Electric cars are automobiles, which are powered by the electric engine and electric energy. The development of the electric vehicles is a very perspective and important process. Scientists and engineers managed to create electric engines which are no less effective than the ordinary engines used today. It is obvious that electric cars are more ecologically safe and require less energy for work. EVs provide fast acceleration by delivering power instantly to the wheels by providing high torque at low speeds; they give a feel of smooth and quick responsiveness (Technology).
Electric cars are automobiles, which are powered by the electric engine and electric energy. The development of the electric vehicles is a very perspective and important process. Scientists and engineers managed to create electric engines which are no less effective than the ordinary engines used today. It is obvious that electric cars are more ecologically safe and require less energy for work. EVs provide fast acceleration by delivering power instantly to the wheels by providing high torque at low speeds; they give a feel of smooth and quick responsiveness (Technology).
New technologies and new features and functionalities will make automotive lighting a $27.7 billion market by 2021 (and an exciting one at that)!
AUTOMOTIVE LIGHTING IS GROWING FAST ($27.7B IN 2021) BY INCREASING ITS DESIGN USES AND PROVIDING NEW FUNCTIONALITIES
With the recent integration of LED technology, lighting has evolved from a basic, functional feature to a distinctive feature with high-value potential in automotive. Indeed, LED technology has given manufacturers the opportunity for strong differentiation via lighting design and additional functionalities. This is particularly true for exterior lighting, but it is also spreading to interior lighting. These changes are heavily impacting the supply chain, with new suppliers and a new value chain emerging.
In 2015, the automotive lighting market totaled nearly $22.4B, up 5.4% from 2014. This growth was driven by increased lighting system content per vehicle and a more favorable product mix driven by strong adoption of LED-based front lighting systems. Indeed, headlamp and Day Running Light (DRL) systems represented 43% and 28% of total 2015 revenue, respectively. Other lighting systems (i.e. Rear Combination Light/Center High-Mounted Signal Light, interior light, and side turn-signal light) comprised the remaining 29% of 2015 revenue. The automotive lighting market will continue growing, reaching a market size of almost $27.7B by 2021 - +23.7% compared to 2015, and driven by different growth areas:
Short-term: increased LED technology penetration rate into different automotive lighting applications/systems, and increased lighting content per vehicle.
Middle/long-term: potential integration of new lighting technologies like OLED and laser, development of Advanced Front Lighting Systems (AFLS) and other security functions, and incredible developments employing lighting as a new design feature.
This report presents all automotive lighting applications and the associated market revenue for the period 2013 - 2021, with details concerning drivers and challenges, integration status of different lighting technologies and systems, recent trends, and market size per application.
We started with various kind of frictional forces which are projected to bicycle during the run. Then after we calculate approx motor power t which needed to drive the bicycle. We used BLDC motor as a hub drive and connect it in the front wheel of the bicycle. We use lithium-ion battery cells and by connecting them in series-parallel, we made a 36V, 13.2 Ah battery pack. We also connect BMS(Battery Management System) which protects the battery pack from over-charging and over-discharging kind of faults. Top speed of the bicycle is 35kmph and the distance traveled on a single charge is up to 35 to 40km.
Process of converting solar thermal energy (heat) into conditioned air.
ďąEco-friendly as well as Energy-efficient.
ďąCan be operated with green resources of heat as backup resources when solar radiation is unavailable
New technologies and new features and functionalities will make automotive lighting a $27.7 billion market by 2021 (and an exciting one at that)!
AUTOMOTIVE LIGHTING IS GROWING FAST ($27.7B IN 2021) BY INCREASING ITS DESIGN USES AND PROVIDING NEW FUNCTIONALITIES
With the recent integration of LED technology, lighting has evolved from a basic, functional feature to a distinctive feature with high-value potential in automotive. Indeed, LED technology has given manufacturers the opportunity for strong differentiation via lighting design and additional functionalities. This is particularly true for exterior lighting, but it is also spreading to interior lighting. These changes are heavily impacting the supply chain, with new suppliers and a new value chain emerging.
In 2015, the automotive lighting market totaled nearly $22.4B, up 5.4% from 2014. This growth was driven by increased lighting system content per vehicle and a more favorable product mix driven by strong adoption of LED-based front lighting systems. Indeed, headlamp and Day Running Light (DRL) systems represented 43% and 28% of total 2015 revenue, respectively. Other lighting systems (i.e. Rear Combination Light/Center High-Mounted Signal Light, interior light, and side turn-signal light) comprised the remaining 29% of 2015 revenue. The automotive lighting market will continue growing, reaching a market size of almost $27.7B by 2021 - +23.7% compared to 2015, and driven by different growth areas:
Short-term: increased LED technology penetration rate into different automotive lighting applications/systems, and increased lighting content per vehicle.
Middle/long-term: potential integration of new lighting technologies like OLED and laser, development of Advanced Front Lighting Systems (AFLS) and other security functions, and incredible developments employing lighting as a new design feature.
This report presents all automotive lighting applications and the associated market revenue for the period 2013 - 2021, with details concerning drivers and challenges, integration status of different lighting technologies and systems, recent trends, and market size per application.
We started with various kind of frictional forces which are projected to bicycle during the run. Then after we calculate approx motor power t which needed to drive the bicycle. We used BLDC motor as a hub drive and connect it in the front wheel of the bicycle. We use lithium-ion battery cells and by connecting them in series-parallel, we made a 36V, 13.2 Ah battery pack. We also connect BMS(Battery Management System) which protects the battery pack from over-charging and over-discharging kind of faults. Top speed of the bicycle is 35kmph and the distance traveled on a single charge is up to 35 to 40km.
Process of converting solar thermal energy (heat) into conditioned air.
ďąEco-friendly as well as Energy-efficient.
ďąCan be operated with green resources of heat as backup resources when solar radiation is unavailable
The new Carrier Inverter Ducted Air Conditioner
combines the ease of installation of Ducted Air
Conditioners and the performance of 1:1 VRF units
to provide effective cooling without compromise
Four-way air distribution gives individual comfort while for localized control each diffuser may be adjusted or even shut down completely.
The unique design of centrifugal fan ensures the quiet running of the unit. This thoroughly eliminates the bothering throttle noise inside the room.
Dekon , onf of the professional supplier and exporter for VRF system in China. Have exported to more than 30 different countries our products. Dekon vrf system brief introduction here just brief intro of our products DRV, any more info needed, pls visit us at dekon-china.com or chinavrf.com
YORKŽ AMICHI⢠Series Air-Cooled DC Inverter Scroll Chillers and Heat PumpsIlia Iovtchev
Â
Mundus Services, the official partner and service provider for Johnson Controls products and services in Bulgaria, is now ready to deliver technical solutions to our clients based on the highly efficient YorkÂŽ AmichiTM series of air-cooled DC inverter scroll chillers and heat pumps, designed to meet tomorrowâs efficiency standards today.
Delivering performance far beyond the typical chiller and heat pump efficiency levels, the YORKŽ Amichi⢠Series meets or exceeds stringent European regulatory requirements through an optimized combination of YORKŽ efficiency enhancing technologies.
Putting the SPARK into Virtual Training.pptxCynthia Clay
Â
This 60-minute webinar, sponsored by Adobe, was delivered for the Training Mag Network. It explored the five elements of SPARK: Storytelling, Purpose, Action, Relationships, and Kudos. Knowing how to tell a well-structured story is key to building long-term memory. Stating a clear purpose that doesn't take away from the discovery learning process is critical. Ensuring that people move from theory to practical application is imperative. Creating strong social learning is the key to commitment and engagement. Validating and affirming participants' comments is the way to create a positive learning environment.
Personal Brand Statement:
As an Army veteran dedicated to lifelong learning, I bring a disciplined, strategic mindset to my pursuits. I am constantly expanding my knowledge to innovate and lead effectively. My journey is driven by a commitment to excellence, and to make a meaningful impact in the world.
What are the main advantages of using HR recruiter services.pdfHumanResourceDimensi1
Â
HR recruiter services offer top talents to companies according to their specific needs. They handle all recruitment tasks from job posting to onboarding and help companies concentrate on their business growth. With their expertise and years of experience, they streamline the hiring process and save time and resources for the company.
RMD24 | Debunking the non-endemic revenue myth Marvin Vacquier Droop | First ...BBPMedia1
Â
Marvin neemt je in deze presentatie mee in de voordelen van non-endemic advertising op retail media netwerken. Hij brengt ook de uitdagingen in beeld die de markt op dit moment heeft op het gebied van retail media voor niet-leveranciers.
Retail media wordt gezien als het nieuwe advertising-medium en ook mediabureaus richten massaal retail media-afdelingen op. Merken die niet in de betreffende winkel liggen staan ook nog niet in de rij om op de retail media netwerken te adverteren. Marvin belicht de uitdagingen die er zijn om echt aansluiting te vinden op die markt van non-endemic advertising.
Memorandum Of Association Constitution of Company.pptseri bangash
Â
www.seribangash.com
A Memorandum of Association (MOA) is a legal document that outlines the fundamental principles and objectives upon which a company operates. It serves as the company's charter or constitution and defines the scope of its activities. Here's a detailed note on the MOA:
Contents of Memorandum of Association:
Name Clause: This clause states the name of the company, which should end with words like "Limited" or "Ltd." for a public limited company and "Private Limited" or "Pvt. Ltd." for a private limited company.
https://seribangash.com/article-of-association-is-legal-doc-of-company/
Registered Office Clause: It specifies the location where the company's registered office is situated. This office is where all official communications and notices are sent.
Objective Clause: This clause delineates the main objectives for which the company is formed. It's important to define these objectives clearly, as the company cannot undertake activities beyond those mentioned in this clause.
www.seribangash.com
Liability Clause: It outlines the extent of liability of the company's members. In the case of companies limited by shares, the liability of members is limited to the amount unpaid on their shares. For companies limited by guarantee, members' liability is limited to the amount they undertake to contribute if the company is wound up.
https://seribangash.com/promotors-is-person-conceived-formation-company/
Capital Clause: This clause specifies the authorized capital of the company, i.e., the maximum amount of share capital the company is authorized to issue. It also mentions the division of this capital into shares and their respective nominal value.
Association Clause: It simply states that the subscribers wish to form a company and agree to become members of it, in accordance with the terms of the MOA.
Importance of Memorandum of Association:
Legal Requirement: The MOA is a legal requirement for the formation of a company. It must be filed with the Registrar of Companies during the incorporation process.
Constitutional Document: It serves as the company's constitutional document, defining its scope, powers, and limitations.
Protection of Members: It protects the interests of the company's members by clearly defining the objectives and limiting their liability.
External Communication: It provides clarity to external parties, such as investors, creditors, and regulatory authorities, regarding the company's objectives and powers.
https://seribangash.com/difference-public-and-private-company-law/
Binding Authority: The company and its members are bound by the provisions of the MOA. Any action taken beyond its scope may be considered ultra vires (beyond the powers) of the company and therefore void.
Amendment of MOA:
While the MOA lays down the company's fundamental principles, it is not entirely immutable. It can be amended, but only under specific circumstances and in compliance with legal procedures. Amendments typically require shareholder
Cracking the Workplace Discipline Code Main.pptxWorkforce Group
Â
Cultivating and maintaining discipline within teams is a critical differentiator for successful organisations.
Forward-thinking leaders and business managers understand the impact that discipline has on organisational success. A disciplined workforce operates with clarity, focus, and a shared understanding of expectations, ultimately driving better results, optimising productivity, and facilitating seamless collaboration.
Although discipline is not a one-size-fits-all approach, it can help create a work environment that encourages personal growth and accountability rather than solely relying on punitive measures.
In this deck, you will learn the significance of workplace discipline for organisational success. Youâll also learn
⢠Four (4) workplace discipline methods you should consider
⢠The best and most practical approach to implementing workplace discipline.
⢠Three (3) key tips to maintain a disciplined workplace.
Digital Transformation and IT Strategy Toolkit and TemplatesAurelien Domont, MBA
Â
This Digital Transformation and IT Strategy Toolkit was created by ex-McKinsey, Deloitte and BCG Management Consultants, after more than 5,000 hours of work. It is considered the world's best & most comprehensive Digital Transformation and IT Strategy Toolkit. It includes all the Frameworks, Best Practices & Templates required to successfully undertake the Digital Transformation of your organization and define a robust IT Strategy.
Editable Toolkit to help you reuse our content: 700 Powerpoint slides | 35 Excel sheets | 84 minutes of Video training
This PowerPoint presentation is only a small preview of our Toolkits. For more details, visit www.domontconsulting.com
What is the TDS Return Filing Due Date for FY 2024-25.pdfseoforlegalpillers
Â
It is crucial for the taxpayers to understand about the TDS Return Filing Due Date, so that they can fulfill your TDS obligations efficiently. Taxpayers can avoid penalties by sticking to the deadlines and by accurate filing of TDS. Timely filing of TDS will make sure about the availability of tax credits. You can also seek the professional guidance of experts like Legal Pillers for timely filing of the TDS Return.
Tata Group Dials Taiwan for Its Chipmaking Ambition in Gujaratâs DholeraAvirahi City Dholera
Â
The Tata Group, a titan of Indian industry, is making waves with its advanced talks with Taiwanese chipmakers Powerchip Semiconductor Manufacturing Corporation (PSMC) and UMC Group. The goal? Establishing a cutting-edge semiconductor fabrication unit (fab) in Dholera, Gujarat. This isnât just any project; itâs a potential game changer for Indiaâs chipmaking aspirations and a boon for investors seeking promising residential projects in dholera sir.
Visit : https://www.avirahi.com/blog/tata-group-dials-taiwan-for-its-chipmaking-ambition-in-gujarats-dholera/
LA HUG - Video Testimonials with Chynna Morgan - June 2024Lital Barkan
Â
Have you ever heard that user-generated content or video testimonials can take your brand to the next level? We will explore how you can effectively use video testimonials to leverage and boost your sales, content strategy, and increase your CRM data.đ¤Ż
We will dig deeper into:
1. How to capture video testimonials that convert from your audience đĽ
2. How to leverage your testimonials to boost your sales đ˛
3. How you can capture more CRM data to understand your audience better through video testimonials. đ
2. Digital InverterDI
Toshiba solutions
Toshiba offers a solution for all applications: residential, light commercial and larger
commercial buildings. For small commercial premises, products are designed to
deliver top performance combined with energy efficiency.
Toshibaâs commitment to society drives a company-wide focus on attention to the
details through every stage of the development process, from design to user field
tests. Installations using our products and systems therefore feature a higher standard
of indoor air quality, sound levels, energy savings, and environmental awareness.
Superior comfort
Toshiba can help you create a comfortable space while
also caring for the environment.
3. 3
Very efficient energy consumption, Keeps
down operating costs.
Superior EER
ECO-driving DC twin rotary compressor
Vector-controlled inverter
High efficiency heat-transfer (flat fin)
DC fan motor
Bat wing fan
Wide-flow grille
DC twin rotary compressor
Vector IPDU control changes the motor
current wave to a smooth sine pattern
so that noise emitted from the drive
units is greatly reduced.
Heat-transfer tube with improved heat-transfer
coefficient.
Highly Efficient DC Motor.
New development for high-pressure
low-volume fan.
Optimizing ventilation performance,
Bringing out the full effect of fan and motor.
A low minimum speed of 10 rps has been
achieved.
Light Commercial
The Toshiba Digital Inverter series air conditioners combine economy and ecology in a compact body. They feature state-
of-the-art technology, flexible control, and easy installation to bring natural comfort and convenience to any business
environment. Consists of Cassette and Ducted units which has excellent efficiency, not only under rated EER conditions,
but also during partial load which is the larger part of actual operating conditions.
A low minimum speed of 10 rps has been achieved.
This has further improved the operating
efficiency when the load is low
(the minimum in Series 2 was 15 rps).
Large-area magnet
Rotor with slit
High power motor
Newly designed compression path
More precise components
The structure and shape of each
compressor component has been
optimised. The area of the rotor
magnet has been increased and
a slit introduced to the design.
These improvements have further
enhanced efficiency and reduced
noise.
Operation in Power Save Mode enables power peaks to be cut.
2 HP 5 HP4 HP3 HP
3.02
3.31
2.80
5.0
4.0
3.0
2.0
1.0
0.0
(EER)
3.21
Digital Inverter / New 4-Way Cassette
Note: Actual component may vary considerably from specifications depending on product model.
4. An ozone layer depletion coefficient of zero has become
absolutely essential for an advanced air conditioning system.
R410A refrigerant
Fits with various size room and form
- Combination : Same type and capacity of indoor units
- Twin kit Line up
Twin split System
Quiet operation
Low-noise design. If the outdoor temperature is 30°C or less, operates at under 45 db. Itâs possible to
automatically operate the quiet operation mode below 35°C air temperature.
Self-Clean operation-Continuing high performance for energy saving
This enables the 4-Way Cassette type to maintain energy efficiency.
Water
Oil/
Aqua
resin
coating
Dirt
Self-Clean Operation - The mechanism of the wash-off
1. The aqua resin coating prevents dirt from sticking to
the fins.
2. The condensation water flows and washes away dirt.
3. After washing, a drying operation suppresses the
propagation of mold.
4
5. Digital InverterDI
Extremely lightweight and compact outdoor unit
Lighter than the current model by 8 kg (11%)
4 HP
5 HP
1104ATP-E
1404ATP-E
-8kg68kg
previous model:76kg
Small compact size chassis
Reduces installation spaces and enables a more efficient use of the site.
Easy to install the outdoor units on a double-decked and easy to install on a wall.
Current model
New model
Wide-Utility function
Heating operation is possible starting from an outdoor temperature of -20°C, while cooling operation is
possible at -15°C and up to 46 outdoor temperature. This enables wider applications and use of the system
in colder regions.
Outstandingly quiet operation & save operation setting
Night operation make it possible to suppress the operation sound of the
outdoor unit within the time which you desire. (12dB(A) reduction)*
Easy and safty operation for maintenance of the outdoor unit.
Inspection window makes it easy to find switch that requires operation and reduces the risk of electrical shock.
Remarkable energy efficiency
Industryâs top-class energy-saving
2,3 HP 4,5 HP
(Max.10%UP)
Cover
Inspection window
Maintenance Switch (2 tact switches)
Maintenance light (6LED)
Save operation setting is available from 50% to 100% by 1%
Quiet operation & save operation setting available for 2HP, 3HP, 4HP and 5HP
*5HP Outdoor unit, Heating.
Note: Night operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E)
Save operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E), RBC-AMT32E
55
6. DIBIG
DI Big proposes competitive cost systems solution for medium size applications like Shops and Small Office buildings.
Simultaneous operation of 2, 3 or up to 4 indoor unit can be installed as twin, triple and double twin systems with
single outdoor unit.
Compact outdoor unit
Small footprint in only 0.29 m2, Compact design in size (W 900mmx D 320mm) allows opportunity for
more space saving.
High efficiency EER/COP* performance
DI Big is equipped with a new twin-rotary DC inverter compressor with high efficiency R410A refrigerant.
A new technology twin-rotary DC compressor, 100W +100W output Highly-efficient DC fan motor,
propeller fan for newly developed 3-row heat exchanger.
EER / COP = 2.81 / 3.61 ( With 4-way cassette twin system of 10HP)
Wider discharge port for less pressure loss
Screw connection for larger current
Decreasing oil discharge for reliability
Larger displacement cylinder (55cm3/rev)
Expanded operating temperature range
Air conditioning system designing is easy with DI-BIG because of its expanded operation range.
Heater operation is possible starting from an outdoor temperature of -20°C, while cooling operation
is possible at -15°C and up to 46 outdoor temperature.
This enables wider applications and use of the system in colder regions.
DI BIG
Outdoor temp. range when cooling* -15ËC to 46ËC
Outdoor temp. range when heating* -20ËC to 15ËC
Heating operation range
15ËC0ËC-15ËC-20ËC
*Cooling : ËCDB, Heating: ËCWB
DI BIGDI BIG
Compatible with pipes up to 70 meters long with
a maximum height difference of 30 meters height
6
7. Equivalent HP 2HP 3HP 4HP 5HP 6HP
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
4-Way Cassette type
Single (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E N/A
Twin (RAV-) N/A N/A SM564UTP-E x 2 SM804UTP-E x 2 SM804UTP-E x 2
Triple (RAV-) N/A N/A N/A N/A SM564UTP-E x 3
Standard Duct type
Single (RAV-) SM566BTP-E* SM806BTP-E* SM1106BTP-E* SM1406BTP-E* N/A
Twin (RAV-) N/A N/A SM566BTP-E* x 2 SM806BTP-E* x 2 SM806BTP-E* x 2
Triple (RAV-) N/A N/A N/A N/A SM566BTP-E* x 3
Concealed Duct High Static Pressure type
Single (RAV-) N/A N/A N/A N/A SM1603DT-A
Twin (RAV-) N/A N/A N/A N/A N/A
Triple (RAV-) N/A N/A N/A N/A N/A
Digital Inverter 1-phase model
*1 Rated conditions Cooling : Indoor air temperature 27o
C DB / 19o
C WB, Outdoor air temperature 35o
C DB
Heating : Indoor air temperature 20o
C DB, Outdoor air temperature 7o
C DB / 6o
C WB
*2 Sound pressure levels measured in an anechoic chamber
77
8. Equivalent HP 10HP
50Hz
Standard model (RAV-) SM2804AT8-E
Heavy Anti-Corrosion protection model (RAV-) SM2804AT8ZG-E
4-Way Cassette type
Single (RAV-) N/A
Twin (RAV-) SM1404UTP-E x 2
Triple (RAV-) SM804UTP-E x 3
Double twin
(RAV-)
SM804UTP-E x 4
Standard Duct type
Single (RAV-) N/A
Twin (RAV-) SM1406BTP-E* x 2
Triple (RAV-) SM806BTP-E* x 3
Double twin
(RAV-)
SM806BTP-E* x 4
Concealed Duct High Static Pressure type
Single (RAV-) SM2802DT-E
Twin (RAV-) N/A
Triple (RAV-) N/A
Double twin
(RAV-)
N/A
Digital Inverter Big 3-phase model
*1 Rated conditions Cooling : Indoor air temperature 27o
C DB / 19o
C WB, Outdoor air temperature 35o
C DB
Heating : Indoor air temperature 20o
C DB, Outdoor air temperature 7o
C DB / 6o
C WB
*2 Sound pressure levels measured in an anechoic chamber
8
9. rAV-SMâââ4UTP-E
4-Way Cassette type
RBC-U31PGP(W)-E
The wide air flow in all direction
Multi-louver individual control
Individual louver control enables airflow to be chosen according to user preferences.
The angles of each louver can be set individually in 3 different choices of swing
patterns; Standard swing, Diagonally opposite swing and Turn-around swing
(1) Standard swing (2) Diagonally opposite swing (3) Turn-around swing
New Long-life pre-filter
A new long-life pre-filter has a surface 1.5 times of current filters to improve Dust-collection performance.
Built-in condensate drain pump Easy installation
Light weight unit (24kg at 5HP) Easy panel
installation, The panel is attached using the
bolt that is already installed on the indoor unit.
300mm or less
850mm or less
210mm
Panel
Wide flow louver type
4-Way Cassette type
Digital Inverter
.
Comfort
Inverter
Allows step-less regulation of the
air-conditionerâs power,which reduces
energy consumption and improves
comfort.
.
Individual Louvre control
Enables airflows to be chosen
according to user preferences.
.
Hot Start
When using the heater for preheating
or defrosting, stops the indoor fan to
prevent cold air from being blown into
the room.
Dry
Gradually dehumidifies the room to
create even greater comfort.
Operativity
Filter Sign
Automatic displays on the remote
controller say when to perform
maintenance for the indoor unit filter.
Limit Timer
Uses a 168-hour timer with three
modes - âON timerâ, âOFF timerâ and
âRepeat OFF timerâ.
Installation
Cooler Compatible with an Outdoor
Temperature of -15 ° C
Stable cooler operation is possible
when the outdoor temperature is as
low as -15 ° C.
Built-in Drain Pump
The built-in drain pump makes
draining easier. (In the ceiling cassette
type, it is built in to the main unit.)
Long-life Filter
Built-in long-life filter makes
maintenance easier.
Automatic Air Volume control
Depending on the difference between
the room temperature and the set
temperature, switches automatically
between High, Low and Very Low.
Auto-turn Louvre
Air outlet grilles move automatically
to fill every corner of the room with
warm or cool air.
*European market only
99
10. Physical data Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E
Standard air flow (H/M/L) CFM 617/512/459 723/564/476 1182/847/688 1235/847/723
Sound pressure level (H/M/L) dB(A) 32/29/28 35/31/28 43/38/33 44/38/34
Main unit dimensions (H/W/D) mm 256/840/840 256/840/840 319/840/840 319/840/840
Weightkg 20 20 24 24
Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950
Panel weight kg 4.2 4.2 4.2 4.2
Physical data Outdoor Unit Equivalent HP 2HP 3HP 4HP 5HP
Out
door
unit
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E
Power supply 1-phase 50Hz 230V (220â240V)
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5
Max. pipe total length m 30 30 50 50
Maximum height difference m 30 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 890/900/320 890/900/320
Weight kg 40 44 68 68
Sound pressure level, Cooling/Heating*2 dB(A) 46/48 48/52 53/54 54/55
Operating range, Cooling/Heating °C -15~46 / -15~15
Out
door
unit
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E
Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E
Cooling*1
Capacity kW 5.0 6.7 10.0 12.0
Range, min-max kW 1.5-5.6 1.5-8.0 3.0-11.2 3.0-13.2
Power consumption kW 1.56 2.22 3.02 4.29
EER (Energy
Efficiency Ratio)
Capacity 100% 3.21 3.02 3.31 2.80
Capacity 80% 4.00 3.77 4.08 3.53
Capacity 50% 5.21 5.49 5.10 5.00
Heating*1
Capacity kW 5.3 7.7 11.2 12.8
Range, min-max kW 1.5-6.3 1.5-9.0 3.0-13.0 3.0-16.0
Power consumption kW 1.36 2.13 2.93 3.40
COP (Coefficient of
Performance)
Capacity 100% 3.90 3.62 3.82 3.76
Capacity 80% 4.37 4.22 4.23 4.30
Capacity 50% 5.41 5.50 5.19 5.12
Power supply 1-phase 50Hz 230V (220â240V)
Performance dataDI-Digital Inverter
10
11. RAV-SM***4UTP-E
155
28.5
61
5764
187
32
Celling
bottom
surface
Knockoutfor
fresh airintake Ď100
Z view
300orless
Stand-up
661orless
Stand-up850orless
Bottom faceofceiling Drain standing-up size
A
B
860to 910Ceiling open dim ension
860to910Ceilingopendimension
1000orm ore 1000orm ore
15or
more
15or
more
1000or
more
Space required forinstallation and servicing
Z
SM564UTP-E
SM1104UTP-E, SM1404UTP-E
AModel RAV-
256
319
74
137
B
(Unit:mm)
C D
12.7
15.9
6.4
9.5
SM804UTP-E 256 74
C D
15.9 9.5
Options
Packing A
Air discharge
parts A
Refrigerant
piping
side
Drain piping
side
Packing B
Packing B
Air discharge
parts B
Air discharge
parts C
Air inlet grille
Ceiling panel
Fresh air inlet box
Air discharge direction kit
Spacer for height adjustment
Spacer for height adjustment
RBC-U31PGP(W)-E
RBC-U31PGP(WS)-E
TCB-SP1602UE
TCB-GB1602UE
TCB-GFC1602UE
TCB-FF101URE2
TCB-BC1602UE
Bottom face of Ceiling
1000 or more1000 or more
1000or
more
15or
more
860to910Ceilingopendimension
Ceiling
Electric
parts box
Ceiling
860 to 910 Ceiling open dimension
Space required for installation and servicing
bottom
surface
Knockout for
fresh air intake
Drain standing-up size
Z view
300 or less
Stand-up850orless
Stand-up
661orless
15or
more
Hanging bolt M10 or
Ceiling panel
(sold separately)
of ceiling
Bottom face
For branch duct Knockout
square hole
(procured by locally)
Hanging bolt pitch
Panel external dimension
Panelexternaldimension
Hangingboltpitch
Bottomface
ofceiling
Take-inport
ofwiring
Drainpipe
connectionport
squarehole
(Material:PP)
Refrigerantpipe
connectingport
(Liquidside)
(Gaside)
Refrigerantpipe
connectingport
ForbranchductKnockout
1111
12. Compact sizing
Compact size especially in height (275 mm), new slimmer chassis offers wide range of
installation opportunities to customer.
Standard Duct type
rav-smâââ6Btp-E*
Wide range of application opportunities
High static pressure
External static pressure can be raised as high as 120 Pa, so that all areas of the room
can be reached for even temperature distribution, no matter how complex the layout.
275mm
275mm
Built-in High-lift drain pump#
The flexible piping layout is made possible by an optionally available drain-pump kit
that raises the drain piping up to 29 cm from the drain port.
Flexible duct is accessible, Allows complete design flexibility
Polygonal rooms Narrow rooms Rooms with fixtures
and obstacles
New spigot shaped flange as new accessories
New spigot shaped flange has higher static pressure with optimized
design, the static pressure drops only 20Pa from rectangle flange states.
Maximum Static pressure will be 100Pa* with all models.
(*static pressure with filter which included in, and intake from back ward)
.
.
Comfort
Inverter
Allows step-less regulation of the
air-conditionerâs power,which reduces
energy consumption and improves
comfort.
.
Hot Start
When using the heater for preheating
or defrosting, stops the indoor fan to
prevent cold air from being blown into
the room.
Dry
Gradually dehumidifies the room to
create even greater comfort.
Operativity
Filter Sign
Automatic displays on the remote
controller say when to perform
maintenance for the indoor unit filter.
Limit Timer
Uses a 168-hour timer with three
modes - âON timerâ, âOFF timerâ and
âRepeat OFF timerâ.
Installation
Cooler Compatible with an Outdoor
Temperature of -15 ° C
Stable cooler operation is possible
when the outdoor temperature is as
low as -15 ° C.
Built-in Drain Pump
The built-in drain pump makes
draining easier. (In the ceiling cassette
type, it is built in to the main unit.)
Long-life Filter
Built-in long-life filter makes
maintenance easier.
Automatic Air Volume control
Depending on the difference between
the room temperature and the set
temperature, switches automatically
between High, Low and Very Low.
Standard Duct type
Digital Inverter
Spigot shaped flange
TCB-SF56C6BEP
TCB-SF80C6BEP
TCB-SF160C6BEP
#Not available with 6HP and 10HPhigh static duct IDU
12
13. Physical data Equivalent HP 2HP 3HP 4HP 5HP 6HP
Out
door
unit
Standard model
(RAV-)
SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Heavy Anti-Corrosion protection model
(RAV-)
SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
Power supply 1-phase 50Hz 230V (220â240V) 1-phase 50Hz 230V (220â240V)
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 5
Max. pipe total length m 30 50
Maximum height difference m 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 890/900/320 1340/900/320
Weight kg 40 44 68 99
Sound pressure level, Cooling/Heating*2
dB(A) 46/48 48/52 53/54 54/55 51/53
Operating range, Cooling/Heating °C -15~46 / -15~15 -15~43 / -15~15
Physical data Indoor unit (RAV-)
SM406BT-E,
SM406BTP-E*
SM456BT-E,
SM456BTP-E*
SM566BT-E,
SM566BTP-E*
SM806BT-E,
SM806BTP-E*
SM1106BT-E,
SM1106BTP-E*
SM1406BT-E,
SM1406BTP-E*
SM1603DT-A
Standard air flow (H/M/L) CFM 469/370/282 469/370/282 469/370/282 706/547/423 1235/970/741 1235/970/741 2047
External static pressure (factory setting) Pa 30 30 30 30 50 50 100
External static pressure-Standard (Upper-Lower) Pa 30(120-30) 30(120-30) 50(120-30) 100(50-250)
Sound pressure level (H/M/L) dB(A) 33/29/25 33/29/25 33/29/25 34/30/26 40/36/33 40/36/33 50
Dimensions (H/W/D) mm 275/700/750 275/700/750 275/700/750 275/1000/750 275/1400/750 275/1400/750 380/1050/600
Weightkg 23 23 23 30 40 40 57
Out
door
unit
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
Indoor unit (RAV-)
SM566BT-E,
SM566BTP-E*
SM806BT-E,
SM806BTP-E*
SM1106BT-E, SM1106BTP-E*
SM1406BT-E,
SM1406BTP-E*
SM1603DT-A
Cooling*1
Capacity kW 5.0 6.7 10.0 12.1 14.3
Range, min-max kW 1.5-5.6 1.5-7.4 3.0-11.2 3.0-13.2 3.6-16.0
Power consumption kW 1.83 2.38 3.14 4.42 5.01
EER (Energy
Efficiency Ratio)
Capacity 100% 2.73 2.82 3.18 2.74 2.85
Capacity 80% 3.42 3.53 3.92 3.46 3.35
Capacity 50% 4.39 5.08 4.90 4.92 4.09
Heating*1
Capacity kW 5.3 7.7 11.2 12.8 16.0
Range, min-max kW 1.5-6.3 1.5-9.0 3.0-12.5 3.0-16.0 4.6-18.0
Power consumption kW 1.62 2.32 2.99 3.55 4.57
COP (Coefficient
of Performance)
Capacity 100% 3.27 3.32 3.75 3.61 3.50
Capacity 80% 3.69 3.87 4.15 4.11 3.68
Capacity 50% 4.57 5.07 5.09 4.89 3.91
Power supply 1-phase 50Hz 230V (220â240V) 1-phase 50Hz 230V (220â240V)
Performance dataDI-Digital Inverter Performance data
1313
14. RAV-SM***6BT(P)*-E
Options
SM566BT(P)*-E
SM806BT(P)*-E
SM1106BT(P)*-E, SM1406BT(P)*-E
Model RAV-
765
1065
700
1000
1400
640
940
1340
750
1050
1450
A B DC
345
355
108
37
232
Refrigerant pipe
connecting port
(Liquid side)
Refrigerant pipe
connecting port
(Gas side)
Air outlet
Ceiling
Service door (Ceiling opening)
Floor surface
25 25
D
100 or
more
700
or more
2500
ormore
275
5or
more
117.5
233
18
Drain pipe
connecting port
23320570
20
s
t
70or
more
A
B
C
D
E
E
1465
700
500
700
(Unit:mm)
F G
F
G
12.7
15.9
6.4
9.5
12.7 6.4
Space required for installation and servicing
TCB-SF56C6BE
TCB-SF80C6BE
TCB-SF160C6BE
Model
SM566BT(P)*-E
SM806BT(P)*-E
Compatible
SM1106BT(P)*-E, SM1406BT(P)*-E
TCB-SF56C6BE TCB-SF80C6BE
TCB-SF160C6BE
(Unit:mm)
TCB-SF56C6BE
TCB-SF80C6BE
TCB-SF160C6BE
Hanging bolt pitch
Unit external dimension
External dimensions of flange
A
B
C
E
1/100 or more downward
At the time of natural drainage
Under air intake type
Flexible drain hose
(Accessory)
Wires
drawing-out port
650
14
15. (Unit: mm)
20
10296
316
15
25
10
2525
20
60
276
(Inside)
274
(Inside)
757 (Inside) 845 (Inside)5252 0202
12
65 65
12 25 67.5 250 250
885
11 Ă 65 = 715
250 67.5
15
652652 271
807
11 Ă 65 = 715
4Ă60=240
300
324
15
25
60
4Ă60=240
10-Ă5 hole
(Include in the other side)
24-Ă5 hole
(Include in the other side)
24-Ă5 hole
(Include in the other side)
8-Ă7 hole
10-Ă5 hole
(Include in the other side)8-Ă7 hole
Flange (Air outlet side) Flange (Air inlet side)
Plug
(Port for check
and clean)
Drain pipe
Adhesive inhibited
Check port
400 Ă 800
50
ormore
100
ormore1300ormore
200
200
ormore
Service work space
Drain trap
704
12
32
52
30
50
950(Boltpitch)(50)(50)
(900)(95)
1050
965(Boltpitch)(35)(50)
(36)
(53)
(72)(915)
664
25
48490
25 (111) 854 (85)
14514520
(30)
975042
380
271(28)81
600
2)006 5 () 25 (
wo l f r i Awo l f r i A
Hung-up plate
Refrigerant piping (5/8â (Ă15.88))
Refrigerant piping (3/8â (Ă9.52))
Refrigerant piping (3/8â (Ă9.52))
3-M5 hole for drain pump kit
Refrigerant piping (5/8â (Ă15.88))
Drain port (Outer diameter: Ă32)
Electric parts box Drain port (Outer diameter: Ă32)
RAV-SM 1403DT-A, RAV-SM 1603DT-A
(Unit: mm)
20
10296
316
15
25
10
2525
20
60
276
(Inside)
274
(Inside)
757 (Inside) 845 (Inside)5252 0202
12
65 65
12 25 67.5 250 250
885
11 Ă 65 = 715
250 67.5
15
652652 271
807
11 Ă 65 = 715
4Ă60=240
300
324
15
25
60
4Ă60=240
10-Ă5 hole
(Include in the other side)
24-Ă5 hole
(Include in the other side)
24-Ă5 hole
(Include in the other side)
8-Ă7 hole
10-Ă5 hole
(Include in the other side)8-Ă7 hole
Flange (Air outlet side) Flange (Air inlet side)
Plug
(Port for check
and clean)
Drain pipe
Adhesive inhibited
Check port
400 Ă 800
50
ormore
100
ormore1300ormore
200
200
ormoreService work space
Drain trap
704
12
32
52
30
50
950(Boltpitch)(50)(50)
(900)(95)
1050
965(Boltpitch)(35)(50)
(36)
(53)
(72)(915)
664
25
48490
25 (111) 854 (85)
14514520
(30)
975042
380
271(28)81
600
2)006 5 () 25 (
wo l f r i Awo l f r i A
Hung-up plate
Refrigerant piping (5/8â (Ă15.88))
Refrigerant piping (3/8â (Ă9.52))
Refrigerant piping (3/8â (Ă9.52))
3-M5 hole for drain pump kit
Refrigerant piping (5/8â (Ă15.88))
Drain port (Outer diameter: Ă32)
Electric parts box Drain port (Outer diameter: Ă32)
RAV-SM 1403DT-A, RAV-SM 1603DT-A
1515
16. rav-smâââ2dt-E
Design flexibility
Compatible with external static pressures up to 196 Pa.
Concealed Duct High Static Pressure type
Satisfies all your design needs
Concealed Duct High Static Pressure type
DI BIG
.
Comfort
Inverter
Allows step-less regulation of the
air-conditionerâs power,which reduces
energy consumption and improves
comfort.
.
Automatic Air Volume control
Depending on the difference between
the room temperature and the set
temperature, switches automatically
between High, Low and Very Low.
.
Hot Start
When using the heater for preheating
or defrosting, stops the indoor fan to
prevent cold air from being blown into
the room.
Operativity
Filter Sign
Automatic displays on the remote
controller say when to perform
maintenance for the indoor unit filter.
Limit Timer
Uses a 168-hour timer with three
modes - âON timerâ, âOFF timerâ and
âRepeat OFF timerâ.
Installation
Cooler Compatible with an Outdoor
Temperature of -15 ° C
Stable cooler operation is possible
when the outdoor temperature is as
low as -15 ° C.
3-steps-switchable static pressure
Large air volume, Duct high static pressure type is most
suitable for the large rooms. Long-life filters fitted as standard.
Can be equipped with the following options:
⢠high-efficiency filter (65, 90)
⢠drain pump kit (optional)
Low Middle High
External static pressure (Pa) 68.6 137.0 196.0
Construction characteristics
The flexible duct is accessible.
Constant temperature setting is possible in large rooms or factories.
Easy service and installation.
Enable to maintain the blower section from unit side for maintenance and repair.
Enable to select auto restart operation (set from wired remote controller)
*Factory setting : 137Pa
Dry
Gradually dehumidifies the room to
create even greater comfort.
16
17. MML-AP***4NH-EOutdoor unit (RAV-) SM2804AT8-E
Indoor unit (RAV-) SM2802DT-E
Cooling*1
Capacity kW 23.0
Range, min-max kW 9.8-27.0
Power consumption kW 8.75
EER
(Energy Efficiency Ratio)
Capacity 100% 2.63
Capacity 80% 3.24
Capacity 50% 4.49
Heating*1
Capacity kW 27.0
Range, min-max kW 9.8-31.5
Power consumption kW 8.15
COP
(Coefficient of
Performance)
Capacity 100% 3.31
Capacity 80% 3.80
Capacity 50% 4.77
Power supply 3-phase 50Hz 380â 415V
DI BIG Performance data
Physical data Indoor unit (RAV-) SM2802DT-E
Standard air flow at 137Pa/ (at Mid tap) CFM 2470
External static pressure (H/M/L) Pa 196/137/68.6
Sound pressure level (H/M/L) dB(A) 55
Dimensions (H/W/D) mm 470/1380/1250
Weightkg 160
Physical data Equivalent HP 10HP
Outdoor unit (RAV-) SM2804AT8-E
Power supply 3-phase 50Hz 380â 415V
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø28.6 / ø12.7
Min. pipe length m 7.5
Max. pipe total length m 70
Maximum height difference m 30
Outer dimensions (H/W/D) mm 1540/900/320
Weight kg 134
Sound pressure level, Cooling/Heating*2
dB(A) 57/58
Operating range, Cooling/Heating °C -15~46 / -20~15
RAV-SM***2DT-E
Filter chamber
TCB-FCY100DE
TCB-PF3DE
Drain pump kit
TCB-DP32DE
TCB-UFM3DE
TCB-UFH7DE
Options
(4-12 Ă 92)
600
1288
1328
624
698
1250
250
37065
250
35
250
22
46
250
002051
31
200
250
3540629
470
45
250 250 250
1260
1380100
65
1000
200
190
190
Space required for installation and serving
Hole for hanging bolt
Service space
Refrigerant pipe connecting port
(Gas side Brazed)
ormore
*
Check port
Service space
Service space
(Hanging bolt mounting pitch)
(Hangingboltmountingpitch)
Air discharge port
Screw hole for duct mounting (10-M6)
Air suction port
Refrigerant pipe connecting port
(Liquid side 12.7 Flared)*
Drain pipe connecting port (V25)
Taper screw for R1,25.4 pipes
Electric parts box
Power supply/communication piping
port (Ă26) (Under electric parts box)
Screw hole for duct mounting (10-M6)
(Unit:mm)
ormore
(Unit:mm)
22.2 12.7
Diameter of pipe connecting port Diameter of pipe connecting pipe
Gas sideLiquid side Gas sideLiquid side
12.7 28.6
1717
19. Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette
SM1104AT(J)P-E SM564UTP-E 4 10.0 3.0-11.2 3.02 3.31 4.08 5.10
SM1404AT(J)P-E SM804UTP-E 5 12.0 3.0-13.2 4.29 2.80 3.53 5.00
SM1603AT(Z)(ZG)-E SM804UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86
Standard Duct
SM1104AT(J)P-E SM566BTP-E* 4 10.0 3.0-11.2 3.14 3.18 3.92 4.90
SM1404AT(J)P-E SM806BTP-E* 5 12.1 3.0-13.2 4.42 2.74 3.46 4.92
SM1603AT(Z)(ZG)-E SM806BTP-E* 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24
Twin system : DI-Digital Inverter 1-phase
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette
SM1104AT(J)P-E SM564UTP-E 4 11.2 3.0-13.0 2.93 3.82 4.23 5.19
SM1404AT(J)P-E SM804UTP-E 5 12.8 3.0-16.0 3.40 3.76 4.30 5.12
SM1603AT(Z)(ZG)-E SM804UTP-E 6 16.0 3.0-18.0 4.43 3.61 4.59 4.91
Standard Duct
SM1104AT(J)P-E SM566BTP-E* 4 11.2 3.0-12.5 2.99 3.75 4.15 5.09
SM1404AT(J)P-E SM806BTP-E* 5 12.8 3.0-16.0 3.55 3.61 4.11 4.89
SM1603AT(Z)(ZG)-E SM806BTP-E* 6 16.0 3.0-18.0 4.69 3.41 4.04 4.32
Twin system : DI-Digital Inverter 1-phase
Cooling
Heating
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(Z)(ZG)-E SM1404UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79
Standard Duct SM2804AT8(Z)(ZG)-E SM1406BTP-E* 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62
Twin system : DI Big 3-phase
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(Z)(ZG)-E SM1404UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21
Standard Duct SM2804AT8(Z)(ZG)-E SM1406BTP-E* 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91
Twin system : DI Big 3-phase
Cooling
Heating
Twin, Triple and Double twin system
1919
20. Twin, Triple and Double twin system
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21
Standard Duct SM2804AT8(ZG)-E SM806BTP-E 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91
Triple system : DI Big 3-phase Heating
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79
Standard Duct SM2804AT8(ZG)-E SM806BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62
Triple system : DI Big 3-phase Cooling
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E 6 16.0 3.0-18.0 4.43 3.61 4.59 4.91
Standard Duct SM1603AT(Z)(ZG)-E SM566BTP-E* 6 16.0 3.0-18.0 4.69 3.41 4.04 4.32
Triple system : DI-Digital Inverter 1-phase Heating
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86
Standard Duct SM1603AT(Z)(ZG)-E SM566BTP-E* 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24
Triple system : DI-Digital Inverter 1-phase Cooling
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79
Standard Duct SM2804AT8(ZG)-E SM566BTP-E* 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62
Double twin system : DI Big 3-phase Cooling
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21
Standard Duct SM2804AT8(ZG)-E SM566BTP-E* 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91
Double twin system : DI Big 3-phase Heating
20
21. Indoor unit Parts Name Model Name Applied Model Remarks
4-Way Cassette type
Ceiling panel
RBC-U31PGP(W)-E,
RBC-U31PGP(WS)-E
RAV-SM***4UTP-E
Fresh air inlet box TCB-GB1602UE Use with TCB-GFC1602UE
Fresh air filter chamber TCB-GFC1602UE
Auxiliary fresh air flange TCB-FF101URE2
Spacer for height adjustment TCB-SP1602UE
Air discharge direction kit TCB-BC1602UE
Standard Duct type Spigot shaped flange
TCB-SF80C6BE RAV-SM806BTP-E*
TCB-SF160C6BE RAV-SM1106BTP-E* RAV-SM1406BTP-E*
Concealed Duct High Static
Pressure type
High-efficiency filter 65 TCB-UFM3DE
RAV-SM***2DT-E
Use with TCB-FCY100DEHigh-efficiency filter 90 TCB-UFH7DE
Long life prefilter TCB-PF3DE
Filter chamber TCB-FCY100DE
Drain pump kit TCB-DP32DE
Indoor unit accessories
Parts Name Model Name Type
Branch kit
RBC-TWP30E
Digital Inverter 1-phase model
RBC-TWP50E
RBC-TWP101E 1:2 Twin system of Dl Big model
RBC-TRP100E 1:3 Digital Inverter 1-phase model and DI Big model
RBC-DTWP101E 1:4 Double twin system of DI Big model
Digital Inverter - Controllers Accessories
Parts Name Model Name Applied Model Features
Wired remote controller
RBC-AMT32E All indoor units Standard type
RBC-AMS41E All indoor units Remote controller with weekly timer
RBC-AMS51E-ES/-EN All indoor units Remote controller with LCD display with backlight
Simple wired remote controller RBC-AS41E All indoor units With Simplified control
Wireless remote controller kits
RBC-AX32U(W)/(WS)-E 4-Way Cassette type Integral receiver type
TCB-AX32E2 All indoor units Standalone receiver type
Remote controller kits
TCB-EXS21TLE Use with wired remote controller Remote controller with schedule timer
TCB-CC163TLE2
Used with wired remote controller / Central remote
controller
On-Off controller combined with the weekly timer
TCB-SC642TLE2 All indoor units Central remote controller
BMS-CM1280TLE All indoor units Compliant manager
TCC-Link* TCB-PCNT30TLE2 All indoor units except High-wall type Use with Remote controller kit
Indoor unit controllers
* : TCC-Link Adaptor for Digital Inverter units.
2121
22. Standard Remote controller
RBC-AMT32E
Standard wired remote controller can be connected to a single indoor unit
or a group of up to 8 indoor units. Power save operation limits the greatest
current value.The remote controller allows error to be displayed
while the protective device works or a error occurs.
Remote controller with weekly timer
(7-day timer function)
RBC-AMS41E
Wired remote controller with clock display and a built in 7-day timer function,
possible to program 8 functions for each day of the week.
*The following items can be set in program: operation time,
operation start/stop, operation mode, temperature setting,
restriction on button operation
Lite-Vision plus Remote Controller
RBC-AMS51E-ES
RBC-AMS51E-EN
Wired remote controller with a built in 7-day timer-featuring a new multi-language,
LCD display with backlight, energy saving options and a return back function.
⢠Possibility to set and display the room name to easily set-up and monitor the working parameter.
⢠New modern and desirable controller design with menu driven display.
⢠Save mode by schedule timer to optimise energy consumption.
⢠Room temperature display always available.
⢠TwoâHot Keysâ(F1, F2) for easy operation of air conditioner functions.
⢠Easy to read layout including display of indoor unit model name and serial number.
⢠Built-in backup power. Settings are kept in memory up to 72 hours in case of power failure.
⢠Remote TA sensor available in controller.
⢠Can be connected to a single indoor unit or a group of up to 8 indoor units.
Simple wired remote controller can be connected to a
single indoor unit or a group of up to 8 indoor units.
⢠Start/Stop
⢠Temperature setting
⢠Air flow changing
⢠Check code display
Simple wired remote controller
RBC-AS41E
Wireless remote controller kit
⢠Start/Stop â˘Changing mode â˘Temperature setting
⢠Air flow changing
⢠Timer function EitherâONâtime orâOFFâtime or
âCYCLICâcan be set how many 30 min. later ON or OFF
is operated.
⢠Control by 2 remote controllers is available.
Two wireless remote controllers can operate
one indoor unit. The indoor unit can then be
operated separately from the two different locations.
⢠Check code display
RBC-AX32U(W)/(WS)-E
Integral receiver
(For 4-way cassette)
TCB-AX32E2
Sensor unit; Stand alone receiver
(For 4-way cassette), (Duct type)
Schedule timer
TCB-EXS21TLE
Central remote
controller
BMS-CM1280TLE
⢠Schedule timer mode
â 6 programmings per day
â Enabling 8 groups to be programmed
â A maximum of 64 indoor units can be controlled
â A maximum of 100 hours back-up power supply
⢠Weekly timer mode
â 7 types of weekly schedule and 3 programmings
per day
ON-OFF controller
TCB-CC163TLE2
⢠Individual control of up to 16 indoor units.
⢠Setting of simultaneous ON/OFF 3 times per
day combined with the weekly timer.
Central remote controller
TCB-SC642TLE2
⢠Individual control for max. 64 indoor units divided
into 1 to 4 zone (Up to 16 indoor units for each zone)
⢠Up to 16 outdoor header units are connectable
⢠4 types of central control settings to inhibit individual
operation by remote controller can be selected
⢠Usable with other central control devices
(Max. 10 devices in one control circuit)
⢠Two control mode selectivity
(Central controller mode ) Remote controller mode
⢠Setting of simultaneous ON/OFF 3 times per day
combined with the weekly timer.
⢠Operation
Individual operation of 128 indoor units available
Return Back Operation
Weekly Schedule Operation*
(ON/OFF)
* Schedule timer necessary
⢠Monitoring
Zone setting (64 zones x 2)
Individual unit operation mode operation restriction
Alarm display
Control input
Status output
Remote controllers
22
23. Discharge guide mounting hole
(4-dia.4.5 embossing)
charge port Earth terminal
Discharge guard
B legs
A legs
Drain hole
(Longholepitch
Foranchorbolt)
(2-dia. 20x88 long hole)
Drain hole(dia. 25)
2-dia. 11-14 U-shape hole
(For dia.8-10 anchor bolts)
Refrigerant pipe
connecting port
(dia. 12.7 flare at gas side)
Refrigerant pipe
connecting port
(dia. 6.4 flare at liquid side)
8-dia. 6 hole
2-dia. 11xL14 long hole
For fixing outdoor unit
(For dia. 8-10 anchor bolts)
dia.holepitch
8
35
52
550
21
6
69.5 147
32 500
780
71
25
22
257483
108
600 90
54108 125
157 79
31 143
145
21
449
483
30
60
30
27
290
306
320
137
93
342
54
dia. 11x14 U-shape hole
Product
external line
Details of B legs
2-dia. hole
R15
600
38
54
320
R15
2-dia. 6 hole
Product
external line
Details of A legs
dia. 11x14 U-shape hole
600
54
38
11
320
2-dia. 11x14 U-shape hples
(For dia. 8-10 anchor bolt)
Suction port
or more
or more
or more Discharge
port
Discharge
port
2-dia. 11x14 long hole
(For dia.8-10 anchor bolt)
or more
600
300
500
150
320
(Unit: mm)
Space required for installation and servicing
(Unit: mm)
DI Digital Inverter 2-3HP : Outdoor unit drawings
2323
24. DI Digital Inverter 4HP and 5HP: Outdoor unit drawings
Mounting bolt hole
(dia. 12x17 long hole)
Details ofA legs
Mounting bolt
(dia. 12x17 U-shape hole)
Details of B legs
40
40
12
17.536517.5
Drain hole(dia. 20x88)
74118128
Air inlet
port
380
2006 0
Air inlet
port
Air outlet
port
Drain hole(dia. 25)
B legs
46
34
170
75
70383
150 600
A legs
39
96
320
30
2
1
890
24
400
151
8018
9555
94
2
1
255
247
155
1880
135
900
55052
Refrigerant pipe
connecting port
(dia. 9.5 flare at liquid side)
Refrigerant pipe
connecting port
(dia. 15.9 flare at gas side)
9555
17817817860
327
68 518
83 7
765
9555
12 64
1
1
2
Knockout for downward piping
Z views
Refrigerant piping hole
Indoor/Outdoor unit
connecting wire inlet hole
Name Note
Power supply inlet holed ia. 38 Knockout hole
581
534
148
165
(Unit: mm)
24
25. DI Digital Inverter 6HP : Outdoor unit drawings
Name Note
Refrigerant piping hole
Indoor/Outdoor unit
connecting wire inlet hole
ââ
Power supply inlet hole Ă38 Kockout hole
1
2
36517.5
74
17.5
128
46
48
40
40
54
34
170
118
380
383
150 600
70
96
39
12
75
200 60
Air inlet port
Air inlet
port
Air outlet
port
Drain hole (Ă28 Ă 88)
Drain hole (Ă25)
Mounting bolt hole
(Ă12 Ă 17 long hole)
Mounting bolt hole
(Ă12 Ă 17 U-shape hole)
B legs
Details of A legs Details of B legs
A legs
5595
21 64
1
657
83 7
Knockout for downward piping
ws
655
12153453485
5595
55
94
95
24
1340
155
605
613
4710875185
360
900
550
60
151531815
400
08810887187 11 8
30
52
320
Refrigerant pipe
connecting port
Refrigerant pipe
connecting port
(Ă15.9 flare at gas side)
2
1
2
1
86
178
327
Z views
(Unit: mm)
2525
26. DI Big 10HP: Outdoor unit drawings
Knockout (for drain)
Drain hole
(Ă28 x 88 bearing hole)
Drain hole
(Ă25 bearing hole)
B legs
A legs
Air inlet
port
Knockout
(for drain)
Air outlet
Mounting bolt hole
(Ă12 x 17 long hole)
Mounting bolt hole
(Ă12 x 17 U-shaped hole)
Details of A legs Details of B legs
Refrigerant pipe
connecting port
(liquid side)
Refrigerant pipe
connecting port
(gas side)
Z views
Knockout for downward piping
Air inlet
port
Since the connection diameter of the ball valve in the outdoor unit main body is
Ă19.1, use the attached coupling pipe when performing maintenance.
etoNemaN
a
Refrigerant piping hole
Indoor/Outdoor unit
connecting wire inlet hole
â
b Power supply inlet holeĂ 38 Knockout hole
Piping Connection Aperture
Radius
Connection
Piping Radius
LiquidG as LiquidG as
12.71 9.1 12.7 28.6
*
*
(Unit: mm)
26
27. Precautions for using air conditioners
Concerning the automatic defrosting unit
When the outdoor air temperature drops, frost may form on the
heat exchanger of the outdoor unit. In such cases, the automatic
defrosting unit will be activated, and it will take 5 to 8 minutes for the
heating operation to be restored.
Concerning the air conditioner's operating conditions and their
selection
(1) Avoid using the air conditioner in the following locations.
⢠Locations with acidic or alkaline atmospheres (locations at which
highly acidic or alkaline air is directly drawn in, such as in hot
springs areas from which sulfur gases are given off, or where
chemicals, vinegar, exhaust air from burners, etc., are given off)
The heat exchangers and other parts may become corroded.
⢠Locations with atmospheres filled with coolant or other machine
oil or steam exhaust (such as at food preparation factories or
machine plants). The heat exchangers may corrode; frost may
form as a result of heat exchanger malfunction; air conditioner
operating performance may be compromised or condensation
may form as a result of clogged filters; plastic parts may incur
damage; heat-insulation materials may become separated, etc.
(2) Before using an air conditioner in any of the following locations,
consult with your dealer or a qualified contractor.
⢠Locations where vapors from edible oils are given off (such
as in bakeries or kitchens and restaurants that use edible
oils) ...The air conditioner's operating performance may be
compromised or condensation may form as a result of clogged
filters, and the plastic parts may incur damage. In line with the
prevailing conditions, take countermeasures such as tailoring the
installation conditions in accordance with the conditions, using
air conditioners designed for kitchens or oil guard filters, etc.
⢠Locations with disinfectant-induced chlorine atmospheres (water
tanks, etc.) The metal parts in the heat exchangers, motors, etc.,
may become corroded.
⢠Locations with high salinity (coastal areas, etc.) Corrosion
may occur so use outdoor units specifically designed to
withstand exposure to salt.
⢠Locations where power is supplied from independent power
generators. The power line frequency and/or voltage may
fluctuate, possibly causing the air conditioner to malfunction.
⢠Locations where high frequencies or electrical noise is
generated (from high-frequency welders used for vinyl welding
and processing, high-frequency therapeutic devices used
for thermotherapy, etc.) The electronic components may be
adversely affected, possibly causing the air conditioner to
malfunction.
⢠Locations where electronic equipment is installed. Electrical
noise may adversely affect the operation of the electronic
equipment.
(3) Concerning use in locations with high ceilings
⢠In locations with high ceilings, use of circulators for improving
the temperature distribution during heating is recommended.
(4) Concerning use in high-humidity environments
⢠When the ceiling-recessed type of indoor unit is installed in a
location, such as those described below, and it is very hot and
humid inside the ceiling, condensation may form on the external
surfaces of the indoor unit and drip down. In such cases, add
external heat-insulating materials.
â Locations such as food preparation sites in which the areas
above the ceilings are hot and humid
â Locations in which outside air is drawn in and routed above the
ceiling
â Above ceilings with a slate roof or tiled roof overhead
(5) Even when an air conditioner is shut down, it will still consume a
small amount of power to protect the unit. If the air conditioner
will not be used for a prolonged period, turn OFF the main switch
(ground fault circuit breaker). However, before the unit is to be
used again, turn ON the main switch (ground fault circuit breaker)
for at least 12 hours in order to prevent trouble.
SAFETY PRECAUTIONS
For operation:
⢠Before use, read through the operating instructions to ensure proper use.
Concerning the purpose for which the air conditioners are to be used
⢠The air conditioners presented in this catalogue are air conditioning/heating units to be used solely by general consumers.
â Do not use these air conditioners for special applications such as for the storage of food items, animals, plants, precision machines or works
of art. Doing so may degrade the quality of the items.
â Do not use these air conditioners for air-conditioning applications in vehicles or ships. Doing so may cause water and/or power leakages.
Installation and the use of refrigerants not specified by Toshiba Carrier Corporation
Toshiba refrigeration and air-conditioning units are designed and
manufactured on the assumption that the product is used with a
specific refrigerant suitable for each unit.
We have recently seen some cases where the type of refrigerant
used is different from the one originally installed in the product.
Such actions may cause mechanical defects, malfunctions, failures
and in some cases result in a serious safety issue. Therefore do
not install any refrigerant other than the one specified by Toshiba
Carrier Corporation for its respective products.
The type of the refrigerant used for each of our products is shown in the
accompanying owners manual, or on the product label attached on the
product itself.
Toshiba Carrier Corporation shall not assume any liability for failures,
malfunctions or safety in its products if the refrigerant used is different
from the one specified.
2727