The Real-World Challenges of Medical Device Cybersecurity- Mitigating Vulnera...
Maximo Oil and Gas 7.6.1 HSE: Organizations & Products overview
1. Maximo Oil and
Gas 7.6.1
Maximo HSE
Manager 7.6.1
Application
Overview
Organizations
clone
2. Organizations clone
Two separate use cases:
1.Loading of ISO14224 failure and
classification data.
2.Oil and Gas/HSE optional settings
2
3. List View actions –
Oil and Gas only
3
Update Asset
Specifications is used
to load ISO14224
Classification data
into Maximo
Update Asset
Specifications is used
to load ISO14224
Classification data
into Maximo
Update Asset Failure
codes is used to load
ISO14224 failure data
into Maximo
Update Asset Failure
codes is used to load
ISO14224 failure data
into Maximo
4. Mapping of Maximo
Oil and Gas to
ISO14224:2006
4
ISO14224 Term Description ISO14224 section ref. Maximo field name Domain Data provided
Failure mechanism
The apparent, observed cause of the
failure B2.2; Table B2
Failure Mechanism Code; Failure
Mechanism Remarks; Failure Mechanism
Subdivision Code: Failure Mechanism
Subdivision Code Remarks Yes
Failure cause Root cause - the initiating event(s) B2.3; Table B3 Failure Reporting - Causes Yes - Update Failure Codes action
Detection method
The method or activity by which a
failure is discovered B2.4; Table B4 Failure Reporting - Detection Method Yes
Maintenance Activity
For corrective maintenance the type of
restoration action performed. For
preventive maintenance the type of
preventive action. B2.5; Table B5 Failure Reporting - Remedies Yes - Update Failure Codes action
Failure Mode
Desired function not obtained, lost or
degraded B2.6; Tables B6-B12
Failure Codes - Problems; Solutions (Oil)
Symptom Yes - Update Failure Codes action
Equipment Class Equipment type classification A2.2.1 Typical Failure Class, Classification Yes - Update Asset Specifications action
Equipment Type Table A5 Typical Classification Yes
Sub Unit/Component Table A6 Typical
Solution/Component Code; Solution
Component Remarks No
Maintainable Item/Part Table A6 Typical
Maintainable Item/Part Code;
Maintainable Item/Part Code Remarks No
Active Repair Time Not currently mapped
Industry Type of main industry Section 8.2 Table 2 Locations (Oil) Industry Yes
Business Category Type of business or processing stream Section 8.2 Table 2 Locations (Oil) Business Category Yes
Installation Type of Facility Section 8.2 Table 2 Locations (Oil) Installation Yes
Plant/Unit Type of Plant/Unit Section 8.2 Table 2 Locations (Oil) Plant/Unit Yes
Section/System Main section/system of the plant Section 8.2 Table 2
Locations (Oil) Section, Locations (Oil)
System Yes
Safety Critical Failures
Systematic and hardware failures
according to IEC 61508 Annex F, Table F1
Safety Failure Category; Hardware Failure
Mode; Common Cause Failure Yes
Operation Category Table 5 Locations (Oil) Operation Category Yes
NormalOperating Mode Table 5 Locations (Oil) Normal Operating Mode Yes
5. Action - Update
Asset
Specifications
5
Load by Organization. If
Update Asset
Specifications? is
unchecked it means
data has already been
loaded for that
Organization
Load by Organization. If
Update Asset
Specifications? is
unchecked it means
data has already been
loaded for that
Organization
On selecting OK user
will be asked to
confirm the action to
load data
On selecting OK user
will be asked to
confirm the action to
load data
6. Action – Update
Failure Codes
6
Load by Organization. If
Update Failure Codes? is
unchecked it means
data has already been
loaded for that
Organization
Load by Organization. If
Update Failure Codes? is
unchecked it means
data has already been
loaded for that
Organization
On selecting OK user
will be asked to
confirm the action to
load data
On selecting OK user
will be asked to
confirm the action to
load data
7. Example of loaded
Failure Codes
7
Failure Codes will be
loaded for all ISO14224
Equipment
Class/Equipment Type
combinations
Failure Codes will be
loaded for all ISO14224
Equipment
Class/Equipment Type
combinations
Cause codes are
common for all
Equipment classes
Cause codes are
common for all
Equipment classes
Problem codes vary
by Equipment Class
Problem codes vary
by Equipment Class
8. Example of loaded
Failure Codes – lower
half
8
Remedy codes are
common for all
Equipment classes
Remedy codes are
common for all
Equipment classes
9. Example of loaded
ISO14224
Classification
9
Classifications will be
loaded for all ISO14224
Equipment
Class/Equipment Type
combinations including
their associated Attributes
Classifications will be
loaded for all ISO14224
Equipment
Class/Equipment Type
combinations including
their associated Attributes
Use with Asset, Item and Locations is
populated by default. Other use with
applications need to be populated by
customers where required
Use with Asset, Item and Locations is
populated by default. Other use with
applications need to be populated by
customers where required
10. Products sub
module
In Oil and Gas/HSE Manager we rename the IT
Infrastructure capability which can be used to
model product numbers for product quality
management use cases. Labelled as Products it
consists of the following three applications:
•Configuration Items
•Relationships
•Collections
These applications are provided unmodified from
the originals.
10