Review on Study of Folded Portable Structure
Prof. Abdul Ghaffar1, Prajakta Lade2, Pranali Thombare3, Rahul Rathod4,
Akshay Bhati5, Anjali Madavi6
1HOD and Assistant Professor, Department of Civil Engineering, JD College of Engineering, Nagpur, India-441501
2,3,4,5,6Final Year Student, Department of Civil Engineering, JD College of Engineering, Nagpur, India-441501
---------------------------------------------------------------------------***---------------------------------------------------------------------------
Abstract - Folded portable structure is a structure which is transportable, we can erect it from one place mount it on truck
trailer and assembled to desired location. This type of structure is folded having provision of a transformation and increase
their space from two sides with a desired ratio and also capable to reduce in their original area for transportation. Folded
portable structure is new concept based on prefabricated structure have a vast area of study and a lot of advantage over
traditional construction system. This type of architecture is easily achieving a nametag of sustainable structure but required
high technical evolution to obtain proper design which is durable, repairable and creates progressively efficient use of energy
and other resources. A review paper is introduced here to study the design principle and mechanism of folded portable
structure with analyze numerous Folded portable structure that have been built, reviewing their achievements and
deficiencies whereas reviewing their technical evolution and study to examine it on context of design principle of
sustainability .
Key Words: - Folded Portable Structure, Transformable, Prefabricated, Design Principal, and Sustainability.
1. INTRODUCTION
Prefabricated folded portable structure components are manufactured in factory and assembled on site so it significantly
reduced the time of construction, construction waste, and improved air quality; achieve site safety, sustainability and
better quality than conventional construction method. Exist prefabricated folded portable structure are widely used for
dwelling as a permanent and temporary occupation workforces involved in framing, mining, construction, military, re-
construction and residential housing unit for remote, rural and slum area. It is a best solution for emergency housing
solution in disaster suffered area for the provision of medical and dwelling services to the victims. Folded portable
structure designed from an assembly, that can be transported by road and airway to the site and erected to the site with
minimum time with suitable mechanism and make transformation to their area by increasing or reducing it with fold and
unfold. This review paper is presenting here to study the various folded portable structure that exist in the present era and
analyze them in the context of sustainability, mechanism used to fold and unfold the structure and the design principle of
the structure. Design principle includes structural1, technical2 and functional3 criteria which denote stability1, rigidity1,
lightness of system2, modulation and assembling between elements2, transformability3 and transportability3. . To study
folded portable structure various components are important to study and understand which are divided into three
components like moment component, load bearing structure and planar surface component. All three components are
interdependent on each other and their synchronization is important to maintain its functionality and obtain folded
portable structure. Here the study is focused about understanding different component, their co-ordination with each
other, assembly between elements, achieved functionality in the design principle. Folded portable structure various type
of model comparison is done on context of sustainability to identify eco-friendly design by considering principle of
sustainability.
2. Methodology
The aim of the review is to clear the concept of folded portable structure, to improve understanding about various
component of folded portable structure and their interdependency on each other, analyze various existing design of folded
portable structure to find out their functionality, mechanism and design strategy and review is this structure is able to
adapt the principle of sustainability or not.
The diagram present below represent the procedure to study folded portable structure.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1214
Fig 1:-procedure followed to study folded portable structure
2.1 INTRODUCTION OF FOLDED PORTABLE STRUCTURE.
Folded portable structure are prefabricated structure constructed with different type of material including steel ,
aluminum , plastic which are able to construct a durable structure and achieve design stability, serviceability sustainability
with comfort of living being. ‘”Folded” describe various folded connection between various component like floor, Roof,
planner Connection which easily fold and unfold using movement connection and mechanism. The start force that
generates the movement can be natural (human handed) or mechanical including hydraulic or rack and pinion mechanism.
“Portable” includes structure which can transport from one place to another.
According to literature review of various authors In 2007 Robert Kronenburg, says that Folded “includes changing design
buildings, space, form and shape by physically altering its structure, interior or skin. It is an architecture that opens, closes,
expands and contracts”. And portable “includes buildings that move from one place to another in order to better play its
role: it is an architecture that rolls, floats or flies” (Kronenburg, 2007). Maziar Asefi, who publish in 2010 his research
where he “describes a distinct class of structures consisting of rigid, or transformable elements, connected by moveable
joints that can change their geometry reversibly and repeatedly and have the innate characteristic of controlled
reconfiguration” (Asefi, 2010).
2.2 DESIGN PRINCIPLE OF FOLDED PORTABLE STRUCTURE:-
Study of various component of folded portable structure is divided into three component like movement mechanisms, load
bearing structure and planar surface components. In terms of functionality of design, proper synchronization of all three
component have to be take into consideration, to obtain proper working of the proposed design of folded portable
structure.
Fig 2:-Component Divided According to Design Principle of folded portable structure
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1215
2.2.1 Movement Mechanism
Analyzing the practical, functional and stability criteria and designing a movable joint, for a dynamic connection, is an
extensive and technical work. Industry catalogues have been providing mostly documentation about mechanisms
connections of folded structure which having authorities’ approval. In professional design of folded portable structure
having understanding related to connection elements and their relation with type of movement desired to make the
correct choice is important to avoid malfunction of technical design.
To understand movement connections and their mechanism various factors are important to studied.
Fig 3:-Principle of folded portable structure
2.2.1.1 Movable Connection
In Folded structure, so as to allow the movement to happen, static components are associated by movable joints, changing
over them into folded structure. Movement joints are not just an association between two components, it should likewise
exchange loads permit relative motion in some directions while constrain in others. The types and direction of movement
are connected with the degrees of freedom allowed by each joint, they derivate from the combination of the axis of the
movement and the typology of movement. The first thing to observe when choosing a connection is it is self-load bearing
or if it makes part of the whole structure.. Both hinged and bearing have a extend options in commercial catalogues and it’s
easy to find the load specification on the technical documentations.
Revolution Joints
Revolution joints are connections of hinged elements that turn around an axis have a single degree of freedom of rotation.
Immense variety of hinges are available in industry catalogues and for developing specifications, some basic knowledge is
needed. Besides if the hinge fits the overall design, it’s important to know the axis of rotation, the load that the hinge must
stand and it relation with size and material and the angle of movement. These first specifications are probably the most
important; the load can determine the number and size of joints needed, and the axis the necessity of angle and torque
control.
Fig 4: - Revolution Joints
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1216
Bearings
Bearings containing fluids to separate the surfaces of contact are used to reduce friction between connections.
Fig 5:- Sliding Bearing
Fig 6: - Roller Bearing
2.2.1.2 Control Mechanism
Control mechanism is responsible to perform motion in a stable body and give it dynamic movement. Connection give in
between folded portable structure control the dynamic movement of structure by adjusting its force and speed and
changing direction of movements Control means include sliders, gears, pneumatics, actuators, hinges and linkages.
Fig 7:-Examples of Control Means Types
Types of
bearing
1.sliding bearing 2.roller bearing 3. Common bear-
ings
Applied use in
folded
portable
structure
Support high loads
with high speed
revolution and are
impact-resistant,
noise-absorbent but
with higher degree
of maintenance.
Intermediary ele-
ments to transfer
forces, requiring
lower lubrication and
maintenance, but they
are susceptible to
impact damage.
translation
movements with
the basic principle
of wheel-rail
systems
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1217
In 2012 Author (Schumacher) divided control mechanisms of this type of dynamic structure in four main types of simple
machines.
1. Rope and rod- allow rigid objects to be pushed or pulled using a rope and bar, applying the same amount of force in the
same direction but at a different point.
2. Rope and pulley- direction of the force can be changed
3. Lever- allow to change the magnitude of the force
4. Inclined plane- change magnitude of force.
Fig 8:-Examples of Control Mechanisms Machines
2.2.1.3 Control Mechanism
To correlate the relation between mechanism and motion with type, direction and force of movement the present chart are
followed.
Fig 9:-To Change Direction of Movement
Fig 10:-To Change Type of Movement
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1218
Fig 11:-To Change Output Force and Speed
2.2.2 Load Bearing Structure’s
Unlike static structures, the requirements of portable dynamic structures differ because movements are necessary and are
part of its conversions, and issues such as stiffness, stability and resistance must not be simply addressed, but controlled.
Stability is essential both in its “closed” and in its “open” positions (Schumacher, 2010).But to achieve transformation
process folded kinetic structure need support machinery during movement. This generates high operating costs and
compromises more easily a long-term operation of mechanisms and connections.
Focused on transportation methods of dynamic folded structure; it restricts the dimensions of the folded building and the
overall weight. If the buildings include auxiliary lifting points and vehicles are needed to promote displacement, the
structure has to resist the stress generated by the movement. Considering the foundations is also an objective, it’s
important to have the perfect level in the structure for the proper occupancy and the correct function of mechanisms. The
mobile architecture can be placed in different locations with different contexts, and it is important that the foundation is
flexible enough to adapt without improvisations.
Fig 12:- An example of corner lifting points in containers
Folded transformable structure, need to be capable to bear the load in three different moments:
1. The close position- usually when transports also occurs and it has to be stable during lifting and displacement;
2. The opening position- when transformation is taking place and structure is not stable;
3. The open position- where the transformation has been completed and components are locked in place and the stable
structure is once again reached.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1219
Fig13: - Deployable positions of transformation of folded portable structure
2.2.2.1 Dynamically Self-erecting Structures
The mechanism to achieve Dynamically Self-erecting Structures is the use of linked, folding supports in a cross-cross “X”
pattern, known as a pantograph (or scissor mechanism) OR lever arm based structure. the motion is achieved by the
application of pressure one side to deployed it to other side , elongating the crossing pattern, and propelling the structure
in the deployable direction is depend on design of structure. The direction and form of the deployed structure can be
defined by the angle and position of linkage between the bars. The most difficult point is to determine how much of
opening each scissor will realize, how to achieve the precision needed at the end of deployment for the structure be perfect
connected and stable. the movement of the scissor action can be hydraulic, pneumatic or mechanical (via a lead screw or
rack and pinion system) and with the right control, specifications and leveling in site these applications can, not only put
the structure in motion, but also control the opening of each mechanism.
Fig 14:- Deployable Folded Portable Structure manufactured by tenfold engineering based on scissor mechanism.
2.2.2.2 Expandable Folded Portable Structure
Expandable architecture refers to an architecture transformation which fundamentally affects the whole building form and
where the components parts are pre-hinged and continuous, and remains so through transformation (Zuk and Clark,
1979). This can be also the characteristics of kinetic components and self-erecting structure, but the major difference is
that in expandable architecture the basic elements are connected at all times and depend of each other to achieve
transformation. Be sides these, this architecture may be referred as “expandable” and takes advantages of the combination
of rigid and deformable elements for construction.
Pre-hinged construction systems, usually with a kit form of auxiliary parts. Folding mechanism is commonly used in this
system. A notable advantage is the little depth or thickness in transportation, being able to transport a larger quantity in a
same vehicle. As the building is unfolded, the structure is also unfolded and within the envelope, it’s unstable and there is
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1220
the need of auxiliary equipment. Once the unfolding process is completed, and the fixations and locks realized, the rigid
elements have a load bearing capacity and are stable
Fig 15:- Expandable Folded Portable Structure
2.2.2.3 Piers and Foundation
The fixations and foundations of folded portable structure are probably the crucial part of a structure project. The correct
leveling of the building is what can determine the correct function of connection mechanisms and mobile components for
being transportable; a project needs to foresee the different location sites and possibilities that the building may
encounter in throughout its life. There are multiple options when choosing piers and foundations, and all depends on the
project and soil conditions of the terrain, but a few basic recommendations can be made.
Base Pads
Base pads are used as a base plate to eliminate deflection and preventing the piers and foot of sinking into the ground. The
size of a pad is directly related with the item it supports, material and variation of load capacities. In the commercial cata-
logue is possible to encounter pads with different materials that are light-weighed and low dimensioned, which favors the
relocation and reuse(Figure 65). For piers are used plywood, metallic and ABS pads; for footing are used metallic and
plastic; nevertheless, the more advertised and commercialized is the plastic and ABS bases, reassuring the lightweight
properties and the capability of absorbing vibrations.
Piers and Footing
The principal differences of piers and footing are the load, the height and time of use locations- for faster relocating
buildings, the footing system are easier to use . But booth should use the screw jacks mechanical devices to lift and leveling
the buildings. The “jack” employs screw thread or hydraulic cylinder to lift heavy loads and apply great linear forces.
Normally, screw jacks are simple mechanisms that need to be manually operated until reaching the grading desired, they
can reach high load capacity (1.5 – 3tons) and, when threaded, high height (24 inches) . Although, they are not recom-
mended for buildings that need complex grading adjustments because of the difficulties of an accurately assemble and risk
situations for workers. They have great use for foot of buildings and kinetic components, in this last case, they can be an
auxiliary support for the frame structure and help to lock the components in place.
Fig 16:-Base Pads Fig 17:- Piers
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1221
2.2.3 Planar Surface Components
Surface elements of folded portable structure representing the active layer and inquiring the specifications necessity of
covering materials, sealing joints and installation system in a structure and their relationship to the whole as: site,
structure, skin, services, space plan, and stuff. structure is the load bearing elements, foundation and skeleton; skin is the
exterior surface, such as siding and windows; services are the nervous systems of a building, such as its heating plant,
wiring, and plumbing; space plan includes walls, flooring, and ceilings; and stuff includes lamps, chairs, appliances, bulletin
boards, and paintings (brand, 1994). A good strategy to achieve this is to reduce the assembly parts, by using better
specific materials that fulfill more performance requirements. Reducing assembly time and cost depending on methods
and processes with a faster implementation and a less potential to failures
Material
Covering materials in this type of building should not only perform properly as enclosure, but they should also resist
repeated movement and environmental changes before, during and after transformation (Asefi, 2010). Also, the skin
contributes to the self-weight of the construction and in the dimensions of movable elements (Schumacher, 2010) and
light-weight materials should be considered at all times. Industry offers a variety options with different resistance and
rigidity characteristics and the shape alterations of the cover components need to be think of since the beginning of the
project. Is the skin stable and moves with the structure, or is it flexible and cover the structure as it moves? Many factors of
materials characteristics like Translucency, Fire,. Water-proof mechanical resistance, cleaning, insulation is important,
recycling.
2.3 INTRODUCTION OF SUSTAINABLE STRUCTURE AND DESIGN PRINCIPAL OF SUSTAINABILITY.
Introduction of Sustainable Structure:-
Sustainable structure is the practice of creating structures using resources that are environmentally responsible and
energy-efficient. It encompasses factors such as internal and external design, construction, operation, maintenance,
renovation, and deconstruction. The aim of sustainable building design is to reduce the overall impact of the built
environment on human health and the natural environment (Anonymous, 2014a).This design practice emphasizes
efficiency of heating and cooling systems; alternative energy sources such as solar hot water, appropriate building siting,
reused or recycled building materials; on-site power generation - solar technology, ground source heat pumps, wind
power; rainwater harvesting for gardening, washing and aquifer recharge; and on-site waste management such as green
roofs that filter and control storm water runoff (Yan and Stallions 2006). Sustainable building is the practice of creating
structures using resources that are environmentally responsible and energy-efficient. It encompasses factors such as
internal and external design, construction, operation, maintenance, renovation, and deconstruction. The aim of sustainable
building design is to reduce the overall impact of the built environment on human health and the natural environment
(Anonymous, 2014a).
Fig 18:- Main goals for sustainable structure design (Anonymous, 2014a)
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1222
Design Principal of Sustainability
2.4 EXISTING FOLDED PORTABLE STRUCTURE ANALYTICAL STUDY
Fig 19:-Ten Fold Structure
1. Optimization of resources (natural and artificial): Structure that use natural
durable, reclaimed and re-usable materials and resources can be designed.
2. Reduction of energy consumption: Designing bioclimatic buildings, having energy
efficient construction solutions that use natural energy sources and local materials.
Reducing transportation of materials.
3. Utilization of alternative energy sources: Buildings using wind, solar and
geothermal energy as passive-active integrated systems can be designed.
4. Reduction of waste and emissions: To reduce and manage the pollution and waste,
it can be used waste products, putrescible and non-polluting materials.
5. Improving people’s health and wellbeing: Fulfilling people’s social life and
relations and enhancing their life quality, using of healthy materials, providing natural
ventilation.
6.Reduction of building costs and maintenance: To reduce price and maintenance
buildings having extended life cycles and technological solutions can be designed, by
using reclaimed and re-used materials
System Pantograph hybrid
Structure Dynamically self-erecting
Architect David Martyn
Company Ten Fold Engineering
Year Patent 2012
Location United Kingdom
Use Stage
1. TEN FOLD STRUCTURE
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1223
Fig 20:- Assembly of Ten Fold Structure
Fig 21:- Transportation System of Ten Fold Structure
TEN FOLD STRUCTURECOMPONENTS
Movement Mechanisms
 Deployment in 8 minute with 10 persons
 pin-jointed linkage of lever arm(Scissor) with walls that perform specific useful moment repeatedly,
precisely and reversibly in such a way that they can fold up, including folded roof and floor with each
element counterbalancing the other so that very little power is needed to drive then
Load Bearing Structure
 It uses a double single scissor {Lever Arm} All the linkage can be driven by almost any one of the
individual bars of the linkage by using hydraulic or rack and pinion mechanism. This gives them extreme
versatility and flexibility in all application are obviates the need for complex locking and feedback system.
Planar Surface Components
 75-120mm free finished composite panels
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1224
Transformable Design Strategies
Design
Expansion and
Flexibility
Expanded counterbalance mechanism from two side due to
hydraulic mechanism and lever arm reliably
Compactability and
Transportability
64m2 of flexible, ready-to-use space delivered in 8 minutes from a
standard truck The Module expands upwards and outwards
simultaneously providing 32m2 of additional
floor space
Structural Stability and Deformability Stable at all times
Architectural
Obstruction
The interior is used for storage of movable components Moveable
internal walls and
Exchangeable pods t
Operating System Automatic using hydraulic mechanism.
Construction and Operations
Reliability and Safety The units are easily customized and
readily adaptable to user and site
Specifics. All units and their related Pods are modular, interconnect
able
and interchangeable and provide
high quality, flexible space and
facilities for living and working to
suit user and site specifics in almost
any environment or working sector
Manufacture and
Shipment
industrial constructions under prefabrication premises
Life-Expectancy TEN FOLD units are robust and
resilient, long-life, well-insulated
buildings designed to be moved and moved again but with the
designed performance characteristics expected of a solid building.
The
units can be built to international
standards and designed to comply
with the broadest ranges of local
construction codes
Capital Cost 129000 dollar
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1225
2.5 STUDIE ON FOLDED PORTABLE STRUCTURE BY DESIGN PRINCIPAL OF SUSTAINABILITY
3. CONCLUSIONS
Folded Portable structures are a vast field of study, and each of the subjects cover in this research can be explored to study
the basic concept of this type of type of structure and to study about sustainability principle and state that prefabricated
structure has more capability to attain sustainability as compared conventional structure.
Here the component of folded portable structure with their mechanical and movable connections properties and the
relation with the structure and the movement realized can be studied. And with that study, analysis of existing ten folds
structure are done on various parameters with the checking of it sustainability. This research aims to evaluate the
technical means of a structure transformation of folded portable structure and design decisions required for it success. In
order to better explain transformation from this technical perspective.
4. References
1) Kronenburg, R. 2003. Portable Architecture, Burlington: Elsevier.
2) Kronenburg, Robert. Flexible. Architecture that Responds to Change .London: Art Blume, 2007. Print.
3) Kronenburg, R.: 1997, Transportable Environments: Papers from the International Conference on Portable
Architecture, E & FN Spoon, and London.
4) Zuk, William; Clark, Roger H. Kinetic Architecture. United States of America and Canada: Van Nostrand Reinhold
Company, 1970. Print.
5) Barcelona, España, Transformable and transportable architecture: analysis of buildings components and
Strategies for project design September, 2013.
6) Esra Lakot Alemdağ1, Özlem AYDIN1,A study of Shipping Containers as a Living Space in Context of Sustainability,
28.01.2015, Turkey.
1. Optimization of resources (natural and artificial):
Tenfold Structure use durable, reclaimed and re-usable materials and resources and designed
as a prefabricated structure.
2. Reduction of energy consumption:
Tenfold is designed as a prefabricated structure constructed in factory so reduce and
minimized construction waste and reduce transportation cost and save land as foundation are
not stuck to ground.
4. Reduction of waste and emissions:
Conventional building contributes to CO2 emission prefabricated structure with composite
material panel reduce Contribution to emission and help to maintain ecological parameter
balance
5. Improving people’s health and wellbeing:
Tenfold structure provide comfort, luxurious life to the people by designing are able to done
with peoples requirement and have ability to maintain people healthy
6.Reduction of building costs and maintenance:
Cost of structure is high with low maintenance cost.

More Related Content

Similar to IRJET- Review on Study of Folded Portable Structure

Design and analysis of fixture for a stone crusher body
Design and analysis of fixture for a stone crusher bodyDesign and analysis of fixture for a stone crusher body
Design and analysis of fixture for a stone crusher body
eSAT Journals
 

Similar to IRJET- Review on Study of Folded Portable Structure (20)

IRJET- Feasibility Study of Hexagonal Building Projects
IRJET- Feasibility Study of Hexagonal Building ProjectsIRJET- Feasibility Study of Hexagonal Building Projects
IRJET- Feasibility Study of Hexagonal Building Projects
 
Review Paper on Comparative Analysis of Circular and Rectangular Building Str...
Review Paper on Comparative Analysis of Circular and Rectangular Building Str...Review Paper on Comparative Analysis of Circular and Rectangular Building Str...
Review Paper on Comparative Analysis of Circular and Rectangular Building Str...
 
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABSIRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
IRJET- Pushover Analysis on Reinforced Concrete Building using ETABS
 
IRJET- U-Boot Technology
IRJET-  	  U-Boot TechnologyIRJET-  	  U-Boot Technology
IRJET- U-Boot Technology
 
IRJET-Analysis of a Multistoried Commercial Cum Residential Building using ETABS
IRJET-Analysis of a Multistoried Commercial Cum Residential Building using ETABSIRJET-Analysis of a Multistoried Commercial Cum Residential Building using ETABS
IRJET-Analysis of a Multistoried Commercial Cum Residential Building using ETABS
 
A Review on Design and Analysis of Multi-Storey Building with a Single Column
A Review on Design and Analysis of Multi-Storey Building with a Single ColumnA Review on Design and Analysis of Multi-Storey Building with a Single Column
A Review on Design and Analysis of Multi-Storey Building with a Single Column
 
Investigation of practical life line rcc multistoried building structure & it...
Investigation of practical life line rcc multistoried building structure & it...Investigation of practical life line rcc multistoried building structure & it...
Investigation of practical life line rcc multistoried building structure & it...
 
IRJET- Retrofitting of Reinforced Concrete Structures
IRJET-  	  Retrofitting of Reinforced Concrete StructuresIRJET-  	  Retrofitting of Reinforced Concrete Structures
IRJET- Retrofitting of Reinforced Concrete Structures
 
Kinetic Buildings in Climate-Responsive Architecture
Kinetic Buildings in Climate-Responsive ArchitectureKinetic Buildings in Climate-Responsive Architecture
Kinetic Buildings in Climate-Responsive Architecture
 
IRJET- Comparative Study of Flat Slab Structure and Conventional Slab Structu...
IRJET- Comparative Study of Flat Slab Structure and Conventional Slab Structu...IRJET- Comparative Study of Flat Slab Structure and Conventional Slab Structu...
IRJET- Comparative Study of Flat Slab Structure and Conventional Slab Structu...
 
IRJET- A Review of Behaviour of Building under Earthquake with or without...
IRJET-  	  A Review of Behaviour of Building under Earthquake with or without...IRJET-  	  A Review of Behaviour of Building under Earthquake with or without...
IRJET- A Review of Behaviour of Building under Earthquake with or without...
 
IRJET - Design and Analysis of Clubhouse
IRJET - Design and Analysis of ClubhouseIRJET - Design and Analysis of Clubhouse
IRJET - Design and Analysis of Clubhouse
 
COMPARATIVE SEISMIC ANALYSIS OF A MULTI-STOREY RCC STRUCTURE WITH & WITHOUT F...
COMPARATIVE SEISMIC ANALYSIS OF A MULTI-STOREY RCC STRUCTURE WITH & WITHOUT F...COMPARATIVE SEISMIC ANALYSIS OF A MULTI-STOREY RCC STRUCTURE WITH & WITHOUT F...
COMPARATIVE SEISMIC ANALYSIS OF A MULTI-STOREY RCC STRUCTURE WITH & WITHOUT F...
 
IRJET- Analysis, Design and Estimation of Multi- Storied Residential Buil...
IRJET-  	  Analysis, Design and Estimation of Multi- Storied Residential Buil...IRJET-  	  Analysis, Design and Estimation of Multi- Storied Residential Buil...
IRJET- Analysis, Design and Estimation of Multi- Storied Residential Buil...
 
Design and analysis of fixture for a stone crusher body
Design and analysis of fixture for a stone crusher bodyDesign and analysis of fixture for a stone crusher body
Design and analysis of fixture for a stone crusher body
 
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
 
Seismic Base Isolation of RC Frame Structures with and Without Infill
Seismic Base Isolation of RC Frame Structures with and Without InfillSeismic Base Isolation of RC Frame Structures with and Without Infill
Seismic Base Isolation of RC Frame Structures with and Without Infill
 
IRJET- A Review: Design, Analysis & Optimization of Drag Chain Conveyer
IRJET- A Review: Design, Analysis & Optimization of Drag Chain ConveyerIRJET- A Review: Design, Analysis & Optimization of Drag Chain Conveyer
IRJET- A Review: Design, Analysis & Optimization of Drag Chain Conveyer
 
STUDY ON THE EFFECT OF BEHAVIOUR OF STRUCTURES ON SLOPED GROUND SUBJECTED TO ...
STUDY ON THE EFFECT OF BEHAVIOUR OF STRUCTURES ON SLOPED GROUND SUBJECTED TO ...STUDY ON THE EFFECT OF BEHAVIOUR OF STRUCTURES ON SLOPED GROUND SUBJECTED TO ...
STUDY ON THE EFFECT OF BEHAVIOUR OF STRUCTURES ON SLOPED GROUND SUBJECTED TO ...
 
IRJET- A Critical Review on Bellow Part Removal Fixture
IRJET-  	  A Critical Review on Bellow Part Removal FixtureIRJET-  	  A Critical Review on Bellow Part Removal Fixture
IRJET- A Critical Review on Bellow Part Removal Fixture
 

More from IRJET Journal

More from IRJET Journal (20)

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web application
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
 

Recently uploaded

DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
MayuraD1
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
 
Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
pritamlangde
 

Recently uploaded (20)

DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
 
Computer Graphics Introduction To Curves
Computer Graphics Introduction To CurvesComputer Graphics Introduction To Curves
Computer Graphics Introduction To Curves
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
Electromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptxElectromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptx
 
457503602-5-Gas-Well-Testing-and-Analysis-pptx.pptx
457503602-5-Gas-Well-Testing-and-Analysis-pptx.pptx457503602-5-Gas-Well-Testing-and-Analysis-pptx.pptx
457503602-5-Gas-Well-Testing-and-Analysis-pptx.pptx
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
Linux Systems Programming: Inter Process Communication (IPC) using Pipes
Linux Systems Programming: Inter Process Communication (IPC) using PipesLinux Systems Programming: Inter Process Communication (IPC) using Pipes
Linux Systems Programming: Inter Process Communication (IPC) using Pipes
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
 
Signal Processing and Linear System Analysis
Signal Processing and Linear System AnalysisSignal Processing and Linear System Analysis
Signal Processing and Linear System Analysis
 
Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
 
BhubaneswarđŸŒčCall Girls Bhubaneswar ❀Komal 9777949614 💟 Full Trusted CALL GIRL...
BhubaneswarđŸŒčCall Girls Bhubaneswar ❀Komal 9777949614 💟 Full Trusted CALL GIRL...BhubaneswarđŸŒčCall Girls Bhubaneswar ❀Komal 9777949614 💟 Full Trusted CALL GIRL...
BhubaneswarđŸŒčCall Girls Bhubaneswar ❀Komal 9777949614 💟 Full Trusted CALL GIRL...
 
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best ServiceTamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...Basic Electronics for diploma students as per technical education Kerala Syll...
Basic Electronics for diploma students as per technical education Kerala Syll...
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
fitting shop and tools used in fitting shop .ppt
fitting shop and tools used in fitting shop .pptfitting shop and tools used in fitting shop .ppt
fitting shop and tools used in fitting shop .ppt
 

IRJET- Review on Study of Folded Portable Structure

  • 1. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1213 Review on Study of Folded Portable Structure Prof. Abdul Ghaffar1, Prajakta Lade2, Pranali Thombare3, Rahul Rathod4, Akshay Bhati5, Anjali Madavi6 1HOD and Assistant Professor, Department of Civil Engineering, JD College of Engineering, Nagpur, India-441501 2,3,4,5,6Final Year Student, Department of Civil Engineering, JD College of Engineering, Nagpur, India-441501 ---------------------------------------------------------------------------***--------------------------------------------------------------------------- Abstract - Folded portable structure is a structure which is transportable, we can erect it from one place mount it on truck trailer and assembled to desired location. This type of structure is folded having provision of a transformation and increase their space from two sides with a desired ratio and also capable to reduce in their original area for transportation. Folded portable structure is new concept based on prefabricated structure have a vast area of study and a lot of advantage over traditional construction system. This type of architecture is easily achieving a nametag of sustainable structure but required high technical evolution to obtain proper design which is durable, repairable and creates progressively efficient use of energy and other resources. A review paper is introduced here to study the design principle and mechanism of folded portable structure with analyze numerous Folded portable structure that have been built, reviewing their achievements and deficiencies whereas reviewing their technical evolution and study to examine it on context of design principle of sustainability . Key Words: - Folded Portable Structure, Transformable, Prefabricated, Design Principal, and Sustainability. 1. INTRODUCTION Prefabricated folded portable structure components are manufactured in factory and assembled on site so it significantly reduced the time of construction, construction waste, and improved air quality; achieve site safety, sustainability and better quality than conventional construction method. Exist prefabricated folded portable structure are widely used for dwelling as a permanent and temporary occupation workforces involved in framing, mining, construction, military, re- construction and residential housing unit for remote, rural and slum area. It is a best solution for emergency housing solution in disaster suffered area for the provision of medical and dwelling services to the victims. Folded portable structure designed from an assembly, that can be transported by road and airway to the site and erected to the site with minimum time with suitable mechanism and make transformation to their area by increasing or reducing it with fold and unfold. This review paper is presenting here to study the various folded portable structure that exist in the present era and analyze them in the context of sustainability, mechanism used to fold and unfold the structure and the design principle of the structure. Design principle includes structural1, technical2 and functional3 criteria which denote stability1, rigidity1, lightness of system2, modulation and assembling between elements2, transformability3 and transportability3. . To study folded portable structure various components are important to study and understand which are divided into three components like moment component, load bearing structure and planar surface component. All three components are interdependent on each other and their synchronization is important to maintain its functionality and obtain folded portable structure. Here the study is focused about understanding different component, their co-ordination with each other, assembly between elements, achieved functionality in the design principle. Folded portable structure various type of model comparison is done on context of sustainability to identify eco-friendly design by considering principle of sustainability. 2. Methodology The aim of the review is to clear the concept of folded portable structure, to improve understanding about various component of folded portable structure and their interdependency on each other, analyze various existing design of folded portable structure to find out their functionality, mechanism and design strategy and review is this structure is able to adapt the principle of sustainability or not. The diagram present below represent the procedure to study folded portable structure.
  • 2. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1214 Fig 1:-procedure followed to study folded portable structure 2.1 INTRODUCTION OF FOLDED PORTABLE STRUCTURE. Folded portable structure are prefabricated structure constructed with different type of material including steel , aluminum , plastic which are able to construct a durable structure and achieve design stability, serviceability sustainability with comfort of living being. ‘”Folded” describe various folded connection between various component like floor, Roof, planner Connection which easily fold and unfold using movement connection and mechanism. The start force that generates the movement can be natural (human handed) or mechanical including hydraulic or rack and pinion mechanism. “Portable” includes structure which can transport from one place to another. According to literature review of various authors In 2007 Robert Kronenburg, says that Folded “includes changing design buildings, space, form and shape by physically altering its structure, interior or skin. It is an architecture that opens, closes, expands and contracts”. And portable “includes buildings that move from one place to another in order to better play its role: it is an architecture that rolls, floats or flies” (Kronenburg, 2007). Maziar Asefi, who publish in 2010 his research where he “describes a distinct class of structures consisting of rigid, or transformable elements, connected by moveable joints that can change their geometry reversibly and repeatedly and have the innate characteristic of controlled reconfiguration” (Asefi, 2010). 2.2 DESIGN PRINCIPLE OF FOLDED PORTABLE STRUCTURE:- Study of various component of folded portable structure is divided into three component like movement mechanisms, load bearing structure and planar surface components. In terms of functionality of design, proper synchronization of all three component have to be take into consideration, to obtain proper working of the proposed design of folded portable structure. Fig 2:-Component Divided According to Design Principle of folded portable structure
  • 3. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1215 2.2.1 Movement Mechanism Analyzing the practical, functional and stability criteria and designing a movable joint, for a dynamic connection, is an extensive and technical work. Industry catalogues have been providing mostly documentation about mechanisms connections of folded structure which having authorities’ approval. In professional design of folded portable structure having understanding related to connection elements and their relation with type of movement desired to make the correct choice is important to avoid malfunction of technical design. To understand movement connections and their mechanism various factors are important to studied. Fig 3:-Principle of folded portable structure 2.2.1.1 Movable Connection In Folded structure, so as to allow the movement to happen, static components are associated by movable joints, changing over them into folded structure. Movement joints are not just an association between two components, it should likewise exchange loads permit relative motion in some directions while constrain in others. The types and direction of movement are connected with the degrees of freedom allowed by each joint, they derivate from the combination of the axis of the movement and the typology of movement. The first thing to observe when choosing a connection is it is self-load bearing or if it makes part of the whole structure.. Both hinged and bearing have a extend options in commercial catalogues and it’s easy to find the load specification on the technical documentations. Revolution Joints Revolution joints are connections of hinged elements that turn around an axis have a single degree of freedom of rotation. Immense variety of hinges are available in industry catalogues and for developing specifications, some basic knowledge is needed. Besides if the hinge fits the overall design, it’s important to know the axis of rotation, the load that the hinge must stand and it relation with size and material and the angle of movement. These first specifications are probably the most important; the load can determine the number and size of joints needed, and the axis the necessity of angle and torque control. Fig 4: - Revolution Joints
  • 4. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1216 Bearings Bearings containing fluids to separate the surfaces of contact are used to reduce friction between connections. Fig 5:- Sliding Bearing Fig 6: - Roller Bearing 2.2.1.2 Control Mechanism Control mechanism is responsible to perform motion in a stable body and give it dynamic movement. Connection give in between folded portable structure control the dynamic movement of structure by adjusting its force and speed and changing direction of movements Control means include sliders, gears, pneumatics, actuators, hinges and linkages. Fig 7:-Examples of Control Means Types Types of bearing 1.sliding bearing 2.roller bearing 3. Common bear- ings Applied use in folded portable structure Support high loads with high speed revolution and are impact-resistant, noise-absorbent but with higher degree of maintenance. Intermediary ele- ments to transfer forces, requiring lower lubrication and maintenance, but they are susceptible to impact damage. translation movements with the basic principle of wheel-rail systems
  • 5. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1217 In 2012 Author (Schumacher) divided control mechanisms of this type of dynamic structure in four main types of simple machines. 1. Rope and rod- allow rigid objects to be pushed or pulled using a rope and bar, applying the same amount of force in the same direction but at a different point. 2. Rope and pulley- direction of the force can be changed 3. Lever- allow to change the magnitude of the force 4. Inclined plane- change magnitude of force. Fig 8:-Examples of Control Mechanisms Machines 2.2.1.3 Control Mechanism To correlate the relation between mechanism and motion with type, direction and force of movement the present chart are followed. Fig 9:-To Change Direction of Movement Fig 10:-To Change Type of Movement
  • 6. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1218 Fig 11:-To Change Output Force and Speed 2.2.2 Load Bearing Structure’s Unlike static structures, the requirements of portable dynamic structures differ because movements are necessary and are part of its conversions, and issues such as stiffness, stability and resistance must not be simply addressed, but controlled. Stability is essential both in its “closed” and in its “open” positions (Schumacher, 2010).But to achieve transformation process folded kinetic structure need support machinery during movement. This generates high operating costs and compromises more easily a long-term operation of mechanisms and connections. Focused on transportation methods of dynamic folded structure; it restricts the dimensions of the folded building and the overall weight. If the buildings include auxiliary lifting points and vehicles are needed to promote displacement, the structure has to resist the stress generated by the movement. Considering the foundations is also an objective, it’s important to have the perfect level in the structure for the proper occupancy and the correct function of mechanisms. The mobile architecture can be placed in different locations with different contexts, and it is important that the foundation is flexible enough to adapt without improvisations. Fig 12:- An example of corner lifting points in containers Folded transformable structure, need to be capable to bear the load in three different moments: 1. The close position- usually when transports also occurs and it has to be stable during lifting and displacement; 2. The opening position- when transformation is taking place and structure is not stable; 3. The open position- where the transformation has been completed and components are locked in place and the stable structure is once again reached.
  • 7. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1219 Fig13: - Deployable positions of transformation of folded portable structure 2.2.2.1 Dynamically Self-erecting Structures The mechanism to achieve Dynamically Self-erecting Structures is the use of linked, folding supports in a cross-cross “X” pattern, known as a pantograph (or scissor mechanism) OR lever arm based structure. the motion is achieved by the application of pressure one side to deployed it to other side , elongating the crossing pattern, and propelling the structure in the deployable direction is depend on design of structure. The direction and form of the deployed structure can be defined by the angle and position of linkage between the bars. The most difficult point is to determine how much of opening each scissor will realize, how to achieve the precision needed at the end of deployment for the structure be perfect connected and stable. the movement of the scissor action can be hydraulic, pneumatic or mechanical (via a lead screw or rack and pinion system) and with the right control, specifications and leveling in site these applications can, not only put the structure in motion, but also control the opening of each mechanism. Fig 14:- Deployable Folded Portable Structure manufactured by tenfold engineering based on scissor mechanism. 2.2.2.2 Expandable Folded Portable Structure Expandable architecture refers to an architecture transformation which fundamentally affects the whole building form and where the components parts are pre-hinged and continuous, and remains so through transformation (Zuk and Clark, 1979). This can be also the characteristics of kinetic components and self-erecting structure, but the major difference is that in expandable architecture the basic elements are connected at all times and depend of each other to achieve transformation. Be sides these, this architecture may be referred as “expandable” and takes advantages of the combination of rigid and deformable elements for construction. Pre-hinged construction systems, usually with a kit form of auxiliary parts. Folding mechanism is commonly used in this system. A notable advantage is the little depth or thickness in transportation, being able to transport a larger quantity in a same vehicle. As the building is unfolded, the structure is also unfolded and within the envelope, it’s unstable and there is
  • 8. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1220 the need of auxiliary equipment. Once the unfolding process is completed, and the fixations and locks realized, the rigid elements have a load bearing capacity and are stable Fig 15:- Expandable Folded Portable Structure 2.2.2.3 Piers and Foundation The fixations and foundations of folded portable structure are probably the crucial part of a structure project. The correct leveling of the building is what can determine the correct function of connection mechanisms and mobile components for being transportable; a project needs to foresee the different location sites and possibilities that the building may encounter in throughout its life. There are multiple options when choosing piers and foundations, and all depends on the project and soil conditions of the terrain, but a few basic recommendations can be made. Base Pads Base pads are used as a base plate to eliminate deflection and preventing the piers and foot of sinking into the ground. The size of a pad is directly related with the item it supports, material and variation of load capacities. In the commercial cata- logue is possible to encounter pads with different materials that are light-weighed and low dimensioned, which favors the relocation and reuse(Figure 65). For piers are used plywood, metallic and ABS pads; for footing are used metallic and plastic; nevertheless, the more advertised and commercialized is the plastic and ABS bases, reassuring the lightweight properties and the capability of absorbing vibrations. Piers and Footing The principal differences of piers and footing are the load, the height and time of use locations- for faster relocating buildings, the footing system are easier to use . But booth should use the screw jacks mechanical devices to lift and leveling the buildings. The “jack” employs screw thread or hydraulic cylinder to lift heavy loads and apply great linear forces. Normally, screw jacks are simple mechanisms that need to be manually operated until reaching the grading desired, they can reach high load capacity (1.5 – 3tons) and, when threaded, high height (24 inches) . Although, they are not recom- mended for buildings that need complex grading adjustments because of the difficulties of an accurately assemble and risk situations for workers. They have great use for foot of buildings and kinetic components, in this last case, they can be an auxiliary support for the frame structure and help to lock the components in place. Fig 16:-Base Pads Fig 17:- Piers
  • 9. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1221 2.2.3 Planar Surface Components Surface elements of folded portable structure representing the active layer and inquiring the specifications necessity of covering materials, sealing joints and installation system in a structure and their relationship to the whole as: site, structure, skin, services, space plan, and stuff. structure is the load bearing elements, foundation and skeleton; skin is the exterior surface, such as siding and windows; services are the nervous systems of a building, such as its heating plant, wiring, and plumbing; space plan includes walls, flooring, and ceilings; and stuff includes lamps, chairs, appliances, bulletin boards, and paintings (brand, 1994). A good strategy to achieve this is to reduce the assembly parts, by using better specific materials that fulfill more performance requirements. Reducing assembly time and cost depending on methods and processes with a faster implementation and a less potential to failures Material Covering materials in this type of building should not only perform properly as enclosure, but they should also resist repeated movement and environmental changes before, during and after transformation (Asefi, 2010). Also, the skin contributes to the self-weight of the construction and in the dimensions of movable elements (Schumacher, 2010) and light-weight materials should be considered at all times. Industry offers a variety options with different resistance and rigidity characteristics and the shape alterations of the cover components need to be think of since the beginning of the project. Is the skin stable and moves with the structure, or is it flexible and cover the structure as it moves? Many factors of materials characteristics like Translucency, Fire,. Water-proof mechanical resistance, cleaning, insulation is important, recycling. 2.3 INTRODUCTION OF SUSTAINABLE STRUCTURE AND DESIGN PRINCIPAL OF SUSTAINABILITY. Introduction of Sustainable Structure:- Sustainable structure is the practice of creating structures using resources that are environmentally responsible and energy-efficient. It encompasses factors such as internal and external design, construction, operation, maintenance, renovation, and deconstruction. The aim of sustainable building design is to reduce the overall impact of the built environment on human health and the natural environment (Anonymous, 2014a).This design practice emphasizes efficiency of heating and cooling systems; alternative energy sources such as solar hot water, appropriate building siting, reused or recycled building materials; on-site power generation - solar technology, ground source heat pumps, wind power; rainwater harvesting for gardening, washing and aquifer recharge; and on-site waste management such as green roofs that filter and control storm water runoff (Yan and Stallions 2006). Sustainable building is the practice of creating structures using resources that are environmentally responsible and energy-efficient. It encompasses factors such as internal and external design, construction, operation, maintenance, renovation, and deconstruction. The aim of sustainable building design is to reduce the overall impact of the built environment on human health and the natural environment (Anonymous, 2014a). Fig 18:- Main goals for sustainable structure design (Anonymous, 2014a)
  • 10. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1222 Design Principal of Sustainability 2.4 EXISTING FOLDED PORTABLE STRUCTURE ANALYTICAL STUDY Fig 19:-Ten Fold Structure 1. Optimization of resources (natural and artificial): Structure that use natural durable, reclaimed and re-usable materials and resources can be designed. 2. Reduction of energy consumption: Designing bioclimatic buildings, having energy efficient construction solutions that use natural energy sources and local materials. Reducing transportation of materials. 3. Utilization of alternative energy sources: Buildings using wind, solar and geothermal energy as passive-active integrated systems can be designed. 4. Reduction of waste and emissions: To reduce and manage the pollution and waste, it can be used waste products, putrescible and non-polluting materials. 5. Improving people’s health and wellbeing: Fulfilling people’s social life and relations and enhancing their life quality, using of healthy materials, providing natural ventilation. 6.Reduction of building costs and maintenance: To reduce price and maintenance buildings having extended life cycles and technological solutions can be designed, by using reclaimed and re-used materials System Pantograph hybrid Structure Dynamically self-erecting Architect David Martyn Company Ten Fold Engineering Year Patent 2012 Location United Kingdom Use Stage 1. TEN FOLD STRUCTURE
  • 11. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1223 Fig 20:- Assembly of Ten Fold Structure Fig 21:- Transportation System of Ten Fold Structure TEN FOLD STRUCTURECOMPONENTS Movement Mechanisms  Deployment in 8 minute with 10 persons  pin-jointed linkage of lever arm(Scissor) with walls that perform specific useful moment repeatedly, precisely and reversibly in such a way that they can fold up, including folded roof and floor with each element counterbalancing the other so that very little power is needed to drive then Load Bearing Structure  It uses a double single scissor {Lever Arm} All the linkage can be driven by almost any one of the individual bars of the linkage by using hydraulic or rack and pinion mechanism. This gives them extreme versatility and flexibility in all application are obviates the need for complex locking and feedback system. Planar Surface Components  75-120mm free finished composite panels
  • 12. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1224 Transformable Design Strategies Design Expansion and Flexibility Expanded counterbalance mechanism from two side due to hydraulic mechanism and lever arm reliably Compactability and Transportability 64m2 of flexible, ready-to-use space delivered in 8 minutes from a standard truck The Module expands upwards and outwards simultaneously providing 32m2 of additional floor space Structural Stability and Deformability Stable at all times Architectural Obstruction The interior is used for storage of movable components Moveable internal walls and Exchangeable pods t Operating System Automatic using hydraulic mechanism. Construction and Operations Reliability and Safety The units are easily customized and readily adaptable to user and site Specifics. All units and their related Pods are modular, interconnect able and interchangeable and provide high quality, flexible space and facilities for living and working to suit user and site specifics in almost any environment or working sector Manufacture and Shipment industrial constructions under prefabrication premises Life-Expectancy TEN FOLD units are robust and resilient, long-life, well-insulated buildings designed to be moved and moved again but with the designed performance characteristics expected of a solid building. The units can be built to international standards and designed to comply with the broadest ranges of local construction codes Capital Cost 129000 dollar
  • 13. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1225 2.5 STUDIE ON FOLDED PORTABLE STRUCTURE BY DESIGN PRINCIPAL OF SUSTAINABILITY 3. CONCLUSIONS Folded Portable structures are a vast field of study, and each of the subjects cover in this research can be explored to study the basic concept of this type of type of structure and to study about sustainability principle and state that prefabricated structure has more capability to attain sustainability as compared conventional structure. Here the component of folded portable structure with their mechanical and movable connections properties and the relation with the structure and the movement realized can be studied. And with that study, analysis of existing ten folds structure are done on various parameters with the checking of it sustainability. This research aims to evaluate the technical means of a structure transformation of folded portable structure and design decisions required for it success. In order to better explain transformation from this technical perspective. 4. References 1) Kronenburg, R. 2003. Portable Architecture, Burlington: Elsevier. 2) Kronenburg, Robert. Flexible. Architecture that Responds to Change .London: Art Blume, 2007. Print. 3) Kronenburg, R.: 1997, Transportable Environments: Papers from the International Conference on Portable Architecture, E & FN Spoon, and London. 4) Zuk, William; Clark, Roger H. Kinetic Architecture. United States of America and Canada: Van Nostrand Reinhold Company, 1970. Print. 5) Barcelona, España, Transformable and transportable architecture: analysis of buildings components and Strategies for project design September, 2013. 6) Esra Lakot Alemdağ1, Özlem AYDIN1,A study of Shipping Containers as a Living Space in Context of Sustainability, 28.01.2015, Turkey. 1. Optimization of resources (natural and artificial): Tenfold Structure use durable, reclaimed and re-usable materials and resources and designed as a prefabricated structure. 2. Reduction of energy consumption: Tenfold is designed as a prefabricated structure constructed in factory so reduce and minimized construction waste and reduce transportation cost and save land as foundation are not stuck to ground. 4. Reduction of waste and emissions: Conventional building contributes to CO2 emission prefabricated structure with composite material panel reduce Contribution to emission and help to maintain ecological parameter balance 5. Improving people’s health and wellbeing: Tenfold structure provide comfort, luxurious life to the people by designing are able to done with peoples requirement and have ability to maintain people healthy 6.Reduction of building costs and maintenance: Cost of structure is high with low maintenance cost.