SlideShare a Scribd company logo
1 of 30
Download to read offline
HomePro Inspection Inc
                       Knowledge             Experience               Integrity
  Cover Page
                              PROPERTY INSPECTION REPORT




        Thank you for trusting me to perform your inspection so that you may
                                    Know What I See!




                                   Photo distorted on purpose, 30728
                               Inspection prepared for: Rural 2007 Built
                                Inspection Date: 4/1/2011 Time: 1:00 PM
                                    Age: Built 2007 Size: 3300 Sqft
                                             Weather: Clear

                                      Inspector: Roger Williamson
               License # 226 TN - ASHI Certified Member # 204213 - Proud Member BBB
                             2409 Haven Crest Dr, Chattanooga, TN, 37421
                                         Phone: 423-421-4913
                                Email: HomeProInspection@EPBFI.com
                                    www.HomeProInspection.com




HomePro Inspection Inc 423-421-4913 ________________For Photo Integrity, Please Do Not Fax This Report
Rural 2007 Built                                                                              Photo distorted on purpose

                                                INSPECTION AGREEMENT

                               Major Structural and Electromechanical Inspection

  COMPANY agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the
  condition of the property in accordance with the American Society of Home Inspectors (ASHI) and the State of
  Tennessee STANDARDS. The inspection and written report are performed and prepared for the sole, confidential and
  exclusive use and possession of the CLIENT; the report is nontransferable.

  The written report will include the following only:
  * general exterior, including roof, siding, windows, chimney, drainage and grading
  * structural condition of foundation &frame
  * electrical, plumbing, hot water heater, heating and air conditioning
  * general interior, including ceilings, walls, floors, windows, insulation and ventilation

  Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance
  inspection or certification for past or present governmental codes or regulations of any kind and is only based on the
  inspectors opinions.

  It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual
  observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and
  deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. Detached
  structures are not included. The COMPANY will be under no obligation under any circumstances for any further follow-
  up inspection.

  ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides,
  Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all
  Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In
  addition, no inspection for household insects or unwanted animals will be done.

  This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel
  Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Private Water,
  Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas,
  Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not
  a part of the inspection process.

  The parties agree that the COMPANY, and its employees and agents, assume no liability or responsibility for the cost of
  repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property
  damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED
  AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR
  PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE COMPANY IS NOT AN INSURER OF
  ANY INSPECTED CONDITIONS.

  It is understood and agreed that should COMPANY and/or its agents or employees be found liable for any loss or
  damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of
  contract or otherwise, then the liability of COMPANY and/or its agents or employees, shall be limited to a sum equal to
  the amount of the fee paid by the CLIENT for the Inspection and Report.

  The parties agree that the faxed copy of the agreement is to be relied upon in lieu of the original.

  Roger T. Williamson
  Roger T Williamson
  ASHI Certified Member # 204213
  TN License # 226
  Proud Member of the BBB



Roger Williamson                                          Page 1 of 29                           HomePro Inspection Inc
Rural 2007 Built                                                                         Photo distorted on purpose

  HOW TO READ THIS REPORT
  This report is prepared with digital photos and therefore a faxed copy is not equivalent to the original and should not be
  utilized. The inspector when allowed posts the Home Inspection Report for download to the website
  www.HomeProInspection.com.

  This report is prepared using the Standards of Practice set forth by The American Society of Home Inspectors and The
  Tennessee Department of Commerce. A full copy of these standards is available at their respective websites: ASHI.org
  and Tennessee.gov.

  This report lists and describes specific attributes about the inspected property. Throughout the report you will find
  information regarding maintenance, upgrades or repairs that you should consider and act on when appropriate.

  PHOTOS
  Photos included in this report are intended to help describe a reported item or area only. The photos, while
  representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be
  based on actual condition of property and not solely on the photos included in this report.

  SUMMARY
  For convenience the report contains a summary. You should evaluate your risk exposure for the items listed here and
  appropriately schedule proper repairs by qualified competent contractors.

  Occasionally the inspector may also include a reminder NOTE TO CLIENT in the summary to let you know to obtain
  certain documentation or if the utilities were off during the inspection.

  ACCEPTABLE
  In the body of the report you will see items listed as ACCEPTABLE. This term is used for items that are typically
  stationary, non mechanical and considered generally serviceable within the parameters of their given service life.
  Cosmetic appearance is not taken into account when rating an item as Acceptable.

  HAZARDOUS
  Items listed as hazardous pose imminent danger to the inspected property or occupants. Hazardous situations should be
  properly corrected by qualified competent contractors before occupying the property.

  PERIODIC MAINTENANCE NEEDED
  In the body of the report you may see items listed as PERIODIC MAINTENANCE NEEDED. These items are not unusual
  for the type and age property inspected. Some of these items may be recurring maintenance that has been postponed.
  You should evaluate your risk exposure for the items listed here and appropriately schedule proper repairs by qualified
  competent contractors.

  MONITOR
  In the body of the report you may see items listed as MONITOR. Typically these are items or areas that need subsequent
  observations and should be monitored over time to obtain historical data. These items may or may not require correction
  in the future based upon their performance over time. If you are unable to do the monitoring the inspector recommends
  you appropriately schedule monitoring by a qualified competent contractor.

  PRE-DATE
  In the body of the report you may see items listed as PRE-DATE. These items or areas are where construction may have
  been completed before the current safety standards were in place or in some cases where local code variances may
  exist. You should evaluate your risk and liability exposure for these items or areas and consider upgrading for safety or
  function.




Roger Williamson                                        Page 2 of 29                         HomePro Inspection Inc
Rural 2007 Built                                                                   Photo distorted on purpose

                                               Outdoor Areas
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  outdoor areas. Any exterior conditions requiring correction should be performed by a competent
  qualified contractor.

  1. Site


  Sloping

  Adjust Grade - Some landscape grade work may improve storm water run off away from foundation. Slope grade
  minimum ten feet away from and around structure so that water does not collect at home.

  2. Vegetation


  Grass, shrubs and trees near dwelling were observed

  No adverse conditions were observed

  3. Driveway
  Material:

  Concrete


  Cracks expansion/settlement - Noticeable cracking was observed. This is not unusual. Monitor and repair as needed.

  4. Walkway
  Observations:

  Concrete

  Cracked Acceptable

  5. Exterior Stairs
  Observations:

  Brick

  No adverse conditions were observed

  6. Porch
  Material:

  Tile

  Covered

  No adverse conditions were observed




Roger Williamson                                    Page 3 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                        Photo distorted on purpose

  7. Patio


  Tile
  Water appears to pond at rear patio. Monitor area brooming after rains or correct to meet your needs.



  All guard rails are less than 36" tall, hand rail at steps is ok at 34"
  Guardrails where required at elevated walk areas should be at least 36" tall for safety to help reduce falls. The installed
  guardrail is less than 36” tall. Evaluate your risk exposure correcting as needed for function or safety.

  Some spindle spacing is too wide
  Spindle Spacing – Railing spindles should be close together to help prevent falls or entrapment. Spindles should be
  constructed to reject a 4” sphere or ball being passed through the spindles. Evaluate your risk exposure and properly
  correct as needed for safety and function.




Roger Williamson                                       Page 4 of 29                         HomePro Inspection Inc
Rural 2007 Built                                                                    Photo distorted on purpose

                                                      Exterior
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  exterior and exterior surfaces of the structure. Any exterior conditions requiring correction should be
  performed by a competent qualified contractor.

  1. Exterior Entry Doors
  Material:

  Metal Clad

  Fiberglass

  No adverse conditions were observed

  2. Soffit
  Material:

  Vinyl soffits with metal fascia

  The exterior of the home was inspected and the eaves appears to be in overall good condition. No immediate repairs
  are needed at this time.

  3. Siding - Masonry


  Brick Veneer

  PERIODIC MAINTENANCE NEEDED

  Cracks Minor - Some cracks were noted that are minor in nature. Small settlement cracks are a common occurrence
  and can be repaired, providing that the settlement has stopped.

  Brick size hole observed at right exterior
  Incomplete - Typical scope of work for item inspected has not been completed. Additional work/repair should be
  properly performed to complete area.




                                                Brick size hole observed




Roger Williamson                                    Page 5 of 29                        HomePro Inspection Inc
Rural 2007 Built                                                                       Photo distorted on purpose

  4. Trim


  Material: Wood where installed

  Repainting new homes - All painted exterior surfaces subject to decay on newer homes should be properly cleaned,
  caulked and repainted within the first three years after the home is built to preserve these components. Subsequent
  paintings are typically scheduled every 8-10 yrs.

  5. Covered Parking Condition


  Attached Garage

  Installed drywall was observed on the garage ceiling framing. This offers some protection against the spread of fire
  from the garage to other areas.

  Installed drywall was observed on the walls that separate the garage and living space framing. This offers some
  protection against the spread of fire from the garage to other areas.


  Cracks expansion/settlement - Noticeable cracking was observed. This is not unusual. Monitor and repair as needed.

  6. Garage Overhead Door


  Metal

  Sectional

  Insulated

  Garage overhead door was tested using electric operator.

  7. Garage Overhead Door Operator


  Electric Operator


  Both units

  Non-Contact Reversal Satisfactory - The electronic eye of the operator was tested and found to be functioning
  normally.

  PERIODIC MAINTENANCE NEEDED

  Both units

  Contact Reversal Failed - The contact reversal was tested using a 1.5 inch obstruction on the floor at the center of the
  door. The operator pinned the obstruction without reversing. Adjust the force of the operator or the door mechanics as
  needed for proper operation and safety.




Roger Williamson                                      Page 6 of 29                         HomePro Inspection Inc
Rural 2007 Built                                                                    Photo distorted on purpose

                                                      Roofing
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  roof on the day of inspection. This inspection is not a warranty of the roof system or a determination
  of how long it may be water tight. Any roof conditions requiring correction should be performed by a
  competent qualified contractor.

  1. Access/Weather
  Access:

  Inspector walked portions of roofing

  Weather was clear during inspection


  Estimated Age

  2-5 Years old

  Style of roofing

  Hip

  Gable

  Monitor irregular roof slope details correcting when necessary

  2. Roof Covering
  Type of roofing installed

  Composition Shingle

  Metal


  Damaged shingles were observed
  Apparent moisture damage observed at dining room wall may or may not be related to roof condition.
  Roofing is ready for periodic maintenance. Have a qualified competent contractor check entire roof system and
  associated flashings. Repair or replace affected areas as needed.




                  Monitor irregular roof sloping                            Monitor irregular roof sloping




Roger Williamson                                     Page 7 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                   Photo distorted on purpose




                        Damaged shingle                                          Damaged shingle
  3. Roof Penetration


  Plumbing Vents - MONITOR this type of penetration as the gasket about the plumbing waste pipe penetrating the roof
  requires periodic maintenance. Budget replacement of plumbing vent gaskets as they begin to split. This is needed
  each 8-10 years after the roof is installed.

  4. Flashing


  Metal where visible

  5. Gutters / Downspouts
  Material:

  Metal

  Discharge Underground - One or more downspouts are discharging into a below grade drainage system. The drainage
  system is inaccessible and therefore not inspected.

  PERIODIC MAINTENANCE NEEDED

  Discharge near foundation - Downspouts are discharging close to the foundation. This may cause water to enter the
  building. It is recommended that all downspouts be extended to allow water to flow quickly away from and around
  structure. Correct as needed.

  Clean Gutters - The gutters were viewed with debris in them and some downspouts may be obstructed. Although this
  is a maintenance item, the condition viewed may cause damage to the soffits or fascia and should be corrected soon.
  PERIODIC MAINTENANCE NEEDED

  6. Chimney
  Materials:

  Top of chimney was not accessed by inspector




Roger Williamson                                    Page 8 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                           Photo distorted on purpose

                                                             Attic
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  attic. Attic conditions requiring correction should be performed by a competent qualified contractor.

  1. Attic Access


  Scuttle hole to attic

  2. Attic Framing


  Wooden Rafters


  MONITOR or correct
  Hurricane ties were not observed at attic area. These ties are needed to prevent damage during high winds. Consider
  having a competent framing carpenter further evaluate area correcting as needed.

  3. Wall Insulation


  Roll fiberglass

  Where visible

  4. Attic Insulation


  Blown


  In January 2006 attic insulation standards set by the Department of Energy for this part of the country were increased
  to R-49 to help lower energy use. Local minimum insulation requirements may be less than DOE standards and often
  are R-30.

  R-30 attic insulation observed

  Where compressed
  R-19 Attic Insulation - Insufficient insulation viewed in attic for this area. Consider adding attic insulation to R-30 or R-
  49 to lower utility costs.

  5. Attic ventilation


  Gable End Vent

  Soffit Vents

  Ridge Roof Vents




Roger Williamson                                         Page 9 of 29                          HomePro Inspection Inc
Rural 2007 Built                                                                          Photo distorted on purpose

                                                         Foundation
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  foundation. Foundation conditions requiring correction should be performed by a competent qualified
  contractor.

  1. Foundation Access


  Scuttle hole to crawl space

  Insulation Installed - Visibility limited due to installed insulation in this area.

  Installed ductwork in crawl space - Visibility or access limited in this area due to installed ductwork.

  2. Foundation
  Materials:

  Concrete block foundation walls
  Observations: Cracks Minor - Some cracks were noted that are minor in nature. Small settlement cracks are a
  common occurrence and can be repaired, providing that the settlement has stopped.

  3. Crawl Space Floor Framing
  Materials:

  No adverse conditions were observed

  Insulation Installed - Visibility limited due to installed insulation in this area.

  Floor Joist - Solid Wood

  Beam - Built-up Wood

  Column - Concrete Block

  Sub floor - OSB

  4. Floor Insulation


  Roll Fiberglass where installed at crawl space


  PERIODIC MAINTENANCE NEEDED

  Some insulation observed falling in crawl space
  Falling Insulation - Portions of the insulation are falling from their original position. Have the affected areas re-attached
  properly.

  5. Crawl Space Issues


  Construction Debris - Construction debris noted in crawl space. Remove debris and wood scraps from crawl space
  area. Do not forget to check beneath plastic sheeting on ground too if installed.

  6. Water Control Measures
  Observations: None observed
  Water Stains - Water stains were noted. Stains are evidence of prior water penetrations. Monitor and repair as needed
  Standing water was observed in crawl space. Further evaluation is needed to determine source of unwanted water.
  Take appropriate measures to prevent recurrence and properly correct affected areas as needed.



Roger Williamson                                           Page 10 of 29                      HomePro Inspection Inc
Rural 2007 Built                                                                  Photo distorted on purpose




    Standing water was observed in crawl space. Further     Water Stains - Water stains were noted. Stains are evidence
    evaluation is needed to determine source of unwanted     of prior water penetrations. Monitor and repair as needed
   water. Take appropriate measures to prevent recurrence
       and properly correct affected areas as needed.




Roger Williamson                                   Page 11 of 29                      HomePro Inspection Inc
Rural 2007 Built                                                                     Photo distorted on purpose

                                    Central Heating and Cooling
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  central heating and cooling systems. These systems are tested using the normal operating controls
  only. Improperly maintained heating and cooling can cause uncomfortable areas, higher utility bills
  and safety concerns. Heating and Cooling installation conditions and functional issues requiring
  correction should be performed by a competent licensed mechanical contractor.

  1. Installed Central Heating and Cooling

  • Central Heating and Cooling System 1     System serves main level

   Brand Furnace: Amana / Location: Exterior Package Unit / Fuel: Electric Heat Pump

   Size: 4 Ton / Date of Manufacture: 2007

   Heat pumps typically have a service life of 10-15 years when properly maintained


   Filter Type: Disposable / Thermostat Type: Digital


   Brand AC: Amana / Location: Exterior Package Unit / Fuel: Electric Heat Pump

   Size:4 ton / Date of Manufacture: 2007

   Central AC units typically have a service life of 10-15 years when properly maintained

   AC condensate disposal method: Gravity drain for condensate



  • Central Heating and Cooling System 2     System serves upstairs area

   Brand Furnace: Amana / Location: Attic / Fuel: Electric Heat Pump

   Size: 2.5 Ton / Date of Manufacture: 2007

   Heat pumps typically have a service life of 10-15 years when properly maintained


   Filter Type: Disposable / Thermostat Type: Digital


   Brand AC: Amana / Location: Exterior / Fuel: Electric Heat Pump

   Size:2.5 ton / Date of Manufacture: 2007

   Central AC units typically have a service life of 10-15 years when properly maintained

   AC condensate disposal method: Gravity drain piping - service annually



  2. Fuel
  Observations: NOTE TO CLIENT - gas logs viewed but not operated
  Gas appears off to dwelling - The gas service appears off or out of fuel to the dwelling. The inspector was unable to
  view any of the gas appliances in operation or check the pipes for gas leaks. Verify appliances functioning normally and
  no leaks are present prior to settlement.




Roger Williamson                                     Page 12 of 29                          HomePro Inspection Inc
Rural 2007 Built                                                                      Photo distorted on purpose

  3. Heating Function


  For both units

  Run in cool only - Due to outside air temp, the heat pump was checked in cooling mode only.

  4. AC Function


  For both units
  Downstairs unit appeared to be cooling some but not as designed.
  Upstairs unit was not cooling
  Properly put both systems back in service correcting as needed for function or safety.

  System was not cooling properly during inspection. System should be properly serviced correcting as needed for
  safety and function.

  5. Duct


  Metal and flexible duct installed

  Calculating load of central system - Several factors are considered when performing a load evaluation for central
  heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed
  ductwork, insulation, ceiling height, basement area served if present, shade, climate zone along with size, number and
  placement of windows have to be taken into account before sizing a system. Inspector does not calculate load during a
  home inspection.



  Ducts need cleaning - Some ducts appear dirty and are ready for cleaning.

  Ductwork Damaged - The inspector noted damage to the ductwork which requires repair. Check all ductwork and repair
  as needed.




   Ductwork Damaged - The inspector noted damage to the            Clean construction debris from installed duct work
    ductwork which requires repair. Check all ductwork and
                      repair as needed.




Roger Williamson                                      Page 13 of 29                        HomePro Inspection Inc
Rural 2007 Built                                                                  Photo distorted on purpose

  6. Furnace Location Issue


  Upstairs furnace does not have proper access and was only viewed from a distance by inspector. Consult a competent
  heating contractor correcting as needed.
  Irregular construction observed - The inspector recommends further evaluation and proper correction as needed for
  safety and function.




  Upstairs furnace does not have proper access and was only viewed from a distance by inspector. Consult a competent
                                        heating contractor correcting as needed.




Roger Williamson                                   Page 14 of 29                      HomePro Inspection Inc
Rural 2007 Built                                                                          Photo distorted on purpose

                                       Fireplace/ Space heat-cool
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  fireplaces, other solid fuel burning systems and permanently installed space heating and cooling
  systems as present. Any type of space heating equipment should be serviced annually and maintain
  proper clearance from combustibles year round. Any conditions requiring correction should be
  performed by a competent qualified contractor.

  1. Fireplace


  Fireplace use nonessential - Installed fireplace is not the sole heating system for this home and does not have to
  function if you do not desire to use the fireplace. Typically deficient fireplaces are not listed in the summary of the
  report. Properly repair fireplace if use desired.

  Fireplace #1
  Type: Wood Burning / Location: Living Room

  Damper Operated - The fireplace damper was opened and closed and functioned normally.

  Sooted - Fireplace and chimney were observed sooted. Both should be professionally cleaned and checked by
  chimney specialist prior to use.

  Fireplace #2
  Type: Gas Logs Installed - Ventless Prefabricated Firebox / Location: Master Bedroom
  Verify this gas appliance is approved for a sleeping area before use

  Isolation Valve - A gas isolation valve was not viewed at or near the inspected unit to fully shut off the gas when
  servicing unit or to leave unit off for an extended period of time. The inspector recommends properly adding an
  accessible gas isolation valve for safety.




Roger Williamson                                        Page 15 of 29                         HomePro Inspection Inc
Rural 2007 Built                                                                     Photo distorted on purpose

                                                     Electrical
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  electrical system. Electrical installation conditions and functional issues requiring correction should
  be performed by a competent licensed electrical contractor.

  1. Electrical Service


  Underground

  200 Amp Service

  2. Electrical Distribution
  Observations:

  200 Amps / 120/240 Volts / Breaker Panel
  Panel Location:At Meter

  Package heat pump is installed interfering with dedicated service access at exterior main breaker panel.
  Working Access - This equipment should have unobstructed access of no less than 30" in width and 36" depth as
  measured out from the inspected item. This clear area is needed for safe access to this type of equipment. Consider
  relocating equipment or obstruction as needed.

  3. Electrical Sub Panel
  Observations:

  200 Amps / 120/240 Volts / Breaker Panel
  Panel Location:Garage

  Panel Inspected - The cover was removed from the electrical panel. The interior components were viewed and found to
  be in satisfactory condition and appear to be properly installed. No repairs are needed to panel or interior components
  at this time.

  4. Electrical Branch Wiring


  Material: Nonmetallic-Sheathed Cable
  Observations:

  Unterminated wiring observed at exterior front yard.
  Unterminated exposed energized wiring observed at rear exterior patio.
  Unterminated wiring - Some wires viewed not terminated. Add wire nuts to all unterminated wiring in junction
  boxes/panel or otherwise properly terminate in junction box with cover as needed.

  Properly relocate wiring away from attic access as required for safety.
  Improper wiring - Improper wiring was noted. Have a qualified electrician check and repair as needed for function and
  safety.




Roger Williamson                                     Page 16 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                      Photo distorted on purpose




     Unterminated wiring observed at exterior front yard.       Unterminated exposed energized wiring observed at rear
                                                                                   exterior patio.




                           Properly relocate wiring away from attic access as required for safety.
  5. Electrical Receptacle Outlets


  Using a circuit tester, a representative number of grounding type electrical receptacles were randomly checked and
  correct wiring was indicated.

  PERIODIC MAINTENANCE NEEDED

  Missing cover plate -Install switch or receptacle cover plates where missing or damaged to reduce electrical hazard.

  6. Electrical GFCI
  Observations:

  GFCI Ok - Using a ground fault circuit interrupter (GFCI) tester, receptacles were checked and indicated properly
  function.




Roger Williamson                                      Page 17 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                     Photo distorted on purpose

  7. Electrical Lighting Outlets


  A representative number of installed lighting fixtures were observed and appeared to be generally serviceable within
  the parameters of their given service life.

  Not Observed - Street lights at end of drive

  8. Smoke Alarms


  PERIODIC MAINTENANCE NEEDED

  Check - Check smoke detectors regularly and no less than twice a year when time changes. Refer to installation and
  care instructions for proper locations and periodic maintenance.




Roger Williamson                                     Page 18 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                      Photo distorted on purpose

                                                      Plumbing
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  plumbing system. Plumbing installation conditions and functional issues requiring correction should
  be performed by a competent licensed plumbing contractor.

  .
   1. Supply Piping
  Flow:

  Adequate functional water flow observed


  The visible portions of water supply piping were found generally serviceable within the parameters of its given service
  life. No immediate repair concerns were observed.

  Material: Copper

  Material: PEX

  2. Waste Piping
  Flow:

  Functional waste water flow observed


  The visible portions of waste water piping were found generally serviceable within the parameters of its given service
  life. No immediate repair concerns were observed.

  3. Plumbing Equipment


  Water pressure acceptable - The water pressure was checked at an outlet located after the pressure reducer, if one
  was present. The pressure was found to be within the acceptable 40-80 PSI range. See any additional notes regarding
  functional water flow recorded under plumbing supply piping.

  Water pressure reducer was observed inside crawl space

  A water isolation valve was not observed near pressure reducing valve for servicing of pressure reducer. Consider
  installing isolation valve where missing.

  A sewage pump was noted. Obtain installation and warranty information. Such pumps should be accessible as they
  require periodic servicing and have high water alarms. It is outside the scope of the home inspection to remove the the
  sewage pump lid to verify the unit is functioning properly. Monitor this type of equipment servicing when necessary.



  The recirculation pump installed at water heater does not appear to be connected electrically
  Not Working - The inspected item is not operating properly. Properly repair as needed for function and safety.




Roger Williamson                                      Page 19 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                      Photo distorted on purpose




                  A sewage pump was noted.                      The recirculation pump installed at water heater does not
                                                                           appear to be connected electrically
  4. Electric Water Heater


  Typical service life of a water heater is 8-12 years.

  Location:

  Garage
  Size: Covered With Insulation - Water heater is covered with additional insulation over the tank and was not visible.
  Inspector was unable to determine size or age of water heater.


  Water heater was observed functional during home inspection




Roger Williamson                                          Page 20 of 29                    HomePro Inspection Inc
Rural 2007 Built                                                                     Photo distorted on purpose

                                                       Interior
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  interior including Walls, Ceilings, Floors, Steps, Stairways, Balconies, Railings, and Doors. Cosmetic
  issues are not addressed for these areas but significant physical damage, questionable staining and
  significant improper function are addressed in this inspection report. Conditions requiring correction
  for these areas should be performed by a competent qualified contractor.

  1. Walls


  Material: Drywall

  PERIODIC MAINTENANCE NEEDED

  Deferred Maintenance - The inspected item suffers from deferred maintenance and is ready for reconditioning.

  Cracks from expansion or settlement - Noticeable cracking was observed. This is not unusual. Monitor and properly
  repair as needed.

  Dining room crown trim and wall appear to have moisture damage. Verify cause of damage, take corrective measures
  to prevent recurrence and properly repair any affected areas.
  Stained - The material is stained. Some stains may be very difficult to remove. Before repairing, be sure the source of
  the stain has been located and cured.

  Dining room crown moulding
  Physical Damage - Physical damage was noted and should be properly repaired.




  Dining room crown trim and wall appear to have moisture damage. Verify cause of damage, take corrective measures to
                                 prevent recurrence and properly repair any affected areas.
  Stained - The material is stained. Some stains may be very difficult to remove. Before repairing, be sure the source of
                                           the stain has been located and cured.
  2. Ceilings


  Material: Drywall

  Cracks Minor - Some cracks were noted that are minor in nature. Small settlement cracks are a common occurrence
  and can be repaired, providing that the settlement has stopped.




Roger Williamson                                     Page 21 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                     Photo distorted on purpose

  3. Flooring


  Material:

  Carpet

  Wood

  Upstairs
  Incomplete - Typical scope of work for item inspected has not been completed. Additional work/repair should be
  properly performed to complete area.

  Right rear room
  Worn Flooring - The flooring shows wear and may be ready for replacement/refinishing soon.

  4. Doors
  Material:

  Wood

  Fiberboard

  PERIODIC MAINTENANCE NEEDED

  Minor adjustment needed - The inspected item is functional overall but requires minor routine adjustment for proper
  operation.

  5. Interior Steps


  No adverse conditions were observed

  Carpeted steps observed

  6. Railings


  No adverse conditions were observed

  7. Windows
  Materials:

  Vinyl

  A representative number of windows were operated and were found generally serviceable within the parameters of
  their given service life.

  8. Window Glazing


  Insulated glass observed at windows




Roger Williamson                                     Page 22 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                      Photo distorted on purpose

                                                        Kitchen
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  kitchen including counters and a representative number of cabinets. The following built in appliances
  are checked as part of this inspection report if present: Range, Cook top, Oven, Garbage Disposal,
  Microwave, Trash Compactor, Ventilation Equipment such as a Range Hood. Installed Dishwashers
  are run through a normal cycle. Appliance inspection does not cover clocks, timers, self cleaning
  function, calibration or automatic functions. Refrigerators are outside the scope of this inspection and
  only their presence or absence is noted. Installation conditions and functional issues for this area
  requiring correction should be performed by a competent qualified contractor.

  1. Countertop


  Countertop Acceptable - The countertop was inspected and found to be generally serviceable within the parameters of
  its given service life

  Material: Granite

  2. Cabinets


  Cabinets Acceptable - A representative number of built-in cabinets were inspected and found to be generally
  serviceable within the parameters of their given service life

  Material: Wood and Wood Composition

  Painted

  3. Sink and Faucet
  Observations: PERIODIC MAINTENANCE NEEDED
  Correct leak at aerator
  Double Bowl Composition

  4. Dishwasher


  Dishwasher Functional - The dishwasher was run through a normal wash cycle and appeared to be functioning.
  Additionally, no leaks were observed about the dishwasher during the inspection.

  Dishwasher service life - Typically dishwashers are designed to last approximately 10 years.

  PERIODIC MAINTENANCE NEEDED

  Refer to installation instructions properly securing dishwasher in place

  Incomplete - Typical scope of work for item inspected has not been completed. Additional work/repair should be
  properly performed to complete area.

  5. Microwave


  On/Off Tested - Inspected appliance was turned on and off by the normal operating controls. The main function of the
  appliance appeared to be operating normally. Inspector does not test calibration of appliances or check the function of
  optional equipment on appliances.

  Microwave - Permanently Installed
  Glass tray at bottom of microwave did not move during operation, correct if needed




Roger Williamson                                       Page 23 of 29                      HomePro Inspection Inc
Rural 2007 Built                                                                      Photo distorted on purpose

  6. Cooking Ventilation


  Above range integral with microwave

  Ductless



  15" deep cabinet above microwave blocks exhaust opening at top front of microwave.
  Exhaust observed obstructed and proper correction is needed.




  15" deep cabinet above microwave blocks exhaust opening at top front of microwave. Exhaust observed obstructed and
                                            proper correction is needed.
  7. Kitchen Floor
  Observations: No adverse conditions were observed
  Material: Wood

  8. Laundry Connections
  Observations:

  Washer and dryer connections are available but appliances were not present during inspection.



  Clothes dryer exhausts to an interior area The dryer should exhaust directly to exterior through a metal pipe to reduce
  moisture inside the home that could be detrimental to building components.

  9. Refrigerator
  A refrigerator was not present




Roger Williamson                                      Page 24 of 29                       HomePro Inspection Inc
Rural 2007 Built                                                                        Photo distorted on purpose

                                                         Bath 1
  The following opinion is based on an inspection of the readily accessible and visible portions of the
  bathrooms. Installation conditions and functional issues for this area requiring correction should be
  performed by a competent qualified contractor.

  1. Plumbing Fixtures


  LOCATION: Master Bath

  Installed Fixtures

  Bathing: Hydro massage tub and separate shower

  Sink: Two basins in vanity

  Toilet: Water tank type




  Hydro massage tub - The hydro massage tub was filled and tested. The unit was observed functioning normally.

  Sink Faucet
  No Leaks Observed - The inspected faucet was run for longer than one minute. No leaks were viewed at the visible
  supply lines, faucet or the visible waste drain lines just beneath the sink.

  Toilet
  Functional - The toilet was flushed no less than two times. On each operation the toilet refilled and shut off properly. No
  leaks were noted at toilet.

  PERIODIC MAINTENANCE NEEDED

  Shower floor tile are cracked and should be monitored or repaired
  Tile Cracked - Cracked tile were observed. This can be due to settlement or improper installation. Monitor area
  budgeting corrections if condition worsens.

  2. Ventilation Type


  Fan on/off tested - The bathroom vent fan was switched on and the sound heard appeared to be appropriate for the
  fan. It is beyond the scope of the home inspection to determine the effectiveness of the bathroom fan such as to verify
  air flow quantity or discharge location.

  3. Bath Floor
  Material:

  No adverse conditions were observed

  Material: Tile




Roger Williamson                                       Page 25 of 29                        HomePro Inspection Inc
Rural 2007 Built                                                                        Photo distorted on purpose

                                                          Bath 2
  1. Plumbing Fixtures


  LOCATION: Hall Bath

  Installed Fixtures

  Bathing: Hydro massage tub and separate shower

  Bathing Area Acceptable - The inspected faucet was run for no less than five minutes checking the tub and shower flow
  as present. No visible leaks were observed during the inspection and the water containment area appeared
  serviceable.


  Sink: Vanity with basin

  No Leaks Observed - The inspected faucet was run for longer than one minute. No leaks were viewed at the visible
  supply lines, faucet or the visible waste drain lines just beneath the sink.


  Toilet: Water tank type

  Toilet Functional - The toilet was flushed no less than two times. On each operation the toilet refilled and shut off
  properly. No leaks were noted at toilet.



  Hydro massage tub - The hydro massage tub was filled and tested. The unit was observed functioning normally.

  2. Ventilation Type
  Type:

  Fan on/off tested - The bathroom vent fan was switched on and the sound heard appeared to be appropriate for the
  fan. It is beyond the scope of the home inspection to determine the effectiveness of the bathroom fan such as to verify
  air flow quantity or discharge location.

  3. Bath Floor


  No adverse conditions were observed

  Material: Tile




Roger Williamson                                       Page 26 of 29                         HomePro Inspection Inc
Rural 2007 Built                                                                        Photo distorted on purpose

                                                          Bath 3
  1. Plumbing Fixtures


  LOCATION: Half Bath

  Installed Fixtures


  Sink: Vanity with basin

  No Leaks Observed - The inspected faucet was run for longer than one minute. No leaks were viewed at the visible
  supply lines, faucet or the visible waste drain lines just beneath the sink.


  Toilet: Water tank type

  Toilet Functional - The toilet was flushed no less than two times. On each operation the toilet refilled and shut off
  properly. No leaks were noted at toilet.


  2. Ventilation Type
  Type:

  Fan on/off tested - The bathroom vent fan was switched on and the sound heard appeared to be appropriate for the
  fan. It is beyond the scope of the home inspection to determine the effectiveness of the bathroom fan such as to verify
  air flow quantity or discharge location.

  3. Bath Floor
  Material:

  No adverse conditions were observed

  Material: Tile




Roger Williamson                                       Page 27 of 29                         HomePro Inspection Inc
Rural 2007 Built                                                                Photo distorted on purpose

 Report Summary
                                       Report Summary
  Outdoor Areas
  Page 4 Item: 7    Patio              All guard rails are less than 36" tall, hand rail at steps is ok at 34"
                                       Guardrails where required at elevated walk areas should be at least 36"
                                       tall for safety to help reduce falls. The installed guardrail is less than 36”
                                       tall. Evaluate your risk exposure correcting as needed for function or
                                       safety.

                                       Some spindle spacing is too wide
                                       Spindle Spacing – Railing spindles should be close together to help
                                       prevent falls or entrapment. Spindles should be constructed to reject a 4”
                                       sphere or ball being passed through the spindles. Evaluate your risk
                                       exposure and properly correct as needed for safety and function.
  Roofing
  Page 8 Item: 2    Roof Covering      Damaged shingles were observed
                                       Apparent moisture damage observed at dining room wall may or may not
                                       be related to roof condition.
                                       Roofing is ready for periodic maintenance. Have a qualified competent
                                       contractor check entire roof system and associated flashings. Repair or
                                       replace affected areas as needed.
  Foundation
  Page 10 Item: 5   Crawl Space        Construction Debris - Construction debris noted in crawl space. Remove
                    Issues             debris and wood scraps from crawl space area. Do not forget to check
                                       beneath plastic sheeting on ground too if installed.
  Page 11 Item: 6   Water Control      None observed
                    Measures           Water Stains - Water stains were noted. Stains are evidence of prior water
                                       penetrations. Monitor and repair as needed
                                       Standing water was observed in crawl space. Further evaluation is needed
                                       to determine source of unwanted water. Take appropriate measures to
                                       prevent recurrence and properly correct affected areas as needed.
  Central Heating and Cooling
  Page 12 Item: 2 Fuel                 NOTE TO CLIENT - gas logs viewed but not operated
                                       Gas appears off to dwelling - The gas service appears off or out of fuel to
                                       the dwelling. The inspector was unable to view any of the gas appliances
                                       in operation or check the pipes for gas leaks. Verify appliances functioning
                                       normally and no leaks are present prior to settlement.
  Page 13 Item: 4   AC Function        For both units
                                       Downstairs unit appeared to be cooling some but not as designed.
                                       Upstairs unit was not cooling
                                       Properly put both systems back in service correcting as needed for
                                       function or safety.

                                       System was not cooling properly during inspection. System should be
                                       properly serviced correcting as needed for safety and function.
  Page 13 Item: 5   Duct               Ducts need cleaning - Some ducts appear dirty and are ready for cleaning.

                                       Ductwork Damaged - The inspector noted damage to the ductwork which
                                       requires repair. Check all ductwork and repair as needed.
  Page 14 Item: 6   Furnace Location   Upstairs furnace does not have proper access and was only viewed from a
                    Issue              distance by inspector. Consult a competent heating contractor correcting
                                       as needed.
                                       Irregular construction observed - The inspector recommends further
                                       evaluation and proper correction as needed for safety and function.
  Electrical




Roger Williamson                             Page 28 of 29                          HomePro Inspection Inc
Rural 2007 Built                                                                 Photo distorted on purpose

  Page 17 Item: 4   Electrical Branch     Unterminated wiring observed at exterior front yard.
                    Wiring                Unterminated exposed energized wiring observed at rear exterior patio.
                                          Unterminated wiring - Some wires viewed not terminated. Add wire nuts to
                                          all unterminated wiring in junction boxes/panel or otherwise properly
                                          terminate in junction box with cover as needed.

                                          Properly relocate wiring away from attic access as required for safety.
                                          Improper wiring - Improper wiring was noted. Have a qualified electrician
                                          check and repair as needed for function and safety.
  Plumbing
  Page 20 Item: 3   Plumbing              The recirculation pump installed at water heater does not appear to be
                    Equipment             connected electrically
                                          Not Working - The inspected item is not operating properly. Properly
                                          repair as needed for function and safety.
  Kitchen
  Page 24 Item: 6   Cooking Ventilation 15" deep cabinet above microwave blocks exhaust opening at top front of
                                          microwave.
                                          Exhaust observed obstructed and proper correction is needed.
  Page 24 Item: 8   Laundry               Clothes dryer exhausts to an interior area The dryer should exhaust
                    Connections           directly to exterior through a metal pipe to reduce moisture inside the
                                          home that could be detrimental to building components.




Roger Williamson                                Page 29 of 29                        HomePro Inspection Inc

More Related Content

What's hot

What's hot (15)

Industrial inspection sample report
Industrial inspection sample reportIndustrial inspection sample report
Industrial inspection sample report
 
Sample Residential Inspection Report
Sample Residential Inspection ReportSample Residential Inspection Report
Sample Residential Inspection Report
 
Sample Home Inspection Report
Sample Home Inspection ReportSample Home Inspection Report
Sample Home Inspection Report
 
Texas rei7 2 pier & beam sample report
Texas rei7 2 pier & beam sample reportTexas rei7 2 pier & beam sample report
Texas rei7 2 pier & beam sample report
 
Sample report
Sample reportSample report
Sample report
 
A thru Z Inspections Sample Report 2010
A thru Z Inspections Sample Report 2010A thru Z Inspections Sample Report 2010
A thru Z Inspections Sample Report 2010
 
Demo Report.PDF
Demo Report.PDFDemo Report.PDF
Demo Report.PDF
 
Apex sample report
Apex sample reportApex sample report
Apex sample report
 
Sample report residential 1[1]
Sample report residential 1[1]Sample report residential 1[1]
Sample report residential 1[1]
 
Hiring A Home Inspector (Cmhc)
Hiring A Home Inspector (Cmhc)Hiring A Home Inspector (Cmhc)
Hiring A Home Inspector (Cmhc)
 
Sample Report
Sample ReportSample Report
Sample Report
 
New Home Inspection Sample Report
New Home Inspection Sample ReportNew Home Inspection Sample Report
New Home Inspection Sample Report
 
Sample RS 6-10-15
Sample RS 6-10-15Sample RS 6-10-15
Sample RS 6-10-15
 
Sample Home Inspection Report
Sample Home Inspection ReportSample Home Inspection Report
Sample Home Inspection Report
 
Full House Inspections Sample Report
Full House Inspections Sample ReportFull House Inspections Sample Report
Full House Inspections Sample Report
 

Viewers also liked

B.sc. nursing college in delhi
B.sc. nursing college in delhiB.sc. nursing college in delhi
B.sc. nursing college in delhiITSWS Technologies
 
Prospectus 2016-2017
Prospectus 2016-2017Prospectus 2016-2017
Prospectus 2016-2017N_8576
 
Professional and Regulating Body in Nursing
Professional and Regulating Body in NursingProfessional and Regulating Body in Nursing
Professional and Regulating Body in NursingSwastik Mulay
 
Nursing regulatory mechanisms
Nursing regulatory mechanismsNursing regulatory mechanisms
Nursing regulatory mechanismsJORRY POULOSE
 
India Nursing Council, State Nursing Council, Nursing board & University
India Nursing Council, State Nursing Council, Nursing board & UniversityIndia Nursing Council, State Nursing Council, Nursing board & University
India Nursing Council, State Nursing Council, Nursing board & UniversitySujata Mohapatra
 
Management of school of nursing
Management of school of nursingManagement of school of nursing
Management of school of nursingEko Priyanto
 
historical development of nursing research
historical development of nursing researchhistorical development of nursing research
historical development of nursing researchJolly George
 
Regulatory bodies and legal aspects in nursing
Regulatory bodies and legal aspects in nursingRegulatory bodies and legal aspects in nursing
Regulatory bodies and legal aspects in nursingJenita John
 
nursing educational institution planning,organizing, formulation of philosophys
nursing educational institution planning,organizing, formulation of philosophysnursing educational institution planning,organizing, formulation of philosophys
nursing educational institution planning,organizing, formulation of philosophysmohammed rafi
 
Administrative Organization of a College of Nursing
Administrative Organization of a College of Nursing Administrative Organization of a College of Nursing
Administrative Organization of a College of Nursing danilojrolaer99
 
Administration of nursing curriculum
Administration of nursing curriculumAdministration of nursing curriculum
Administration of nursing curriculumKavya Raju
 
Nursing Curriculum Development
Nursing Curriculum DevelopmentNursing Curriculum Development
Nursing Curriculum DevelopmentJofred Martinez
 
Code of ethics ppt
Code of ethics pptCode of ethics ppt
Code of ethics pptaneez103
 

Viewers also liked (15)

B.sc. nursing college in delhi
B.sc. nursing college in delhiB.sc. nursing college in delhi
B.sc. nursing college in delhi
 
Prospectus 2016-2017
Prospectus 2016-2017Prospectus 2016-2017
Prospectus 2016-2017
 
Professional and Regulating Body in Nursing
Professional and Regulating Body in NursingProfessional and Regulating Body in Nursing
Professional and Regulating Body in Nursing
 
Nursing regulatory mechanisms
Nursing regulatory mechanismsNursing regulatory mechanisms
Nursing regulatory mechanisms
 
India Nursing Council, State Nursing Council, Nursing board & University
India Nursing Council, State Nursing Council, Nursing board & UniversityIndia Nursing Council, State Nursing Council, Nursing board & University
India Nursing Council, State Nursing Council, Nursing board & University
 
Management of school of nursing
Management of school of nursingManagement of school of nursing
Management of school of nursing
 
historical development of nursing research
historical development of nursing researchhistorical development of nursing research
historical development of nursing research
 
Regulatory bodies and legal aspects in nursing
Regulatory bodies and legal aspects in nursingRegulatory bodies and legal aspects in nursing
Regulatory bodies and legal aspects in nursing
 
nursing educational institution planning,organizing, formulation of philosophys
nursing educational institution planning,organizing, formulation of philosophysnursing educational institution planning,organizing, formulation of philosophys
nursing educational institution planning,organizing, formulation of philosophys
 
School Nursing
School NursingSchool Nursing
School Nursing
 
Administrative Organization of a College of Nursing
Administrative Organization of a College of Nursing Administrative Organization of a College of Nursing
Administrative Organization of a College of Nursing
 
Planning of Nursing Unit
Planning of Nursing UnitPlanning of Nursing Unit
Planning of Nursing Unit
 
Administration of nursing curriculum
Administration of nursing curriculumAdministration of nursing curriculum
Administration of nursing curriculum
 
Nursing Curriculum Development
Nursing Curriculum DevelopmentNursing Curriculum Development
Nursing Curriculum Development
 
Code of ethics ppt
Code of ethics pptCode of ethics ppt
Code of ethics ppt
 

Similar to Sample 2007 built_rural_area

Sample carbon monoxide_issue
Sample carbon monoxide_issueSample carbon monoxide_issue
Sample carbon monoxide_issueHomePro4214913
 
Home inspection-agreement
Home inspection-agreementHome inspection-agreement
Home inspection-agreementgreeninspector
 
Our inspection agreement
Our inspection agreementOur inspection agreement
Our inspection agreementstoneybrook
 
Texas rei7 2 john doe sample report
Texas rei7 2 john doe sample reportTexas rei7 2 john doe sample report
Texas rei7 2 john doe sample reportcommercialnetinc
 
Inspection agreement page
Inspection agreement pageInspection agreement page
Inspection agreement pageWarren Porter
 
Sample Report PREM Sample town (10)
Sample Report PREM Sample town (10)Sample Report PREM Sample town (10)
Sample Report PREM Sample town (10)Tom Esprester
 
Home Condition Survey
Home Condition SurveyHome Condition Survey
Home Condition SurveyPeter Onipe
 
Accurateinspections sample-report
Accurateinspections sample-reportAccurateinspections sample-report
Accurateinspections sample-reportDoncrook
 
2700 graceland st chevy chase md 20800
2700 graceland st chevy chase md 208002700 graceland st chevy chase md 20800
2700 graceland st chevy chase md 20800Andrew Ling
 
Pre insp contract
Pre insp contractPre insp contract
Pre insp contractbuyersally
 
Sample Home Inspection Report.pdf
Sample Home Inspection Report.pdfSample Home Inspection Report.pdf
Sample Home Inspection Report.pdfTaylor585574
 
Capital Needs Assessment Example
Capital Needs Assessment ExampleCapital Needs Assessment Example
Capital Needs Assessment ExampleAdam Hoeksema
 
Visual Building Inspection Report - House Check NSW
Visual Building Inspection Report - House Check NSWVisual Building Inspection Report - House Check NSW
Visual Building Inspection Report - House Check NSWHouse Check NSW
 

Similar to Sample 2007 built_rural_area (20)

Sample carbon monoxide_issue
Sample carbon monoxide_issueSample carbon monoxide_issue
Sample carbon monoxide_issue
 
All-Star Home Inspections Sample Report
All-Star Home Inspections Sample ReportAll-Star Home Inspections Sample Report
All-Star Home Inspections Sample Report
 
Sample report
Sample reportSample report
Sample report
 
Standard House
Standard HouseStandard House
Standard House
 
TMP20150425-01
TMP20150425-01TMP20150425-01
TMP20150425-01
 
Condominium sample report
Condominium sample reportCondominium sample report
Condominium sample report
 
Building Dilapidations International Sample Report with Gauge
Building Dilapidations International Sample Report with GaugeBuilding Dilapidations International Sample Report with Gauge
Building Dilapidations International Sample Report with Gauge
 
Home inspection-agreement
Home inspection-agreementHome inspection-agreement
Home inspection-agreement
 
Our inspection agreement
Our inspection agreementOur inspection agreement
Our inspection agreement
 
Texas rei7 2 john doe sample report
Texas rei7 2 john doe sample reportTexas rei7 2 john doe sample report
Texas rei7 2 john doe sample report
 
Inspection agreement page
Inspection agreement pageInspection agreement page
Inspection agreement page
 
Sample Report PREM Sample town (10)
Sample Report PREM Sample town (10)Sample Report PREM Sample town (10)
Sample Report PREM Sample town (10)
 
Home Condition Survey
Home Condition SurveyHome Condition Survey
Home Condition Survey
 
Accurateinspections sample-report
Accurateinspections sample-reportAccurateinspections sample-report
Accurateinspections sample-report
 
2700 graceland st chevy chase md 20800
2700 graceland st chevy chase md 208002700 graceland st chevy chase md 20800
2700 graceland st chevy chase md 20800
 
Pre insp contract
Pre insp contractPre insp contract
Pre insp contract
 
Sample Report
Sample ReportSample Report
Sample Report
 
Sample Home Inspection Report.pdf
Sample Home Inspection Report.pdfSample Home Inspection Report.pdf
Sample Home Inspection Report.pdf
 
Capital Needs Assessment Example
Capital Needs Assessment ExampleCapital Needs Assessment Example
Capital Needs Assessment Example
 
Visual Building Inspection Report - House Check NSW
Visual Building Inspection Report - House Check NSWVisual Building Inspection Report - House Check NSW
Visual Building Inspection Report - House Check NSW
 

Recently uploaded

The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxheathfieldcps1
 
9548086042 for call girls in Indira Nagar with room service
9548086042  for call girls in Indira Nagar  with room service9548086042  for call girls in Indira Nagar  with room service
9548086042 for call girls in Indira Nagar with room servicediscovermytutordmt
 
Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionSafetyChain Software
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationnomboosow
 
Measures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDMeasures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDThiyagu K
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Sapana Sha
 
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...Pooja Nehwal
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docxPoojaSen20
 
social pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajansocial pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajanpragatimahajan3
 
APM Welcome, APM North West Network Conference, Synergies Across Sectors
APM Welcome, APM North West Network Conference, Synergies Across SectorsAPM Welcome, APM North West Network Conference, Synergies Across Sectors
APM Welcome, APM North West Network Conference, Synergies Across SectorsAssociation for Project Management
 
Z Score,T Score, Percential Rank and Box Plot Graph
Z Score,T Score, Percential Rank and Box Plot GraphZ Score,T Score, Percential Rank and Box Plot Graph
Z Score,T Score, Percential Rank and Box Plot GraphThiyagu K
 
Sports & Fitness Value Added Course FY..
Sports & Fitness Value Added Course FY..Sports & Fitness Value Added Course FY..
Sports & Fitness Value Added Course FY..Disha Kariya
 
1029 - Danh muc Sach Giao Khoa 10 . pdf
1029 -  Danh muc Sach Giao Khoa 10 . pdf1029 -  Danh muc Sach Giao Khoa 10 . pdf
1029 - Danh muc Sach Giao Khoa 10 . pdfQucHHunhnh
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformChameera Dedduwage
 
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...Sapna Thakur
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdfQucHHunhnh
 
Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)eniolaolutunde
 
Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Celine George
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactPECB
 

Recently uploaded (20)

The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptx
 
9548086042 for call girls in Indira Nagar with room service
9548086042  for call girls in Indira Nagar  with room service9548086042  for call girls in Indira Nagar  with room service
9548086042 for call girls in Indira Nagar with room service
 
Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory Inspection
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communication
 
Measures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDMeasures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SD
 
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111Call Girls in Dwarka Mor Delhi Contact Us 9654467111
Call Girls in Dwarka Mor Delhi Contact Us 9654467111
 
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docx
 
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptxINDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
 
social pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajansocial pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajan
 
APM Welcome, APM North West Network Conference, Synergies Across Sectors
APM Welcome, APM North West Network Conference, Synergies Across SectorsAPM Welcome, APM North West Network Conference, Synergies Across Sectors
APM Welcome, APM North West Network Conference, Synergies Across Sectors
 
Z Score,T Score, Percential Rank and Box Plot Graph
Z Score,T Score, Percential Rank and Box Plot GraphZ Score,T Score, Percential Rank and Box Plot Graph
Z Score,T Score, Percential Rank and Box Plot Graph
 
Sports & Fitness Value Added Course FY..
Sports & Fitness Value Added Course FY..Sports & Fitness Value Added Course FY..
Sports & Fitness Value Added Course FY..
 
1029 - Danh muc Sach Giao Khoa 10 . pdf
1029 -  Danh muc Sach Giao Khoa 10 . pdf1029 -  Danh muc Sach Giao Khoa 10 . pdf
1029 - Danh muc Sach Giao Khoa 10 . pdf
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy Reform
 
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
BAG TECHNIQUE Bag technique-a tool making use of public health bag through wh...
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
 
Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)
 
Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global Impact
 

Sample 2007 built_rural_area

  • 1. HomePro Inspection Inc Knowledge Experience Integrity Cover Page PROPERTY INSPECTION REPORT Thank you for trusting me to perform your inspection so that you may Know What I See! Photo distorted on purpose, 30728 Inspection prepared for: Rural 2007 Built Inspection Date: 4/1/2011 Time: 1:00 PM Age: Built 2007 Size: 3300 Sqft Weather: Clear Inspector: Roger Williamson License # 226 TN - ASHI Certified Member # 204213 - Proud Member BBB 2409 Haven Crest Dr, Chattanooga, TN, 37421 Phone: 423-421-4913 Email: HomeProInspection@EPBFI.com www.HomeProInspection.com HomePro Inspection Inc 423-421-4913 ________________For Photo Integrity, Please Do Not Fax This Report
  • 2. Rural 2007 Built Photo distorted on purpose INSPECTION AGREEMENT Major Structural and Electromechanical Inspection COMPANY agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the American Society of Home Inspectors (ASHI) and the State of Tennessee STANDARDS. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable. The written report will include the following only: * general exterior, including roof, siding, windows, chimney, drainage and grading * structural condition of foundation &frame * electrical, plumbing, hot water heater, heating and air conditioning * general interior, including ceilings, walls, floors, windows, insulation and ventilation Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspectors opinions. It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. Detached structures are not included. The COMPANY will be under no obligation under any circumstances for any further follow- up inspection. ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done. This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process. The parties agree that the COMPANY, and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE COMPANY IS NOT AN INSURER OF ANY INSPECTED CONDITIONS. It is understood and agreed that should COMPANY and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of COMPANY and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report. The parties agree that the faxed copy of the agreement is to be relied upon in lieu of the original. Roger T. Williamson Roger T Williamson ASHI Certified Member # 204213 TN License # 226 Proud Member of the BBB Roger Williamson Page 1 of 29 HomePro Inspection Inc
  • 3. Rural 2007 Built Photo distorted on purpose HOW TO READ THIS REPORT This report is prepared with digital photos and therefore a faxed copy is not equivalent to the original and should not be utilized. The inspector when allowed posts the Home Inspection Report for download to the website www.HomeProInspection.com. This report is prepared using the Standards of Practice set forth by The American Society of Home Inspectors and The Tennessee Department of Commerce. A full copy of these standards is available at their respective websites: ASHI.org and Tennessee.gov. This report lists and describes specific attributes about the inspected property. Throughout the report you will find information regarding maintenance, upgrades or repairs that you should consider and act on when appropriate. PHOTOS Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. SUMMARY For convenience the report contains a summary. You should evaluate your risk exposure for the items listed here and appropriately schedule proper repairs by qualified competent contractors. Occasionally the inspector may also include a reminder NOTE TO CLIENT in the summary to let you know to obtain certain documentation or if the utilities were off during the inspection. ACCEPTABLE In the body of the report you will see items listed as ACCEPTABLE. This term is used for items that are typically stationary, non mechanical and considered generally serviceable within the parameters of their given service life. Cosmetic appearance is not taken into account when rating an item as Acceptable. HAZARDOUS Items listed as hazardous pose imminent danger to the inspected property or occupants. Hazardous situations should be properly corrected by qualified competent contractors before occupying the property. PERIODIC MAINTENANCE NEEDED In the body of the report you may see items listed as PERIODIC MAINTENANCE NEEDED. These items are not unusual for the type and age property inspected. Some of these items may be recurring maintenance that has been postponed. You should evaluate your risk exposure for the items listed here and appropriately schedule proper repairs by qualified competent contractors. MONITOR In the body of the report you may see items listed as MONITOR. Typically these are items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. PRE-DATE In the body of the report you may see items listed as PRE-DATE. These items or areas are where construction may have been completed before the current safety standards were in place or in some cases where local code variances may exist. You should evaluate your risk and liability exposure for these items or areas and consider upgrading for safety or function. Roger Williamson Page 2 of 29 HomePro Inspection Inc
  • 4. Rural 2007 Built Photo distorted on purpose Outdoor Areas The following opinion is based on an inspection of the readily accessible and visible portions of the outdoor areas. Any exterior conditions requiring correction should be performed by a competent qualified contractor. 1. Site Sloping Adjust Grade - Some landscape grade work may improve storm water run off away from foundation. Slope grade minimum ten feet away from and around structure so that water does not collect at home. 2. Vegetation Grass, shrubs and trees near dwelling were observed No adverse conditions were observed 3. Driveway Material: Concrete Cracks expansion/settlement - Noticeable cracking was observed. This is not unusual. Monitor and repair as needed. 4. Walkway Observations: Concrete Cracked Acceptable 5. Exterior Stairs Observations: Brick No adverse conditions were observed 6. Porch Material: Tile Covered No adverse conditions were observed Roger Williamson Page 3 of 29 HomePro Inspection Inc
  • 5. Rural 2007 Built Photo distorted on purpose 7. Patio Tile Water appears to pond at rear patio. Monitor area brooming after rains or correct to meet your needs. All guard rails are less than 36" tall, hand rail at steps is ok at 34" Guardrails where required at elevated walk areas should be at least 36" tall for safety to help reduce falls. The installed guardrail is less than 36” tall. Evaluate your risk exposure correcting as needed for function or safety. Some spindle spacing is too wide Spindle Spacing – Railing spindles should be close together to help prevent falls or entrapment. Spindles should be constructed to reject a 4” sphere or ball being passed through the spindles. Evaluate your risk exposure and properly correct as needed for safety and function. Roger Williamson Page 4 of 29 HomePro Inspection Inc
  • 6. Rural 2007 Built Photo distorted on purpose Exterior The following opinion is based on an inspection of the readily accessible and visible portions of the exterior and exterior surfaces of the structure. Any exterior conditions requiring correction should be performed by a competent qualified contractor. 1. Exterior Entry Doors Material: Metal Clad Fiberglass No adverse conditions were observed 2. Soffit Material: Vinyl soffits with metal fascia The exterior of the home was inspected and the eaves appears to be in overall good condition. No immediate repairs are needed at this time. 3. Siding - Masonry Brick Veneer PERIODIC MAINTENANCE NEEDED Cracks Minor - Some cracks were noted that are minor in nature. Small settlement cracks are a common occurrence and can be repaired, providing that the settlement has stopped. Brick size hole observed at right exterior Incomplete - Typical scope of work for item inspected has not been completed. Additional work/repair should be properly performed to complete area. Brick size hole observed Roger Williamson Page 5 of 29 HomePro Inspection Inc
  • 7. Rural 2007 Built Photo distorted on purpose 4. Trim Material: Wood where installed Repainting new homes - All painted exterior surfaces subject to decay on newer homes should be properly cleaned, caulked and repainted within the first three years after the home is built to preserve these components. Subsequent paintings are typically scheduled every 8-10 yrs. 5. Covered Parking Condition Attached Garage Installed drywall was observed on the garage ceiling framing. This offers some protection against the spread of fire from the garage to other areas. Installed drywall was observed on the walls that separate the garage and living space framing. This offers some protection against the spread of fire from the garage to other areas. Cracks expansion/settlement - Noticeable cracking was observed. This is not unusual. Monitor and repair as needed. 6. Garage Overhead Door Metal Sectional Insulated Garage overhead door was tested using electric operator. 7. Garage Overhead Door Operator Electric Operator Both units Non-Contact Reversal Satisfactory - The electronic eye of the operator was tested and found to be functioning normally. PERIODIC MAINTENANCE NEEDED Both units Contact Reversal Failed - The contact reversal was tested using a 1.5 inch obstruction on the floor at the center of the door. The operator pinned the obstruction without reversing. Adjust the force of the operator or the door mechanics as needed for proper operation and safety. Roger Williamson Page 6 of 29 HomePro Inspection Inc
  • 8. Rural 2007 Built Photo distorted on purpose Roofing The following opinion is based on an inspection of the readily accessible and visible portions of the roof on the day of inspection. This inspection is not a warranty of the roof system or a determination of how long it may be water tight. Any roof conditions requiring correction should be performed by a competent qualified contractor. 1. Access/Weather Access: Inspector walked portions of roofing Weather was clear during inspection Estimated Age 2-5 Years old Style of roofing Hip Gable Monitor irregular roof slope details correcting when necessary 2. Roof Covering Type of roofing installed Composition Shingle Metal Damaged shingles were observed Apparent moisture damage observed at dining room wall may or may not be related to roof condition. Roofing is ready for periodic maintenance. Have a qualified competent contractor check entire roof system and associated flashings. Repair or replace affected areas as needed. Monitor irregular roof sloping Monitor irregular roof sloping Roger Williamson Page 7 of 29 HomePro Inspection Inc
  • 9. Rural 2007 Built Photo distorted on purpose Damaged shingle Damaged shingle 3. Roof Penetration Plumbing Vents - MONITOR this type of penetration as the gasket about the plumbing waste pipe penetrating the roof requires periodic maintenance. Budget replacement of plumbing vent gaskets as they begin to split. This is needed each 8-10 years after the roof is installed. 4. Flashing Metal where visible 5. Gutters / Downspouts Material: Metal Discharge Underground - One or more downspouts are discharging into a below grade drainage system. The drainage system is inaccessible and therefore not inspected. PERIODIC MAINTENANCE NEEDED Discharge near foundation - Downspouts are discharging close to the foundation. This may cause water to enter the building. It is recommended that all downspouts be extended to allow water to flow quickly away from and around structure. Correct as needed. Clean Gutters - The gutters were viewed with debris in them and some downspouts may be obstructed. Although this is a maintenance item, the condition viewed may cause damage to the soffits or fascia and should be corrected soon. PERIODIC MAINTENANCE NEEDED 6. Chimney Materials: Top of chimney was not accessed by inspector Roger Williamson Page 8 of 29 HomePro Inspection Inc
  • 10. Rural 2007 Built Photo distorted on purpose Attic The following opinion is based on an inspection of the readily accessible and visible portions of the attic. Attic conditions requiring correction should be performed by a competent qualified contractor. 1. Attic Access Scuttle hole to attic 2. Attic Framing Wooden Rafters MONITOR or correct Hurricane ties were not observed at attic area. These ties are needed to prevent damage during high winds. Consider having a competent framing carpenter further evaluate area correcting as needed. 3. Wall Insulation Roll fiberglass Where visible 4. Attic Insulation Blown In January 2006 attic insulation standards set by the Department of Energy for this part of the country were increased to R-49 to help lower energy use. Local minimum insulation requirements may be less than DOE standards and often are R-30. R-30 attic insulation observed Where compressed R-19 Attic Insulation - Insufficient insulation viewed in attic for this area. Consider adding attic insulation to R-30 or R- 49 to lower utility costs. 5. Attic ventilation Gable End Vent Soffit Vents Ridge Roof Vents Roger Williamson Page 9 of 29 HomePro Inspection Inc
  • 11. Rural 2007 Built Photo distorted on purpose Foundation The following opinion is based on an inspection of the readily accessible and visible portions of the foundation. Foundation conditions requiring correction should be performed by a competent qualified contractor. 1. Foundation Access Scuttle hole to crawl space Insulation Installed - Visibility limited due to installed insulation in this area. Installed ductwork in crawl space - Visibility or access limited in this area due to installed ductwork. 2. Foundation Materials: Concrete block foundation walls Observations: Cracks Minor - Some cracks were noted that are minor in nature. Small settlement cracks are a common occurrence and can be repaired, providing that the settlement has stopped. 3. Crawl Space Floor Framing Materials: No adverse conditions were observed Insulation Installed - Visibility limited due to installed insulation in this area. Floor Joist - Solid Wood Beam - Built-up Wood Column - Concrete Block Sub floor - OSB 4. Floor Insulation Roll Fiberglass where installed at crawl space PERIODIC MAINTENANCE NEEDED Some insulation observed falling in crawl space Falling Insulation - Portions of the insulation are falling from their original position. Have the affected areas re-attached properly. 5. Crawl Space Issues Construction Debris - Construction debris noted in crawl space. Remove debris and wood scraps from crawl space area. Do not forget to check beneath plastic sheeting on ground too if installed. 6. Water Control Measures Observations: None observed Water Stains - Water stains were noted. Stains are evidence of prior water penetrations. Monitor and repair as needed Standing water was observed in crawl space. Further evaluation is needed to determine source of unwanted water. Take appropriate measures to prevent recurrence and properly correct affected areas as needed. Roger Williamson Page 10 of 29 HomePro Inspection Inc
  • 12. Rural 2007 Built Photo distorted on purpose Standing water was observed in crawl space. Further Water Stains - Water stains were noted. Stains are evidence evaluation is needed to determine source of unwanted of prior water penetrations. Monitor and repair as needed water. Take appropriate measures to prevent recurrence and properly correct affected areas as needed. Roger Williamson Page 11 of 29 HomePro Inspection Inc
  • 13. Rural 2007 Built Photo distorted on purpose Central Heating and Cooling The following opinion is based on an inspection of the readily accessible and visible portions of the central heating and cooling systems. These systems are tested using the normal operating controls only. Improperly maintained heating and cooling can cause uncomfortable areas, higher utility bills and safety concerns. Heating and Cooling installation conditions and functional issues requiring correction should be performed by a competent licensed mechanical contractor. 1. Installed Central Heating and Cooling • Central Heating and Cooling System 1 System serves main level Brand Furnace: Amana / Location: Exterior Package Unit / Fuel: Electric Heat Pump Size: 4 Ton / Date of Manufacture: 2007 Heat pumps typically have a service life of 10-15 years when properly maintained Filter Type: Disposable / Thermostat Type: Digital Brand AC: Amana / Location: Exterior Package Unit / Fuel: Electric Heat Pump Size:4 ton / Date of Manufacture: 2007 Central AC units typically have a service life of 10-15 years when properly maintained AC condensate disposal method: Gravity drain for condensate • Central Heating and Cooling System 2 System serves upstairs area Brand Furnace: Amana / Location: Attic / Fuel: Electric Heat Pump Size: 2.5 Ton / Date of Manufacture: 2007 Heat pumps typically have a service life of 10-15 years when properly maintained Filter Type: Disposable / Thermostat Type: Digital Brand AC: Amana / Location: Exterior / Fuel: Electric Heat Pump Size:2.5 ton / Date of Manufacture: 2007 Central AC units typically have a service life of 10-15 years when properly maintained AC condensate disposal method: Gravity drain piping - service annually 2. Fuel Observations: NOTE TO CLIENT - gas logs viewed but not operated Gas appears off to dwelling - The gas service appears off or out of fuel to the dwelling. The inspector was unable to view any of the gas appliances in operation or check the pipes for gas leaks. Verify appliances functioning normally and no leaks are present prior to settlement. Roger Williamson Page 12 of 29 HomePro Inspection Inc
  • 14. Rural 2007 Built Photo distorted on purpose 3. Heating Function For both units Run in cool only - Due to outside air temp, the heat pump was checked in cooling mode only. 4. AC Function For both units Downstairs unit appeared to be cooling some but not as designed. Upstairs unit was not cooling Properly put both systems back in service correcting as needed for function or safety. System was not cooling properly during inspection. System should be properly serviced correcting as needed for safety and function. 5. Duct Metal and flexible duct installed Calculating load of central system - Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served if present, shade, climate zone along with size, number and placement of windows have to be taken into account before sizing a system. Inspector does not calculate load during a home inspection. Ducts need cleaning - Some ducts appear dirty and are ready for cleaning. Ductwork Damaged - The inspector noted damage to the ductwork which requires repair. Check all ductwork and repair as needed. Ductwork Damaged - The inspector noted damage to the Clean construction debris from installed duct work ductwork which requires repair. Check all ductwork and repair as needed. Roger Williamson Page 13 of 29 HomePro Inspection Inc
  • 15. Rural 2007 Built Photo distorted on purpose 6. Furnace Location Issue Upstairs furnace does not have proper access and was only viewed from a distance by inspector. Consult a competent heating contractor correcting as needed. Irregular construction observed - The inspector recommends further evaluation and proper correction as needed for safety and function. Upstairs furnace does not have proper access and was only viewed from a distance by inspector. Consult a competent heating contractor correcting as needed. Roger Williamson Page 14 of 29 HomePro Inspection Inc
  • 16. Rural 2007 Built Photo distorted on purpose Fireplace/ Space heat-cool The following opinion is based on an inspection of the readily accessible and visible portions of the fireplaces, other solid fuel burning systems and permanently installed space heating and cooling systems as present. Any type of space heating equipment should be serviced annually and maintain proper clearance from combustibles year round. Any conditions requiring correction should be performed by a competent qualified contractor. 1. Fireplace Fireplace use nonessential - Installed fireplace is not the sole heating system for this home and does not have to function if you do not desire to use the fireplace. Typically deficient fireplaces are not listed in the summary of the report. Properly repair fireplace if use desired. Fireplace #1 Type: Wood Burning / Location: Living Room Damper Operated - The fireplace damper was opened and closed and functioned normally. Sooted - Fireplace and chimney were observed sooted. Both should be professionally cleaned and checked by chimney specialist prior to use. Fireplace #2 Type: Gas Logs Installed - Ventless Prefabricated Firebox / Location: Master Bedroom Verify this gas appliance is approved for a sleeping area before use Isolation Valve - A gas isolation valve was not viewed at or near the inspected unit to fully shut off the gas when servicing unit or to leave unit off for an extended period of time. The inspector recommends properly adding an accessible gas isolation valve for safety. Roger Williamson Page 15 of 29 HomePro Inspection Inc
  • 17. Rural 2007 Built Photo distorted on purpose Electrical The following opinion is based on an inspection of the readily accessible and visible portions of the electrical system. Electrical installation conditions and functional issues requiring correction should be performed by a competent licensed electrical contractor. 1. Electrical Service Underground 200 Amp Service 2. Electrical Distribution Observations: 200 Amps / 120/240 Volts / Breaker Panel Panel Location:At Meter Package heat pump is installed interfering with dedicated service access at exterior main breaker panel. Working Access - This equipment should have unobstructed access of no less than 30" in width and 36" depth as measured out from the inspected item. This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed. 3. Electrical Sub Panel Observations: 200 Amps / 120/240 Volts / Breaker Panel Panel Location:Garage Panel Inspected - The cover was removed from the electrical panel. The interior components were viewed and found to be in satisfactory condition and appear to be properly installed. No repairs are needed to panel or interior components at this time. 4. Electrical Branch Wiring Material: Nonmetallic-Sheathed Cable Observations: Unterminated wiring observed at exterior front yard. Unterminated exposed energized wiring observed at rear exterior patio. Unterminated wiring - Some wires viewed not terminated. Add wire nuts to all unterminated wiring in junction boxes/panel or otherwise properly terminate in junction box with cover as needed. Properly relocate wiring away from attic access as required for safety. Improper wiring - Improper wiring was noted. Have a qualified electrician check and repair as needed for function and safety. Roger Williamson Page 16 of 29 HomePro Inspection Inc
  • 18. Rural 2007 Built Photo distorted on purpose Unterminated wiring observed at exterior front yard. Unterminated exposed energized wiring observed at rear exterior patio. Properly relocate wiring away from attic access as required for safety. 5. Electrical Receptacle Outlets Using a circuit tester, a representative number of grounding type electrical receptacles were randomly checked and correct wiring was indicated. PERIODIC MAINTENANCE NEEDED Missing cover plate -Install switch or receptacle cover plates where missing or damaged to reduce electrical hazard. 6. Electrical GFCI Observations: GFCI Ok - Using a ground fault circuit interrupter (GFCI) tester, receptacles were checked and indicated properly function. Roger Williamson Page 17 of 29 HomePro Inspection Inc
  • 19. Rural 2007 Built Photo distorted on purpose 7. Electrical Lighting Outlets A representative number of installed lighting fixtures were observed and appeared to be generally serviceable within the parameters of their given service life. Not Observed - Street lights at end of drive 8. Smoke Alarms PERIODIC MAINTENANCE NEEDED Check - Check smoke detectors regularly and no less than twice a year when time changes. Refer to installation and care instructions for proper locations and periodic maintenance. Roger Williamson Page 18 of 29 HomePro Inspection Inc
  • 20. Rural 2007 Built Photo distorted on purpose Plumbing The following opinion is based on an inspection of the readily accessible and visible portions of the plumbing system. Plumbing installation conditions and functional issues requiring correction should be performed by a competent licensed plumbing contractor. . 1. Supply Piping Flow: Adequate functional water flow observed The visible portions of water supply piping were found generally serviceable within the parameters of its given service life. No immediate repair concerns were observed. Material: Copper Material: PEX 2. Waste Piping Flow: Functional waste water flow observed The visible portions of waste water piping were found generally serviceable within the parameters of its given service life. No immediate repair concerns were observed. 3. Plumbing Equipment Water pressure acceptable - The water pressure was checked at an outlet located after the pressure reducer, if one was present. The pressure was found to be within the acceptable 40-80 PSI range. See any additional notes regarding functional water flow recorded under plumbing supply piping. Water pressure reducer was observed inside crawl space A water isolation valve was not observed near pressure reducing valve for servicing of pressure reducer. Consider installing isolation valve where missing. A sewage pump was noted. Obtain installation and warranty information. Such pumps should be accessible as they require periodic servicing and have high water alarms. It is outside the scope of the home inspection to remove the the sewage pump lid to verify the unit is functioning properly. Monitor this type of equipment servicing when necessary. The recirculation pump installed at water heater does not appear to be connected electrically Not Working - The inspected item is not operating properly. Properly repair as needed for function and safety. Roger Williamson Page 19 of 29 HomePro Inspection Inc
  • 21. Rural 2007 Built Photo distorted on purpose A sewage pump was noted. The recirculation pump installed at water heater does not appear to be connected electrically 4. Electric Water Heater Typical service life of a water heater is 8-12 years. Location: Garage Size: Covered With Insulation - Water heater is covered with additional insulation over the tank and was not visible. Inspector was unable to determine size or age of water heater. Water heater was observed functional during home inspection Roger Williamson Page 20 of 29 HomePro Inspection Inc
  • 22. Rural 2007 Built Photo distorted on purpose Interior The following opinion is based on an inspection of the readily accessible and visible portions of the interior including Walls, Ceilings, Floors, Steps, Stairways, Balconies, Railings, and Doors. Cosmetic issues are not addressed for these areas but significant physical damage, questionable staining and significant improper function are addressed in this inspection report. Conditions requiring correction for these areas should be performed by a competent qualified contractor. 1. Walls Material: Drywall PERIODIC MAINTENANCE NEEDED Deferred Maintenance - The inspected item suffers from deferred maintenance and is ready for reconditioning. Cracks from expansion or settlement - Noticeable cracking was observed. This is not unusual. Monitor and properly repair as needed. Dining room crown trim and wall appear to have moisture damage. Verify cause of damage, take corrective measures to prevent recurrence and properly repair any affected areas. Stained - The material is stained. Some stains may be very difficult to remove. Before repairing, be sure the source of the stain has been located and cured. Dining room crown moulding Physical Damage - Physical damage was noted and should be properly repaired. Dining room crown trim and wall appear to have moisture damage. Verify cause of damage, take corrective measures to prevent recurrence and properly repair any affected areas. Stained - The material is stained. Some stains may be very difficult to remove. Before repairing, be sure the source of the stain has been located and cured. 2. Ceilings Material: Drywall Cracks Minor - Some cracks were noted that are minor in nature. Small settlement cracks are a common occurrence and can be repaired, providing that the settlement has stopped. Roger Williamson Page 21 of 29 HomePro Inspection Inc
  • 23. Rural 2007 Built Photo distorted on purpose 3. Flooring Material: Carpet Wood Upstairs Incomplete - Typical scope of work for item inspected has not been completed. Additional work/repair should be properly performed to complete area. Right rear room Worn Flooring - The flooring shows wear and may be ready for replacement/refinishing soon. 4. Doors Material: Wood Fiberboard PERIODIC MAINTENANCE NEEDED Minor adjustment needed - The inspected item is functional overall but requires minor routine adjustment for proper operation. 5. Interior Steps No adverse conditions were observed Carpeted steps observed 6. Railings No adverse conditions were observed 7. Windows Materials: Vinyl A representative number of windows were operated and were found generally serviceable within the parameters of their given service life. 8. Window Glazing Insulated glass observed at windows Roger Williamson Page 22 of 29 HomePro Inspection Inc
  • 24. Rural 2007 Built Photo distorted on purpose Kitchen The following opinion is based on an inspection of the readily accessible and visible portions of the kitchen including counters and a representative number of cabinets. The following built in appliances are checked as part of this inspection report if present: Range, Cook top, Oven, Garbage Disposal, Microwave, Trash Compactor, Ventilation Equipment such as a Range Hood. Installed Dishwashers are run through a normal cycle. Appliance inspection does not cover clocks, timers, self cleaning function, calibration or automatic functions. Refrigerators are outside the scope of this inspection and only their presence or absence is noted. Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor. 1. Countertop Countertop Acceptable - The countertop was inspected and found to be generally serviceable within the parameters of its given service life Material: Granite 2. Cabinets Cabinets Acceptable - A representative number of built-in cabinets were inspected and found to be generally serviceable within the parameters of their given service life Material: Wood and Wood Composition Painted 3. Sink and Faucet Observations: PERIODIC MAINTENANCE NEEDED Correct leak at aerator Double Bowl Composition 4. Dishwasher Dishwasher Functional - The dishwasher was run through a normal wash cycle and appeared to be functioning. Additionally, no leaks were observed about the dishwasher during the inspection. Dishwasher service life - Typically dishwashers are designed to last approximately 10 years. PERIODIC MAINTENANCE NEEDED Refer to installation instructions properly securing dishwasher in place Incomplete - Typical scope of work for item inspected has not been completed. Additional work/repair should be properly performed to complete area. 5. Microwave On/Off Tested - Inspected appliance was turned on and off by the normal operating controls. The main function of the appliance appeared to be operating normally. Inspector does not test calibration of appliances or check the function of optional equipment on appliances. Microwave - Permanently Installed Glass tray at bottom of microwave did not move during operation, correct if needed Roger Williamson Page 23 of 29 HomePro Inspection Inc
  • 25. Rural 2007 Built Photo distorted on purpose 6. Cooking Ventilation Above range integral with microwave Ductless 15" deep cabinet above microwave blocks exhaust opening at top front of microwave. Exhaust observed obstructed and proper correction is needed. 15" deep cabinet above microwave blocks exhaust opening at top front of microwave. Exhaust observed obstructed and proper correction is needed. 7. Kitchen Floor Observations: No adverse conditions were observed Material: Wood 8. Laundry Connections Observations: Washer and dryer connections are available but appliances were not present during inspection. Clothes dryer exhausts to an interior area The dryer should exhaust directly to exterior through a metal pipe to reduce moisture inside the home that could be detrimental to building components. 9. Refrigerator A refrigerator was not present Roger Williamson Page 24 of 29 HomePro Inspection Inc
  • 26. Rural 2007 Built Photo distorted on purpose Bath 1 The following opinion is based on an inspection of the readily accessible and visible portions of the bathrooms. Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor. 1. Plumbing Fixtures LOCATION: Master Bath Installed Fixtures Bathing: Hydro massage tub and separate shower Sink: Two basins in vanity Toilet: Water tank type Hydro massage tub - The hydro massage tub was filled and tested. The unit was observed functioning normally. Sink Faucet No Leaks Observed - The inspected faucet was run for longer than one minute. No leaks were viewed at the visible supply lines, faucet or the visible waste drain lines just beneath the sink. Toilet Functional - The toilet was flushed no less than two times. On each operation the toilet refilled and shut off properly. No leaks were noted at toilet. PERIODIC MAINTENANCE NEEDED Shower floor tile are cracked and should be monitored or repaired Tile Cracked - Cracked tile were observed. This can be due to settlement or improper installation. Monitor area budgeting corrections if condition worsens. 2. Ventilation Type Fan on/off tested - The bathroom vent fan was switched on and the sound heard appeared to be appropriate for the fan. It is beyond the scope of the home inspection to determine the effectiveness of the bathroom fan such as to verify air flow quantity or discharge location. 3. Bath Floor Material: No adverse conditions were observed Material: Tile Roger Williamson Page 25 of 29 HomePro Inspection Inc
  • 27. Rural 2007 Built Photo distorted on purpose Bath 2 1. Plumbing Fixtures LOCATION: Hall Bath Installed Fixtures Bathing: Hydro massage tub and separate shower Bathing Area Acceptable - The inspected faucet was run for no less than five minutes checking the tub and shower flow as present. No visible leaks were observed during the inspection and the water containment area appeared serviceable. Sink: Vanity with basin No Leaks Observed - The inspected faucet was run for longer than one minute. No leaks were viewed at the visible supply lines, faucet or the visible waste drain lines just beneath the sink. Toilet: Water tank type Toilet Functional - The toilet was flushed no less than two times. On each operation the toilet refilled and shut off properly. No leaks were noted at toilet. Hydro massage tub - The hydro massage tub was filled and tested. The unit was observed functioning normally. 2. Ventilation Type Type: Fan on/off tested - The bathroom vent fan was switched on and the sound heard appeared to be appropriate for the fan. It is beyond the scope of the home inspection to determine the effectiveness of the bathroom fan such as to verify air flow quantity or discharge location. 3. Bath Floor No adverse conditions were observed Material: Tile Roger Williamson Page 26 of 29 HomePro Inspection Inc
  • 28. Rural 2007 Built Photo distorted on purpose Bath 3 1. Plumbing Fixtures LOCATION: Half Bath Installed Fixtures Sink: Vanity with basin No Leaks Observed - The inspected faucet was run for longer than one minute. No leaks were viewed at the visible supply lines, faucet or the visible waste drain lines just beneath the sink. Toilet: Water tank type Toilet Functional - The toilet was flushed no less than two times. On each operation the toilet refilled and shut off properly. No leaks were noted at toilet. 2. Ventilation Type Type: Fan on/off tested - The bathroom vent fan was switched on and the sound heard appeared to be appropriate for the fan. It is beyond the scope of the home inspection to determine the effectiveness of the bathroom fan such as to verify air flow quantity or discharge location. 3. Bath Floor Material: No adverse conditions were observed Material: Tile Roger Williamson Page 27 of 29 HomePro Inspection Inc
  • 29. Rural 2007 Built Photo distorted on purpose Report Summary Report Summary Outdoor Areas Page 4 Item: 7 Patio All guard rails are less than 36" tall, hand rail at steps is ok at 34" Guardrails where required at elevated walk areas should be at least 36" tall for safety to help reduce falls. The installed guardrail is less than 36” tall. Evaluate your risk exposure correcting as needed for function or safety. Some spindle spacing is too wide Spindle Spacing – Railing spindles should be close together to help prevent falls or entrapment. Spindles should be constructed to reject a 4” sphere or ball being passed through the spindles. Evaluate your risk exposure and properly correct as needed for safety and function. Roofing Page 8 Item: 2 Roof Covering Damaged shingles were observed Apparent moisture damage observed at dining room wall may or may not be related to roof condition. Roofing is ready for periodic maintenance. Have a qualified competent contractor check entire roof system and associated flashings. Repair or replace affected areas as needed. Foundation Page 10 Item: 5 Crawl Space Construction Debris - Construction debris noted in crawl space. Remove Issues debris and wood scraps from crawl space area. Do not forget to check beneath plastic sheeting on ground too if installed. Page 11 Item: 6 Water Control None observed Measures Water Stains - Water stains were noted. Stains are evidence of prior water penetrations. Monitor and repair as needed Standing water was observed in crawl space. Further evaluation is needed to determine source of unwanted water. Take appropriate measures to prevent recurrence and properly correct affected areas as needed. Central Heating and Cooling Page 12 Item: 2 Fuel NOTE TO CLIENT - gas logs viewed but not operated Gas appears off to dwelling - The gas service appears off or out of fuel to the dwelling. The inspector was unable to view any of the gas appliances in operation or check the pipes for gas leaks. Verify appliances functioning normally and no leaks are present prior to settlement. Page 13 Item: 4 AC Function For both units Downstairs unit appeared to be cooling some but not as designed. Upstairs unit was not cooling Properly put both systems back in service correcting as needed for function or safety. System was not cooling properly during inspection. System should be properly serviced correcting as needed for safety and function. Page 13 Item: 5 Duct Ducts need cleaning - Some ducts appear dirty and are ready for cleaning. Ductwork Damaged - The inspector noted damage to the ductwork which requires repair. Check all ductwork and repair as needed. Page 14 Item: 6 Furnace Location Upstairs furnace does not have proper access and was only viewed from a Issue distance by inspector. Consult a competent heating contractor correcting as needed. Irregular construction observed - The inspector recommends further evaluation and proper correction as needed for safety and function. Electrical Roger Williamson Page 28 of 29 HomePro Inspection Inc
  • 30. Rural 2007 Built Photo distorted on purpose Page 17 Item: 4 Electrical Branch Unterminated wiring observed at exterior front yard. Wiring Unterminated exposed energized wiring observed at rear exterior patio. Unterminated wiring - Some wires viewed not terminated. Add wire nuts to all unterminated wiring in junction boxes/panel or otherwise properly terminate in junction box with cover as needed. Properly relocate wiring away from attic access as required for safety. Improper wiring - Improper wiring was noted. Have a qualified electrician check and repair as needed for function and safety. Plumbing Page 20 Item: 3 Plumbing The recirculation pump installed at water heater does not appear to be Equipment connected electrically Not Working - The inspected item is not operating properly. Properly repair as needed for function and safety. Kitchen Page 24 Item: 6 Cooking Ventilation 15" deep cabinet above microwave blocks exhaust opening at top front of microwave. Exhaust observed obstructed and proper correction is needed. Page 24 Item: 8 Laundry Clothes dryer exhausts to an interior area The dryer should exhaust Connections directly to exterior through a metal pipe to reduce moisture inside the home that could be detrimental to building components. Roger Williamson Page 29 of 29 HomePro Inspection Inc