Medium Voltage Vacuum Contactor
--FVC6 type
--13.8kV/15/kV
Product brochure
2010/4
Zhejiang Farady Electric Co., Ltd.
ISO9001&ISO14001 certificated enterprise
++++General
Vacuum contactor uses vacuum interrupter to extinguish arc to frequently connect and cut off
normal working current. It is usually used for 6-40.5kV system AC motor in long distance
connection and disconnection.
++++Application
FVC series of Medium voltage vacuum AC contactors are widely used in coal, power,
metallurgy and textile. High building and other industry departments. Medium voltage vacuum
AC contactor is suitable for communication: 50-60HZ. rated voltage: 13.8Kv/15kV rated
current 63 to 630A feed network for long distance connection and Open circuit, and frequent
starting and stopping the use of AC motor. It is especially suitable for assembling with all
kinds of protective devices to form flameproof electromagnetic starter.
++++Product Feature:
• Main circuit
The vacuum switch tube uses products from well-known domestic manufacturers. The
technology is mature, the quality is reliable, and the market reputation is good.
The current rating of 630A adopts the double-acting connection of the end face and the
conductive clip, which has small resistance, low temperature rise, and more reliable.
The conductive row is beautiful, the cross-sectional area is better than that of similar
products, and a reinforcing plate is installed at the upper end of the fixed-end conductive
row to strengthen the connection strength between the copper row and the vacuum tube
and prevent the damage caused by copper row deformation.
• Electromagnetic system
It adopts a closed structure and is equipped with a heat dissipation window to become a
structurally complete electrical product. It fully satisfies the requirements for temperature
rise and the like, and it can prevent the ingestion of dust and ferromagnetic substances and
is safe to use. It is the unique structure of similar products.
Optimize the structure of the operation, reduce the start-up power of the coil and maintain
the power, so the temperature rise is low, the life is long, and it is more reliable.
Set the limit buffer in the limit position of the iron breaker to eliminate the hidden accidents
caused by the excessive amplitude of the rebound. At the same time, the auxiliary switch
starter also uses buffer to reduce the impact force and improve the reliability of the auxiliary
switch.
• Operation Mechanism
The shaft supports are flexible, the force is not stuck, and the axial movement is small,
improving the performance and consistency.
Reasonable operating mechanism to ensure that the vacuum tube moves the axial direction
of the conductive rod. Improved contactor performance and reliability. Makes the same
three-step, spring-jumping index better than similar products.
Increases the contact pressure of the main contact, improving electrical performance and
operating characteristics. The indicators are better than similar products.
The mechanical holding device is self-contained, structurally sound and more reliable to
use.
1
• Easy to use and maintain
The secondary circuit wiring terminals have function flags, and the alignment lines are
separated by a fixed color to prevent the connection error and facilitate the inspection of the
wiring. According to the user's needs, the terminal can be mounted on the front or back of
the machine. The number of auxiliary contacts can be combined according to the
requirements.
++++Technical specification
Performance parameters unit FVC6
Rated operating voltage(Ur) kV 15
Rated insulation level
1min Power frequency
withstand voltage(Ud)
kV 55
Impact withstand voltage (peak) kV 110
Rated frequency(fr) HZ 50/6
Rated operating current(Ie) A 160,250,400,630 630
Rated single capacitor bank
breaking current(C2 class)
A — 250
Rated back-to-back capacitor bank
breaking current(C2 class 类)
A — 100
Short-time withstand current
Rated short-time withstand
current(Ik)
A 10I
e
Rated peak withstand current
( )
kA 25I
Rated short circuit duration(tk) s 4
Rated load and overload
characteristics
(category AC4)100 Closing
operation
A 10I
e
(category AC4) 25 Sub-breaking
operation
A 8I
e
Rated withstand overload current
1s
A 15I
e
Rated withstand overload current
30s
A 6I
e
Main circuit contact resistance μΩ ≤200
Rated operating frequency
Electrical maintenance times/
h
300(Mechanical life (heavy/minute
cycle))100 Million times)
Mechanical maintenance 60(Mechanical life (heavy/minute
cycle)) 25 Million times)
Electrical durability (electric life)
2
AC3 Million
times
25(closing current 6Ie, breaking
current 1Ie)
AC4 Million
times
6(closing current 6Ie, breaking
current 1Ie)
Secondary circuit to ground
insulation withstand voltage
2000V50Hz(1min)
Control circuit
Rated voltage(Us)(85%~110%) V ac./dc. 110V、220V、380V
rated power(Ps)
Electrical maintenance
W
start up<1500W maintain<50W
Mechanical maintenance Closing<1500W Opening<600W
Operation time
Closing ms ≤200
Opening ms ≤60
Auxiliary switch
Rated insulation voltage V AC380V
Convention heating current A 10
Rated operating voltage V AC380V,DC250V
Rated operating current or AC-12/16A;AC-15/720VA;DC-
++++Control, auxiliary circuit
Control power supply voltage Us:ac./dc. 110V, 220V, 380V or customized according to user
requirements.
Control power supply: Electrically self-maintaining: Start <900W Hold <30W.
Mechanical self-holding: closing <800W opening <600W.
Auxiliary contacts: Provides auxiliary contacts for users. The conventional products are two
normally closed three normally open; up to five normally closed six normally open. The
machine is maintained as three normally closed three normally open; up to six normally
closed six normally open.
Auxiliary contact capacity: AC380V 6A; AC220V 10A.
Power frequency withstand voltage: 2kV (except components).
++++Mechnical characteristics
Open and close time ≤ 120ms.
Three-phase synchronization ≤ 2ms.
The minimum pull-in voltage is ≤85%Us and the maximum release voltage is
0% to 75%Us.
++++Overall and installation dimensions
3
4
5
++++Before order pls clarify of your requirement with our tech
Copyright 2014 Farady Electric
Zhejiang Farady Electric Co.,Ltd
TEL:0086-577-61722510/61777258
Fax:0086-577-61777257
Http://www.farady.cn
Email:info@farady.cn
Add:Xiangyang Industrial Zone,Liushi,Yueqing,Zhejiang,P.R.China,
325604

More Related Content

What's hot

Circuit breaker 1
Circuit breaker 1Circuit breaker 1
Circuit breaker 1
guribhullar
 
Flowchart for optimal design of dc machine and transfomer
Flowchart for optimal design of dc machine and transfomerFlowchart for optimal design of dc machine and transfomer
Flowchart for optimal design of dc machine and transfomer
Nisarg Amin
 
Stator core induction test
Stator core induction testStator core induction test
Stator core induction test
Donald Stephen
 
Circuit breakers
Circuit breakers Circuit breakers
Circuit breakers
Souvik Dolui
 
Circuitbreaker HIGH VOLTAGE CIRCUIT
Circuitbreaker HIGH VOLTAGE CIRCUITCircuitbreaker HIGH VOLTAGE CIRCUIT
Circuitbreaker HIGH VOLTAGE CIRCUIT
Hazem El-Henawy
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breaker
Karansinh Parmar
 
Circuit Breaker
Circuit BreakerCircuit Breaker
Circuit Breaker
Sukhendra Chaudhary
 
Air Blast & SF6 Circuit Breaker Design and Construction
Air Blast & SF6 Circuit Breaker Design and Construction Air Blast & SF6 Circuit Breaker Design and Construction
Air Blast & SF6 Circuit Breaker Design and Construction
anuphowlader1
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breaker
Priyankar Misra
 
Circuit breaker, Types of circuit breaker & different CB related questions
Circuit breaker, Types of circuit breaker & different CB related questionsCircuit breaker, Types of circuit breaker & different CB related questions
Circuit breaker, Types of circuit breaker & different CB related questions
Urooj Abid
 
circuit breaker
circuit breakercircuit breaker
circuit breaker
AbhishekLalkiya
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakers
ali raza
 
TURBO GENERATOR
TURBO GENERATORTURBO GENERATOR
TURBO GENERATOR
k,l polytechnic roorkee
 
Study of circuit breakers
Study of circuit breakersStudy of circuit breakers
Study of circuit breakers
SUDHEER KUMAR KALYANAM
 
high voltage circuit breaker
high voltage circuit breakerhigh voltage circuit breaker
high voltage circuit breaker
Hanif Pathan
 
9 a couplings introduction
9 a couplings   introduction9 a couplings   introduction
9 a couplings introduction
Dr.R. SELVAM
 
Circuit Breaker
Circuit BreakerCircuit Breaker
Circuit Breaker
Anshaj Malhotra
 
Project on fabrication and machining of turnbuckle
Project on fabrication and machining of turnbuckleProject on fabrication and machining of turnbuckle
Project on fabrication and machining of turnbuckle
Köushik Thë Hěĭï Prïnčê
 
Circuitbreakers 140829234332-phpapp01
Circuitbreakers 140829234332-phpapp01Circuitbreakers 140829234332-phpapp01
Circuitbreakers 140829234332-phpapp01
rana usman
 
Vb4 series indoor vacuum circuit breaker
Vb4 series indoor vacuum circuit breakerVb4 series indoor vacuum circuit breaker
Vb4 series indoor vacuum circuit breaker
JoeChueng
 

What's hot (20)

Circuit breaker 1
Circuit breaker 1Circuit breaker 1
Circuit breaker 1
 
Flowchart for optimal design of dc machine and transfomer
Flowchart for optimal design of dc machine and transfomerFlowchart for optimal design of dc machine and transfomer
Flowchart for optimal design of dc machine and transfomer
 
Stator core induction test
Stator core induction testStator core induction test
Stator core induction test
 
Circuit breakers
Circuit breakers Circuit breakers
Circuit breakers
 
Circuitbreaker HIGH VOLTAGE CIRCUIT
Circuitbreaker HIGH VOLTAGE CIRCUITCircuitbreaker HIGH VOLTAGE CIRCUIT
Circuitbreaker HIGH VOLTAGE CIRCUIT
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breaker
 
Circuit Breaker
Circuit BreakerCircuit Breaker
Circuit Breaker
 
Air Blast & SF6 Circuit Breaker Design and Construction
Air Blast & SF6 Circuit Breaker Design and Construction Air Blast & SF6 Circuit Breaker Design and Construction
Air Blast & SF6 Circuit Breaker Design and Construction
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breaker
 
Circuit breaker, Types of circuit breaker & different CB related questions
Circuit breaker, Types of circuit breaker & different CB related questionsCircuit breaker, Types of circuit breaker & different CB related questions
Circuit breaker, Types of circuit breaker & different CB related questions
 
circuit breaker
circuit breakercircuit breaker
circuit breaker
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakers
 
TURBO GENERATOR
TURBO GENERATORTURBO GENERATOR
TURBO GENERATOR
 
Study of circuit breakers
Study of circuit breakersStudy of circuit breakers
Study of circuit breakers
 
high voltage circuit breaker
high voltage circuit breakerhigh voltage circuit breaker
high voltage circuit breaker
 
9 a couplings introduction
9 a couplings   introduction9 a couplings   introduction
9 a couplings introduction
 
Circuit Breaker
Circuit BreakerCircuit Breaker
Circuit Breaker
 
Project on fabrication and machining of turnbuckle
Project on fabrication and machining of turnbuckleProject on fabrication and machining of turnbuckle
Project on fabrication and machining of turnbuckle
 
Circuitbreakers 140829234332-phpapp01
Circuitbreakers 140829234332-phpapp01Circuitbreakers 140829234332-phpapp01
Circuitbreakers 140829234332-phpapp01
 
Vb4 series indoor vacuum circuit breaker
Vb4 series indoor vacuum circuit breakerVb4 series indoor vacuum circuit breaker
Vb4 series indoor vacuum circuit breaker
 

Similar to Fvc6 vacuum contactor

36kV high voltage drawout VCB type switchgear
36kV high voltage drawout VCB type switchgear36kV high voltage drawout VCB type switchgear
36kV high voltage drawout VCB type switchgear
Rockwill T&D Group Manufacturer,Contractor, OEM, ODM
 
Gis91
Gis91Gis91
Gis91
nknathan
 
Kyn28 metal clad switchgear
Kyn28 metal clad switchgearKyn28 metal clad switchgear
Kyn28 metal clad switchgear
JoeChueng
 
New VD4-Rockwill
New VD4-RockwillNew VD4-Rockwill
Vb4p series indoor vacuum circuit breaker
Vb4p series indoor vacuum circuit breakerVb4p series indoor vacuum circuit breaker
Vb4p series indoor vacuum circuit breaker
JoeChueng
 
KYN28 12kV Medium voltage metal clad switchgear
KYN28 12kV Medium voltage metal clad switchgearKYN28 12kV Medium voltage metal clad switchgear
KYN28 12kV Medium voltage metal clad switchgear
Rockwill T&D Group Manufacturer,Contractor, OEM, ODM
 
Ls catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vn
Ls catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vnLs catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vn
Ls catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vn
Dien Ha The
 
Farady Indoor vacuum circuit breaker
Farady Indoor vacuum circuit breakerFarady Indoor vacuum circuit breaker
Farady Indoor vacuum circuit breaker
AUTO RECLOSER
 
Neutral grounding resistors ngr
Neutral grounding resistors  ngrNeutral grounding resistors  ngr
Neutral grounding resistors ngr
JoeChueng
 
Ac Test Transformer
Ac Test TransformerAc Test Transformer
Ac Test Transformer
kennypowerhv
 
Report on 220kv substation at Jassure
Report on 220kv substation at JassureReport on 220kv substation at Jassure
Report on 220kv substation at Jassure
Shuvam Pathania
 
RK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdfRK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdf
RK Engineering
 
Standing type GIS RMU
Standing type GIS RMUStanding type GIS RMU
Standing type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unitStanding type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unit
Rockwill T&D Group Manufacturer,Contractor, OEM, ODM
 
Catalog cs switch disconnectors_dienhathe.vn
Catalog cs switch disconnectors_dienhathe.vnCatalog cs switch disconnectors_dienhathe.vn
Catalog cs switch disconnectors_dienhathe.vn
Dien Ha The
 
havells ppt
havells ppthavells ppt
havells ppt
Raj Sharma
 
Air insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kvAir insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kv
AUTO RECLOSER
 
Catalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.comCatalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.com
Beeteco
 
Catalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo PhươngCatalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo Phương
CTY TNHH HẠO PHƯƠNG
 
Power supply required for electrical welding
Power supply required for electrical weldingPower supply required for electrical welding
Power supply required for electrical welding
SawanRathawa
 

Similar to Fvc6 vacuum contactor (20)

36kV high voltage drawout VCB type switchgear
36kV high voltage drawout VCB type switchgear36kV high voltage drawout VCB type switchgear
36kV high voltage drawout VCB type switchgear
 
Gis91
Gis91Gis91
Gis91
 
Kyn28 metal clad switchgear
Kyn28 metal clad switchgearKyn28 metal clad switchgear
Kyn28 metal clad switchgear
 
New VD4-Rockwill
New VD4-RockwillNew VD4-Rockwill
New VD4-Rockwill
 
Vb4p series indoor vacuum circuit breaker
Vb4p series indoor vacuum circuit breakerVb4p series indoor vacuum circuit breaker
Vb4p series indoor vacuum circuit breaker
 
KYN28 12kV Medium voltage metal clad switchgear
KYN28 12kV Medium voltage metal clad switchgearKYN28 12kV Medium voltage metal clad switchgear
KYN28 12kV Medium voltage metal clad switchgear
 
Ls catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vn
Ls catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vnLs catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vn
Ls catalog thiet bi dien vcs ls medium voltage-vacuum contactor_dienhathe.vn
 
Farady Indoor vacuum circuit breaker
Farady Indoor vacuum circuit breakerFarady Indoor vacuum circuit breaker
Farady Indoor vacuum circuit breaker
 
Neutral grounding resistors ngr
Neutral grounding resistors  ngrNeutral grounding resistors  ngr
Neutral grounding resistors ngr
 
Ac Test Transformer
Ac Test TransformerAc Test Transformer
Ac Test Transformer
 
Report on 220kv substation at Jassure
Report on 220kv substation at JassureReport on 220kv substation at Jassure
Report on 220kv substation at Jassure
 
RK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdfRK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdf
 
Standing type GIS RMU
Standing type GIS RMUStanding type GIS RMU
Standing type GIS RMU
 
Standing type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unitStanding type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unit
 
Catalog cs switch disconnectors_dienhathe.vn
Catalog cs switch disconnectors_dienhathe.vnCatalog cs switch disconnectors_dienhathe.vn
Catalog cs switch disconnectors_dienhathe.vn
 
havells ppt
havells ppthavells ppt
havells ppt
 
Air insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kvAir insulated sf6 ring main unit 36kv
Air insulated sf6 ring main unit 36kv
 
Catalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.comCatalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.com
 
Catalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo PhươngCatalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo Phương
 
Power supply required for electrical welding
Power supply required for electrical weldingPower supply required for electrical welding
Power supply required for electrical welding
 

More from JoeChueng

Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulator
JoeChueng
 
Ys10 pad mounted transformer
Ys10 pad mounted transformerYs10 pad mounted transformer
Ys10 pad mounted transformer
JoeChueng
 
Padmounted transformer
Padmounted transformerPadmounted transformer
Padmounted transformer
JoeChueng
 
Prefabricated compact transformer
Prefabricated compact transformerPrefabricated compact transformer
Prefabricated compact transformer
JoeChueng
 
VR-8 step voltage regulator
VR-8 step voltage regulatorVR-8 step voltage regulator
VR-8 step voltage regulator
JoeChueng
 
Automatic voltage regulator(avr)
Automatic voltage regulator(avr)Automatic voltage regulator(avr)
Automatic voltage regulator(avr)
JoeChueng
 
Dry type autotransformer
Dry type autotransformerDry type autotransformer
Dry type autotransformer
JoeChueng
 
Cast resin dry type transformer
Cast resin dry type transformerCast resin dry type transformer
Cast resin dry type transformer
JoeChueng
 
Oil immersed transformer
Oil immersed transformerOil immersed transformer
Oil immersed transformer
JoeChueng
 
Ltvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulatorLtvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulator
JoeChueng
 
Lsvr lt step voltage regulator
Lsvr lt step voltage regulatorLsvr lt step voltage regulator
Lsvr lt step voltage regulator
JoeChueng
 
Single phase pole mounted transformer
Single phase pole mounted transformerSingle phase pole mounted transformer
Single phase pole mounted transformer
JoeChueng
 
D11 single phase overhead distribution transformer
D11 single phase overhead distribution transformerD11 single phase overhead distribution transformer
D11 single phase overhead distribution transformer
JoeChueng
 
Fgw1 air break switch
Fgw1 air break switchFgw1 air break switch
Fgw1 air break switch
JoeChueng
 
Hxgn17 vacuum type ring main unit
Hxgn17 vacuum type ring main unitHxgn17 vacuum type ring main unit
Hxgn17 vacuum type ring main unit
JoeChueng
 
Jxf distribution box
Jxf distribution boxJxf distribution box
Jxf distribution box
JoeChueng
 
Xl21 distribution box
Xl21 distribution boxXl21 distribution box
Xl21 distribution box
JoeChueng
 
Power factor corrector
Power factor correctorPower factor corrector
Power factor corrector
JoeChueng
 
Mns lv switchgear
Mns lv switchgearMns lv switchgear
Mns lv switchgear
JoeChueng
 
Gcs lv switchgear draw out type
Gcs lv switchgear draw out typeGcs lv switchgear draw out type
Gcs lv switchgear draw out type
JoeChueng
 

More from JoeChueng (20)

Automatic reactive voltage regulator
Automatic reactive voltage regulatorAutomatic reactive voltage regulator
Automatic reactive voltage regulator
 
Ys10 pad mounted transformer
Ys10 pad mounted transformerYs10 pad mounted transformer
Ys10 pad mounted transformer
 
Padmounted transformer
Padmounted transformerPadmounted transformer
Padmounted transformer
 
Prefabricated compact transformer
Prefabricated compact transformerPrefabricated compact transformer
Prefabricated compact transformer
 
VR-8 step voltage regulator
VR-8 step voltage regulatorVR-8 step voltage regulator
VR-8 step voltage regulator
 
Automatic voltage regulator(avr)
Automatic voltage regulator(avr)Automatic voltage regulator(avr)
Automatic voltage regulator(avr)
 
Dry type autotransformer
Dry type autotransformerDry type autotransformer
Dry type autotransformer
 
Cast resin dry type transformer
Cast resin dry type transformerCast resin dry type transformer
Cast resin dry type transformer
 
Oil immersed transformer
Oil immersed transformerOil immersed transformer
Oil immersed transformer
 
Ltvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulatorLtvr overhead line lt voltage regulator
Ltvr overhead line lt voltage regulator
 
Lsvr lt step voltage regulator
Lsvr lt step voltage regulatorLsvr lt step voltage regulator
Lsvr lt step voltage regulator
 
Single phase pole mounted transformer
Single phase pole mounted transformerSingle phase pole mounted transformer
Single phase pole mounted transformer
 
D11 single phase overhead distribution transformer
D11 single phase overhead distribution transformerD11 single phase overhead distribution transformer
D11 single phase overhead distribution transformer
 
Fgw1 air break switch
Fgw1 air break switchFgw1 air break switch
Fgw1 air break switch
 
Hxgn17 vacuum type ring main unit
Hxgn17 vacuum type ring main unitHxgn17 vacuum type ring main unit
Hxgn17 vacuum type ring main unit
 
Jxf distribution box
Jxf distribution boxJxf distribution box
Jxf distribution box
 
Xl21 distribution box
Xl21 distribution boxXl21 distribution box
Xl21 distribution box
 
Power factor corrector
Power factor correctorPower factor corrector
Power factor corrector
 
Mns lv switchgear
Mns lv switchgearMns lv switchgear
Mns lv switchgear
 
Gcs lv switchgear draw out type
Gcs lv switchgear draw out typeGcs lv switchgear draw out type
Gcs lv switchgear draw out type
 

Recently uploaded

官方认证美国密歇根州立大学毕业证学位证书原版一模一样
官方认证美国密歇根州立大学毕业证学位证书原版一模一样官方认证美国密歇根州立大学毕业证学位证书原版一模一样
官方认证美国密歇根州立大学毕业证学位证书原版一模一样
171ticu
 
学校原版美国波士顿大学毕业证学历学位证书原版一模一样
学校原版美国波士顿大学毕业证学历学位证书原版一模一样学校原版美国波士顿大学毕业证学历学位证书原版一模一样
学校原版美国波士顿大学毕业证学历学位证书原版一模一样
171ticu
 
Properties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptxProperties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptx
MDSABBIROJJAMANPAYEL
 
A review on techniques and modelling methodologies used for checking electrom...
A review on techniques and modelling methodologies used for checking electrom...A review on techniques and modelling methodologies used for checking electrom...
A review on techniques and modelling methodologies used for checking electrom...
nooriasukmaningtyas
 
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student MemberIEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
VICTOR MAESTRE RAMIREZ
 
Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...
Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...
Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...
University of Maribor
 
BPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdf
BPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdfBPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdf
BPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdf
MIGUELANGEL966976
 
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
insn4465
 
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
IJECEIAES
 
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsKuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
Victor Morales
 
22CYT12-Unit-V-E Waste and its Management.ppt
22CYT12-Unit-V-E Waste and its Management.ppt22CYT12-Unit-V-E Waste and its Management.ppt
22CYT12-Unit-V-E Waste and its Management.ppt
KrishnaveniKrishnara1
 
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
IJECEIAES
 
2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf
2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf
2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf
Yasser Mahgoub
 
TIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEM
TIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEMTIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEM
TIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEM
HODECEDSIET
 
ML Based Model for NIDS MSc Updated Presentation.v2.pptx
ML Based Model for NIDS MSc Updated Presentation.v2.pptxML Based Model for NIDS MSc Updated Presentation.v2.pptx
ML Based Model for NIDS MSc Updated Presentation.v2.pptx
JamalHussainArman
 
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
ihlasbinance2003
 
Engineering Drawings Lecture Detail Drawings 2014.pdf
Engineering Drawings Lecture Detail Drawings 2014.pdfEngineering Drawings Lecture Detail Drawings 2014.pdf
Engineering Drawings Lecture Detail Drawings 2014.pdf
abbyasa1014
 
basic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdfbasic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdf
NidhalKahouli2
 
Textile Chemical Processing and Dyeing.pdf
Textile Chemical Processing and Dyeing.pdfTextile Chemical Processing and Dyeing.pdf
Textile Chemical Processing and Dyeing.pdf
NazakatAliKhoso2
 
Engine Lubrication performance System.pdf
Engine Lubrication performance System.pdfEngine Lubrication performance System.pdf
Engine Lubrication performance System.pdf
mamamaam477
 

Recently uploaded (20)

官方认证美国密歇根州立大学毕业证学位证书原版一模一样
官方认证美国密歇根州立大学毕业证学位证书原版一模一样官方认证美国密歇根州立大学毕业证学位证书原版一模一样
官方认证美国密歇根州立大学毕业证学位证书原版一模一样
 
学校原版美国波士顿大学毕业证学历学位证书原版一模一样
学校原版美国波士顿大学毕业证学历学位证书原版一模一样学校原版美国波士顿大学毕业证学历学位证书原版一模一样
学校原版美国波士顿大学毕业证学历学位证书原版一模一样
 
Properties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptxProperties Railway Sleepers and Test.pptx
Properties Railway Sleepers and Test.pptx
 
A review on techniques and modelling methodologies used for checking electrom...
A review on techniques and modelling methodologies used for checking electrom...A review on techniques and modelling methodologies used for checking electrom...
A review on techniques and modelling methodologies used for checking electrom...
 
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student MemberIEEE Aerospace and Electronic Systems Society as a Graduate Student Member
IEEE Aerospace and Electronic Systems Society as a Graduate Student Member
 
Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...
Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...
Presentation of IEEE Slovenia CIS (Computational Intelligence Society) Chapte...
 
BPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdf
BPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdfBPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdf
BPV-GUI-01-Guide-for-ASME-Review-Teams-(General)-10-10-2023.pdf
 
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
哪里办理(csu毕业证书)查尔斯特大学毕业证硕士学历原版一模一样
 
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
Electric vehicle and photovoltaic advanced roles in enhancing the financial p...
 
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressionsKuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
KuberTENes Birthday Bash Guadalajara - K8sGPT first impressions
 
22CYT12-Unit-V-E Waste and its Management.ppt
22CYT12-Unit-V-E Waste and its Management.ppt22CYT12-Unit-V-E Waste and its Management.ppt
22CYT12-Unit-V-E Waste and its Management.ppt
 
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
Redefining brain tumor segmentation: a cutting-edge convolutional neural netw...
 
2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf
2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf
2008 BUILDING CONSTRUCTION Illustrated - Ching Chapter 02 The Building.pdf
 
TIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEM
TIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEMTIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEM
TIME DIVISION MULTIPLEXING TECHNIQUE FOR COMMUNICATION SYSTEM
 
ML Based Model for NIDS MSc Updated Presentation.v2.pptx
ML Based Model for NIDS MSc Updated Presentation.v2.pptxML Based Model for NIDS MSc Updated Presentation.v2.pptx
ML Based Model for NIDS MSc Updated Presentation.v2.pptx
 
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
5214-1693458878915-Unit 6 2023 to 2024 academic year assignment (AutoRecovere...
 
Engineering Drawings Lecture Detail Drawings 2014.pdf
Engineering Drawings Lecture Detail Drawings 2014.pdfEngineering Drawings Lecture Detail Drawings 2014.pdf
Engineering Drawings Lecture Detail Drawings 2014.pdf
 
basic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdfbasic-wireline-operations-course-mahmoud-f-radwan.pdf
basic-wireline-operations-course-mahmoud-f-radwan.pdf
 
Textile Chemical Processing and Dyeing.pdf
Textile Chemical Processing and Dyeing.pdfTextile Chemical Processing and Dyeing.pdf
Textile Chemical Processing and Dyeing.pdf
 
Engine Lubrication performance System.pdf
Engine Lubrication performance System.pdfEngine Lubrication performance System.pdf
Engine Lubrication performance System.pdf
 

Fvc6 vacuum contactor

  • 1. Medium Voltage Vacuum Contactor --FVC6 type --13.8kV/15/kV Product brochure 2010/4 Zhejiang Farady Electric Co., Ltd. ISO9001&ISO14001 certificated enterprise
  • 2. ++++General Vacuum contactor uses vacuum interrupter to extinguish arc to frequently connect and cut off normal working current. It is usually used for 6-40.5kV system AC motor in long distance connection and disconnection. ++++Application FVC series of Medium voltage vacuum AC contactors are widely used in coal, power, metallurgy and textile. High building and other industry departments. Medium voltage vacuum AC contactor is suitable for communication: 50-60HZ. rated voltage: 13.8Kv/15kV rated current 63 to 630A feed network for long distance connection and Open circuit, and frequent starting and stopping the use of AC motor. It is especially suitable for assembling with all kinds of protective devices to form flameproof electromagnetic starter. ++++Product Feature: • Main circuit The vacuum switch tube uses products from well-known domestic manufacturers. The technology is mature, the quality is reliable, and the market reputation is good. The current rating of 630A adopts the double-acting connection of the end face and the conductive clip, which has small resistance, low temperature rise, and more reliable. The conductive row is beautiful, the cross-sectional area is better than that of similar products, and a reinforcing plate is installed at the upper end of the fixed-end conductive row to strengthen the connection strength between the copper row and the vacuum tube and prevent the damage caused by copper row deformation. • Electromagnetic system It adopts a closed structure and is equipped with a heat dissipation window to become a structurally complete electrical product. It fully satisfies the requirements for temperature rise and the like, and it can prevent the ingestion of dust and ferromagnetic substances and is safe to use. It is the unique structure of similar products. Optimize the structure of the operation, reduce the start-up power of the coil and maintain the power, so the temperature rise is low, the life is long, and it is more reliable. Set the limit buffer in the limit position of the iron breaker to eliminate the hidden accidents caused by the excessive amplitude of the rebound. At the same time, the auxiliary switch starter also uses buffer to reduce the impact force and improve the reliability of the auxiliary switch. • Operation Mechanism The shaft supports are flexible, the force is not stuck, and the axial movement is small, improving the performance and consistency. Reasonable operating mechanism to ensure that the vacuum tube moves the axial direction of the conductive rod. Improved contactor performance and reliability. Makes the same three-step, spring-jumping index better than similar products. Increases the contact pressure of the main contact, improving electrical performance and operating characteristics. The indicators are better than similar products. The mechanical holding device is self-contained, structurally sound and more reliable to use.
  • 3. 1 • Easy to use and maintain The secondary circuit wiring terminals have function flags, and the alignment lines are separated by a fixed color to prevent the connection error and facilitate the inspection of the wiring. According to the user's needs, the terminal can be mounted on the front or back of the machine. The number of auxiliary contacts can be combined according to the requirements. ++++Technical specification Performance parameters unit FVC6 Rated operating voltage(Ur) kV 15 Rated insulation level 1min Power frequency withstand voltage(Ud) kV 55 Impact withstand voltage (peak) kV 110 Rated frequency(fr) HZ 50/6 Rated operating current(Ie) A 160,250,400,630 630 Rated single capacitor bank breaking current(C2 class) A — 250 Rated back-to-back capacitor bank breaking current(C2 class 类) A — 100 Short-time withstand current Rated short-time withstand current(Ik) A 10I e Rated peak withstand current ( ) kA 25I Rated short circuit duration(tk) s 4 Rated load and overload characteristics (category AC4)100 Closing operation A 10I e (category AC4) 25 Sub-breaking operation A 8I e Rated withstand overload current 1s A 15I e Rated withstand overload current 30s A 6I e Main circuit contact resistance μΩ ≤200 Rated operating frequency Electrical maintenance times/ h 300(Mechanical life (heavy/minute cycle))100 Million times) Mechanical maintenance 60(Mechanical life (heavy/minute cycle)) 25 Million times) Electrical durability (electric life)
  • 4. 2 AC3 Million times 25(closing current 6Ie, breaking current 1Ie) AC4 Million times 6(closing current 6Ie, breaking current 1Ie) Secondary circuit to ground insulation withstand voltage 2000V50Hz(1min) Control circuit Rated voltage(Us)(85%~110%) V ac./dc. 110V、220V、380V rated power(Ps) Electrical maintenance W start up<1500W maintain<50W Mechanical maintenance Closing<1500W Opening<600W Operation time Closing ms ≤200 Opening ms ≤60 Auxiliary switch Rated insulation voltage V AC380V Convention heating current A 10 Rated operating voltage V AC380V,DC250V Rated operating current or AC-12/16A;AC-15/720VA;DC- ++++Control, auxiliary circuit Control power supply voltage Us:ac./dc. 110V, 220V, 380V or customized according to user requirements. Control power supply: Electrically self-maintaining: Start <900W Hold <30W. Mechanical self-holding: closing <800W opening <600W. Auxiliary contacts: Provides auxiliary contacts for users. The conventional products are two normally closed three normally open; up to five normally closed six normally open. The machine is maintained as three normally closed three normally open; up to six normally closed six normally open. Auxiliary contact capacity: AC380V 6A; AC220V 10A. Power frequency withstand voltage: 2kV (except components). ++++Mechnical characteristics Open and close time ≤ 120ms. Three-phase synchronization ≤ 2ms. The minimum pull-in voltage is ≤85%Us and the maximum release voltage is 0% to 75%Us. ++++Overall and installation dimensions
  • 5. 3
  • 6. 4
  • 7. 5 ++++Before order pls clarify of your requirement with our tech Copyright 2014 Farady Electric Zhejiang Farady Electric Co.,Ltd TEL:0086-577-61722510/61777258 Fax:0086-577-61777257 Http://www.farady.cn Email:info@farady.cn Add:Xiangyang Industrial Zone,Liushi,Yueqing,Zhejiang,P.R.China, 325604