1. The document outlines requirements and notes for contractors working on a construction project.
2. Contractors must verify existing conditions, comply with all codes and regulations, and obtain approvals from the owner's representative and landlord before beginning any work.
3. The contractor is responsible for maintaining safety standards, site cleanliness, and protecting existing structures not part of the project scope.
Elements of interior design, history,importance, main elements of interior design- line, shape, space, form,texture, colour in detail, their uses and charecteristics in interior design.method of achieving nice composition using these elements vs nice examples and illustration.
This document discusses the types and purposes of architectural drawings. It begins by defining drawings and their uses. It then describes the different types of architectural drawings, including concept sketches, survey drawings, presentation drawings, municipal drawings, working drawings, and record drawings. For each type of drawing, it provides a brief explanation of its purpose. It also discusses the components and standards of architectural drawings, such as site plans, floor plans, elevations, and sections. Overall, the document provides a high-level overview of the key types of drawings used in architectural design and construction projects.
The document discusses curtain wall systems. It begins with an introduction defining a curtain wall system as a non-structural outer covering that keeps weather and occupants in/out. The history notes that curtain walls emerged as exterior walls became non-load bearing. It describes the components of curtain walls including mullions, transoms, glass, and other materials. Functions are listed as protecting interiors from the environment while providing lighting and occupant comfort. The document also covers installation systems, loads, maintenance, and provides case studies of curtain wall implementations.
The document provides information about the growing field of interior design in Malaysia. It discusses what interior design is, what interior designers do, and the skills and knowledge required to work in the field. Some key points include: interior design involves designing the interior spaces of buildings; interior designers work with architects, clients, and contractors; they must have good organizational and project management skills; and interior design degrees cover subjects like design history, modeling, materials, and more. The career offers opportunities in both commercial and residential design firms.
This document summarizes 8 popular interior design styles: Mid-Century Modern, Industrial, Nautical, Scandinavian, Bohemian, Farmhouse, Urban Modern, and Shabby Chic. Mid-Century Modern features refined lines, minimalist silhouettes and natural shapes in neutral or bold colors. Industrial emphasizes exposed steel and wood with distressed elements and exposed brick. Nautical has a warm, beach house feel using white, sand and blue colors with unfinished wood.
Mood boards are collages used by designers to convey design concepts and themes to clients. They can include photos, sketches, colors, fabrics, and other materials. Mood boards help designers explore aesthetics like photography style, color palettes, patterns and overall look. They allow designers to present broad concepts to clients and get feedback before fully developing a design in the wrong direction.
The presentation covered the design of swimming pool chairs. It discussed anthropometry and ergonomics in furniture design. Different types of chairs were presented, including rocking, ball, bar, chaise lounge, and club chairs. The main topic was swimming pool chairs designed with seashell concepts for a pool near the sea. Dimensions and materials like synthetic rattan and aluminum were specified. The process of making furniture from sketch to final production was outlined. Advantages of the pool chairs like durability both indoors and outdoors were highlighted.
Elements of interior design, history,importance, main elements of interior design- line, shape, space, form,texture, colour in detail, their uses and charecteristics in interior design.method of achieving nice composition using these elements vs nice examples and illustration.
This document discusses the types and purposes of architectural drawings. It begins by defining drawings and their uses. It then describes the different types of architectural drawings, including concept sketches, survey drawings, presentation drawings, municipal drawings, working drawings, and record drawings. For each type of drawing, it provides a brief explanation of its purpose. It also discusses the components and standards of architectural drawings, such as site plans, floor plans, elevations, and sections. Overall, the document provides a high-level overview of the key types of drawings used in architectural design and construction projects.
The document discusses curtain wall systems. It begins with an introduction defining a curtain wall system as a non-structural outer covering that keeps weather and occupants in/out. The history notes that curtain walls emerged as exterior walls became non-load bearing. It describes the components of curtain walls including mullions, transoms, glass, and other materials. Functions are listed as protecting interiors from the environment while providing lighting and occupant comfort. The document also covers installation systems, loads, maintenance, and provides case studies of curtain wall implementations.
The document provides information about the growing field of interior design in Malaysia. It discusses what interior design is, what interior designers do, and the skills and knowledge required to work in the field. Some key points include: interior design involves designing the interior spaces of buildings; interior designers work with architects, clients, and contractors; they must have good organizational and project management skills; and interior design degrees cover subjects like design history, modeling, materials, and more. The career offers opportunities in both commercial and residential design firms.
This document summarizes 8 popular interior design styles: Mid-Century Modern, Industrial, Nautical, Scandinavian, Bohemian, Farmhouse, Urban Modern, and Shabby Chic. Mid-Century Modern features refined lines, minimalist silhouettes and natural shapes in neutral or bold colors. Industrial emphasizes exposed steel and wood with distressed elements and exposed brick. Nautical has a warm, beach house feel using white, sand and blue colors with unfinished wood.
Mood boards are collages used by designers to convey design concepts and themes to clients. They can include photos, sketches, colors, fabrics, and other materials. Mood boards help designers explore aesthetics like photography style, color palettes, patterns and overall look. They allow designers to present broad concepts to clients and get feedback before fully developing a design in the wrong direction.
The presentation covered the design of swimming pool chairs. It discussed anthropometry and ergonomics in furniture design. Different types of chairs were presented, including rocking, ball, bar, chaise lounge, and club chairs. The main topic was swimming pool chairs designed with seashell concepts for a pool near the sea. Dimensions and materials like synthetic rattan and aluminum were specified. The process of making furniture from sketch to final production was outlined. Advantages of the pool chairs like durability both indoors and outdoors were highlighted.
The document discusses the key elements of interior design: line, space, shape, form, texture, and color. It provides examples and definitions for each element. Line can be used to create movement, harmony, and set form and shape. Space can be positive (filled) or negative (empty). Shape is defined by its dimensions while form includes depth. Texture can be tactile or visual. Color is influenced by hue, value, and intensity and can be organized by primary, secondary, tertiary, complementary, or monochromatic schemes.
The document discusses different types of wall panelling materials and their uses. It describes various panelling materials like wood, metal, acoustic and structural panels. Wood panelling provides insulation and decorative appearance. Panelling is used to cover walls for aesthetic purposes and can provide insulation, soundproofing and reduce construction costs. Common panelling materials mentioned include wood, metal, laminate and tileboard panels.
This document contains definitions and explanations of various climatic and meteorological concepts. It discusses factors that determine climate like temperature, precipitation, altitude, latitude, winds and more. It also defines terms like weather, humidity, wind, atmospheric pressure and how they impact human thermal comfort and building design. Key climatic classifications and methods to assess human comfort like effective temperature and clothing insulation are also summarized.
Metal Cladding has provided coating applications to industries since 1943. The document discusses different types of cladding materials like wood, concrete, stone, and metals. It focuses on metal cladding, noting that metals provide strong and durable protection for buildings while also allowing for aesthetic versatility. Specific metals discussed include aluminum, steel, and copper, outlining their common uses, benefits, and drawbacks for cladding.
Laurie Baker was a British architect who came to India in 1945 as a missionary. He lived and worked in India for over 50 years, obtaining Indian citizenship in 1989. Baker is renowned for his initiatives in low-cost housing and sustainable architecture using locally available materials. Some key aspects of his work included using cost-effective materials like brick, laterite, mud and cow dung in innovative construction techniques like rat trap bond. He designed over 1000 residences and 40 other buildings in Kerala emphasizing natural ventilation, privacy and historical influences. Baker received the Padma Shri award in 1990 for his contributions to architecture.
The document discusses interior space and how it is defined and structured. Architectural elements like columns, walls, floors and roofs are used to articulate and delineate space. Structural systems like linear, planar and volumetric approaches influence the dimensions and arrangement of interior spaces. Interior design elements like partitions, ceilings, furniture, lighting and finishes are also used to further define spaces and influence spatial qualities within the overall architectural framework.
Interior architecture is the process of designing the interior spaces of buildings, taking into account how people will use and interact with the structural spaces. An interior designer's responsibilities include meeting with clients to understand their needs and budget, developing design concepts, creating drawings and finding furnishings. There are several types of interior design specializations including residential, commercial, hospitality, healthcare, universal and exhibition design. To be an interior designer requires creativity, practical and project management skills, as well as the ability to communicate effectively and find solutions within clients' budgets.
Interior design is the process of shaping the experience of interior space, through the manipulation of spatial volume as well as surface treatment for the betterment of human functionality.
The Bidani House project demonstrates how to design a climate-responsive building on a constrained urban site. Located in Faridabad's composite climate zone, the house has large temperature swings throughout the year. Key sustainable features include developing the house form around a central courtyard to act as a heat sink, using buffer spaces on the overheated southwestern exposure, allowing solar penetration according to seasonal changes through the building form, and using local stone for thermal mass to moderate temperature swings. The project shows how responsive design is possible even on a fixed small urban site.
furniture use , materials , market survey in indiaAahuti Prajapati
The document provides information on various types of furniture, materials used, and their applications. It discusses the different uses of furniture in residential, commercial, street, and hospital settings. It also details the main raw materials used like plywood, wood, laminates, and their specifications. Common finishes applied to furniture like laminates, veneers, and hardware items are also outlined. Specific types of street furniture and hospital furniture are described along with the materials typically used for them.
The document discusses various types of wall treatments and finishes that can be used for interior and exterior walls. Some of the most common wall treatments mentioned include paint, wallpaper, paneling, mirrors, fabrics, and carpeting. Specific wall finishes discussed include plaster, gypsum wallboard, tile, wood, stone, brick, glass, vinyl wall covering, and resin. The document provides details on the application and characteristics of different wall treatment and finishing materials.
This document provides information on the dry installation method for natural stone cladding. It discusses:
- The dry installation method uses embedded metal anchors and ties to connect the stone to the wall without mortar. Thicker stone is required as it involves drilling.
- Advantages include the stone installation being safe and durable, allowing for expansion/contraction, and creating a thermal barrier between the stone and wall.
- The installation process involves selecting appropriate bracket materials, preparing the wall surface, and then drilling holes and inserting brackets/pins to securely attach each stone to the wall with a small gap between stones.
- Proper material selection and accurate installation are important to avoid cracks and ensure the stone cladding
This document provides information on vernacular architecture in hot and dry climate regions, with a focus on Bikaner, Rajasthan, India and Iran. It describes the climatic conditions of hot and dry regions, with maximum temperatures of 40-50°C. It then discusses specific architectural features used in Bikaner, such as the Jalwali house layout with inner courtyards, guest rooms, and unique mud grain storage jars. Finally, it covers passive cooling techniques used in Iranian architecture, such as courtyards, basements, wind catchers, and building orientation, which helped maintain thermal comfort before modern technologies.
The document provides an overview of different styles of interior design including modern, contemporary, minimalist, industrial, mid-century modern, Scandinavian, traditional, transitional, French country, and bohemian. For each style, the summary discusses characteristic design elements, color palettes, furniture, and materials commonly used in that style. The document also covers the history of interior design from ancient civilizations like Mesopotamia and Egypt to modern applications of different styles.
anant raje, architect, indian architect, design, philosophy, concept, works, projects, educational purpose, buildings, pictures, iifm, bda, louis i kahn of india, life, carrer, death, photos
2. The document outlines various factors that influence human thermal comfort, including physical conditions like temperature, humidity, air movement, and radiant sources, as well as physiological conditions like sex, age, health, and activity level. It provides recommendations for
This document provides an introduction to interior design. It defines interior design as "the art or process of designing the interior decoration of a room or building." An interior designer coordinates and manages interior design projects. The document outlines several principles of interior design including scale, proportion, balance, rhythm, emphasis, and harmony. It also discusses various elements of interior design such as space, shape, form, mass, line, texture, pattern, light, and color. Interior design is important for enhancing functionality, aesthetics, and reflecting lifestyle.
Item vi.a. doyle street mews pc 09 28-2017E'ville Eye
This document provides information about bike parking and unit areas for a 6-unit residential development. It states that there will be 8 indoor bike racks for units 1, 2, 4, and 5, and 2 indoor bike racks for units 3 and 6, along with 4 outdoor guest bike racks for a total of 14 bike racks on site. The total floor area for the 6 units is 9,964 square feet. Each unit is described as having either 3 bedrooms and 3.5 bathrooms with a bonus room, or 3 bedrooms and 2.5 bathrooms with a bonus room. An open space area tabulation is also provided showing the private and common open space areas.
This document contains 29 notes pertaining to the reconstruction of Holly Hill Drive. It specifies that construction standards will be in accordance with the City of Greenville and ODOT specifications. It identifies utility owners within the project limits and notes the contractor's responsibility to coordinate with utility companies. The notes provide details on items of work including excavation, subgrade preparation, seeding and mulching, record keeping, and safety requirements.
The document discusses the key elements of interior design: line, space, shape, form, texture, and color. It provides examples and definitions for each element. Line can be used to create movement, harmony, and set form and shape. Space can be positive (filled) or negative (empty). Shape is defined by its dimensions while form includes depth. Texture can be tactile or visual. Color is influenced by hue, value, and intensity and can be organized by primary, secondary, tertiary, complementary, or monochromatic schemes.
The document discusses different types of wall panelling materials and their uses. It describes various panelling materials like wood, metal, acoustic and structural panels. Wood panelling provides insulation and decorative appearance. Panelling is used to cover walls for aesthetic purposes and can provide insulation, soundproofing and reduce construction costs. Common panelling materials mentioned include wood, metal, laminate and tileboard panels.
This document contains definitions and explanations of various climatic and meteorological concepts. It discusses factors that determine climate like temperature, precipitation, altitude, latitude, winds and more. It also defines terms like weather, humidity, wind, atmospheric pressure and how they impact human thermal comfort and building design. Key climatic classifications and methods to assess human comfort like effective temperature and clothing insulation are also summarized.
Metal Cladding has provided coating applications to industries since 1943. The document discusses different types of cladding materials like wood, concrete, stone, and metals. It focuses on metal cladding, noting that metals provide strong and durable protection for buildings while also allowing for aesthetic versatility. Specific metals discussed include aluminum, steel, and copper, outlining their common uses, benefits, and drawbacks for cladding.
Laurie Baker was a British architect who came to India in 1945 as a missionary. He lived and worked in India for over 50 years, obtaining Indian citizenship in 1989. Baker is renowned for his initiatives in low-cost housing and sustainable architecture using locally available materials. Some key aspects of his work included using cost-effective materials like brick, laterite, mud and cow dung in innovative construction techniques like rat trap bond. He designed over 1000 residences and 40 other buildings in Kerala emphasizing natural ventilation, privacy and historical influences. Baker received the Padma Shri award in 1990 for his contributions to architecture.
The document discusses interior space and how it is defined and structured. Architectural elements like columns, walls, floors and roofs are used to articulate and delineate space. Structural systems like linear, planar and volumetric approaches influence the dimensions and arrangement of interior spaces. Interior design elements like partitions, ceilings, furniture, lighting and finishes are also used to further define spaces and influence spatial qualities within the overall architectural framework.
Interior architecture is the process of designing the interior spaces of buildings, taking into account how people will use and interact with the structural spaces. An interior designer's responsibilities include meeting with clients to understand their needs and budget, developing design concepts, creating drawings and finding furnishings. There are several types of interior design specializations including residential, commercial, hospitality, healthcare, universal and exhibition design. To be an interior designer requires creativity, practical and project management skills, as well as the ability to communicate effectively and find solutions within clients' budgets.
Interior design is the process of shaping the experience of interior space, through the manipulation of spatial volume as well as surface treatment for the betterment of human functionality.
The Bidani House project demonstrates how to design a climate-responsive building on a constrained urban site. Located in Faridabad's composite climate zone, the house has large temperature swings throughout the year. Key sustainable features include developing the house form around a central courtyard to act as a heat sink, using buffer spaces on the overheated southwestern exposure, allowing solar penetration according to seasonal changes through the building form, and using local stone for thermal mass to moderate temperature swings. The project shows how responsive design is possible even on a fixed small urban site.
furniture use , materials , market survey in indiaAahuti Prajapati
The document provides information on various types of furniture, materials used, and their applications. It discusses the different uses of furniture in residential, commercial, street, and hospital settings. It also details the main raw materials used like plywood, wood, laminates, and their specifications. Common finishes applied to furniture like laminates, veneers, and hardware items are also outlined. Specific types of street furniture and hospital furniture are described along with the materials typically used for them.
The document discusses various types of wall treatments and finishes that can be used for interior and exterior walls. Some of the most common wall treatments mentioned include paint, wallpaper, paneling, mirrors, fabrics, and carpeting. Specific wall finishes discussed include plaster, gypsum wallboard, tile, wood, stone, brick, glass, vinyl wall covering, and resin. The document provides details on the application and characteristics of different wall treatment and finishing materials.
This document provides information on the dry installation method for natural stone cladding. It discusses:
- The dry installation method uses embedded metal anchors and ties to connect the stone to the wall without mortar. Thicker stone is required as it involves drilling.
- Advantages include the stone installation being safe and durable, allowing for expansion/contraction, and creating a thermal barrier between the stone and wall.
- The installation process involves selecting appropriate bracket materials, preparing the wall surface, and then drilling holes and inserting brackets/pins to securely attach each stone to the wall with a small gap between stones.
- Proper material selection and accurate installation are important to avoid cracks and ensure the stone cladding
This document provides information on vernacular architecture in hot and dry climate regions, with a focus on Bikaner, Rajasthan, India and Iran. It describes the climatic conditions of hot and dry regions, with maximum temperatures of 40-50°C. It then discusses specific architectural features used in Bikaner, such as the Jalwali house layout with inner courtyards, guest rooms, and unique mud grain storage jars. Finally, it covers passive cooling techniques used in Iranian architecture, such as courtyards, basements, wind catchers, and building orientation, which helped maintain thermal comfort before modern technologies.
The document provides an overview of different styles of interior design including modern, contemporary, minimalist, industrial, mid-century modern, Scandinavian, traditional, transitional, French country, and bohemian. For each style, the summary discusses characteristic design elements, color palettes, furniture, and materials commonly used in that style. The document also covers the history of interior design from ancient civilizations like Mesopotamia and Egypt to modern applications of different styles.
anant raje, architect, indian architect, design, philosophy, concept, works, projects, educational purpose, buildings, pictures, iifm, bda, louis i kahn of india, life, carrer, death, photos
2. The document outlines various factors that influence human thermal comfort, including physical conditions like temperature, humidity, air movement, and radiant sources, as well as physiological conditions like sex, age, health, and activity level. It provides recommendations for
This document provides an introduction to interior design. It defines interior design as "the art or process of designing the interior decoration of a room or building." An interior designer coordinates and manages interior design projects. The document outlines several principles of interior design including scale, proportion, balance, rhythm, emphasis, and harmony. It also discusses various elements of interior design such as space, shape, form, mass, line, texture, pattern, light, and color. Interior design is important for enhancing functionality, aesthetics, and reflecting lifestyle.
Item vi.a. doyle street mews pc 09 28-2017E'ville Eye
This document provides information about bike parking and unit areas for a 6-unit residential development. It states that there will be 8 indoor bike racks for units 1, 2, 4, and 5, and 2 indoor bike racks for units 3 and 6, along with 4 outdoor guest bike racks for a total of 14 bike racks on site. The total floor area for the 6 units is 9,964 square feet. Each unit is described as having either 3 bedrooms and 3.5 bathrooms with a bonus room, or 3 bedrooms and 2.5 bathrooms with a bonus room. An open space area tabulation is also provided showing the private and common open space areas.
This document contains 29 notes pertaining to the reconstruction of Holly Hill Drive. It specifies that construction standards will be in accordance with the City of Greenville and ODOT specifications. It identifies utility owners within the project limits and notes the contractor's responsibility to coordinate with utility companies. The notes provide details on items of work including excavation, subgrade preparation, seeding and mulching, record keeping, and safety requirements.
This document contains an index of drawings for a commercial project. The index includes 14 drawings with titles like "Third Floor Plan", "Cover Sheet/General Notes", and "Details - Partition". It also contains sections for abbreviations, general notes, a door hardware schedule, and a parts list and assembly drawing for an angle support. The document provides an overview of the drawings included in a commercial building project set through an index and additional reference materials.
CE 444 Contracts and SpecificationsAssignment 7 - Conduct a 95MaximaSheffield592
This document provides the scope of work for repairs to sill plates on nine road closure structures in East Grand Forks, Minnesota. Key details include:
- Repairs must fill voids under existing sill plates and replace sections of steel sill plates with concrete.
- Submittals such as a work plan, safety plan, repair plan, and traffic control plan are required before starting work.
- Concrete mix design must achieve a minimum strength of 5,000 psi and water-cement ratio of no more than 0.40.
- Work must be completed by December 1 for some repairs and June 1 for others.
- Traffic control is needed to allow one lane to remain open when working on busy
The document discusses various aspects of the tendering process for construction projects, including:
1) Different types of tenders such as open, sealed, single, limited, and negotiated tenders.
2) Key documents involved in the tendering process such as the tender notice, tender form, and various envelopes used for submitting tenders.
3) Important considerations when evaluating tenders such as checking rates, scrutiny of documents, and preparation of a comparative statement to select the lowest bidder.
This document is a construction contract between Al Noor Consultants and Zulifiqar Ahmed Architectural and Engineering Private Limited for the construction of a residential development project in Lahore, Pakistan. Key details include:
- The contractor will complete construction of 150 plots of land with houses, a mosque, school, park and infrastructure over 4 years.
- As a security, the client will sign over ownership of 8 plots to the contractor initially valued at Rs. 1200 per square foot for structures and Rs. 1000 per square foot for finishes.
- The contractor must complete the project by June 2021. Liquidated damages of 0.5% per day will be charged for delays beyond this date, up to
This document provides removal plans for a basement, first floor, and second floor of a residence. It includes a legend describing items to be removed from each floor, such as walls, floors, fixtures, casework, and more. General notes cover safety, permitting, coordination, protection of existing areas, and other requirements for the demolition work.
The document provides general construction notes for a proposed single family residence project. It includes 21 notes that specify requirements for code compliance, construction methods and materials, responsibility of contractors, addressing, grading plans, soils reports, and other general project requirements. The notes establish standards and provide guidance for all drawings and the work of contractors involved in the construction project.
This document provides general construction notes for a proposed single family residence project. It includes 20 notes that specify requirements and responsibilities related to building codes, construction methods, materials, inspections, and other project details. The notes reference various California building codes and clarify that more specific/detailed information takes precedence over general notes. They assign responsibilities to the contractor and subcontractors to construct the project according to approved plans and notify the architect of any issues or discrepancies.
Boq of khadeja storage tank, well, and booster pumping stationHarish Mahavar
This document outlines the bill of quantities for a construction project to build a water storage tank, well, and booster pumping station in Beit Hanoun, Gaza. It includes 7 sections for different components of the work: (A) water tank, (B) booster station, (C) well, (D) piping yard, (E) service building, (F) electrical works, and (G) miscellaneous works. It specifies that unit prices will be in US dollars and cover all costs to complete the work, including materials, labor, equipment, insurance, and permits. It also requires installation of a remote monitoring and control system to allow SMS and email reporting on the status of the well.
This document contains architectural drawings for a commercial project at the Art Institute of Houston including floor plans, furniture plans, power plans, reflected ceiling plans, exterior elevations, building sections, and enlarged bathroom plans and elevations. The drawings include room labels, door schedules, notes, and other details. Revision numbers and indexes are provided for the various drawings.
This construction contract is between Montrose County and a contractor for a construction project. The contractor will complete all work specified in the scope of work and RFP attachments by the completion date. The owner will pay the contractor $_________ for satisfactory work, retaining 10% of each payment until final payment. The contract documents include the construction contract, plans, specifications, permits, bonds and other documents defining the project and terms of payment.
This document defines key terms related to construction contracts and documents. It discusses authorship and licensing of the document. It also outlines what constitutes contract documents such as agreements, specifications, drawings, and defines roles like owner, architect, engineer, contractor, and subcontractor. It addresses the intent and conformity of contract documents, supplementary drawings and instructions, and responsibilities around shop drawings. Finally, it covers laws and regulations pertaining to the project site, required permits and taxes, and establishing reference marks.
This construction contract is between Montrose County, Colorado and a contractor for a construction project. The contractor will complete all work specified in the scope of work and RFP documents. The work must be completed by a specified date. The county will pay the contractor $________ for satisfactory completion of the work. The contract documents define the roles and responsibilities of the contractor and county, including requirements for bonds, payments, disputes, safety, and indemnification.
Construction claims, disputes and project closuresrinivas2036
This document discusses construction claims, disputes, and project closure. It begins by explaining that during project execution, issues often arise between parties that cannot be resolved, resulting in claims from contractors for time extensions or cost reimbursements. These claims can be settled amicably or become disputes if the owner does not agree. Common sources of claims include defects in contracts, site conditions differing from descriptions, scope changes, and payment delays. The document provides guidance on claim management, notification, substantiation, and resolution procedures. It also discusses mechanisms for dispute avoidance and resolution such as negotiation, mediation, arbitration, and their advantages over legal proceedings.
'DRISHTI' Chapter 16: Checklist for Contract Document (कॉन्ट्रैक्ट डॉक्युमेंट...Vipin Bakiwala
It provides a detailed contract document to be referred by the contractor before starting the construction. It mentions the duties, rights, liabilities, and responsibilities of a contractor before, during and after the construction as well as some other important points.
This document outlines an assignment for a practical scenario involving the construction of a district cooling plant project in the UAE. It provides context for the project, including details about the employer, main contractor, type of contract used, and scope of work. It then lists the requirements for the assignment, including describing the basis for contract selection, aspects of design liability, risk apportionment, potential unforeseen problems, and dispute resolution techniques. Guidance is provided on referencing legal principles and contract clauses. The maximum length for the response is 2,000 words.
The document provides instructions to tenderers for a construction project. It outlines 15 sections related to the scope of work, general conditions and specifications, soils reports, substitutions, a mandatory tender information meeting, addenda, prequalification requirements, tender confidentiality, tender deposits and performance guarantees, government taxes, withdrawal procedures, validity of tenders, acceptance of the tender and contract execution, the owner's rights, contract award criteria, workplace safety insurance board requirements, and accessibility standards. Tenderers must follow all instructions and meet prequalification requirements to be considered for the contract.
Episode 28 : Project Management Contract
Typical services of the employer are:
Obtaining official approvals
Commissioning experts
Provision of the documents required for planning, such as site plan, data on soil conditions etc.
Supply of utilities for commissioning
Free of charge provision of areas for site facilities
Free of charge supply of power and water to the building site.
Similar to Final Docket For VH ,AT Kolhapur India (20)
3. THE EXISTING CONDITIONS IN THE CONSTRUCTION DOCUMENTS ARE BASED ON THE SURVEY DRAWINGS
DATED: 18/09/12
ANY DISCREPANCIES BETWEEN THE (E) CONDITIONS DOCUMENTS AND THE ACTUAL FIELD DOCUMENTS SHALL
BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE BEFORE PROCEEDING WITH ANY WORK.
THE CONTRACTOR SHALL BE FAMILIAR WITH ALL LANDLORD REQUIREMENTS AND SHALL BE RESPONSIBLE FOR
COMPLIANCE WITH SAME. THE CONTRACTOR SHALL INVESTIGATE LOCAL CODES AND PROCEDURES AND SHALL
COMPLY WITH ALL REQUIREMENTS.
THE CONTRACTOR SHALL CONTACT LANDLORD REPRESENTATIVE BEFORE CONSTRUCTION COMMENCES.
ALL CONDUIT, EQUIPMENT AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST SAFETY RULES AND
REGULATIONS OF ALL AUTHORITIES AND AGENCIES HAVING JURISDICTION.
THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIRE PROTECTION
DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES.
PROVIDE ADDITIONAL EXIT SIGNS AND FIRE EXTINGUISHERS IN TYPE, NUMBER AND LOCATIONS AS DIRECTED.
EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETION OF
HIS WORK ON A DAILY BASIS. AREA OF WORK TO BE DUSTED, SWEPT AND MOPPED TO SAME CONDITION AS START OF
WORK. ALL WASTE, RUBBISH AND EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL TRASH, INCLUDING TRASH GENERATED
FROM OWNER FURNISHED ITEMS AND BY OWNER'S CONTRACTORS FOR THE DURATION OF THE PROJECT.
REMOVE ALL ABANDONED IMPROVEMENTS, INCLUDING ELECTRICAL AND MECHANICAL.
ALL EXISTING WORK NOT IN THIS SCOPE OF WORK SHALL BE MAINTAINED IN ITS ORIGINAL CONDITION.
G.C. SHALL BE RESPONSIBLE FOR COORDINATION WITH OWNER'S REPRESENTATIVE TO PROVIDE A TIMELY ARRIVAL OF
ALL MATERIALS, EQUIPMENT AND OTHER SUCH ITEMS TO BE UTILIZED ON THIS PROJECT (OWNER-PROVIDED OR
OTHERWISE). G.C. SHALL NOTIFY OWNER'S REPRESENTATIVE IN WRITING WITHIN 5 DAYS OF DATE OF APPROVED WORK
AUTHORIZATION OF THOSE ITEMS THAT MAY NOT BE READILY AVAILABLE. IF NOTIFICATION IS NOT PROVIDED TO THE
OWNER'S REPRESENTATIVE, THE G.C. ACCEPTS RESPONSIBILITY FOR THE PROPER ORDERING AND FOLLOW-UP OF
SPECIFIED ITEMS AND WILL PURSUE WHATEVER MEANS NECESSARY AT NO ADDITIONAL COST TO OWNER.
WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT IN
CONTRACT, HE SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS.
CONTRACTOR TO ENSURE AVAILABILITY OF ALL SPECIFIED ITEMS SO AS NOT TO CREATE A HARDSHIP TO THE OWNER
AND NOT DELAY PROGRESS OF THE WORK. NO EXTENSION OF TIME SHALL BE PERMITTED.
CONTRACTOR SHALL BE RESPONSIBLE TO RECEIVE, INVENTORY, STORE AND SECURE ANY OWNER FURNISHED ITEMS(OFI)
SUPPLIED AND DELIVERED TO THE JOBSITE, OR OTHER AGREED UPON LOCATION, AND FORWARD THE RECEIVING
DOCUMENT(S) TO THE OWNER'S REPRESENTATIVE - SEE PRE-BID LETTER FOR DETAILS REGARDING OWNER-FURNISHED
ITEMS.
NO SUBSTITUTIONS OF ANY MATERIALS OR ITEMS SPECIFIED IN THE DOCUMENTS ARE PERMITTED,
MATERIALS
REGULATIONS
1.
JOB SITE OPERATIONS
2 .
3.
4.
5.
1.
2.
3.
1.
2.
3.
4.
SHOULD A CONFLICT EXIST BETWEEN THE CONSTRUCTION DOCUMENTS AND/OR THE SPECIFICATIONS THE OWNER'S
REPRESENTATIVE SHALL BE INFORMED OF THIS DISCREPANCY IMMEDIATELY, AT WHICH TIME OWNER'S REPRESENTATIVE
SHALL PROVIDE DIRECTION AS TO HOW TO PROCEED.
INSPECT SITE AND VERIFY FIELD DIMENSIONS BEFORE COMMENCING WITH CONSTRUCTION. NOTIFY OWNER'S
REPRESENTATIVE AND LANDLORD IMMEDIATELY IF THERE ARE ANY SIGNIFICANT DISCREPANCIES.
GENERAL CONTRACTOR SHALL COORDINATE WORK PERFORMED BY OTHER CONTRACTORS. ANY DISCREPANCIES
SHALL BE BROUGHT TO THE OWNER'S REPRESENTATIVE'S ATTENTION BEFORE PROCEEDING WITH WORK.
ALL CONTRACTORS, SUBCONTRACTORS, VENDORS AND MATERIAL SUPPLIERS SHALL BE RESPONSIBLE FOR REVIEWING
THE COMPLETE SET OF DOCUMENTS AS SHOWN IN THE SHEET INDEX. FAILURE TO REVIEW CONSTRUCTION DOCUMENTS
WILL NOT RELIEVE ANY CONTRACTORS, SUB-CONTRACTORS, VENDORS OR MATERIAL SUPPLIERS FROM PERFORMING
WORK OR PROVIDING MATERIALS REQUIRED FOR THE COMPLETION OF THIS PROJECT AS DEFINED WITHIN WITHIN THE
DOCUMENTS AT TIME OF BID.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS.
ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS AND NUMBER OF
ITEMS PROVIDED. UPON DISCOVERY OF DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING
DRAWINGS, OWNER'S REPRESENTATIVE SHALL BE IMMEDIATELY NOTIFIED IN WRITING.
1.
2.
3.
4.
5.
6.
ABV : ABOVE
AFFL : ABOVE FLOOR FINISH LEVEL
AL. : ALUMINUM
CL : CENTER LINE
CLG : CEILING
CM : CONSTRUCTION MANAGER
COL : COLUMN
CONC : CONCRETE
CONSTR : CONSTRUCTION
CONT : CONTINUOUS
C/C : CENTER TO CENTER
DIA : DIAMETER
DWG : DRAWING
ELEV : ELEVATION
EQ : EQUAL
(E) : EXISTING
EXT : EXTERIOR
FLR : FLOOR
GC : GENERAL CONTRACTOR
GYP. BD : GYPSUM BOARD
HVAC : HEATING VENTILATION AIR CONDITIONING
L.L : LEASE LINE
MAX : MAXIMUM
MS : MILD STEEL
NTS : NOT TO SCALE
PLMB : PRELAMINATED BOARD
PM : PROJECT MANAGER
(REF) : REFERENCE
SFT : SQUARE FEET
SS : STAINLESS STEEL
THK : THICK
TYP : TYPICAL
UON : UNLESS OTHERWISE NOTED
VIF : VERIFY IN FIELD
FFL : FINISH FLOOR LEVEL
DESIGN FORUM
#32, 1ST FLOOR, 5TH MAIN,
JAYAMAHAL EXTENSION,
BANGLORE - 560046
TEL: 080 - 42048380
+91 9945235382
E-MAIL : divya@designforum.in
ARCHITECT:
MADHURA FASHION & LIFESTYLE
REGENT GATEWAY NO.5B,
DOODDENAKUNDI KIADB,
INDUSTRIAL AREA, ITPL ROAD,
BANGALORE : 560048
KARNATAKA, INDIA
SITE ADDRESS :
KOLHAPUR
COMPANY NAME :
BRAND :
VAN HEUSEN
GENERAL CONTRACTORS :
NATHULAL
M +91-9881373170
ASSOCIATED ENGINEERS GROUP
CONSULTING & DESIGN ENGINEERS
ELECTRICAL, MECHANICAL & IT
SYSTEMS BOMMANAHALLI,
BANGALORE-560 068, INDIA
T +91-80-2573 3786 F +91-80-2573 3786
M +91-98 4513 9077
E-MAIL: ghouseaeg@yahoo.com
MEP CONSULTANT :
DIMENSIONS SHOWN ON PLANS ARE TO FACE OF EXTERIOR MASONRY, CONCRETE COLUMNS OR GRID LINES AND FACE
OF STUD UNLESS OTHERWISE NOTED OR DETAILED.
THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS, VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND CONFIRM
WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC. SHALL BE IMMEDIATELY REPORTED TO THE
ARCHITECT / OWNER'S REPRESENTATIVE FOR CLARIFICATION PRIOR TO PERFORMANCE OF ANY WORK IN QUESTION.
COLUMN CENTER LINE (OR GRID LINES) ARE SHOWN FOR DIMENSIONS. VERIFY EXACT LOCATIONS IN FIELD.
A COPY OF CLIENT-APPROVED CONSTRUCTION DOCUMENTS MUST BE ON SITE DURING CONSTRUCTION.
OWNER'S REPRESENTATIVE AND TENANT ARE THE SAME FOR PURPOSES OF THESE DRAWINGS.
IF ANY ERRORS OR OMISSIONS APPEAR IN CONTRACT DOCUMENTS CONTRACTOR SHALL NOTIFY OWNER'S
REPRESENTATIVE IN WRITING OF SUCH ERRORS OR OMISSIONS.
7.
8.
9.
10.
11.
12.
CLIENT : NOTE :
01.THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED OR HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE, OTHER
THAN FOR WHICH IT IS HANDED.
02.ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03.WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04.ANY CHANGE REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05.THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06.IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFEREED TO THE ARCHITECT.
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES, THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
CAUTION :
SCALE : NTS
DATE : 22/10/2012
DRN.BY : DIVYA
APPD.BY : KARAAN MEHRRA
LOCATION :
KOLHAPUR
GENERAL NOTES
COVER SHEET01
ABBREVIATIONS :
02 PROJECT TEAM :
04
LEGEND :
03
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION SIGN OFF BY CLIENT:
4. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
M.RAFEEQ
18.09.2012
SURVEY PLAN
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
N
KOLHAPUR
NOTES :
1140580330
4500
905
B B'
A'
A
26031502603985260
124014904053270
82041516402603270
26028752603270
100
1060260
500
100100
6107255701250
95
250250250
GROUND FLOOR PLAN
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
B.O.S AT 3200 MM
FROM UFFL
EXISTING WOODEN PARTITION
EXISTING WINDOW
B'B
A
EXISTING BEAM DROP DOWN
AT 2830 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2760 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2760 MM FROM UFFL
PROPOSED STAIRCASE AREA
EXISTING COMMON STAIRCASE
EXISTING BEAM DROP DOWN
AT 2830 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2830 MM FROM UFFL
UPDOWN
50
1120 1480 1750 270 1775
220
890 260
2603150
31754153865260945
1130 3270 270 1645 415 580 245
25
270
135
19401935260
150
945
110
3420 410 1490 405 850 260
2602310865270
75
3200725270945
1180
260
260
260935
70
920
FIRST FLOOR PLAN
A'
5. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
M.RAFEEQ
18.09.2012
SECTIONAL ELAEVATION
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
KOLHAPUR
NOTES :
EXISTING BEAM DROP DOWN
AT 2830 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2760 MM FROM UFFL
150
3001930900
EXISTING BEAM DROP
DOWN AT 2775 MM
FROM UFFL
B.O.S AT 3200 MM
FROM UFFL
150
4252775
190
170
170
190
EXISTING ROLLING
SHUTTER
B.O.S AT 3130 MM
FROM UFFL
SECTION AA'
EXISTING BEAM DROP
DOWN AT 2830 MM
FROM UFFL
EXISTINGWINDOW
150
30091011801040
900
SECTION BB'
EXISTING BEAM DROP
DOWN AT 2775 MM
FROM UFFL
B.O.S AT 3200 MM
FROM UFFL
B.O.S AT 3130 MM
FROM UFFL
EXISTING WOODEN
PARTITION
150
4252775
150
6. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
CIVIL LAYOUT
FIRST FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 01
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
KOLHAPUR
NOTES :
LEGEND
WALL TO BE BUILT
WINDOW TO BE
CLOSED
WALL TO
BE BUILT
235
11002000
250250
1100
2000
11002000
1095
21203440
3080
1125
150
100
750 320
19403140
1020
150
1480
WALL TO
BE BUILT
7. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
CIVIL LAYOUT
GROUND FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 01
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
KOLHAPUR
NOTES :
LEGEND
WALL TO BE BUILT
WINDOW TO BE
CLOSED
235
11002000
250250
1100
2000
11002000
1095
2070 1200 1895 1500
7793420
3070
8. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
FURNITURE LAYOUT
FIRST FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 02
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
KOLHAPUR
NOTES :
9. ELEVATION-1
SPORTS12FT
CASH BACK
Touchscreen
Mouse
CASH
Touchscreen
Mouse
ELEVATION-5
VDOT4FT
PROPOSED
STAIRCASE
ELEVATION-2
KNITS8FT
ELEVATION-3
VDOT 4FT
ELEVATION-6
VDOT 4FT
TRIAL ROOM 1
KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
FURNITURE LAYOUT
GROUND FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 02
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
KOLHAPUR
NOTES :
10. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
MARKING LAYOUT
FIRST FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
02DRAWING NO : 03
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
KOLHAPUR
NOTES :
850405
60
760
60
610410
18060
500
500
606060
739775
1020
15060 60
415
60
500
500
60
1870
60
8763105651964
75
900
1476
1162
824 1106
2834
1247
1881
1014
1000
100
750 280
1061
1055
100
750
1125
MIRROR
11. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
25.10.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 11
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
N
KOLHAPUR
NOTES :
DESCRIPTIONIMAGE
RLT SOLOR RECESSED WALL WASHER/
RLT CDHMFG RECESSED DOWNLIGHT
CFL 2X26W
RLT DIVA 70 W CDMT TRACK LIGHT
ONKYO CEILING MOUNTED SPEAKER
2MTR. POWER TRACK
RLT LFL 28W 600MM FLUORESCENT
TUBE
RLT LFL 28W 1200MM FLUORESCENT
TUBE
SP
1 MTR. POWER TRACK
LIGHTING LEGEND
LIGHTING LAYOUT WITH
AC CASSETTE
FIRST FLOOR
1349
UPDOWN
ELEVATION-7
SUITS 8FT
ELEVATION-9
SHOES6FT
TOILET
TRIAL
ROOM 2
DN
ELEVATION-8
SUITS 6FT
EXISTING
OPENING
TO BE
CLOSED
MIRROR
ELEVATION-11
CEREMONY 8FT
ELEVATION-12
WORLDWEAR8FTELEVATION-13
FORMALS8FT
MIRROR
ELEVATION-10
ACC WALL 8FT
BACK ROOM
1250 900 900 900 900 900
800450750900900600696
900 900 1200 600 900 685310
1250
1250
1250 1200 1200 900 675
675
750 1200 1200 1200 900 675
900 6751250 1200 1200 1200
1262
1200
12509009009009008967001250
1250
1250
1250
1195900900371
760
1200 635 800
1250
1500
8965193069009001899
750
760
760
999
531531
490565
563
510510
563
500 900
356383
383361
SP
SP
SP
549 549
SP
430 448
332
649
462 462
849
SP
SP
1649
499729
900885
900
849
1950
900900
NO FALSE CEILING
CEILING HEIGHT : 2610 MM
ACRYLIC EMLUSION DULUX
MAKE(CHARCOAL SLATE 30BB 21/014)
2 TR
2 TR
2 TR1415
2095
1415
1415
1855
525
465
12. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
25.10.2012
LIGHTING LAYOUT WITH
AC CASSETTE
GROUND FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 11
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
N
KOLHAPUR
NOTES :
DESCRIPTIONIMAGE
RLT SOLOR RECESSED WALL WASHER/
RLT CDHMFG RECESSED DOWNLIGHT
CFL 2X26W
RLT DIVA 70 W CDMT TRACK LIGHT
ONKYO CEILING MOUNTED SPEAKER
QTY.
2MTR. POWER TRACK
RLT LFL 28W 600MM FLUORESCENT
TUBE
RLT LFL 28W 1200MM FLUORESCENT
TUBE
SP
1 MTR. POWER TRACK
16
27
00
00
20
04
08
LIGHTING LEGEND
ELEVATION-1
SPORTS12FT
CASH BACK
Touchscreen
Mouse
CASH
Touchscreen
Mouse
ELEVATION-4
VDOT 8FT
PROPOSED
STAIRCASE
ELEVATION-2
KNITS8FT
ELEVATION-3
VDOT 4FT
ELEVATION-5
VDOT4FT
ELEVATION-6
VDOT 4FT
TRIAL
ROOM 1
1250 825
9009009009009007611250
9009009007618999031248
596900
191
1250 1200 1200
220
886
898
1250 1200 1200
900596
1250 1200 820
1250 1160 1200
1250 1160 1200 1400 1555
1250 1160 1200 1200 1200
1250
1250
1250
8451250
1250845
1250
900
1250
983
562562
600600
SP
SP
SP
SP
SP
549549
849
549549
849
260 465
549 549
CEILING HEIGHT : 2625MM
ACRYLIC EMLUSION DULUX
MAKE(CHARCOAL SLATE 30BB 21/014)
850 705
ENTRANCE
VISUAL MERCHANDISING
AREA
UP
3 TR
2 TR
1560
1950
1110
1745
200
23
2000 1720 1000 422
13. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
MARKING LAYOUT
GROUND FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 03
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
ELEVATION-1
SPORTS12FT
CASH BACK
Touchscreen
Mouse
CASH
Touchscreen
Mouse
ELEVATION-5
VDOT4FT
PROPOSED
STAIRCASE
ELEVATION-2
KNITS8FT
ELEVATION-3
VDOT 4FT
ELEVATION-6
VDOT 4FT
TRIAL ROOM 1
3670
60
1250
43
1250 499
858
KOLHAPUR
NOTES :
14. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
NIZAM
25.10.2012
FLOORING LAYOUT
GROUND FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 04
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
600
600
600 MM X 600 MM BIRLO IVORY
VITRIFIED TILE OF NITCO MAKE
LEGEND
300 MM X 300 MM CERAMIC TILE
CARPET AS APPROVED
LOCATION :
KOLHAPUR
PAPER JOINT
600 MM (L) X 600 MM
(W) VITRIFIED TILE
FLOORING 1 : 2 : 4 (1 CEMENT : 2 COARSE SAND : 4 GRADED
STONE AGGREGATE), FINISHED WITH A FLOATING COAT OF NEAT
CEMENT INCLUDING CEMENT SLURRY. FLOORING TO BE 40MM
THICK WITH 20MM NOMINAL SIZE STONE AGGREGATE.
EXISTING FLOORING
FLOORING DETAIL
15. UPDOWN
TOILET
TRIAL
ROOM 2
DN
PROPOSED
STAIRCASE
EXISTING
OPENING
TO BE
CLOSED
850405
60
760
60
610410
18060
2470
60
650
500
60
2470
6060
2472
60
739775500
1020
150
60
2470
60
415
60
1870
60
500
500
60
1870
60
8763105651500964
75
PAPER JOINT
600 MM (L) X 600 MM
(W) VITRIFIED TILE
FLOORING 1 : 2 : 4 (1 CEMENT : 2 COARSE SAND : 4 GRADED
STONE AGGREGATE), FINISHED WITH A FLOATING COAT OF NEAT
CEMENT INCLUDING CEMENT SLURRY. FLOORING TO BE 40MM
THICK WITH 20MM NOMINAL SIZE STONE AGGREGATE.
EXISTING FLOORING
FLOORING DETAIL
KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
NIZAM
25.10.2012
FLOORING LAYOUT
FIRST FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 04
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
600 MM X 600 MM BIRLO IVORY
VITRIFIED TILE OF NITCO MAKE
LEGEND
300 MM X 300 MM CERAMIC TILE
CARPET AS APPROVED
LOCATION :
KOLHAPUR
16. 01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
PARTITION LAYOUT
FIRST FLOOR
DRAWING NO : 05
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
567 SQF.
622 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
LOCATION :
KOLHAPUR
PARTITION LEGEND
75 MM THK. PARTITION WITH 50 MM X 50 MM
HARDWOOD FRAMEWORK AT 600 MM C/C
SPACING WITH 12 MM PLY ON BOTH SIDES.
60 MM WIDE BAND AND 500 MM WIDTH PORTALS MADE IN
TWO LAYERS OF 19 MM THK. COMMERCIAL PLY COVERED
WITH 10 MM THK. MDF ON BOTH SIDES AND FINISHED WITH
SUPER GLOSSY BLACK/WHITE LAMINATE FINISH
PORTAL DETAIL
500
60
40 MM SQUARE WOODEN BATTEN WITH
10 MM MDF BOARD ON THREE SIDES AS
VERTICAL FRAME FOR PORTAL TO BE
FINISHED WITH APPROVED SUPER
GLOSSY LAMINATE
P1
60 MM WIDE BAND AND 500 MM WIDTH PORTALS MADE IN TWO
LAYERS OF 19 MM THK. COMMERCIAL PLY COVERED WITH 10
MM THK. MDF ON BOTH SIDES AND FINISHED WITH
401 SUPER GLOSSY BLACK LAMINATE
75 MM THK. PARTITION WITH 50 MM X 50 MM HARDWOOD
FRAMEWORK AT 600 MM C/C SPACING WITH 12 MM PLY ON
BOTH SIDES.
60 MM WIDE BAND AND 500 MM WIDTH PORTALS MADE IN
TWO LAYERS OF 19 MM THK. COMMERCIAL PLY COVERED
WITH 10 MM THK. MDF ON BOTH SIDES AND FINISHED WITH
107 SUPER GLOSSY WHITE LAMINATE
19 MM THK. COMMERCIAL PLY BACKING
P2
P3
P4
KARAAN R MEHRRA
NIZAM
25.10.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
TOTAL PAX 1189 SQF.
UPDOWN
FIRST FLOOR PLAN
ELEVATION-7
SUITS 8FT
ELEVATION-9
SHOES6FT
TOILET
TRIAL
ROOM 1
PROPOSED
STAIRCASE
EXISTING
OPENING
TO BE
CLOSED
505 LIVID ECTASY PTR LAMINATE
OF GREEN LAM MAKE
850405
60
760
60
60
2470
60
650
500
60
2470
60
60
2457
75
739775500
1020
150
60
2470
60
415
60
1870
60
500
500
60
1870
60
8763105651500964
75
1140
500
DN
17. 01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
PARTITION LAYOUT
GROUND FLOOR
DRAWING NO : 05
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
567 SQF.
622 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
LOCATION :
KOLHAPUR
PARTITION LEGEND
75 MM THK. PARTITION WITH 50 MM X 50 MM
HARDWOOD FRAMEWORK AT 600 MM C/C
SPACING WITH 12 MM PLY ON BOTH SIDES.
60 MM WIDE BAND AND 500 MM WIDTH PORTALS MADE IN
TWO LAYERS OF 19 MM THK. COMMERCIAL PLY COVERED
WITH 10 MM THK. MDF ON BOTH SIDES AND FINISHED WITH
SUPER GLOSSY BLACK/WHITE LAMINATE FINISH
PORTAL DETAIL
500
60
40 MM SQUARE WOODEN BATTEN WITH
10 MM MDF BOARD ON THREE SIDES AS
VERTICAL FRAME FOR PORTAL TO BE
FINISHED WITH APPROVED SUPER
GLOSSY LAMINATE
P1
60 MM WIDE BAND AND 500 MM WIDTH PORTALS MADE IN TWO
LAYERS OF 19 MM THK. COMMERCIAL PLY COVERED WITH 10
MM THK. MDF ON BOTH SIDES AND FINISHED WITH
401 SUPER GLOSSY BLACK LAMINATE
75 MM THK. PARTITION WITH 50 MM X 50 MM HARDWOOD
FRAMEWORK AT 600 MM C/C SPACING WITH 12 MM PLY ON
BOTH SIDES.
60 MM WIDE BAND AND 500 MM WIDTH PORTALS MADE IN
TWO LAYERS OF 19 MM THK. COMMERCIAL PLY COVERED
WITH 10 MM THK. MDF ON BOTH SIDES AND FINISHED WITH
107 SUPER GLOSSY WHITE LAMINATE
19 MM THK. COMMERCIAL PLY BACKING
P2
P3
P4
CASH BACK
Touchscreen
Mouse
CASH
Touchscreen
Mouse
TRIAL
ROOM 1
ELEVATION-1
SPORTS12FT
505 LIVID ECTASY PTR LAMINATE
OF GREEN LAM MAKE
60
3670
60
UP
338
KARAAN R MEHRRA
NIZAM
25.10.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
TOTAL PAX 1189 SQF.
18. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
25.10.2012
REFLECTED CEILING LAYOUT
FIRST FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 06
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
N
KOLHAPUR
NOTES :
CEILING HEIGHT : 2400 MM
ASIAN MAKE : ACRYLIC
EMULSION (MORNING GLORY)
PROVIDE 19 MM THK.
COMMERCIAL PLY
ABOVE FALSE CEILING
FOR VM AND SIGNAGE
UPDOWN
TOILET
TRIAL
ROOM 2
DN
EXISTING
OPENING
TO BE
CLOSED
BACK ROOM
PORTAL HEIGHT : 2450 MM PORTAL HEIGHT : 2450 MM
PORTAL HEIGHT : 2450 MMPORTAL HEIGHT : 2450 MM
PORTALHEIGHT:2450MMPORTALHEIGHT:2450MM
CEILING HEIGHT : 2400 MM
ASIAN MAKE : ACRYLIC
EMLUSION (MORNING GLORY)
CEILING HEIGHT : 2610 MM
ACRYLIC EMLUSION DULUX
MAKE(CHARCOAL SLATE 30BB 21/014)
3418 413 1490 405 850
9452704005685
180
2310
8905495
150
1330
127573911362604305945
270
NO FALSE CEILING
19. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
25.10.2012
REFLECTED CEILING LAYOUT
GROUND FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 06
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
N
KOLHAPUR
NOTES :
CEILING HEIGHT : 2400 MM
ASIAN MAKE : ACRYLIC
EMULSION (MORNING GLORY)
PROVIDE 19 MM THK.
COMMERCIAL PLY
ABOVE FALSE CEILING
FOR VM AND SIGNAGE
UP
TRIAL
ROOM 1
PORTALHEIGHT:2450MM
PORTALHEIGHT:2450MM
CEILING HEIGHT : 2400 MM
ASIAN MAKE : ACRYLIC EMLUSION
(MORNING GLORY)
3740
7413174
7565
34203125850
2015 1255 405 1490 1240ENTRANCE
VISUAL MERCHANDISING
AREA
CEILING HEIGHT : 2625 MM
ACRYLIC EMLUSION DULUX
MAKE(CHARCOAL SLATE 30BB 21/014)
PROVIDE 19 MM THK.
COMMERCIAL PLY
ABOVE FALSE CEILING
FOR VM AND SIGNAGE
20. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
LIGHTING LAYOUT
FIRST FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 6
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR
DESCRIPTIONIMAGE
RLT SOLOR RECESSED WALL WASHER/
RLT CDHMFG RECESSED DOWNLIGHT
CFL 2X26W
RLT DIVA 70 W CDMT TRACK LIGHT
ONKYO CEILING MOUNTED SPEAKER
QTY.
2MTR. POWER TRACK
RLT LFL 28W 600MM FLUORESCENT
TUBE
RLT LFL 28W 1200MM FLUORESCENT
TUBE
1 MTR. POWER TRACK
18
27
00
00
20
04
08
LIGHTING LEGEND
AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
UPDOWN
ELEVATION-7
SUITS 8FT
ELEVATION-9
SHOES6FT
TOILET
TRIAL
ROOM 1
DN
ELEVATION-8
SUITS 6FT
EXISTING
OPENING
TO BE
CLOSED
731 1200 1200 1044
473
473
473
473473
1250 900 900 900 900 900
1250900900900900900696
900 900 900 900 900 685310
1250
1250
1250 1200 1200 900 675
675
750 1200 1200 1200 900 675
900 6751250 1200 1200 1200
1262 1200 1200
12509009009009008967001250
1250
1250
1250
1195900900371
760
1200 635 800
1250
15008965193069009001899
750
760
760
999
531531
490565
510510
563
900
356383
383361
549 549
430 448
332
649846
462 462
849
549549549549
1099 1649
499729
900885
900
849
9009008961950
21. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
NIZAM
22.10.2012
LIGHTING LAYOUT
GROUND FLOOR
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 6
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR
DESCRIPTIONIMAGE
RLT SOLOR RECESSED WALL WASHER/
RLT CDHMFG RECESSED DOWNLIGHT
CFL 2X26W
RLT DIVA 70 W CDMT TRACK LIGHT
ONKYO CEILING MOUNTED SPEAKER
QTY.
2MTR. POWER TRACK
RLT LFL 28W 600MM FLUORESCENT
TUBE
RLT LFL 28W 1200MM FLUORESCENT
TUBE
1 MTR. POWER TRACK
15
16
00
02
10
00
04
LIGHTING LEGEND
AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
ELEVATION-1
SPORTS12FT
CASH BACK
Touchscreen
Mouse
CASH
Touchscreen
Mouse
ELEVATION-4
VDOT 8FT
UP
PROPOSED
STAIRCASE
ELEVATION-3
VDOT 4FT
ELEVATION-6
VDOT 4FT
TRIAL
ROOM 1
1250 825
1200
9009009009009007611250
9009009007618999031248
596900
191
1250 1200 1200
220
886
898
1250 1200 1200
900596590
1250 1200 820
1250 1160 1200
1250 1160 1200 1200 1555
1250 1160 1200 1200 1200 1555
1250
1250
1250
8451250
1250845
1250
900
1250
983
562562
600600
590588
588
363 315
549549
849
549549
849
460 465
549 549
CEILING HEIGHT : 2625 MM
PAINTED DARK GREY
LOCATION :
KOLHAPUR
22. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
ELECTRICAL
LIGHTING LAYOUT
WITH CIRCUIT NO.
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 8
KOLHAPUR
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
NOTE:
CIRCUIT WIRING FOR LIGHTING TO BE DONE
WITH 3X2.5 Sq.mm Cu IN 25 MM DIA FRLS RIGID
PVC CONDUIT FROM DB TO SOCKET
EXHAUST/WALL MOUNTING WIRING TO BE DONE
WITH 2Rx2.5 Sq.mm +1Rx1Sq.mm Cu IN 25 MM DIA
FRLS RIGID PVC CONDUIT FROM DB TO SOCKET
SERVICE SOCKET WIRING TO BE DONE WITH 3Rx4
Sq.mm Cu IN 25 MM DIA FRLS RIGID PVC CONDUIT
FROM DB TO SOCKET
WIRING FOR MAIN FASCIA SIGNAGE TO BE DONE
WITH 3Rx2.5Sq.mm Cu IN 25 MM DIA FRLS RIGID
PVC CONDUIT FROM DB TO SOCKET
ONLY UPS SOCKETS AND 09NO.S OF EMERGENCY
LIGHTS TO BE CONNECTED TO UPS OF 2 KVA AS
PER LOAD DETAIL (.XLS FILE)
COLOUR CODING TO BE DONE AS PER
STANDARD WITH FERRULE NUMBERING AS PER
THE POWER DISTRIBUTION SCHEME
01.
02.
03.
04.
05.
06.
KEY DESCRIPTION QTY
ELECTRICAL LEGEND
& CODE
LDB-1 4 WAY TPN LIGHTING DISTRIBUTION
BOARD PLACE AT 1500MM FROM FFL
BRAND
36
1200 Flourescent tubes of Philips make
29
32
Recessed Downlight suitable for
CFL 2x18w
Recessed Wall Washer / Downlight
suitable for CDM-T 70w 30 degree
00Diva 70w, 30 DEG Spot Lights,
Track Mounted
600 Flourescent tubes of
Philips make 04
09SAME AS ABOVE BUT EMERGENCY
LDB-2 4 WAY TPN LIGHTING DISTRIBUTION
BOARD PLACE AT 1500MM FROM FFL
UPDOWN
GROUND FLOOR
PLAN
FIRST FLOOR PLAN
CASH BACK
Touchscreen
Mouse
CASH
Touchscreen
Mouse
TOILET
TRIAL
ROOM 2
DN
EXISTING
OPENING
TO BE
CLOSED
TRIAL
ROOM 1
ENTRANCE
DN
LDB-1
LDB-2
L11
L21
L31L41
L51
L81
L91
L71
L61
L101
L12
L32L22
L42
L52
L62
L82
L92
L72
L122
L112
L102
23. UPDOWN
GROUND FLOOR
PLAN
FIRST FLOOR PLAN
ELEVATION-1
SPORTS12FT
CASH BACK
Touchscreen
Mouse
CASH
Touchscreen
Mouse
ELEVATION-7
SUITS 8FT
ELEVATION-9
SHOES6FT
ELEVATION-4
VDOT 8FT
TOILET
TRIAL
ROOM 2
DN
ELEVATION-8
SUITS 6FT
EXISTING
OPENING
TO BE
CLOSED
ELEVATION-3
VDOT 4FT
ELEVATION-6
VDOT 4FT
TRIAL
ROOM 1
ENTRANCE
DN
LDB-1
PDB-3
P3/B1/3
KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
POWER/DATA,
VOICE LOCATION
PLAN LAYOUT.
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 9
KOLHAPUR
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
NOTE:
CIRCUIT WIRING FOR LIGHTING TO BE DONE
WITH 3X2.5 Sq.mm Cu IN 25 MM DIA FRLS RIGID
PVC CONDUIT FROM DB TO SOCKET
EXHAUST/WALL MOUNTING WIRING TO BE DONE
WITH 2Rx2.5 Sq.mm +1Rx1Sq.mm Cu IN 25 MM DIA
FRLS RIGID PVC CONDUIT FROM DB TO SOCKET
SERVICE SOCKET WIRING TO BE DONE WITH 3Rx4
Sq.mm Cu IN 25 MM DIA FRLS RIGID PVC CONDUIT
FROM DB TO SOCKET
WIRING FOR MAIN FASCIA SIGNAGE TO BE DONE
WITH 3Rx2.5Sq.mm Cu IN 25 MM DIA FRLS RIGID
PVC CONDUIT FROM DB TO SOCKET
ONLY UPS SOCKETS AND 09NO.S OF EMERGENCY
LIGHTS TO BE CONNECTED TO UPS OF 2 KVA AS
PER LOAD DETAIL (.XLS FILE)
COLOUR CODING TO BE DONE AS PER
STANDARD WITH FERRULE NUMBERING AS PER
THE POWER DISTRIBUTION SCHEME
01.
02.
03.
04.
05.
06.
POWER DISTRIBUTION BOARD 4 WAY TPN
150x150x38mm FLOOR BOX FOR DATA/VOICE/POWER
2x6A SWITCH SOCKET OUTLET (UPS)
1x6A SWITCH SOCKET OUTLET (RP)
1x16A SWITCH SOCKET OUTLET FOR SERVICE/AC(RP)
2D2V
2 DATA/2VOICE IN E-CAT (6) DUAL FACE PLATE
20A-PNE- INDUSTRIAL SOCKET
CONTROLLED BY 20A SP MCB FOR SPLIT AC
PDB-3
LIGHTING DISTRIBUTION BOARD 4 WAY TPN
LDB-1
LIGHTING DISTRIBUTION BOARD 4 WAY TPN
LDB-2
24. 32A TPN6WAY TPN
01 03
01 06
LDB-1,2
MCB
05 1009 B.EB.E
3Rx2.5 Sqmm Cu
03 04 07 08 11 1202
CT'S
FUSE
INDICATING LAMP
VOLTMAPS/KALPA
GEC/STD
VAISHNOV
L&T/GE/ABBMCCB
MAKE OF COMPONENTS
5
3
4
2
6
7 PROK DEVICESELR
1
MCB MDS
WALL MOUNTING
SIDE/BOTTOM
TOP
IP-42 DEGREE
2.5sq.mm PVC Cu. CABLE
6
2
4
3
CUBICLE TYPE
7
SCHEDULE
INSULATION
SUPPORT
BUSBAR
NEUTRAL
PHASE
EARTHING
PROTECTION
ENCLOSURE
OUTGOING CABLE
INCOMING CABLE
SHEET STEEL USED 14swg CRCA
FRP/HYLAM
COLOR CODED PVC SLEEVES
COPPER
PAINT SHADE
HARD WARE ZINC YELLOW PASSIVATED
EPOXY POWDER COATING
NAME PLATE ALUMINUM ANODIZED5
8
10
9
12
13
11
14
15 CONTROL WIRING
1Rx 12 x 3mm
1Rx 20 x 4mm
1Rx 20 x 4mm
LOCATION16 BACK OFFICE
1 (ONE)17 QTY
(SIEMENS GREY)
MDM NEW HORIZON
KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
25.10.2012
LIGHTING & POWER
SINGLE LINE
DISTROBUTION
SCEME
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO :10
KOLHAPUR
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
ABBREVIATION
PHASE INDICATOR LAMP
EARTH LEAKAGE RELAY
MINIATURE CIRCUIT BREAKER (MCB)
MOULDED CASE CIRCUIT BREAKER
SYMBOL
ELR
EM ENERGY METER
THE FOLLOWING SHOULD CONFIRM TO:
STANDARDS
SUB MAIN POWER PANEL
LOCATION: BACK STORE
27. FRONT FACADE
KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012
FRONT FACADE
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 22
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
+190MM
+360MM
+530MM
+720MM
12 MM THK TOUGHENED
GLASS
4MM THK BLACK
ACP(MATT)
PARAPET WALL
5301502190940150
BEAM DROP
370MM
UNFINISHED FLOOR
SECTION
ELEVATION A
FRONT FACADE ELEVATION
1900450850
12 MM THK TOUGHENED
GLASS
C:UsersDIVYADesktopPicture-1-4.jpg C:UsersDIVYADesktopgirl4.jpg
28. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
05.11.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 15
KOLHAPUR
NOTES:
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
FRONT FACADE
DETAIL
GLASS FIXING DETAIL
ON CEILING
SILICON GEL
12 MM THK. GYPSUM FALSE
CEILING.
STANDARD EXTRUDED
ALUMINIUM U-CHANNELS.
BEADING
12 MM THK. TOUGHENED GLASS TO BE
FIXED ON CONCEALED U-CHANNELS
ON FLOOR.
FRAMEWORK TO SUPPORT CHANNELS
FOR GLAZING.
GLASS FIXING DETAIL
ON FLOOR
12 MM THK. TOUGHENED GLASS TO BE
FIXED ON CONCEALED U-CHANNELS
ON FLOOR.
SILICON GEL
STANDARD EXTRUDED ALUMINIUM
U-CHANNELS.
LINE OF ROLLING SHUTTER
ROLLING SHUTTER GUIDE WITHIN
THE BOXING MOUNTED OVER
NECESSARY SUPPORTS
19 MM PLY BOXING
DETAIL A
100
450
LINE OF TRAP DOOR
ON HINGE
TRAP DOOR
29. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
05.11.2012
STAIRCASE DETAIL
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 16
KOLHAPUR
NOTES:
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
UPDOWN
B'
A'
A
2603985
GROUND FLOOR PLAN
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
EXISTING BEAM DROP DOWN
AT 2775 MM FROM UFFL
B.O.S AT 3200 MM
FROM UFFL
EXISTING WOODEN PARTITION
A'
UP
955
250 250 250 250 250 250 250
850
75
BRACKETS
FOR FIXING 12MM THK GLASS
( HAIRLINE FINISH)
12 MM TOUGHENED GLASS FIXED WITH
BRACKETS (HAIRLINE FINISH)
3 MM WALL THICKNESS,
HAIRLINE FINISH
3 MM WALL THICKNESS,
HAIRLINE FINISH
SS PIPE GROUTED
MIN 100MM DEPTH
50
6MM GROOVE
DETAIL B - BALUSTER DETAIL
3M ANTI-SKID STRIP
2 MM THICK & 30 MM WIDE
4 MM X 4 MM CONTINUOUS REVEAL
20MM THICK BLACK GRANITE
250
RCC RISER
RCC TREAD
182
DETAIL A - TREAD AND RISER DETAILS
SECTION AA
DETAIL A
DETAIL B
150
3200
2451100
955
250 250 250 250 250 250 250
1100250250250250250250250250
250
SLAB CUT OUT FOR STAIRCASE
2846
EXISTING WINDOW IS
TO BE CLOSED
FIRST FLOOR PLAN
HAIRLINE FINISH
SLAB CUT OUT FOR STAIRCASE
HAIRLINE FINISH
250
235
2502502502502502502501100
RISERS - 182 MM
TREAD - 250 MM
30. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
05.11.2012
TRIAL ROOM DETAIL
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 17
KOLHAPUR
NOTES:
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
E G
F
H
OPEN
OPEN
ELEVATION E ELEVATION F ELEVATION GELEVATION H
3002000
12MM GYPBOARD CEILING@ 1900 MM
HANGING HOOK
100MM SS TILE SKIRTING
75MM THk PARTITION IN 50X50MM
SALWOOD FRAME WITH 12MM PLY
BOTH SIDES AND INSIDE FINISHED
WITH 1MM THK 505 LIVID ECTASY
PTR LAMINATE
OF GREEN LAM MAKE
6MM THK MIRROR OF SIZE 900 MM X
2000 MM
6MM THK MIRROR OF SIZE 900
MM X 2000 MM
75MM THk PARTITION IN 50X50MM
SALWOOD FRAME WITH 12MM PLY BOTH
SIDES AND INSIDE FINISHED WITH 1MM THK
505 LIVID ECTASY PTR LAMINATE
OF GREEN LAM MAKE
100MM SS TILE SKIRTING
25MM THK PLY DOOR WITH
5MM THK BLACK ACRYLIC
OUTSIDE AND 1MM THK 107
WOOL LAMINATE OF
GREENLAM MAKE INSIDE
12MM GYPBOARD CEILING@
1900 MM
100
TRIAL ROOM KNOB
3002000
100
3002000
100
3002000
100
100
75
938
123
TRIAL ROOM
100
750
75
75
938
123
78
900
78 75
FIRST FLOOR TRIAL
ROOM PLAN
A C
D
B
ELEVATION B
OPEN
OPEN
ELEVATION A
12MM GYPBOARD CEILING@ 1900 MM
100MM SS TILE SKIRTING
6MM THK MIRROR OF SIZE 900 MM X
2000 MM
25MM THK PLY DOOR WITH
5MM THK BLACK ACRYLIC
OUTSIDE AND 1MM THK 107
WOOL LAMINATE OF
GREENLAM MAKE INSIDE
75 MM THk PARTITION IN 50X50MM
SALWOOD FRAME WITH 12MM PLY BOTH
SIDES AND INSIDE FINISHED WITH 1MM
THK 505 LIVID ECTASY PTR LAMINATE
OF GREEN LAM MAKE
TRIAL ROOM KNOB
3002000
100
3002000
100
12MM GYPBOARD CEILING@ 1900 MM
100MM SS TILE SKIRTING
75MM THk PARTITION IN 50X50MM
SALWOOD FRAME WITH 12MM PLY
BOTH SIDES AND INSIDE FINISHED
WITH 1MM THK 505 LIVID ECTASY
PTR LAMINATE
OF GREEN LAM MAKE
6MM THK MIRROR OF SIZE 900 MM X
2000 MM
HANGING HOOK
ELEVATION C ELEVATION D
TRIAL ROOM
3002000
100
75112
750263
75
75
1042
123
75112
900
11375
GROUND FLOOR
TRIAL ROOM PLAN
31. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012
TRIAL ROOM MIRROR
DETAIL
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 22
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
1925105
10
2040
E
ILLUMINATION
100
15 15
100
MIRROR
60
1909105
10
15
2040
10015
80
MIRROR
BELT
DETAIL AT A
DETAIL AT A
SECTION
E
ILLUMINATION
E
ILLUMINATION
KOLHAPUR
32. 25
425
450
25
350
25
400
25
350
25
400
25
425
450
PLAN
ELEVATION
STAINLESS STEEL
BRUSHED
WOODEN CUBE
WRAPPED WITH FABRIC
KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012
POUFFE DETAIL
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 34
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
DATE :
33. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 20
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
CASH COUNTER DETAIL
34. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 21
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
CASH COUNTER VIEW
35. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 22
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
50
1000
1050
UPPER TOP_BLACK LAMINATE
ALTERNATIVELY_BLACK CORIAN
UPPER TOP_BLACK LAMINATE
ALTERNATIVELY_BLACK CORIAN
ALL INTERIOR LACQUERED BLACK
RAL 9005 MATT FINISH
FLEXIBLE SHELF
PULLOUT SHELF
MUSIC SYSTEM
SPACE FOR WOOFER
STAINLESS STEEL BRUSHED
fabric bags
folding boxes
bags
paper
tissue paper
49010
500
B
B A
A
19
700 406
BACK COUNTER/ELEMENT FOR
PAPER ETC
1125
PLAN
19
176
19
177
19
177
19
177
19
17721
FRONT FINISHES LACQUERED
BLACK RAL 9005_HIGH GLOSS
ALL INTERIOR_LACQUERED
BLACK RAL 9005_MAT FINISH
BORING IN LINE
MUSIC SYSTEM
SPACE FOR WOOFER
STAINLESS STEEL BRUSHED
500
490
50
1000
1050
10
10
25
FLEXIBLE
SHELF
19
75
FRONT ELEVATION
SECTION AA
10
19
fabric bags
folding boxes
bags
paper
tissue paper
19
STAINLESS STEEL BRUSHED
ALL INTERIOR-LACQUETED BLACK
RAL 9005-MATT FINISH
SECTION BB
NICHE
10 490
500
CASH BACK DETAIL
36. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012
PRESENTATION
TABLE(SMALL) V.DOT
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 23
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
37. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012
PRESENTATION TABLE
(SMAL)VH
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 23
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
38. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 25
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
1190400
400
60
1080
60
FOLDED
MERCHANDISE ON
TOP
60
1070
6010
1200
330
40
330
40
330
60101130
601200
400
COUNTER WEIGHT
WELDED ON STEEL
PLATE FOR STABILITY
PLAN SECTIONAL PLAN
FRONT VIEW SIDE VIEW SECTIONAL VIEW
10
COTTON TROUSER
CDU VH SPORT
39. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 26
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
F:Mansoor November 1-11-2012Van Heusenvanheusen_logo.jpg
1190400
400
60
1080
60
FOLDED
MERCHANDISE ON
TOP
60
1070
6010
1200
330
40
330
40
330
6010
1130
60
1200
400
COUNTER WEIGHT
WELDED ON STEEL
PLATE FOR STABILITY
PLAN SECTIONAL PLAN
FRONT VIEW SIDE VIEW SECTIONAL VIEW
10
LACQUERED BLACK
GLOSSY
COTTON TROUSER
CDU VH
40. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012
FREE STANDING RACK
DETAIL
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 27
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
ELEVATION
TOP VIEW
TOP VIEW
ELEVATION
RECTANGULAR TUBE:
15 MM X 40 MM
STAINLESS STEEL
BRUSHED
RECTANGULAR TUBE :
15 MM X 40 MM
STAINLESS STEEL
BRUSHED
40
1270
40
1350
40
1270
40
15
1220
151250
10
183
15
183
10
390
390
40
172
15
163
10
400
41. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
NIZAM
05.11.2012
PORTAL DETAIL
DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 28
KOLHAPUR
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
15 MM GROOVE IN
SKIRTING 12MM MDF OVER 19MM MDF BOARD
TO CREATE GROOVE AT BOTTOM
19MM MDF BOARD AS BOTTOM OF PORTAL
BACK PANEL OF WALL RACK
30 MM WIDE , 10 MM THICK 080 ACRYLIC SHEET
FIXED 10 MM X 10 MM BRUSHED S.S ANGLE.
150 MM WIDE BOX MADE UP
OF 19MM MDF BOARD
T-8 TUBE LIGHTS OF APPROVED COLOR
(CONCEALED)
FALSE CEILING AT 3000 MM FROM FFL.
40 MM SQUARE WOODEN BATTEN WITH 10 MM MDF
BOARD ON THREE SIDES AS VERTICAL FRAME FOR
PORTAL TO BE FINISHED WITH APPROVED COLOR
OF DUCO PAINT
VARIABLE
PLAN
A
A
ELEVATION
SECTION A-A
60
500
10 4010 10
40
10
1560
2450
60504
365
1560
2450
110
4
365
4 MM OFFSET FROM THE PORTAL
19 MM THK. PLY FINISHED WITH DUCO PAINT
OF APPROVED COLOUR.
19 MM THK. PLY FINISHED WITH PAINT OF APPROVED
COLOUR.
42. KARAAN R MEHRRA
01 THIS DRAWING IS THE COPYRIGHT OF
THE ARCHITECTS AND IS NOT TO BE REPRODUCED
COPIED,HANDED OVER TO THIRD PARTY
OR USED FOR ANY OTHER PURPOSE,OTHER
THAN FOR WHICH IT IS HANDED.
NOTE :
02 ALL DIMENSIONS SHALL BE COUNTER CHECKED
ON THE SITE PRIOR TO START OF WORK.
03 WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
04 ANY DATA REQUIRED SHALL BE CONFIRMED
FROM THE ARCHITECT PRIOR TO START OF WORK.
05 THIS DRAWING SHALL BE READ IN CONJUNCTION
WITH OTHER PERTINENT DRAWINGS.
06 IN CASE OF ANY DISCREPANCY THE SAME
SHALL BE REFERRED TO THE ARCHITECT.
DRAWING TITLE :CAUTION :
WHILE EVERY ATTEMPT HAS BEEN MADE IN THE
PREPARATION OF THIS DRAWING TO AVOID
MISTAKES,THE MAKER CANNOT GUARANTEE
AGAINST HUMAN ERROR.
THE CONTRACTOR ON THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS,
PRIOR TO COMMENCEMENT OF WORK AND
SHALL BE RESPONSIBLE FOR THE SAME.
LOCATION :
MANSOOR
05.11.2012DATE :
SCALE :
DRN.BY :
APPD.BY :
NTS
DRAWING NO : 29
KOLHAPUR
NOTES:
SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM
ANGLED STORAGE
WITH MIRROR
60
457
62
406
62
406
62
406
62
527
60
2450
60
1870
60
500
BLACK GLOSSY DUCO
WHITE LAMINATED SLANTED SHELF
WHITE LAMINATED BACK PANEL
WITH HORIZONTAL CHANNEL
PLAN
FRONT ELEVATION
12 MM GYPSUM FALSE CEILING
AT 2610MM
REFERENCE IMAGE
FFL
62 MM X 300 MM TRIANGULAR SHELF WITH
10 MM GREY PARASOL GLASS ON TOP
62
300
450 450
ANGLED STORAGE
WITH MIRROR
SHOE WALL DETAIL
43. SIGN OFF BY CLIENT
FOR APPROVAL
FOR COSTING
FOR CONSTRUCTION
DRAWING STATUS
FOR DISCUSSION
SUMMARY
FLOOR AREA
INSQF.
GROUND FLOOR
FIRST FLOOR
TOTAL PAX
567 SQF.
622 SQF.
1189 SQF.
1. GROUND FLOOR BOS - 3200 MM
3. ALL DIMENSIONS ARE IN MM
FIRST FLOOR BOS - 3130 MM
2. GROUND FLOOR BOB - 2775 MM
FIRST FLOOR BOB - 2760 MM