KI Air Source High Temperature Heat Pumps
 HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION



Main Components

•    Condensate drain pan kit.                                                       • The NADI electronic controller menu allows management of:
•    Condensing coil protection grills                                                 - circulation pump on the system side
•    Housing and base are made from hot-galvanized epoxy powder coated sheet metal     - domestic hot water production via control of the external three-way valve
                                                                                         (not supplied)
•    High efficiency and low pressure drop stainless steel (AISI 316) water
                                                                                       - 24 hour timer operation for a cylinder heater
     exchangers and differential pressure switch
                                                                                       - control of supplementary heating element
•    Rotary DC inverter compressor, equipped with the crankcase heater and             - outdoor temperature sensor for modulating set point weather compensation
     thermal protection                                                                - heating zone control, single as standard with multiple zone option
•    Condensers finned tubes with copper and aluminium fins high exchange surface      - solar thermal control via optional extension module
     (100% fully quality tested).                                                    • The water circuit comes complete with:
•    Axial variable speed fan, electric motor, housed in an aerodynamic profile with   - variable flow circulation pump for all models
     safety grill                                                                      - differential pressure switch on plant side
•    Remotely positioned low external air temperature device                           - expansion vessel (Heat Pump circuit only)
     - fan speed regulation which maximises efficiency at part load                    - safety valve
                                                                                       - manual filling assembly- pressure gauge- manual air vent valve

NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.



i-KI                                                                                                                                          0031m
Nominal Heating power                                                                       kW            1                                   9.55
Total absorbed power                                                                        kW             2                                  2.31
COP**                                                                                                                                         4.02
Compressor type                                                                                                                               SCROLL INVERTER DC
No. Compressors                                                                             N.                                                1
Refrigerant                                                                                                                                   R410A
No. fans                                                                                    N.                                                1
Fan type                                                                                    3                                                 i-Ci
Plant pump type                                                                             3                                                 i-Ci
Heat pump circuit expansion vessel                                                                                                            Included
Electrical power supply                                                                     V-Ph~Hz                                           230-1~50
Sound power             dB(A)                                                               4-5                                               64
Sound pressure level dB(A)                                                                  4-5                                               50

Dimensions                                                                                                                                    0031m
L                                                                                           mm                                                850
H                                                                                           mm                                                882
D                                                                                           mm                                                330
Operational weight                                                                          kg                                                85


                    BI-VALENT INTEGRATED CONTROL
                    Integrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should the
                    application demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat source
     BI-VALENT
                    subject to appropriate system design.


                    MODULAR CAPABILITY
     MODULAR
                    The i-KI range is designed for modular application to accommodate multi unit larger capacity requirements***.



Note:
1.    Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C
                                                                                                                                                                                                           882




2.    Total input is obtained from compressor input and fan input.
3.    i-Ci= Brushless DC motor
4.    Sound Pressure level according to ISO 9614 and Eurovent 8/1
5.    Average Sound Pressure level above one reflecting surface (Q=2) at 1 metre


                                                                                                                                                                                                            330         850




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
details at point of quotation and/or order.                                                                                                                                                                  Residential Heat Pumps
22
                                                                                                                                                                    HT 65ºC

                                                                                                                 Unit Description                                                HEATING      HOT WATER     MODULAR




                                                                                                                 The DeLonghi AW HT represents the next generation of air source heat
                                                                                                                 pumps with an output temperature of 65ºC. Unlike medium temperature
                                                                                                                 heat pumps these units are able to provide an output of 65ºC in ambient
                                                                                                                 temperatures as low as -12ºC with a minimum operating temperature of
                                                                                                                 -20ºC.

                                                                                                                 • This DeLonghi AW HT range of air source heat pumps provides an
                                                                                                                   extremely high level of performance and a high level of specification
                                                                                                                   which makes them ideal for retrofit applications for both the residential
                                                                                                                   and commercial sectors.


                                                                                                                 • The fact that the installer has to only provide minimal modifications to
                                                                                                                   the existing heating distribution system and hot water cylinder/tank
                                                                                                                   (due to the 65ºC output temperature of the unit) provides significant
                                                                                                                   installation benefits in terms of cost & time on a retrofit or boiler
                                                                                                                   replacement application**.


                                                                                                                 • The nominal refrigeration COP* (efficiency) of these units is very high
                                                                                                                   averaging over 4.15 but importantly the performance of these units in
                                                                                                                   reducing ambient temperatures is also at an extremely high level.


                                                                                                                 • These units incorporate a built in heating system circulation pump,
                                                            ***modular capability                                  control for hot water production including Y Plan valve (optional, not
                                                                                                                   supplied as standard) operation along with full weather compensation
                                                                                                                   and sophisticated controls.
 Unit Summary
 HT UNITS: AW HT                                                                                                 • This advanced control means that these units are able to operate with
 CAPACITY: 10kW-27kW                                                                                               very low system volumes, a minimum open circuit volume of 7 litres
                                                                                                                   per nominal kW of Heat Pump capacity is required which can reduce
 POWER SUPPLY: Single Phase & Three Phase models
                                                                                                                   installation costs considerably. A buffer tank is required to achieve
 These units provide an output temperature of 65ºC for either                                                      maximum operational efficiency in order to provide thermal mass and
 heating or DHW production.                                                                                        efficient defrost capability.

 HIGH EFFICIENCY & PERFORMANCE: COP 4.15 (415% efficient)
                                                                                                                 • DeLonghi-Climaveneta units are high specification heat pumps which
 *Average coefficient of performance (COP) for the AW HT range based on an ambient
 temperature of 7ºC and 35ºC flow temperature                                                                      are built to exacting standards with regard to efficiency and
                                                                                                                   functionality. All the units are European manufactured and benefit from
 COP 3.77 (377% efficient @ 2ºC ambient & 35ºC flow temp)
                                                                                                                   the DeLonghi-Climaveneta approach to product development and
 NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter               quality management providing the complete package that would be
 system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient
 operational performance.
                                                                                                                   expected from a premier manufacturer.

 FEATURES & OPERATIONAL BENEFITS:
                                                                                                                           r HFC     r HFC
                                                                                                                            R-410A    R-410A
 •   MSC accredited heat pumps, certificate HP0005                                                                 AXIAL     AXIAL



 •   Full DHW and heating control
                                                                                                                 *(COP is shown without circulation pump input power. Please note that unlike most other heat
 •   Built in circulation pump                                                                                   pumps these units incorporate built in circulation pumps, therefore by not including the circulation
 •   High COP 4.22                                                                                               pump input power we are able to provide a direct performance comparison with other units).
 •   Pro extended control for high efficiency
 •   Minimum defrost time with a minimum operating temperature of -20°C
 •   65°C operation at -12°C ambient temperature
 **Please note that this unit is capable of providing a maximum output temp of 65°C, the
                                                                                                                  • Microgeneration scheme accreditation allows
 unit will provide this output temperature for heating only at the times of year where it is                        access to grant funding and also guarantees
 necessary. ie: The weather compensation control incorporated within the unit will provide                          performance and manufacturing quality.
 correspondingly lower output temperatures to match external ambient temperatures,                                                                                                     Certificate Number MSC HP0005
 therefore providing a high seasonally corrected Coefficient of Performance.                                                                                                                      Heat Pumps
23

                                                                           HT 65ºC Air Source High Temperature Heat Pumps
 HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION



Main Components
• Housing and base are made from hot-galvanized epoxy powder coated                                                            • Soft start for 230V/1/50Hz units (45 amps)
  sheet metal                                                                                                                  • The water circuit comes complete with:
• High efficiency and low pressure drop stainless steel (AISI 316) water                                                         - circulation pump for all models
  exchangers, with anti-freeze heating element and differential pressure switch                                                  - differential pressure switch on plant side
• High efficiency cycle EVI Hermetic Scroll Compressor (with hot gas direct                                                      - expansion vessel – Heat Pump circuit only
  injection into the compressor) to reach 65°C, with the crankcase heater and                                                    - safety valve
  thermal protection                                                                                                             - manual filling assembly
• Condensers finned tubes with copper and aluminium fins high exchange                                                           - pressure gauge
  surface (100% fully quality tested); sub cooling circuit to prevent the icing at                                             • Remote outside air sensor (wired)
  the basement                                                                                                                 • Remote internal keyboard kit (wired)
• Axial electric fans, external rotor, electric motor with a 6-pole fitted with                                                • The electronic board PRO EXTENDED allows for control of:
  thermal protection, housed in aerodynamic conveyor profile with safety grill                                                   - circulation pump on system side
• A condense collecting tray within water discharge                                                                              - domestic hot water control by external Y Plan three-way valve (accessory)
• Condensing coil protection grills                                                                                              - outdoor temperature sensor for modulating set point weather compensation
NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your supplier for details.

AW HT                                                                                             0031MS            0041MS       0041T       0061T        0071T       0041TS       0061TS      0071TS
Nominal heating power                                                 (1)       kW                10.4              14.9         14.1      19.7           26.6        14.1         19.7        26.6
Total absorbed power                                                  (2)       kW                2.50              3.50         3.30      4.70           6.1         3.30         4.70        6.1
COP                                                                                               4.10              4.12         4.14      4.12           4.26        4.14         4.12        4.26
Heating capacity                                                      (3)       kW                10.4              14.3         14.3      19.7           27.1        14.3         19.7        27.1
Total absorbed power                                                  (2)       kW                3                 4            4         5.60           7.4         4            5.60        7.4
COP                                                                                               3.30              4.48         3.48      3.45           3.58        3.48         3.45        3.58
Heating capacity                                                      (4)       kW                9.10              12.5         12.5      17.5           23.5        12.5         17.5        23.5
Total absorbed power                                                  (2)       kW                2.50              3.30         3.30      4.60           5.9         3.30         4.60        5.9
COP                                                                                               3.44              3.66         3.66      3.72           3.88        3.66         3.72        3.88
Heating capacity                                                      (5)       kW                7.80              11.4         11.4      14.8           21.2        11.4         14.8        21.2
Total absorbed power                                                  (2)       kW                3.80              5.40         5.40      7.60           10.4        5.40         7.60        10.4
COP                                                                                               1.97              2.06         2.06      1.91           1.99        2.06         1.91        1.99
Compressor type                                                                                                                            SCROLL EVI
N. Compressors                                                                  N.                                                         1
Refrigerant                                                                                                                                R407C
N. fans                                                                         N.                2                 2            2         2              3           2            2           3
Plant side pump type                                                  (6)                                                                  Ci
Electrical power supply                                                         V-Ph~Hz           230-1~50          230-1~50     400-3N~50 400-3N~50      400-3N~50   400-3N~50    400-3N~50   400-3N~50
Start-up current                                                                A                 44                45           64        101            99          35           55          99
Sound power                                                           (7)       dB(A)             70                70           70        71             74          70           71          74
Sound pressure                                                        (8)       dB(A)             55                55           55        56             59          55           56          59
Length                                                                          mm                900               900          900       900            1470        900          900         1470
Height                                                                          mm                1240              1390         1390      1390           1700        1390         1390        1700
Width                                                                           mm                420               420          420       420            570         420          420         570
Operational weight                                                              kg                150               160          160       170            320         160          170         320

                   BI-VALENT INTEGRATED CONTROL
                   Integrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should the
                   application demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat source
     BI-VALENT
                   subject to appropriate system design.


                   MODULAR CAPABILITY
     MODULAR
                   The AW HT range is designed for modular application to accommodate multi unit larger capacity requirements***.

                                                                                                                                                                                          L
Note:
1.    Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.
2.    Total input is obtained from compressor input and fan input
3.    Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.
                                                                                                                                                                                                   H
4.    Water in-out 30/35°C (plant side), outdoor air temperature 2°C b.s./ 1°C b.u.
5.    Water 65°C, outdoor air temperature -7°C b.s./ 1°C b.u.
6.    Ci=Circulator; Ce=Centrifugal
7.    Sound power level according to ISO 9614 and Eurovent 8/1
8.    Average sound pressure level above one reflecting surface (Q=2) at 1 meter
      from the outside dimensions of the unit                                                                                                                                                      W




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right
to change update or alter the specification & details of any item shown with or without prior notice for whatever
reason. The information provided within the product guide and/or data sheets is intended for guidance purposes
only, please confirm actual current specification and equipment details at point of quotation and/or order.
                                                                                                                           Commercial Heat Pumps                             Residential Heat Pumps
24
                                                                                                                                                                                   i-NRG

                                                                                                                                                                 HEATING +   COOLING +
                                                                                                                     HEATING
                                                                                                                 HEATING         COOLING
                                                                                                                               COOLING             HOT WATER     HOT WATER   HOT WATER




                                                                                                                 Unit Description
                                                                                                                 • The new 60ºC DeLonghi Professioanl i-NRG Inverter air
                                                                                                                   source heat pump provides exactly the energy required by
                                                                                                                   the distribution system within the property at any time.
                                                                                                                 • The integrated controller accurately follows the actual load of the building
                                                                                                                   utilising a modulating DC inverter source fan and modulating circulation
                                                                                                                   pumps in order to maximise performance.
                                                                                                                 • i-NRG is the new generation heat pump for all year round operation in any
                                                                                                                   operating mode: single cycle (air conditioning, heating, domestic hot water)
                                                                                                                   as well as combined cycle (simultaneous heating or DHW and cooling).
                                                                                                                 • Domestic hot water production is provided by a dedicated heat exchanger
                                                                                                                   for high temperature heat recovery providing partial or 100% free
                                                                                                                   domestic hot water production. The unit can be installed internally
                                                                                                                   (ducted) or externally, ensuring complete flexibility to match the demands
                                                                                                                   of each application.
                                                                                                                 • Designed to operate in ambient temperatures as low as -20ºC the i-NRG
                                                                                                                   range is more than capable of operating with high efficiency in UK & Irish
                                                                                                                   winter temperatures.
                                                                                                                 • The new Climaveneta NADI integrated electronic controller provides a high
                                                                                                                   level of application flexibility and functionality.
                                                                                                                 • The remote keyboard kit with wired indoor and outdoor temperature
                                                                                                                   sensors allows dynamic control of delivered water temperature, this
                                                                                                                   ensures full optimisation of comfort within the property and increases
external                           internal                                                                        overall energy efficiency.
                                                                                                                 + Single heating zone control for radiator, underfloor or fan coil
                                                                                                                 + Multiple heating zone control available via optional expansion module
                                                                                                                 + Solar thermal control via optional extension module
 Unit Summary                                                                                                    + Remote temperature sensor for accurate weather compensated
                                                                                                                   performance
 i-NRG UNITS: Inverter Air Source External or Internal Positioning                                               + Anti-legionella cycle control for DHW cylinder
 CAPACITY: 16.3kW                                                                                                + Bi-valent control for additional heat source
                                                                                                                 • DeLonghi-Climaveneta units are high specification heat pumps which are
 POWER SUPPLY: Single & Three Phase models
                                                                                                                   built to exacting standards with regard to efficiency and functionality. All
 This new generation low noise air source heat pump allows for complete                                            the units are European manufactured and benefit from the DeLonghi-
 flexibility in terms of location (internal or external) and application                                           Climaveneta approach to product development and quality management
                                                                                                                   providing the complete package that would be expected from a premier
 providing heating, cooling and domestic hot water with full heat recovery,
                                                                                                                   manufacturer.
 providing a 60ºC output temperature when operating in -10ºC ambients.

 HIGH EFFICIENCY & PERFORMANCE: COP 3.9 (390% efficient)                                                         Main Accessories
 Coefficient of performance (COP) for the i-NRG range based on an ambient temperature
 of 7ºC and 35ºC flow temperature.                                                                               •    Expansion module for additional heating circuits
                                                                                                                 •    Additional heating zone controllers
 NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter             •    Expansion module for solar thermal collector
 system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient
 operational performance.                                                                                        •    Ducting kit for Internal Positioning

 FEATURES & OPERATIONAL BENEFITS:                                                                                                                      r HFC
                                                                                                                                                        R-410A
                                                                                                                                           AXIAL
 • 60ºC output temperature for heating and/or domestic hot water
 • Low noise 52dBA, when positioned externally or internally
 • Optional ducting kit for internal positioning
 • Twin circuit providing heating or cooling and also DHW outputs                                                • Microgeneration scheme accreditation allows
                                                                                                                   access to grant funding and also guarantees
 • Simultaneous heating and cooling outputs with 100% heat                                                         performance and manufacturing quality.
   recovery                                                                                                                                                                              Certificate Number MSC HP0005
 • Inverter driven providing flexibility in application and performance                                                                                                                             Heat Pumps




                                                                                                                                                                             Residential Heat Pumps
25

                                                                                 i-NRG Air Source High Temperature Heat Pumps
 HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION



Features

• Structure and base coated in hot galvanised epoxy powder coated steel
• DC Inverter Scroll Compressor
• Stainless steel (AISI 316) with high efficiency and low pressure drop plate to plate exchanger
  (domestic hot water side), positioned directly after the compressor ensuring efficient
  domestic hot water production, operating in either full recovery or partial heat recovery.
• Plant side plate heat exchanger stainless steel AISI 316 with high efficiency and low pressure
  drop meets the supply of both hot or cold water for the property. Regardless of the domestic                                                                          Prioritised hot water production in simultaneous DHW & heating mode
  hot water demand the DC inverter scroll compressor will adjust to meet demand.                                                                                             HEATING + DOMESTIC HOT WATER
• Electronic expansion valve and NADI controller
• Finned coils made with copper pipes and aluminium fins with large exchange surface area
  (100% fully quality tested)
• Axial DC Inverter Source Fan housed in aerodynamic conveyor profile with safety grill
• Low external air temperature device provides continuous fan speed regulation via the
  pressure switch
• The water circuit is provided complete with:
  + Variable flow circulating pump plant side
  + Variable flow circulating pump domestic hot water side
  + Expansion tank
  + Safety valve                                                                                                                                                    Partial or 100% heat recovery available in simultaneous cooling & heating mode
  + Pressure gauge
  + Manual filling assembly
                                                                                                                                                                                 HEATING + AIR CONDITIONING
i-NRG                                                                                                                    0061 Single Phase                                           0061 Three Phase
Nominal Heating power                                                                    kW            1                 16.3                                                        16.3
Total absorbed power                                                                     kW            2                 4                                                           4
COP                                                                                                                      3.91                                                        3.94
Cooling capacity                                                                         kW            3                 19.6                                                        19.7
Total absorbed power                                                                     kW            2                 5.4                                                         5.4
EER                                                                                                                      3.62                                                        3.66
Cooling capacity with total recovery                                                     kW            4                 17.9                                                        18
Total absorbed power                                                                     kW            4                 4.9                                                         4.9
Recovery heating capacity                                                                kW            4                 22.6                                                        22.6
Compressor type                                                                                                          SCROLL INVERTER DC
No. Compressors                                                                          N.                              1                                                           1
Refrigerant R410A                                                                        kg                              6.55                                                        6.55
No. fans                                                                                 N.                              1                                                           1
Air Flow                                                                                 m3/h                            8000                                                        8000
Useful head                                                                              Pa                              60                                                          60
Plant side pump type                                                                     5                               i-Ci                                                        i-Ci
Recovery side pump type                                                                  5                               i-Ci                                                        i-Ci
Max system and DHW pressure water side                                                   kPa                             250                                                         250
System and DHW safety valve                                                              kPa                             300                                                         300
Heat pump circuit expansion vessel                                                       l                               10                                                          10
Electrical power supply                                                                  V-Ph~Hz                         230-1~50                                                    400-3N~50
                                                                                                                                                                                                                     1600




Sound power                                                                              dB(A) 6-9                       68                                                          68
Sound pressure level                                                                     dB(A) 7-9                       52                                                          52
Length                                                                                   mm      8                       750                                                         750
Length                                                                                   mm      9                       1535                                                        1535
Height                                                                                   mm                              1600                                                        1600
Width                                                                                    mm                              1050                                                        1050                                                                     1050
System hydraulic connections                                                             inch                            1"1/4                                                       1"1/4                                                750

DHW hydraulic connections                                                                inch                            1"1/4                                                       1"1/4                                               1535
Operational weight                                                                       kg                              260                                                         260


                   BI-VALENT INTEGRATED CONTROL
                   Integrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should the
                   application demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat source
     BI-VALENT
                   subject to appropriate system design.


                   MODULAR CAPABILITY
     MODULAR
                   The i-NRG range is designed for modular application to accommodate multi unit larger capacity requirements***.


Note:
1.    Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C                               5.   i-Ci= Brushless DC pump
2.    Total input is obtained from compressor input and fan input.                                           6.   Sound Pressure level according to ISO 9614 and Eurovent 8/1
3.    Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s.                                   7    Average Sound Pressure level above one reflecting surface (Q=2) at 1 metre
4.    Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side)                          8    Indoor Installation
                                                                                                             9    Outdoor Installation

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided within
the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.
26
                                                                                                                                                              Prana HT

                                                                                                                 Unit Description                                     HEATING       COOLING     HOT WATER     MODULAR




                                                                                                                 The Climaveneta Prana HT range represents the next generation of
                                                                                                                 commercial air source heat pumps with an output temperature of 65ºC.
                                                                                                                 Unlike medium temperature heat pumps these units are able to provide
                                                                                                                 an output of 65ºC in ambient temperatures as low as -12ºC with a
                                                                                                                 minimum operating temperature of -20ºC.

                                                                                                                 • This Climaveneta Prana HT range of air source heat pumps provides an
                                                                                                                   extremely high level of performance and a high level of specification
                                                                                                                   which makes them ideal for either new build or retrofit applications
                                                                                                                   within the commercial sector.

                                                                                                                 • The specifier can choose to carry out a minimal amount of
                                                                                                                   modifications to an existing heating system when applying a 65°C
                                                                                                                   Prana HT to a retrofit application and as a result can potentially achieve
                                                                                                                   significant installation benefits in terms of cost & time savings when
                                                                                                                   replacing existing Oil or Gas fired boilers.

                                                                                                                 • The nominal refrigeration COP* (efficiency) of these units is very high
                                                                                                                   averaging over 4.2 but importantly the performance of these units in
                                                                                       ***modular                  reducing ambient temperatures is also at an extremely high level.
                                                                                         capability
                                                                                                                 • Designed to operate in ambient temperatures as low as -20ºC the Prana
                                                                                                                   HT range is more than capable of operating with high efficiency in UK
 Unit Summary                                                                                                      & Irish winter temperatures.

 MTD UNITS: AW HT                                                                                                • These units incorporate a complete control system for prioritised
 CAPACITY: 40kW-100kW                                                                                              sanitary hot water production along with full weather compensated
                                                                                                                   heating controls. This allows the unit to function efficiently as either a
 POWER SUPPLY: Three Phase models                                                                                  medium or high temperature heat pump with prioritised 65ºC sanitary
                                                                                                                   hot water production (a reversible option for chilled water production
 These units provide heating and hot water up to 65ºC output                                                       is also available).
 temperatures with a reversible cooling option also available.
                                                                                                                 • This advanced control means that these units are able to operate with
 HIGH EFFICIENCY & PERFORMANCE: COP 4.2 (420% efficient)                                                           very low system volumes which reduces buffer tank size and can
                                                                                                                   considerably reduce installation costs.
 *Average coefficient of performance (COP) for the Prana HT range (LN-CA) based on
 EN14511 conditions.
 Average COP 3.6 (360% efficient) @ 7ºC ambient & 45ºC flow temp.
                                                                                                                 • These DeLonghi-Climaveneta units are high specification heat pumps
                                                                                                                   which are built to exacting standards with regard to efficiency and
 NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter
 system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient
                                                                                                                   functionality. All the units are European manufactured and benefit from
 operational performance.                                                                                          the DeLonghi-Climaveneta approach to product development and
                                                                                                                   quality management providing the complete package that would be
 FEATURES & OPERATIONAL BENEFITS:                                                                                  expected from a premier manufacturer.
 •   65°C operation at -12°C ambient temperature
 •   Prioritised 65ºC sanitary hot water production (100% duty)                                                            r HFC     r HFC
                                                                                                                            R-410A    R-410A
 •   Weather compensated heating control (max 65ºC output)                                                         AXIAL     AXIAL



 •   Reversible unit also available
                                                                                                                 *(COP is shown without circulation pump input power. Please note that unlike most other heat
 •   Multiple unit capability for parallel operation                                                             pumps these units incorporate built in circulation pumps, therefore by not including the circulation
 •   High COP 4.20                                                                                               pump input power we are able to provide a direct performance comparison with other units).
 •   MSC accredited heat pumps (relevant models)
 •   Maximum defrost efficiency
 •   Minimum design operating temperature -20°C
                                                                                                                  • Microgeneration scheme accreditation allows
 *Please note that this unit is capable of providing a maximum output temp of 65°C, the
 unit will provide this output temperature for heating only at the times of year where it is
                                                                                                                    access to grant funding and also guarantees
 necessary. ie: The weather compensation control incorporated within the unit will provide                          performance and manufacturing quality.
 correspondingly lower output temperatures to match external ambient temperatures,                                                                                                     Certificate Number MSC HP0005
 therefore providing a high seasonally corrected Coefficient of Performance.                                                                                                                      Heat Pumps
27

                        Prana HT Commercial Air Source High Temperature Heat Pumps
 HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION



Main Components

• Housing and base are made from hot-galvanized epoxy powder coated                                                                       • Axial electric fans, external rotor, electric motor with a 6-pole fitted with
  sheet metal                                                                                                                               thermal protection, housed in aerodynamic conveyor profile with safety grill
• High efficiency and low pressure drop stainless steel (AISI 316) water                                                                  • A condense collecting tray within water discharge
  exchangers, with anti-freeze heating element and differential pressure                                                                  • Outside air sensor wired
  switch
                                                                                                                                          • Remote internal keyboard kit wired (optional)
• High efficiency cycle EVI Hermetic Scroll Compressor (with hot gas direct
                                                                                                                                          • The electronic board PRO EXTENDED allows for control of:
  injection into the compressor) to reach 65°C, with the crankcase heater and
  thermal protection                                                                                                                        - circulation pump on system side
                                                                                                                                            - domestic hot water control by external Y Plan three-way valve (accessory)
• Condensers finned tubes with copper and aluminium fins high exchange
  surface (100% fully quality tested)                                                                                                       - outdoor temperature sensor for modulating set point weather compensation

NB: Optional equipment includes a range of tanks & cylinders plus hydronic kits, see current price list or contact ICS HPT or your distributor for details.


AW HT                                                  0122CA             0122LN-CA                0152CA              0152LN-CA                 0202CA             0202LN-CA                0262CA        0262LN-CA 0302CA     0302LN-CA

Pt                                 (1)    (kW)  37.6                      38.0                     50.6                50.2                      67.9               68.5                     83.7          84.7         100.7   99.0
Pa                                 (1)    (kW)  8.9                       8.9                      12.2                12.1                      16.3               16.4                     19.9          20.0         23.2    23.0
COP                                (1)          4.22                      4.27                     4.15                4.14                      4.17               4.18                     4.21          4.24         4.34    4.30
COP EN14511:3                      (1)          4.21                      4.25                     4.13                4.12                      4.14               4.15                     4.17          4.20         4.30    4.27
Pt                                 (2)    (kW) 38.0                       38.4                     51.3                51.0                      68.8               69.4                     84.9          85.8         102.0   100.3
Pa                                 (2)    (kW) 10.7                       10.7                     14.4                14.3                      19.4               19.4                     23.6          23.7         27.7    27.6
COP                                (2)          3.55                      3.59                     3.57                3.56                      3.55               3.58                     3.60          3.62         3.68    3.63
Pf                                 (3)    (kW) 34.1                       34.0                     43.8                43.8                      60.3               60.2                     76.4          76.2         91.6    90.3
Pa                                 (3)    (kW) 11.5                       11.6                     14.7                15.0                      20.4               20.5                     25.9          26.1         31.3    32.9
EER                                (3)          2.97                      2.93                     2.98                2.93                      2.96               2.94                     2.95          2.92         2.93    2.74
Sound Power level                         dB(A) 84                        80                       86                  82                        87                 83                       87            83           87      84
Sound Pressure Level                      dB(A) 52                        49                       54                  51                        55                 51                       55            51           55      52
Circuits                                        2                         2                        2                   2                         2                  2                        2             2            2       2
Length                                          1695                      1695                     2195                2195                      2745               2745                     2745          2745         2745    2745
Width                                           1120                      1120                     1120                1120                      1120               1120                     1120          1120         1120    1120
Height                                          1420                      1420                     1420                1420                      1420               1420                     1620          1620         1620    1620


                    MODULAR CAPABILITY
   MODULAR
                    The Prana HT range is designed for modular application to accommodate multi unit larger capacity requirements***.



W3000
The W3000 controller offers the latest control and operating functions developed directly by Climaveneta utilising their experience gained within
the field of heat pump design and related plant engineering. The keypad is generously sized with a full operating status display, the controls and
detailed LCD make access to machine settings easy and safe. Temperature regulation with a proportional logic capability is related to the return
water temperature which provides the ability to satisfy simultaneously heating, sanitary hot water and cooling requests with no need for mode
changeover. The diagnostics include full management of alarms with black box function and an alarm recorder for analysis of unit performance.
Monitoring is achieved through either Climaveneta devices or with various options for interfacing to ModBus, Bacnet or Echelon & LonTalk protocols. The controller has the
compatibility to operate with a remote keyboard (single controller management of up to 10 modular units) along with a full time clock function for efficient programming of
operation (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple operational and ambient parameters are incorporated which allow the
unit to reduce the number and duration of the defrost cycles with the benefit of increased overall energy efficiency.




Note:
1. Heating 35ºC flow/7ºC ambient
2. Heating 45ºC flow/7ºC ambient                                                                                                                                                                            H
3. Cooling 12ºC/7ºC 35ºC ambient




                                                                                                                                                                                                                                  w
                                                                                                                                                                                                                       L




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without           Commercial Heat Pumps
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
details at point of quotation and/or order.
28




     GROUND SOURCE
     & GEOTHERMAL
     HEAT PUMPS
     GROUND SOURCE/GEOTHERMAL HEAT PUMPS
              Unit &        Hot        Heating     Simultaneous          Cooling      Simultaneous            Heat      Reduced     Lower    Modular
             Capacity      Water                     Heating/            (Optional)      Cooling,           Recovery     Carbon    Heating
                                                     Hot Water                         Hot Water/                      Emissions     Costs
                                                                                         Heating



           BWR MTD
            5-43kW         HOT WATER     HEATING                           COOLING
             pg 30-31
            Residential




           DHW Twin
            5-40kW                                           HEATING +                          COOLING +
             pg 32-33      HOT WATER     HEATING   HEATING   HOT WATER     COOLING    COOLING   HOT WATER



           Residential &
            Commercial




          Prana MTD
           40-360kW        HOT WATER     HEATING                                                                                              MODULAR
             pg 34-35
            Commercial




          Prana DHW
           40-360kW                                          HEATING +                          COOLING +
                           HOT WATER     HEATING   HEATING   HOT WATER     COOLING    COOLING   HOT WATER                                     MODULAR
             pg 36-37
            Commercial
29




GROUND SOURCE HEAT PUMPS
ICS Heat Pump Technology provides the complete range of
DeLonghi-Climaveneta ground source heat pumps. This range of
units allows the selection of the most efficient ground source heat
pump to match the requirements of each project.


                                                                        GROUND SOURCE HEAT PUMPS
                                                                        Heat energy is collected from the ground at a depth of 1.2 metres
                                                                        using horizontal collectors and is transferred via the heat pump as
                                                                        high grade heat into the building.




GEOTHERMAL HEAT PUMPS
ICS Heat Pump Technology provides the complete range of
DeLonghi-Climaveneta geothermal heat pumps. This range of units
allows the selection of the most efficient geothermal heat pump to
match the requirements of each project.


                                                                        GEOTHERMAL HEAT PUMPS
                                                                        This range of units allows the selection of the most efficient
                                                                        geothermal heat pump to match the requirements of each project.
                                                                        Co-efficient’s of performance in excess of 4.5 (1kW of electrical
                                                                        power gives 4.5kW of heat energy out) can be achieved in the
                                                                        operating conditions experienced within the UK & Ireland.




GROUND COLLECTORS/MANIFOLDS
                                        A full range of ground collectors are provided by ICS-DeLonghi-Climaveneta to
                                        match each ground source/geothermal heat pump range. The package of ground
                                        collector and manifolds is wide ranging encompassing:


                                                                            1. PE or PEX geothermal pipe work
                                                                            2. A complete selection of manifolds
                                                                            3. Ground loop Thermal Fluids incorporating
                                                                               inhibitor & glycol protection
                                                                            4. Ancillary ground source/geothermal
                                                                               equipment & sundry items




                                                            Commercial Heat Pumps                               Residential Heat Pumps
30
                                                                                                                                             BWR-MTD

                                                                                                                                                                                                 HOT WATER
                                                                                                            Unit Description                                        HEATING         COOLING




                                                                                                            The DeLonghi Professional BWR MTD ground source & geothermal heat
                                                                                                            pump ranges are able to provide heating or cooling and domestic hot
                                                                                                            water whilst providing a high level of specification with the benefit of
                                                                                                            value and efficiency.

                                                                                                            • These units incorporate a built in heating system circulation pump,
                                                                                                              a built in source pump to function with horizontal or vertical
                                                                                                              collectors. Full control for hot water production including Y Plan valve
                                                                                                              operation is also incorporated along with full weather compensation
                                                                                                              options, also the units are able to function with any Heat Pump
                                                                                                              optimised thermal store or cylinder.


                                                                                                            • The modulating source pump controls efficiency and maximises the
                                                                                                              performance on part loads by drawing the correct amount of source
                                                                                                              water through the unit to match the load requirement of the
                                                                                                              property at any time.


                                                                                                            • This advanced control means that these units are able to operate
                                                                                                              with very low system volumes, a minimum open circuit volume of
                                                                                                              3.5 litres per nominal kW of Heat Pump capacity is required which
                                                                                                              can remove the need for buffer tanks and secondary pumps hence
     Unit Summary                                                                                             reducing installation costs considerably.

     MTD UNITS: WW/WWR & BW/BWR
                                                                                                            • The high specification standard of the BWR/WWR MTD range
     CAPACITY: 5kW-43kW                                                                                       provides a high specification unit with efficient performance in a
     POWER SUPPLY: Single Phase & Three Phase models                                                          practical and cost effective functional package.

     These units provide heating and hot water up to 55°C with the
                                                                                                            • These DeLonghi-Climaveneta units are high specification heat pumps
     option to also provide heating and cooling.
                                                                                                              which are built to exacting standards with regard to efficiency and
                                                                                                              functionality. All the units are European manufactured and benefit
     HIGH EFFICIENCY & PERFORMANCE:                                                                           from the DeLonghi-Climaveneta approach to product development
     COP 4.28 (428% efficient)                                                                                and quality management providing the complete package that
     BWR MTD source flow temperature 0ºC/-3ºC & output flow temp 35ºC*                                        would be expected from a premier manufacturer.

     COP 5.52 (552% efficient)
                                                                                                                      r HFC     r HFC
     WWR MTD source flow temperature 5ºC/10ºC & output flow temp 35ºC*                                        AXIAL
                                                                                                                       R-410A
                                                                                                                        AXIAL
                                                                                                                                 R-410A

     *Average COP for the BWR & WWR MTD ranges
     NOTE. Actual system efficiency (COP) and annual performance will depend on the                         *(COP is shown without circulation pump input power. Please note that unlike most
     distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed   other heat pumps these units incorporate built in circulation pumps, therefore by not
     in order to provide efficient operational performance.                                                 including the circulation pump input power we are able to provide a direct performance
                                                                                                            comparison with other units).
     FEATURES & OPERATIONAL BENEFITS:
     •   MSC accredited heat pumps, certificate HP0005
     •   Full DHW and heating control
     •   Heating only or reversible Heat Pump                                                               • Microgeneration scheme accreditation allows
     •   Built in plant and circulation pump                                                                  access to grant funding and also guarantees
                                                                                                              performance and manufacturing quality.
     •   High value and high performance
                                                                                                                                                                              Certificate Number MSC HP0005
     •   55ºC output temperature                                                                                                                                                         Heat Pumps




                                                                                                                                                            Residential Heat Pumps
31

                                                                BWR-MTD Ground Source & Geothermal Heat Pumps


Main Components
• Housing and base are made from hot-galvanized epoxy powder coated sheet metal                                                         - pressure gauge
• Case panels are insulated within low noise material for further improvement of                                                        - manual air vent valve
  silence                                                                                                                             • Heat exchangers on the system and source side are brazed plate models in AISI
• Hermetic scroll compressors with oil sump heater and electronic overheating                                                           316 stainless steel providing high efficiency and a low pressure drop, complete
  protection with centralised manual reset                                                                                              with vapour barrier closed-cell heat insulation
• The water circuit is complete with:                                                                                                 • Soft start for 230V/1/50Hz (45 amps)
  - variable flow water pump (system side) & variable flow source pump                                                                • The electronic menu allows control of:
  - source side modulating valve for models WWR (water source units), this will                                                         - plant and Geothermal ground circuits (BWR) / modulating valve (WWR)
    switch off the water flow whenever the compressor is not in operation.                                                              - domestic hot water production by control of an external three-way valve (Y Plan)
  - differential pressure switch on source side and system side                                                                         - a zone of direct heating
  - expansion vessel (Heat Pump circuit only)                                                                                           - external heating source
  - safety valve                                                                                                                        - weather compensation (sensor is accessory)
  - manual filling assembly
NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.

  BWR MTD                                                                 0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121
                                                                          MS   MS   MS   MS   MS   T    T    T    T    T    T    T    T    T    T
  Nominal heating power                             (1) kW                5.40         5.90        7.30         9.20        11.7         5.90        7.50        9.10         12.2        13.7         16          19.8         23          26.5         33.3
  Total absorbed power                              (2) kW                1.34         1.50        1.82         2.35        2.80         1.40        1.74        2.10         2.80        3.40         3.50        4.40         4.90        5.80         7.30
  COP *                                                                   4.03         3.93        4            3.92        4.18         4.21        4.31        4.33         4.36        4.03         4.57        4.50         4.69        4.57         4.56
  Cooling capacity                                  (3) kW                7.10         7.60        9.80         12          15.1         7.60        9.50        12           15.7        18           21.3        26.9         30.7        34.8         44.8
  Total absorbed power                              (2) kW                1.60         1.70        1.96         2.53        3.27         1.60        1.84        2.50         3.30        3.70         4.10        5.15         5.95        7            8.80
  EER *                                                                   4.44         4.47        5            4.74        4.62         4.75        5.16        4.80         4.76        4.86         5.20        5.22         5.16        4.97         5.09
  Heating capacity                                  (4) kW                5.20         5.70        7.10         9           11.3         5.70        7           8.70         11.8        12.9         15.2        18.8         21.8        25.1         31.9
  Total absorbed power                              (2) kW                1.70         1.90        2.30         3           3.60         1.90        2.20        2.70         3.70        4.10         4.40        5.60         6.20        7.40         9
  COP *                                                                   3.06         3           3.09         3           3.14         3           3.18        3.22         3.19        3.15         3.45        3.36         3.52        3.39         3.54
  Cooling capacity                                  (5) kW                5.20         5.60        7.20         8.80        11.3         5.60        7.30        8.90         11.8        13.2         15.7        19.8         22.9        26           33.4
  Total absorbed power                              (2) kW                1.53         1.70        2            2.60        3.20         1.63        1.90        2.41         3.19        3.80         4           5.10         5.80        6.80         8.40
  EER *                                                                   3.40         3.29        3.60         3.38        3.53         3.44        3.84        3.69         3.70        3.47         3.93        3.88         3.95        3.82         3.98
  ESEER                                                                   4.03         3.73        4.26         3.95        3.90         3.97        4.54        4.33         4.08        3.92         4.51        4.40         4.61        4.33         4.37
  Compressor type                                                                                                                                    SCROLL
  N. Compressors                                           N.                                                                                        1
  Refrigerant                                                                                                                                        R410A
  Plant side pump type                              (6)                   Ci           Ci          Ci     Ci                Ci           Ci          Ci          Ci           Ci          Ci     Ci                Ce           Ce          Ce           Ce
  Source side pump type                             (6)                   Ci           Ci          Ci     Ci                Ce           Ci          Ci          Ci           Ce          Ce     Ce                Ce           Ce          Ce           Ce
  Electrical power supply                               V-Ph~Hz                                    230-1~50                                                                               400-3N~50
  Start-up current                                      A       26                     27          37     44                59           32          35          48           64          64     75                95           111         118          140
  Sound power                                       (7) dB(A)   52                     52          53     53                58           52          52          52           58          58     59                66           66          70           70
  Sound pressure                                    (8) dB(A)   38                     38          39     39                44           38          38          38           44          44     45                51           51          55           55
  Length                                            mm          560                    560         560    560               560          560         560         560          560         560    560               680          680         680          680
  Height                                            mm          980                    980         980    980               980          980         980         980          980         980    980               1150         1150        1150         1150
  Width                                             mm          575                    575         575    575               575          575         575         575          575         575    575               780          780         780          780
  Operational weight                                kg          148                    148         150    152               160          148         150         152          160         170    175               220          230         235          25


  WWR MTD                                                                 0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121
                                                                          M    M    M    M    M    T    T    T    T    T    T    T    T    T    T
  Nominal Cooling capacity                          (1) kW                5.20         5.60        7.20         8.80        11.3         5.60        7.30        8.90         11.8        13.2         15.7        19.8         22.9        26           33.4
  Total power input                                 (1) kW                1.50         1.70        2            2.60        3.20         1.60        1.90        2.40         3.20        3.80         4           5.10         5.80        6.80         8.40
  EER                                                                     3.47         3.29        3.60         3.38        3.53         3.50        3.84        3.71         3.69        3.47         3.93        3.88         3.95        3.82         3.98
  ESEER                                                                   4.03         3.73        4.26         3.95        3.90         3.81        4.39        4.17         4.08        4.02         4.51        4.40         4.61        4.33         4.37
  Water flow rate plant side                        (1) m3/h              0.90         1           1.20         1.50        1.90         1           1.30        1.50         2           2.30         2.70        3.40         3.90        4.50         5.70
  Heating capacity                                  (2)                   6.80         7.50        9.20         11.6        14.6         7.40        9.20        11.4         15.3        17.1         20          24.8         28.8        33           41.7
  Total absorbed power                              (2) kW                1.70         1.90        2.30         3           3.60         1.90        2.20        2.70         3.70        4.20         4.60        5.80         6.40        7.60         9.50
  COP                                                                     4            3.95        4            3.87        4.06         3.89        4.18        4.22         4.14        4.07         4.35        4.28         4.50        4.34         4.39
  Water flow rate plant side                        (2)                   1.20         1.30        1.60         2           2.50         1.30        1.60        2            2.60        2.90         3.40        4.30         5           5.70         7.20
  Absorbed current                                         A              7.50         8           8.90         12.3        15.6         4.60        5           6.10         7.40        8.10         8.80        12.2         13.4        16.1         19.2
  Operational weight                                       kg             148          148         150          152         160          148         150         152          160         170          175         220          230         235          250
  Compressor type                                                                                                                                    SCROLL
  Refrigerant                                                                                                                                        R410A
  Hydraulic connections                                 inches            G3/4”        G3/4”       G3/4” G3/4”              G1”1/4 G3/4”             G3/4”       G3/4”        G1”1/4 G1”1/4 G1”1/4                 G1”1/4 G1”1/4 G1”1/4 G 1”1/4
  Sound pressure level                              (3) dB(A)             41           41          42     42                47     41                42          42           47     47     48                     55     55     59     59
  Sound power                                           dB(A)             52           52          53     53                58     52                53          53           58     58     59                     66     66     70     70
  Electrical power supply                               V-Ph~Hz                                    230V~50Hz                                                                         400V-3N~50Hz
  Length                                                mm                560          560         560    560               560          560         560         560          560    560    560                    680          680         680          680
  Height                                                mm                980          980         980    980               980          980         980         980          980    980    980                    1150         1150        1150         1150
  WIdth                                                 mm                575          575         575    575               575          575         575         575          575    575    575                    780          780         780          780


  Note: BWR MTD                                                                                                                     Note: WWR MTD
  1.  Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side)                                     1. Evaporator water (in/out) = 12/7°C, condenser water
  2.  According to Eurovent                                                                                                            (in/out) = 30/35°C, based on Eurovent Standard
  3.  Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)                                    2. Evaporator water (in/out), 10/5°C, condenser water
  4.  Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side)                                        (in/out) 40/45°C, based on Eurovent standard
                                                                                                                                    3. Sound pressure measured at 1 m in open field conditions                              D
  5.  Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)
  6.  Ci=Circulator; Ce=Centrifugal
  7.  Sound power level according to ISO 9614 and Eurovent 8/1
  8.  Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside
      dimensions of the unit.
   *According to the Eurovent standard without circulation pump input power.                                                                                                                                                                                w
                                                                                                                                                                                                                                           L
ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided within
the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.
32
                                                                                                                                                                                              DHW Twin
                                                                                                                                              WITH HEAT RECOVERY
                                                                  HEATING +        COOLING +
                HEATING
            HEATING              COOLING
                               COOLING           HOT WATER        HOT WATER        HOT WATER                                                  Unit Description
                                                                                                                                              The DeLonghi Professional BWR DHW are a unique range of commercial ground
                                                                                                                                              or water source heat pumps which are capable of providing a high efficiency
                                                                                                                                              combination of output conditions:
                                                                                                                                              •   Heating only
                                                                                                                                              •   Simultaneous heating and hot water to 55ºC.
                                                                                                                                              •   Hot water only
                                                                                                                                              •   Cooling only
                                                                                                                                              •   Simultaneous cooling and hot water with up to 100% heat recovery
                                                                                                                                              •   Simultaneous cooling and heating with up to 100% heat recovery
                                                                                                                                              • These units can be specified to suit a particular application and due to their
                                                                                                                                                ability to provide two simultaneous outputs they are able to provide real
                                                                                                                                                benefits on both residential and commercial applications.
                                                                                                                                              • Within the commercial sector these heat pumps provide flexibility and real
                                                                                                                                                environmental benefits. As an alternative to conventional VRF systems
                                                                                                                                                these units remove all of the refrigerant from within a building and
                                                                                                                                                therefore significantly remove the potential for refrigerant leakage
     Unit Summary                                                                                                                               therefore complying completely with the objectives of the F Gas regulations.
                                                                                                                                              • Also when operating on a split heating/hot water and air conditioning load
     DHW TWIN UNITS: WW/WWR & BW/BWR                                                                                                            these heat pumps will provide up to 100% heat recovery which then
     CAPACITY: 5kW-40kW                                                                                                                         benefits the user with free heating or hot water.
     POWER SUPPLY: Single Phase & Three Phase models                                                                                          • A growing demand for energy and heat recovery has created a highly
                                                                                                                                                efficient requirement to use these units to recover waste energy from waste
     These units provide simultaneous supplies of domestic hot water                                                                            water or fluid flows, recovering energy from cooling towers or waste water
     and heating/air conditioning.                                                                                                              flows is easily achievable when utilising these units in heat recovery
                                                                                                                                                specification.
     HIGH EFFICIENCY & PERFORMANCE:
     COP 3.56 (356% efficient)                                                                                                                • Also these heat pump units will provide up to 100% duty on either primary
                                                                                                                                                or secondary heat exchangers along with the ability to provide a
     BWR DHW source flow temperature 0ºC/-3ºC & output flow temp 35ºC*
                                                                                                                                                combination of load capability heating and hot water simultaneously or
     COP 4.57 (457% efficient)                                                                                                                  heating and cooling simultaneously with up to 100% heat recovery. This
     WWR DHW source flow temperature 5ºC/10ºC & output flow temp 35ºC*                                                                          allows the heat pump units to provide this simultaneous output feature to
                                                                                                                                                manage seasonal heating and cooling loads from the same heat pump unit.
     *Average COP for the BWR & WWR DHW ranges
                                                                                                                                              • These DeLonghi-Climaveneta units are high specification heat pumps which
     NOTE. Actual system efficiency (COP) and annual performance will depend on the
     distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed
                                                                                                                                                are built to exacting standards with regard to efficiency and functionality. All
     in order to provide efficient operational performance.                                                                                     the units are European manufactured and benefit from the DeLonghi-
                                                                                                                                                Climaveneta approach to product development and quality management
     FEATURES & OPERATIONAL BENEFITS:                                                                                                           providing the complete package that would be expected from a premier
     • Fully self-contained unit – no external refrigerant pipes                                                                                manufacturer.
     • Incorporates source and circulation pumps as standard
     • Highly efficient and flexible design with easy to use controls                                                                                         r HFC       r HFC
                                                                                                                                                               R-410A      R-410A
     • Heating, cooling and domestic hot water provided                                                                                             AXIAL        AXIAL


     • Suitable for large capacity hot water users and simultaneous                                                                           *(COP is shown without circulation pump input power. Please note that unlike most other heat
       heating & air conditioning applications                                                                                                pumps these units incorporate built in circulation pumps, therefore by not including the circulation
                                                                                                                                              pump input power we are able to provide a direct performance comparison with other units).


     Note:

                                                          1. Heating mode: Plant side inlet water temperature at 30°C and outlet at 35°C, Source side inlet water temperature at 10°C and outlet at 5°C
                                                          2. Operation recovery plant side inlet water temperature at 45°C and outlet at 50°C, Source side inlet water temperature at 10°C and outlet at 5°C
                                                          3. Cooling mode: Plant side inlet water temperature at 23°C and outlet at 18°C, Source side inlet water temperature at 30°C and outlet at 35°C
                                                          4. Cooling mode: Plant side inlet water temperature at 12°C and outlet at 7°C, Source side inlet water temperature at 30°C and outlet at 35°C
       D                                                  5. Heating mode: Plant side inlet water temperature at 30°C and outlet at 35°C, Source side inlet water temperature at 0°C and outlet at -3°C (Gly 25%)
                                                          6. Funzionamento in recupero: Plant side inlet water temperature at 45°C and outlet at 50°C, Source side inlet water temperature at 0°C and outlet at -3°C (Gly 25%)
                                                          7. Standard unit data - DHW/S model with soft starter for 230V/1/50Hz
                                                          8. Sound pressure at 1 meter distance from the external surface of the unit, free field.
                                                          *According to the Eurovent standard without circulation pump input power.

                    L                w

                                                                                                                                                                                                            Residential Heat Pumps




                                                                                                                                                                                                            Commercial Heat Pumps
 ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without
 prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
 details at point of quotation and/or order.
33

                                              DHW Twin Ground Source & Geothermal Heat Pumps

Main Components
•  Housing and base are made from hot-galvanized epoxy powder coated sheet metal
•  Case panels are insulated within low noise material for noise reduction
•  Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection
•  Primary stainless steel (AISI 316) plate heat exchanger with high efficiency and low pressure drop (providing domestic hot
   water or heating)
• When combined with the secondary heat exchanger (cooling duty) these units will provide either full or partial heat recovery
• High efficiency and low pressure drop stainless steel (AISI 316) source side plate heat exchanger for efficient heat transfer
                                                                                                                                        Prioritised hot water production in simultaneous DHW & heating mode
   and maximum performance.
• The water circuit comes complete with:                                                                                                   HEATING + DOMESTIC HOT WATER
   - Primary heat exchanger circulation pump for domestic hot water or heating circuit
   - Secondary heat exchanger circulation pump for heating or cooling circuit
   - Ground source/Geothermal pump for the BWR model
   - differential pressure switch on source side and system side
   - expansion vessel (Heat Pump circuit only)
   - safety valve (6 bar)
   - manual filling assembly
   - pressure gauge
   - venting and draining valve
• Soft start for 230V/1/50Hz units - WWR BWR DHW/S
                                                                                                                                   Partial or 100% heat recovery available in simultaneous cooling & heating mode
NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact
ICS HPT or your distributor for details.packs, see current price list or contact ICS HPT or your distributor for details.                     HEATING + AIR CONDITIONING
    BWR DHW                                             0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121
                                                        MS   MS   MS   MS   MS   T    T    T    T    T    T    T    T    T    T
    Nominal heating power              (1) kW           4.50     5.70     6.70      7.80     9.70      5.60     6.60     7.70      9.50        11.4       13.9      18.8       21.2       24.4       29.7
    Total absorbed power               (2) kW           1.30     1.60     1.90      2.30     2.80      1.60     1.90     2.20      2.70        3.20       3.70      5.10       5.60       6.60       8.30
    COP                                                 3.44     3.45     3.48      3.39     3.51      3.50     3.51     3.44      3.56        3.57       3.72      3.70       3.81       3.72       3.57
    Cooling capacity                   (3) kW           7.30     9.20     11        12.5     15.3      9.20     10.9     12.4      15.4        19.1       22.5      30.2       34.4       38.9       49.7
    Total absorbed power               (2) kW           1.30     1.70     2         2.40     2.90      1.60     1.90     2.30      2.80        3.60       4.10      5.50       6.10       7.30       9.30
    EER                                                 5.62     5.41     5.50      5.21     5.28      5.75     5.74     5.39      5.50        5.31       5.49      5.49       5.64       5.33       5.34
    Total absorbed power               (4) kW           6        7.80     9.20      10.3     12.9      7.70     9.10     10.3      13.1        16         18.9      25.5       29         32.7       41.1
    Total absorbed power                   kW           1.90     2.40     2.90      3.40     4.20      2.30     2.80     3.30      4           4.90       5.70      7.70       8.40       10.2       12.8
    Recovery heating capacity          (4) kW            7.90    10       11.9      13.5     16.8      9.90     11.7     13.4      16.9        20.6       24.2      32.7       36.9       42.4       53.1
    Heating capacity                   (5) kW           4.30     5.50     6.60      7.70     9.40      5.40     6.50     7.50      9.30        11.1       13.3      17.9       20.5       23.5       28.4
    Total absorbed power               (2) kW           1.70     2.10     2.50      3        3.50      2        2.40     2.90      3.40        4          4.70      6.50       7          8.30       10.5
    COP                                                 2.60     2.63     2.64      2.59     2.69      2.67     2.67     2.63      2.75        2.78       2.86      2.77       2.95       2.84       2.69
    Cooling capacity                   (6) kW           5.10     6.50     7.70      8.90     11        6.50     7.70     8.80      10.9        13.4       16.1      21.7       24.6       28         34.8
    Total absorbed power               (2) kW           1.30     1.70     2         2.40     2.90      1.70     2        2.30      2.80        3.40       4         5.40       5.90       7          8.90
    EER                                                 3.92     3.82     3.85      3.71     3.79      3.82     3.85     3.83      3.89        3.94       4.03      4.02       4.17       4.00       3.91
    Compressor type                                                                                             SCROLL
    N. Compressors                           N.                                                                 1
    Refrigerant                                                                                                 R407C
    Plant side pump type               (7)              Ci       Ci       Ci     Ci          Ci        Ci       Ci       Ci        Ci          Ci     Ci            Ce         Ce         Ce         Ce
    Recovery side pump type            (7)              Ci       Ci       Ci     Ci          Ci        Ci       Ci       Ci        Ci          Ci     Ci            Ci         Ci         Ci         Ci
    Source side pump type              (7)              Ci       Ci       Ci     Ci          Ce        Ci       Ci       Ci        Ce          Ce     Ce            Ce         Ce         Ce         Ce
    Electrical power supply                V-Ph~Hz                        230-1~50                                                             400-3N~50
    Start-up current                       A            21       27       34     45          51        32       40       46        50          66     74            95         111        118        140
    Sound power                        (8) dB(A)        52       52       53     53          58        52       52       52        58          58     59            66         66         70         70
    Sound pressure                     (9) dB(A)        38       38       39     39          44        38       38       38        44          44     45            51         51         55         55
    Length                                 mm           560      560      560    560         560       560      560      560       560         560    560           680        680        680        680
    Height                                 mm           980      980      980    980         980       980      980      980       980         980    980           1150       1150       1150       1150
    Width                                  mm           575      575      575    575         575       575      575      575       575         575    575           780        780        780        780
    Operational weight                     kg           188      188      190    195         215       188      190      195       215         228    233           260        270        280        305

    WWR DHW                                             0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121
                                                        MS   MS   MS   MS   MS   T    T    T    T    T    T    T    T    T    T
    Nominal heating power              (1) kW           6        7.60     9         10.5     12.9      7.50     8.90     10.3      12.7        15.6       18.7      25.3       28.4       32.6       40.5
    Total absorbed power               (2) kW           1.30     1.70     2         2.40     2.90      1.70     2        2.30      2.80        3.40       3.90      5.30       5.90       6.90       8.80
    COP                                                 4.49     4.48     4.51      4.36     4.50      4.55     4.58     4.44      4.57        4.58       4.75      4.73       4.84       4.69       4.59
    Cooling capacity                   (3) kW           7.30     9.20     11        12.5     15.3      9.20     10.9     12.4      15.4        19.1       22.5      30.2       34.4       38.9       49.7
    Total absorbed power               (2) kW           1.30     1.70     2         2.40     2.90      1.60     1.90     2.30      2.80        3.60       4.10      5.50       6.10       7.30       9.30
    EER                                                 5.62     5.41     5.50      5.21     5.28      5.75     5.74     5.39      5.50        5.31       5.49      5.49       5.64       5.33       5.34
    Total absorbed power               (4) kW           6        7.80     9.20      10.3     12.9      7.70     9.10     10.3      13.1        16         18.9      25.5       29         32.7       41.1
    Total absorbed power                   kW           1.90     2.40     2.90      3.40     4.20      2.30     2.80     3.30      4           4.90       5.70      7.70       8.40       10.2       12.8
    Recovery heating capacity          (4) kW           7.90     10       11.9      13.5     16.8      9.90     11.7     13.4      16.9        20.6       24.2      32.7       36.9       42.4       53.1
    Heating capacity                   (5) kW           5.60     7.20     8.50      9.90     12.2      7.20     8.60     9.90      12.3        14.9       17.9      24         27.1       31.1       38.3
    Total absorbed power               (2) kW           1.70     2.20     2.60      3.10     3.60      2.10     2.50     3         3.50        4.30       4.90      6.80       7.30       8.70       11.1
    COP                                                 3.33     3.35     3.37      3.28     3.40      3.41     3.42     3.34      3.48        3.50       3.62      3.55       3.69       3.55       3.45
    Cooling capacity                   (6) kW           5.10     6.50     7.70      8.90     11        6.50     7.70     8.80      10.9        13.4       16.1      21.7       24.6       28         34.8
    Total absorbed power               (2) kW           1.30     1.70     2         2.40     2.90      1.70     2        2.30      2.80        3.40       4         5.40       5.90       7          8.90
    EER                                                 3.92     3.82     3.85      3.71     3.79      3.82     3.85     3.83      3.89        3.94       4.03      4.02       4.17       4.00       3.91
    Compressor type                                                                                             SCROLL
    N. Compressors                           N.                                                                 1
    Refrigerant                                                                                                 R407C
    Plant side pump type               (7)              Ci       Ci       Ci     Ci          Ci        Ci       Ci       Ci        Ci          Ci     Ce            Ce         Ce         Ce         Ce
    Recovery side pump type            (7)              Ci       Ci       Ci     Ci          Ci        Ci       Ci       Ci        Ci          Ci     Ci            Ci         Ci         Ci         Ci
    Electrical power supply                V-Ph~Hz                        230-1~50                                                             400-3N~50
    Start-up current                       A            21       27       34     45          51        32       40       46        50          66     74            95         111        118        140
    Sound power                        (8) dB(A)        52       52       53     53          58        52       52       52        58          58     59            66         66         70         70
    Sound pressure                     (9) dB(A)        38       38       39     39          44        38       38       38        44          44     45            51         51         55         55
    Length                                 mm           560      560      560    560         560       560      560      560       560         560    560           680        680        680        680
    Height                                 mm           980      980      980    980         980       980      980      980       980         980    980           1150       1150       1150       1150
    Width                                  mm           575      575      575    575         575       575      575      575       575         575    575           780         780       780        780
    Operational weight                     kg           188      188      190    195         215       188      190      195       215         228    233           260        270        280        305
34
                                                                                                               Prana BWR-MTD

                                                                                                                                                              HEATING      COOLING     HOT WATER     MODULAR




                                                                                                           REVERSIBLE HEAT PUMP FOR INDOOR INSTALLATION
                                                                                                           40KW - 360KW
                                                                                                           Unit Description
                                                                                                           • Optimised internally positioned heat pump unit with optional chilled
                                                                                                             water production, a complete range is available from 40kW-360kW
                                                                                                             operating through varying source temperature ranges to facilitate either
                                                                                                             ground source or water source operation.
                                                                                                           • The range includes single-circuit/two-compressor versions and also twin
                                                                                                             circuit/four compressor versions for larger output capacity. This
                                                                                                             configuration provides excellent load management capability which gives
                                                                                                             high performance and efficiency along with associated contingency
                                                                                                             benefits and redundancy.
                                                                                                           • The use of R410A enables the unit to operate with high efficiency and
                                                                                                             performance whilst remaining flexible in operation.
                                                                                                           • Climaveneta has designed the Prana BWR MTD 0152-1204 units to be
                                                                                                             configured with a range of optional accessories for ease of operation when
                                                                                                             specified across a range of differing applications from ground water source
                                                                                                             to higher temperature heat recovery from process or production waste
                                                                                                             water.
                                                                                                           • The built-in hydronic module includes the main water circuit components;
                                                                       ***modular capability                 it is available in various configurations with one or two pumps with high
                                                                                                             or low head both on the evaporator and the condenser side.
     Unit Summary                                                                                          • The W3000 controller provides integrated single unit control but also allows
                                                                                                             parallel operation of up to 5 units of varying capacity. This allows a
     PRANA BWR MTD UNITS: WW/WWR & BW/BWR                                                                    completely bespoke system to be configured to match the demands of
                                                                                                             larger applications.
     CAPACITY: 40kW-360kW
     POWER SUPPLY: Three Phase models                                                                      • The Prana BWR range is also able to connect either singularly or a multi
                                                                                                             unit modular basis with ModBus/Echelon/Bacnet protocol cards for BMS
     These units provide a heating output to 55°C with the option to                                         compatability
     also provide cooling with a reversible configuration.
                                                                                                           • These DeLonghi-Climaveneta units are high specification heat pumps
                                                                                                             which are built to exacting standards with regard to efficiency and
     HIGH EFFICIENCY & PERFORMANCE:
                                                                                                             functionality. All the units are European manufactured and benefit from
     COP 4.1 (410% efficient)*                                                                               the DeLonghi-Climaveneta approach to product development and quality
     *BWR MTD source flow temperature 0ºC/-3ºC & output flow temp 35ºC                                       management providing the complete package that would be expected
     COP 5.06 (506% efficient)*                                                                              from a premier manufacturer.
     *WWR MTD source flow temperature 5ºC/10ºC & output flow temp 35ºC                                     • The Prana HT range is designed for modular application to accommodate
     *Average COP for the Prana BWR & WWR MTD ranges                                                         larger capacity requirements***.

     NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter
     system utilised. Care should be taken to ensure that the heat pump is installed in order to provide
     efficient operational performance.                                                                    W3000
                                                                                                           The W3000 controller offers the latest control and operating
     FEATURES & OPERATIONAL BENEFITS:                                                                      functions developed directly by Climaveneta utilising their
     •   Full DHW and heating control                                                                      experience gained within the field of heat pump design and related
                                                                                                           plant engineering. The keypad is generously sized with a full
     •   Heating only or reversible heat pump                                                              operating status display, the controls and detailed LCD make access
     •   Built in plant and circulation pump                                                               to machine settings easy and safe. Temperature regulation with a proportional logic capability
                                                                                                           is related to the return water temperature which provides the ability to satisfy simultaneously
     •   High value and high performance
                                                                                                           heating, sanitary hot water and cooling requests with no need for mode changeover. The
     •   55ºC output temperature                                                                           diagnostics include full management of alarms with black box function and an alarm recorder for
     •   Modular control for multiple unit configuration                                                   analysis of unit performance. Monitoring is achieved through either Climaveneta devices or with
                                                                                                           various options for interfacing to ModBus, Bacnet or Echelon & LonTalk protocols. The controller
     •   Compact footprint for plant room positioning                                                      has the compatibility to operate with a remote keyboard (single controller management of up
                                                                                                           to 10 modular units) along with a full time clock function for efficient programming of operation
                                                                                                           (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple
                                                                                                           operational- and ambient parameters are incorporated which allow the unit to reduce the number
                                                                                                           and duration of the defrost cycles with the benefit of increased overall energy efficiency.
35

                                          Prana BWR-MTD Ground Source & Geothermal Heat Pumps


       BWR-MTD                                                                              0152              0182             0202             0252             0262             0302             0352        0412       0452   0512
       Cooling capacity                                             (1)       kW            43.4              50.1             58.9             66.4             72.6             86.7             101         115        129    144
       Total power input                                            (1)       kW            10.0              11.3             13.0             15.2             16.6             19.5             22.7        25.9       28.9   32.2
       Condenser heating capacity                                   (1)                     5.8               60.7             71.2             80.7             88.2             105              123         139        156    174
       EER                                                                                  4.34              4.43             4.53             4.37             4.37             4.45             4.46        4.43       4.45   4.46
       ESEER                                                                                5.80              6.00             6.00             5.70             5.60             5.70             5.80        5.70       5.80   5.80
       Heating capacity                                             (2)       kW            50.5              58.2             68.0             77.0             85.0             101              117         132        148    165
       Total power input                                            (2)       kW            12.9              14.3             16.7             19.2             21.1             24.7             28.7        32.2       36.0   40.0
       COP                                                          (2)                     3.91              4.07             4.07             4.01             4.03             4.09             4.07        4.10       4.12   4.14
       No. Compressors/No. Circuits N.                                                      2/1               2/1              2/1              2/1              2/1              2/1              2/1         2/1        2/1    2/1
       Sound power                                                  (3)       dB(A) 73                        74               74               74               75               76               77          77         78     78
       Sound pressure                                               (4)       dB(A)
       Length                                                       (5)       mm            1055              1055             1055             1055             1055             1222             1222        1222       1222   1222
       Width                                                        (5)       mm            649               649              649              649              649              843              843         843        843    843
       Height                                                       (5)       mm            1255              1255             1255             1255             1255             1496             1496        1496       1496   1496
       Operating weight                                             (5)       kg            290               305              315              325              330              585              605         660        685    740


       BWR-MTD                                                                              0552              0612             0604             0704             0804             0904             1004        1104       1204
       Cooling capacity                                             (1)       kW            165               186              174              203              228              258              288         329        371
       Total power input                                            (1)       kW            36.9              41.6             38.9             45.2             51.6             58.0             64.0        74.0       83.5
       Condernser heating capacity                                  (1)                     200               225              211              245              276              312              348         398        450
       EER                                                                                  4.47              4.48             4.47             4.48             4.42             4.45             4.50        4.44       4.44
       ESEER                                                                                5.90              5.80             5.80             5.90             5.80             5.90             5.90        6.00       5.90
       Heating capacity                                             (2)       kW            190               215              202              234              263              297              332         379        428
       Total power input                                            (2)       kW            45.9              51.8             49.2             56.6             64.1             72.1             79.5        91.9       104
       COP                                                          (2)                     4.14              4.14             4.11             4.13             4.10             4.12             4.17        4.13       4.12
       No. Compressors/No. Circuits N.                                                      2/1               2/1              4/2              4/2              4/2              4/2              4/2         4/2        4/2
       Sound power                                                  (3)       dB(A) 79                        79               86               87               88               89               90          91         91
       Sound pressure                                               (4)       dB(A)
       Length                                                       (5)       mm            1222              1222             2227             2227             2227             2227             2227        2227       2227
       Width                                                        (5)       mm            873               873              877              877              877              877              877         877        877
       Height                                                       (5)       mm            1496              1496             1780             1780             1780             1780             1780        1780       1780
       Operating weight                                             (5)       kg            790               830              1090             1165             1245             1290             1395        1500       1585



                             MODULAR CAPABILITY
           MODULAR
                             The Prana BWR MTD range is designed for modular application to accommodate multi unit larger capacity requirements***.



                  r HFC         r HFC
                   R-410A        R-410A
         AXIAL       AXIAL




       Note:
       1. Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard.
       2. Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.
       3. Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for                                                                                                   D
          Eurovent certified units; in compliance with ISO 3744 for non-certified units.
       4. Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on
          longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.
       5. Unit in standard configuration/execution, without optional accessories.

                                                                                                                                                                                                                      L          W




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without           Commercial Heat Pumps
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
details at point of quotation and/or order.
36
                                                                                                           Prana BWR-DHW

                                                                                                                                             HEATING      COOLING      HOT WATER    MODULAR




                                                                                                           REVERSIBLE HEAT PUMP WITH TOTAL HEAT RECOVERY
                                                                                                           40KW - 360KW

                                                                                                           Unit Description

                                                                                                           The DeLonghi Prana BWR DHW are a unique range of commercial ground or
                                                                                                           water source heat pumps which are capable of providing a high efficiency
                                                                                                           combination of output conditions:
                                                                                                           •   Heating only
                                                                                                           •   Simultaneous heating and hot water to 55ºC.
                                                                                                           •   Hot water only
                                                                                                           •   Cooling only
                                                                                                           •   Simultaneous cooling and hot water with up to 100% heat recovery
                                                                                                           •   Simultaneous cooling and heating with up to 100% heat recovery

                                                                                                           • The range is very similar to the Prana BWR MTD in terms of features and
                                                                                                             control however the range allows these four pipe units to be applied on a
                                                                                                             wider range of applications.

                                                                                                           • The range includes single-circuit/two-compressor versions and also twin
                                                                                                             circuit/four compressor versions for larger output capacity. This
                                                                                                             configuration provides excellent load management capability which gives
                                                                                                             high performance and efficiency along with associated contingency
                                                                        ***modular capability                benefits and redundancy.

                                                                                                           • These fully optimised water source heat pumps provide partial or total
     Unit Summary                                                                                            heat recovery for the simultaneous production of chilled/hot water with
                                                                                                             hermetic rotary scroll compressors operating with R410A, plate heat
     PRANA BWR DHW UNITS: WW/WWR & BW/BWR                                                                    exchangers and thermostatically controlled expansion valve.
     CAPACITY: 40kW-360kW                                                                                  • Also these heat pump units will provide up to 100% duty on either primary
     POWER SUPPLY: Three Phase models                                                                        or secondary heat exchangers along with the ability to provide a
                                                                                                             combination of load capability heating and hot water simultaneously or
     These units provide simultaneous supplies of domestic hot water                                         heating and cooling simultaneously with up to 100% heat recovery. This
     and heating/air conditioning.                                                                           allows the heat pump units to provide this simultaneous output feature to
     HIGH EFFICIENCY & PERFORMANCE:                                                                          manage seasonal heating and cooling loads from the same heat pump unit.
     COP 4.1 (410% efficient)*                                                                             • Energy saving is achieved by the W3000 advanced control logic. The most
     *BWR DHW source flow temperature 0ºC/-3ºC & output flow temp 35ºC                                       efficient operational mode is set completely automatically and
                                                                                                             independently by the units controller, in order to minimize the absorbed
     COP 5.06 (506% efficient)*                                                                              energy whatever the cooling and/or heating demand might be.
     *WWR DHW source flow temperature 5ºC/10ºC & output flow temp 35ºC
     *Average COP for the Prana BWR & WWR MTD ranges
                                                                                                           W3000
     NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter
     system utilised. Care should be taken to ensure that the heat pump is installed in order to provide   The W3000 controller offers the latest control and operating
     efficient operational performance.                                                                    functions developed directly by Climaveneta utilising their
                                                                                                           experience gained within the field of heat pump design and related
     FEATURES & OPERATIONAL BENEFITS:                                                                      plant engineering. The keypad is generously sized with a full
                                                                                                           operating status display, the controls and detailed LCD make access
     • Full DHW and heating control                                                                        to machine settings easy and safe. Temperature regulation with a proportional logic capability
     • Simulataneous heating and cooling outputs                                                           is related to the return water temperature which provides the ability to satisfy simultaneously
     • Heating only or reversible heat pump                                                                heating, sanitary hot water and cooling requests with no need for mode changeover. The
                                                                                                           diagnostics include full management of alarms with black box function and an alarm recorder for
     • 100% heat recovery capability                                                                       analysis of unit performance. Monitoring is achieved through either Climaveneta devices or with
     • Suitable for a 4 pipe distribution system                                                           various options for interfacing to ModBus, Bacnet or Echelon & LonTalk protocols. The controller
                                                                                                           has the compatibility to operate with a remote keyboard (single controller management of up
     • 55ºC output temperature                                                                             to 10 modular units) along with a full time clock function for efficient programming of operation
     • Modular control for multiple unit configuration                                                     (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple
                                                                                                           operational- and ambient parameters are incorporated which allow the unit to reduce the number
     • Compact footprint for plant room positioning                                                        and duration of the defrost cycles with the benefit of increased overall energy efficiency.
37

                                      Prana BWR-DHW Ground Source & Geothermal Heat Pumps


       BWR-DHW                                                                              0152              0182             0202             0252             0262             0302             0412    0512         0612
       Cooling capacity                                             (1)       kW            48.6              55.8             65               73.8             83.2             97.5             127     159          206
       Total power input                                            (1)       kW            8.70              9.80             11.3             13.2             14.7             17.4             22.7    28.1         36.5
       EER                                                                                  5.59              5.69             5.75             5.59             5.66             5.60             5.59    5.64         5.63
       ESEER                                                                                *                 *                *                *                *                *                *       *            *
       Heating capacity                                             (2)       kW            52.1              59.7             69.3             79               88.9             104              135     169          219
       Total power input                                            (2)       kW            12.4              13.8             16.2             18.5             20.4             23.9             31      38.4         49.9
       COP                                                                                  4.20              4.33             4.28             4.28             4.36             4.37             4.35    4.40         4.38
       Cooling capacity                                             (3)       kW            40.4              46.7             54.1             61.7             67.9             82               106     133          172
       Total power input                                            (3)       kW            12.4              13.8             16.2             18.5             20.4             23.9             31      38.4         49.9
       Heat recovery capacity                                       (3)       kW            52.1              59.7             69.3             79               88.9             104              135     169          219
       No. Compressors/No. Circuits N.                                                      2/2               2/2              2/2              2/2              2/2              2/2              2/2     2/2          2/2
       Total power input kW
       Sound power                                                  (4)       dB(A)         73                74               74               74               75               76               77      78           79
       Sound pressure                                               (5)       dB(A)         42                43               43               43               44               45               46      47           48
       Length                                                       (6)       mm            1222              1222             1222             1222             1222             1222             1222    1222         1222
       Width                                                        (6)       mm            893               893              893              893              893              893              893     893          893
       Height                                                       (6)       mm            1496              1496             1496             1496             1496             1496             1496    1496         1496
       Operating weight                                             (6)       kg            450               470              490              505              525              550              745     825          910


       BWR-DHW                                                                              0604              0704             0804             0904             1004             1104             1204    1404         1604
       Cooling capacity                                             (1)       kW            194               225              255              285              317              365              413     468          522
       Total power input                                            (1)       kW            34.8              40               45.3             50.8             56.3             64.8             73      84.1         95.1
       EER                                                                                  5.58              5.63             5.62             5.61             5.63             5.63             5.66    5.56         5.49
       ESEER                                                                                *                 *                *                *                *                *                *       *            *
       Heating capacity                                             (2)       kW            208               240              270              303              338              388              440     498          557
       Total power input                                            (2)       kW            47.7              54.7             61.8             69.2             76.8             88.4             99.6    113          126
       COP                                                                                  4.36              4.38             4.37             4.38             4.40             4.39             4.41    4.41         4.42
       Cooling capacity                                             (3)       kW            163               188              212              238              266              305              346     392          438
       Total power input                                            (3)       kW            47.7              54.7             61.8             69.2             76.8             88.4             99.6    113          126
       Heat recovery capacity                                       (3)       kW            208               240              270              303              338              388              440     498          557
       No. Compressors/No. Circuits N.                                                      4/2               4/2              4/2              4/2              4/2              4/2              4/2     4/2          4/2
       Total power input kW
       Sound power                                                  (4)       dB(A)         86                87               88               89               90               91               91      91           91
       Sound pressure                                               (5)       dB(A)         54                55               56               57               58               59               59      59           59
       Length                                                       (6)       mm            2520              2520             2520             2520             2520             2520             2520    2520         2520
       Width                                                        (6)       mm            880               880              880              880              880              880              880     880          880
       Height                                                       (6)       mm            1810              1810             1810             1810             1810             1810             1810    1810         1810
       Operating weight                                             (6)       kg            975               1165             1365             1445             1610             1710             1810    1895         2000


                             MODULAR CAPABILITY
             MODULAR
                             The Prana BWR DHW range is designed for modular application to accommodate multi unit larger capacity requirements***.



                       r HFC     r HFC
                        R-410A    R-410A
            AXIAL        AXIAL




       Note:                                                                                                                                                                                               D
       1. Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C
       2. Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C
       3. Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C
       4. Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for
          Eurovent certified units; in compliance with ISO 3744 for non-certified units.
       5. Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-                                                                                                         L          W
          binding value obtained from the sound power level.
       6. Unit in standard configuration/execution, without optional accessories.




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without          Commercial Heat Pumps
prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment
details at point of quotation and/or order.
38
                                                                                                        Buffer Tanks
     Best practice standards require a buffer tank to be incorporated within any heat pump system. The buffer tank provides thermal
     mass and inertia to the system whilst providing a thermal buffer during the heat pumps defrost cycle.

     The buffer tank also provides an efficient means of incorporating any number of heat pumps or distribution circuits within a single system
     i.e. a standard multi tap buffer allows for 2 x heat pumps and 2 x output circuits to be easily connected.

     • Provide adequate thermal mass
     • Ensure system volume is maintained at all times (regardless of any zone control)
     • Provides thermal inertia during the defrost cycle

     The buffer tank also provides a thermal break between the heat pump and the distribution system, this allows both sides of the system
     (heat pump and property) to operate at the optimum temperature difference in order to achieve maximum efficiency. A heat pump will
     require a narrow temperature differnece (typically 5ºC to 6ºC) where as the distribution system may require a wider temperature difference
     i.e. when specifying a retrofit installation or similar.


     Buffer Tanks (Stainless)                                     90L     120L     210L     300L

     Capacity                                          litres     90      120      210      300
     Height                                            mm         732     920      1483     2020
     Diameter                                          mm         550     550      550      550
     Weight (empty)                                    kg         13      18       28       37
     Weight (full)                                     kg         103     138      238      337
     Standing losses                                   kWhr/24hr 0.80     1.00     1.60     1.93
     Maximum working pressure - cylinder bar                      3.5     3.5      3.5      3.5
     Maximum working pressure - space heating bar                 3.5     3.5      3.5      3.5
     Input connections heat pump x2                    mm         28      28       35       35
     Output connections heat pump x2                   mm         28      28       35       35
     Heat pump input connection tapping height         mm         464     652      1215     1752
     Heat pump output connection tapping height        mm         295     295      295      295
     Input connections heating x2                      mm         28      28       35       35
     Output connections heating x2                     mm         28      28       35       35
     Heating input connection tapping height           mm         295     295      295      295
     Heating output connection tapping height          mm         464     652      1215     1752
     Immersion Boss                                    inch       1.75    1.75     1.75     1.75
     Drain connection                                  inch       0.5     0.5      0.5      0.5
     Drain connection tapping height                   mm         220     220      220      220
     Fill connection                                   mm         22      22       22       22


     Buffer Tanks (Carbon Steel)                                  100 - 2000 litres capacity

     ICS HPT also provide a range of carbon steel buffer tanks up to 2000 litres in capacity. Please
     contact technical sales support for details.


     Buffer vessels are a high quality duplex stainless steel tank that contains a volume of water as
     per the specification table shown above.

     The Buffer store is insulated to a very high standard using high density HCFC free foam cased
     in a steel shell and therefore has an ozone deletion potential (ODP) of zero and a global
     warming potential (GWP) of 1.                                                                       Example: 210 Litre
39
                                                                                                                                                         DHW Cylinders
Stainless Heat Pump Optimised DHW is a range of unvented hot water storage cylinders, manufactured in the latest high quality duplex
stainless steel. They are designed to provide mains pressure hot water and are supplied as a package which complies with Section G3
of the Building Regulations. The appliance is extremely well insulated using high density HCFC free foam insulation with an ozone
depleting potential (ODP) of zero and a global warming potential (GWP) of 1. It is fitted with all necessary safety devices and supplied
with all the necessary control devices to make installation on site as easy as possible.

STAINLESS HEAT PUMP OPTIMISED (HP)
The Stainless Heat Pump Optimised DHW is an unvented hot water storage cylinder fitted with two high efficiency internal primary heat exchangers
especially designed for use with heat pump systems. These two heat exchangers can be connected in parallel to the heat pump circuit when a solar
thermal system is not installed. When both heat pump and solar thermal systems are installed, the top heat exchanger is connected to the heat pump
circuit and the bottom heat exchanger is connected to the solar circuit a shown below. All Stainless Heat Pump Optimised DHW models are fitted with
3kW (230Vac, 50Hz) immersion heater for raising the temperature of the stored water to about 60ºC after the heat pump heating cycle if necessary.


DHW Cylinders (Stainless)                                          HP180IND HP210IND                      HP250IND             HP300IND HP400IND

Capacity - total volume                             litres         180               210                  250                  300               400
Volume heated by IH                                 litres         113               135                  160                  195               270
Dedicated solar volume                              litres         65                75                   90                   105               130
Standing heat loss rate                             kWh/24h        1.40              1.60                 1.75                 1.93              3.33
Weight - empty                                      kg             33                38                   43                   49                61
Weight - full                                       kg             213               248                  293                  349               461
Pressure regulating valve setting                   bar            2.25              2.25                 2.25                 2.25              2.25
Expansion relief valve setting                      bar            4.5               4.5                  4.5                  4.5               4.5
Temperature setting (P&T valve)                     ºC             90                90                   90                   90                90
Pressure setting (P&T valve)                        bar            6.0               6.0                  6.0                  6.0               6.0
Expansion vessel size (volume)                      litres         18                24                   24                   35                2 x 24
Expansion vessel initial charge pressure            bar            2.25              2.25                 2.25                 2.25              2.25
Height A                                            mm             1295              1483                 1733                 2020              2040
Diameter B                                          mm             550               550                  550                  550               630
22mm secondary return C                             mm             -                 1127                 1377                 1577              1592
22mm compression cold feed D                        mm             442               442                  522                  522               557
P & T valve E                                       mm             1053              1241                 1491                 1777              1784
22mm solar return - bottom coil F                   mm             223               223                  223                  223               238
22mm solar fl ow - bottom coil G                    mm             352               352                  472                  472               548
28mm primary return - top coil H                    mm             467               542                  647                  742               641
28mm primary fl ow - top coil I                     mm             1072              1232                 1467                 1562              1791
Dual CT & OHT pocket - 1 top J                      mm             732               837                  962                  1092              1076
Dual CT & OHT pocket - 2 bottom K                   mm             419               419                  539                  539               651
Solar sensor pocket - 1 top L                       mm             882               1000                 1180                 1367              1382
Solar sensor pocket - 2 bottom M                    mm             203               203                  262                  262               334
3kW immersion heater height N                       mm             457               522                  607                  702               640
Surface area of solar heater coil                   m2             0.68              0.68                 0.97                 0.97              1.27
Solar coil thermal rating @ 25 l/s                  kW              -                -                    -                    -                 -
Solar coil pressure loss @ 25 l/s                   bar            0.191             0.191                0.241                0.241             0.31
Internal heat exchanger surface area                m2             1.36              1.56                 1.94                 1.94              2.72
Internal heat exchanger thermal                     kW             19.0              20.5                 21.5                 25.0
rating @ 25 l/s
Internal heat exchanger pressure                    bar            0.356             0.382                0.457                0.457
loss series @ 25 l/s

Sanitary hot water cylinders/stores                                                             1000 - 5000 litres capacity

ICS HPT also provide a range of sanitary hot water cylinders/stores for commercial use up to 5000
litres in capacity. Please contact technical sales support for details.
                                                                                                                                                                              NOTES
                                                                                                                                                                              1. Not all models - see table 1
IMPORTANT NOTES:                                                                                                                                                              2. Recovery times based on Primary Coil/L.H Duty
1. All Stainless Lite HP models are suitable for both open vented and sealed                                                                                                     (i.e. assumes the boiler output is adequate)
   primary systems.
                                                                                                                                                                              3. All connections are supplied with compression
2. Stainless Lite HP models must not be used with solid fuel boilers or steam as the heat source.
                                                                                                                                                                                 fittings for direct connection to copper pipework
3. Heat pumps will heat the domestic hot water to between 45ºC - 55ºC, therefore provision should be
   made to periodically heat the cylinder to about 65ºC to prevent growth of legionella.


ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided within
the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.
40
                                                                   Fan Coils - Hydronic
     ICS Heat Pump Technology provide a complete range of DeLonghi-Climaveneta Fan Coils and internal Air Handling Units to
     complement the Heat Pump range.

     This high quality range of Fan Coils and Air Handling Units allows a complete climate control system to be specified which can provide
     heating, air-conditioning and domestic hot water.

     The benefits of these water based cooling and heating systems can be significant, for example the amount of refrigerant within the
     system is reduced and the potential risk of refrigerant leaks is minimised when compared to refrigerant based direct expansion systems.

     Also system installation is simplified as no high pressure refrigerant pipework is required within the building as the refrigeration system
     is positioned externally within the fully packaged Air Source Heat Pump or within the Ground Source Heat Pump positioned within the
     plant area.

     These fan coils are ideal for use with either heating only or reversible heat pumps providing a very efficient and environmentally conscious
     heating and/or air-conditioning system. The Climaveneta hydronic fan coil ranges encompass each key fan coil area of application:


     1.   High wall units
     2.   Ceiling mounted cassettes (2 or 4 pipe)
     3.   Floor/low wall mounted cased units (2 or 4 pipe)
     4.   Ducted systems for residential or commercial specification (2 or 4 pipe)

     In addition to the more traditional commercial applications, fan coils are gaining popularity within the         Residential Heat Pumps
     commercial & residential retrofit markets as they are proving an ideal way to provide an increased kW
     capacity to existing radiator size restricted applications i.e. a significantly greater kW capacity from a
     compact controllable unit.
                                                                                                                      Commercial Heat Pumps




     MHD. HIGH WALL MOUNTED FAN COILS
     Hi-wall type terminal 2.15 - 4.70kW

     MHD fan coil terminals are the premium high-wall hydronic fan-coil from
     Climaveneta. The compact design and quality finish of this model coupled with
     the exclusive elegance soften the visual impact and make the units ideal for
     both office residential installations. These units provide all the standard befits
     of a high wall fan coil but with the added benefit of a water based system, so
     reducing refrigerant within the building in line with the F-Gas regulations.




     CHD. CEILING MOUNTED CASSETTE
     Cassette type terminal 2.7-9.3kW

     The CHD hydronic fan-coil cassette from Climaveneta is an electro-mechanical unit,
     available in two versions: For two pipe installation (unit with single coil) and for
     four pipe installation (unit with double coil). A wide range of sizes and easy
     installation make them suitable for various types of application. CHD units are
     registered within the EUROVENT certification programme. These units provide all
     the standard befits of a ceiling mounted cassette but with the added benefit of a
     water based system, so reducing refrigerant within the building in line with the
     F-Gas regulations.

     •    U-2T electromechanical version for 2-pipe system
     •    U-4T electromechanical version for 4-pipe system
41

                                                                                             Wall, Ceiling, Floor Mount & Ducted Fan Coils



                    I-LIFE. LOW WALL/FLOOR MOUNTED FAN COILS
                    High efficiency fan-coil with synchronous motor electronic
                    switches, with cabinet or built-in version 1.91 - 7.47kW

                    i-LIFE fan-coils incorporate modulating speed low energy centrifugal fans. This new
                    generation of fan-coil guarantees air flow regulation from 0% to 100% and energy
                    consumption is reduced by more than 50% when compared to a traditional unit.
                    In addition new commands & controls are available which manage all the functions
                    offered by this range of high specification terminal units. Retrofit capability allows
                    the i-life fan coil to provide an alternative to traditional radiators, offering
                    significantly greater capacity in an extremely compact unit.

                    •      DFI built-in version, front air intake
                                                                                                                                                                  IDEAL
                                                                                                                                                                RADIATOR
                    •      DFU version with cabinet, front air intake
                                                                                                                                                              REPLACEMENT
                    •      DLI built-in version, bottom air intake
                    •      DLU version with cabinet, bottom air intake


                    TYPICAL UNIT CONTROLLER – IK UNIT SHOWN
                    (contact technical support for specific controller configuration)

                    •      Configurable control with LCD screen
                    •      On-Off - modulating valve-unit
                    •      Master/Slave multiple configuration network
                    •      Quick installation with two wire connection




                    HWD. COMMERCIAL DUCTED/FREE BLOWING FAN COIL
                    High head ducted type terminal 16.8 - 29.8kW

                    The HWD HP belongs to the ducted fan-coil high head range from Climaveneta.
                    The units allow for vertical or horizontal installation with variable airflow
                    adjustment, the modular configuration allows for ease of installation enabling
                    the unit to adapt to a variety of applications. The unit can be mounted
                    horizontally or vertically with a variable modular configuration to match the
                    demands of a particular specification. High pressure fan capability allows the
                    HWD range of terminals to provide the ideal internal air handling unit selection
                    to operate with a medium or High temperature heat pump.

                    •      Base version
                    •      Single or twin coil version
                    •      Heating or cooling option
                    •      Flexible plenum configuration




                    HWD. COMMERCIAL WALL/FLOOR MOUNT FAN COILS
                    High Head free blowing wall or floor mount terminal 16.8 - 29.8kW

                    As with the HWD HP ducted unit shown above, these wall or floor mounted versions
                    will provide heating or cooling with the option of flexible installation and positioning.
                    The units can be provided with either inlet and/or outlet plenum boxes which will
                    allow specification either for new build or retrofit/refurbishment applications.
                    •      Base version
                    •      Single or twin coil version
                    •      Heating or cooling option
                    •      Inlet and outlet plenum boxes available




ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided within
the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.
42
                          Application & Specification Support
            Technical and application support is a critical element of the ICS-DeLonghi operation and is an area which is given the highest priority. The dedicated
            team of heat pump specialists provides both telephone and field base support as required. The majority of questions asked by ICS customers and
            partners can be dealt with via our technical support desk which is manned by experienced engineers who have hands on knowledge of both the
            equipment and applications. You can be sure that your enquiry or query will be dealt with as a priority until the correct solutions is highlighted and
            the situation is dealt with appropriately whether this be a new commercial specification or a technical/application question.

            ICS provide the award wining partner hub to all APP registered users. The partner hub provides a complete access point for all application,
            specification, equipment and associated information on a 24/7 basis. The hub will provide you with many standard technical and sales documents
            but importantly also providing you with application and specification tools to assist you in producing quotations and/or specifications within the
            residential and commercial markets. contact us for your unique password and log in details (activated when your APP card is registered).



            HEAT PUMP SPECIFICATION AND INSTALLATION MADE EASY,WITH 24/7
            ON-LINE, SUPPORT AND AN EXTENSIVE IN-HOUSE AND NATIONAL
            APPLICATION AND TECHNICAL SUPPORT STRUCTURE.
            • Internal application support engineers - specification advice, technical application support and equipment selection
            • Field based specification engineers - site survey/application support, client technical meetings and CPD service
            • Online specifier hub - 24/7 information availability, secure login, specifier information and technical details


            THE COMPLETE SPECIFIER/INSTALLER SUPPORT SERVICE

            ACCESSORIES
            ICS Heat Pump Technology provide a range of accessories in order to simplify and enhance the heat pump package. This
            ancillary equipment is usually difficult for the installer/contractor to source on a local basis and hence there is a reason
            to source as a package with the heat pump to minimise installation time.



            ENCLOSURES                                                                                                                                                   INSTALL PACKS
            Heat pumps can call for specific application demands in                                                                                                      A heat pump installation can be simplified with the
            terms of either noise or aesthetic requirements. These                                                                                                       addition of an Install Pack which is provided to
            are the applications where ICS Heat Pump Technology                                                                                                          reduce the potential difficulty in sourcing specific
            can provide a range of enclosures to match the on-site                                                                                                       items locally. The ICS Install Packs include all the
            requirements relating to the majority of residential and                                                                                                     items that an on-site installation team may find
            commercial heat pump applications. These enclosure                                                                                                           difficulty in sourcing on a timely local basis.
            systems range from a standard security enclosure to a                                                                                                        Importantly these Install Packs do not include any
            specific colour coordinated designed system or a low                                                                                                         fittings or pipe work relating to the installation but
            noise heat pump acoustic enclosure with a specified                                                                                                          are designed to provide the more specific heat
            output rating.                                                                                                                                               pump related items:




            ADDITIONAL ANCILLARY EQUIPMENT
            In addition to the above ICS HPT are also able to provide a range of ancillary equipment to compliment the heat pump installation/specification. This
            equipment includes the EcoAmp variable Inline Electric Heater which provides an ideal supplementary boost option for low ambient support or to
            supplement a single phase heat pump installation.
            Please contact technical sales support for details of the EcoAmp heater and the full range of ancillary equipment available




 ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided within
 the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.
43
                              Technical & Service Support

COMPLETE TECHNICAL AND SERVICE SUPPORT WITH A SPECIALIST TEAM
PROVIDING PRE INSTALLATION, COMMISSIONING AND AFTER SALES SUPPORT TO
MATCH THE REQUIREMENTS OF EACH PARTICULAR PROJECT



                                                                •   5 UK service centres nationwide
                                                                •   Specialist heat pump service team
                                                                •   Commissioning service
                                                                •   Technical/Installation support
                                         Glasgow*               •   Technical help desk service
                                                                •   Direct manufacturer support




               Dublin               Blackpool
                                                           Bradford



                                             Birmingham


                                                            Southampton
        * Regional Distributor,
          Thermsaver




 24/7 Access to invaluable product and technical         Direct access to the on-line Partner Marketing
  information                                              tools and support team
 Heat Pump selection and sizing tools                    Latest Heat Pump News; company, product and
 Direct contact to our in house dedicated                 industry; LCBP, RHI
  technical and sales help desk                           Latest product and technical document updates
 25+ field based service team                            Partner Hub password protected user access




                                                    Commercial Heat Pumps                  Residential Heat Pumps
www.icsheatpumps.co.uk
             3 Trident Business Park, Amy Johnson Way, Blackpool, FY4 2RP

T: 01253 685100 F: 01253 685101 e: enquiries@icsheatpumps.co.uk




                                                                            2011 Product Guide v1