SlideShare a Scribd company logo
PRODUCT CATALOG
SAMSUNG VRF SYSTEM
HIGH EFFICIENCY SYSTEM AIR CONDITIONER
Carlisle
6 Pine Hill Drive
Carlisle, PA 17013
866-243-6498
Fort Worth
3001 Northern Cross Blvd. #361
Fort Worth, TX 76137
817-838-6066
Los Angeles
8750 Pioneer Blvd.
Santa Fe Springs, CA 90670
888-699-6067
New Jersey
411 Hackensack Av.
Hackensack NJ 07601
www.samsungdvm-s.comVersion 1-4.13
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
3
- Chief Marketing Officer, SAMSUNG
“Put simply, our differentiation is centered
on producing innovative technology that brings
genuine change to people’s lives. We do this
by bringing a relentless focus on consumer
experience and product innovation in everything
we do.”
Best Global Brand Rankings ($Value rounded off to nearest billion)
$18Billion
$18Billion
Rank-21st
2008 2009
Rank-19th
2010
Rank-19th
$19Billion
Rank-17th
2011
$23Billion
Rank-9th
2012
$32Billion
ECO-FRIENDLY SAMSUNG
Preserving for future generations
Thinking of people and the environment, Samsung has
been developing products/solutions that are eco-friendly
without sacrificing performance. Realizing the hopes for
a greener, healthier life for people and the generations
that follow, Samsung’s environment-friendly technologies
work to make the world a safer and more liveable place.
Eco-Friendy Air Conditioners by Samsung
Making continuous efforts to stay eco-friendly, Samsung
air conditioners use R-410A, an environment-friendly
refrigerant to help rid the air of pollutants and restrain the
use of materials with high global warming potential (GWP).
These energy-efficient air conditioners not only save you
money, but help conserve the environment.
2
MOVING FORWARD WITH OUR CUSTOMERS
SAMSUNG’S DVM SYSTEMS ARE A GLOBAL OPERATION
Various groups from all over the world choose Samsung’s DVM systems for their proven performance.
Project
Location
Project
LOCATION: U.A.E
PROJECT: RESIDENTIAL BUILDING
LOCATION: CHINA - PROJECT: INTERNATIONAL AIRPORT
LOCATION: VIETNAM
PROJECT: HOTEL
LOCATION: B.C., CANADA
PROJECT: DOUGLAS COLLEGE
LOCATION: TURKEY
PROJECT: PRINCESS RESORT
LOCATION: KOREA
PROJECT: SOCCER STADIUM
LOCATION: TEXAS, USA
PROJECT: HMS
LOCATION: HUNGARY - PROJECT: SHOPPING CENTER (see details above) LOCATION: TENNESSEE, USA - PROJECT: LIPSCOMB COLLEGE
Hungary’s most beautiful shopping center, the Váci 1 was recently
outfitted with Samsung’s DVM system. This was a very ambitious
project, not only because the building is over 129,000 sq.ft., but
also because it has been a UNESCO WORLD HERITAGE site since
1933. Due to this, extreme care and dedication went into
preserving the building’s infrastructure and interior designs. When
needed, Samsung engineers were able to delicately install and
hide indoor units behind sofas and walls, to avoid disrupting the
original interior architecture. 13 systems were able to act as 1, with
features such as DMS, giving engineers total access and the ability
to monitor and adjust the system over the internet or ethernet. All
in all, the project was ahuge success for all parties involved.
PROJECT DETAILS*
Location: Váci 1 Shopping Center in Budapest, Hungary
Equipment: 60 indoor units in common areas
252 indoor units installed in 72 shops
52 outdoor units
13 total systems acting as 1
Building: 130,000 sq. ft.
7 total floors (2 underground, 5 above ground)
100 yrs old
Marble walls and floors
UNESCO WORLD HERITAGE site
*You can view the complete video of this project in the media
section at www.samsungdvm-s.com
LOCATION: QATAR
PROJECT: OFFICE BUILDING
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
54
Location
Project
Location_Croatia
Project_
Project_
Location_
Project_
CAPACITY TABLES
noT21noT01noT8noT6eziS
6 Ton
1noT8
1
1
1
1
1
1
1
1
10 Ton 1
12 Ton 1
noT41
noT61
18 Ton
20 Ton 2
22 Ton 11
24 Ton 2
111noT62
111noT82
30 Ton 2
32 Ton 12
34 Ton 21
36 Ton 3
SingleC/UDoubleC/UTripleC/U
AM144FXVAJR/AA
AM144FXVAFR/AA
AM144FXVAJH/AA
AM144FXVAJR/AA
AM120FXVAFH/AA
AM120FXVAFR/AA
AM120FXVAJH/AA
AM120FXVAJR/AA
AM096FXVAFH/AA
AM096FXVAFR/AA
AM096FXVAJH/AA
AM096FXVAJR/AA
AM072FXVAFH/AA
AM072FXVAFR/AA
AM072FXVAJH/AA
AM072FXVAJR/AA
AM053FXMDCH/AAAM048FXMDCH/AAAM036FXMDCH/AA
12 Ton10 Ton6 Ton5 Ton4 Ton3 Ton
HP (208/230V-1Ph)
HP (208/230V-3Ph)
HR (208/230V-3Ph)
HP (460V-3Ph)
HR (460V-3Ph)
HP - Heat Pump / HR - Heat Recovery
OUTDOOR UNITS
3-5
Ton
6
Ton
8-12
Ton
4 Way
Cassette
Mini 4 Way
Cassette
1 Way
Cassette
H.S.P. Duct
M.S.P. Duct
Slim Duct
Wall Mount
Ceiling/Floor
Mount
7,500 BTU 9,500 BTU 12,000 BTU
INDOOR UNITS
18,000 BTU 20,000 BTU 24,000 BTU 30,000 BTU 36,000 BTU 48,000 BTU 76,000 BTU 96,000 BTU
8 Ton
TABLE OF CONTENTS
P6 - P21
OUTDOOR UNITS
P22 - P47
INDOOR UNITS
P66
DVM PRO
P68 - P97
SPECIFICATIONS
P48 - P65
INDOOR UNITS
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
76
OUTDOORUNITS
OUTDOORUNITS
INNOVATIVE TECHNOLOGY
Samsung’s new 3rd generation technology adopts dual inverter compressors and an upgraded vapor injection system which
surpasses the performance of previous versions of the system. This optimizes energy efficiency, providing energy savings.
• 3rd Generation Technology
The innovative Dual Smart Inverter feature has both compressors operate simultaneously,
providing balanced oil distribution, quick cooling & heating and better energy efficiency.
Upgraded vapor injection system within the compressor increases the refrigerant
flow rate by 20% compared to conventional products.
• 3rd Generation Vapor Injection System
• Dual Smart Inverter
1st generation
(Variable + Fixed Units)
2nd generation
(Variable + Fixed Compressors)
3rd generation
(Variable + Variable Compressors)
+
Inverter AInverter A Inverter B
Dual Smart Inverter
Refrigerant Vapor Injection
DVM S is a highly innovative system that adopts the new 3rd generation SSC
(Samsung Scroll Compressor) technology. With its Dual Smart Inverter, DVM S
provides the world, top class energy efficiency and the most powerful cooling
and heating performance.This is the perfect air conditioning system that
satisfies all types of environments, including large buildings.
• Innovative Technology
• High Efficiency
• Smart Management
• Flexible Installation
• Comfortable & Reliable Operation
• Heat Recovery
As High as IEER 27 / SCHE 30
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
98
OUTDOORUNITS
OUTDOORUNITS
• Dual Smart Inverter System
This 3rd generation feature adopts a dual inverter compressor that upgrades refrigerant flow and the motor’s operating
performance. The Dual Smart Inverter System achieves unsurpassed energy efficiency.
DSI (Dual Smart Inverter) System
• Dual Smart Inverter : SSC + SSC
• 3rd Generation Vapor Injection
• Wider operation range of BLDC motor (20-140Hz)
Low-pressure refrigerant
suction
High-pressure refrigerant
discharge
With compressor speed acceleration and simultaneous starting, DVM S provides quick cooling and heating performance.
• Quick Cooling & Heating
Conventional
DVM S
DVM S
CONVENTIONAL
CONVENTIONAL
33% higher heating
Fast Heating PerformanceFast Frequency AccelerationQuick Start (Simultaneous Operation)
DVM S
9 min
10 min
7 min 0
20
40
60
80
100
Hz
0
20
40
60
80
100
Hz
ON
90 sec5 sec
ON
Air Cooling Method
Low
Efficiency
ConventionalDVM S
Refrigerant Cooling MethodThe PCB is cooled by the refrigerant, ensuring better stability.
• Refrigerant PCB Cooling System
ConventionalDVM S
start
INVINVINVINVINV
after extended operationstart after extended operation
FIXED FIXEDINV
Conventional
(Inverter + Fixed)
(Inverter + Inverter)
Case 3Case 2Case 1
OFFON ON ON ON
ON ON ON ON
OFF
OFF OFF
INV
FIXED
Thanks to capacity control, the DSI (Dual Smart Inverter) system responds to subtle indoor load changes, saving energy.
In a conventional system composed of inverter and fixed compressors, one compressor operates longer than the other which
results in one compressor wearing down faster. This in fact decreases compressor durability and life span. However, with
the DVM S Dual Smart Inverter System, each compressor operates in unison with the other so the overall durability and life
span of the compressors increases.
• Enhanced Compressor Durability
With large oil storage and low OCR, DVM S can ensure reliability even in high altitude applications that require long piping.
• Large Oil Storage Capacity
DVM SCompany CCompany BCompany A
Operation level
Initial level
44oz
30oz27oz
17oz
Oil storage amount
70% reduced
5.71
5.58
1.8
1.43
0.82
3.95
60 80 100 RPS
OCR%
OCR (Oil Circulation Ratio) amount
DVM S ensures stable and equal oil balancing without requiring an extra oil balancing pipe.
• Auto Oil Balancing
ConventionalDVM S
BalanceBalance
• Fixed + Inverter Compressor
• Oil unbalanced (Balance Pipe is necessary)
• Inverter + Inverter Compressor
• No oil balance pipe
INV INV INV INV INV
INV FIXEDINV FIXEDINV
3 r d G e n e r a t i o n V a p o r I n j e c t i o n
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
1110
HIGH EFFICIENCY
DVM S has achieved top class energy efficiency by adopting a dual inverter compressor with vapor injection system.
Simultaneous heating/cooling efficiency: as high as 27 IEER, 30 SCHE.
• Top Class Energy Efficiency
OUTDOORUNITS
OUTDOORUNITS
35
30
25
20
15
10
5
0
6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
Samsung
Company D
27.9
27.1
26.06 25.88
24.75 25.52
26.64
24.39 24.08 23.97 23.26
24.45
23.74 23.04
18
15.4 15.3 16 16.2 15.5 15 14.8
15.9 15.8 15.4 14.9
SCHE comparison
30 29.6
28
26
24
22
20
18
16
14
12
10
6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36
IEER comparison
Samsung
Company D
23
27
24.2
22.7
21.9
20.7
19.6
20.2
19.2
18.1 18.6
17.7
16.9 17.1
16.3
15.5
21.5
18.8
17.2 17.6
20.2
19.1
19
16.1
19.1
18.8
17
16.1
15.3
SCHEIEER
• Plate Heat Exchanger
The Plate Heat Exchanger type intercooler that Samsung’s DVM S adopts improves cooling and heating efficiency. Heat
efficiency with PHE has been improved by about 30% compared to conventional products with the Shell & Tube type
intercooler and by 50% compared to competitors’ products with the Double Tube type intercooler.
EER
Heat Exchanger Performance
150%
115%
100%
Double Tube
Shell & Tube
PHE Intercooler
• Adaptive Sine Wave Control
Adaptive Sine Wave Control can reduce THP (Total Harmonic Distortion).
[Hz]
[A]
[Hz]
[A]
Conventional square wave controller New Sine Wave Controller
• Assymetric Scroll Design
With an improved fluid dynamic design, DVM S minimizes compression loss during the compression of .
DVM S Conventional
1
2 Loss
2 1
* Suction from two different sides and discharge through one can cause
collision of refrigerant gas which results in friction loss in the compressor.
* No friction loss in the compressor, thanks to sequential suction
and discharge .
Loss
1
Suc.
Discharge
1 2
Suc. Suc.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
1312
SMART MANAGEMENT
DVM S has a smart management system that facilitates self-diagnosis, auto commissioning, auto management and mobile data
transmission. Management is easy and convenient with the ability to control the system with your smart phone or tablet PC.
• Auto Commissioning & Management
OUTDOORUNITS
OUTDOORUNITS
• WiFi Monitoring System
With S-Checker, DVM S can be monitored by computers and handheld devices.
With S-Checker, the commissioning time for DVM S has shortened
considerably from days to a mere 50 minutes, and the test results
are automatically stored and reported wirelessly.
• Reduced Commissioning Time
WiFi connection
Check multiple outdoor
equipment simultaneously
Smart Phone
Tablet PC
DVM S
Serial Port F1/F2 communication lines
Conventional
• Self-Diagnosis Mode
DVM S monitors the operation status and displays an error code in response
to any sign of abnormal operation, making it easier to solve any problems with
the system.
• Automatic Data Backup
If a malfunction occurs with the DVM S outdoor unit, the last 30
minutes of operation data are stored for stored with automatic data backup.
S-NET Pro
• Easy Access
With the small opening on the front side of the outdoor unit,
checking the status of it and setting options is simple.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
1514
FLEXIBLE INSTALLATION
• Longest Piping Length & Highest Elevation
OUTDOORUNITS
OUTDOORUNITS
The knock-out holes for piping, power and communication cables are located in a variety of different areas of the
condensing unit, allowing for simpler installation of DVM S where the piping and cable direction can be selected
from the front, left and right side.
• Versatile Piping Connection with Various Knock-Out Holes
Height between
indoor and
outdoor units
360ft
Height between
indoor units
(*for heat pump system)
164ft*
The longest
piping length
721ft
Side : Communication
cable outlet
Non-polar communication between indoor and outdoor units makes wiring work much easier. This is also safer since the
outdoor unit will protect itself if the communication cable is connected to a power teminal by mistake.
• Easy and Safe Wiring
Normal operation is possible even when communication
cables are not connected properly
ProtectedNon-polarity
Indoor Unit A Indoor Unit B
Indoor Unit A Indoor Unit B
Power Breaker
Outdoor Unit
Air conditioner is protected even when power /
communication cables are not connected properly
DVM S DVM S
Since the piping distance is far between the outdoor units and indoor
units, the individual indoor units perform capacity connection control
and automatic refrigerant balancing to secure balanced performance
between the units.
• Optimized Refrigerant Distribution Control
Auto pressure
correction
P (Pipe pressure loss)
DVM S provides the refrigerant pump-down/out functions to facilitate easy and convenient replacement of the product, as well as
additional installations and maintenance. When the outdoor unit needs maintenance, it is possible for the refrigerant to recover into
indoor units and pipes. It is also possible to recover refrigerant into outdoor units when moving indoor units or performing
maintenance of pipes.
• Refrigerant Pump-Down & Pump-Out
Refrigerant Pump-out Function
Refrigerant Pump-out Function
To properly deal with unexpected and varying installation conditions, DVM S
is designed to manage high external static pressures up to .32” H2O.
• High External Static Pressure
.32”H2O
DVM S allows an extended piping length of up to 721ft and units will still perfom great over wide areas. With this technology,
installation is available with a maximum height level of 360ft, which is equivalent to 20 stories (where each story is considered
to be 16.4ft in height).
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
1716
COMFORTABLE & RELIABLE OPERATION
Without changing the outdoor unit’s settings, each duct has an indoor discharge temperature control function. This offers greater
comfort in either cooling or heating mode (cooling operation: ~61°F / heating operation: ~ 97°F).
• Indoor Discharge Temperature Control
OUTDOORUNITS
OUTDOORUNITS
DVM S has applied an operation control system to the outdoor fans that drastically reduces noise level. The Quiet Operation
feature lasts 12 hours, allowing you to rest in peace during the night.
• Quiet Operation for Night Time
DVM S can control peak current and power consumption.
This is especially useful when the supply of electricity is
insufficient or when you want to block excessive energy use.
• Peak Power-Demand Control
When you use DVM S, there’s no need to worry about using an
additional unit for severe temperatures. It has a wider temperature
allowance, meaning you can cool in the burning heat of 118°F or
provide heat in the freezing cold of -4°F.
• Wide Operating Temperatures
Snow that accumulates and covers the outdoor units during
the winter must be removed in order for the units to operate
properly. The Snow Prevention function removes accumulated
snow, so you don’t have to do it yourself. Outdoor units will
blow away covered snow every 30 minutes.
• Auto Snow Blowing Function
The hydrophilic coating facilitates efficient heat exchange and delays the onset of frost formation to provide consistent heating
performance. An anti-corrosive coating also helps our units resist corrosion from the elements.
• Corrosion and Frost Resistance
Too Hot
Too Cold
Pressure Down
Pressure Up
Supply of Comfortable Air
Supply of Comfortable Air
Less than 50dB noise
Peak Operation
Temperature Change
Operation Mode
AfterBefore
Less Energy
Consumption
Reduced amount
of electric current
Maximum amount of electric current
Before & after peak power-demand control
Temp° F 14
50
32
68
86
104
122
SAMSUNG
23°F-118°F
SAMSUNG
4°F-75°F
Heating
Cooling
Before After
Corrosion resistant finishing on heat exchanger fin
Hydrophilic layer acrylic
resin+surfactant
Anti-corrosive
layer epoxy acrylic
Raw aluminum
material
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
1918
HEAT RECOVERY
Single outdoor units can operate all the indoor units in both cooling and heating mode. They can also simultaneously operate in
cooling and heating mode.
• Simultaneous Cooling & Heating
OUTDOORUNITS
OUTDOORUNITS
DVM S can continuously operate in heating mode with rotational defrost operation. Stay warm and comfortable as the
heating mode continues for a longer period of time.
• Non-Stop Heating Operation (during defrost & oil return cycle)
DVM S HR uses an MCU kit that is less than 32% the size of
its competitor. The MCU has an internal On/Off valve that enables
control through the EEV valve control, and the sub-cooler also
supports fine-tuned control. Enjoy a temperature-controlled
environment through improved performance and reduced noise.
• Mode Change Unit (MCU) Kit
Hotel
Cooling
MCU Kit
Office
Hospital
Heating
Cooling operation for indoor
environments where cooling load
occurs all year round due to devices
and lighting that generate heat.
Heating operation for indoor
environments where heating
load occurs due to the outdoor
environment.
Recommended Sites
MCU Kit
196lbs
57lbs
SAMSUNG
Company A
60”
8”
7.7”
24”
28.6”18.5”
SAMSUNG
CompanyA
32%
Smaller
71%
Lighter
Weight ComparisonVolume Comparison
Heating
STEP 0: Normal Heating Operation
STEP 1:Non-stop Heating Operation STEP 2: Non-stop Heating Operation
STEP 3: Non-stop Heating Operation
)2petstsorfedlanoitatoR()1petstsorfedlanoitatoR(
(Rotational defrost step 3)
Heating Heating
DefrostingHeating Heating HeatingDefrosting Heating
HeatingHeating Defrosting
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
2120
OUTDOORUNITS
OUTDOORUNITS
Mini DVM ECO
The footprint of the Mini DVM Eco outdoor unit has been decreased by 11% and the volume has been decreased by 5%.
• Small Footprint and Volume
5dB
53/55
4HP 5HP 6HP
58/60
Conventional
4dB
51/53
55/57
Conventional
5dB
50/52
55/56
Conventional
The single phase Mini DVM Eco outdoor unit can support up to 9 indoor
units, and is an ideal solution for residential and semi-commercial spaces.
Eco
• Top-Class Energy Efficiency
• Small Footprint and Volume
• Flexible Piping Design
• Low Noise Level
COP
3.62
4.32
3.46
4.12
3.85
* Due to ongoing product development, specifications can change without prior notice.
Conventional
Conventional
3.39
Conventional
Top-Class Energy Efficiency
4HP 5HP 6HP
A Variety of Indoor Units
5%
reduction
Conventional
11%
reduction
Eco
Volume Comparison Footprint Comparison
Mini DVM Eco’s piping length goes up to 492ft, and a maximum
level difference of 164ft. With such long distances, a variety of
different system designs can be achieved.
• Flexible Piping Design
Level difference
between Indoor
and Outdoor
Units
164ft
492ft
The longest
piping length
Mini DVM Eco is quieter compared to our conventional
models.
• Low Noise Level
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
2322
INDOOR UNITS
Samsung’s cassette type indoor
units give the finishing touch to
your interior design. We also
use the most advanced
technologies to offer optimized
comfort and pleasure.
CASSETTE TYPE
Duct type indoor units visually
blend well into ceilings,
enhancing the beauty of your
interior space with their
compact and slim size
while giving you flexible
installation options.
HIGH STATIC PRESSURE (HSP)
DUCT
MEDIUM STATIC PRESSURE
(MSP) DUCT
SLIM DUCT
DUCT TYPE
With their stylish and sophisti-
cated designs, Samsung wall
mounted type air conditioners
offer cool, clean, and healthy
freshness enhancing your
everyday life.
NEO FORTE
WALL MOUNTED
Samsung’s ceiling/floor type
installs on the ceiling
(non-recessed) and low-wall
installation near the floor for a
more efficient and convenient
installation. No modification is
needed with this multi-position
unit.
CEILING / FLOOR MOUNT
CEILING/FLOOR MOUNT
4 WAY CASSETTE
Wide blades in the indoor unit deliver cool or warm
air at greater distances to provide even cooling and
heating throughout the room.
• Powerful Airflow
With its newly improved design, the 4 Way Cassette brings sophistication and provides clean air while adding a sense of class to your
interior. Not only is this unit attractively designed, it also uses advanced technologies to optimize your comfort in any environment.
Feel the power and enjoy the beauty with the new 4 Way Cassette.
Available Capacities:
9,500 / 18,000 / 24,000 / 30,000 / 36,000 / 48,000 BTU
PRODUCT FEATURES
1-Way Cassette
New Blade Conventional
4-Way Cassette
The newly designed panel will control air direction
in a way to avoid contact with the ceiling. This new
design will prevent dust from accumulating on the
ceiling after long periods of operation, keeping
your interior space cleaner than ever.
• Ceiling Dust Prevention
New BladeConventional Blade
Ceiling Ceiling
INDOORUNITS
INDOORUNITS
MINI 4 WAY CEILING CASSETTE
4 WAY CEILING CASSETTE
1 WAY CEILING CASSETTE
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
2524
4 WAY CASSETTE FEATURES CONTINUED . . .
The lift-up drain pump lifts condensed water up to 29.5”
compared to our competitor’s limit of 27.5”, making
installation more flexible and convenient.
• High-Lift Up Drain Pump
Fresh air can enter through the cassette unit so you
can enjoy even fresher air in your room.
• Fresh Air Intake
Max:29.5”
Ceiling
Company A
Lift-up Range
29.5”
27.5”
SAMSUNG
Fresh Air
Sub Duct enables you to use the same air conditioner unit
to cool an additional smaller space nearby. (A cassette unit
is fitted with a knockout component to accommodate this).
• Sub Duct
The simple display design with its rounded corners adds a
neat and tidy feeling to your interior.
• Simple Display Power
Time
Defrost
Clean
Power
Defrost
Time
Clean
The 4 Way Cassette uses a new, neat and clean design. The completely
hermetic blade structure keeps the indoor unit clean preventing dust or
other foreign substances from entering the unit. The internal parts of the
indoor unit are also out of sight when the blade is shut, improving the
unit’s appearance.
• Neat and Clean Design
Samsung’s 4 Way Cassette indoor unit is now lighter in weightat 37.5lbs. It is
the lightest of its type in the industry, about 35% lighter than our competitor’s
4-way cassette.
• Light Yet Robust Design
Based on 10kW
40%
64lbs37.5lbs
Conventional4Way Cassette S
By using the remote controller, the opening angles of the 4 blades can be individually
set at the same or different angles within a 32°- 65° range for more efficient cooling.
• Individual Blade Control
The check valve on the drain pump prevents drained water from flowing
backward into the drain pan. This minimizes the the drain pan’s water
level so that you will never have to worry about water stagnation or
overflowing drain water that could drip into your interior.
• No Overflowing Drain Water
ONE-WAY FLOW CLEAN CEILING NO STAGNATIONNO OVERFLOW
Check Valve:
Prevents drain water
from reversing
W
H
Minimizes
Remaining
Drain Water
INDOORUNITS
INDOORUNITS
4 WAY CASSETTE . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
2726
4 WAY CASSETTE FEATURES CONTINUED . . .
• Easy Leveling
Each corner portion of the panel is detachable: this makes it easier for you to
adjust the height, and makes installation and leveling much simpler and quicker.
• Easy Blade Cleaning
Samsung’s 4 Way Cassette indoor units have detachable air flow
blades so you don’t need to remove the entire panel to clean the
blades.
• Quick Cooling & Heating
Samsung’s 4 Way Cassette indoor unit achieves the desired
set temperature much faster than our competitor’s products.
0
1200
2400
3600
4800
6000
7200
8400
9600
10800
12000
23.5
22.0
20.5
19.0
17.5
16.0
14.5
13.0
11.5
10.0
2500
2000
1500
1000
500
0
1
2
0
0
2
4
0
0
3
6
0
0
4
8
0
0
6
0
0
0
7
2
0
0
8
4
0
0
Conventional
• Turbo Fan
High Ceiling Mode
• Fan Speed Adjustment for High Ceiling
The optimum fan speed for high ceiling can be achieved
just by using the remote controller without adjusting the
DIP switch on the indoor unit’s PCB. The fan speed
adjustment function provides evenly cool and warm air
throughout spaces with high ceiling of up to 11.5ft.
The high ceiling mode allows indoor units to provide
even more powerful airflow throughout your space.
This mode enlarges the coverage area of the airflow
up to a height of 15ft.
Fan Speed Adjustment
4 Way Cassette Conventional
Applied via
remote
controller
11.5ft
Not applied
8.5ft
15ft
12ft
High Ceiling Mode
Imagine a room of cool calmness. The aerodynamically
designed Turbo Fan minimizes noise from the turbulence
of the blade movement, meaning our units make less
noise than conventional models.
1. Silent Operation
2500
2000
1500
1000
500
0
1
2
0
0
2
4
0
0
3
6
0
0
4
8
0
0
6
0
0
0
7
2
0
0
8
4
0
0
0
1200
2400
3600
4800
6000
7200
8400
9600
10800
12000
23.5
22.0
20.5
19.0
17.5
16.0
14.5
13.0
11.5
10.0
SAMSUNG
Faster
25%Heating after approximately
30 minutes
Heating after approximately
40 minutes
The Turbo Fan with wide blades provides extreme cooling
and heating power from 4 separate outlets so the entire
room cools down or warms up faster. This unit can
extend comfort to every nook and cranny of the room.
2. Uniform Distribution
Conventional4Way
Samsung4Way
Conventional4Way
Samsung4Way
Conventional4Way
Samsung4Way
Conventional4Way
Samsung4Way
CFM
CAE
Analysis
Results
353
460
• Surround Air Flow
The 4 Way outlet can cool every portion of your room. The new and practical
design of the blades minimizes blind spots at the corners of the panel, and can
almost cover a full 360° around the indoor unit.
Covers 360O
INDOORUNITS
INDOORUNITS
4 WAY CASSETTE . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
2928
MINI 4 WAY CASSETTE
Available Capacities:
9,500 / 12,000 / 18,000 / 20,000 BTU
Wide blades in the indoor unit deliver cool or warm air
at greater distances to provide even cooling and heating
throughout the room.
• Powerful Airflow
1-Way Cassette
New Blade Conventional
4-Way Cassette
The newly designed panel will control air direction in a way
to avoid contact with the ceiling. This new design will prevent
dust from accumulating on the ceiling after long periods of
operation, keeping your interior space cleaner than ever.
• Ceiling Dust Prevention
Conventional Blade
Ceiling
PRODUCT FEATURES
The lift-up drain pump lifts condensed water up
to 29.5ft compared to our competitor’s limit of
27.5mm, making installation more flexible and
convenient.
• High-Lift Up Drain Pump
Company A
Lift-up Range
29.5ft
27.5ft
Fresh air can enter through the cassette unit so
you can enjoy even fresher air in your room.
• Fresh Air Intake
SAMSUNG
Fresh Air
Sub Duct enables you to use the same air
conditioner unit to cool an additional smaller
space nearby. (A cassette unit is fitted with a
knockout component to accommodate this).
• Sub Duct
The simple display design with its rounded corners adds a
neat and tidy feeling to your interior.
• Simple Display Power
Time
Defrost
Clean
Power
Defrost
Time
Clean
INDOORUNITS
INDOORUNITS
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
3130
• High-Lift Up Drain Pump
MINI 4 WAY CASSETTE FEATURES CONTINUED . . .
The Mini 4 Way Cassette can be installed on one standard ceiling tile
(23.6” x 23.6”), making installation more convenient.
• Ideal Compact Size
23.6”
24.5”
24.5”
The Mini 4 Way Cassette uses a new, neat and clean design. The
completely hermetic blade structure keeps the indoor unit clean
preventing dust or other foreign substances from entering the unit.
The internal parts of the indoor unit are also out of sight when the
blade is shut, improving the unit’s appearance.
• Neat and Clean Design
Not only is the Mini 4-Way Cassette compact enough to be installed on one
standard ceiling tile, it’s also lighter than a conventional mini 4 way cassette
(38.5lbs) by about 35% (24.3lbs).
• Compact and Light Unit
By using the remote controller, the opening angles of the 4 blades can be
individually set at the same or different angles within a 32°- 65° range for
more efficient cooling.
• Individual Blade Control
35%
38.5lbs24.3lbs
ConventionalMini 4 Way Cassette
• Motion Detector Sensor
The world’s first motion detector sensor for Samsung’s Mini 4 Way Cassette creates the ideal environment, saving energy by providing
the optimized amount of airflow when needed.
Power ON Power OFFThe Motion Detector Sensor detects when the user is
absent, automatically stopping the air conditioning. It
also automatically sets operation patterns to maximize
energy efficiency.
Energy Saving On/Off Function
The check valve on the drain pump prevents drained water from flowing
backward into the drain pan. This minimizes the the drain pan’s water
level so that you will never have to worry about water stagnation or
overflowing drain water that could drip into your interior.
• No Overflowing Drain Water
ONE-WAY FLOW CLEAN CEILING NO STAGNATIONNO OVERFLOW
Check Valve:
Prevents drain water
from reversing
W
H
Minimizes
Remaining
Drain Water
• Surround Air Flow
The 4 Way outlet can cool every portion of your room. The new and practical
design of the blades minimizes blind spots at the corners of the panel, and can
almost cover a full 360° around the indoor unit.
Covers 360O
INDOORUNITS
INDOORUNITS
MINI 4 WAY CASSETTE . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
3332
1 WAY CASSETTE
Available Capacities:
7,500 / 9,500 / 12,000 BTU
Wide blades in the indoor unit deliver cool or warm air
at greater distances to provide even cooling and heating
throughout the room.
• Powerful Airflow
1-Way Cassette
New Blade Conventional
4-Way Cassette
The newly designed panel will control air direction in a way to
avoid contact with the ceiling. This new design will prevent
dust from accumulating on the ceiling after long periods of
operation, keeping your interior space cleaner than ever.
• Ceiling Dust Prevention
Conventional Blade
Ceiling
PRODUCT FEATURES
The lift-up drain pump lifts condensed water up to 29.5ft
compared to our competitor’s limit of 27.5mm, making
installation more flexible and convenient.
• High-Lift Up Drain Pump
Company A
Lift-up Range
29.5ft
27.5ft
SAMSUNG
Samsung new blade design drastically reduces noise levels so you can relax
in peace and quiet.
• Quiet Operation
• Stylish and Aesthetic Panel
Samsung’s Slim 1Way Cassette provides a simple and refined design. The clean
lines and simple display design make this a modern classic, which looks great with
any interior.
Samsung is the first to apply ABS cabinets to its indoor units to provide
the lightest units on the market. This slim and lightweight design makes
installation and maintenance simple.
• Lighter Indoor Unit
Weight
21.8lbs
68lbs
Conventional
DVMS
25dB
30dB
Noiselevel
32%
Down
26%
Down
SAMSUNG
SAMSUNG
CompanyA
Low Fan Speed High Fan Speed
The check valve on the drain pump prevents drained water from flowing
backward into the drain pan. This minimizes the the drain pan’s water
level so that you will never have to worry about water stagnation or
overflowing drain water that could drip into your interior.
• No Overflowing Drain Water
ONE-WAY FLOW CLEAN CEILING NO STAGNATIONNO OVERFLOW
Check Valve:
Prevents drain water
from reversing
W
H
Minimizes
Remaining
Drain Water
INDOORUNITS
INDOORUNITS
1 WAY CASSETTE . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
3534
HSP DUCT
Available Capacities:
36,000 / 48,000 / 76,000 / 96,000 BTU
The HSP Duct’s Pre Filter traps dusts particles from the air.
• Pre Filter
PRODUCT FEATURES
After 1,000 hours of operation, the filter clean indicator will notify you that the filter should be cleaned.
The filter can be easily removed from the bottom, left, or right of the unit. (1,000 hours is the default set
time, which can be adjusted to 2,000 hours on the internal PCB).
• Easy Filter Cleaning
The Smart Pressure Control System adjusts fan speed
according to the external static pressure so the air
conditioner always provides you with consistent cooling
and heating power, regardless of the surrounding
environment.
• Smart Pressure Control
AirVolume
Static pressure
(inches of water)
Minimum Maximum
H
H
M
L
L
M
The HSP Ducted unit is controlled via a wired remote controller.
• Wired Remote Control
• High Lift-Up Drain Pump* (Optional)
The lift-up drain pump lifts condensed water up to
29.5”, compared to our competitor’s limit of 23.5”,
making installation more flexible and convenient.
Max:29.5”
Ceiling
* The lift-up range of the drain pump for the HSP
is limited to 18.5”.
To properly deal with unexpected and various installation conditions, the HSP
Duct is designed to manage high external static pressures up to .99” H2O.
• High External Static Pressure
.79” H2O
HSPDuct
HSPDuct
.99” H2O
3-4 TON 6-8 TON
Samsung’s HSP Duct features greater static pressure than most
slim ducts: enabling you to design more inlets and outlets with
longer duct work to provide even more cool or warm air to larger
areas.
• Large Coverage Area
.99” H.99” H2O.99” H2O.24” H.24” H2O.24” H2O
HSP DuctSlim Duct
INDOORUNITS
INDOORUNITS
HSP DUCT . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
3736
The external static pressure control makes it easy to design the
duct work to ensure efficiency and silent operation.
• Silent Operation with Static Pressure Control
HSP DUCT FEATURES CONTINUED . . .
Time and maintenance costs are reduced with parts being easily accessible.
• Easy to Maintain
MSP DUCT
Available Capacities:
18,000 / 24,000 / 30,000 / 36,000 / 48,000 BTU
PRODUCT FEATURES
The HSP Duct’s Pre Filter traps dusts particles from the air.
• Pre Filter
After 1,000 hours of operation, the filter clean indicator will notify you that the filter should be cleaned. The filter
can be easily removed from the bottom, left, or right of the unit. (1,000 hours is the default set time, which can
be adjusted to 2,000 hours on the internal PCB.)
• Easy Filter Cleaning
The Smart Pressure Control System adjusts fan speed
according to the external static pressure so the air
conditioner always provides you with consistent cooling
and heating power, regardless of the surrounding
environment.
• Smart Pressure Control
AirVolume
Static pressure
(inches of water)
Minimum Maximum
H
H
M
L
L
M
INDOORUNITS
INDOORUNITS
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
3938
MSP DUCT FEATURES CONTINUED . . .
Samsung’s MSP Duct is controlled via a wired remote controller.
• Wired Remote Control
• High Lift-Up Drain Pump (Optional)
The lift-up drain pump lifts condensed water up to
29.5”, compared to our competitor’s limit of 23.5”,
making installation more flexible and convenient.
Ceiling
Samsung’s MSP Duct features greater static pressure than most
slim ducts: enabling you to design more inlets and outlets with
longer duct work to provide even more cool or warm air to larger
areas.
• Large Coverage Area
.99” H.99” H2O.55” H2O.24” H.24” H2O.24” H2O
MSP DuctSlim Duct
The external static pressure control makes it easy to design the duct work
to ensure efficiency and silent operation.
• Silent Operation with Static Pressure Control
Max:29.5”
The MSP Duct has a very narrow width of 35.43”, making installation
and maintenance more flexible, maximizing your convenience.
• Narrow Width*
35.43”
*Measured without
control box
Parts are easily accessible, reducing the time for maintenance.
• Simple Maintenance
INDOORUNITS
INDOORUNITS
MSP DUCT . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
4140
SLIM DUCT
Available Capacities:
7,500 / 9,500 / 12,000 / 18,000 / 24,000 / 30,000 / 36,000 / 48,000 BTU
The Slim Duct’s Pre Filter traps dusts particles from the air.
• Pre Filter
PRODUCT FEATURES
After 1,000 hours of operation, the filter clean indicator will
notify you that the filter should be cleaned. The filter can be
easily removed from the bottom, left, or right of the unit.
(1,000 hours is the default set time, which can be adjusted
to 2,000 hours on the internal PCB.)
• Easy Filter Cleaning
The Smart Pressure Control System adjusts fan speed according to
the external static pressure so the air conditioner always provides
you with consistent cooling and heating power, regardless of the
surrounding environment.
• Smart Pressure Control
AirVolume
Static pressure
(inches of water)
Minimum Maximum
H
H
M
L
L
M
• High Lift-Up Drain Pump (Optional)
The lift-up drain pump lifts condensed water up to
29.5”, compared to our competitor’s limit of 23.5”,
making installation more flexible and convenient.
Max:29.5”
Ceiling
The Slim Duct is controlled via a wired remote controller.
• Wired Remote Control
The Slim Duct has a narrow width, which is 7.9” slimmer than conventional
products: this enables flexible installation and maintenance in various spaces.
• Compact Size
35.43”
27.56” 7.9”Slimmer
Samsung’s Slim Duct operates at a remarkably low sound level, lower
than the inside of a library, letting you enjoy comfort in a quiet and
peaceful environment.
• Quiet Operation
26dB
29dB
31dB
33dB
Noiselevel
11%
Down
6%
Down
SlimDuctS
Conventional
SlimDuctS
Conventional
Low Fan Speed High Fan Speed
INDOORUNITS
INDOORUNITS
SLIM DUCT . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
4342
SLIM DUCT FEATURES CONTINUED . . .
The Slim Duct is the lightest duct on the market, and is about 15%
lighter than our competitor’s products. This feature makes it
favorably easy and convenient to install and maintain.
• The Lightest Weight
The air inlet can be set up either on the bottom or rear of the unit, giving you more flexibility during installation.
• Flexible Installation
Weight
41.8lbs
50.7lbs
21%
Lighter
Slim Duct Conventional
TEX
Suction Duct
Diffuser
Diffuser
Suction Duct
TEX
Rear Side Air Inlet Bottom Side Air Inlet
Parts can be accessed simply by opening the bottom panel, simplifying maintenance.
• Easy to Maintain
The new drain pump can be installed from the side by simply removing the right side
panel. You no longer need to disassemble the top cover to install, check or repair the
drain pump.
• Easier Drain Pump Installation
HIGH WALL
Available Capacities:
7,500 / 9,500 / 12,000 / 18,000 / 20,000 / 24,000 BTU
PRODUCT FEATURES
Sleep with the air conditioner off, and it gets hot. Sleep with it on, and it gets too cold. With Samsung’s Good Sleep
Mode, you can stay comfortable because the room temperature automatically adjusts to your body temperature before,
during and after you sleep.
• Good Sleep Mode
INDOORUNITS
INDOORUNITS
Stage 01: Falling asleep
Eases you into sleep by dropping the temperature.
Stage 02: Sound asleep
Relaxes your body and raises your temperature slightly.
Stage 03: Wake up
You wake up to intermittent comfortable air, making you
feel refreshed and rested.
Falling asleep
01
Cooling mode
Sound sleep
02
Wake up
03
1 2 3 4 5 6 7 8
Time(hr.)
Heating mode
Till 1hr Till 8 hrs2 to 7 hrs
Best Temperature for Deep Sleep
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
4544
HIGH WALL FEATURES CONTINUED . . .
Incorporated with activated carbon, the deodorizing filter
efficiently absorbs cigarette smoke, pet odors and other
unpleasant smells.
• Deodorizing Filter
CEILING / FLOOR
Available Capacities:
18,000 / 24,000 BTU
PRODUCT FEATURES
The Pre Filter helps you stay comfortable by trapping dust
particles from the air.
• Pre Filter
Samsung’s Smart Inverter technology maintains the ideal temperature without the constant shutting off and on of
the compressor.
• Smart Inverter
Uncomfortable
(Energy Loss)
Uncomfortable
(Energy Loss)
Set Temperature
Comfortable
Smart Inverter automatically adjusts power to cope with
any variances, assuring you experience less temperature
fluctuations for optimal comfort.
Smart Inverter
Uncomfortable
(Energy Loss)
Uncomfortable
(Energy Loss)
Comfortable
Loss
Loss
Loss
Loss
Non Inverter
High Temperature
Fluctuation
Non inverter air conditioners shut off when the set temperature is
reached and turns back on when the temperature variance is high,
causing large fluctuations in temperature and comfort.
Non inverter
Mounted either on the floor or ceiling, the Ceiling/Floor
Mount unit blends well with any interior, enhancing the
decor and adding to the overall ambiance of the room.
• Interior Design
INDOORUNITS
INDOORUNITS
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
46
CEILING/FLOOR MOUNT FEATURES CONTINUED . . .
• Lightweight
INDOORUNITS
Depending on the available space and the purpose of the air conditioner, the indoor unit can be installed under the
ceiling or on the floor giving you flexibility and convenience.
• Flexible 2-Way Installation
Ceiling Floor
Because Samsung’s Ceiling/Floor Mount unit is light in weight, installation is more convenient
Samsung’s Ceiling/Floor Mount air conditioner boasts a slim, compact
design - half the size of our competitor’s with cooling power
comparable to our competitor’s larger products.
• Compact but Powerful
118%
CompanyA
200%
CompanyB
100%
SAMSUNG
123%
CompanyA
136%
CompanyB
100%
SAMSUNG
Smaller Lighter
Size Weight
CONTROLS
CONTROLS
INDIVIDUAL CONTROL CENTRAL CONTROL APPLICATIONSBUILDING MANAGEMENT
WIRED
REMOTE
CONTROL
Part No.
MC-A202DN
DMS 2
Part No.
MIM-DOOAN
WIRED REMOTE CONTROL
Part No. MWR-WE10N
WIRELESS REMOTE
CONTROL
Part No.
MWR-DH00U
EXTERNAL CONTACT
INTERFACE MODULE
Part No. MIM-B14
EXTERNAL
TEMP SENSOR
Part No.
MRW-TA
DUCT UNIT
WIRELESS
CONTROL
Part No.
MRK-A10N
BACnet
GATEWAY
Part No.
MIM-B17N
LonWorks
GATEWAY
Part No.
MIM-B18N
HEATPUMP
MODE
SELECTOR
SWITCH
Part No.
MC-C200
SNET 3 SOFTWARE
Part No. MST-P3P
ENERGY MANAGEMENT
Part No. MIM-B16N
S-CHECKER
iCONVERTER
Interface Module Watt-Hour Meter
S-NET mini Wireless Remote Controller
Wired Remote Controller
Wireless Remote ControllerCentrallized Controller
External Contact Interface Module
LonWorks Gateway
Wireless Remote Controller
PIM
DMS 2
47
Remote Control
Internet
Current
temp
°F
Desired
temp
°F
TOUCHSCREEN CONTROLLER
Part No. MCM-A300N
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
4948
WIRED REMOTE CONTROL
CONTROLS
INDIVIDUAL CONTROL
WIRELESS REMOTE CONTROL
• On/Off, Operation Mode, Fan Speed, Airflow, Temperature Setting
• Filter replacement alarm reset
• Simple schedule control
• Wide display
• Soft touch button
• Individual blade control (supports specific indoor unit models)
• Multi-channel wireless remote control (maximum of 4 channels)
MR-DH00U
CONTROLS
• External sensor to measure exact user environment temperature
• Wire length : 39ft.
MRW-TA
EXTERNAL TEMPERATURE SENSOR
• On/Off, Operation Mode, Fan Speed, Airflow, Temp Setting
• Individual and group control (maximum to 16 indoor units)
• Error display
• Filter replacement alarm reset
• Sleep & Silent mode
• Built-in room temperature sensor
• Child lock
• Automatic stop mode
• Wireless remote control restriction
• Clear & bright screen with LCD backlight
• Unified controller
• Different permission levels
• Weekly schedule setting
• Exception date setting
• Individual blade control (supports specific indoor unit models)
• Summer time
MWR-WE10N
Samsung’s MWR-WE10N wired controller allows connection of up to 16 Samsung indoor units. Features include:
built-in room sensor, air handler operation on/off, air handler operation mode, set temperature, air flow direction, fan
speed, discharge air temperature setting (with supported indoor unit models), quiet and sleep modes, error display,
filter replacement alarm display and reset, weekly operating schedule, different button permission levels, partial
button lock option, backlight, temperature limit setting option, service mode support, independent louver control for
DVM S series 4-way cassette models (AM0**FN4DCH), adjustable heating temperature compensation values, and
child lock.
• Direct indoor unit control by external contact signal
• Window-synchronized indoor unit control
• Emergency control with simple contact input
• Indoor unit operation / error state output through relay contacts
MIM-B14 (External Contact Interface Module)
GUESTROOM MANAGEMENT MODULE
Direct indoor unit ON/OFF control (a single evaporator) by external contact, 0 volts signal. Also provides operation
and error output terminals to control other devises/indicator lights with a dry-contact. E.G.: hotel key card switch,
door/window switch, PIR sensor with timed relay, other occupancy sensors, enabling/disabling other ventilation.
• On/Off control
• Operation indication
• Error Indication
• Filter replacement sign
• Use with receiver wire, MRW-10A
MRK-A10N
DUCT UNIT WIRELESS CONTROL
MRW-10A
(Wall-mounted Type Indoor Units : Only models that include EEV support state output function.)
On/Off
Key-Tag
On/Off
Window Open Sensor
Error
Malfunction Alarm
On/Off
External Device Control
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
51
CONTROLS
CENTRAL CONTROL
CONTROLS
ON/OFF CONTROLLER
MIM-D00AN
• Built-in web server for PC-independent management
and remote access control
• Multiple upper-level control access (S-NET 3,
Touchscreen Control, Web-client)
• Central management of up to 256 indoor units
• User editable control logic
• Accessible level management
• Dynamic security management
• Operation & error history management
• Weekly/Daily schedule control
• Power distribution function
• Current time management even during power failure
(for 24 hours)
• Data storage in non-volatile memory & SD memory
• Emergency stop function with simple contact interface
DMS 2
PIM Watt Hour Meter
Centralized Controller
Watt Hour MeterPIM
DMS 2 System
50
Standalone web server device that can connect to and control up to 256 indoor units via Internet Explorer. The DMS 2
provides a simple, easy to use interface for control of the following: indoor unit operation mode, temperature setting,
airflow direction, fan speed, temperature and mode limitations and restrictions, maximum current control of outdoor
unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or MIM-D00AN, heating and cooling
output calibration of indoor units, and other various control points. To fit the needs of the commercial building, multiple
user login accounts can be created with various levels of control for manager specified indoor units. The DMS 2 shall
also offer 10 Digital Input (2 reserved for system shutdown with emergency signal) and 8 Digital Output terminals (2
reserved) to control and monitor other devices on the project.• Maximum of 16 group controls (Maximum of 256 Indoor units)
• Unified/Individual indoor unit control (On/Off)
• Wireless/wired remote control restriction
• Cooling/Heating mode control
• Indoor unit error display
MC-A202DN
MCM-A202DN is a simple to use device that allows ON/OFF control of up to 128 indoor units with up to 16
individual groups. The MCM-A202DN also has a mode selection switch that allows easy system operation mode
changes along with ALL ON and ALL OFF buttons.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
5352
CONTROLS
CONTROLS
CENTRAL CONTROL
DMS 2 CONTINUED . . .
Air Conditioning Operation Monitoring
High Pressure
Fan Motor RPM
Current
Data
Time
Easy Control & Monitoring
• Control and monitoring of up to 256 indoor units
via internet network
• Operation On/Off
• Operation mode, fan speed, temperature setting
• No need to open each outdoor unit
• Detailed refrigerant flow check in control room
• Reduced service lead time
Anytime. Anywhere Control
Indoor Unit On/Off Time Storage
• Operation history data recorded for up to 6 months
Storage parameters
1. Indoor unit address and name
2. On/Off time (year, month, day, hour, minute)
3. Operation mode (Cool, Heat, Auto, Fan, Dry, Stop)
4. Set/Room temperatures
Storage Period - Up to 6 months
Flexible Connectivity
Administrator
User_A
User_B
User_C
User_D
Accessible Level Management
• It is possible to specify the scope of control and monitoring by each user.
Dynamic User Security Management
• General users, managers, and administrators can be registered
separately by ID and password. Administrators (utility
managers) have the authority to set access levels for DMS 2
functions on users.
Functions
Admin Manager User
Access All Changeable
Control / Monitoring O O O
Zone Management O O X
Schedule O O O
Power Distribution O O X
System Configuration O X X
• Indoor unit control via centralized controllers or
interface modules directly
• Select connection point according to the site
Small & Medium Size
Connect interface module only
Large Size
Connect centrallized controllers
DMS 2 . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
5554
CONTROLS
CONTROLS
CENTRAL CONTROL
DMS 2 CONTINUED . . .
Enhanced Graphical User Interface
Data Backup
• Important data is safely stored on SD memory card
Service Response
• Remote control and monitoring through the Internet (when a public IP is used)
• E-mail notification to private internet account in case of malfunction
User-friendly icon-based unit control
Zoom in & Zoom out icon display Convenient & stylish controller
Color indication and icons make it
easy to recognize indoor unit status
Current temp.
Desired temp.
Current temp.
Desired temp.
68° F
74° F
68° F
74° F
68° F
74° F68° F
74° F
1. Indoor/outdoor unit name
2. Power distribution data
3. Operation history (On/Off by DMS)
4. DMS power On/Off history
5. System configuration
6. Others
Automatic system
recovery after Service
DMS 2 . . .
User Editable Control Logic
• User can edit control logic with arithmetic / conditional operators and parameters
• Energy can be efficiently used and reduced for various operation conditions
Example : Energy saving function, operation adjustment depending on outdoor temperature
EHP / ERV / AHU
Parameters
Arithmetic Equation
FunctionAND
OR
EHP / ERV / AHU
Parameters change
......deepsnaF,edoM,rewoP,pmetgnitteSegarevA,<=,>=,=,>,<......edoM,rewoP,erutarepmeT
Logic Outdoor temp < Room temp
Control Turn ON ERV
Outdoor temp < 50°F
Heating mode Cooling mode
Room
Outdoor
WINTER SUMMER
Room temp < Outdoor temp
(Cool air Intake UP) Turn ON Air Conditioner
Useful History Management
• DMS 2 records indoor unit operation and error
occurrence history.
• Recorded history makes it convenient to analyze
air conditioner operation and perform unit maintenance.
1. Operation On/Off execution time
2. Daily accumulated operation On time
3. Schedule operation execution time
Operation History
1. Error occurred unit name
2. Error details
3. Error occurrence/clear time
4. Error state (solved / unsolved)
Error History
Outdoor temp > 75°F
More Extended Contact Interface
General users, managers, and administrators can be registered
separately by ID and password. Administrators (utility managers)
have the ability to set access levels for DMS 2 functions on users. Building Control System
Fire Control System
Operation Restriction
Error Status Indicator
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
5756
CONTROLS
CONTROLS
CENTRAL CONTROL
DMS 2 CONTINUED . . .
Power Distribution System
• Power distribution to a maximum of 256 indoor units
• Data query for watt-hour, usage time and usage ratio
• Files are saved in Microsoft® Excel® format
• 1-year power distribution data is saved in storage
• Current actual power consumption monitoring
• Current-type electricity meter support (CT ratio input)
140kWh
5th Floor
610kWh
4th Floor
460kWh
3rd Floor
360kWh
2nd Floor
180kWh
1st Floor
Indoor Unit Operation State
1. Operation Data Accumulation
and Power Distribution
2. Data Extract
- Excel Format
Smart Central Management
• Control & monitoring zone edition
• Wireless/wired remote control restriction
• Temperature limit setting
• Operation mode restriction
Cooling only / No remote controller / Minimum
cooling temperature setting is 68°F
Cooling only / Remote controller useB Zone
A Zone A Zone
B Zone
BACnet GATEWAY
MIM-B17N (DMS-Bnet)
• Interface for BACnet management system
• Maximum 256 indoor units plus ERVs support with a maximum of
80 interface modules
• Combinational use of BACnet and S-NET 3/ S-NET Mini
• Includes DMS 2 functions
• On/Off control
• Operation mode
• Temperature setting
• Fan speed/direction
• ERV operation mode
• ERV fan speed
• Filter alarm reset
• User control restriction
• Operation mode lock
• Set temperature limit
• Emergency stop
• Output contact control
CONTROL
• On/Off control
• Operation mode
• Set/Room temperature
• Fan speed/direction
• ERV operation mode
• ERV fan speed
• Filter alarm
• User control restriction
• Thermo On/Off
• Power distribution
• Operation mode lock
• Set temperature limit
• In/Out contact state
• Emergency stop
• Error code
MONITORING
BACnet Gateway Setup
Ethernet
RS485
Ethernet
BACnet Gateway
Standalone web server device that can connect to and control up to 256 indoor units via Internet Explorer. The MIM-B17 provides
a simple, easy to use interface for control of the following: indoor unit operation mode, temperature setting, airflow direction, fan
speed, temperature and mode limitations and restrictions, maximum current control of outdoor unit(s) to limit current (50%
- 100% of design current) adjustable at outdoor unit or MIM-B17, heating and cooling output calibration of indoor units, and
other various control points. To fit the needs of the commercial building, multiple user login accounts can be created with various
levels of control for manager specified indoor units. The MIM-B17 shall also offer 10 Digital Input (2 reserved for system
shutdown with emergency signal) and 8 Digital Output terminals (2 reserved) to control and monitor other devices on the project.
The MIM-B17 will also interface with BACnet systems to allow full integration with building management systems.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
5958
CONTROLS
CONTROLS
CENTRAL CONTROL
LonWorks GATEWAY
MIM-B18N (DMS-Lnet)
• Interface for Lon-Connection to LonWorks management system
• Max. 128 indoor units plus ERVs support with a maximum of
80 interface modules
• Works with LonWorks and S-NET 3
• Includes DMS 2 functions
• On/Off control
• Operation mode
• Set/Room temperature
• Fan speed/direction
• ERV operation mode
• ERV fan speed
• Filter alarm
• User control restriction
• Thermo On/Off
• Power distribution
• Operation mode lock
• Set temperature limit
• In/Out contact state
• Emergency stop
• Error code
MONITORING
LonWorks Gateway Setup
Ethernet
RS485
FTT-10A
LonWorks BMS
CONTROL
• On/Off control
• Operation mode
• Temperature setting
• Fan speed/direction
• ERV operation mode
• ERV fan speed
• Filter alarm reset
• User control restriction
• Operation mode lock
• Set temperature limit
• Emergency stop
• Output contact control
HEAT PUMP MODE SELECTOR SWITCH
• Operation mode selection (Cooling, Heating or Auto)
• Mixed operation mode protection
MC-C200
Standalone web server device that can connect to and control up to 128 indoor units via Internet Explorer. The MIM-B18 provides
a simple, easy to use interface for control of the following: indoor unit operation mode, temperature setting, airflow direction, fan
speed, temperature and mode limitations and restrictions, maximum current control of outdoor unit(s) to limit current (50%
- 100% of design current) adjustable at outdoor unit or MIM-B18, heating and cooling output calibration of indoor units, and
other various control points. To fit the needs of the commercial building, multiple user login accounts can be created with various
levels of control for manager specified indoor units. The MIM-B18 shall also offer 10 Digital Input (2 reserved for system
shutdown with emergency signal) and 8 Digital Output terminals (2 reserved) to control and monitor other devices on the project.
The MIM-B18 will also interface with LonWorks systems to allow full integration with building management systems.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
6160
TOUCHSCREEN CONTROLLER
Control and Monitoring
CONTROLS
MCM-A300M*
• Control & monitoring of up to 256 indoor units
• Operation control and monitoring
• Detailed operation cycling information monitoring
• Wireless/Wired remote control restriction setting
CONTROLS
The Touchscreen Controller supports up to 4 DMS 2’s to provide the same remote control functions as the S-NET 3. It can be
directly connected to the system air conditioner through the centralized controller or interface modules, allowing for the control
of up to 256 indoor units.
Current
temp
°F
Desired
temp
°F
*Touchscreen controller may be updated and have a different appearance than
shown above. Due to ongoing product development, some features for the
MCM-A300N may change without prior notice.
• Flexible compatibility options (DMS 2, centralized
controller)
• Central management of up to 256 indoor units
• Detailed cycling information monitoring
• Schedule function (Weekly, Daily)
• USB keyboard support
• Error display
• LCD display
• Temperature limit setting
• Touch screen
• Zone control
• Child-lock setting
• Operation mode lock
• External contact control
Supports 4
Current
temp
°F
Desired
temp
°F
Supports 16
Centrallized
Controllers
MCM-A300M
MCM-A300N Setup
Current
temp
°F
Desired
temp
°F
Schedule Control
• Maximum 256 Weekly, Daily schedule control
• Schedule repetition, exception date setting
• Schedule edit (add, edit, delete)
• Detailed operation schedule setting
• Remote control restriction option setting
Zone Management
• Management structure customization regardless
of installation structure
• Control zone creation/edition/deletion
Central Restriction Function
• Upper/Lower temperature limit setting
• Operation mode lock
°F °F
Cycle Monitoring
• Monitoring outdoor/indoor unit cycle data
(The monitoring function is supported for
specific outdoor unit models)
Error Management
• Error history management
• Error management information query
• Detailed error information query
CENTRAL CONTROL
TOUCHSCREEN CONTROLLER . . .
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
6362
S-NET 3
CONTROLS
• Fully integrated PC management software
• Up to 16 DMS 2 connections through the Internet
• Central management of up to 4,096 indoor units
• Schedule/Zone control
• Error/Operation history management
• Power distribution management and analysis
MST-P3P
Supports16
CONTROLS
S-NET 3 System
Centralized
Controller
SNET 3 . . .
Samsung Software that allows monitoring and control of up to 16 DMS 2’s, Samsung BACnet Gateways, or Samsung
LonWorks gateways via LAN connection. SNET 3 provides a simple, easy to use interface for control of the following:
indoor unit operation mode, temperature setting, airflow direction, fan speed, temperature and mode limitations and
restrictions, gateway Digital Inputs and Digital Outputs, and other various control points. To fit the needs of the
commercial building, multiple user login accounts can be created with various levels of control for manager specified
indoor units. SNET 3 shall also offer energy management query for tenant billing and energy reports (other
components necessary). SNET 3 offers a single point for control for a single building or multiple buildings via public
IP.
Control and Monitoring
• Control & monitoring of up to 4,096 indoor units
• Wireless/Wired remote control restriction
• Temperature limit setting
• Operation mode lock
• Multiple/Full indoor unit selection
• Icon-based indoor unit display mode
Power Distribution Management
• Data query for power distribution and operation time
• Power distribution report generation and printing
• Time section setting for different electricity rates
• Group setting for power distribution summary
Schedule Control
• Graphical schedule settings
• Weekly, Daily schedule control
• Exception date setting
History Management
• Error/Event history management
• Indoor unit operation history management
• Report generation and printing
Zone Management
• Management structure customization regardless
of installation structure
• Control zone creation/edition/deletion
• Tree structure zone management control
Cycle Monitoring
• Monitoring outdoor/indoor unit cycle data
(The monitoring function is supported for specific
outdoor unit models)
BUILDING MANAGEMENT
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
6564
CONTROLS
CONTROLS
BUILDING MANAGEMENT
WATT-HOUR METER INTERFACE MODULE
MIM-B16N (Pulse Input Module)
• Exclusive use for DMS 2 power distribution
• Connection with up to 8 watt-hour meters
• Pulse interface with watt-hour meters
• Power consumption display for each watt-hour meter
The Watt-Hour Meter Interface Module can be exclusively used
for DMS 2 power distribution, displaying power consumption for
each watt-hour meter.
Pulse Input Module Setup
Supports Max.8
Supports Max.8
Pulse Input
Module (PIM)
Pulse Input
Module (PIM)
Centralized Controllers
PIM
Watt Hour
Meters
ShortShort Short
Open Open
More than 3ms (mandatory)
APPLICATIONS
S-CHECKER
With S-Checker, DVM S can be monitored by smart devices
such as smart phone or tablet PC. Facilitates self-diagnosis,
auto commissioning, auto management, and mobile data
transmission.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
6766
DVM PRO
DVM Pro is a selection program that allows you to design your DVM S system with ease and precision.
Sales Mode
• Indoor Unit & Outdoor Unit : Indoor unit and outdoor unit connection with accessories
• Piping : Basic or manual selection with system check and capacity simulation
• Wiring : Automatic diagram with communication wiring of indoor/outdoor/control units and electric
power meters
• Control system: Automatic control unit selection
• Report : Specifications, diagrams with DWG & BMP format, quotation
CAD Mode
• Quick, Easy, Precise Design
• AutoCAD add-on software (AutoCAD is not included with DVM-Pro)
• Automatic Calculation : Refrigerant & drain pipe size
• Automatic Selection : Refnet joint, header & distributor kit
• System Check : Installation regulation & refrigerant addition
• Easy Control System Selection
• Automatic Report : Piping installation diagram, equipment list & quotation
DVM Pro can be downloaded at www.samsungdvm-s.com or www.dvmdownload.com
NOTES
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
6968
SPECIFICATIONS - OUTDOOR UNITS
SPECIFICATIONS
SPECIFICATIONS
Model Name AM072FXVAFH/AA AM096FXVAFH/AA AM120FXVAFH/AA AM144FXVAFH/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP
Performance
Ton TON 6.00 8.00 10.00 12.00
Capacity
(Nominal)
Cooling1)
Btu/h 72,000 96,000 120,000 144,000
Heating1)
Btu/h 81,000 108,000 135,000 162,000
Capacity
(Rated)
Cooling Btu/h 69,000 92,000 114,000 138,000
Heating Btu/h 77,000 103,000 129,000 154,000
Power
MCA A 28 37.8 43 52.6
MOP A 35 50 50 70
Compressor
Type - SSC Scroll x 1 SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2
Output kW × n (4.96) (4.96x2) (4.96x2) (4.96x2)
Model Name - DS-GB052FBVASG x 1 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 1100 2200 2200 2200
fl. oz. 77.77 155.54 155.54 155.54
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W 400 x 1 620 x 2 620 x 2 620 x 2
Air Flow Rate CFM 7,239.78 9,182.16 9,182.16 9,535.32
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 9.52 9.52 12.70 12.70
Ø, inch 3/8 3/8 1/2 1/2
Gas Pipe
Ø, mm 19.05 22.22 28.58 28.58
Ø, inch 3/4 7/8 1 1/8 1 1/8
High Pressure Gas Pipe (for HR)
Ø, mm - - - -
Ø, inch - - - -
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 5.50 7.40 7.40 8.70
lbs 12.13 16.31 16.31 19.18
Sound2)
Sound Pressure
dB(A)
60.0 61.0 61.0 62.0
Sound Power 81 81 81 83
External
Dimension
Net Weight
kg 190.0 278.0 278.0 293.0
lbs 418.88 612.89 612.89 645.95
Shipping Weight
kg 206.0 300.0 300.0 312.0
lbs 454.15 661.39 661.39 687.84
Net Dimensions (WxHxD)
mm 880 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765
inch 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12
Shipping Dimensions (WxHxD)
mm 948 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832
inch 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
DVM S HEAT PUMP (208~230V)
Model Name AM168FXVAFH/AA AM192FXVAFH/AA AM216FXVAFH/AA AM240FXVAFH/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP
Performance
Ton TON 14.00 16.00 18.00 20.00
Capacity
(Nominal)
Cooling1)
Btu/h 168,000 192,000 216,000 240,000
Heating1)
Btu/h 189,000 216,000 243,000 270,000
Capacity
(Rated)
Cooling Btu/h 161,000 183,000 207,000 228,000
Heating Btu/h 180,000 206,000 231,000 258,000
Power
MCA A 65.8 71 80.6 86
MOP A 85 85 105 100
Compressor
Type - SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 4
Output kW × n (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2)x2
Model Name - DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 4
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 3300 3300 3300 4400
fl. oz. 233.32 233.32 233.32 311.09
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W 620 x 2 + 400 x 1 620 x 2 + 400 x 1 620 x 2 + 400 x 1 (620 x 2) x 2
Air Flow Rate CFM 9,182.16 + 7,239.78 9,182.16 + 7,239.78 9,535.32 + 7,239.78 9,182.16 x 2
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 15.88 15.88 15.88 15.88
Ø, inch 5/8 5/8 5/8 5/8
Gas Pipe
Ø, mm 28.58 28.58 28.58 28.58
Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8
High Pressure Gas Pipe (for HR)
Ø, mm - - - -
Ø, inch - - - -
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 12.90 12.90 14.20 14.80
lbs 28.44 28.44 31.31 32.63
Sound2)
Sound Pressure
dB(A)
- - - -
Sound Power - - - -
External
Dimension
Net Weight
kg 278.0 + 190.0 278.0 + 190.0 293.0 + 190.0 278.0 x 2
lbs 612.89 + 418.88 612.89 + 418.88 645.95 + 418.88 612.89 x 2
Shipping Weight
kg 300.0 + 206.0 300.0 + 206.0 312.0 + 206.0 300.0 x 2
lbs 661.39 + 454.15 661.39 + 454.15 687.84 + 454.15 661.39 x 2
Net Dimensions (WxHxD)
mm
1,295 x 1,695 x 765 +
880 x 1,695 x 765
1,295 x 1,695 x 765 +
880 x 1,695 x 765
1,295 x 1,695 x 765 +
880 x 1,695 x 765
(1,295 x 1,695 x 765)
x 2
inch
50.98 x 66.73 x 30.12 +
34.65 x 66.73 x 30.12
50.98 x 66.73 x 30.12 +
34.65 x 66.73 x 30.12
50.98 x 66.73 x 30.12 +
34.65 x 66.73 x 30.12
(50.98 x 66.73 x 30.12)
x 2
Shipping Dimensions (WxHxD)
mm
1,363 x 1,912 x 832 +
948 x 1,912 x 832
1,363 x 1,912 x 832 +
948 x 1,912 x 832
1,363 x 1,912 x 832 +
948 x 1,912 x 832
(1,363 x 1,912 x 832)
x 2
inch
53.66 x 75.28 x 32.76 +
37.32 x 75.28 x 32.76
53.66 x 75.28 x 32.76 +
37.32 x 75.28 x 32.76
53.66 x 75.28 x 32.76 +
37.32 x 75.28 x 32.76
(53.66 x 75.28 x 32.76)
x 2
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
DVM S HEAT PUMP (208~230V)
OUTDOOR UNITS
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
7170
SPECIFICATIONS - OUTDOOR UNITS
SPECIFICATIONS
SPECIFICATIONS
DVM S HEAT PUMP (208~230V) DVM S HEAT PUMP (208~230V)
OUTDOOR UNITS
Model Name AM264FXVAFH/AA AM288FXVAFH/AA AM312FXVAFH/AA AM336FXVAFH/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP
Performance
Ton TON 22.00 24.00 26.00 28.00
Capacity
(Nominal)
Cooling1)
Btu/h 264,000 288,000 312,000 336,000
Heating1)
Btu/h 297,000 324,000 351,000 378,000
Capacity
(Rated)
Cooling Btu/h 252,000 276,000 299,000 321,000
Heating Btu/h 283,000 308,000 334,000 360,000
Power
MCA A 95.6 105.2 118.4 123.6
MOP A 120 140 155 155
Compressor
Type - SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 5 SSC Scroll x 5
Output kW × n (4.96x2) + (4.96x2) (4.96x2)x2 (4.96x2) + (4.96x2) + (4.96) (4.96x2) + (4.96x2) + (4.96)
Model Name - DS-GB052FBVASG x 4 DS-GB052FBVASG x 4 DS-GB052FBVASG x 5 DS-GB052FBVASG x 5
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 4400 4400 5500 5500
fl. oz. 311.09 311.09 388.86 388.86
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W (620 x 2) x 2 (620 x 2) x 2 (620 x 2) x 2 + 400 x 1 (620 x 2) x 2 + 400 x 1
Air Flow Rate CFM 9,182.16 + 9,535.32 9,535.32 x 2
9,182.16 + 9,535.32 +
7,239.78
9,182.16 + 9,535.32 +
7,239.78
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 19.05 19.05 19.05 19.05
Ø, inch 3/4 3/4 3/4 3/4
Gas Pipe
Ø, mm 34.92 34.92 34.92 34.92
Ø, inch 1 3/8 1 3/8 1 3/8 1 3/8
High Pressure Gas Pipe (for HR)
Ø, mm - - - -
Ø, inch - - - -
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 16.10 17.40 21.60 21.60
lbs 35.49 38.36 47.62 47.62
Sound2)
Sound Pressure
dB(A)
- - - -
Sound Power - - - -
External
Dimension
Net Weight
kg 278.0 + 293.0 293.0 x 2 278.0 + 293.0 + 190.0 278.0 + 293.0 + 190.0
lbs 612.89 + 645.95 645.95 x 2
612.89 + 645.95 +
418.88
612.89 + 645.95 +
418.88
Shipping Weight
kg 300.0 + 312.0 312.0 x 2 300.0 + 312.0 + 206.0 300.0 + 312.0 + 206.0
lbs 661.39 + 687.84 687.84 x 2
661.39 + 687.84 +
454.15
661.39 + 687.84 +
454.15
Net Dimensions (WxHxD)
mm (1,295 x 1,695 x 765)
x 2
(1,295 x 1,695 x 765)
x 2
(1,295 x 1,695 x 765) x 2
+ 880 x 1,695 x 765
(1,295 x 1,695 x 765) x 2
+ 880 x 1,695 x 765
inch
(50.98 x 66.73 x 30.12)
x2
(50.98 x 66.73 x 30.12)
x2
(50.98 x 66.73 x 30.12) x 2
+ 34.65 x 66.73 x 30.12
(50.98 x 66.73 x 30.12) x 2
+ 34.65 x 66.73 x 30.12
Shipping Dimensions (WxHxD)
mm
(1,363 x 1,912 x 832)
x 2
(1,363 x 1,912 x 832)
x 2
(1,363 x 1,912 x 832) x 2
+ 948 x 1,912 x 832
(1,363 x 1,912 x 832) x 2
+ 948 x 1,912 x 832
inch
(53.66 x 75.28 x 32.76)
x2
(53.66 x 75.28 x 32.76)
x2
(53.66 x 75.28 x 32.76) x 2
+ 37.32 x 75.28 x 32.76
(53.66 x 75.28 x 32.76) x 2
+ 37.32 x 75.28 x 32.76
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
Model Name AM360FXVAFH/AA AM384FXVAFH/AA AM408FXVAFH/AA AM432FXVAFH/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP
Performance
Ton TON 30.00 32.00 34.00 36.00
Capacity
(Nominal)
Cooling1)
Btu/h 360,000 384,000 408,000 432,000
Heating1)
Btu/h 405,000 432,000 459,000 486,000
Capacity
(Rated)
Cooling Btu/h 345,000 366,000 390,000 414,000
Heating Btu/h 385,000 412,000 437,000 462,000
Power
MCA A 133.2 138.6 148.2 157.8
MOP A 175 170 190 210
Compressor
Type - SSC Scroll x 5 SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6
Output kW × n (4.96x2)x2 + (4.96) (4.96x2)x2 + (4.96x2) (4.96x2) + (4.96x2)x2 (4.96x2)x3
Model Name - DS-GB052FBVASG x 5 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 5500 6600 6600 6600
fl. oz. 388.86 466.63 466.63 466.63
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W (620 x 2) x 2 + 400 x 1 (620 x 2) x 3 (620 x 2) x 3 (620 x 2) x 3
Air Flow Rate CFM 9,535.32 x 2 + 7,239.78 9,182.16 x 2 + 9,535.32 9,182.16 + 9,535.32 x 2 9,535.32 x 3
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 19.05 19.05 19.05 19.05
Ø, inch 3/4 3/4 3/4 3/4
Gas Pipe
Ø, mm 41.28 41.28 41.28 41.28
Ø, inch 1 5/8 1 5/8 1 5/8 1 5/8
High Pressure Gas Pipe (for HR)
Ø, mm - - - -
Ø, inch - - - -
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 22.90 23.50 24.80 26.10
lbs 50.49 51.81 54.67 57.54
Sound2)
Sound Pressure
dB(A)
- - - -
Sound Power - - - -
External
Dimension
Net Weight
kg 293.0 x 2 + 190.0 278.0 x 2 + 293.0 278.0 + 293.0 x 2 293.0 x 3
lbs 645.95 x 2 + 418.88 612.89 x 2 + 645.95 612.89 + 645.95 x 2 645.95 x 3
Shipping Weight
kg 312.0 x 2 + 206.0 300.0 x 2 + 312.0 300.0 + 312.0 x 2 312.0 x 3
lbs 687.84 x 2 + 454.15 661.39 x 2 + 687.84 661.39 + 687.84 x 2 687.84 x 3
Net Dimensions (WxHxD)
mm
(1,295 x 1,695 x 765) x 2
+ 880 x 1,695 x 765
(1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3
inch
(50.98 x 66.73 x 30.12) x
2 + 34.65 x 66.73 x 30.12
(50.98 x 66.73 x 30.12) x
3
(50.98 x 66.73 x 30.12) x
3
(50.98 x 66.73 x 30.12) x
3
Shipping Dimensions (WxHxD)
mm
(1,363 x 1,912 x 832) x 2
+ 948 x 1,912 x 832
(1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3
inch
(53.66 x 75.28 x 32.76) x 2
+ 37.32 x 75.28 x 32.76
(53.66 x 75.28 x 32.76) x
3
(53.66 x 75.28 x 32.76) x
3
(53.66 x 75.28 x 32.76) x
3
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
7372
SPECIFICATIONS - OUTDOOR UNITS
SPECIFICATIONS
SPECIFICATIONS
DVM S HEAT RECOVERY (208~230V) DVM S HEAT RECOVERY (208~230V)
OUTDOOR UNITS
Model Name AM072FXVAFR/AA AM096FXVAFR/AA AM120FXVAFR/AA AM144FXVAFR/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY
Performance
Ton TON 6.00 8.00 10.00 12.00
Capacity
(Nominal)
Cooling1)
Btu/h 72,000 96,000 120,000 144,000
Heating1)
Btu/h 81,000 108,000 135,000 162,000
Capacity
(Rated)
Cooling Btu/h 69,000 92,000 114,000 138,000
Heating Btu/h 77,000 103,000 129,000 154,000
Power
MCA A 28 37.8 43 52.6
MOP A 35 50 50 70
Compressor
Type - SSC Scroll x 1 SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2
Output kW × n (4.96) (4.96x2) (4.96x2) (4.96x2)
Model Name - DS-GB052FBVASG x 1 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 1100 2200 2200 2200
fl. oz. 77.77 155.54 155.54 155.54
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W 400 x 1 620 x 2 620 x 2 620 x 2
Air Flow Rate CFM 7,239.78 9,182.16 9,182.16 9,535.32
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 9.52 9.52 12.70 12.70
Ø, inch 3/8 3/8 1/2 1/2
Gas Pipe
Ø, mm 19.05 22.22 28.58 28.58
Ø, inch 3/4 7/8 1 1/8 1 1/8
High Pressure Gas Pipe (for HR)
Ø, mm 15.88 19.05 22.22 22.22
Ø, inch 5/8 3/4 7/8 7/8
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 5.50 7.40 7.40 8.70
lbs 12.13 16.31 16.31 19.18
Sound2)
Sound Pressure
dB(A)
60.0 61.0 61.0 62.0
Sound Power 81 81 81 83
External
Dimension
Net Weight
kg 190.0 278.0 278.0 293.0
lbs 418.88 612.89 612.89 645.95
Shipping Weight
kg 206.0 300.0 300.0 312.0
lbs 454.15 661.39 661.39 687.84
Net Dimensions (WxHxD)
mm 880 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765
inch 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12
Shipping Dimensions (WxHxD)
mm 948 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832
inch 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
Model Name AM168FXVAFR/AA AM192FXVAFR/AA AM216FXVAFR/AA AM240FXVAFR/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY
Performance
Ton TON 14.00 16.00 18.00 20.00
Capacity
(Nominal)
Cooling1)
Btu/h 168,000 192,000 216,000 240,000
Heating1)
Btu/h 189,000 216,000 243,000 270,000
Capacity
(Rated)
Cooling Btu/h 161,000 183,000 207,000 228,000
Heating Btu/h 180,000 206,000 231,000 258,000
Power
MCA A 65.8 71 80.6 86
MOP A 85 85 105 100
Compressor
Type - SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 4
Output kW × n (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2)x2
Model Name - DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 4
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 3300 3300 3300 4400
fl. oz. 233.32 233.32 233.32 311.09
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W 620 x 2 + 400 x 1 620 x 2 + 400 x 1 620 x 2 + 400 x 1 (620 x 2) x 2
Air Flow Rate CFM 9,182.16 + 7,239.78 9,182.16 + 7,239.78 9,535.32 + 7,239.78 9,182.16 x 2
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 15.88 15.88 15.88 15.88
Ø, inch 5/8 5/8 5/8 5/8
Gas Pipe
Ø, mm 28.58 28.58 28.58 28.58
Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8
High Pressure Gas Pipe (for HR)
Ø, mm 22.22 28.58 28.58 28.58
Ø, inch 7/8 1 1/8 1 1/8 1 1/8
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 12.90 12.90 14.20 14.80
lbs 28.44 28.44 31.31 32.63
Sound2)
Sound Pressure
dB(A)
- - - -
Sound Power - - - -
External
Dimension
Net Weight
kg 278.0 + 190.0 278.0 + 190.0 293.0 + 190.0 278.0 x 2
lbs 612.89 + 418.88 612.89 + 418.88 645.95 + 418.88 612.89 x 2
Shipping Weight
kg 300.0 + 206.0 300.0 + 206.0 312.0 + 206.0 300.0 x 2
lbs 661.39 + 454.15 661.39 + 454.15 687.84 + 454.15 661.39 x 2
Net Dimensions (WxHxD)
mm
1,295 x 1,695 x 765 +
880 x 1,695 x 765
1,295 x 1,695 x 765 +
880 x 1,695 x 765
1,295 x 1,695 x 765 +
880 x 1,695 x 765
(1,295 x 1,695 x 765) x 2
inch
50.98 x 66.73 x 30.12 +
34.65 x 66.73 x 30.12
50.98 x 66.73 x 30.12 +
34.65 x 66.73 x 30.12
50.98 x 66.73 x 30.12 +
34.65 x 66.73 x 30.12
(50.98 x 66.73 x 30.12) x
2
Shipping Dimensions (WxHxD)
mm
1,363 x 1,912 x 832 +
948 x 1,912 x 832
1,363 x 1,912 x 832 +
948 x 1,912 x 832
1,363 x 1,912 x 832 +
948 x 1,912 x 832
(1,363 x 1,912 x 832) x 2
inch
53.66 x 75.28 x 32.76 +
37.32 x 75.28 x 32.76
53.66 x 75.28 x 32.76 +
37.32 x 75.28 x 32.76
53.66 x 75.28 x 32.76 +
37.32 x 75.28 x 32.76
(53.66 x 75.28 x 32.76) x
2
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
7574
SPECIFICATIONS - OUTDOOR UNITS
SPECIFICATIONS
SPECIFICATIONS
DVM S HEAT RECOVERY (208~230V) DVM S HEAT RECOVERY (208~230V)
OUTDOOR UNITS
Model Name AM264FXVAFR/AA AM288FXVAFR/AA AM312FXVAFR/AA AM336FXVAFR/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY
Performance
Ton TON 22.00 24.00 26.00 28.00
Capacity
(Nominal)
Cooling1)
Btu/h 264,000 288,000 312,000 336,000
Heating1)
Btu/h 297,000 324,000 351,000 378,000
Capacity
(Rated)
Cooling Btu/h 252,000 276,000 299,000 321,000
Heating Btu/h 283,000 308,000 334,000 360,000
Power
MCA A 95.6 105.2 118.4 123.6
MOP A 120 140 155 155
Compressor
Type - SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 5 SSC Scroll x 5
Output kW × n (4.96x2) + (4.96x2) (4.96x2)x2
(4.96x2) + (4.96x2) +
(4.96)
(4.96x2) + (4.96x2) +
(4.96)
Model Name - DS-GB052FBVASG x 4 DS-GB052FBVASG x 4 DS-GB052FBVASG x 5 DS-GB052FBVASG x 5
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 4400 4400 5500 5500
fl. oz. 311.09 311.09 388.86 388.86
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W (620 x 2) x 2 (620 x 2) x 2 (620 x 2) x 2 + 400 x 1 (620 x 2) x 2 + 400 x 1
Air Flow Rate CFM 9,182.16 + 9,535.32 9,535.32 x 2
9,182.16 + 9,535.32 +
7,239.78
9,182.16 + 9,535.32 +
7,239.78
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 19.05 19.05 19.05 19.05
Ø, inch 3/4 3/4 3/4 3/4
Gas Pipe
Ø, mm 34.92 34.92 34.92 34.92
Ø, inch 1 3/8 1 3/8 1 3/8 1 3/8
High Pressure Gas Pipe (for HR)
Ø, mm 28.58 28.58 28.58 28.58
Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 16.10 17.40 21.60 21.60
lbs 35.49 38.36 47.62 47.62
Sound2)
Sound Pressure
dB(A)
- - - -
Sound Power - - - -
External
Dimension
Net Weight
kg 278.0 + 293.0 293.0 x 2 278.0 + 293.0 + 190.0 278.0 + 293.0 + 190.0
lbs 612.89 + 645.95 645.95 x 2
612.89 + 645.95 +
418.88
612.89 + 645.95 +
418.88
Shipping Weight
kg 300.0 + 312.0 312.0 x 2 300.0 + 312.0 + 206.0 300.0 + 312.0 + 206.0
lbs 661.39 + 687.84 687.84 x 2
661.39 + 687.84 +
454.15
661.39 + 687.84 +
454.15
Net Dimensions (WxHxD)
mm (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2
(1,295 x 1,695 x 765) x 2
+ 880 x 1,695 x 765
(1,295 x 1,695 x 765) x 2
+ 880 x 1,695 x 765
inch
(50.98 x 66.73 x 30.12) x
2
(50.98 x 66.73 x 30.12) x
2
(50.98 x 66.73 x 30.12) x 2
+ 34.65 x 66.73 x 30.12
(50.98 x 66.73 x 30.12) x 2
+ 34.65 x 66.73 x 30.12
Shipping Dimensions (WxHxD)
mm (1,363 x 1,912 x 832) x 2 (1,363 x 1,912 x 832) x 2
(1,363 x 1,912 x 832) x 2
+ 948 x 1,912 x 832
(1,363 x 1,912 x 832) x 2
+ 948 x 1,912 x 832
inch
(53.66 x 75.28 x 32.76) x
2
(53.66 x 75.28 x 32.76) x
2
(53.66 x 75.28 x 32.76) x 2
+ 37.32 x 75.28 x 32.76
(53.66 x 75.28 x 32.76) x 2
+ 37.32 x 75.28 x 32.76
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
Model Name AM360FXVAFR/AA AM384FXVAFR/AA AM408FXVAFR/AA AM432FXVAFR/AA
Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60
Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY
Performance
Ton TON 30.00 32.00 34.00 36.00
Capacity
(Nominal)
Cooling1)
Btu/h 360,000 384,000 408,000 432,000
Heating1)
Btu/h 405,000 432,000 459,000 486,000
Capacity
(Rated)
Cooling Btu/h 345000 366000 390000 414000
Heating Btu/h 385000 412000 437000 462000
Power
MCA A 133.2 138.6 148.2 157.8
MOP A 175 170 190 210
Compressor
Type - SSC Scroll x 5 SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6
Output kW × n (4.96x2)x2 + (4.96) (4.96x2)x2 + (4.96x2) (4.96x2) + (4.96x2)x2 (4.96x2)x3
Model Name - DS-GB052FBVASG x 5 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 5500 6600 6600 6600
fl. oz. 388.86 466.63 466.63 466.63
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W (620 x 2) x 2 + 400 x 1 (620 x 2) x 3 (620 x 2) x 3 (620 x 2) x 3
Air Flow Rate CFM 9,535.32 x 2 + 7,239.78 9,182.16 x 2 + 9,535.32 9,182.16 + 9,535.32 x 2 9,535.32 x 3
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 19.05 19.05 19.05 19.05
Ø, inch 3/4 3/4 3/4 3/4
Gas Pipe
Ø, mm 41.28 41.28 41.28 41.28
Ø, inch 1 5/8 1 5/8 1 5/8 1 5/8
High Pressure Gas Pipe (for HR)
Ø, mm 34.92 34.92 34.92 34.92
Ø, inch 1 3/8 1 3/8 1 3/8 1 3/8
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 22.90 23.50 24.80 26.10
lbs 50.49 51.81 54.67 57.54
Sound2)
Sound Pressure
dB(A)
- - - -
Sound Power - - - -
External
Dimension
Net Weight
kg 293.0 x 2 + 190.0 278.0 x 2 + 293.0 278.0 + 293.0 x 2 293.0 x 3
lbs 645.95 x 2 + 418.88 612.89 x 2 + 645.95 612.89 + 645.95 x 2 645.95 x 3
Shipping Weight
kg 312.0 x 2 + 206.0 300.0 x 2 + 312.0 300.0 + 312.0 x 2 312.0 x 3
lbs 687.84 x 2 + 454.15 661.39 x 2 + 687.84 661.39 + 687.84 x 2 687.84 x 3
Net Dimensions (WxHxD)
mm
(1,295 x 1,695 x 765) x 2
+ 880 x 1,695 x 765
(1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3
inch
(50.98 x 66.73 x 30.12) x
2 + 34.65 x 66.73 x 30.12
(50.98 x 66.73 x 30.12) x
3
(50.98 x 66.73 x 30.12) x 3 (50.98 x 66.73 x 30.12) x 3
Shipping Dimensions (WxHxD)
mm
(1,363 x 1,912 x 832) x 2
+ 948 x 1,912 x 832
(1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3
inch
(53.66 x 75.28 x 32.76) x
2 + 37.32 x 75.28 x 32.76
(53.66 x 75.28 x 32.76) x
3
(53.66 x 75.28 x 32.76) x
3
(53.66 x 75.28 x 32.76) x 3
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S
7776
SPECIFICATIONS - OUTDOOR UNITS
SPECIFICATIONS
SPECIFICATIONS
DVM S HEAT PUMP (460V) DVM S HEAT PUMP (460V)
OUTDOOR UNITS
Model Name AM072FXVAJH/AA AM096FXVAJH/AA AM120FXVAJH/AA AM144FXVAJH/AA
Power Supply Ø, V, Hz 3, 460, 60 3, 460, 60 3, 460, 60 3, 460, 60
Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP
Performance
Ton TON 6.00 8.00 10.00 12.00
Capacity
(Nominal)
Cooling1)
Btu/h 72,000 92,000 120,000 144,000
Heating1)
Btu/h 81,000 108,000 135,000 162,000
Capacity
(Rated)
Cooling Btu/h 69,000 92,000 114,000 138,000
Heating Btu/h 77,000 103,000 129,000 154,000
Power
MCA A 16.4 19 21.7 26.4
MOP A 20 25 30 40
Compressor
Type - SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 2
Output kW × n (4.96) (6.13) (6.13) (4.96x2)
Model Name - DS-GB052FAVASG x 1 DS-GB066FAVASG x 1 DS-GB066FAVASG x 1 DS-GB052FAVASG x 2
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 1100 1100 1100 2200
fl. oz. 77.77 77.77 77.77 155.54
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W 400 x 1 620 x 2 620 x 2 620 x 2
Air Flow Rate CFM 7,239.78 9,182.16 9,182.16 9,535.32
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 9.52 9.52 12.70 12.70
Ø, inch 3/8 3/8 1/2 1/2
Gas Pipe
Ø, mm 19.05 22.22 28.58 28.58
Ø, inch 3/4 7/8 1 1/8 1 1/8
High Pressure Gas Pipe (for HR)
Ø, mm - - - -
Ø, inch - - - -
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 5.50 7.40 7.40 8.70
lbs 12.13 16.31 16.31 19.18
Sound2)
Sound Pressure
dB(A)
60.0 61.0 61.0 62.0
Sound Power 81 81 81 83
External
Dimension
Net Weight
kg 190.0 278.0 278.0 293.0
lbs 418.88 612.89 612.89 645.95
Shipping Weight
kg 206.0 300.0 300.0 312.0
lbs 454.15 661.39 661.39 687.84
Net Dimensions (WxHxD)
mm 880 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765
inch 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12
Shipping Dimensions (WxHxD)
mm 948 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832
inch 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
Model Name AM168FXVAJH/AA AM192FXVAJH/AA AM216FXVAJH/AA AM240FXVAJH/AA
Power Supply Ø, V, Hz 3, 460, 60 3, 460, 60 3, 460, 60 3, 460, 60
Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP
Performance
Ton TON 13.67 16.00 18.00 20.00
Capacity
(Nominal)
Cooling1)
Btu/h 164,000 192,000 216,000 240,000
Heating1)
Btu/h 189,000 216,000 243,000 270,000
Capacity
(Rated)
Cooling Btu/h 161000 183000 207000 228000
Heating Btu/h 180000 206000 231000 258000
Power
MCA A 35.4 38.1 42.8 43.4
MOP A 60 50 60 60
Compressor
Type - SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 3 SSC Scroll x 2
Output kW × n (4.96) + (6.13) (4.96) + (6.13) (4.96) + (4.96x2) (6.13)x2
Model Name -
DS-GB052FAVASG x 1 +
DS-GB066FAVASG x 1
DS-GB052FAVASG x 1 +
DS-GB066FAVASG x 1
DS-GB052FAVASG x 3 DS-GB066FAVASG x 2
Oil
Type - PVE PVE PVE PVE
Initial Charge
cc 2200 2200 3300 2200
fl. oz. 155.54 155.54 233.32 155.54
Fan
Type - Propeller Propeller Propeller Propeller
Output x n W 400 x 1 + 620 x 2 400 x 1 + 620 x 2 400 x 1 + 620 x 2 (620 x 2) x 2
Air Flow Rate CFM 7,239.78 + 9,182.16 7,239.78 + 9,182.16 7,239.78 + 9,535.32 9,182.16 x 2
External Static
Pressure
Max.
mmAq 8.00 8.00 8.00 8.00
In Wg 0.31 0.31 0.31 0.31
Piping
Connections
Liquid Pipe
Ø, mm 15.88 15.88 15.88 15.88
Ø, inch 5/8 5/8 5/8 5/8
Gas Pipe
Ø, mm 28.58 28.58 28.58 28.58
Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8
High Pressure Gas Pipe (for HR)
Ø, mm - - - -
Ø, inch - - - -
Installation
Limitation
Max. Length
m 200(220) 200(220) 200(220) 200(220)
ft 656(722) 656(722) 656(722) 656(722)
Max. Height
m 110(40) 110(40) 110(40) 110(40)
ft 361(131) 361(131) 361(131) 361(131)
Refrigerant
Type - R410A R410A R410A R410A
Factory Charging
kg 12.90 12.90 14.20 14.80
lbs 28.44 28.44 31.31 32.63
Sound2)
Sound Pressure
dB(A)
- - - -
Sound Power - - - -
External
Dimension
Net Weight
kg 190.0 + 278.0 190.0 + 278.0 190.0 + 293.0 278.0 x 2
lbs 418.88 + 612.89 418.88 + 612.89 418.88 + 645.95 612.89 x 2
Shipping Weight
kg 206.0 + 300.0 206.0 + 300.0 206.0 + 312.0 300.0 x 2
lbs 454.15 + 661.39 454.15 + 661.39 454.15 + 687.84 661.39 x 2
Net Dimensions (WxHxD)
mm
880 x 1,695 x 765 + 1,295
x 1,695 x 765
880 x 1,695 x 765 + 1,295
x 1,695 x 765
880 x 1,695 x 765 + 1,295
x 1,695 x 765
(1,295 x 1,695 x 765) x 2
inch
34.65 x 66.73 x 30.12 +
50.98 x 66.73 x 30.12
34.65 x 66.73 x 30.12 +
50.98 x 66.73 x 30.12
34.65 x 66.73 x 30.12 +
50.98 x 66.73 x 30.12
(50.98 x 66.73 x 30.12) x
2
Shipping Dimensions (WxHxD)
mm
948 x 1,912 x 832 + 1,363
x 1,912 x 832
948 x 1,912 x 832 + 1,363
x 1,912 x 832
948 x 1,912 x 832 + 1,363
x 1,912 x 832
(1,363 x 1,912 x 832) x 2
inch
37.32 x 75.28 x 32.76 +
53.66 x 75.28 x 32.76
37.32 x 75.28 x 32.76 +
53.66 x 75.28 x 32.76
37.32 x 75.28 x 32.76 +
53.66 x 75.28 x 32.76
(53.66 x 75.28 x 32.76) x
2
Operating
Temp. Range
Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0
Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0
1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft);
- Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB
- Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB
2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
3) Specifications are subject to change without prior notice for product improvement.
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]
Samsung dvm s catalogue [60 hz.]

More Related Content

What's hot

Pressure Relief valve sizing and design
Pressure Relief valve sizing and designPressure Relief valve sizing and design
Pressure Relief valve sizing and design
Héctor Nguema Ondo
 
Safety valve in process industry1
Safety valve in process industry1Safety valve in process industry1
Safety valve in process industry1
Nitesh Chauhan
 
psv specifications
psv specificationspsv specifications
psv specifications
Kumar Natarajan
 
Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system
Srinath Menon
 
Basic refrigeration cycle
Basic refrigeration  cycleBasic refrigeration  cycle
Basic refrigeration cycle
Nina Maulani
 
RESNET: HVAC Presentation
RESNET: HVAC PresentationRESNET: HVAC Presentation
VRF system presentation !
VRF system presentation !VRF system presentation !
VRF system presentation !
Mohamed Sharbudeen Ayub
 
Hvac systems presentation_slides
Hvac systems presentation_slidesHvac systems presentation_slides
Hvac systems presentation_slides
guy ygal
 
Air Cooled Heat Exchanger Design
Air Cooled Heat Exchanger DesignAir Cooled Heat Exchanger Design
Air Cooled Heat Exchanger Design
Gerard B. Hawkins
 
Hvac - presentation (Air conditioning presentation)
Hvac - presentation (Air conditioning presentation) Hvac - presentation (Air conditioning presentation)
Hvac - presentation (Air conditioning presentation)
SYED KHURSHID ALAM ARZOO
 
Cooling tower
Cooling towerCooling tower
Cooling tower
AjeetSaini3
 
Design Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage TanksDesign Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Kushagra Saxena
 
Energy recovery presentation
Energy recovery presentationEnergy recovery presentation
Energy recovery presentationplugtrab
 
Blue star package units
Blue star package unitsBlue star package units
Blue star package units
Kumar Ramaiah
 
Heat exchanger design
Heat exchanger designHeat exchanger design
Heat exchanger design
adnanali309
 
Refrigeration and air conditioning
Refrigeration and air conditioningRefrigeration and air conditioning
Refrigeration and air conditioningEr Santhosh
 
An ejector refrigeration cycle
An ejector refrigeration cycleAn ejector refrigeration cycle
An ejector refrigeration cycle
xueyuejingling
 
Coal fired electric power plants23
Coal fired electric power plants23Coal fired electric power plants23
Coal fired electric power plants23Munna Sagar
 
Basic refrigeration cycle .
Basic refrigeration cycle .Basic refrigeration cycle .
Basic refrigeration cycle .
JISHNU U
 

What's hot (20)

Pressure Relief valve sizing and design
Pressure Relief valve sizing and designPressure Relief valve sizing and design
Pressure Relief valve sizing and design
 
Safety valve in process industry1
Safety valve in process industry1Safety valve in process industry1
Safety valve in process industry1
 
psv specifications
psv specificationspsv specifications
psv specifications
 
Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system Overview and Maintenanaces of HVAC system
Overview and Maintenanaces of HVAC system
 
Basic refrigeration cycle
Basic refrigeration  cycleBasic refrigeration  cycle
Basic refrigeration cycle
 
RESNET: HVAC Presentation
RESNET: HVAC PresentationRESNET: HVAC Presentation
RESNET: HVAC Presentation
 
VRF system presentation !
VRF system presentation !VRF system presentation !
VRF system presentation !
 
Hvac systems presentation_slides
Hvac systems presentation_slidesHvac systems presentation_slides
Hvac systems presentation_slides
 
Air Cooled Heat Exchanger Design
Air Cooled Heat Exchanger DesignAir Cooled Heat Exchanger Design
Air Cooled Heat Exchanger Design
 
Hvac - presentation (Air conditioning presentation)
Hvac - presentation (Air conditioning presentation) Hvac - presentation (Air conditioning presentation)
Hvac - presentation (Air conditioning presentation)
 
Cooling tower
Cooling towerCooling tower
Cooling tower
 
Design Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage TanksDesign Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
Design Calculation of Venting for Atmospheric & Low Pressure Storage Tanks
 
Energy recovery presentation
Energy recovery presentationEnergy recovery presentation
Energy recovery presentation
 
Blue star package units
Blue star package unitsBlue star package units
Blue star package units
 
Heat exchanger design
Heat exchanger designHeat exchanger design
Heat exchanger design
 
DAIKIN
DAIKINDAIKIN
DAIKIN
 
Refrigeration and air conditioning
Refrigeration and air conditioningRefrigeration and air conditioning
Refrigeration and air conditioning
 
An ejector refrigeration cycle
An ejector refrigeration cycleAn ejector refrigeration cycle
An ejector refrigeration cycle
 
Coal fired electric power plants23
Coal fired electric power plants23Coal fired electric power plants23
Coal fired electric power plants23
 
Basic refrigeration cycle .
Basic refrigeration cycle .Basic refrigeration cycle .
Basic refrigeration cycle .
 

Viewers also liked

Samsung 2012 vrf [plus iv] catalog
Samsung 2012 vrf [plus iv] catalogSamsung 2012 vrf [plus iv] catalog
Samsung 2012 vrf [plus iv] catalog
Haluk TOSUN
 
Refrigerant Flow Zone Heating and Cooling System Catalog
Refrigerant Flow Zone Heating and Cooling System CatalogRefrigerant Flow Zone Heating and Cooling System Catalog
Refrigerant Flow Zone Heating and Cooling System Catalog
UniqueIndoorComfortLibertyville
 
Samsung cac salesguide_eng
Samsung cac salesguide_engSamsung cac salesguide_eng
Samsung cac salesguide_eng
Haluk TOSUN
 
Презентація можливостей навчання членів виборчих комісій
Презентація можливостей навчання членів виборчих комісійПрезентація можливостей навчання членів виборчих комісій
Презентація можливостей навчання членів виборчих комісійVolyn Media
 
Samsung sac category catalogue cac tr
Samsung sac category catalogue cac trSamsung sac category catalogue cac tr
Samsung sac category catalogue cac tr
Haluk TOSUN
 
Samsung sac category catalogue multi fjm tr
Samsung sac category catalogue multi fjm trSamsung sac category catalogue multi fjm tr
Samsung sac category catalogue multi fjm tr
Haluk TOSUN
 
Boreas Boya
Boreas Boya Boreas Boya
Boreas Boya
Haluk TOSUN
 
Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0
Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0
Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0
Haluk TOSUN
 
[Tdb] vrf 360 cst for tk ver 1.0
[Tdb] vrf 360 cst for tk ver 1.0[Tdb] vrf 360 cst for tk ver 1.0
[Tdb] vrf 360 cst for tk ver 1.0
Haluk TOSUN
 
Samsung 2009 cac catalog
Samsung 2009 cac catalogSamsung 2009 cac catalog
Samsung 2009 cac catalog
Haluk TOSUN
 
Boreas AHU [RU]
Boreas AHU [RU]Boreas AHU [RU]
Boreas AHU [RU]
Haluk TOSUN
 
Презентация компании ADE Project.
Презентация компании ADE Project.Презентация компании ADE Project.
Презентация компании ADE Project.
Alexander Vasilyev
 
Boreas AHU [EN]
Boreas AHU [EN]Boreas AHU [EN]
Boreas AHU [EN]
Haluk TOSUN
 
Boreas AHU [TR]
Boreas AHU [TR]Boreas AHU [TR]
Boreas AHU [TR]
Haluk TOSUN
 
Voltas Air-Conditioners- Service Management
Voltas Air-Conditioners- Service ManagementVoltas Air-Conditioners- Service Management
Voltas Air-Conditioners- Service Management
Kirk Coutinho
 
Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1
Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1
Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1
Haluk TOSUN
 
Samsung sac global reference catalogue
Samsung sac global reference catalogueSamsung sac global reference catalogue
Samsung sac global reference catalogue
Haluk TOSUN
 
GADGET STUDIO sponsorship presentation
GADGET STUDIO sponsorship presentationGADGET STUDIO sponsorship presentation
GADGET STUDIO sponsorship presentation
Nickolay Turubar
 

Viewers also liked (20)

Samsung 2012 vrf [plus iv] catalog
Samsung 2012 vrf [plus iv] catalogSamsung 2012 vrf [plus iv] catalog
Samsung 2012 vrf [plus iv] catalog
 
Refrigerant Flow Zone Heating and Cooling System Catalog
Refrigerant Flow Zone Heating and Cooling System CatalogRefrigerant Flow Zone Heating and Cooling System Catalog
Refrigerant Flow Zone Heating and Cooling System Catalog
 
Samsung cac salesguide_eng
Samsung cac salesguide_engSamsung cac salesguide_eng
Samsung cac salesguide_eng
 
Презентація можливостей навчання членів виборчих комісій
Презентація можливостей навчання членів виборчих комісійПрезентація можливостей навчання членів виборчих комісій
Презентація можливостей навчання членів виборчих комісій
 
Samsung sac category catalogue cac tr
Samsung sac category catalogue cac trSamsung sac category catalogue cac tr
Samsung sac category catalogue cac tr
 
Samsung sac category catalogue multi fjm tr
Samsung sac category catalogue multi fjm trSamsung sac category catalogue multi fjm tr
Samsung sac category catalogue multi fjm tr
 
Boreas Boya
Boreas Boya Boreas Boya
Boreas Boya
 
Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0
Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0
Tdb vrf dvm s standard for turkey (odu 50 hz hp) ver.1.0
 
[Tdb] vrf 360 cst for tk ver 1.0
[Tdb] vrf 360 cst for tk ver 1.0[Tdb] vrf 360 cst for tk ver 1.0
[Tdb] vrf 360 cst for tk ver 1.0
 
Samsung 2009 cac catalog
Samsung 2009 cac catalogSamsung 2009 cac catalog
Samsung 2009 cac catalog
 
BBC_project_2017
BBC_project_2017BBC_project_2017
BBC_project_2017
 
Boreas AHU [RU]
Boreas AHU [RU]Boreas AHU [RU]
Boreas AHU [RU]
 
Презентация компании ADE Project.
Презентация компании ADE Project.Презентация компании ADE Project.
Презентация компании ADE Project.
 
Boreas AHU [EN]
Boreas AHU [EN]Boreas AHU [EN]
Boreas AHU [EN]
 
Boreas AHU [TR]
Boreas AHU [TR]Boreas AHU [TR]
Boreas AHU [TR]
 
Voltas ac
Voltas acVoltas ac
Voltas ac
 
Voltas Air-Conditioners- Service Management
Voltas Air-Conditioners- Service ManagementVoltas Air-Conditioners- Service Management
Voltas Air-Conditioners- Service Management
 
Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1
Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1
Samsung tdb-dvm-s-water e-outdoor_dbeu-13082_da1
 
Samsung sac global reference catalogue
Samsung sac global reference catalogueSamsung sac global reference catalogue
Samsung sac global reference catalogue
 
GADGET STUDIO sponsorship presentation
GADGET STUDIO sponsorship presentationGADGET STUDIO sponsorship presentation
GADGET STUDIO sponsorship presentation
 

Similar to Samsung dvm s catalogue [60 hz.]

Dvm s full catalog
Dvm s full catalogDvm s full catalog
Dvm s full catalog
Haluk TOSUN
 
Sac usp-catalog-ver.1
Sac usp-catalog-ver.1Sac usp-catalog-ver.1
Sac usp-catalog-ver.1
Haluk TOSUN
 
HISENSE_VRF_product_catalogue_2019.pdf
HISENSE_VRF_product_catalogue_2019.pdfHISENSE_VRF_product_catalogue_2019.pdf
HISENSE_VRF_product_catalogue_2019.pdf
RaulN5
 
Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)
Henry Hollands
 
Toshiba
ToshibaToshiba
Toshiba
Edward Read
 
High Efficiency Solutions EEV & Monitoring Systems
High Efficiency Solutions  EEV & Monitoring SystemsHigh Efficiency Solutions  EEV & Monitoring Systems
High Efficiency Solutions EEV & Monitoring Systems
CAREL Industries S.p.A
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Beeteco
 
Dns Smartcool Eco3
Dns Smartcool Eco3Dns Smartcool Eco3
Dns Smartcool Eco3sdas61
 
10 years of Scroll Digital
10 years of Scroll Digital10 years of Scroll Digital
10 years of Scroll Digital
Abhinav Barnwal
 
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
Juma Yousef J. Saleh جمعة يوسف جمعة صالح
 
Public CNG Stations
Public CNG StationsPublic CNG Stations
Public CNG Stations
Mark Reynolds
 
Syntec Company Profile
Syntec Company ProfileSyntec Company Profile
Syntec Company ProfileAJAY MANGLA
 
Compact CNG Presentation
Compact CNG PresentationCompact CNG Presentation
Ghasem zolfaghari fyp
Ghasem zolfaghari fypGhasem zolfaghari fyp
Ghasem zolfaghari fyp
Ghasem Zolfaghari
 
Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide
UniqueIndoorComfortLibertyville
 
Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide
UniqueIndoorComfortLibertyville
 
Điều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTUĐiều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTU
Myravn1
 
Webasto marine catalog 2016
Webasto marine catalog 2016Webasto marine catalog 2016
Webasto marine catalog 2016
Gabriele Brivio
 
Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1
Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1
Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1
Copywriter Collective
 

Similar to Samsung dvm s catalogue [60 hz.] (20)

Dvm s full catalog
Dvm s full catalogDvm s full catalog
Dvm s full catalog
 
Sac usp-catalog-ver.1
Sac usp-catalog-ver.1Sac usp-catalog-ver.1
Sac usp-catalog-ver.1
 
HISENSE_VRF_product_catalogue_2019.pdf
HISENSE_VRF_product_catalogue_2019.pdfHISENSE_VRF_product_catalogue_2019.pdf
HISENSE_VRF_product_catalogue_2019.pdf
 
Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)
 
Toshiba
ToshibaToshiba
Toshiba
 
Products & services (new)
Products & services (new)Products & services (new)
Products & services (new)
 
High Efficiency Solutions EEV & Monitoring Systems
High Efficiency Solutions  EEV & Monitoring SystemsHigh Efficiency Solutions  EEV & Monitoring Systems
High Efficiency Solutions EEV & Monitoring Systems
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)
 
Dns Smartcool Eco3
Dns Smartcool Eco3Dns Smartcool Eco3
Dns Smartcool Eco3
 
10 years of Scroll Digital
10 years of Scroll Digital10 years of Scroll Digital
10 years of Scroll Digital
 
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
 
Public CNG Stations
Public CNG StationsPublic CNG Stations
Public CNG Stations
 
Syntec Company Profile
Syntec Company ProfileSyntec Company Profile
Syntec Company Profile
 
Compact CNG Presentation
Compact CNG PresentationCompact CNG Presentation
Compact CNG Presentation
 
Ghasem zolfaghari fyp
Ghasem zolfaghari fypGhasem zolfaghari fyp
Ghasem zolfaghari fyp
 
Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide
 
Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide Unico Residential HVAC System Installation Guide
Unico Residential HVAC System Installation Guide
 
Điều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTUĐiều hòa âm trần LG 36000BTU
Điều hòa âm trần LG 36000BTU
 
Webasto marine catalog 2016
Webasto marine catalog 2016Webasto marine catalog 2016
Webasto marine catalog 2016
 
Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1
Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1
Copywriter Collective - Denzil - Dm compressors 12p_brochure_2014_0522-1
 

More from Haluk TOSUN

Rbm brass katalog
Rbm brass katalogRbm brass katalog
Rbm brass katalog
Haluk TOSUN
 
The world's largest 250 construction companies - powerPoint
The world's largest 250 construction companies - powerPointThe world's largest 250 construction companies - powerPoint
The world's largest 250 construction companies - powerPoint
Haluk TOSUN
 
Samsung ehs catalogue
Samsung ehs catalogueSamsung ehs catalogue
Samsung ehs catalogue
Haluk TOSUN
 
samsung vrf dvm s 2013 sac catalouge
samsung vrf dvm s 2013 sac catalougesamsung vrf dvm s 2013 sac catalouge
samsung vrf dvm s 2013 sac catalouge
Haluk TOSUN
 
Samsung Twin rotary compressor R-410A / R-22
Samsung Twin rotary compressor R-410A / R-22Samsung Twin rotary compressor R-410A / R-22
Samsung Twin rotary compressor R-410A / R-22
Haluk TOSUN
 
Samsung 2009 dvm [plus III] catalogue
Samsung 2009 dvm [plus III] catalogueSamsung 2009 dvm [plus III] catalogue
Samsung 2009 dvm [plus III] catalogue
Haluk TOSUN
 
Samsun fjm salesguide_eng
Samsun fjm salesguide_engSamsun fjm salesguide_eng
Samsun fjm salesguide_eng
Haluk TOSUN
 
Boreas test
Boreas testBoreas test
Boreas test
Haluk TOSUN
 
Boreas paketleme
Boreas paketlemeBoreas paketleme
Boreas paketleme
Haluk TOSUN
 
Boreas boya
Boreas boya Boreas boya
Boreas boya
Haluk TOSUN
 
Boreas klima santral
Boreas klima santralBoreas klima santral
Boreas klima santral
Haluk TOSUN
 
Boreas test
Boreas testBoreas test
Boreas test
Haluk TOSUN
 
Eurovent sınıfları yurtiçi
Eurovent sınıfları yurtiçiEurovent sınıfları yurtiçi
Eurovent sınıfları yurtiçi
Haluk TOSUN
 
Eurovent sınıfları yurtdısı
Eurovent sınıfları yurtdısıEurovent sınıfları yurtdısı
Eurovent sınıfları yurtdısı
Haluk TOSUN
 

More from Haluk TOSUN (14)

Rbm brass katalog
Rbm brass katalogRbm brass katalog
Rbm brass katalog
 
The world's largest 250 construction companies - powerPoint
The world's largest 250 construction companies - powerPointThe world's largest 250 construction companies - powerPoint
The world's largest 250 construction companies - powerPoint
 
Samsung ehs catalogue
Samsung ehs catalogueSamsung ehs catalogue
Samsung ehs catalogue
 
samsung vrf dvm s 2013 sac catalouge
samsung vrf dvm s 2013 sac catalougesamsung vrf dvm s 2013 sac catalouge
samsung vrf dvm s 2013 sac catalouge
 
Samsung Twin rotary compressor R-410A / R-22
Samsung Twin rotary compressor R-410A / R-22Samsung Twin rotary compressor R-410A / R-22
Samsung Twin rotary compressor R-410A / R-22
 
Samsung 2009 dvm [plus III] catalogue
Samsung 2009 dvm [plus III] catalogueSamsung 2009 dvm [plus III] catalogue
Samsung 2009 dvm [plus III] catalogue
 
Samsun fjm salesguide_eng
Samsun fjm salesguide_engSamsun fjm salesguide_eng
Samsun fjm salesguide_eng
 
Boreas test
Boreas testBoreas test
Boreas test
 
Boreas paketleme
Boreas paketlemeBoreas paketleme
Boreas paketleme
 
Boreas boya
Boreas boya Boreas boya
Boreas boya
 
Boreas klima santral
Boreas klima santralBoreas klima santral
Boreas klima santral
 
Boreas test
Boreas testBoreas test
Boreas test
 
Eurovent sınıfları yurtiçi
Eurovent sınıfları yurtiçiEurovent sınıfları yurtiçi
Eurovent sınıfları yurtiçi
 
Eurovent sınıfları yurtdısı
Eurovent sınıfları yurtdısıEurovent sınıfları yurtdısı
Eurovent sınıfları yurtdısı
 

Recently uploaded

Design and Analysis of Algorithms-DP,Backtracking,Graphs,B&B
Design and Analysis of Algorithms-DP,Backtracking,Graphs,B&BDesign and Analysis of Algorithms-DP,Backtracking,Graphs,B&B
Design and Analysis of Algorithms-DP,Backtracking,Graphs,B&B
Sreedhar Chowdam
 
block diagram and signal flow graph representation
block diagram and signal flow graph representationblock diagram and signal flow graph representation
block diagram and signal flow graph representation
Divya Somashekar
 
Runway Orientation Based on the Wind Rose Diagram.pptx
Runway Orientation Based on the Wind Rose Diagram.pptxRunway Orientation Based on the Wind Rose Diagram.pptx
Runway Orientation Based on the Wind Rose Diagram.pptx
SupreethSP4
 
J.Yang, ICLR 2024, MLILAB, KAIST AI.pdf
J.Yang,  ICLR 2024, MLILAB, KAIST AI.pdfJ.Yang,  ICLR 2024, MLILAB, KAIST AI.pdf
J.Yang, ICLR 2024, MLILAB, KAIST AI.pdf
MLILAB
 
ethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.pptethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.ppt
Jayaprasanna4
 
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
ydteq
 
Water Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdfWater Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation & Control
 
Top 10 Oil and Gas Projects in Saudi Arabia 2024.pdf
Top 10 Oil and Gas Projects in Saudi Arabia 2024.pdfTop 10 Oil and Gas Projects in Saudi Arabia 2024.pdf
Top 10 Oil and Gas Projects in Saudi Arabia 2024.pdf
Teleport Manpower Consultant
 
English lab ppt no titlespecENG PPTt.pdf
English lab ppt no titlespecENG PPTt.pdfEnglish lab ppt no titlespecENG PPTt.pdf
English lab ppt no titlespecENG PPTt.pdf
BrazilAccount1
 
Investor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptxInvestor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptx
AmarGB2
 
DESIGN A COTTON SEED SEPARATION MACHINE.docx
DESIGN A COTTON SEED SEPARATION MACHINE.docxDESIGN A COTTON SEED SEPARATION MACHINE.docx
DESIGN A COTTON SEED SEPARATION MACHINE.docx
FluxPrime1
 
HYDROPOWER - Hydroelectric power generation
HYDROPOWER - Hydroelectric power generationHYDROPOWER - Hydroelectric power generation
HYDROPOWER - Hydroelectric power generation
Robbie Edward Sayers
 
Hierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power SystemHierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power System
Kerry Sado
 
Architectural Portfolio Sean Lockwood
Architectural Portfolio Sean LockwoodArchitectural Portfolio Sean Lockwood
Architectural Portfolio Sean Lockwood
seandesed
 
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdfAKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
SamSarthak3
 
space technology lecture notes on satellite
space technology lecture notes on satellitespace technology lecture notes on satellite
space technology lecture notes on satellite
ongomchris
 
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
AJAYKUMARPUND1
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
Amil Baba Dawood bangali
 
H.Seo, ICLR 2024, MLILAB, KAIST AI.pdf
H.Seo,  ICLR 2024, MLILAB,  KAIST AI.pdfH.Seo,  ICLR 2024, MLILAB,  KAIST AI.pdf
H.Seo, ICLR 2024, MLILAB, KAIST AI.pdf
MLILAB
 
The role of big data in decision making.
The role of big data in decision making.The role of big data in decision making.
The role of big data in decision making.
ankuprajapati0525
 

Recently uploaded (20)

Design and Analysis of Algorithms-DP,Backtracking,Graphs,B&B
Design and Analysis of Algorithms-DP,Backtracking,Graphs,B&BDesign and Analysis of Algorithms-DP,Backtracking,Graphs,B&B
Design and Analysis of Algorithms-DP,Backtracking,Graphs,B&B
 
block diagram and signal flow graph representation
block diagram and signal flow graph representationblock diagram and signal flow graph representation
block diagram and signal flow graph representation
 
Runway Orientation Based on the Wind Rose Diagram.pptx
Runway Orientation Based on the Wind Rose Diagram.pptxRunway Orientation Based on the Wind Rose Diagram.pptx
Runway Orientation Based on the Wind Rose Diagram.pptx
 
J.Yang, ICLR 2024, MLILAB, KAIST AI.pdf
J.Yang,  ICLR 2024, MLILAB, KAIST AI.pdfJ.Yang,  ICLR 2024, MLILAB, KAIST AI.pdf
J.Yang, ICLR 2024, MLILAB, KAIST AI.pdf
 
ethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.pptethical hacking in wireless-hacking1.ppt
ethical hacking in wireless-hacking1.ppt
 
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
一比一原版(UofT毕业证)多伦多大学毕业证成绩单如何办理
 
Water Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdfWater Industry Process Automation and Control Monthly - May 2024.pdf
Water Industry Process Automation and Control Monthly - May 2024.pdf
 
Top 10 Oil and Gas Projects in Saudi Arabia 2024.pdf
Top 10 Oil and Gas Projects in Saudi Arabia 2024.pdfTop 10 Oil and Gas Projects in Saudi Arabia 2024.pdf
Top 10 Oil and Gas Projects in Saudi Arabia 2024.pdf
 
English lab ppt no titlespecENG PPTt.pdf
English lab ppt no titlespecENG PPTt.pdfEnglish lab ppt no titlespecENG PPTt.pdf
English lab ppt no titlespecENG PPTt.pdf
 
Investor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptxInvestor-Presentation-Q1FY2024 investor presentation document.pptx
Investor-Presentation-Q1FY2024 investor presentation document.pptx
 
DESIGN A COTTON SEED SEPARATION MACHINE.docx
DESIGN A COTTON SEED SEPARATION MACHINE.docxDESIGN A COTTON SEED SEPARATION MACHINE.docx
DESIGN A COTTON SEED SEPARATION MACHINE.docx
 
HYDROPOWER - Hydroelectric power generation
HYDROPOWER - Hydroelectric power generationHYDROPOWER - Hydroelectric power generation
HYDROPOWER - Hydroelectric power generation
 
Hierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power SystemHierarchical Digital Twin of a Naval Power System
Hierarchical Digital Twin of a Naval Power System
 
Architectural Portfolio Sean Lockwood
Architectural Portfolio Sean LockwoodArchitectural Portfolio Sean Lockwood
Architectural Portfolio Sean Lockwood
 
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdfAKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
AKS UNIVERSITY Satna Final Year Project By OM Hardaha.pdf
 
space technology lecture notes on satellite
space technology lecture notes on satellitespace technology lecture notes on satellite
space technology lecture notes on satellite
 
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
Pile Foundation by Venkatesh Taduvai (Sub Geotechnical Engineering II)-conver...
 
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...
 
H.Seo, ICLR 2024, MLILAB, KAIST AI.pdf
H.Seo,  ICLR 2024, MLILAB,  KAIST AI.pdfH.Seo,  ICLR 2024, MLILAB,  KAIST AI.pdf
H.Seo, ICLR 2024, MLILAB, KAIST AI.pdf
 
The role of big data in decision making.
The role of big data in decision making.The role of big data in decision making.
The role of big data in decision making.
 

Samsung dvm s catalogue [60 hz.]

  • 1. PRODUCT CATALOG SAMSUNG VRF SYSTEM HIGH EFFICIENCY SYSTEM AIR CONDITIONER Carlisle 6 Pine Hill Drive Carlisle, PA 17013 866-243-6498 Fort Worth 3001 Northern Cross Blvd. #361 Fort Worth, TX 76137 817-838-6066 Los Angeles 8750 Pioneer Blvd. Santa Fe Springs, CA 90670 888-699-6067 New Jersey 411 Hackensack Av. Hackensack NJ 07601 www.samsungdvm-s.comVersion 1-4.13
  • 2. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 3 - Chief Marketing Officer, SAMSUNG “Put simply, our differentiation is centered on producing innovative technology that brings genuine change to people’s lives. We do this by bringing a relentless focus on consumer experience and product innovation in everything we do.” Best Global Brand Rankings ($Value rounded off to nearest billion) $18Billion $18Billion Rank-21st 2008 2009 Rank-19th 2010 Rank-19th $19Billion Rank-17th 2011 $23Billion Rank-9th 2012 $32Billion ECO-FRIENDLY SAMSUNG Preserving for future generations Thinking of people and the environment, Samsung has been developing products/solutions that are eco-friendly without sacrificing performance. Realizing the hopes for a greener, healthier life for people and the generations that follow, Samsung’s environment-friendly technologies work to make the world a safer and more liveable place. Eco-Friendy Air Conditioners by Samsung Making continuous efforts to stay eco-friendly, Samsung air conditioners use R-410A, an environment-friendly refrigerant to help rid the air of pollutants and restrain the use of materials with high global warming potential (GWP). These energy-efficient air conditioners not only save you money, but help conserve the environment. 2 MOVING FORWARD WITH OUR CUSTOMERS SAMSUNG’S DVM SYSTEMS ARE A GLOBAL OPERATION Various groups from all over the world choose Samsung’s DVM systems for their proven performance. Project Location Project LOCATION: U.A.E PROJECT: RESIDENTIAL BUILDING LOCATION: CHINA - PROJECT: INTERNATIONAL AIRPORT LOCATION: VIETNAM PROJECT: HOTEL LOCATION: B.C., CANADA PROJECT: DOUGLAS COLLEGE LOCATION: TURKEY PROJECT: PRINCESS RESORT LOCATION: KOREA PROJECT: SOCCER STADIUM LOCATION: TEXAS, USA PROJECT: HMS LOCATION: HUNGARY - PROJECT: SHOPPING CENTER (see details above) LOCATION: TENNESSEE, USA - PROJECT: LIPSCOMB COLLEGE Hungary’s most beautiful shopping center, the Váci 1 was recently outfitted with Samsung’s DVM system. This was a very ambitious project, not only because the building is over 129,000 sq.ft., but also because it has been a UNESCO WORLD HERITAGE site since 1933. Due to this, extreme care and dedication went into preserving the building’s infrastructure and interior designs. When needed, Samsung engineers were able to delicately install and hide indoor units behind sofas and walls, to avoid disrupting the original interior architecture. 13 systems were able to act as 1, with features such as DMS, giving engineers total access and the ability to monitor and adjust the system over the internet or ethernet. All in all, the project was ahuge success for all parties involved. PROJECT DETAILS* Location: Váci 1 Shopping Center in Budapest, Hungary Equipment: 60 indoor units in common areas 252 indoor units installed in 72 shops 52 outdoor units 13 total systems acting as 1 Building: 130,000 sq. ft. 7 total floors (2 underground, 5 above ground) 100 yrs old Marble walls and floors UNESCO WORLD HERITAGE site *You can view the complete video of this project in the media section at www.samsungdvm-s.com LOCATION: QATAR PROJECT: OFFICE BUILDING
  • 3. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 54 Location Project Location_Croatia Project_ Project_ Location_ Project_ CAPACITY TABLES noT21noT01noT8noT6eziS 6 Ton 1noT8 1 1 1 1 1 1 1 1 10 Ton 1 12 Ton 1 noT41 noT61 18 Ton 20 Ton 2 22 Ton 11 24 Ton 2 111noT62 111noT82 30 Ton 2 32 Ton 12 34 Ton 21 36 Ton 3 SingleC/UDoubleC/UTripleC/U AM144FXVAJR/AA AM144FXVAFR/AA AM144FXVAJH/AA AM144FXVAJR/AA AM120FXVAFH/AA AM120FXVAFR/AA AM120FXVAJH/AA AM120FXVAJR/AA AM096FXVAFH/AA AM096FXVAFR/AA AM096FXVAJH/AA AM096FXVAJR/AA AM072FXVAFH/AA AM072FXVAFR/AA AM072FXVAJH/AA AM072FXVAJR/AA AM053FXMDCH/AAAM048FXMDCH/AAAM036FXMDCH/AA 12 Ton10 Ton6 Ton5 Ton4 Ton3 Ton HP (208/230V-1Ph) HP (208/230V-3Ph) HR (208/230V-3Ph) HP (460V-3Ph) HR (460V-3Ph) HP - Heat Pump / HR - Heat Recovery OUTDOOR UNITS 3-5 Ton 6 Ton 8-12 Ton 4 Way Cassette Mini 4 Way Cassette 1 Way Cassette H.S.P. Duct M.S.P. Duct Slim Duct Wall Mount Ceiling/Floor Mount 7,500 BTU 9,500 BTU 12,000 BTU INDOOR UNITS 18,000 BTU 20,000 BTU 24,000 BTU 30,000 BTU 36,000 BTU 48,000 BTU 76,000 BTU 96,000 BTU 8 Ton TABLE OF CONTENTS P6 - P21 OUTDOOR UNITS P22 - P47 INDOOR UNITS P66 DVM PRO P68 - P97 SPECIFICATIONS P48 - P65 INDOOR UNITS
  • 4. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 76 OUTDOORUNITS OUTDOORUNITS INNOVATIVE TECHNOLOGY Samsung’s new 3rd generation technology adopts dual inverter compressors and an upgraded vapor injection system which surpasses the performance of previous versions of the system. This optimizes energy efficiency, providing energy savings. • 3rd Generation Technology The innovative Dual Smart Inverter feature has both compressors operate simultaneously, providing balanced oil distribution, quick cooling & heating and better energy efficiency. Upgraded vapor injection system within the compressor increases the refrigerant flow rate by 20% compared to conventional products. • 3rd Generation Vapor Injection System • Dual Smart Inverter 1st generation (Variable + Fixed Units) 2nd generation (Variable + Fixed Compressors) 3rd generation (Variable + Variable Compressors) + Inverter AInverter A Inverter B Dual Smart Inverter Refrigerant Vapor Injection DVM S is a highly innovative system that adopts the new 3rd generation SSC (Samsung Scroll Compressor) technology. With its Dual Smart Inverter, DVM S provides the world, top class energy efficiency and the most powerful cooling and heating performance.This is the perfect air conditioning system that satisfies all types of environments, including large buildings. • Innovative Technology • High Efficiency • Smart Management • Flexible Installation • Comfortable & Reliable Operation • Heat Recovery As High as IEER 27 / SCHE 30
  • 5. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 98 OUTDOORUNITS OUTDOORUNITS • Dual Smart Inverter System This 3rd generation feature adopts a dual inverter compressor that upgrades refrigerant flow and the motor’s operating performance. The Dual Smart Inverter System achieves unsurpassed energy efficiency. DSI (Dual Smart Inverter) System • Dual Smart Inverter : SSC + SSC • 3rd Generation Vapor Injection • Wider operation range of BLDC motor (20-140Hz) Low-pressure refrigerant suction High-pressure refrigerant discharge With compressor speed acceleration and simultaneous starting, DVM S provides quick cooling and heating performance. • Quick Cooling & Heating Conventional DVM S DVM S CONVENTIONAL CONVENTIONAL 33% higher heating Fast Heating PerformanceFast Frequency AccelerationQuick Start (Simultaneous Operation) DVM S 9 min 10 min 7 min 0 20 40 60 80 100 Hz 0 20 40 60 80 100 Hz ON 90 sec5 sec ON Air Cooling Method Low Efficiency ConventionalDVM S Refrigerant Cooling MethodThe PCB is cooled by the refrigerant, ensuring better stability. • Refrigerant PCB Cooling System ConventionalDVM S start INVINVINVINVINV after extended operationstart after extended operation FIXED FIXEDINV Conventional (Inverter + Fixed) (Inverter + Inverter) Case 3Case 2Case 1 OFFON ON ON ON ON ON ON ON OFF OFF OFF INV FIXED Thanks to capacity control, the DSI (Dual Smart Inverter) system responds to subtle indoor load changes, saving energy. In a conventional system composed of inverter and fixed compressors, one compressor operates longer than the other which results in one compressor wearing down faster. This in fact decreases compressor durability and life span. However, with the DVM S Dual Smart Inverter System, each compressor operates in unison with the other so the overall durability and life span of the compressors increases. • Enhanced Compressor Durability With large oil storage and low OCR, DVM S can ensure reliability even in high altitude applications that require long piping. • Large Oil Storage Capacity DVM SCompany CCompany BCompany A Operation level Initial level 44oz 30oz27oz 17oz Oil storage amount 70% reduced 5.71 5.58 1.8 1.43 0.82 3.95 60 80 100 RPS OCR% OCR (Oil Circulation Ratio) amount DVM S ensures stable and equal oil balancing without requiring an extra oil balancing pipe. • Auto Oil Balancing ConventionalDVM S BalanceBalance • Fixed + Inverter Compressor • Oil unbalanced (Balance Pipe is necessary) • Inverter + Inverter Compressor • No oil balance pipe INV INV INV INV INV INV FIXEDINV FIXEDINV 3 r d G e n e r a t i o n V a p o r I n j e c t i o n
  • 6. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 1110 HIGH EFFICIENCY DVM S has achieved top class energy efficiency by adopting a dual inverter compressor with vapor injection system. Simultaneous heating/cooling efficiency: as high as 27 IEER, 30 SCHE. • Top Class Energy Efficiency OUTDOORUNITS OUTDOORUNITS 35 30 25 20 15 10 5 0 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Samsung Company D 27.9 27.1 26.06 25.88 24.75 25.52 26.64 24.39 24.08 23.97 23.26 24.45 23.74 23.04 18 15.4 15.3 16 16.2 15.5 15 14.8 15.9 15.8 15.4 14.9 SCHE comparison 30 29.6 28 26 24 22 20 18 16 14 12 10 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 IEER comparison Samsung Company D 23 27 24.2 22.7 21.9 20.7 19.6 20.2 19.2 18.1 18.6 17.7 16.9 17.1 16.3 15.5 21.5 18.8 17.2 17.6 20.2 19.1 19 16.1 19.1 18.8 17 16.1 15.3 SCHEIEER • Plate Heat Exchanger The Plate Heat Exchanger type intercooler that Samsung’s DVM S adopts improves cooling and heating efficiency. Heat efficiency with PHE has been improved by about 30% compared to conventional products with the Shell & Tube type intercooler and by 50% compared to competitors’ products with the Double Tube type intercooler. EER Heat Exchanger Performance 150% 115% 100% Double Tube Shell & Tube PHE Intercooler • Adaptive Sine Wave Control Adaptive Sine Wave Control can reduce THP (Total Harmonic Distortion). [Hz] [A] [Hz] [A] Conventional square wave controller New Sine Wave Controller • Assymetric Scroll Design With an improved fluid dynamic design, DVM S minimizes compression loss during the compression of . DVM S Conventional 1 2 Loss 2 1 * Suction from two different sides and discharge through one can cause collision of refrigerant gas which results in friction loss in the compressor. * No friction loss in the compressor, thanks to sequential suction and discharge . Loss 1 Suc. Discharge 1 2 Suc. Suc.
  • 7. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 1312 SMART MANAGEMENT DVM S has a smart management system that facilitates self-diagnosis, auto commissioning, auto management and mobile data transmission. Management is easy and convenient with the ability to control the system with your smart phone or tablet PC. • Auto Commissioning & Management OUTDOORUNITS OUTDOORUNITS • WiFi Monitoring System With S-Checker, DVM S can be monitored by computers and handheld devices. With S-Checker, the commissioning time for DVM S has shortened considerably from days to a mere 50 minutes, and the test results are automatically stored and reported wirelessly. • Reduced Commissioning Time WiFi connection Check multiple outdoor equipment simultaneously Smart Phone Tablet PC DVM S Serial Port F1/F2 communication lines Conventional • Self-Diagnosis Mode DVM S monitors the operation status and displays an error code in response to any sign of abnormal operation, making it easier to solve any problems with the system. • Automatic Data Backup If a malfunction occurs with the DVM S outdoor unit, the last 30 minutes of operation data are stored for stored with automatic data backup. S-NET Pro • Easy Access With the small opening on the front side of the outdoor unit, checking the status of it and setting options is simple.
  • 8. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 1514 FLEXIBLE INSTALLATION • Longest Piping Length & Highest Elevation OUTDOORUNITS OUTDOORUNITS The knock-out holes for piping, power and communication cables are located in a variety of different areas of the condensing unit, allowing for simpler installation of DVM S where the piping and cable direction can be selected from the front, left and right side. • Versatile Piping Connection with Various Knock-Out Holes Height between indoor and outdoor units 360ft Height between indoor units (*for heat pump system) 164ft* The longest piping length 721ft Side : Communication cable outlet Non-polar communication between indoor and outdoor units makes wiring work much easier. This is also safer since the outdoor unit will protect itself if the communication cable is connected to a power teminal by mistake. • Easy and Safe Wiring Normal operation is possible even when communication cables are not connected properly ProtectedNon-polarity Indoor Unit A Indoor Unit B Indoor Unit A Indoor Unit B Power Breaker Outdoor Unit Air conditioner is protected even when power / communication cables are not connected properly DVM S DVM S Since the piping distance is far between the outdoor units and indoor units, the individual indoor units perform capacity connection control and automatic refrigerant balancing to secure balanced performance between the units. • Optimized Refrigerant Distribution Control Auto pressure correction P (Pipe pressure loss) DVM S provides the refrigerant pump-down/out functions to facilitate easy and convenient replacement of the product, as well as additional installations and maintenance. When the outdoor unit needs maintenance, it is possible for the refrigerant to recover into indoor units and pipes. It is also possible to recover refrigerant into outdoor units when moving indoor units or performing maintenance of pipes. • Refrigerant Pump-Down & Pump-Out Refrigerant Pump-out Function Refrigerant Pump-out Function To properly deal with unexpected and varying installation conditions, DVM S is designed to manage high external static pressures up to .32” H2O. • High External Static Pressure .32”H2O DVM S allows an extended piping length of up to 721ft and units will still perfom great over wide areas. With this technology, installation is available with a maximum height level of 360ft, which is equivalent to 20 stories (where each story is considered to be 16.4ft in height).
  • 9. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 1716 COMFORTABLE & RELIABLE OPERATION Without changing the outdoor unit’s settings, each duct has an indoor discharge temperature control function. This offers greater comfort in either cooling or heating mode (cooling operation: ~61°F / heating operation: ~ 97°F). • Indoor Discharge Temperature Control OUTDOORUNITS OUTDOORUNITS DVM S has applied an operation control system to the outdoor fans that drastically reduces noise level. The Quiet Operation feature lasts 12 hours, allowing you to rest in peace during the night. • Quiet Operation for Night Time DVM S can control peak current and power consumption. This is especially useful when the supply of electricity is insufficient or when you want to block excessive energy use. • Peak Power-Demand Control When you use DVM S, there’s no need to worry about using an additional unit for severe temperatures. It has a wider temperature allowance, meaning you can cool in the burning heat of 118°F or provide heat in the freezing cold of -4°F. • Wide Operating Temperatures Snow that accumulates and covers the outdoor units during the winter must be removed in order for the units to operate properly. The Snow Prevention function removes accumulated snow, so you don’t have to do it yourself. Outdoor units will blow away covered snow every 30 minutes. • Auto Snow Blowing Function The hydrophilic coating facilitates efficient heat exchange and delays the onset of frost formation to provide consistent heating performance. An anti-corrosive coating also helps our units resist corrosion from the elements. • Corrosion and Frost Resistance Too Hot Too Cold Pressure Down Pressure Up Supply of Comfortable Air Supply of Comfortable Air Less than 50dB noise Peak Operation Temperature Change Operation Mode AfterBefore Less Energy Consumption Reduced amount of electric current Maximum amount of electric current Before & after peak power-demand control Temp° F 14 50 32 68 86 104 122 SAMSUNG 23°F-118°F SAMSUNG 4°F-75°F Heating Cooling Before After Corrosion resistant finishing on heat exchanger fin Hydrophilic layer acrylic resin+surfactant Anti-corrosive layer epoxy acrylic Raw aluminum material
  • 10. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 1918 HEAT RECOVERY Single outdoor units can operate all the indoor units in both cooling and heating mode. They can also simultaneously operate in cooling and heating mode. • Simultaneous Cooling & Heating OUTDOORUNITS OUTDOORUNITS DVM S can continuously operate in heating mode with rotational defrost operation. Stay warm and comfortable as the heating mode continues for a longer period of time. • Non-Stop Heating Operation (during defrost & oil return cycle) DVM S HR uses an MCU kit that is less than 32% the size of its competitor. The MCU has an internal On/Off valve that enables control through the EEV valve control, and the sub-cooler also supports fine-tuned control. Enjoy a temperature-controlled environment through improved performance and reduced noise. • Mode Change Unit (MCU) Kit Hotel Cooling MCU Kit Office Hospital Heating Cooling operation for indoor environments where cooling load occurs all year round due to devices and lighting that generate heat. Heating operation for indoor environments where heating load occurs due to the outdoor environment. Recommended Sites MCU Kit 196lbs 57lbs SAMSUNG Company A 60” 8” 7.7” 24” 28.6”18.5” SAMSUNG CompanyA 32% Smaller 71% Lighter Weight ComparisonVolume Comparison Heating STEP 0: Normal Heating Operation STEP 1:Non-stop Heating Operation STEP 2: Non-stop Heating Operation STEP 3: Non-stop Heating Operation )2petstsorfedlanoitatoR()1petstsorfedlanoitatoR( (Rotational defrost step 3) Heating Heating DefrostingHeating Heating HeatingDefrosting Heating HeatingHeating Defrosting
  • 11. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 2120 OUTDOORUNITS OUTDOORUNITS Mini DVM ECO The footprint of the Mini DVM Eco outdoor unit has been decreased by 11% and the volume has been decreased by 5%. • Small Footprint and Volume 5dB 53/55 4HP 5HP 6HP 58/60 Conventional 4dB 51/53 55/57 Conventional 5dB 50/52 55/56 Conventional The single phase Mini DVM Eco outdoor unit can support up to 9 indoor units, and is an ideal solution for residential and semi-commercial spaces. Eco • Top-Class Energy Efficiency • Small Footprint and Volume • Flexible Piping Design • Low Noise Level COP 3.62 4.32 3.46 4.12 3.85 * Due to ongoing product development, specifications can change without prior notice. Conventional Conventional 3.39 Conventional Top-Class Energy Efficiency 4HP 5HP 6HP A Variety of Indoor Units 5% reduction Conventional 11% reduction Eco Volume Comparison Footprint Comparison Mini DVM Eco’s piping length goes up to 492ft, and a maximum level difference of 164ft. With such long distances, a variety of different system designs can be achieved. • Flexible Piping Design Level difference between Indoor and Outdoor Units 164ft 492ft The longest piping length Mini DVM Eco is quieter compared to our conventional models. • Low Noise Level
  • 12. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 2322 INDOOR UNITS Samsung’s cassette type indoor units give the finishing touch to your interior design. We also use the most advanced technologies to offer optimized comfort and pleasure. CASSETTE TYPE Duct type indoor units visually blend well into ceilings, enhancing the beauty of your interior space with their compact and slim size while giving you flexible installation options. HIGH STATIC PRESSURE (HSP) DUCT MEDIUM STATIC PRESSURE (MSP) DUCT SLIM DUCT DUCT TYPE With their stylish and sophisti- cated designs, Samsung wall mounted type air conditioners offer cool, clean, and healthy freshness enhancing your everyday life. NEO FORTE WALL MOUNTED Samsung’s ceiling/floor type installs on the ceiling (non-recessed) and low-wall installation near the floor for a more efficient and convenient installation. No modification is needed with this multi-position unit. CEILING / FLOOR MOUNT CEILING/FLOOR MOUNT 4 WAY CASSETTE Wide blades in the indoor unit deliver cool or warm air at greater distances to provide even cooling and heating throughout the room. • Powerful Airflow With its newly improved design, the 4 Way Cassette brings sophistication and provides clean air while adding a sense of class to your interior. Not only is this unit attractively designed, it also uses advanced technologies to optimize your comfort in any environment. Feel the power and enjoy the beauty with the new 4 Way Cassette. Available Capacities: 9,500 / 18,000 / 24,000 / 30,000 / 36,000 / 48,000 BTU PRODUCT FEATURES 1-Way Cassette New Blade Conventional 4-Way Cassette The newly designed panel will control air direction in a way to avoid contact with the ceiling. This new design will prevent dust from accumulating on the ceiling after long periods of operation, keeping your interior space cleaner than ever. • Ceiling Dust Prevention New BladeConventional Blade Ceiling Ceiling INDOORUNITS INDOORUNITS MINI 4 WAY CEILING CASSETTE 4 WAY CEILING CASSETTE 1 WAY CEILING CASSETTE
  • 13. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 2524 4 WAY CASSETTE FEATURES CONTINUED . . . The lift-up drain pump lifts condensed water up to 29.5” compared to our competitor’s limit of 27.5”, making installation more flexible and convenient. • High-Lift Up Drain Pump Fresh air can enter through the cassette unit so you can enjoy even fresher air in your room. • Fresh Air Intake Max:29.5” Ceiling Company A Lift-up Range 29.5” 27.5” SAMSUNG Fresh Air Sub Duct enables you to use the same air conditioner unit to cool an additional smaller space nearby. (A cassette unit is fitted with a knockout component to accommodate this). • Sub Duct The simple display design with its rounded corners adds a neat and tidy feeling to your interior. • Simple Display Power Time Defrost Clean Power Defrost Time Clean The 4 Way Cassette uses a new, neat and clean design. The completely hermetic blade structure keeps the indoor unit clean preventing dust or other foreign substances from entering the unit. The internal parts of the indoor unit are also out of sight when the blade is shut, improving the unit’s appearance. • Neat and Clean Design Samsung’s 4 Way Cassette indoor unit is now lighter in weightat 37.5lbs. It is the lightest of its type in the industry, about 35% lighter than our competitor’s 4-way cassette. • Light Yet Robust Design Based on 10kW 40% 64lbs37.5lbs Conventional4Way Cassette S By using the remote controller, the opening angles of the 4 blades can be individually set at the same or different angles within a 32°- 65° range for more efficient cooling. • Individual Blade Control The check valve on the drain pump prevents drained water from flowing backward into the drain pan. This minimizes the the drain pan’s water level so that you will never have to worry about water stagnation or overflowing drain water that could drip into your interior. • No Overflowing Drain Water ONE-WAY FLOW CLEAN CEILING NO STAGNATIONNO OVERFLOW Check Valve: Prevents drain water from reversing W H Minimizes Remaining Drain Water INDOORUNITS INDOORUNITS 4 WAY CASSETTE . . .
  • 14. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 2726 4 WAY CASSETTE FEATURES CONTINUED . . . • Easy Leveling Each corner portion of the panel is detachable: this makes it easier for you to adjust the height, and makes installation and leveling much simpler and quicker. • Easy Blade Cleaning Samsung’s 4 Way Cassette indoor units have detachable air flow blades so you don’t need to remove the entire panel to clean the blades. • Quick Cooling & Heating Samsung’s 4 Way Cassette indoor unit achieves the desired set temperature much faster than our competitor’s products. 0 1200 2400 3600 4800 6000 7200 8400 9600 10800 12000 23.5 22.0 20.5 19.0 17.5 16.0 14.5 13.0 11.5 10.0 2500 2000 1500 1000 500 0 1 2 0 0 2 4 0 0 3 6 0 0 4 8 0 0 6 0 0 0 7 2 0 0 8 4 0 0 Conventional • Turbo Fan High Ceiling Mode • Fan Speed Adjustment for High Ceiling The optimum fan speed for high ceiling can be achieved just by using the remote controller without adjusting the DIP switch on the indoor unit’s PCB. The fan speed adjustment function provides evenly cool and warm air throughout spaces with high ceiling of up to 11.5ft. The high ceiling mode allows indoor units to provide even more powerful airflow throughout your space. This mode enlarges the coverage area of the airflow up to a height of 15ft. Fan Speed Adjustment 4 Way Cassette Conventional Applied via remote controller 11.5ft Not applied 8.5ft 15ft 12ft High Ceiling Mode Imagine a room of cool calmness. The aerodynamically designed Turbo Fan minimizes noise from the turbulence of the blade movement, meaning our units make less noise than conventional models. 1. Silent Operation 2500 2000 1500 1000 500 0 1 2 0 0 2 4 0 0 3 6 0 0 4 8 0 0 6 0 0 0 7 2 0 0 8 4 0 0 0 1200 2400 3600 4800 6000 7200 8400 9600 10800 12000 23.5 22.0 20.5 19.0 17.5 16.0 14.5 13.0 11.5 10.0 SAMSUNG Faster 25%Heating after approximately 30 minutes Heating after approximately 40 minutes The Turbo Fan with wide blades provides extreme cooling and heating power from 4 separate outlets so the entire room cools down or warms up faster. This unit can extend comfort to every nook and cranny of the room. 2. Uniform Distribution Conventional4Way Samsung4Way Conventional4Way Samsung4Way Conventional4Way Samsung4Way Conventional4Way Samsung4Way CFM CAE Analysis Results 353 460 • Surround Air Flow The 4 Way outlet can cool every portion of your room. The new and practical design of the blades minimizes blind spots at the corners of the panel, and can almost cover a full 360° around the indoor unit. Covers 360O INDOORUNITS INDOORUNITS 4 WAY CASSETTE . . .
  • 15. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 2928 MINI 4 WAY CASSETTE Available Capacities: 9,500 / 12,000 / 18,000 / 20,000 BTU Wide blades in the indoor unit deliver cool or warm air at greater distances to provide even cooling and heating throughout the room. • Powerful Airflow 1-Way Cassette New Blade Conventional 4-Way Cassette The newly designed panel will control air direction in a way to avoid contact with the ceiling. This new design will prevent dust from accumulating on the ceiling after long periods of operation, keeping your interior space cleaner than ever. • Ceiling Dust Prevention Conventional Blade Ceiling PRODUCT FEATURES The lift-up drain pump lifts condensed water up to 29.5ft compared to our competitor’s limit of 27.5mm, making installation more flexible and convenient. • High-Lift Up Drain Pump Company A Lift-up Range 29.5ft 27.5ft Fresh air can enter through the cassette unit so you can enjoy even fresher air in your room. • Fresh Air Intake SAMSUNG Fresh Air Sub Duct enables you to use the same air conditioner unit to cool an additional smaller space nearby. (A cassette unit is fitted with a knockout component to accommodate this). • Sub Duct The simple display design with its rounded corners adds a neat and tidy feeling to your interior. • Simple Display Power Time Defrost Clean Power Defrost Time Clean INDOORUNITS INDOORUNITS
  • 16. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 3130 • High-Lift Up Drain Pump MINI 4 WAY CASSETTE FEATURES CONTINUED . . . The Mini 4 Way Cassette can be installed on one standard ceiling tile (23.6” x 23.6”), making installation more convenient. • Ideal Compact Size 23.6” 24.5” 24.5” The Mini 4 Way Cassette uses a new, neat and clean design. The completely hermetic blade structure keeps the indoor unit clean preventing dust or other foreign substances from entering the unit. The internal parts of the indoor unit are also out of sight when the blade is shut, improving the unit’s appearance. • Neat and Clean Design Not only is the Mini 4-Way Cassette compact enough to be installed on one standard ceiling tile, it’s also lighter than a conventional mini 4 way cassette (38.5lbs) by about 35% (24.3lbs). • Compact and Light Unit By using the remote controller, the opening angles of the 4 blades can be individually set at the same or different angles within a 32°- 65° range for more efficient cooling. • Individual Blade Control 35% 38.5lbs24.3lbs ConventionalMini 4 Way Cassette • Motion Detector Sensor The world’s first motion detector sensor for Samsung’s Mini 4 Way Cassette creates the ideal environment, saving energy by providing the optimized amount of airflow when needed. Power ON Power OFFThe Motion Detector Sensor detects when the user is absent, automatically stopping the air conditioning. It also automatically sets operation patterns to maximize energy efficiency. Energy Saving On/Off Function The check valve on the drain pump prevents drained water from flowing backward into the drain pan. This minimizes the the drain pan’s water level so that you will never have to worry about water stagnation or overflowing drain water that could drip into your interior. • No Overflowing Drain Water ONE-WAY FLOW CLEAN CEILING NO STAGNATIONNO OVERFLOW Check Valve: Prevents drain water from reversing W H Minimizes Remaining Drain Water • Surround Air Flow The 4 Way outlet can cool every portion of your room. The new and practical design of the blades minimizes blind spots at the corners of the panel, and can almost cover a full 360° around the indoor unit. Covers 360O INDOORUNITS INDOORUNITS MINI 4 WAY CASSETTE . . .
  • 17. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 3332 1 WAY CASSETTE Available Capacities: 7,500 / 9,500 / 12,000 BTU Wide blades in the indoor unit deliver cool or warm air at greater distances to provide even cooling and heating throughout the room. • Powerful Airflow 1-Way Cassette New Blade Conventional 4-Way Cassette The newly designed panel will control air direction in a way to avoid contact with the ceiling. This new design will prevent dust from accumulating on the ceiling after long periods of operation, keeping your interior space cleaner than ever. • Ceiling Dust Prevention Conventional Blade Ceiling PRODUCT FEATURES The lift-up drain pump lifts condensed water up to 29.5ft compared to our competitor’s limit of 27.5mm, making installation more flexible and convenient. • High-Lift Up Drain Pump Company A Lift-up Range 29.5ft 27.5ft SAMSUNG Samsung new blade design drastically reduces noise levels so you can relax in peace and quiet. • Quiet Operation • Stylish and Aesthetic Panel Samsung’s Slim 1Way Cassette provides a simple and refined design. The clean lines and simple display design make this a modern classic, which looks great with any interior. Samsung is the first to apply ABS cabinets to its indoor units to provide the lightest units on the market. This slim and lightweight design makes installation and maintenance simple. • Lighter Indoor Unit Weight 21.8lbs 68lbs Conventional DVMS 25dB 30dB Noiselevel 32% Down 26% Down SAMSUNG SAMSUNG CompanyA Low Fan Speed High Fan Speed The check valve on the drain pump prevents drained water from flowing backward into the drain pan. This minimizes the the drain pan’s water level so that you will never have to worry about water stagnation or overflowing drain water that could drip into your interior. • No Overflowing Drain Water ONE-WAY FLOW CLEAN CEILING NO STAGNATIONNO OVERFLOW Check Valve: Prevents drain water from reversing W H Minimizes Remaining Drain Water INDOORUNITS INDOORUNITS 1 WAY CASSETTE . . .
  • 18. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 3534 HSP DUCT Available Capacities: 36,000 / 48,000 / 76,000 / 96,000 BTU The HSP Duct’s Pre Filter traps dusts particles from the air. • Pre Filter PRODUCT FEATURES After 1,000 hours of operation, the filter clean indicator will notify you that the filter should be cleaned. The filter can be easily removed from the bottom, left, or right of the unit. (1,000 hours is the default set time, which can be adjusted to 2,000 hours on the internal PCB). • Easy Filter Cleaning The Smart Pressure Control System adjusts fan speed according to the external static pressure so the air conditioner always provides you with consistent cooling and heating power, regardless of the surrounding environment. • Smart Pressure Control AirVolume Static pressure (inches of water) Minimum Maximum H H M L L M The HSP Ducted unit is controlled via a wired remote controller. • Wired Remote Control • High Lift-Up Drain Pump* (Optional) The lift-up drain pump lifts condensed water up to 29.5”, compared to our competitor’s limit of 23.5”, making installation more flexible and convenient. Max:29.5” Ceiling * The lift-up range of the drain pump for the HSP is limited to 18.5”. To properly deal with unexpected and various installation conditions, the HSP Duct is designed to manage high external static pressures up to .99” H2O. • High External Static Pressure .79” H2O HSPDuct HSPDuct .99” H2O 3-4 TON 6-8 TON Samsung’s HSP Duct features greater static pressure than most slim ducts: enabling you to design more inlets and outlets with longer duct work to provide even more cool or warm air to larger areas. • Large Coverage Area .99” H.99” H2O.99” H2O.24” H.24” H2O.24” H2O HSP DuctSlim Duct INDOORUNITS INDOORUNITS HSP DUCT . . .
  • 19. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 3736 The external static pressure control makes it easy to design the duct work to ensure efficiency and silent operation. • Silent Operation with Static Pressure Control HSP DUCT FEATURES CONTINUED . . . Time and maintenance costs are reduced with parts being easily accessible. • Easy to Maintain MSP DUCT Available Capacities: 18,000 / 24,000 / 30,000 / 36,000 / 48,000 BTU PRODUCT FEATURES The HSP Duct’s Pre Filter traps dusts particles from the air. • Pre Filter After 1,000 hours of operation, the filter clean indicator will notify you that the filter should be cleaned. The filter can be easily removed from the bottom, left, or right of the unit. (1,000 hours is the default set time, which can be adjusted to 2,000 hours on the internal PCB.) • Easy Filter Cleaning The Smart Pressure Control System adjusts fan speed according to the external static pressure so the air conditioner always provides you with consistent cooling and heating power, regardless of the surrounding environment. • Smart Pressure Control AirVolume Static pressure (inches of water) Minimum Maximum H H M L L M INDOORUNITS INDOORUNITS
  • 20. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 3938 MSP DUCT FEATURES CONTINUED . . . Samsung’s MSP Duct is controlled via a wired remote controller. • Wired Remote Control • High Lift-Up Drain Pump (Optional) The lift-up drain pump lifts condensed water up to 29.5”, compared to our competitor’s limit of 23.5”, making installation more flexible and convenient. Ceiling Samsung’s MSP Duct features greater static pressure than most slim ducts: enabling you to design more inlets and outlets with longer duct work to provide even more cool or warm air to larger areas. • Large Coverage Area .99” H.99” H2O.55” H2O.24” H.24” H2O.24” H2O MSP DuctSlim Duct The external static pressure control makes it easy to design the duct work to ensure efficiency and silent operation. • Silent Operation with Static Pressure Control Max:29.5” The MSP Duct has a very narrow width of 35.43”, making installation and maintenance more flexible, maximizing your convenience. • Narrow Width* 35.43” *Measured without control box Parts are easily accessible, reducing the time for maintenance. • Simple Maintenance INDOORUNITS INDOORUNITS MSP DUCT . . .
  • 21. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 4140 SLIM DUCT Available Capacities: 7,500 / 9,500 / 12,000 / 18,000 / 24,000 / 30,000 / 36,000 / 48,000 BTU The Slim Duct’s Pre Filter traps dusts particles from the air. • Pre Filter PRODUCT FEATURES After 1,000 hours of operation, the filter clean indicator will notify you that the filter should be cleaned. The filter can be easily removed from the bottom, left, or right of the unit. (1,000 hours is the default set time, which can be adjusted to 2,000 hours on the internal PCB.) • Easy Filter Cleaning The Smart Pressure Control System adjusts fan speed according to the external static pressure so the air conditioner always provides you with consistent cooling and heating power, regardless of the surrounding environment. • Smart Pressure Control AirVolume Static pressure (inches of water) Minimum Maximum H H M L L M • High Lift-Up Drain Pump (Optional) The lift-up drain pump lifts condensed water up to 29.5”, compared to our competitor’s limit of 23.5”, making installation more flexible and convenient. Max:29.5” Ceiling The Slim Duct is controlled via a wired remote controller. • Wired Remote Control The Slim Duct has a narrow width, which is 7.9” slimmer than conventional products: this enables flexible installation and maintenance in various spaces. • Compact Size 35.43” 27.56” 7.9”Slimmer Samsung’s Slim Duct operates at a remarkably low sound level, lower than the inside of a library, letting you enjoy comfort in a quiet and peaceful environment. • Quiet Operation 26dB 29dB 31dB 33dB Noiselevel 11% Down 6% Down SlimDuctS Conventional SlimDuctS Conventional Low Fan Speed High Fan Speed INDOORUNITS INDOORUNITS SLIM DUCT . . .
  • 22. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 4342 SLIM DUCT FEATURES CONTINUED . . . The Slim Duct is the lightest duct on the market, and is about 15% lighter than our competitor’s products. This feature makes it favorably easy and convenient to install and maintain. • The Lightest Weight The air inlet can be set up either on the bottom or rear of the unit, giving you more flexibility during installation. • Flexible Installation Weight 41.8lbs 50.7lbs 21% Lighter Slim Duct Conventional TEX Suction Duct Diffuser Diffuser Suction Duct TEX Rear Side Air Inlet Bottom Side Air Inlet Parts can be accessed simply by opening the bottom panel, simplifying maintenance. • Easy to Maintain The new drain pump can be installed from the side by simply removing the right side panel. You no longer need to disassemble the top cover to install, check or repair the drain pump. • Easier Drain Pump Installation HIGH WALL Available Capacities: 7,500 / 9,500 / 12,000 / 18,000 / 20,000 / 24,000 BTU PRODUCT FEATURES Sleep with the air conditioner off, and it gets hot. Sleep with it on, and it gets too cold. With Samsung’s Good Sleep Mode, you can stay comfortable because the room temperature automatically adjusts to your body temperature before, during and after you sleep. • Good Sleep Mode INDOORUNITS INDOORUNITS Stage 01: Falling asleep Eases you into sleep by dropping the temperature. Stage 02: Sound asleep Relaxes your body and raises your temperature slightly. Stage 03: Wake up You wake up to intermittent comfortable air, making you feel refreshed and rested. Falling asleep 01 Cooling mode Sound sleep 02 Wake up 03 1 2 3 4 5 6 7 8 Time(hr.) Heating mode Till 1hr Till 8 hrs2 to 7 hrs Best Temperature for Deep Sleep
  • 23. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 4544 HIGH WALL FEATURES CONTINUED . . . Incorporated with activated carbon, the deodorizing filter efficiently absorbs cigarette smoke, pet odors and other unpleasant smells. • Deodorizing Filter CEILING / FLOOR Available Capacities: 18,000 / 24,000 BTU PRODUCT FEATURES The Pre Filter helps you stay comfortable by trapping dust particles from the air. • Pre Filter Samsung’s Smart Inverter technology maintains the ideal temperature without the constant shutting off and on of the compressor. • Smart Inverter Uncomfortable (Energy Loss) Uncomfortable (Energy Loss) Set Temperature Comfortable Smart Inverter automatically adjusts power to cope with any variances, assuring you experience less temperature fluctuations for optimal comfort. Smart Inverter Uncomfortable (Energy Loss) Uncomfortable (Energy Loss) Comfortable Loss Loss Loss Loss Non Inverter High Temperature Fluctuation Non inverter air conditioners shut off when the set temperature is reached and turns back on when the temperature variance is high, causing large fluctuations in temperature and comfort. Non inverter Mounted either on the floor or ceiling, the Ceiling/Floor Mount unit blends well with any interior, enhancing the decor and adding to the overall ambiance of the room. • Interior Design INDOORUNITS INDOORUNITS
  • 24. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 46 CEILING/FLOOR MOUNT FEATURES CONTINUED . . . • Lightweight INDOORUNITS Depending on the available space and the purpose of the air conditioner, the indoor unit can be installed under the ceiling or on the floor giving you flexibility and convenience. • Flexible 2-Way Installation Ceiling Floor Because Samsung’s Ceiling/Floor Mount unit is light in weight, installation is more convenient Samsung’s Ceiling/Floor Mount air conditioner boasts a slim, compact design - half the size of our competitor’s with cooling power comparable to our competitor’s larger products. • Compact but Powerful 118% CompanyA 200% CompanyB 100% SAMSUNG 123% CompanyA 136% CompanyB 100% SAMSUNG Smaller Lighter Size Weight CONTROLS CONTROLS INDIVIDUAL CONTROL CENTRAL CONTROL APPLICATIONSBUILDING MANAGEMENT WIRED REMOTE CONTROL Part No. MC-A202DN DMS 2 Part No. MIM-DOOAN WIRED REMOTE CONTROL Part No. MWR-WE10N WIRELESS REMOTE CONTROL Part No. MWR-DH00U EXTERNAL CONTACT INTERFACE MODULE Part No. MIM-B14 EXTERNAL TEMP SENSOR Part No. MRW-TA DUCT UNIT WIRELESS CONTROL Part No. MRK-A10N BACnet GATEWAY Part No. MIM-B17N LonWorks GATEWAY Part No. MIM-B18N HEATPUMP MODE SELECTOR SWITCH Part No. MC-C200 SNET 3 SOFTWARE Part No. MST-P3P ENERGY MANAGEMENT Part No. MIM-B16N S-CHECKER iCONVERTER Interface Module Watt-Hour Meter S-NET mini Wireless Remote Controller Wired Remote Controller Wireless Remote ControllerCentrallized Controller External Contact Interface Module LonWorks Gateway Wireless Remote Controller PIM DMS 2 47 Remote Control Internet Current temp °F Desired temp °F TOUCHSCREEN CONTROLLER Part No. MCM-A300N
  • 25. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 4948 WIRED REMOTE CONTROL CONTROLS INDIVIDUAL CONTROL WIRELESS REMOTE CONTROL • On/Off, Operation Mode, Fan Speed, Airflow, Temperature Setting • Filter replacement alarm reset • Simple schedule control • Wide display • Soft touch button • Individual blade control (supports specific indoor unit models) • Multi-channel wireless remote control (maximum of 4 channels) MR-DH00U CONTROLS • External sensor to measure exact user environment temperature • Wire length : 39ft. MRW-TA EXTERNAL TEMPERATURE SENSOR • On/Off, Operation Mode, Fan Speed, Airflow, Temp Setting • Individual and group control (maximum to 16 indoor units) • Error display • Filter replacement alarm reset • Sleep & Silent mode • Built-in room temperature sensor • Child lock • Automatic stop mode • Wireless remote control restriction • Clear & bright screen with LCD backlight • Unified controller • Different permission levels • Weekly schedule setting • Exception date setting • Individual blade control (supports specific indoor unit models) • Summer time MWR-WE10N Samsung’s MWR-WE10N wired controller allows connection of up to 16 Samsung indoor units. Features include: built-in room sensor, air handler operation on/off, air handler operation mode, set temperature, air flow direction, fan speed, discharge air temperature setting (with supported indoor unit models), quiet and sleep modes, error display, filter replacement alarm display and reset, weekly operating schedule, different button permission levels, partial button lock option, backlight, temperature limit setting option, service mode support, independent louver control for DVM S series 4-way cassette models (AM0**FN4DCH), adjustable heating temperature compensation values, and child lock. • Direct indoor unit control by external contact signal • Window-synchronized indoor unit control • Emergency control with simple contact input • Indoor unit operation / error state output through relay contacts MIM-B14 (External Contact Interface Module) GUESTROOM MANAGEMENT MODULE Direct indoor unit ON/OFF control (a single evaporator) by external contact, 0 volts signal. Also provides operation and error output terminals to control other devises/indicator lights with a dry-contact. E.G.: hotel key card switch, door/window switch, PIR sensor with timed relay, other occupancy sensors, enabling/disabling other ventilation. • On/Off control • Operation indication • Error Indication • Filter replacement sign • Use with receiver wire, MRW-10A MRK-A10N DUCT UNIT WIRELESS CONTROL MRW-10A (Wall-mounted Type Indoor Units : Only models that include EEV support state output function.) On/Off Key-Tag On/Off Window Open Sensor Error Malfunction Alarm On/Off External Device Control
  • 26. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 51 CONTROLS CENTRAL CONTROL CONTROLS ON/OFF CONTROLLER MIM-D00AN • Built-in web server for PC-independent management and remote access control • Multiple upper-level control access (S-NET 3, Touchscreen Control, Web-client) • Central management of up to 256 indoor units • User editable control logic • Accessible level management • Dynamic security management • Operation & error history management • Weekly/Daily schedule control • Power distribution function • Current time management even during power failure (for 24 hours) • Data storage in non-volatile memory & SD memory • Emergency stop function with simple contact interface DMS 2 PIM Watt Hour Meter Centralized Controller Watt Hour MeterPIM DMS 2 System 50 Standalone web server device that can connect to and control up to 256 indoor units via Internet Explorer. The DMS 2 provides a simple, easy to use interface for control of the following: indoor unit operation mode, temperature setting, airflow direction, fan speed, temperature and mode limitations and restrictions, maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or MIM-D00AN, heating and cooling output calibration of indoor units, and other various control points. To fit the needs of the commercial building, multiple user login accounts can be created with various levels of control for manager specified indoor units. The DMS 2 shall also offer 10 Digital Input (2 reserved for system shutdown with emergency signal) and 8 Digital Output terminals (2 reserved) to control and monitor other devices on the project.• Maximum of 16 group controls (Maximum of 256 Indoor units) • Unified/Individual indoor unit control (On/Off) • Wireless/wired remote control restriction • Cooling/Heating mode control • Indoor unit error display MC-A202DN MCM-A202DN is a simple to use device that allows ON/OFF control of up to 128 indoor units with up to 16 individual groups. The MCM-A202DN also has a mode selection switch that allows easy system operation mode changes along with ALL ON and ALL OFF buttons.
  • 27. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 5352 CONTROLS CONTROLS CENTRAL CONTROL DMS 2 CONTINUED . . . Air Conditioning Operation Monitoring High Pressure Fan Motor RPM Current Data Time Easy Control & Monitoring • Control and monitoring of up to 256 indoor units via internet network • Operation On/Off • Operation mode, fan speed, temperature setting • No need to open each outdoor unit • Detailed refrigerant flow check in control room • Reduced service lead time Anytime. Anywhere Control Indoor Unit On/Off Time Storage • Operation history data recorded for up to 6 months Storage parameters 1. Indoor unit address and name 2. On/Off time (year, month, day, hour, minute) 3. Operation mode (Cool, Heat, Auto, Fan, Dry, Stop) 4. Set/Room temperatures Storage Period - Up to 6 months Flexible Connectivity Administrator User_A User_B User_C User_D Accessible Level Management • It is possible to specify the scope of control and monitoring by each user. Dynamic User Security Management • General users, managers, and administrators can be registered separately by ID and password. Administrators (utility managers) have the authority to set access levels for DMS 2 functions on users. Functions Admin Manager User Access All Changeable Control / Monitoring O O O Zone Management O O X Schedule O O O Power Distribution O O X System Configuration O X X • Indoor unit control via centralized controllers or interface modules directly • Select connection point according to the site Small & Medium Size Connect interface module only Large Size Connect centrallized controllers DMS 2 . . .
  • 28. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 5554 CONTROLS CONTROLS CENTRAL CONTROL DMS 2 CONTINUED . . . Enhanced Graphical User Interface Data Backup • Important data is safely stored on SD memory card Service Response • Remote control and monitoring through the Internet (when a public IP is used) • E-mail notification to private internet account in case of malfunction User-friendly icon-based unit control Zoom in & Zoom out icon display Convenient & stylish controller Color indication and icons make it easy to recognize indoor unit status Current temp. Desired temp. Current temp. Desired temp. 68° F 74° F 68° F 74° F 68° F 74° F68° F 74° F 1. Indoor/outdoor unit name 2. Power distribution data 3. Operation history (On/Off by DMS) 4. DMS power On/Off history 5. System configuration 6. Others Automatic system recovery after Service DMS 2 . . . User Editable Control Logic • User can edit control logic with arithmetic / conditional operators and parameters • Energy can be efficiently used and reduced for various operation conditions Example : Energy saving function, operation adjustment depending on outdoor temperature EHP / ERV / AHU Parameters Arithmetic Equation FunctionAND OR EHP / ERV / AHU Parameters change ......deepsnaF,edoM,rewoP,pmetgnitteSegarevA,<=,>=,=,>,<......edoM,rewoP,erutarepmeT Logic Outdoor temp < Room temp Control Turn ON ERV Outdoor temp < 50°F Heating mode Cooling mode Room Outdoor WINTER SUMMER Room temp < Outdoor temp (Cool air Intake UP) Turn ON Air Conditioner Useful History Management • DMS 2 records indoor unit operation and error occurrence history. • Recorded history makes it convenient to analyze air conditioner operation and perform unit maintenance. 1. Operation On/Off execution time 2. Daily accumulated operation On time 3. Schedule operation execution time Operation History 1. Error occurred unit name 2. Error details 3. Error occurrence/clear time 4. Error state (solved / unsolved) Error History Outdoor temp > 75°F More Extended Contact Interface General users, managers, and administrators can be registered separately by ID and password. Administrators (utility managers) have the ability to set access levels for DMS 2 functions on users. Building Control System Fire Control System Operation Restriction Error Status Indicator
  • 29. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 5756 CONTROLS CONTROLS CENTRAL CONTROL DMS 2 CONTINUED . . . Power Distribution System • Power distribution to a maximum of 256 indoor units • Data query for watt-hour, usage time and usage ratio • Files are saved in Microsoft® Excel® format • 1-year power distribution data is saved in storage • Current actual power consumption monitoring • Current-type electricity meter support (CT ratio input) 140kWh 5th Floor 610kWh 4th Floor 460kWh 3rd Floor 360kWh 2nd Floor 180kWh 1st Floor Indoor Unit Operation State 1. Operation Data Accumulation and Power Distribution 2. Data Extract - Excel Format Smart Central Management • Control & monitoring zone edition • Wireless/wired remote control restriction • Temperature limit setting • Operation mode restriction Cooling only / No remote controller / Minimum cooling temperature setting is 68°F Cooling only / Remote controller useB Zone A Zone A Zone B Zone BACnet GATEWAY MIM-B17N (DMS-Bnet) • Interface for BACnet management system • Maximum 256 indoor units plus ERVs support with a maximum of 80 interface modules • Combinational use of BACnet and S-NET 3/ S-NET Mini • Includes DMS 2 functions • On/Off control • Operation mode • Temperature setting • Fan speed/direction • ERV operation mode • ERV fan speed • Filter alarm reset • User control restriction • Operation mode lock • Set temperature limit • Emergency stop • Output contact control CONTROL • On/Off control • Operation mode • Set/Room temperature • Fan speed/direction • ERV operation mode • ERV fan speed • Filter alarm • User control restriction • Thermo On/Off • Power distribution • Operation mode lock • Set temperature limit • In/Out contact state • Emergency stop • Error code MONITORING BACnet Gateway Setup Ethernet RS485 Ethernet BACnet Gateway Standalone web server device that can connect to and control up to 256 indoor units via Internet Explorer. The MIM-B17 provides a simple, easy to use interface for control of the following: indoor unit operation mode, temperature setting, airflow direction, fan speed, temperature and mode limitations and restrictions, maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or MIM-B17, heating and cooling output calibration of indoor units, and other various control points. To fit the needs of the commercial building, multiple user login accounts can be created with various levels of control for manager specified indoor units. The MIM-B17 shall also offer 10 Digital Input (2 reserved for system shutdown with emergency signal) and 8 Digital Output terminals (2 reserved) to control and monitor other devices on the project. The MIM-B17 will also interface with BACnet systems to allow full integration with building management systems.
  • 30. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 5958 CONTROLS CONTROLS CENTRAL CONTROL LonWorks GATEWAY MIM-B18N (DMS-Lnet) • Interface for Lon-Connection to LonWorks management system • Max. 128 indoor units plus ERVs support with a maximum of 80 interface modules • Works with LonWorks and S-NET 3 • Includes DMS 2 functions • On/Off control • Operation mode • Set/Room temperature • Fan speed/direction • ERV operation mode • ERV fan speed • Filter alarm • User control restriction • Thermo On/Off • Power distribution • Operation mode lock • Set temperature limit • In/Out contact state • Emergency stop • Error code MONITORING LonWorks Gateway Setup Ethernet RS485 FTT-10A LonWorks BMS CONTROL • On/Off control • Operation mode • Temperature setting • Fan speed/direction • ERV operation mode • ERV fan speed • Filter alarm reset • User control restriction • Operation mode lock • Set temperature limit • Emergency stop • Output contact control HEAT PUMP MODE SELECTOR SWITCH • Operation mode selection (Cooling, Heating or Auto) • Mixed operation mode protection MC-C200 Standalone web server device that can connect to and control up to 128 indoor units via Internet Explorer. The MIM-B18 provides a simple, easy to use interface for control of the following: indoor unit operation mode, temperature setting, airflow direction, fan speed, temperature and mode limitations and restrictions, maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or MIM-B18, heating and cooling output calibration of indoor units, and other various control points. To fit the needs of the commercial building, multiple user login accounts can be created with various levels of control for manager specified indoor units. The MIM-B18 shall also offer 10 Digital Input (2 reserved for system shutdown with emergency signal) and 8 Digital Output terminals (2 reserved) to control and monitor other devices on the project. The MIM-B18 will also interface with LonWorks systems to allow full integration with building management systems.
  • 31. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 6160 TOUCHSCREEN CONTROLLER Control and Monitoring CONTROLS MCM-A300M* • Control & monitoring of up to 256 indoor units • Operation control and monitoring • Detailed operation cycling information monitoring • Wireless/Wired remote control restriction setting CONTROLS The Touchscreen Controller supports up to 4 DMS 2’s to provide the same remote control functions as the S-NET 3. It can be directly connected to the system air conditioner through the centralized controller or interface modules, allowing for the control of up to 256 indoor units. Current temp °F Desired temp °F *Touchscreen controller may be updated and have a different appearance than shown above. Due to ongoing product development, some features for the MCM-A300N may change without prior notice. • Flexible compatibility options (DMS 2, centralized controller) • Central management of up to 256 indoor units • Detailed cycling information monitoring • Schedule function (Weekly, Daily) • USB keyboard support • Error display • LCD display • Temperature limit setting • Touch screen • Zone control • Child-lock setting • Operation mode lock • External contact control Supports 4 Current temp °F Desired temp °F Supports 16 Centrallized Controllers MCM-A300M MCM-A300N Setup Current temp °F Desired temp °F Schedule Control • Maximum 256 Weekly, Daily schedule control • Schedule repetition, exception date setting • Schedule edit (add, edit, delete) • Detailed operation schedule setting • Remote control restriction option setting Zone Management • Management structure customization regardless of installation structure • Control zone creation/edition/deletion Central Restriction Function • Upper/Lower temperature limit setting • Operation mode lock °F °F Cycle Monitoring • Monitoring outdoor/indoor unit cycle data (The monitoring function is supported for specific outdoor unit models) Error Management • Error history management • Error management information query • Detailed error information query CENTRAL CONTROL TOUCHSCREEN CONTROLLER . . .
  • 32. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 6362 S-NET 3 CONTROLS • Fully integrated PC management software • Up to 16 DMS 2 connections through the Internet • Central management of up to 4,096 indoor units • Schedule/Zone control • Error/Operation history management • Power distribution management and analysis MST-P3P Supports16 CONTROLS S-NET 3 System Centralized Controller SNET 3 . . . Samsung Software that allows monitoring and control of up to 16 DMS 2’s, Samsung BACnet Gateways, or Samsung LonWorks gateways via LAN connection. SNET 3 provides a simple, easy to use interface for control of the following: indoor unit operation mode, temperature setting, airflow direction, fan speed, temperature and mode limitations and restrictions, gateway Digital Inputs and Digital Outputs, and other various control points. To fit the needs of the commercial building, multiple user login accounts can be created with various levels of control for manager specified indoor units. SNET 3 shall also offer energy management query for tenant billing and energy reports (other components necessary). SNET 3 offers a single point for control for a single building or multiple buildings via public IP. Control and Monitoring • Control & monitoring of up to 4,096 indoor units • Wireless/Wired remote control restriction • Temperature limit setting • Operation mode lock • Multiple/Full indoor unit selection • Icon-based indoor unit display mode Power Distribution Management • Data query for power distribution and operation time • Power distribution report generation and printing • Time section setting for different electricity rates • Group setting for power distribution summary Schedule Control • Graphical schedule settings • Weekly, Daily schedule control • Exception date setting History Management • Error/Event history management • Indoor unit operation history management • Report generation and printing Zone Management • Management structure customization regardless of installation structure • Control zone creation/edition/deletion • Tree structure zone management control Cycle Monitoring • Monitoring outdoor/indoor unit cycle data (The monitoring function is supported for specific outdoor unit models) BUILDING MANAGEMENT
  • 33. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 6564 CONTROLS CONTROLS BUILDING MANAGEMENT WATT-HOUR METER INTERFACE MODULE MIM-B16N (Pulse Input Module) • Exclusive use for DMS 2 power distribution • Connection with up to 8 watt-hour meters • Pulse interface with watt-hour meters • Power consumption display for each watt-hour meter The Watt-Hour Meter Interface Module can be exclusively used for DMS 2 power distribution, displaying power consumption for each watt-hour meter. Pulse Input Module Setup Supports Max.8 Supports Max.8 Pulse Input Module (PIM) Pulse Input Module (PIM) Centralized Controllers PIM Watt Hour Meters ShortShort Short Open Open More than 3ms (mandatory) APPLICATIONS S-CHECKER With S-Checker, DVM S can be monitored by smart devices such as smart phone or tablet PC. Facilitates self-diagnosis, auto commissioning, auto management, and mobile data transmission.
  • 34. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 6766 DVM PRO DVM Pro is a selection program that allows you to design your DVM S system with ease and precision. Sales Mode • Indoor Unit & Outdoor Unit : Indoor unit and outdoor unit connection with accessories • Piping : Basic or manual selection with system check and capacity simulation • Wiring : Automatic diagram with communication wiring of indoor/outdoor/control units and electric power meters • Control system: Automatic control unit selection • Report : Specifications, diagrams with DWG & BMP format, quotation CAD Mode • Quick, Easy, Precise Design • AutoCAD add-on software (AutoCAD is not included with DVM-Pro) • Automatic Calculation : Refrigerant & drain pipe size • Automatic Selection : Refnet joint, header & distributor kit • System Check : Installation regulation & refrigerant addition • Easy Control System Selection • Automatic Report : Piping installation diagram, equipment list & quotation DVM Pro can be downloaded at www.samsungdvm-s.com or www.dvmdownload.com NOTES
  • 35. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 6968 SPECIFICATIONS - OUTDOOR UNITS SPECIFICATIONS SPECIFICATIONS Model Name AM072FXVAFH/AA AM096FXVAFH/AA AM120FXVAFH/AA AM144FXVAFH/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Performance Ton TON 6.00 8.00 10.00 12.00 Capacity (Nominal) Cooling1) Btu/h 72,000 96,000 120,000 144,000 Heating1) Btu/h 81,000 108,000 135,000 162,000 Capacity (Rated) Cooling Btu/h 69,000 92,000 114,000 138,000 Heating Btu/h 77,000 103,000 129,000 154,000 Power MCA A 28 37.8 43 52.6 MOP A 35 50 50 70 Compressor Type - SSC Scroll x 1 SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2 Output kW × n (4.96) (4.96x2) (4.96x2) (4.96x2) Model Name - DS-GB052FBVASG x 1 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2 Oil Type - PVE PVE PVE PVE Initial Charge cc 1100 2200 2200 2200 fl. oz. 77.77 155.54 155.54 155.54 Fan Type - Propeller Propeller Propeller Propeller Output x n W 400 x 1 620 x 2 620 x 2 620 x 2 Air Flow Rate CFM 7,239.78 9,182.16 9,182.16 9,535.32 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 9.52 9.52 12.70 12.70 Ø, inch 3/8 3/8 1/2 1/2 Gas Pipe Ø, mm 19.05 22.22 28.58 28.58 Ø, inch 3/4 7/8 1 1/8 1 1/8 High Pressure Gas Pipe (for HR) Ø, mm - - - - Ø, inch - - - - Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 5.50 7.40 7.40 8.70 lbs 12.13 16.31 16.31 19.18 Sound2) Sound Pressure dB(A) 60.0 61.0 61.0 62.0 Sound Power 81 81 81 83 External Dimension Net Weight kg 190.0 278.0 278.0 293.0 lbs 418.88 612.89 612.89 645.95 Shipping Weight kg 206.0 300.0 300.0 312.0 lbs 454.15 661.39 661.39 687.84 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 inch 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 Shipping Dimensions (WxHxD) mm 948 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 inch 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement. DVM S HEAT PUMP (208~230V) Model Name AM168FXVAFH/AA AM192FXVAFH/AA AM216FXVAFH/AA AM240FXVAFH/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Performance Ton TON 14.00 16.00 18.00 20.00 Capacity (Nominal) Cooling1) Btu/h 168,000 192,000 216,000 240,000 Heating1) Btu/h 189,000 216,000 243,000 270,000 Capacity (Rated) Cooling Btu/h 161,000 183,000 207,000 228,000 Heating Btu/h 180,000 206,000 231,000 258,000 Power MCA A 65.8 71 80.6 86 MOP A 85 85 105 100 Compressor Type - SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 4 Output kW × n (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2)x2 Model Name - DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 4 Oil Type - PVE PVE PVE PVE Initial Charge cc 3300 3300 3300 4400 fl. oz. 233.32 233.32 233.32 311.09 Fan Type - Propeller Propeller Propeller Propeller Output x n W 620 x 2 + 400 x 1 620 x 2 + 400 x 1 620 x 2 + 400 x 1 (620 x 2) x 2 Air Flow Rate CFM 9,182.16 + 7,239.78 9,182.16 + 7,239.78 9,535.32 + 7,239.78 9,182.16 x 2 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 15.88 15.88 15.88 15.88 Ø, inch 5/8 5/8 5/8 5/8 Gas Pipe Ø, mm 28.58 28.58 28.58 28.58 Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8 High Pressure Gas Pipe (for HR) Ø, mm - - - - Ø, inch - - - - Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 12.90 12.90 14.20 14.80 lbs 28.44 28.44 31.31 32.63 Sound2) Sound Pressure dB(A) - - - - Sound Power - - - - External Dimension Net Weight kg 278.0 + 190.0 278.0 + 190.0 293.0 + 190.0 278.0 x 2 lbs 612.89 + 418.88 612.89 + 418.88 645.95 + 418.88 612.89 x 2 Shipping Weight kg 300.0 + 206.0 300.0 + 206.0 312.0 + 206.0 300.0 x 2 lbs 661.39 + 454.15 661.39 + 454.15 687.84 + 454.15 661.39 x 2 Net Dimensions (WxHxD) mm 1,295 x 1,695 x 765 + 880 x 1,695 x 765 1,295 x 1,695 x 765 + 880 x 1,695 x 765 1,295 x 1,695 x 765 + 880 x 1,695 x 765 (1,295 x 1,695 x 765) x 2 inch 50.98 x 66.73 x 30.12 + 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 + 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 + 34.65 x 66.73 x 30.12 (50.98 x 66.73 x 30.12) x 2 Shipping Dimensions (WxHxD) mm 1,363 x 1,912 x 832 + 948 x 1,912 x 832 1,363 x 1,912 x 832 + 948 x 1,912 x 832 1,363 x 1,912 x 832 + 948 x 1,912 x 832 (1,363 x 1,912 x 832) x 2 inch 53.66 x 75.28 x 32.76 + 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 + 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 + 37.32 x 75.28 x 32.76 (53.66 x 75.28 x 32.76) x 2 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement. DVM S HEAT PUMP (208~230V) OUTDOOR UNITS
  • 36. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 7170 SPECIFICATIONS - OUTDOOR UNITS SPECIFICATIONS SPECIFICATIONS DVM S HEAT PUMP (208~230V) DVM S HEAT PUMP (208~230V) OUTDOOR UNITS Model Name AM264FXVAFH/AA AM288FXVAFH/AA AM312FXVAFH/AA AM336FXVAFH/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Performance Ton TON 22.00 24.00 26.00 28.00 Capacity (Nominal) Cooling1) Btu/h 264,000 288,000 312,000 336,000 Heating1) Btu/h 297,000 324,000 351,000 378,000 Capacity (Rated) Cooling Btu/h 252,000 276,000 299,000 321,000 Heating Btu/h 283,000 308,000 334,000 360,000 Power MCA A 95.6 105.2 118.4 123.6 MOP A 120 140 155 155 Compressor Type - SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 5 SSC Scroll x 5 Output kW × n (4.96x2) + (4.96x2) (4.96x2)x2 (4.96x2) + (4.96x2) + (4.96) (4.96x2) + (4.96x2) + (4.96) Model Name - DS-GB052FBVASG x 4 DS-GB052FBVASG x 4 DS-GB052FBVASG x 5 DS-GB052FBVASG x 5 Oil Type - PVE PVE PVE PVE Initial Charge cc 4400 4400 5500 5500 fl. oz. 311.09 311.09 388.86 388.86 Fan Type - Propeller Propeller Propeller Propeller Output x n W (620 x 2) x 2 (620 x 2) x 2 (620 x 2) x 2 + 400 x 1 (620 x 2) x 2 + 400 x 1 Air Flow Rate CFM 9,182.16 + 9,535.32 9,535.32 x 2 9,182.16 + 9,535.32 + 7,239.78 9,182.16 + 9,535.32 + 7,239.78 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 19.05 19.05 19.05 19.05 Ø, inch 3/4 3/4 3/4 3/4 Gas Pipe Ø, mm 34.92 34.92 34.92 34.92 Ø, inch 1 3/8 1 3/8 1 3/8 1 3/8 High Pressure Gas Pipe (for HR) Ø, mm - - - - Ø, inch - - - - Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 16.10 17.40 21.60 21.60 lbs 35.49 38.36 47.62 47.62 Sound2) Sound Pressure dB(A) - - - - Sound Power - - - - External Dimension Net Weight kg 278.0 + 293.0 293.0 x 2 278.0 + 293.0 + 190.0 278.0 + 293.0 + 190.0 lbs 612.89 + 645.95 645.95 x 2 612.89 + 645.95 + 418.88 612.89 + 645.95 + 418.88 Shipping Weight kg 300.0 + 312.0 312.0 x 2 300.0 + 312.0 + 206.0 300.0 + 312.0 + 206.0 lbs 661.39 + 687.84 687.84 x 2 661.39 + 687.84 + 454.15 661.39 + 687.84 + 454.15 Net Dimensions (WxHxD) mm (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 + 880 x 1,695 x 765 (1,295 x 1,695 x 765) x 2 + 880 x 1,695 x 765 inch (50.98 x 66.73 x 30.12) x2 (50.98 x 66.73 x 30.12) x2 (50.98 x 66.73 x 30.12) x 2 + 34.65 x 66.73 x 30.12 (50.98 x 66.73 x 30.12) x 2 + 34.65 x 66.73 x 30.12 Shipping Dimensions (WxHxD) mm (1,363 x 1,912 x 832) x 2 (1,363 x 1,912 x 832) x 2 (1,363 x 1,912 x 832) x 2 + 948 x 1,912 x 832 (1,363 x 1,912 x 832) x 2 + 948 x 1,912 x 832 inch (53.66 x 75.28 x 32.76) x2 (53.66 x 75.28 x 32.76) x2 (53.66 x 75.28 x 32.76) x 2 + 37.32 x 75.28 x 32.76 (53.66 x 75.28 x 32.76) x 2 + 37.32 x 75.28 x 32.76 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement. Model Name AM360FXVAFH/AA AM384FXVAFH/AA AM408FXVAFH/AA AM432FXVAFH/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Performance Ton TON 30.00 32.00 34.00 36.00 Capacity (Nominal) Cooling1) Btu/h 360,000 384,000 408,000 432,000 Heating1) Btu/h 405,000 432,000 459,000 486,000 Capacity (Rated) Cooling Btu/h 345,000 366,000 390,000 414,000 Heating Btu/h 385,000 412,000 437,000 462,000 Power MCA A 133.2 138.6 148.2 157.8 MOP A 175 170 190 210 Compressor Type - SSC Scroll x 5 SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6 Output kW × n (4.96x2)x2 + (4.96) (4.96x2)x2 + (4.96x2) (4.96x2) + (4.96x2)x2 (4.96x2)x3 Model Name - DS-GB052FBVASG x 5 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6 Oil Type - PVE PVE PVE PVE Initial Charge cc 5500 6600 6600 6600 fl. oz. 388.86 466.63 466.63 466.63 Fan Type - Propeller Propeller Propeller Propeller Output x n W (620 x 2) x 2 + 400 x 1 (620 x 2) x 3 (620 x 2) x 3 (620 x 2) x 3 Air Flow Rate CFM 9,535.32 x 2 + 7,239.78 9,182.16 x 2 + 9,535.32 9,182.16 + 9,535.32 x 2 9,535.32 x 3 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 19.05 19.05 19.05 19.05 Ø, inch 3/4 3/4 3/4 3/4 Gas Pipe Ø, mm 41.28 41.28 41.28 41.28 Ø, inch 1 5/8 1 5/8 1 5/8 1 5/8 High Pressure Gas Pipe (for HR) Ø, mm - - - - Ø, inch - - - - Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 22.90 23.50 24.80 26.10 lbs 50.49 51.81 54.67 57.54 Sound2) Sound Pressure dB(A) - - - - Sound Power - - - - External Dimension Net Weight kg 293.0 x 2 + 190.0 278.0 x 2 + 293.0 278.0 + 293.0 x 2 293.0 x 3 lbs 645.95 x 2 + 418.88 612.89 x 2 + 645.95 612.89 + 645.95 x 2 645.95 x 3 Shipping Weight kg 312.0 x 2 + 206.0 300.0 x 2 + 312.0 300.0 + 312.0 x 2 312.0 x 3 lbs 687.84 x 2 + 454.15 661.39 x 2 + 687.84 661.39 + 687.84 x 2 687.84 x 3 Net Dimensions (WxHxD) mm (1,295 x 1,695 x 765) x 2 + 880 x 1,695 x 765 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 inch (50.98 x 66.73 x 30.12) x 2 + 34.65 x 66.73 x 30.12 (50.98 x 66.73 x 30.12) x 3 (50.98 x 66.73 x 30.12) x 3 (50.98 x 66.73 x 30.12) x 3 Shipping Dimensions (WxHxD) mm (1,363 x 1,912 x 832) x 2 + 948 x 1,912 x 832 (1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3 inch (53.66 x 75.28 x 32.76) x 2 + 37.32 x 75.28 x 32.76 (53.66 x 75.28 x 32.76) x 3 (53.66 x 75.28 x 32.76) x 3 (53.66 x 75.28 x 32.76) x 3 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement.
  • 37. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 7372 SPECIFICATIONS - OUTDOOR UNITS SPECIFICATIONS SPECIFICATIONS DVM S HEAT RECOVERY (208~230V) DVM S HEAT RECOVERY (208~230V) OUTDOOR UNITS Model Name AM072FXVAFR/AA AM096FXVAFR/AA AM120FXVAFR/AA AM144FXVAFR/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY Performance Ton TON 6.00 8.00 10.00 12.00 Capacity (Nominal) Cooling1) Btu/h 72,000 96,000 120,000 144,000 Heating1) Btu/h 81,000 108,000 135,000 162,000 Capacity (Rated) Cooling Btu/h 69,000 92,000 114,000 138,000 Heating Btu/h 77,000 103,000 129,000 154,000 Power MCA A 28 37.8 43 52.6 MOP A 35 50 50 70 Compressor Type - SSC Scroll x 1 SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2 Output kW × n (4.96) (4.96x2) (4.96x2) (4.96x2) Model Name - DS-GB052FBVASG x 1 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2 DS-GB052FBVASG x 2 Oil Type - PVE PVE PVE PVE Initial Charge cc 1100 2200 2200 2200 fl. oz. 77.77 155.54 155.54 155.54 Fan Type - Propeller Propeller Propeller Propeller Output x n W 400 x 1 620 x 2 620 x 2 620 x 2 Air Flow Rate CFM 7,239.78 9,182.16 9,182.16 9,535.32 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 9.52 9.52 12.70 12.70 Ø, inch 3/8 3/8 1/2 1/2 Gas Pipe Ø, mm 19.05 22.22 28.58 28.58 Ø, inch 3/4 7/8 1 1/8 1 1/8 High Pressure Gas Pipe (for HR) Ø, mm 15.88 19.05 22.22 22.22 Ø, inch 5/8 3/4 7/8 7/8 Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 5.50 7.40 7.40 8.70 lbs 12.13 16.31 16.31 19.18 Sound2) Sound Pressure dB(A) 60.0 61.0 61.0 62.0 Sound Power 81 81 81 83 External Dimension Net Weight kg 190.0 278.0 278.0 293.0 lbs 418.88 612.89 612.89 645.95 Shipping Weight kg 206.0 300.0 300.0 312.0 lbs 454.15 661.39 661.39 687.84 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 inch 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 Shipping Dimensions (WxHxD) mm 948 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 inch 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement. Model Name AM168FXVAFR/AA AM192FXVAFR/AA AM216FXVAFR/AA AM240FXVAFR/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY Performance Ton TON 14.00 16.00 18.00 20.00 Capacity (Nominal) Cooling1) Btu/h 168,000 192,000 216,000 240,000 Heating1) Btu/h 189,000 216,000 243,000 270,000 Capacity (Rated) Cooling Btu/h 161,000 183,000 207,000 228,000 Heating Btu/h 180,000 206,000 231,000 258,000 Power MCA A 65.8 71 80.6 86 MOP A 85 85 105 100 Compressor Type - SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 4 Output kW × n (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2) + (4.96) (4.96x2)x2 Model Name - DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 3 DS-GB052FBVASG x 4 Oil Type - PVE PVE PVE PVE Initial Charge cc 3300 3300 3300 4400 fl. oz. 233.32 233.32 233.32 311.09 Fan Type - Propeller Propeller Propeller Propeller Output x n W 620 x 2 + 400 x 1 620 x 2 + 400 x 1 620 x 2 + 400 x 1 (620 x 2) x 2 Air Flow Rate CFM 9,182.16 + 7,239.78 9,182.16 + 7,239.78 9,535.32 + 7,239.78 9,182.16 x 2 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 15.88 15.88 15.88 15.88 Ø, inch 5/8 5/8 5/8 5/8 Gas Pipe Ø, mm 28.58 28.58 28.58 28.58 Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8 High Pressure Gas Pipe (for HR) Ø, mm 22.22 28.58 28.58 28.58 Ø, inch 7/8 1 1/8 1 1/8 1 1/8 Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 12.90 12.90 14.20 14.80 lbs 28.44 28.44 31.31 32.63 Sound2) Sound Pressure dB(A) - - - - Sound Power - - - - External Dimension Net Weight kg 278.0 + 190.0 278.0 + 190.0 293.0 + 190.0 278.0 x 2 lbs 612.89 + 418.88 612.89 + 418.88 645.95 + 418.88 612.89 x 2 Shipping Weight kg 300.0 + 206.0 300.0 + 206.0 312.0 + 206.0 300.0 x 2 lbs 661.39 + 454.15 661.39 + 454.15 687.84 + 454.15 661.39 x 2 Net Dimensions (WxHxD) mm 1,295 x 1,695 x 765 + 880 x 1,695 x 765 1,295 x 1,695 x 765 + 880 x 1,695 x 765 1,295 x 1,695 x 765 + 880 x 1,695 x 765 (1,295 x 1,695 x 765) x 2 inch 50.98 x 66.73 x 30.12 + 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 + 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 + 34.65 x 66.73 x 30.12 (50.98 x 66.73 x 30.12) x 2 Shipping Dimensions (WxHxD) mm 1,363 x 1,912 x 832 + 948 x 1,912 x 832 1,363 x 1,912 x 832 + 948 x 1,912 x 832 1,363 x 1,912 x 832 + 948 x 1,912 x 832 (1,363 x 1,912 x 832) x 2 inch 53.66 x 75.28 x 32.76 + 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 + 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 + 37.32 x 75.28 x 32.76 (53.66 x 75.28 x 32.76) x 2 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement.
  • 38. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 7574 SPECIFICATIONS - OUTDOOR UNITS SPECIFICATIONS SPECIFICATIONS DVM S HEAT RECOVERY (208~230V) DVM S HEAT RECOVERY (208~230V) OUTDOOR UNITS Model Name AM264FXVAFR/AA AM288FXVAFR/AA AM312FXVAFR/AA AM336FXVAFR/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY Performance Ton TON 22.00 24.00 26.00 28.00 Capacity (Nominal) Cooling1) Btu/h 264,000 288,000 312,000 336,000 Heating1) Btu/h 297,000 324,000 351,000 378,000 Capacity (Rated) Cooling Btu/h 252,000 276,000 299,000 321,000 Heating Btu/h 283,000 308,000 334,000 360,000 Power MCA A 95.6 105.2 118.4 123.6 MOP A 120 140 155 155 Compressor Type - SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 5 SSC Scroll x 5 Output kW × n (4.96x2) + (4.96x2) (4.96x2)x2 (4.96x2) + (4.96x2) + (4.96) (4.96x2) + (4.96x2) + (4.96) Model Name - DS-GB052FBVASG x 4 DS-GB052FBVASG x 4 DS-GB052FBVASG x 5 DS-GB052FBVASG x 5 Oil Type - PVE PVE PVE PVE Initial Charge cc 4400 4400 5500 5500 fl. oz. 311.09 311.09 388.86 388.86 Fan Type - Propeller Propeller Propeller Propeller Output x n W (620 x 2) x 2 (620 x 2) x 2 (620 x 2) x 2 + 400 x 1 (620 x 2) x 2 + 400 x 1 Air Flow Rate CFM 9,182.16 + 9,535.32 9,535.32 x 2 9,182.16 + 9,535.32 + 7,239.78 9,182.16 + 9,535.32 + 7,239.78 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 19.05 19.05 19.05 19.05 Ø, inch 3/4 3/4 3/4 3/4 Gas Pipe Ø, mm 34.92 34.92 34.92 34.92 Ø, inch 1 3/8 1 3/8 1 3/8 1 3/8 High Pressure Gas Pipe (for HR) Ø, mm 28.58 28.58 28.58 28.58 Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8 Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 16.10 17.40 21.60 21.60 lbs 35.49 38.36 47.62 47.62 Sound2) Sound Pressure dB(A) - - - - Sound Power - - - - External Dimension Net Weight kg 278.0 + 293.0 293.0 x 2 278.0 + 293.0 + 190.0 278.0 + 293.0 + 190.0 lbs 612.89 + 645.95 645.95 x 2 612.89 + 645.95 + 418.88 612.89 + 645.95 + 418.88 Shipping Weight kg 300.0 + 312.0 312.0 x 2 300.0 + 312.0 + 206.0 300.0 + 312.0 + 206.0 lbs 661.39 + 687.84 687.84 x 2 661.39 + 687.84 + 454.15 661.39 + 687.84 + 454.15 Net Dimensions (WxHxD) mm (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 + 880 x 1,695 x 765 (1,295 x 1,695 x 765) x 2 + 880 x 1,695 x 765 inch (50.98 x 66.73 x 30.12) x 2 (50.98 x 66.73 x 30.12) x 2 (50.98 x 66.73 x 30.12) x 2 + 34.65 x 66.73 x 30.12 (50.98 x 66.73 x 30.12) x 2 + 34.65 x 66.73 x 30.12 Shipping Dimensions (WxHxD) mm (1,363 x 1,912 x 832) x 2 (1,363 x 1,912 x 832) x 2 (1,363 x 1,912 x 832) x 2 + 948 x 1,912 x 832 (1,363 x 1,912 x 832) x 2 + 948 x 1,912 x 832 inch (53.66 x 75.28 x 32.76) x 2 (53.66 x 75.28 x 32.76) x 2 (53.66 x 75.28 x 32.76) x 2 + 37.32 x 75.28 x 32.76 (53.66 x 75.28 x 32.76) x 2 + 37.32 x 75.28 x 32.76 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement. Model Name AM360FXVAFR/AA AM384FXVAFR/AA AM408FXVAFR/AA AM432FXVAFR/AA Power Supply Ø, V, Hz 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 3, 208-230, 60 Mode - HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY HEAT RECOVERY Performance Ton TON 30.00 32.00 34.00 36.00 Capacity (Nominal) Cooling1) Btu/h 360,000 384,000 408,000 432,000 Heating1) Btu/h 405,000 432,000 459,000 486,000 Capacity (Rated) Cooling Btu/h 345000 366000 390000 414000 Heating Btu/h 385000 412000 437000 462000 Power MCA A 133.2 138.6 148.2 157.8 MOP A 175 170 190 210 Compressor Type - SSC Scroll x 5 SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6 Output kW × n (4.96x2)x2 + (4.96) (4.96x2)x2 + (4.96x2) (4.96x2) + (4.96x2)x2 (4.96x2)x3 Model Name - DS-GB052FBVASG x 5 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6 DS-GB052FBVASG x 6 Oil Type - PVE PVE PVE PVE Initial Charge cc 5500 6600 6600 6600 fl. oz. 388.86 466.63 466.63 466.63 Fan Type - Propeller Propeller Propeller Propeller Output x n W (620 x 2) x 2 + 400 x 1 (620 x 2) x 3 (620 x 2) x 3 (620 x 2) x 3 Air Flow Rate CFM 9,535.32 x 2 + 7,239.78 9,182.16 x 2 + 9,535.32 9,182.16 + 9,535.32 x 2 9,535.32 x 3 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 19.05 19.05 19.05 19.05 Ø, inch 3/4 3/4 3/4 3/4 Gas Pipe Ø, mm 41.28 41.28 41.28 41.28 Ø, inch 1 5/8 1 5/8 1 5/8 1 5/8 High Pressure Gas Pipe (for HR) Ø, mm 34.92 34.92 34.92 34.92 Ø, inch 1 3/8 1 3/8 1 3/8 1 3/8 Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 22.90 23.50 24.80 26.10 lbs 50.49 51.81 54.67 57.54 Sound2) Sound Pressure dB(A) - - - - Sound Power - - - - External Dimension Net Weight kg 293.0 x 2 + 190.0 278.0 x 2 + 293.0 278.0 + 293.0 x 2 293.0 x 3 lbs 645.95 x 2 + 418.88 612.89 x 2 + 645.95 612.89 + 645.95 x 2 645.95 x 3 Shipping Weight kg 312.0 x 2 + 206.0 300.0 x 2 + 312.0 300.0 + 312.0 x 2 312.0 x 3 lbs 687.84 x 2 + 454.15 661.39 x 2 + 687.84 661.39 + 687.84 x 2 687.84 x 3 Net Dimensions (WxHxD) mm (1,295 x 1,695 x 765) x 2 + 880 x 1,695 x 765 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 inch (50.98 x 66.73 x 30.12) x 2 + 34.65 x 66.73 x 30.12 (50.98 x 66.73 x 30.12) x 3 (50.98 x 66.73 x 30.12) x 3 (50.98 x 66.73 x 30.12) x 3 Shipping Dimensions (WxHxD) mm (1,363 x 1,912 x 832) x 2 + 948 x 1,912 x 832 (1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3 (1,363 x 1,912 x 832) x 3 inch (53.66 x 75.28 x 32.76) x 2 + 37.32 x 75.28 x 32.76 (53.66 x 75.28 x 32.76) x 3 (53.66 x 75.28 x 32.76) x 3 (53.66 x 75.28 x 32.76) x 3 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement.
  • 39. SAMSUNG VRF SYSTEM - DVM S SAMSUNG VRF SYSTEM - DVM S 7776 SPECIFICATIONS - OUTDOOR UNITS SPECIFICATIONS SPECIFICATIONS DVM S HEAT PUMP (460V) DVM S HEAT PUMP (460V) OUTDOOR UNITS Model Name AM072FXVAJH/AA AM096FXVAJH/AA AM120FXVAJH/AA AM144FXVAJH/AA Power Supply Ø, V, Hz 3, 460, 60 3, 460, 60 3, 460, 60 3, 460, 60 Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Performance Ton TON 6.00 8.00 10.00 12.00 Capacity (Nominal) Cooling1) Btu/h 72,000 92,000 120,000 144,000 Heating1) Btu/h 81,000 108,000 135,000 162,000 Capacity (Rated) Cooling Btu/h 69,000 92,000 114,000 138,000 Heating Btu/h 77,000 103,000 129,000 154,000 Power MCA A 16.4 19 21.7 26.4 MOP A 20 25 30 40 Compressor Type - SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 2 Output kW × n (4.96) (6.13) (6.13) (4.96x2) Model Name - DS-GB052FAVASG x 1 DS-GB066FAVASG x 1 DS-GB066FAVASG x 1 DS-GB052FAVASG x 2 Oil Type - PVE PVE PVE PVE Initial Charge cc 1100 1100 1100 2200 fl. oz. 77.77 77.77 77.77 155.54 Fan Type - Propeller Propeller Propeller Propeller Output x n W 400 x 1 620 x 2 620 x 2 620 x 2 Air Flow Rate CFM 7,239.78 9,182.16 9,182.16 9,535.32 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 9.52 9.52 12.70 12.70 Ø, inch 3/8 3/8 1/2 1/2 Gas Pipe Ø, mm 19.05 22.22 28.58 28.58 Ø, inch 3/4 7/8 1 1/8 1 1/8 High Pressure Gas Pipe (for HR) Ø, mm - - - - Ø, inch - - - - Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 5.50 7.40 7.40 8.70 lbs 12.13 16.31 16.31 19.18 Sound2) Sound Pressure dB(A) 60.0 61.0 61.0 62.0 Sound Power 81 81 81 83 External Dimension Net Weight kg 190.0 278.0 278.0 293.0 lbs 418.88 612.89 612.89 645.95 Shipping Weight kg 206.0 300.0 300.0 312.0 lbs 454.15 661.39 661.39 687.84 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 inch 34.65 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 50.98 x 66.73 x 30.12 Shipping Dimensions (WxHxD) mm 948 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 1,363 x 1,912 x 832 inch 37.32 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 53.66 x 75.28 x 32.76 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement. Model Name AM168FXVAJH/AA AM192FXVAJH/AA AM216FXVAJH/AA AM240FXVAJH/AA Power Supply Ø, V, Hz 3, 460, 60 3, 460, 60 3, 460, 60 3, 460, 60 Mode - HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Performance Ton TON 13.67 16.00 18.00 20.00 Capacity (Nominal) Cooling1) Btu/h 164,000 192,000 216,000 240,000 Heating1) Btu/h 189,000 216,000 243,000 270,000 Capacity (Rated) Cooling Btu/h 161000 183000 207000 228000 Heating Btu/h 180000 206000 231000 258000 Power MCA A 35.4 38.1 42.8 43.4 MOP A 60 50 60 60 Compressor Type - SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 3 SSC Scroll x 2 Output kW × n (4.96) + (6.13) (4.96) + (6.13) (4.96) + (4.96x2) (6.13)x2 Model Name - DS-GB052FAVASG x 1 + DS-GB066FAVASG x 1 DS-GB052FAVASG x 1 + DS-GB066FAVASG x 1 DS-GB052FAVASG x 3 DS-GB066FAVASG x 2 Oil Type - PVE PVE PVE PVE Initial Charge cc 2200 2200 3300 2200 fl. oz. 155.54 155.54 233.32 155.54 Fan Type - Propeller Propeller Propeller Propeller Output x n W 400 x 1 + 620 x 2 400 x 1 + 620 x 2 400 x 1 + 620 x 2 (620 x 2) x 2 Air Flow Rate CFM 7,239.78 + 9,182.16 7,239.78 + 9,182.16 7,239.78 + 9,535.32 9,182.16 x 2 External Static Pressure Max. mmAq 8.00 8.00 8.00 8.00 In Wg 0.31 0.31 0.31 0.31 Piping Connections Liquid Pipe Ø, mm 15.88 15.88 15.88 15.88 Ø, inch 5/8 5/8 5/8 5/8 Gas Pipe Ø, mm 28.58 28.58 28.58 28.58 Ø, inch 1 1/8 1 1/8 1 1/8 1 1/8 High Pressure Gas Pipe (for HR) Ø, mm - - - - Ø, inch - - - - Installation Limitation Max. Length m 200(220) 200(220) 200(220) 200(220) ft 656(722) 656(722) 656(722) 656(722) Max. Height m 110(40) 110(40) 110(40) 110(40) ft 361(131) 361(131) 361(131) 361(131) Refrigerant Type - R410A R410A R410A R410A Factory Charging kg 12.90 12.90 14.20 14.80 lbs 28.44 28.44 31.31 32.63 Sound2) Sound Pressure dB(A) - - - - Sound Power - - - - External Dimension Net Weight kg 190.0 + 278.0 190.0 + 278.0 190.0 + 293.0 278.0 x 2 lbs 418.88 + 612.89 418.88 + 612.89 418.88 + 645.95 612.89 x 2 Shipping Weight kg 206.0 + 300.0 206.0 + 300.0 206.0 + 312.0 300.0 x 2 lbs 454.15 + 661.39 454.15 + 661.39 454.15 + 687.84 661.39 x 2 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 + 1,295 x 1,695 x 765 880 x 1,695 x 765 + 1,295 x 1,695 x 765 880 x 1,695 x 765 + 1,295 x 1,695 x 765 (1,295 x 1,695 x 765) x 2 inch 34.65 x 66.73 x 30.12 + 50.98 x 66.73 x 30.12 34.65 x 66.73 x 30.12 + 50.98 x 66.73 x 30.12 34.65 x 66.73 x 30.12 + 50.98 x 66.73 x 30.12 (50.98 x 66.73 x 30.12) x 2 Shipping Dimensions (WxHxD) mm 948 x 1,912 x 832 + 1,363 x 1,912 x 832 948 x 1,912 x 832 + 1,363 x 1,912 x 832 948 x 1,912 x 832 + 1,363 x 1,912 x 832 (1,363 x 1,912 x 832) x 2 inch 37.32 x 75.28 x 32.76 + 53.66 x 75.28 x 32.76 37.32 x 75.28 x 32.76 + 53.66 x 75.28 x 32.76 37.32 x 75.28 x 32.76 + 53.66 x 75.28 x 32.76 (53.66 x 75.28 x 32.76) x 2 Operating Temp. Range Cooling °F 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 23.0 ~ 120.0 Heating °F -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 -4.0 ~ 75.0 1) Nominal Capacity is based on (Equivalent refrigerant piping : 25ft , Level differences : 0ft); - Cooling : Indoor temperature : 80°F DB, 67°F WB / Outdoor temperature : 95°F DB, 75°F WB - Heating : Indoor temperature : 70°F DB, 60°F WB / Outdoor temperature : 47°F DB, 43°F WB 2) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. 3) Specifications are subject to change without prior notice for product improvement.