Fuel Prices and Calorific Value
Fuel Price (Rs./Kg) Calorific Value (Kcal/Kg)
Furnace Oil 30 10200
HSD 52 10800
Natural Gas 40 8500
Coal 7 5500
Petcoke 9 8000
Rice Husk 3.5 3200
Briquette 5.5 4000
Boiler Efficiency & Cost of Steam
Fuel Avg S:F Avg Cost of Steam (Rs./Kg)
Furnace Oil 12 2.25
HSD 13 4
Natural Gas 12 3.5
Coal 4.5 1.5
Petcoke 7 1.2
Rice Husk 3.2 1.2
Briquette 3 1.8
Optimal Steam Generation System
Meeting the process demands in
a manner which is:
Copyright Forbes Marshall, 2009-
10
Steam & Condensate Loop
100% fuel
energy
80%steam
3% distribution losses
77%
Process
consumption 57%
20%
Unburnt
Stack
Blowdown
Steam Generation-Boiler
House
• Criteria for Selection of Boiler
- Steam Demand : Peak /Average
load
- Steam Consumption pattern
- Fuel selection w. r. t. availability,
cost
- Feasibility of COGEN
Copyright Forbes Marshall, 2009-
10
Copyright Forbes Marshall, 2009-
10
Cost of operation-Solid fuel
Copyright Forbes Marshall, 2009-
10
Cost of operation–OilGas
fuels
Copyright Forbes Marshall, 2009-
10
Measured Losses
Boiler Efficiency – Perception & Reality
86%
78%
74%
78%
70%
65%
60%
65%
70%
75%
80%
85%
90%
Oil Solid
Ideal
Indirect
Direct
8%
4% 8%
5%
Copyright Forbes Marshall, 2009-
10
An increase of 2% efficiency in a 5 TPH boiler results in a saving of 53,200 liters of
oil per year !
Factors affecting boiler
efficiency
Copyright Forbes Marshall, 2009-
10
Comparison of Efficiency Methods
• Direct Efficiency
• Useful Heat output / total
heat input
• Covers all losses
• Simple to implement
• Instrument accuracy has a
significant affect on final
efficiency
• In Direct Efficiency
• Efficiency = 100 – Losses
• Considers Stack, Enthalpy,
Radiation, Blowdown and
unburnt losses
• Gives detailed break up of
losses
• Not affected too much by
instrument accuracy
Copyright Forbes Marshall, 2009-10
Real life scenario
• The measured efficiency of Process boilers varies a lot
Min. Avg. Max.
Direct Efficiency 61 % 72 % 82 %
Indirect Efficiency 63 % 78 % 84 %
• Efficiency is dynamic – It WILL keep on changing.
Copyright Forbes Marshall, 2009-
10
What leads to variations
• Air temperature
• Fuel temperature
• Fuel pressure
• Moisture in fuel
• Loading pattern
• Changing calorific value of fuel
• Use of multiple fuels
Innovative Oil / Gas fired Boilers
Site Installations…
Site Installations…
Site Installations…
Site Installations…
Manual Fired Boilers – Limitations !!
• Indirect Efficiency Guaranteed 73 – 77%
• Typical Direct Efficiency obtained 50-55%
– More heat loss by radiation and convection during fuel feeding cycle
resulting in lesser actual efficiency
– Distribution of fuel on furnace grate is uneven leading to Empty
pockets and fuel overloaded pockets possible
– Operators tend to overfeed resulting in incomplete combustion
• Manual fuel feeding is laborious and time consuming
• The operator gets exposed to hot flames
• These boilers can not be designed for higher pressure beyond 28 kg/cm2.
24
Observations in Manual Fired Boilers
• High stack temp of up to 249 Deg c @ 6 bar (g) causing heat carry
over loss.
• High O2 percentage - ~ up 10 (charged) -19 (discharged)%
• Indirect efficiency – 65.3 % (@ 50% fix damper)
Direct efficiency–50 %
• Optimum Air : Fuel ratio is not maintained
25
26
Date
Operating
hrs
Day wise Readings
Steam
generation
(kg)
Avg steam
load
(kg/h)
Wood
consumptio
n
(kg)
S:F
13/10/10 12 4355 363 1607.4 2.70
15/10/10 10 4503 450.3 1441.8 3.12
16/10/10 4 2333 584 834 2.79
26/10/10 10 4906 490.6 1790 2.74
28/10/10 10 4414 441.4 1840 2.39
30/10/10 11 6561 597 1785
3.67
*
31/10/10 12 7883 657 2050
3.84
*
1/11/10 – IInd
shift
5 1892 378.4 920 2.05
AVERAGE Steam : Fuel Ratio 2.85
S:F Ratio with Manual Fired boiler
Gap Between
Minimum and
maximum S:F is
100%
Gap between
average and
mimimum is
40%
Stack , 26%
Unburnt ,
9.80%
Enthalpy, 11%
Radiation,
1.50% Ash, 1.75% Unaccounted,
0.25%
Losses in Percentage
Typical Break-up of Losses
• Stack Loss –
Frequent Opening & closing of door
ID Fan damper position same for all stages of operation of
boiler.
• Unburnt Loss –
Overfeeding of fuel resulting in low air for Burning which also
leads to high amount of Unburnt generation.
• Enthalpy Loss – Moisture in fuel & Air results in this loss.
• Radiation Loss –
Through Boiler Heating Surface areas – no Major control possible
Deep Dive into the Losses…..
Current Scenario
• Variety of Boiler designs like Wet Back/Semi Wet Back & Dry
Back
• Converted external furnace boilers with deaerated capacity &
with Big gap in efficiency
• Quality of Accessories used on Solid fired boilers ????
• No Automation provided, hence total reliance on operator
skills
 O2 Levels – 9 – 11%
 Excess Air - @70%
 Furnace pressure – Between -5 to - 8 mmWC
What should we AIM for ?
Fuel Feeding practices
•The boiler operator looks at steam
pressure and does the fuel feeding
accordingly.
•Stoker mostly overfeeds fuel as
per his convenience & Grate space.
Irrespective of plant load, the grate
is usually filled fully. This results in
high un-burnts and stack loss
Current Operating Practices in
Manual Fired boilers
Fuel Feeding practices
• After feeding, the window is closed &
fuel burns incompletely for some time
leading to high unburnts as can be
seen from the black chimney smoke
colour during feeding
• Thereafter, the fuel burns and is fed
at a later stage by that time stack
losses start to happen.
Current Operating Practices in
Manual Fired boilers
Need Of The Hour based on
Today’s Limitations in the Industry
• To provide information & Alerts – to assist the boiler
operator for efficient boiler operation.
• To provide information to utility manager on – How the
boiler was operated on Daily, weekly & monthly basis.
• To generate MIS so as to follow better operating practices in
boiler house for reduced fuel bills
• To provide periodic maintenance alerts to enhance life of
boiler & reduce on forced break downs.
With IntellGeneral operating practice
PHASE I: IMMEDIATELY AFTER FEEDING
• Fuel is overfed
• Bed not evenly spread
• Black/dark grey smoke
observed
• High unburnt loss (High CO
levels)
• Stack O2 levels: 0-5%
• Fuel feed optimised
• Bed is evenly spread
• Light grey/light Brown observed
• Low CO levels
• Stack O2 levels: 5-7%
4-
5
mi
nu
te
2-
3
mi
nu
te6% Stack
O
6% Stack
O
With IntellGeneral operating practice
PHASE II: AFTER FEEDING (contd.)
• Large interval between fuel
feeds
• Uneven bed
• Greyish-white smoke observed
• Stack O2 levels: 5-10%
• High feeding frequency
• Light grey/light Brown smoke
observed
• Stack O2 levels: 6-10%
10-
14
mi
nut
es
8-
10
mi
nu
te6% Stack
O
6% Stack
O
General operating practice With Intell
PHASE III: AFTER FEEDING (contd.)
• High feeding frequency
• Light grey/light Brown smoke
observed
• Stack O2 levels: 8-12%
4-
5
mi
nu
te
2-
3
mi
nu
te6% Stack
O
6% Stack
O
• Large interval between fuel
feeds
• Uneven bed
• White smoke observed
• High stack loss (High O2%
levels)
• Stack O2 levels: 8-18%
Furnace Draft pressure
• Boiler Furnace draft is maintained
by guess-work and there is no
measurement of it. Improper Boiler
draft results in improper combustion
and risk of back firing and increased
unburnt loss.
• Manual damper adjustments are
based on expertise and vigilance
Current Operating Practices in
Manual Fired boilers
So what can be done go close to level
of comitted Indirect Efficiency levels??
• Continuous Monitoring of Boiler parameters
• Generating Pop ups for corrective actions to
be taken by boiler operator
• Provide History & trends to utility manager for
the boiler operations, which can suggest a
necessary change in operations of boiler
38
Intelligent Boiler
39
PLC Based HMI Display with POP UPS
Facts & Figures!!• 2% decrease in O2 leads to 4% increase in Boiler Efficiency.
• Every 6 deg C increase in Feed water temperature means 1%
less fuel bill.
• 20 Deg C variation in stack temperature from optimum value
means 1% increased fuel consumption
• Presence of 1% unburnt represents 2.5% excess fuel
consumption.
• 3mm soot deposition on tubes increases fuel consumption by
2%
• Maintaining optimum water TDS avoids scaling, moisture
carryover in steam & increase operating Efficiency.
Pop ups
1. Feed fuel
2. Close the door
3. Open damper
4. Close damper
5. Clean the tubes
6. Reduce feed
7. Stir/poke the fuel bed
8. Check condensate recovery
9. Avoid sudden loading
10. Excess steam demand
11. Possible back fire
12. Improve water quality
13. Drain mobrey
14. Mobrey not drained
15. Clean the TDS sensor
Safety
Boiler Efficiency
Good operating practices
Feed fuel
Condition:
1. Steam pressure is lesser than
the set lower limit.
2. Gap between stack
temperature & steam
temperature is less than 50 C
3. Boiler door is closed
Condition:
Door open for more than 5 minutes.
Close the
door
Possible
Back-fire
Condition:
Furnace pressure goes positive
Intell – Management Tool!!
• Min – Max values of
important parameters
can be seen on
Daily/weekly/Monthly
basis
• History & Trends of two
years of operation of
boiler can be seen
• Data on Number of
alarms generated,
addressed can be seen.
Summary Screen
• Gives a summary for current day and last day of the number of alarms
occurred and how was the health associated to a particular parameter.
• The heath number is an indication of the response time of the operator
 Incorporate automated feeding for feeding fuel in Furnace
 Feed only the required quantity of fuel
 Ensure even spread of fuel over the bed
 Modulation of air to fuel ratio
 Control the air flow during operation cycle
47
How do we ACHIEVE this?
Automation –Need of
Hour!!
Automation of –
• Fuel feeding mechanism
• Damper movement
Objective..
49
Capacity – 1/2/3/4/4.5TPH
Pressures – 10.54 / 14.5 / 17.5 kg/cm2(g)
Fuel – Briquette/Coal/Wood Chips
MS-HD DTB
Copyright Forbes Marshall, 2009-
10
Online Efficiency Monitoring
Copyright Forbes Marshall, 2009-
10
Online Efficiency Monitoring
Copyright Forbes Marshall, 2009-
10
Generation
Opportunity Description
Generate steam at rated pressure Operating at lower pressure results in reduced output and carryover.
Minimize excess air Reduces the amount of heat lost up the stack, allowing more of the fuel
energy to be transferred to the steam
Clean boiler heat transfer surface Promotes effective heat transfer from the combustion gases to the
steam
Maintain high feedwater temperature High Feedwater temperature drives out dissolved oxygen
Size feedwater tank correctly As thumb rule, feedwater tank should be sized to be 1.5 times the peak
steam demand
Avoid oversizing the boiler Oversizing leads to frequent On-Off cycles in a boiler which lowers
boiler efficiency
Monitor Boiler Parameters Continuous monitoring of boiler parameters for optimized boiler
efficiency
Install heat recovery equipments (feedwater
economizers/combustion air preheaters,
blowdown heat recovery)
Recovers available heat and transfers it back to the system by
preheating feedwater or combustion air.
Similarly apart from controlling blowdown, heat can be recovered from
blowdown that is done.
FM Solid Fuel Fired Boilers
Hinged
Doors for
ease of
maintenance
FM Solid Fuel Fired Boilers
Factory
Insulation &
Cladding
FM Solid Fuel Fired Boilers
Structurals &
Platforms –
Packaged
Boiler
Feed Water
Pumps on Skid
FM Solid Fuel Fired Boilers
600 kg/ hr
Boiler
(Dryback)
FM Solid Fuel Fired Boilers
Packaged
Boiler)
FM Solid Fuel Fired Boilers
Twin Flue
Boiler
Ash Doors
FM Solid Fuel Fired Boilers
FM Solid Fuel Fired Boilers
FM Solid Fuel Fired Boilers
Individual Lines
for Feed Water
FM Solid Fuel Fired Boilers
FM Solid Fuel Fired Boilers
FM Solid Fuel Fired Boilers
Site Installations
Schreiber Dynamix Dairy Baramati
PO Date – 8th April 2013
Commissioning Date – 4th Dec 2013
Copyright Forbes Marshall, 2009-
10
Steam Distribution
• Pipe Sizing & Layout
- Check adequacy & recommend improvement
- Identify redundant piping & optimise layout for reduced losses.
• Insulation
- Check adequacy & estimate losses
- Recommend improvements
• Air Venting
- Identify locations
- Recommend right type, size & quantity
• Metering
- Identify locations
- Recommend right type & size.
• Trapping
- Trap survey & recommendations
- Estimation of loss through leaks
- Recommendations of trap monitoring
Steam pipe layout
Copyright Forbes Marshall, 2009-
10
Steam
CORRECT
INCORRECT
Steam
Steam Mains –Condensate
drain
Copyright Forbes Marshall, 2009-
10
Condensate to Steam trap
INCORRECT
Flow
Flow
CORRECT
Condensate to Steam trap
Steam
Pocket
Importance of Correct Pipe
Sizing
Copyright Forbes Marshall, 2009-
10
Insulation
Copyright Forbes Marshall, 2009-
10
Need for Air Venting
Copyright Forbes Marshall, 2009-
10
Air Venting….
Copyright Forbes Marshall, 2009-
10
Copyright Forbes Marshall, 2009-
10
Distribute at High Pressure
This will have the following advantages:
– Smaller bore steam mains needed so less heat (energy) loss due to
smaller surface area.
– Lower capital cost of steam mains, both materials such as pipes, flanges
and support work and labour.
– Lower capital cost of insulation (lagging).
– Dryer steam at point of usage due to drying effect of pressure reduction
taking place.
– Boiler can be operated at higher pressure corresponding to its optimum
operating condition, thereby operating more efficiently.
– Thermal storage capacity of boiler increases, helping to cope more
efficiently with fluctuating loads, & a reduced risk of priming & carryover
Copyright Forbes Marshall, 2009-
10
Pressure Reducing Station
Copyright Forbes Marshall, 2009-
10
Electro-pneumatic Temp
control
KE valve with PN actuator and EP5 Positioner
SX65 Controller
EL2270 Sensor
Pneumatic power and electronic intelligence
on a steam to liquid heat exchanger
Copyright Forbes Marshall, 2009-
10
Trapping Issues
Not Fit For Purpose
Plant Start Up
Not in service
Copyright Forbes Marshall, 2009-
10
Commonly Prevailing
• Failed Closed
• Failed open
• Not in service
• Not fit for purpose
• Installation
Copyright Forbes Marshall, 2009-
10
The cost of Leaks??
Cost of Steam Leaks….
Copyright Forbes Marshall, 2009-
10
Copyright Forbes Marshall, 2009-10
Maintenance addresses only 20%!
20%
Maintenance
Procedures
40%
Improper
Selection/
Installation
20%
Site Conditions
20%
Manufacturing
Defects
Copyright Forbes Marshall, 2009-
10
Steam Trap Selection Criteria
Steam Application Present type of Trap Benchmark Key Selection Factor
Steam Main Line Drain Thermodynamic (TD) Thermodynamic (TD)
Quick condensate
removal
Steam Tracing for
product line
Thermodynamic (TD)
Balance Pressure
Thermostatic (BPT)
Energy
Conservation
Copper Tracing for
instrument tracing
No Traps Thermostatic (MST)
Energy
Conservation
Process Heating
Equipments
TD / IB / FT
Mechanical (Float
Trap - FT)
Process Efficiency
and time
Pump Casing Thermodynamic (TD) Thermodynamic (TD)
Quick condensate
removal
Steam trap selection….
Copyright Forbes Marshall, 2009-
10
Copyright Forbes Marshall, 2009-
10
Compact Steam Trapping Station
Estimated weight : 13 kg 4.0 kg
Assembly Parts & Labor
5 ea. 600# rated globe or gate valves 1 ea. Line strainer
8 ea. Sch 80 nipples 16 ea 1/2’’ welds
2 ealine “tee” 1 ea. Steam trap
1 ea. elbow
CONVENTIONAL
720mm
160 mm
245mm
Modern Process Trap Assembly
TOFTIntegrated design for base
and Cover
PRODUCT MARKING
Aesthetic Features
Modern Float Trap Assembly
TOFT
TOFT VIEWS
Copyright Forbes Marshall, 2009-
10
Glandless Piston Valves
FEATURES
– CLASS VI, BUBBLE TIGHT SHUT-OFF
Ensures Positive Isolation
– SS REINFORCED GRAPHITE SEALING
RINGS
Asbestos free Sealing rings,
– FORGED CS BODY FOR SIZES UPTO 1
½”
Max. Pressure : 78 Kg/cm2
Max. Temperature : 427 °C
OPTIMIZING HEAT RECOVERIES
Waste Heat Recovery
• Important & unexplored area for reducing
energy
• Around 20 to 50% industrial energy input is
lost as
– Waste heat from hot exhaust gases
– Cooling water
– Hot liquor from equipments
Recovering waste heat provides attractive
opportunity for emission free and less costly
energy resource!
Copyright Forbes Marshall, 2009-
10
Condensate Recovery
To Drain!
Condensate contains 25% of
Total Energy Supplied – Using
this can make a difference
Copyright Forbes Marshall, 2009-
10
• Monetary Value
• Water Charges
• Effluent Restrictions
• No Boiler Derating
•Reduced water treatment costs
Every 6 deg increase in feed water temp from
return of hot condensate & recovery of flash
steam cuts your fuel bill by 1 %
As per our audit findings Average CR factor in
industry is 50-60%(energy recovered still less)
& very few recover Flash steam
Why Return Condensate?
Monetary values for
Condensate
Copyright Forbes Marshall, 2009-
10
Higher FW Temp. leads to fuel
savings
Copyright Forbes Marshall, 2009-
10
Copyright Forbes Marshall, 2009-
10
• Back Pressure on Steam Traps
•Flash Steam vented
•Drop in Condensate Temp
•Electrical cost of pumping – besides pump problems
•Too many components to maintain
Conventional Method - CR
Copyright Forbes Marshall, 2009-
10
Effective CR
FW Tank size matters….
Copyright Forbes Marshall, 2009-
10
Illustration:
Consider 4KL of condensate at 90 deg C held up in a tank. Now even a 10 deg. C drop here means a loss of 32KL of
FO or 91tons of coal annually!
Copyright Forbes Marshall, 2009-
10
Heat Content-Steam &
Condensate
Copyright Forbes Marshall, 2009-
10
Thermocompressor
Copyright Forbes Marshall, 2009-
10
Thermocompressor
Heat Recovery Potential
100 %
Energy
37%
utilize
d
63%
Waste
54.22%
Energy
Dye bath
Liquor
Condensate
Flash
Cooling Water
12.84%
14.85%
17.78%
Not considering losses the Process Heat Recovery in Dyeing m/c
Heat Recoveries - At a glance
Textile
Dye Liquor Heat Recovery
Cooling Water Recovery
CRP condensate Recovery
Stenter Exhaust Recovery
Vent Heat from Drum Washer
Brewery
Wort vapor Heat Recovery
Wort Cooling Water Recovery
Recovering heat from Bottle Washer drain
SEP & Oil Refi
Heat from waste water boiler
Recovering heat from Bleached Oil, Neutral Oil,
Crude Oil
Soap water to preheat hot water
Recovering heat from oil to generate hot water
and preheat miscella
Textiles
Brewery
SEP & Oil
Refinery
Dome Drain Heat Recovery
Hot water Heat Recovery
Blow through Steam Recovery
Tyre
Heat recovery from Dye liquor of Yarn Dyeing machine
At a large integrated textile mill
From drain to savings
Dye liquor at 90 oC when used for heating soft water for process lead to
annual savings of 21 lakhs with payback of just 2 months!!
CRP Hot Water Recovery
At a large integrated textile mill
From drain to savings
Recovering the CRP hot water to heat DM water lead to savings of 1.5 Crores
with payback period of 1 month!
Copyright Forbes Marshall, 2009-
10
Act fast and grow your Profits!!!
Fuel prices would
continue to spiral
upwards……. & so would
your losses!
Find out where you
stand.
Copyright Forbes Marshall, 2009-
10
Thank you
Efficient steam systems - Generation to WHR

More Related Content

What's hot

Thermal Power Plant Boiler Efficiency Improvement
Thermal Power Plant Boiler Efficiency ImprovementThermal Power Plant Boiler Efficiency Improvement
Thermal Power Plant Boiler Efficiency ImprovementAnkur Gaikwad
 
Fired Heater Operation and Trouble Shooting.pdf
Fired Heater  Operation and Trouble Shooting.pdfFired Heater  Operation and Trouble Shooting.pdf
Fired Heater Operation and Trouble Shooting.pdfMuhammadNaeem191352
 
Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1Manohar Tatwawadi
 
210 MW BHEL Turbine Cycle Heat Balance
210 MW BHEL Turbine Cycle Heat Balance210 MW BHEL Turbine Cycle Heat Balance
210 MW BHEL Turbine Cycle Heat BalanceManohar Tatwawadi
 
Performance calculation for feed water heater
Performance calculation  for feed water heaterPerformance calculation  for feed water heater
Performance calculation for feed water heaterSHIVAJI CHOUDHURY
 
Methanol Flowsheets - A Competitive Review
Methanol Flowsheets - A Competitive ReviewMethanol Flowsheets - A Competitive Review
Methanol Flowsheets - A Competitive ReviewGerard B. Hawkins
 
Magnetite layer
Magnetite layerMagnetite layer
Magnetite layerImran Khan
 
Fireball Formation and Combustion of Coal in a Boiler
Fireball Formation and Combustion of Coal in a BoilerFireball Formation and Combustion of Coal in a Boiler
Fireball Formation and Combustion of Coal in a BoilerZalak Shah
 
Unit lightup synchronisation & shutdown
Unit lightup synchronisation & shutdownUnit lightup synchronisation & shutdown
Unit lightup synchronisation & shutdownNitin Mahalle
 
Steam ejector working principle
Steam ejector working principleSteam ejector working principle
Steam ejector working principleKarnav Rana
 
210 mw turbine cycle heat rate
210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rateManohar Tatwawadi
 
Various ammonia technology
Various ammonia technologyVarious ammonia technology
Various ammonia technologyPrem Baboo
 
Oxygen treatment for super critical power plants
Oxygen treatment for super critical power plantsOxygen treatment for super critical power plants
Oxygen treatment for super critical power plantsSantosh Pardhi
 
Evaluation of a Boiler performance
Evaluation of a Boiler performanceEvaluation of a Boiler performance
Evaluation of a Boiler performanceHashim Hasnain Hadi
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticPichai Chaibamrung
 

What's hot (20)

Thermal Power Plant Boiler Efficiency Improvement
Thermal Power Plant Boiler Efficiency ImprovementThermal Power Plant Boiler Efficiency Improvement
Thermal Power Plant Boiler Efficiency Improvement
 
Fired Heater Operation and Trouble Shooting.pdf
Fired Heater  Operation and Trouble Shooting.pdfFired Heater  Operation and Trouble Shooting.pdf
Fired Heater Operation and Trouble Shooting.pdf
 
Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1
 
210 MW BHEL Turbine Cycle Heat Balance
210 MW BHEL Turbine Cycle Heat Balance210 MW BHEL Turbine Cycle Heat Balance
210 MW BHEL Turbine Cycle Heat Balance
 
Performance calculation for feed water heater
Performance calculation  for feed water heaterPerformance calculation  for feed water heater
Performance calculation for feed water heater
 
Methanol Flowsheets - A Competitive Review
Methanol Flowsheets - A Competitive ReviewMethanol Flowsheets - A Competitive Review
Methanol Flowsheets - A Competitive Review
 
Boiler Presentation
Boiler PresentationBoiler Presentation
Boiler Presentation
 
Magnetite layer
Magnetite layerMagnetite layer
Magnetite layer
 
Fireball Formation and Combustion of Coal in a Boiler
Fireball Formation and Combustion of Coal in a BoilerFireball Formation and Combustion of Coal in a Boiler
Fireball Formation and Combustion of Coal in a Boiler
 
Unit lightup synchronisation & shutdown
Unit lightup synchronisation & shutdownUnit lightup synchronisation & shutdown
Unit lightup synchronisation & shutdown
 
Steam ejector working principle
Steam ejector working principleSteam ejector working principle
Steam ejector working principle
 
210 mw turbine cycle heat rate
210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rate
 
Various ammonia technology
Various ammonia technologyVarious ammonia technology
Various ammonia technology
 
CFBC Boiler vs Pulverized Fired Boiler
CFBC Boiler vs Pulverized Fired BoilerCFBC Boiler vs Pulverized Fired Boiler
CFBC Boiler vs Pulverized Fired Boiler
 
Super critical boiler
Super critical boilerSuper critical boiler
Super critical boiler
 
Oxygen treatment for super critical power plants
Oxygen treatment for super critical power plantsOxygen treatment for super critical power plants
Oxygen treatment for super critical power plants
 
Evaluation of a Boiler performance
Evaluation of a Boiler performanceEvaluation of a Boiler performance
Evaluation of a Boiler performance
 
Cooling Water Treatment
Cooling Water TreatmentCooling Water Treatment
Cooling Water Treatment
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnostic
 
Boiler operation
Boiler operationBoiler operation
Boiler operation
 

Viewers also liked

applications overview
applications overviewapplications overview
applications overviewMark Jutila
 
AIR POLLUTION CONTROL Unit iv problem set
AIR POLLUTION CONTROL Unit iv problem setAIR POLLUTION CONTROL Unit iv problem set
AIR POLLUTION CONTROL Unit iv problem setDr. shrikant jahagirdar
 
Determining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler EfficiencyDetermining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler EfficiencyCleaver-Brooks
 
1.4 material and energy balance
1.4 material  and energy balance1.4 material  and energy balance
1.4 material and energy balancemichjosh
 

Viewers also liked (6)

applications overview
applications overviewapplications overview
applications overview
 
F05732228
F05732228F05732228
F05732228
 
AIR POLLUTION CONTROL Unit iv problem set
AIR POLLUTION CONTROL Unit iv problem setAIR POLLUTION CONTROL Unit iv problem set
AIR POLLUTION CONTROL Unit iv problem set
 
Patel dhaval
Patel dhaval Patel dhaval
Patel dhaval
 
Determining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler EfficiencyDetermining the Best Heat Recovery System to Maximize Boiler Efficiency
Determining the Best Heat Recovery System to Maximize Boiler Efficiency
 
1.4 material and energy balance
1.4 material  and energy balance1.4 material  and energy balance
1.4 material and energy balance
 

Similar to Efficient steam systems - Generation to WHR

005 energy saving tips
005 energy saving tips005 energy saving tips
005 energy saving tipsAnil Palamwar
 
Talk on energy efficiency by ajai arora
Talk on energy efficiency  by ajai aroraTalk on energy efficiency  by ajai arora
Talk on energy efficiency by ajai aroraRatan Kuber
 
Boiler and steam system seminar short version 05 29-13
Boiler and steam system seminar short version 05 29-13Boiler and steam system seminar short version 05 29-13
Boiler and steam system seminar short version 05 29-13Payden Sewell
 
Energy Conservation in Sugar Industry
Energy Conservation in Sugar IndustryEnergy Conservation in Sugar Industry
Energy Conservation in Sugar IndustryManohar Tatwawadi
 
54666070 kiln-operation
54666070 kiln-operation54666070 kiln-operation
54666070 kiln-operationDin Sokreach
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plantSHIVAJI CHOUDHURY
 
Boiler and steam system seminar 05 13-10(1)
Boiler and steam system seminar 05 13-10(1)Boiler and steam system seminar 05 13-10(1)
Boiler and steam system seminar 05 13-10(1)Payden Sewell
 
Kiln Training Module - kali.pptx
Kiln Training Module - kali.pptxKiln Training Module - kali.pptx
Kiln Training Module - kali.pptxJa Ti
 
Thermal Power Plants
Thermal Power PlantsThermal Power Plants
Thermal Power Plantspeeyush95
 
HEAT PUMP BY ER SOHEL R SHEIKH
HEAT PUMP BY ER SOHEL R SHEIKHHEAT PUMP BY ER SOHEL R SHEIKH
HEAT PUMP BY ER SOHEL R SHEIKHEr Sohel R Sheikh
 
Boiler Efficiency.pptx
Boiler Efficiency.pptxBoiler Efficiency.pptx
Boiler Efficiency.pptxSourav Bhunia
 
Theory and Operation - Secondary Reformers -
Theory and Operation - Secondary Reformers - Theory and Operation - Secondary Reformers -
Theory and Operation - Secondary Reformers - Gerard B. Hawkins
 
Training on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdfTraining on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdfMadan Karki
 
Energy audit boiler and steam lines
Energy audit  boiler and steam linesEnergy audit  boiler and steam lines
Energy audit boiler and steam linesRohil Kumar
 
Boiler thermalpowerplants 12898051220529-phpapp02
Boiler thermalpowerplants 12898051220529-phpapp02Boiler thermalpowerplants 12898051220529-phpapp02
Boiler thermalpowerplants 12898051220529-phpapp02akjshare
 
Energy audits in action
Energy audits in action Energy audits in action
Energy audits in action Lonnie Russell
 

Similar to Efficient steam systems - Generation to WHR (20)

005 energy saving tips
005 energy saving tips005 energy saving tips
005 energy saving tips
 
Talk on energy efficiency by ajai arora
Talk on energy efficiency  by ajai aroraTalk on energy efficiency  by ajai arora
Talk on energy efficiency by ajai arora
 
Boiler and steam system seminar short version 05 29-13
Boiler and steam system seminar short version 05 29-13Boiler and steam system seminar short version 05 29-13
Boiler and steam system seminar short version 05 29-13
 
Energy Conservation in Sugar Industry
Energy Conservation in Sugar IndustryEnergy Conservation in Sugar Industry
Energy Conservation in Sugar Industry
 
Energy audit of boiler
Energy audit of boilerEnergy audit of boiler
Energy audit of boiler
 
54666070 kiln-operation
54666070 kiln-operation54666070 kiln-operation
54666070 kiln-operation
 
Heat rate audit in thermal power plant
Heat rate audit in thermal power plantHeat rate audit in thermal power plant
Heat rate audit in thermal power plant
 
Energy conservation
Energy conservationEnergy conservation
Energy conservation
 
Boiler and steam system seminar 05 13-10(1)
Boiler and steam system seminar 05 13-10(1)Boiler and steam system seminar 05 13-10(1)
Boiler and steam system seminar 05 13-10(1)
 
200 mw FSSS
200 mw FSSS200 mw FSSS
200 mw FSSS
 
Kiln Training Module - kali.pptx
Kiln Training Module - kali.pptxKiln Training Module - kali.pptx
Kiln Training Module - kali.pptx
 
Thermal Power Plants
Thermal Power PlantsThermal Power Plants
Thermal Power Plants
 
4 ch1
4 ch14 ch1
4 ch1
 
HEAT PUMP BY ER SOHEL R SHEIKH
HEAT PUMP BY ER SOHEL R SHEIKHHEAT PUMP BY ER SOHEL R SHEIKH
HEAT PUMP BY ER SOHEL R SHEIKH
 
Boiler Efficiency.pptx
Boiler Efficiency.pptxBoiler Efficiency.pptx
Boiler Efficiency.pptx
 
Theory and Operation - Secondary Reformers -
Theory and Operation - Secondary Reformers - Theory and Operation - Secondary Reformers -
Theory and Operation - Secondary Reformers -
 
Training on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdfTraining on OJT of Boiler Operation00.pdf
Training on OJT of Boiler Operation00.pdf
 
Energy audit boiler and steam lines
Energy audit  boiler and steam linesEnergy audit  boiler and steam lines
Energy audit boiler and steam lines
 
Boiler thermalpowerplants 12898051220529-phpapp02
Boiler thermalpowerplants 12898051220529-phpapp02Boiler thermalpowerplants 12898051220529-phpapp02
Boiler thermalpowerplants 12898051220529-phpapp02
 
Energy audits in action
Energy audits in action Energy audits in action
Energy audits in action
 

More from National Productivity Council, Hyderabad, India

More from National Productivity Council, Hyderabad, India (16)

Boiler Water Treatment -
Boiler Water Treatment - Boiler Water Treatment -
Boiler Water Treatment -
 
Efficient Steam Systems -
Efficient Steam Systems -Efficient Steam Systems -
Efficient Steam Systems -
 
New Technologies in Process Heating
New Technologies in Process HeatingNew Technologies in Process Heating
New Technologies in Process Heating
 
Boiler Water Treatment for LP,MP and HP Boiler
Boiler Water Treatment for LP,MP and HP BoilerBoiler Water Treatment for LP,MP and HP Boiler
Boiler Water Treatment for LP,MP and HP Boiler
 
Case Studies on CFBC Boilers
Case Studies on CFBC BoilersCase Studies on CFBC Boilers
Case Studies on CFBC Boilers
 
Boiler Performance Monitoring
Boiler Performance MonitoringBoiler Performance Monitoring
Boiler Performance Monitoring
 
Boiler Superheater Design Modification
Boiler Superheater Design ModificationBoiler Superheater Design Modification
Boiler Superheater Design Modification
 
Developments in Industrial Boilers, WHR and Power Boilers
Developments in Industrial Boilers, WHR and Power BoilersDevelopments in Industrial Boilers, WHR and Power Boilers
Developments in Industrial Boilers, WHR and Power Boilers
 
Indigenization of Russian Make WHR by Vizag Steel
Indigenization of Russian Make WHR by Vizag SteelIndigenization of Russian Make WHR by Vizag Steel
Indigenization of Russian Make WHR by Vizag Steel
 
Online Efficiency Monitoring and Diagnostics in Coal Fired Boiler
Online Efficiency Monitoring and Diagnostics in Coal Fired BoilerOnline Efficiency Monitoring and Diagnostics in Coal Fired Boiler
Online Efficiency Monitoring and Diagnostics in Coal Fired Boiler
 
Boiler Maintenance & Safety
Boiler Maintenance & SafetyBoiler Maintenance & Safety
Boiler Maintenance & Safety
 
Optimizing Combustion using a Flue Gas Analyser
Optimizing Combustion using a Flue Gas AnalyserOptimizing Combustion using a Flue Gas Analyser
Optimizing Combustion using a Flue Gas Analyser
 
Presentation on CFBC Boilers
Presentation on CFBC BoilersPresentation on CFBC Boilers
Presentation on CFBC Boilers
 
Boiler Operation and Maintenance Experiences
Boiler Operation and Maintenance ExperiencesBoiler Operation and Maintenance Experiences
Boiler Operation and Maintenance Experiences
 
Safe Operation and Explosions in Boilers
Safe Operation and Explosions in BoilersSafe Operation and Explosions in Boilers
Safe Operation and Explosions in Boilers
 
Minimum Energy Performance Standards for Boilers in India
Minimum Energy Performance Standards for Boilers in IndiaMinimum Energy Performance Standards for Boilers in India
Minimum Energy Performance Standards for Boilers in India
 

Recently uploaded

power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and usesDevarapalliHaritha
 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacingjaychoudhary37
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZTE
 

Recently uploaded (20)

power system scada applications and uses
power system scada applications and usespower system scada applications and uses
power system scada applications and uses
 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacing
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
 

Efficient steam systems - Generation to WHR

  • 1. Efficient Steam Systems – Generation to Waste Heat Recovery Vizag – 8th December, 15
  • 2. 2
  • 3.
  • 4.
  • 5.
  • 6. Fuel Prices and Calorific Value Fuel Price (Rs./Kg) Calorific Value (Kcal/Kg) Furnace Oil 30 10200 HSD 52 10800 Natural Gas 40 8500 Coal 7 5500 Petcoke 9 8000 Rice Husk 3.5 3200 Briquette 5.5 4000
  • 7. Boiler Efficiency & Cost of Steam Fuel Avg S:F Avg Cost of Steam (Rs./Kg) Furnace Oil 12 2.25 HSD 13 4 Natural Gas 12 3.5 Coal 4.5 1.5 Petcoke 7 1.2 Rice Husk 3.2 1.2 Briquette 3 1.8
  • 8. Optimal Steam Generation System Meeting the process demands in a manner which is:
  • 9. Copyright Forbes Marshall, 2009- 10 Steam & Condensate Loop 100% fuel energy 80%steam 3% distribution losses 77% Process consumption 57% 20% Unburnt Stack Blowdown
  • 10. Steam Generation-Boiler House • Criteria for Selection of Boiler - Steam Demand : Peak /Average load - Steam Consumption pattern - Fuel selection w. r. t. availability, cost - Feasibility of COGEN Copyright Forbes Marshall, 2009- 10
  • 11. Copyright Forbes Marshall, 2009- 10 Cost of operation-Solid fuel
  • 12. Copyright Forbes Marshall, 2009- 10 Cost of operation–OilGas fuels
  • 13. Copyright Forbes Marshall, 2009- 10 Measured Losses
  • 14. Boiler Efficiency – Perception & Reality 86% 78% 74% 78% 70% 65% 60% 65% 70% 75% 80% 85% 90% Oil Solid Ideal Indirect Direct 8% 4% 8% 5%
  • 15. Copyright Forbes Marshall, 2009- 10 An increase of 2% efficiency in a 5 TPH boiler results in a saving of 53,200 liters of oil per year ! Factors affecting boiler efficiency
  • 16. Copyright Forbes Marshall, 2009- 10 Comparison of Efficiency Methods • Direct Efficiency • Useful Heat output / total heat input • Covers all losses • Simple to implement • Instrument accuracy has a significant affect on final efficiency • In Direct Efficiency • Efficiency = 100 – Losses • Considers Stack, Enthalpy, Radiation, Blowdown and unburnt losses • Gives detailed break up of losses • Not affected too much by instrument accuracy
  • 17. Copyright Forbes Marshall, 2009-10 Real life scenario • The measured efficiency of Process boilers varies a lot Min. Avg. Max. Direct Efficiency 61 % 72 % 82 % Indirect Efficiency 63 % 78 % 84 % • Efficiency is dynamic – It WILL keep on changing.
  • 18. Copyright Forbes Marshall, 2009- 10 What leads to variations • Air temperature • Fuel temperature • Fuel pressure • Moisture in fuel • Loading pattern • Changing calorific value of fuel • Use of multiple fuels
  • 19. Innovative Oil / Gas fired Boilers
  • 24. Manual Fired Boilers – Limitations !! • Indirect Efficiency Guaranteed 73 – 77% • Typical Direct Efficiency obtained 50-55% – More heat loss by radiation and convection during fuel feeding cycle resulting in lesser actual efficiency – Distribution of fuel on furnace grate is uneven leading to Empty pockets and fuel overloaded pockets possible – Operators tend to overfeed resulting in incomplete combustion • Manual fuel feeding is laborious and time consuming • The operator gets exposed to hot flames • These boilers can not be designed for higher pressure beyond 28 kg/cm2. 24
  • 25. Observations in Manual Fired Boilers • High stack temp of up to 249 Deg c @ 6 bar (g) causing heat carry over loss. • High O2 percentage - ~ up 10 (charged) -19 (discharged)% • Indirect efficiency – 65.3 % (@ 50% fix damper) Direct efficiency–50 % • Optimum Air : Fuel ratio is not maintained 25
  • 26. 26 Date Operating hrs Day wise Readings Steam generation (kg) Avg steam load (kg/h) Wood consumptio n (kg) S:F 13/10/10 12 4355 363 1607.4 2.70 15/10/10 10 4503 450.3 1441.8 3.12 16/10/10 4 2333 584 834 2.79 26/10/10 10 4906 490.6 1790 2.74 28/10/10 10 4414 441.4 1840 2.39 30/10/10 11 6561 597 1785 3.67 * 31/10/10 12 7883 657 2050 3.84 * 1/11/10 – IInd shift 5 1892 378.4 920 2.05 AVERAGE Steam : Fuel Ratio 2.85 S:F Ratio with Manual Fired boiler Gap Between Minimum and maximum S:F is 100% Gap between average and mimimum is 40%
  • 27. Stack , 26% Unburnt , 9.80% Enthalpy, 11% Radiation, 1.50% Ash, 1.75% Unaccounted, 0.25% Losses in Percentage Typical Break-up of Losses
  • 28. • Stack Loss – Frequent Opening & closing of door ID Fan damper position same for all stages of operation of boiler. • Unburnt Loss – Overfeeding of fuel resulting in low air for Burning which also leads to high amount of Unburnt generation. • Enthalpy Loss – Moisture in fuel & Air results in this loss. • Radiation Loss – Through Boiler Heating Surface areas – no Major control possible Deep Dive into the Losses…..
  • 29. Current Scenario • Variety of Boiler designs like Wet Back/Semi Wet Back & Dry Back • Converted external furnace boilers with deaerated capacity & with Big gap in efficiency • Quality of Accessories used on Solid fired boilers ???? • No Automation provided, hence total reliance on operator skills
  • 30.  O2 Levels – 9 – 11%  Excess Air - @70%  Furnace pressure – Between -5 to - 8 mmWC What should we AIM for ?
  • 31. Fuel Feeding practices •The boiler operator looks at steam pressure and does the fuel feeding accordingly. •Stoker mostly overfeeds fuel as per his convenience & Grate space. Irrespective of plant load, the grate is usually filled fully. This results in high un-burnts and stack loss Current Operating Practices in Manual Fired boilers
  • 32. Fuel Feeding practices • After feeding, the window is closed & fuel burns incompletely for some time leading to high unburnts as can be seen from the black chimney smoke colour during feeding • Thereafter, the fuel burns and is fed at a later stage by that time stack losses start to happen. Current Operating Practices in Manual Fired boilers
  • 33. Need Of The Hour based on Today’s Limitations in the Industry • To provide information & Alerts – to assist the boiler operator for efficient boiler operation. • To provide information to utility manager on – How the boiler was operated on Daily, weekly & monthly basis. • To generate MIS so as to follow better operating practices in boiler house for reduced fuel bills • To provide periodic maintenance alerts to enhance life of boiler & reduce on forced break downs.
  • 34. With IntellGeneral operating practice PHASE I: IMMEDIATELY AFTER FEEDING • Fuel is overfed • Bed not evenly spread • Black/dark grey smoke observed • High unburnt loss (High CO levels) • Stack O2 levels: 0-5% • Fuel feed optimised • Bed is evenly spread • Light grey/light Brown observed • Low CO levels • Stack O2 levels: 5-7% 4- 5 mi nu te 2- 3 mi nu te6% Stack O 6% Stack O
  • 35. With IntellGeneral operating practice PHASE II: AFTER FEEDING (contd.) • Large interval between fuel feeds • Uneven bed • Greyish-white smoke observed • Stack O2 levels: 5-10% • High feeding frequency • Light grey/light Brown smoke observed • Stack O2 levels: 6-10% 10- 14 mi nut es 8- 10 mi nu te6% Stack O 6% Stack O
  • 36. General operating practice With Intell PHASE III: AFTER FEEDING (contd.) • High feeding frequency • Light grey/light Brown smoke observed • Stack O2 levels: 8-12% 4- 5 mi nu te 2- 3 mi nu te6% Stack O 6% Stack O • Large interval between fuel feeds • Uneven bed • White smoke observed • High stack loss (High O2% levels) • Stack O2 levels: 8-18%
  • 37. Furnace Draft pressure • Boiler Furnace draft is maintained by guess-work and there is no measurement of it. Improper Boiler draft results in improper combustion and risk of back firing and increased unburnt loss. • Manual damper adjustments are based on expertise and vigilance Current Operating Practices in Manual Fired boilers
  • 38. So what can be done go close to level of comitted Indirect Efficiency levels?? • Continuous Monitoring of Boiler parameters • Generating Pop ups for corrective actions to be taken by boiler operator • Provide History & trends to utility manager for the boiler operations, which can suggest a necessary change in operations of boiler 38
  • 39. Intelligent Boiler 39 PLC Based HMI Display with POP UPS
  • 40. Facts & Figures!!• 2% decrease in O2 leads to 4% increase in Boiler Efficiency. • Every 6 deg C increase in Feed water temperature means 1% less fuel bill. • 20 Deg C variation in stack temperature from optimum value means 1% increased fuel consumption • Presence of 1% unburnt represents 2.5% excess fuel consumption. • 3mm soot deposition on tubes increases fuel consumption by 2% • Maintaining optimum water TDS avoids scaling, moisture carryover in steam & increase operating Efficiency.
  • 41. Pop ups 1. Feed fuel 2. Close the door 3. Open damper 4. Close damper 5. Clean the tubes 6. Reduce feed 7. Stir/poke the fuel bed 8. Check condensate recovery 9. Avoid sudden loading 10. Excess steam demand 11. Possible back fire 12. Improve water quality 13. Drain mobrey 14. Mobrey not drained 15. Clean the TDS sensor Safety Boiler Efficiency Good operating practices
  • 42. Feed fuel Condition: 1. Steam pressure is lesser than the set lower limit. 2. Gap between stack temperature & steam temperature is less than 50 C 3. Boiler door is closed
  • 43. Condition: Door open for more than 5 minutes. Close the door
  • 45. Intell – Management Tool!! • Min – Max values of important parameters can be seen on Daily/weekly/Monthly basis • History & Trends of two years of operation of boiler can be seen • Data on Number of alarms generated, addressed can be seen.
  • 46. Summary Screen • Gives a summary for current day and last day of the number of alarms occurred and how was the health associated to a particular parameter. • The heath number is an indication of the response time of the operator
  • 47.  Incorporate automated feeding for feeding fuel in Furnace  Feed only the required quantity of fuel  Ensure even spread of fuel over the bed  Modulation of air to fuel ratio  Control the air flow during operation cycle 47 How do we ACHIEVE this?
  • 48. Automation –Need of Hour!! Automation of – • Fuel feeding mechanism • Damper movement Objective..
  • 49. 49 Capacity – 1/2/3/4/4.5TPH Pressures – 10.54 / 14.5 / 17.5 kg/cm2(g) Fuel – Briquette/Coal/Wood Chips MS-HD DTB
  • 50.
  • 51. Copyright Forbes Marshall, 2009- 10 Online Efficiency Monitoring
  • 52. Copyright Forbes Marshall, 2009- 10 Online Efficiency Monitoring
  • 54. Generation Opportunity Description Generate steam at rated pressure Operating at lower pressure results in reduced output and carryover. Minimize excess air Reduces the amount of heat lost up the stack, allowing more of the fuel energy to be transferred to the steam Clean boiler heat transfer surface Promotes effective heat transfer from the combustion gases to the steam Maintain high feedwater temperature High Feedwater temperature drives out dissolved oxygen Size feedwater tank correctly As thumb rule, feedwater tank should be sized to be 1.5 times the peak steam demand Avoid oversizing the boiler Oversizing leads to frequent On-Off cycles in a boiler which lowers boiler efficiency Monitor Boiler Parameters Continuous monitoring of boiler parameters for optimized boiler efficiency Install heat recovery equipments (feedwater economizers/combustion air preheaters, blowdown heat recovery) Recovers available heat and transfers it back to the system by preheating feedwater or combustion air. Similarly apart from controlling blowdown, heat can be recovered from blowdown that is done.
  • 55. FM Solid Fuel Fired Boilers Hinged Doors for ease of maintenance
  • 56. FM Solid Fuel Fired Boilers Factory Insulation & Cladding
  • 57. FM Solid Fuel Fired Boilers Structurals & Platforms – Packaged Boiler Feed Water Pumps on Skid
  • 58. FM Solid Fuel Fired Boilers 600 kg/ hr Boiler (Dryback)
  • 59. FM Solid Fuel Fired Boilers Packaged Boiler)
  • 60. FM Solid Fuel Fired Boilers Twin Flue Boiler Ash Doors
  • 61. FM Solid Fuel Fired Boilers
  • 62. FM Solid Fuel Fired Boilers
  • 63. FM Solid Fuel Fired Boilers Individual Lines for Feed Water
  • 64. FM Solid Fuel Fired Boilers
  • 65. FM Solid Fuel Fired Boilers
  • 66. FM Solid Fuel Fired Boilers
  • 68. Schreiber Dynamix Dairy Baramati PO Date – 8th April 2013 Commissioning Date – 4th Dec 2013
  • 69.
  • 70.
  • 71.
  • 72. Copyright Forbes Marshall, 2009- 10 Steam Distribution • Pipe Sizing & Layout - Check adequacy & recommend improvement - Identify redundant piping & optimise layout for reduced losses. • Insulation - Check adequacy & estimate losses - Recommend improvements • Air Venting - Identify locations - Recommend right type, size & quantity • Metering - Identify locations - Recommend right type & size. • Trapping - Trap survey & recommendations - Estimation of loss through leaks - Recommendations of trap monitoring
  • 73. Steam pipe layout Copyright Forbes Marshall, 2009- 10 Steam CORRECT INCORRECT Steam
  • 74. Steam Mains –Condensate drain Copyright Forbes Marshall, 2009- 10 Condensate to Steam trap INCORRECT Flow Flow CORRECT Condensate to Steam trap Steam Pocket
  • 75. Importance of Correct Pipe Sizing Copyright Forbes Marshall, 2009- 10
  • 77. Need for Air Venting Copyright Forbes Marshall, 2009- 10
  • 78. Air Venting…. Copyright Forbes Marshall, 2009- 10
  • 79. Copyright Forbes Marshall, 2009- 10 Distribute at High Pressure This will have the following advantages: – Smaller bore steam mains needed so less heat (energy) loss due to smaller surface area. – Lower capital cost of steam mains, both materials such as pipes, flanges and support work and labour. – Lower capital cost of insulation (lagging). – Dryer steam at point of usage due to drying effect of pressure reduction taking place. – Boiler can be operated at higher pressure corresponding to its optimum operating condition, thereby operating more efficiently. – Thermal storage capacity of boiler increases, helping to cope more efficiently with fluctuating loads, & a reduced risk of priming & carryover
  • 80. Copyright Forbes Marshall, 2009- 10 Pressure Reducing Station
  • 81. Copyright Forbes Marshall, 2009- 10 Electro-pneumatic Temp control KE valve with PN actuator and EP5 Positioner SX65 Controller EL2270 Sensor Pneumatic power and electronic intelligence on a steam to liquid heat exchanger
  • 82. Copyright Forbes Marshall, 2009- 10 Trapping Issues Not Fit For Purpose Plant Start Up Not in service
  • 83. Copyright Forbes Marshall, 2009- 10 Commonly Prevailing • Failed Closed • Failed open • Not in service • Not fit for purpose • Installation
  • 84. Copyright Forbes Marshall, 2009- 10 The cost of Leaks??
  • 85. Cost of Steam Leaks…. Copyright Forbes Marshall, 2009- 10
  • 86. Copyright Forbes Marshall, 2009-10 Maintenance addresses only 20%! 20% Maintenance Procedures 40% Improper Selection/ Installation 20% Site Conditions 20% Manufacturing Defects
  • 87. Copyright Forbes Marshall, 2009- 10 Steam Trap Selection Criteria Steam Application Present type of Trap Benchmark Key Selection Factor Steam Main Line Drain Thermodynamic (TD) Thermodynamic (TD) Quick condensate removal Steam Tracing for product line Thermodynamic (TD) Balance Pressure Thermostatic (BPT) Energy Conservation Copper Tracing for instrument tracing No Traps Thermostatic (MST) Energy Conservation Process Heating Equipments TD / IB / FT Mechanical (Float Trap - FT) Process Efficiency and time Pump Casing Thermodynamic (TD) Thermodynamic (TD) Quick condensate removal
  • 88. Steam trap selection…. Copyright Forbes Marshall, 2009- 10
  • 89. Copyright Forbes Marshall, 2009- 10 Compact Steam Trapping Station Estimated weight : 13 kg 4.0 kg Assembly Parts & Labor 5 ea. 600# rated globe or gate valves 1 ea. Line strainer 8 ea. Sch 80 nipples 16 ea 1/2’’ welds 2 ealine “tee” 1 ea. Steam trap 1 ea. elbow CONVENTIONAL 720mm 160 mm 245mm
  • 90. Modern Process Trap Assembly TOFTIntegrated design for base and Cover PRODUCT MARKING Aesthetic Features
  • 91. Modern Float Trap Assembly TOFT TOFT VIEWS
  • 92. Copyright Forbes Marshall, 2009- 10 Glandless Piston Valves FEATURES – CLASS VI, BUBBLE TIGHT SHUT-OFF Ensures Positive Isolation – SS REINFORCED GRAPHITE SEALING RINGS Asbestos free Sealing rings, – FORGED CS BODY FOR SIZES UPTO 1 ½” Max. Pressure : 78 Kg/cm2 Max. Temperature : 427 °C
  • 94. Waste Heat Recovery • Important & unexplored area for reducing energy • Around 20 to 50% industrial energy input is lost as – Waste heat from hot exhaust gases – Cooling water – Hot liquor from equipments Recovering waste heat provides attractive opportunity for emission free and less costly energy resource!
  • 95. Copyright Forbes Marshall, 2009- 10 Condensate Recovery To Drain! Condensate contains 25% of Total Energy Supplied – Using this can make a difference
  • 96. Copyright Forbes Marshall, 2009- 10 • Monetary Value • Water Charges • Effluent Restrictions • No Boiler Derating •Reduced water treatment costs Every 6 deg increase in feed water temp from return of hot condensate & recovery of flash steam cuts your fuel bill by 1 % As per our audit findings Average CR factor in industry is 50-60%(energy recovered still less) & very few recover Flash steam Why Return Condensate?
  • 97. Monetary values for Condensate Copyright Forbes Marshall, 2009- 10
  • 98. Higher FW Temp. leads to fuel savings Copyright Forbes Marshall, 2009- 10
  • 99. Copyright Forbes Marshall, 2009- 10 • Back Pressure on Steam Traps •Flash Steam vented •Drop in Condensate Temp •Electrical cost of pumping – besides pump problems •Too many components to maintain Conventional Method - CR
  • 100. Copyright Forbes Marshall, 2009- 10 Effective CR
  • 101. FW Tank size matters…. Copyright Forbes Marshall, 2009- 10 Illustration: Consider 4KL of condensate at 90 deg C held up in a tank. Now even a 10 deg. C drop here means a loss of 32KL of FO or 91tons of coal annually!
  • 102. Copyright Forbes Marshall, 2009- 10 Heat Content-Steam & Condensate
  • 103. Copyright Forbes Marshall, 2009- 10 Thermocompressor
  • 104. Copyright Forbes Marshall, 2009- 10 Thermocompressor
  • 105. Heat Recovery Potential 100 % Energy 37% utilize d 63% Waste 54.22% Energy Dye bath Liquor Condensate Flash Cooling Water 12.84% 14.85% 17.78% Not considering losses the Process Heat Recovery in Dyeing m/c
  • 106. Heat Recoveries - At a glance Textile Dye Liquor Heat Recovery Cooling Water Recovery CRP condensate Recovery Stenter Exhaust Recovery Vent Heat from Drum Washer Brewery Wort vapor Heat Recovery Wort Cooling Water Recovery Recovering heat from Bottle Washer drain SEP & Oil Refi Heat from waste water boiler Recovering heat from Bleached Oil, Neutral Oil, Crude Oil Soap water to preheat hot water Recovering heat from oil to generate hot water and preheat miscella Textiles Brewery SEP & Oil Refinery Dome Drain Heat Recovery Hot water Heat Recovery Blow through Steam Recovery Tyre
  • 107. Heat recovery from Dye liquor of Yarn Dyeing machine At a large integrated textile mill From drain to savings Dye liquor at 90 oC when used for heating soft water for process lead to annual savings of 21 lakhs with payback of just 2 months!!
  • 108. CRP Hot Water Recovery At a large integrated textile mill From drain to savings Recovering the CRP hot water to heat DM water lead to savings of 1.5 Crores with payback period of 1 month!
  • 109. Copyright Forbes Marshall, 2009- 10 Act fast and grow your Profits!!! Fuel prices would continue to spiral upwards……. & so would your losses! Find out where you stand.
  • 110. Copyright Forbes Marshall, 2009- 10 Thank you