1. JOSHUA VENCENT B. BEDAYOS
Blk16 Lot1 Hauskon Homes, Julugan Tanza, Cavite
Email: joshua.bedayos@yahoo.com
Mobile: 09261144169 / 09192908588
Position Applied: Electrical Technician/Instrument Technician
Work Experience:
JGC PHIL. INC. UNDER CORAL BAY NICKEL CORP. (CBNC, PALAWAN)
(May09, 2012- September 03, 2012)
(August27, 2013-May30, 2014)
(August 14, 2014 –November 24, 2014)
JOB SPECIFICATION/DESCRIPTION:
- Responsible to Lock out Tag out (LOTO) in Control Panel during disconnect or
termination of High/Low Voltage Motor Pump Supply for Safety dismantle or
assemble for the mechanical group of Heavy Duty Motors Pump like ASH Pump,
Denver Pump, Booster Pump and Feed Water Pump.
- Responsible for Cable pulling and Cross Wiring in Control Panel in Motor Control
Center (MCC) High/Low Voltage to supply in Line 1-2 Scrubber area and Punishing
Filter, Reactor Tank and other Motor Pump need to used Variable Speed Drive
(VSD). Inverter in the Conveyor Motor in ORPREP Drum Washer and conveyor to
deliver the coal in the big boiler to ignite and supply steam pressure to the power
plant.
- Responsible to pull out and check diaphragm of transmitter for Tank of the Reactor
Tank, Scrubber 1-3 Tank, H2S line 1-2 tank and Laic Acid Tank, if there is any
damage or need a replacement of new Gasket, Teflon Seal, Teflon Ring for Ring
Frame of diaphragm and assemble Diaphragm. And responsible for calibrate pressure
transmitter, level transmitter and any transmitter by using Druck DPI610 and Hart
2. Application Model 375 and Loop checking/Linear checking by inject able pressure
from transmitter signal to DCS, if there is accurate, and also calibrate the pressure
gage analog in Geho Machine capacity of 1600 KPA, 10000 KPA, 16000 KPA, and
any pressure gage.
- Responsible to pull out accessories of Control Valve, first step call PIC to isolate the
Valve for safety retubing, if there is leak tube accessories the big Pipe that control the
flow of pressurized tank and other pressurized tank.
- Responsible to modify controls such as Motor Controls. Sometimes the PIC request
to add modify Starts Stop Timer delay, current transformer to see the actual current
on board panel and the other is needed to add protective device for safety controls.
- Maintain Miger during black out to check the resistance of the cable, first clamp the
ground then turn right the miger button to see the results if it is not grounded body of
the panel, then check one by one of 3phase L1, L2, L3 cable, and for the motors
winding check the ground and resistance T1, T2, T3 to get condition of the winding,
and to dry the accidental wet windings.
- Responsible for troubleshooting in Geho Motor Pumps, while operating the machine
get emergency shutdown in the (DCS) Distribution Control System was detect an
error from Geho accessories, and the basic troubleshooting to check all proximity
censor connection and clean. Then call to DCS if the error has gone. The Geho
machine will start up again and troubleshooting in other machine.
3. DEADUCK PHIL. INC. (CAVITE )
(Sep. 07, 2012-August 09, 2013)
JOB SPECIFICATION/DESCRIPTION:
- To maintain and repair all machine for good conditioned to operate kind of machine
(HASL) Hot Air Soldering Level, wash and dry loader/unloaded, etching chemical
wash and dry, transporter automation loader/unloaded by controlling of (PLC)
Programmable Logic Control, semiconductor, and also in pneumatic solenoid Valve
control and how to troubleshoot the (PLC).
- field fault analysis – determines if instrument has failed or if it is a process problem;
- field calibration of instrumentation utilizing proper test equipment;
- complete overhaul in shop environment to include component replacements,
alignments and calibration of inverter for motor speed and parameter to
specifications of record;
- repair of signal transmission facility such as tubing, wiring, etc.;
- instrumentation to include pneumatic, electronic and digital equipment;
- fault analysis of hardwire relay logic, motor control circuits, motor power circuits
(120V to 480V 3phase) and common utility / lighting circuits;
- installation of new control circuits, modification of existing instrument/electrical
systems as requested, to include design, load and Implementation of new control logic
- fault analysis and repair of PLC based systems with control logic analysis of 24v.
incoming power service.
- Troubleshoot and repairing the automation machine mechanical and automatic
- electrical controller example of sensor relay and any contactor
JOB DESCRIPTION TRAINING:
OFFICE OF THE CITY ENGINEER (TRECE MARTIRES, CAVITE)
(Jan. 03, 2011-April 29, 2011)
- Maintain to check substation meter daily by using Fluke Tester and Ampere Gage.
- Responsible to maintain streetlight in a good condition and others requested by the
community service according to electrical problem.
4. PERSONAL INFORMATION:
Name : Joshua Vencent B. Bedayos
Age : 24 years old
Date of Birth : November 07, 1990
Place of Birth : Sipalay City, Neg. Occ.
Sex : Male
Height : 5’9”
Weight : 75 kg.
Nationality : Filipino
Civil Status : Married
EDUCATIONAL BACKGROUND:
Primary Education : Cabarrus Catholic College
(1997-2003)
Secondary Education : Tanza National Comprehensive High School
(2003-2007)
Tertiary Education : Cavite State University (BS Electrical Tech)
(2008-2012)
CHARACTER REFERENCE:
Aurillo de Ocampo : Civil Engineer (09178860963)
Leonardo Estero : Professional Electrical Engineer
Arman Mojica : Civil Engineer (09185756802)
Jimmy Cardenas : Electrical Supervisor
I hereby certify that the above information’s are true and correct to the best of my
knowledge and belief.
__________________________________
(Applicant’s Signature)