TABLE OF CONTENTS
Abstract
1.0 Introduction………………………………………………………………………………….....1
1.1 Aims and Objectives……………………………………………………………………............2
2.0 Precedent Studies…………………………………………………………………………......3
2.1 Lighting Precedent Study……………………………………………………………….......7-10
2.1.1 Solar Decathlon House, Texas
2.2 Acoustic Precedent Study…………………………………………………………………11-16
2.2.1 Yildiz Technical University
2.3 Conclusion………………………………………………………………………………………17
3.0 Research Methodology……………………………………………………………………...18
3.1 Methodology of Lighting Analysis…………………………………………………………….18
3.1.1 Description of Equipment…………………………………………………………….19
3.1.2 Data Collection Method…………………………………………………………...20-21
3.1.3 Lighting Analysis Calculation…………………………………………………......22-23
3.2 Methodology of Acoustic Analysis……………………………………………………………24
3.2.1 Description of Equipment…………………………………………………………24-25
3.1.2 Data Collection Method……………………………………………………………....26
3.1.3 Acoustic Analysis Calculation………………………………………………………..27
4.0 Site Study
4.1 Introduction……………………………………………………………………………………28
4.2 Reason for Selection…………………………………………………………………………29
4.3 Measured Drawings……………………………………………………………………....30-31
2
4.4 Existing Lighting Sources………………………………………………………………….32
4.5 Existing Acoustic Sources…………………………………………………………………33
4.6 Existing Materials on Site……………………………………………………………….....34
4.7 Zoning of Spaces…………………………………………………………………………...35
5.0 Lighting Analysis……………………………………………………………………….....36
5.1 Lighting Lux Readings………………………………………………………………...........36
5.1.1 Daytime Lux Readings…………………………………………………………......36
5.1.2 Night time Lux Readings……………………………………………………….......37
5.1.3 Observation and Discussion……………………………………………………38-39
5.2 Lux Contour Diagram……………………………………………………………………40-41
5.3 Analysis and Calculation……………………………………………………………………42.
5.3.1 Daylight Factor Calculation…………………………………………………………..42
5.3.2 Artificial Light Calculation…………………………………………………………….43
Zone 1: Sitting Area……………………………………………………………..43-45
Zone 2: Outdoor Sitting Area………………………………………………......46-49
Zone 3: Private Gathering Area………………………………………………..50-53
Zone 4: Storage Room 1……..…………………………………………………54-57
Zone 5: Coffee Counter……..…………………………………………………..58-61
Zone 6: Male Toilet ………….………………………………………………….62-65
Zone 7: Female Toilet………………………………………………………......61-63
Zone 8: Sitting Area 2……………………………………………………….... 64-66
Zone 9: Storage Room 2………………………………………………………..67-69
5.4Analysis and Evaluation…………………………………………………………………………70
6.0 Acoustic Analysis
6.1 Noise Sources………………………………………………………………………………...71
6.1.1 External Noise Sources …………………………………………………………….71
6.1.2 Internal Noise Sources………………………………………………………….72- 74
3
6.2 Acoustic Readings…………………………………………………………………………......75
6.2.1 Peak and Non-Peak Hours Readings………………………………………………....75
6.2.2 Observation and Discussion……………………………………………………….....76
6.3 Acoustic Ray Diagram………………………………………………………………………....77
6.4 Analysis and Calculation……………………………………………………………………....78
6.4.1 Equipment Sound Pressure Level……………………………………………….78-81
6.4.2 Sound Pressure Level Calculation……………………………………………....82-86
Zone 1: Sitting Area………………………………………………………………….82
Zone 2: Outdoor Sitting Area……………………………………………………….83
Zone 3: Private Gathering Area…………………………………………………....84.
Zone 4: Storage Room 1……..……………………………………………………..85
Zone 5: Coffee Counter……..………………………………………………………86
6.4.3 Spaces Acoustic Analysis………………………………………………………...87-91
6.4.4 Reverberation Time Calculation………………………………………………....92-99
6.4.5 Sound Reduction Index Calculation…………………………………………..100-102
6.5 Analysis and Evaluation…………………………………………………………………....104
8.0 References………………………………………………………………………………105-106
9.0 Appendix………………………………………………………………………………..107- 108
4
Abstract
This report contains the details of the study conducted on the Artisan Café with regards
to the lighting and acoustical performances. The report is broken down into two main segments
Lighting and Acoustics. Included are the technical data such as formulas, equations and
calculations that estimate both luminance levels as well as noise levels for both light and
acoustic. All orthographic drawings and diagrams were made with data collected from site. The
analysis diagrams were made with Autodesk Ecotect, an analysis software.
5
1.0 INTRODUCTION
Lighting is one of the major elements when it comes to architecture design, in interior as
well as exterior architecture. The texture, colors, solid volumes and enclosed spaces can only
be appreciated and enhanced fully when they are lit imaginatively. This project exposes and
introduces student to day lighting and artificial lighting requirements in a suggested space.
Acoustic design in architecture is an element which the control of sound in spaces is to be
concerned especially for enclosed spaces. The requirements vary in relation to different
functional spaces. It is essential to preserve and enhance the desired sound and to eliminate
noise and undesired sound. This project exposes and introduces students to acoustic design
and acoustical requirements in a suggested space.
In a group of six, we chose The Artisan Café, located at Petaling Jaya as our site study. We
have conducted several visits to our site to ensure the success of our project outcome.
Measured drawings, lightings and acoustics measurements as well as photographs have been
taken while we were on site. We have also done calculations and analysis to the results of our
observations and recordings.
6
1.1 Aims and objectives
The aim and objectives of this project is as follows:
- To understand the day lighting, lighting and acoustics characteristics
- To understand the lighting and acoustic requirements in a suggested place
- To determine the characteristics and function of day lighting, artificial lighting, sound and
acoustic, within the intended space.
- To critically report and analyze the space and suggest remedies to improvise the lighting
and acoustic qualities within the space.
This project also aims to provide a better understanding on the relationship between the type of
materials that are employed in terms of building materials as well as internal furnishings and
finishes as well as their impact on acoustical and lighting conditions in the building based on the
building’s functions. Understanding the volume and area of each functional space also helps in
determining the lighting requirements based on acoustical or lighting inadequacy that is
reflected in the data collection. Acknowledging adjacent spaces is also vital to address acoustic
concerns.
In terms of lighting, specifications of luminaries, height of each type of light as well as the
existence of fenestrations will help to understand the lighting conditions within each space.
Backed up with precedent studies, drawing comparison with our site study, our precedent
studies will aid in determining the different types of lighting and acoustic.
7
2.0 PRECEDENT STUDY
2.1 Lighting Precedent Study
Solar Decathlon House, Texas Usa.
Figure 2.1.1 : Image of Solar Decathlon House
The Solar Decathlon House (SDH) is an interdisciplinary competition project organized
by the U.S. Department of Energy where universities around the globe design, construct, and
operate fully solar-powered houses.
The Design
Glare is a major problem in these house whereby due to the floor to ceiling windows
surrounding the interior spaces. Based on the characteristics of the light coming through each
window in the living room and dining room a calculation of each type of windows and its daylight
permeability was done. After the test have been done the house is separated into three different
window types.
1. Daylighting Window - Only the sky is visible in the windowst is placed high on the wall and is
narrow with a horizontal aspect ratio. The sun’s path is never in the field of view.
8
2. View Window - Both the sky and the ground plane are visible through this window
3. Photovoltaic Panel Window - This window has embedded PV panels to capture energy and
block direct sun.
Diagram 2.1.1: Floor Plan of Solar Decathlon House
Materiality
The first step in determining the glare potential of Window 4 was to calculate the
reflectance values of all the different materials in the house as well as the materials of the
surrounding elements. These values can then be entered into simulation software like Ecotect
and Radiance. Reflectance of a material is determined by measuring luminance values.
Luminance is how much light your eye (or a sensor) sees after it’s reflected off of a surface.
The reflectance value was determined by using a luminance spot meter to measure the
luminance of a given surface compared with the luminance of known reference samples
(Kodak’s white and grey cards). When taking measurements, the luminous conditions should be
as diffuse as possible: no artificial lighting, no daylight at low/high incidence, etc.Using the
following formulas, the hemispherical-hemispherical reflectance (ρhh) was calculated for each of
the materials in and around the house. ρ1 = ρwhite * (L surface / L white) ρ2 = ρgrey * (L
surface / L grey) ρhh = ρ1 + ρ2 /2, with the luminance spot meter targeting the surface to be
9
measured, the surface reflectance value was measured (L surface). That value is then
compared with the same reading taken off the white card located in the same spot (L white).
Because we know the reflectance of the card (ρwhite), we can calculate the reflectance of the
material (ρ1). The procedure is repeated using the grey card, and then the average is
calculated. The RGB values of each surface were calculated approximately using Photoshop
and pictures from the interior of the room
Table 2.1.1 : Materiality Reflectance Table
The Light transmittance of a window by measuring luminance values. Illuminance is how
much light is coming from a light source. Transmittance is also known as the Visible Light
Transmittance (Tvis). To calculate the hemispherical-hemispherical transmittance (Thh) of the
windows, the ratio of illuminance of the light after passing through the glazing (lin) is compared
with light that bypasses the glazing (lout), where Thh = lin/lout. This measurement needs to be
performed under overcast sky conditions. Two luminance meters were used to take
measurements inside the room, with the window partially open so it was easy to measure the
10
light that had and had not passed through the glazing. In order to ensure accuracy, the
luminance meters were both calibrated and of the same brand and model. The measurements
were stopped at the same time and read simultaneously since the sky can vary its luminance
every second. Careful attention was paid not to cast any shadows over the luminance meters
Diagram 2.1.2 : Analysis Diagram
The house was then modeled in Ecotect, translating all the information captured on-site
into the model to make it as accurate as possible, including the furniture and the climatic
conditions. Within the model, camera views we set-up in the same position as on site. With the
Radiance Control Panel, the material surfaces were edited with the correct reflectance value, as
well as the correct transmittance taken on site. One challenge encountered was entering the
reflectance value of specula objects, such as the polished chrome metal refrigerator, into the 3D
model. Radiance cannot accurately represent specula materials that behave like mirrors, since
the reflectance will depend on the object being reflecting in the surface.
11
2.2 Acoustic Precedent Study
Yildiz Technical University
The auditorium hall of Yildiz Technical University (YTU University), The University took its final
name in 1992 as Yıldız Technical University located in the central campus is mainly used for
congresses, symposium, conferences and various other ceremonies. From time to time, it also
host events such as concerts. The hall was renovated in order to increase the audience
capacity and eliminate some of its disadvantages, while preserving its general architectural
characteristics.
Figure 2.2.1 : Yildiz Technical University Auditorium
Selection of Interior Surface Materials
The effects of materials with different acoustic absorption characteristics on the
acoustical environment are proportional to their surface areas. The surface materials chosen to
provide the optimum RT for the hall were also assessed with respect to their sizes. Cellular
materials for high frequency voices and vibratory panels for low frequency voices were used to
obtain a balanced frequency distribution.
The purpose of choosing the materials used are briefly explained below.
12
Floors
The audience platform was installed with 4mm thickness of felt underlying carper of
8mm thickness; upholstered chairs were used for the seating. In order to allow the sound to
reach the audience in the most efficient way, reflective materials are being used for the stage
and flooring.
Ceilings
8mm thick gypsum boards were used which covered the air conditioning installation. The
coffered ceiling was not fully covered with wooden material and was partly left as a hard
surface. In order to preserve the architectural elements of the structure itself, the height of the
audience platform has been increase Since the height of the space excluded this option from
consideration the vertical wooden panels placed around the stage were used to try to meet the
need for a reflective surface on and around the stage.
Walls
10mm thick wooden panels was considered appropriate in terms of acoustic parameters.
Some of the fiber glass-based absorbing materials was placed behind those panels in order to
maintain the balance between high and low frequency voices. Pipes and canals for the air
conditioning system were hidden by sloped panels covered with fabrics coated with gypsum,
especially at the interface of the back wall and the ceiling. The back wall of the hall was
furnished with 10 mm wooden panels, which were covered with thick fabrics in order to prevent
the generation of an echo.
13
Table 2.2.1:Surface materials in auditorium, their surface area and absorption coefficient (based
on Harris, 1994:Cavanaugh & Wilco, 1999)
Measurement and Analysis
During the revovation of the project, calculation and assessments were carried out on
the RT, acoustic level and speech inteligibility parameters. Since 2/3 of the auedience capacity
of the space was assumed to be utilized in the RT calculations, both empty and occupied seats
were included in the calculation at different absorption values. As speaking intended to be the
main use of the hall, the optimum RT range was determined on the basis of the space volume
and speech. The changes in RTs calculated by taking the interior surface materials into
consideration are shown in table 2. The Rts of the hall, which were measured before renovation,
and the RTs obtained from the calculation performed for the empty hall are also included in
table 2.3.1.
14
Table 2.2.2 RTs Calculation
Sound level measurement were carried out to locate the effects of the interior surface
cladding of the space on the BSL. In the unfurnished condition while the air conditioning was
operating, the measuremente above were acceptable at all noise frequencies. When the air
conditioning was switched off under the same condition, the results were only about 1 dB over
the acceptable values at frequencies of 1000 Hz, 2000 Hz and 4000 Hz. On the other hand, the
BSLs were always below the acceptable value in the furnished room, both before and after the
renovation.
Table 2.2.3 : Measured and acceptable BSLs (air conditioning)
Particially covering the ceiling with gypsum board and using wooden panels on the walls,
significant decays were obrained for RTs at low frequencies after the renovation.
15
Table 2.2.4: Measured, calculated and optimum RTs of YTU auditorium for speech activities.
Figure 2.2.2: Section of the YTU auditorium (after renovation)
16
Figure 2.2.3: Plan of YTU auditorium (after renovation)
17
2.3 Conclusion of Precedent Studies
2.3.1 Solar Decathlon House, Texas
Solar Decathlon house in Texas is perceived as building flooded with natural light during
daytime. The usage of floor to ceiling windows create a vast transparency between outdoor and
indoor space, hence allowing maximum permeability of light through it. The study done
throughout the day shows a mid range result whereby there are presence of glare during an
indefinite period of time and how the reflectance value of the materials effect the results of the
analysis. The amount of glare occurrence is being determined through a software whereby
projection of thermal quantities is being brought up and analyzed. Resulting from this a data
was brought forward and the amount of glare of each windows is calculated. Overall the result
shows an amount of unacceptable glare coming from the north portion of the window whereby
glazing is present. The result is then being translated and brought up to the users of the home.
The Precedent study has gave us an insight of how glazing can enhance and deteriorate the
lighting levels of the spaces and how materiality determines the lighting levels of spaces. The
importance of daylighting levels during designing is also implemented.
2.3.2 Yildiz Technical University
The acoustical properties of the hall have a definite improvement after the renovation
being done. The change in the acoustic environment of the hall can be clearly seen due to the
use of the different surface material after the renovation. In the study being done for the
auditorium the acoustical parameters were being done through the measurements and
assessments of the qualities of the surface materials used. Results generated shows the
dynamic improvement prior to renovation. The differences in terms of measurements according
to analysis done shows that the usage of materials can drastically effect the acoustic qualities of
the space. The need for acoustical study prior to construction and build helps designers and
engineers determined a space whereby it is conducive for its usage. Overall the precedent done
for this auditorium hall has help us gain an insight to the importance of acoustical study prior to
design and build as well as the dynamic impact of material usage can change the performance
of a building.
18
3.0 RESEARCH METHODOLOGY
3.1 Methodology of Lighting Analysis
3.1.1 Measuring Device: Digital Lux Meter
Figure 3.1.1 : digital lux meter
Digital Lux Meter is a lightweight electronic device used to measure illumination. This lux meter
is provided by Taylors University to aid us in recording data for the intensity of light.
General Specifications of Model LX-101
Display 13mm (0.5’’) LCD, 3 ½ digits, Max. indication 1999
Weight 160g/0.36lb (including battery)
Dimension Main instrument: 108 x 73 x 23mm
Measurement 0 to 50,000 Lux, 3 ranges
Power Supply 006P. DC 9V battery, MN 1604 (PP3) or
equivalent
Current Approx. 2.0mA (D.C)
Operating Temperature 0 to 50C (32 to 122F)
Over Input Display Indication of ‘’1’’
Zero adjustment Built in external zero adjust VR on front panel
Sensor The exclusive photo diode and colour correction
filter
Standard accessories 1 instruction manual
1 sensor probe
1 carrying case, CA-04
19
Electrical Specifications of Typical Lux Meter
Range Resolution Accuracy
0-1,999 Lux 1 Lux
±(5% + 2D)2,000-19,999 Lux 10 Lux
20,000-50,000 Lux 100 Lux
3.1.1.3 Application of Lux Meter
(a) The lux meter is switched on
(b) The lux meter is switched to a desired range (Resolution chosen : 1Lux)
(c) The sensor probe of the lux meter is held facing upwards t specific points
according
to our 2m gridded floor plan at 1m height.
(d) A reading is shown on the display screen of the lux meter
(e) The reading is recorded
(f) Steps (c), (d) and (e) are repeated by holding the lux meter at 1.5m height,
average
human eye level.
3.1.1.4 Limitation of Study
A lux meter is easy to use and handle. However, there may be some discrepancies in the
results when taking readings using a lux meter.
- Random Error
Human error has been cited as a contributing factor which might affect the readings taken by
the lux meter for instance; misreading the data shown on the lux meter. In addition, an
inconsistent holding position of the meter might/will affect the data collection.
Weather is an unpredictable cause of certain errors as well. For example, during specific data
collection time frames, the weather might change from extremely sunny to very cloudy/gloomy
20
and sunny again. Said change will greatly affect readings taken during that time. Additionally,
shadows casted on chosen area of recording will also have an impact on the Lux reading. Any
glare existent during the recordings will affect the internal lighting measurements.
Solutions: Repeat procedures and take several readings at the same height, then calculate the
average value which will be more precise.
- Systematic Error
The instrument might take a few seconds to stabilize the reading due to the sensitivity of the
sensor. Readings taken before the value stabilizes might give an inaccurate reading and
sometimes there could be a big gap between both readings of a particular position.
Solutions: Prepare a stand of respective height and leave it untouched until the measurement
stabilises before recording it.
3.1.2 Data Collection Method
Measurements are taken at two different times which is 12.00pm and 8pm, one with daylight
and the other without. In order to obtain reliable readings, the lux meter was placed at the same
height from the floor at each, 1m (waist height) and 1.5m (eye level). Each recording was done
by facing towards the similar direction, to synchronize the results. Plans with a perpendicular 2m
x 2m gridline were used as a reference guideline, whereby the intersections serve as data
recording points. In total there are ### points for lighting and acoustic data collection. Same
procedure are repeated for indoor and outdoor for both times.
21
Diagram3.1.1 : Standard height used to record Lux readings
Diagram 3.1.2 : 2m x 2m gridlines for recordings
22
3.1.3 Lighting Analysis Calculation
Lighting analysis is done by averaging the lux readings of demarcated 9zones based on
ms1525.
3.1.3.1 Daylight Factor, DF
daylight factor, DF = Einternal / Eexternalx 100
where,
Einternal = illuminance due to daylight at a point on the indoor’s working plane
Eexternal = direct sunlight
= 32,000 lx
For example, given that Einternal = 8000lx,
hence,
daylight factor, DF = Einternal / Eexternalx 100 8000/32000 x 100 = 25
3.1.3.2 Lumen Method
The Lumen Method is used to determine the number of lamps that should be installed for a
given area or room. In this case, fixtures are already installed, therefore, we are calculating the
total luminance of the space based on the number of fixtures and determine whether or not that
particular space has enough lighting fixtures.
the number of lamps is given by the formula:
N = E X A / F X UF X MF
where, N = number of lamps required
E = luminance level required (lux)
A = area at working plane height(m2
)
F = average luminous flux from each lamp (lm)
UF = utilization factor, an allowance for the light distribution of the luminaire and
the room surfaces
MF = maintenance factor, an allowance for the reduced light output because of
deterioration and dirt
23
Room Index, RI, is the ratio of room plan area to half the wall area between the working and
luminaire planes:
RI= L X W / Hm x (L +W)
where, L = length of room
W = width of room
Hm = mounting height, i.e. the vertical distance between the working plane and
the luminaries
24
3.2 Methodology of Acoustics Analysis
3.2.1 Measuring Device: Digital Sound Level Meter
Figure 3.2.1 : Digital Sound Level Meter
A sound level meter is an instrument used to measure sound pressure level, majorly used in
noise pollution studies for the quantification of different kinds of acoustics. A digital sound level
meter was provided by Taylors University. It was used to collect the acoustics readings at
Artisan Café.
3.2.1.1 General Specifications
Weight 489g
Dimension 254 x 68 x 45 mm
Measurement 30 – 130dB
Power Supply Alkaline/heavy duty DC 1.5V battery (UM3,AA) x
6pcs
Resolution 0.1dB
25
Frequency 31.5 to 8000Hz
Features
dB (A&C frequency weighting)
Time weighting ( Fast, Slow)
Peak Hold
Data Hold Record (Max., Min.)
3.2.1.2 Application of Digital Sound Level Meter
(a) ‘’on/off’’ button is pressed to switch on the device. Display of ‘’Auto Range’’, ‘’A frequency
weighing’’ and ‘’Fast time weighing’’ are selected and checked.
(b) the sound level meter is held at at 1m height, approximately at waist height.
(c) the device is held still and ensure the operator of the device do not produce any sound when
using device
(d) after all the above procedures are checked, then ‘’HOLD NEXT’’ button is pressed
(e) the reading is taken and shown on the display screen. The reading is recorded.
(f) Repeat steps (b) to (e) for the next recording position on the grid.
3.2.1.3 Limitation of Study
- Human Limitations
The digital sound level meter device is very sensitive to its surrounding, with a range of
recordings varying between data difference of approximately 0.2-0.3 of stabilisation. Therefore,
the data recorded is based on the time seconds when pressing the hold button.
Besides, when operating the sound level meter, the device might have been pointed towards
the incorrect path of sound source, causing the readings taken to be slightly imprecise.
- Sound source stability
during the peak hours, sound from all sources such as human activities, noise from music
26
speakers and coffee machines have had a great impact to the acoustic data recorded.
During the normal hours, external sounds form surrounding site varies from time to time which
affect the data collection as well.
3.1.2 Data Collection Method
Readings are recorded at two different times, which is 12pm and 8pm, non-peak and peak
hours respectively. In order to acquire the accurate reading, the sound level meter was placed
at the same height, 1.5m from floor level at every point. The operator of the device shall not talk
and make any noise in order to guarantee reliable sound readings. Each recording was done
facing the same direction, again to synchronize the results. Plans with a perpendicular 2m x 2m
gridline were used as reference guideline where the intersection points serve as the data
recording points. The radings are then tabulated. Same procedure is repeated for both indoor
and outdoor.
Diagram 3.2.1 : consistent height of reading 1.5m
27
3.1.3 Acoustic Analysis Calculation
acoustic analysis is one by categorizing the area into two different zones. The material used,
absorption coefficient, area, volume and calculation will be explained zone by zone.
3.2.3.1 Reverberation Time, RT
RT is the primary descriptor of an acoustic environment which is used to calculate the
reverberation time of an enclosed space.
Reverberation time, RT = 0.16 x space volume / total absorption
3.2.3.2 Sound Pressure Level, SPL
SPL is the average sound level at a space.
Sound Pressure Level, SPL = 10log10 (l/lo(ref) )
where, l = sound power/intensity (watts)
lo = reference power (1 x 10-12
watts)
3.2.3.2 Sound Reduction Index, SRI
SRI is used to calculate the transmission loss of materials.
Sound Reduction Index, SRI = 10log10(1/Tav)
where, Tav = (S1 x TC1 + S2 x TC2 +…..+ Sn x TCn ) / TOTAL SURFACE AREA
Sn= surface area of material n
TCn = Transmission coefficient of material
28
4.0 SITE STUDY
4.1 Introduction
Figure 4.1.1 : Interior views of Artisan Cafe
Case study : The Artisan Café
Type of space : Retro coffee shop
Address : Jalan 13/2, Seksyen 13, 46200 Petaling Jaya, Selangor, Malaysia
The artisan café is in the heart of Petaling Jaya. The place came to existence when the
branched company took over a portion of the old Cherry showroom and converted a warehouse
area into the cozy cafe you see today. There are fancy decorations and interesting innovative
design ideas to create a raw yet homely feel with wood, concrete and red clay brick. The light
fixtures found here are mostly made from recycled materials, for, steel pipes.
29
4.2 Reason for Selection
Artisan café has various issues involving lighting and acoustic which relates to the
analysis done for this project. In terms of acoustic issues, the site context of the café is mainly
an industrial area in Petaling Jaya. This affects the café due to the noise produced in the
neighboring context whereby car showrooms and service centers are neighboring the café. The
material choice and finishes used in the café also affect the reverberation.
Lighting design in artisan café also has its own issues. Due to the café concept to
provide a relaxing and subtle environment, the café has employed a lighting design which uses
dim lights and it proves to be insufficient. Light Glaring is also an issue faced by the café itself.
The front façade of the café is enveloped by glass where direct sunlight could penetrate
through, this is counteracted with an adjustable awning installed to provide shading and improve
the glare control of the space.
Figure4.1.2: Site Context of the Cafe
30
4.3 Measured Drawing
Figure 4.1.3 :Ground Floor Plan (N.T.S)
31
Figure 4.1.4 : Mezzanine Floor Plan(N.T.S)
Figure 4.1.5 : Sectional Drawing (N.T.S)
32
4.4 Existing Lighting Sources
Table 4.1.1 Artifial Lighting Sources
33
4.5 Existing Acoustic Sources
Table 4.1.2 Acoustic Sources
34
4.6 Existing Materials on Site
Table 4.1.3: Overall material table
Component Material Color Surface Finish Reflectance Value
(%)
Surface Area/
m2
WALL Brick Red Rough 10 20.5
Steel Black Gloss 5 15.45
Plaster White Matte 80 16.32
Plaster Black Matte 4 40
Glass Clear Gloss 8 31.68
ROOF Aluminum Silver Anodized 4 17.28
FLOOR Concrete Grey Matte 15 95.8
CEILING Plaster White Matte 80 95.8
FURNITURE
Timber Walnut Matte 10 32.5
MDF Black Matte 5 11.5
Ceramic White Gloss 65 15.5
Fabric Red Matte 12 20.5
35
4.7 Zoning Of Spaces
Figure 4.7.1 : Ground Floor Zoning Figure 4.7.2 : Mezzanine Floor Zoning
Zone 1 : Sitting Area Zone 7 : Toilet 2
Zone 2 :Outdoor Sitting Area Zone 8 : Seating Area 2
Zone 3 :Private Gathering Area Zone 9 : Storage Room 2
Zone 4 :Storage Room
Zone 5 :Coffee Counter
Zone 6 :Toilet
36
5.0 LIGHTING ANALYSIS
5.1 Lighting Lux Readings
5.1.1 Daytime Lux Readings
Light data (Lux)
Day time
Ground floor Mezzanine floor
Grid
Height
Grid
Height
Grid
Height
1m 1.5m 1m 1.5m 1m 1.5m
A4 926 572 D7 75 81 A8 53 69
B4 928 531 D8 47 62 A9 54 61
C4 468 28 D9 32 27 A10 41 58
D4 301 68 D10 7 11 B8 51 62
E4 208 45 E5 75 50 B9 51 66
F4 201 57 E6 89 75 B10 47 59
G4 211 78 E7 77 64 C9 20 31
H4 191 42 E8 42 65 C10 21 35
A5 30 56 E9 32 29 D9 22 35
A6 52 81 E10 8 12 E9 24 29
A7 70 97 F5 86 52 F9 20 31
B5 120 93 F9 47 65 F10 22 25
B6 102 104 F10 56 78 G6 21 32
B7 98 101 G5 81 55 G7 24 36
C5 104 83 G10 52 79 G8 21 29
C6 61 79 F6 81 70 G9 20 30
C7 57 77 F7 63 78 G10 21 32
A8 53 69 F8 64 79 H6 24 31
A9 11 34 G6 79 54 H7 38 41
A10 8 21 G7 87 113 H8 41 62
B8 63 82 G8 81 109 H9 54 60
B9 56 78 G9 62 80 H10 43 61
B10 17 11 F11 216 318 F11 29 32
C8 42 35 F12 210 301 F12 210 30
C9 41 31 G11 211 321 G11 211 321
C10 21 17 G12 206 311 G12 208 306
D5 108 82 H11 207 301 H11 216 318
D6 87 71 H12 218 321 H12 218 321
Table 5.1.1 Daytime Lux Readings
37
5.1.2 Nighttime Lux Readings
Lighting data (Lux)
Night time
Ground floor Mezzanine floor
Grid
Height
Grid
Height
Grid
Height
1M 1.5M 1M 1.5M 1M 1.5M
A4 24 44 D7 14 25 A8 10 15
B4 28 42 D8 12 22 A9 12 16
C4 31 42 D9 10 22 A10 12 17
D4 32 43 D10 12 24 B8 14 19
E4 34 43 E5 14 26 B9 15 22
F4 32 44 E6 16 28 B10 14 18
G4 31 42 E7 12 20 C9 11 20
H4 30 41 E8 10 20 C10 12 21
A5 13 19 E9 11 21 D9 19 21
A6 14 20 E10 12 23 E9 20 19
A7 15 23 F5 15 27 F9 18 21
B5 12 20 F9 12 21 F10 19 20
B6 14 20 F10 10 20 G6 11 20
B7 15 23 G5 14 25 G7 12 21
C5 11 22 G10 10 20 G8 10 20
C6 12 25 H5 15 27 G9 12 22
C7 17 27 H10 11 21 G10 10 21
A8 34 60 F6 18 26 H6 11 20
A9 37 65 F7 16 23 H7 10 20
A10 35 62 F8 14 24 H8 11 21
B8 35 64 G6 20 28 H9 10 20
B9 39 67 G7 15 21 H10 10 21
B10 34 63 G8 12 22 F11 10 21
C8 27 24 G9 10 23 F12 12 23
C9 15 20 H6 19 29 G11 10 21
C10 13 21 H7 14 21 G12 11 20
D5 20 37 H8 13 21 H11 129 175
D6 18 35 H9 11 22 H12 125 170
F11 10 21
F12 12 24
G11 10 22
G12 11 21
H11 127 172
H12 128 167
Table 5.1.2 Nightime Lux Readings
38
5.1.3 Observation and Discussion
Based on the lighting data table above, the following observations were noted along
with relevant discussions.
Observation 1:
Both light data collected during the day and night are lower than the recommended
lux level by MS 1525.
Discussion 1:
This is due to the owner trying to achieve the desired ambience and environment in
the café.
Observation 2:
Light data collected at a level of 1.5m above ground level are higher than the
readings taken at a level of 1m above ground
Discussion 2:
This is due to the proximity of the lux meter to the artificial light source. At a level of
1.5m, the lux meter is close to the source, thus it receives a higher lux reading as
compared to the reading taken at a level of 1m above ground.
Observation 3:
Lux readings in the toilet areas (ZONE 6 & ZONE 7) are relatively high as compared
to other spaces.
Discussion 3:
This is due to the ample amount of light sources in the relatively small area.
39
Figure 5.1.1: Artificial Light Diagram
The figure above illustrates the lighting rays of different artificial lighting used
in Artisan Cafe. The sitting area of the cafe has a really low light level due to the low
intensity lamps used. The sitting area uses wall lighting and pendant lighting as the
source of artificial lighting. This creates a really dark environment whereby it relates
to the theme of the cafe itself. There are no presence of down light or spotlights in
the sitting area of the cafe. However, the toilets are lighted up by LED spotlights,
used to increase the brightness of the space.
Figure 5.1.2: Natural Light Diagram
The figure above indicates the source of natural lighting throughout the
interior spaces of the cafe. Due to the facade of the building being glass, natural
lighting penetration is ample throughout the space. However due to glare the cafe
fitted blinds and retractable awnings on the windows and outdoor area solve this
matter.
40
5.2 Lux Contour Diagram
Diagram 5.2.1 Daylight Lux Contour Diagram
41
Diagram 5.2.2 Artificial Lux Contour Diagram
42
5.3 Analysis and Calculation
5.3.1 Daylight Factor Calculation
Time/
Date/ Sky
Condition
Zone
Daylight
Level in
Malaysia
Eo (lux)
Average
Lux
reading
Ei (lux)
Daylight
Factor, DF
DF = (Ei / Eo)
X 100%
11th
April
2014
12.30 PM
Sunny
Zone 1
32000
75.92
DF = (Ei / Eo) X
100%
DF = (75.92 /
32000) X100%
0.24%
Zone 2
303.44
DF = (Ei / Eo) X
100%
DF = (303.44 /
32000) X100%
0.95%
Zone 3
80.42
DF = (Ei / Eo) X
100%
DF = (80.42 /
32000) X100%
0.25%
43
5.3.2 Artificial Light Calculation
Zone 1: Sitting Area
Figure 5.3.1 Sitting Area Light Indicator Plan
Table 5.3.1 Lighting Specifications
44
Table 5.3.2 : Zone 1 Material Table
Component Material Colour Surface
Finish
Reflectance
Value (%)
Surface
Area/ m2
WALL Brick Red Rough 10 20.5
Plaster White Matte 80 16.32
Plaster Black Matte 4 40
Glass Clear Gloss 8 31.68
FLOOR Concrete Grey Matte 15 95.8
CEILING Plaster White Matte 80 95.8
FURNITURE
Timber Walnut Matte 10 15.4
Ceramic White Gloss 65 5.6
Fabric Red Matte 12 20.9
45
A B C
Width of Room 5.7 5.7 5.4 2.3
Length of room 8 8 6 3.8
Dimension of Room ( L x W ) 45.6 45.6 32.4 8.74
Total floor Area / A 86.74
Type of lighting fixture Vintage Edison Vintage
Edison
LED
Spotlight
Number of lighting fixture / N 3 2 3 1
Lumen of lighting fixture / F (lux) 310 310 310 325
Height of luminaire (m) 1.7 1.7 1.9 2.3
Height of work level (m) 0.8 0.8 0.8 0.8
Mounting height / H (m) 1.1 0.9 0.9 1.5
Assumption of Reflectance value Wall 0.8/Ceiling 0.8/Floor 0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
3.03 3.70 3.16 0.96
Utilization Factor / UF 0.54 0.54 0.54 0.43
Based on given utilization factor table
Maintenance Factor / MF 0.8 0.8 0.8 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
4.63 3.09 4.63 1.29
Total Illuminance 13.64
Table 5.3.4 : Zone 1 Calculation Table
46
Zone 2: Outdoor Sitting Area
Figure 5.3.2: Outdoor Sitting Area Light Indicator Plan
Table 5.3.4 : Lighting Specifications
47
Table 5.3.5 : Zone 2 Material Table
Component Material Colour Surface
Finish
Reflectance
Value (%)
Surface
Area/m2
WALL Glass Clear Gloss 8 47.83
Aluminu
m
Silver Anodiz
ed
55 24.3
Plaster White Matte 80 24.32
FLOOR Brick Red Matte 10 114
CEILING Canvas Black Matte 4 50.4
Plaster Black Matte 4 55.6
FURNITURE
Timber Walnut Matte 10 43.6
48
Width of Room 4
Length of room 15
Dimension of Room ( L x W ) 60
Total floor Area / A 60
Type of lighting fixture LED Spotlight
Number of lighting fixture / N 6
Lumen of lighting fixture / F (lux) 325
Height of luminaire (m) 2.8
Height of work level (m) 0.8
Mounting height / H (m) 2
Assumption of Reflectance value Wall0.5/Ceiling0.5/Floor0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
1.58
Utilization Factor / UF 0.43
Based on given utilization factor table
Maintenance Factor / MF 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
11.18
Total Illuminance 11.18
Table 5.3.6 : Zone 2 Calculation Table
49
Zone 3: Private Gathering Area
Figure 5.3.4: Private Gathering Area Light Indicator Plan
Table 5.3.7 : Lighting Specifications
50
Table 5.3.8 : Zone 3 Material Table
Component Material Colour Surfa
ce
Finish
Reflectanc
e Value
(%)
Surface
Area/
m2
WALL Glass Clear Gloss 8 12.7
Aluminum Silver Anodi
zed
55 11.6
Plaster Black Matte 4 17.28
Steel Black Gloss 5 5.43
FLOOR Concrete Grey Matte 15 26.4
CEILING Plaster Black Matte 80 26.4
FURNITURE
Timber Walnut Matte 10 22.4
51
A B
Width of Room 4.9 4.9
Length of room 5.4 5.4
Dimension of Room ( L x W ) 26.46 26.46
Total floor Area / A 26.46 26.46
Type of lighting fixture Vintage Edison Philips Compact
Halogen Bulb
Number of lighting fixture / N 4 3
Lumen of lighting fixture / F (lux) 325 900
Height of luminaire (m) 1.9 3
Height of work level (m) 0.8 0.8
Mounting height / H (m) 1.1 2.2
Assumption of Reflectance value Wall0.8/Ceiling0.5/Floor0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
2.34 1.17
Utilization Factor / UF 0.55 0.47
Based on given utilization factor table
Maintenance Factor / MF 0.8 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
21.62 38.37
Total Illuminance 59.98
Table 5.3.9 : Zone 3 Calculation Table
52
Zone 4: Storage Room 1
Figure 5.3.5: Storage Room Light Indicator Plan
Table 5.3.9 : Lighting Specifications
53
Table 5.3.10 : Zone 4 Material Table
Component Material Colour Surface
Finish
Reflectan
ce Value
(%)
Surface
Area/
m2
WALL Glass Clear Gloss 8 23.2
Plaster Black Matte 4 40.96
FLOOR Concrete Grey Matte 15 13.44
CEILING AC sheet Black Matte 4 13.44
FURNITURE
Timber Walnut Matte 10 11.1
54
Width of Room 2.84
Length of room 4.8
Dimension of Room ( L x W ) 13.68
Total floor Area / A 13.68
Type of lighting fixture Fluorescent Light
Number of lighting fixture / N 2
Lumen of lighting fixture / F (lux) 1200
Height of luminaire (m) 1.9
Height of work level (m) 0.8
Mounting height / H (m) 1.1
Assumption of Reflectance value Wall0.3/Ceiling0.3/Floor0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
1.63
Utilization Factor / UF 0.4
Based on given utilization factor table
Maintenance Factor / MF 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
56.14
Total Illuminance 56.14
Table 5.3.11 : Zone 4 Calculation Table
55
Zone 5: Coffee Counter
Figure 5.3.5: Coffee Counter Light Indicator Plan
Table 5.3.12 : Lighting Specifications
56
Table 5.3.13 : Zone 5 Material Table
Component Material Colour Surfa
ce
Finish
Reflectanc
e Value
(%)
Surface
Area/
m2
WALL Glass Clear Gloss 8 12.7
Plaster White Matte 80 17.28
FLOOR Concrete Grey Matte 15 26.4
CEILING Metal Black Matte 4 26.4
FURNITURE
Timber Walnut Matte 10 21.6
MDF Black Matte 5 11.54
57
Width of Room 3.8
Length of room 6.1
Dimension of Room ( L x W ) 23.18
Total floor Area / A 23.18
Type of lighting fixture LED Spotlight
Number of lighting fixture / N 14
Lumen of lighting fixture / F (lux) 325
Height of luminaire (m) 2.8
Height of work level (m) 0.8
Mounting height / H (m) 2
Assumption of Reflectance value Wall0.8/Ceiling0.3/Floor0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
1.17
Utilization Factor / UF 0.38
Based on given utilization factor table
Maintenance Factor / MF 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
59.67
Total Illuminance 59.67
Table 5.3.14 : Zone 5 Calculation Table
58
Zone 6: Male Toilet
Figure 5.3.6: Male toilet Light Indicator Plan
Table 5.3.15 : Lighting Specifications
59
Table 5.3.16 : Zone 6 Material Table
Component Material Colour Surface
Finish
Reflectan
ce Value
(%)
Surface
Area/
m2
WALL Ceramic White Gloss 65 12.8
Plaster Black Matte 4 40.64
FLOOR Concrete Grey Matte 15 13.4
CEILING AC sheet Black Matte 4 13.44
FURNITURE
Mirror Reflectiv
e
Gloss 100 21.4
Porcelain White Gloss 75 11.1
60
Width of Room 4
Length of room 3.35
Dimension of Room ( L x W ) 13.4
Total floor Area / A 13.4
Type of lighting fixture LED Bulb (Recessed)
Number of lighting fixture / N 6
Lumen of lighting fixture / F (lux) 380
Height of luminaire (m) 1.6
Height of work level (m) 0.8
Mounting height / H (m) 0.8
Assumption of Reflectance value Wall0.5/Ceiling0.3/Floor0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
2.28
Utilization Factor / UF 0.44
Based on given utilization factor table
Maintenance Factor / MF 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
59.89
Total Illuminance 59.89
Table 5.3.17 : Zone 6 Calculation Table
61
Zone 7: Female Toilet
Figure 5.3.7: Female toilet Light Indicator Plan
Table 5.3.18 : Lighting Specifications
62
Table 5.3.19 : Zone 7 Material Table
Component Material Colour Surface
Finish
Reflectan
ce Value
(%)
Surface
Area/
m2
WALL Ceramic White Gloss 65 12.8
Plaster Black Matte 4 40.64
FLOOR Concrete Grey Matte 15 13.4
CEILING AC sheet Black Matte 4 13.44
FURNITURE
Mirror Reflectiv
e
Gloss 100 13.6
Porcelain White Gloss 75 5.2
63
Width of Room 4
Length of room 3.35
Dimension of Room ( L x W ) 13.4
Total floor Area / A 13.4
Type of lighting fixture LED Bulb (Recessed)
Number of lighting fixture / N 6
Lumen of lighting fixture / F (lux) 380
Height of luminaire (m) 1.7
Height of work level (m) 0.8
Mounting height / H (m) 0.9
Assumption of Reflectance value Wall0.7/Ceiling0.5/Floor0.2
Room Index / RI (K)
RI= L x W
( L + W ) x H
2.03
Utilization Factor / UF 0.53
Based on given utilization factor table
Maintenance Factor / MF 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
72.14
Total Illuminance 72.14
Table 5.3.20 : Zone 7 Calculation Table
64
Zone 8: Sitting Area 2
Figure 5.3.8: Sitting Area 2 Light Indicator Plan
Table 5.3.21 : Lighting Specifications
65
Table 5.3.22 : Zone 8 Material Table
Component Material Colour Surface
Finish
Reflectan
ce Value
(%)
Surface
Area/
m2
WALL Plaster White Matte 80 55.4
Plaster Black Matte 4 62.4
Steel Black Matte 4 34.5
Brick Red Rough 10 67.4
FLOOR Fiber
board
Grey Matte 15 13.4
CEILING Plaster White Matte 80 13.4
FURNITURE
Timber Walnut Matte 10 32.3
Fabric Red Matte 12 20.1
66
A B
Width of Room 3.4 2.85
Length of room 9.15 4.8
Dimension of Room ( L x W ) 31.11 213.68
Total floor Area / A 31.11 213.68
Type of lighting fixture Bulbrite 100W
Glove Bulb
Bulbrite 100W
Glove Bulb
Number of lighting fixture / N 5 3
Lumen of lighting fixture / F (lux) 580 580
Height of luminaire (m) 1.8 1.8
Height of work level (m) 0.8 0.8
Mounting height / H (m) 1 1
Assumption of Reflectance value Wall0.8/Ceiling0.8/Floor0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
2.48 1.79
Utilization Factor / UF 0.53 0.5
Based on given utilization factor table
Maintenance Factor / MF 0.8 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
39.52 50.88
Total Illuminance 90.40
Table 5.3.23 : Zone 8 Calculation Table
67
Zone 9: Storage Area 2
Figure 5.3.9: Storage Room 2 Light Indicator Plan
Table 5.3.24 : Lighting Specifications
68
Table 5.3.25 : Zone 9 Material Table
Component Material Colour Surface
Finish
Reflectan
ce Value
(%)
Surface
Area/
m2
WALL Plaster White Matte 80 4.8
Plaster Black Matte 4 2.3
Steel Black Matte 4 4.5
Brick Red Rough 10 5.6
FLOOR Fiber
board
Grey Matte 15 13.4
CEILING Plaster White Matte 80 13.4
FURNITURE
Timber Walnut Matte 10 7.9
Fabric Red Matte 12 3.0
69
A B
Width of Room 2.85 2.85
Length of room 4.8 4.8
Dimension of Room ( L x W ) 13.68 13.68
Total floor Area / A 13.68 13.68
Type of lighting fixture Vintage Edison Halogen bulb
Number of lighting fixture / N 2 3
Lumen of lighting fixture / F (lux) 310 900
Height of luminaire (m) 1.6 1.6
Height of work level (m) 0.8 0.8
Mounting height / H (m) 0.8 0.8
Assumption of Reflectance value Wall0.8/Ceiling0.8/Floor0.1
Room Index / RI (K)
RI= L x W
( L + W ) x H
2.24 2.24
Utilization Factor / UF 0.51 0.51
Based on given utilization factor table
Maintenance Factor / MF 0.8 0.8
Standard Illuminance (lux)
Iluminance level (lux)
E = N x F x UF x MF
A
18.49 53.68
Total Illuminance 72.18
Table 5.3.26 : Zone 9 Calculation Table
70
5.4 Analysis and Evaluation
Lighting is important within restaurants and cafes, especially feature lighting
that creates ambience and mood. The different types of lighting fixtures found inside
the Artisan Cafe offers different illumination levels. From our observation on site,
pendant lighting is the dominant type of lighting fixture at the first floor of the café. It
is used mainly to illuminate the tables at the main and private seating area, as well
as the seating areas at the mezzanine floor. However at the coffee counter area,
track spotlights are being used instead, to illuminate the menus hanged above the
counters. Unlike pendant lighting that uniformly distributes illumination, spotlighting
only illuminates the spot at which it is directed. Spaces in which these lights are not
pointed at are usually inadequately lit up.
Based on our data collection, the space inside the café is considered to be
rather dark during the day, despite having large glass entrance. It is mainly due to
the large black canvas roof covering the outdoor seating area, and most of the
interior pendant lights are switched off during the day. Referring to the precedent
study on lighting analysis, the Solar Decathlon House utilizes daylighting and
countermeasures against glare from sunlight. This predicts the result of using
daylighting and how it affects the ambience of a space.
Most of the lux readings on our site are below the lux requirements for each
space during daytime due to the interior lights not being utilized. Even during the
nighttime with all the lights turned on, the readings are still below lux requirements.
However, it is the intention for the café to have a somewhat dim ambience to create
that cool and cozy environment in the café. Natural lighting is only available to
penetrate inside the building to the main sitting area and the private sitting area, due
to both areas are the closest to the glass walls of the entrance.
In conclusion, it may be the designer to have the café to be dimly lit to
achieve a certain character and ambience however, the requirements set by MS
1525 must be taken into consideration when it comes lighting design not only to
achieve the desired atmosphere but as well as visual comfort.
71
6.0 ACOUSTIC ANALYSIS
6.1 Noise Sources
6.1.1 External Noise Sources
Figure 6.1.1: Location of Site in relation to main road
The site is facing a trunk road Jalan 13/2. The road is moderately busy during
non-peak hours and peak hours. The main outdoor noise sources are coming from
the construction site located opposite the site and beside the site. Due to the
typology of the site being and industrial zone, factory activities is also one of the
contributors of outdoor noises. Apart from these noises vehicular noise present
nearby the construction zones also create an impact towards the cafe.
72
6.1.2 Internal noise sources
Air Circulators
Figure 6.1.2: Placement of Air Circulators
Air conditioners are placed in the interior space of the cafe as a form of
artificial ventilation. Fans are also present in the space to compliment the usage of
mechanical ventilation. The noise produced by these equipment has a low effect
towards the acoustic values due to the nature of the site as a cafe whereby the noise
frequency is outnumbered by the human activity. However when the cafe closes a
certain acoustical value can be captured in the space itself.
73
Human Activity
Figure 6.1.3: Human activity points
Concentration of human activities in the cafe varies throughout the day.
During peak hour, the amount of human activities increases therefore there is a jump
in reading. Customers having discussion and chats are the main factor. However the
sound of coffee preparation is also a major acoustic value contributor due to the
nature of the coffee machine located at Zone 5.
74
Audio Equipment
Figure 6.1.4: Position of Speakers
Speakers are located throughout the cafe. The speakers are turned on in a
low volume to create a soothing atmosphere while maintaining a conversation free
zone. The music played throughout the day are mellow and slow therefore there are
really little contribution from the speakers. Speakers also helps create a
reverberation from the sound generated from the human activity and neutralizes the
impact from it.
75
6.2 Acoustic Readings
Table 6.2.1 Peak and Non - Peak Hours Readings
Acoustic data
Day time
Ground floor Mezzanine floor
Grid
Acoustic
Grid
Acoustic
Grid
Acoustic
Peak Non-peak Peak Non-peak Peak Non-peak
A4 79 67 D7 75 62 A8 57 31
B4 76 65 D8 73 63 A9 60 32
C4 80 63 D9 71 61 A10 58 43
D4 85 64 D10 77 68 B8 57 33
E4 86 63 E5 80 69 B9 59 32
F4 77 62 E6 73 63 B10 60 34
G4 80 64 E7 73 63 C9 75 61
H4 78 65 E8 76 65 C10 79 65
A5 77 55 E9 73 62 D9 77 63
A6 70 57 E10 80 70 E9 75 63
A7 66 43 F5 64 53 F9 77 63
B5 73 54 F9 78 65 F10 77 70
B6 72 58 F10 77 70 G6 77 66
B7 69 40 G5 63 42 G7 75 61
C5 74 55 G10 82 70 G8 74 61
C6 74 53 H5 64 49 G9 71 60
C7 73 51 H10 86 74 G10 68 58
A8 59 32 F6 70 63 H6 74 63
A9 66 34 F7 80 71 H7 74 62
A10 59 33 F8 82 70 H8 73 63
B8 57 32 G6 79 65 H9 71 60
B9 59 34 G7 85 73 H10 68 59
B10 57 32 G8 85 71 F11 66 54
C8 73 67 G9 86 71 F12 68 58
C9 74 65 H6 76 63 G11 65 53
C10 74 63 H7 84 74 G12 67 56
D5 77 60 H8 84 72 H11 68 58
D6 75 63 H9 83 75 H12 69 59
F11 66 57
F12 67 57
G11 68 56
G12 65 56
H11 65 56
H12 64 57
76
6.2 Observation and Discussion
Based on the noise level data table above, the following observations were noted
along with relevant discussions.
Observation 1:
The average noise level data collected during peak hours are higher compared to the
data collected during non-peak hours.
Discussion 1:
This is due to the larger number of occupants in the building during peak hours that
contributes to the increase of noise levels. The coffee grinders are also utilized from
time to time, which may affect the noise level.
Observation 2:
The noise reading levels during peak and non-peak in the main and private sitting
areas are averagely similar.
Discussion 2:
This is due to the areas sharing the same open space, only divided by a partition.
Observation 3:
The average reading levels during peak and non-peak hours at the coffee counter
are the highest compared to other zones.
Discussion 3:
This is due to the utilization of coffee grinders which affects the noise level readings.
77
6.3 Acoustic Ray Diagrams
Figure 6.3.1: Acoustic Ray Diagram
78
6.4 Analysis and Calculation
6.4.1 Equipment Sound Pressure Level
Calculation for speakers
Sound pressure level (SPL) = 10log (I/Iref)
IhereI = sound power (watt)
Iref = reference power (10-12
)
Number of speakers in Artisan coffee HQ (indoor) = 5
Number of Speakers in Artisan Coffee HQ (outdoor) = 2
One speaker produces approximately 80 dB
Therefore,
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 80/10 X 10-12
I= 108
X 10-12
I= 10-4
Total number of speakers indoor = 5
Total intensity = 5 x 10-4
Therefore, combined SPL indoor = 10log (I / Iref)
= 10log (5 x 10-4
/ 1 X 10-12
)
= 86.99 dB
Therefore, combined SPL outdoor = 10log (I / Iref)
= 10log (2 x 10-4
/ 1 X 10-12
)
= 83.01 dB
79
Calculation for Air conditioner
Number of Air Conditioner in Artisan Coffee HQ = 6
One Air Conditioner produces approximately 40 dB
Therefore,
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 40/10
X 10-12
I= 104
X 10-12
I= 10-8
Total number of air conditioner= 6
Total intensity = 6 x 10-8
Therefore, combined SPL = 10log (I / Iref)
= 10log (6 x 10-8
/ 1 X 10-12
)
= 47.78 dB
80
Calculation for ceiling fan
Number of ceiling fan in Artisan coffee HQ (indoor) = 1
Number of ceiling fan in Artisan Coffee HQ (outdoor) = 2
One ceiling fan produces approximately 50 dB
Therefore,
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 50/10
X 10-12
I= 105
X 10-12
I= 10-7
Total number of ceiling fan indoor = 1
Total number of ceiling fan outdoor = 2
Total intensity = 1 x 10-7
Therefore, combined SPL indoor = 10log (I / Iref)
= 10log (1 x 10-7
/ 1 X 10-12
)
= 50 dB
Therefore, combined SPL outdoor = 10log (I / Iref)
= 10log (2 x 10-4
/ 1 X 10-12
)
= 53.01 dB
Calculation for coffee maker
Number of coffee maker in Artisan Coffee HQ = 1
One coffee maker produces approximately 70 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
81
I= 10 70/10
X 10-12
I= 107
X 10-12
I= 10-5
Calculation for exhaust fan
Number of exhaust fan in Artisan Coffee HQ = 4
One exhaust fan produces approximately 60 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 60/10
X 10-12
I= 106
X 10-12
I= 10-6
Therefore, combined SPL = 10log (I / Iref)
= 10log (4 x 10-6
/ 1 X 10-12
)
= 66.02 dB
zone 3 =1 speaker 1 aircon
zone 4 = 1 aircon
zone 5 = 1 coffee machine
sound power of speaker = 10-4
Air conditioner = 10-8
Fan = 10-7
Coffee Machine =10-5
Exhaust Fan = 10-6
82
6.4.2 Sound Pressure Level Calculation
Zone 1: Sitting Area
Figure 6.4.2.1 : Zone 1 Acoustic Equipment
4 speakers
1 ceiling fan
4 air conditioner
Total Intensities = (4 X 10-4
) + 10-7
+ (4 X 10-8
)
=4 X 10-4
SPL (dB) = 10log (I / Iref)
= 10log ((4 X 10-4
) / 10-12
)
=86.02 dB
83
Zone 2 : Outdoor Sitting Area
Figure 6.4.2.2 : Zone 2 Acoustic Equipment
Zone 2
2 fan
2 speakers
Total Intensities = (2 X 10-7
) + (2 X 10-4
)
=2 X 10-4
SPL (dB) = 10log (I / Iref)
= 10log ((2 X 10-4
) / 10-12
)
=83.01 dB
84
Zone 3 : Private Gathering Area
Figure 6.4.2.3 : Zone 3 Acoustic Equipment
Zone 3
1 speaker
1 aircon
Total Intensities = (1 X 10-8
) + (1 X 10-4
)
=1 X 10-4
SPL (dB) = 10log (I / Iref)
= 10log ((1 X 10-4
) / 10-12
) =80 dB
85
Zone 4 : Storage Room
Figure 6.4.2.4 : Zone 4 Acoustic Equipment
Zone 4
1 aircon
Total Intensities = 1 X 10-8
SPL (dB) = 10log (I / Iref)
= 10log ((1 X 10-8
) / 10-12
)
=40 dB
86
Zone 5 : Coffee Counter
Figure 6.4.2.5 : Zone 5 Acoustic Equipment
Zone 5
1 coffee machine
Total Intensities = 1 X 10-5
SPL (dB) = 10log (I / Iref)
= 10log ((1 X 10-5
) / 10-12
)
=70 dB
87
6.4.3 Spaces Acoustic Analysis
Zone 2 - Outdoor sitting area
Non-peak hour
Highest reading: 67 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 67/10
X 10-12
I= 106.7
X 10-12
I= 10-5.3
Lowest reading: 62 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 62/10
X 10-12
I= 106.2
X 10-12
I= 10-5.8
Total Intensities, I = (1 x 10-5.3
) + (1 x 10-5.8
)
= 6.6 x 10-6
SPL = 10log (I / Iref)
= 10log (6.6 x 10-6
/ 1 X 10-12
)
= 68.2 dB
Peak Hour
Highest reading: 86 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 86/10
X 10-12
I= 108.6
X 10-12
I= 10-3.4
Lowest reading: 77 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 77/10
X 10-12
I= 107.7
X 10-12
I= 10-4.3
88
Total Intensities, I = (1 x 10-3.4
) + (1 x 10-4.3
)
= 4.48 x 10-4
SPL = 10log (I / Iref)
= 10log (4.48 x 10-4
/ 1 X 10-12
)
= 86.51 dB
Zone 4 - Storage Room
Non-peak hour
Highest reading: 34 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 34/10
X 10-12
I= 103.4
X 10-12
I= 10-8,6
Lowest reading: 32 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 32/10
X 10-12
I= 103.2
X 10-12
I= 10-8.8
Total Intensities, I = (1 x 10-8.6
) + (1 x 10-8.8
)
= 4.09 x 10-9
SPL = 10log (I / Iref)
= 10log (4.09 x 10-9
/ 1 X 10-12
)
= 36.12 dB
Peak Hour
Highest reading: 66 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 66/10
X 10-12
I= 106.6
X 10-12
I= 10-5.4
Lowest reading: 57 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 57/10
X 10-12
I= 105.7
X 10-12
I= 10-6.3
89
Total Intensities, I = (1 x 10-5.4
) + (1 x 10-6.3
)
= 4.48 x 10-6
SPL = 10log (I / Iref)
= 10log (4.48 x 10-6
/ 1 X 10-12
)
= 66.51 dB
Zone 1 - Sitting Area
Non-peak hour
Highest reading: 74 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 74/10
X 10-12
I= 107.4
X 10-12
I= 10-5.6
Lowest reading: 42 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 42/10
X 10-12
I= 104.2
X 10-12
I= 10-7.8
Total Intensities, I = (1 x 10-5.6
) + (1 x 10-7.8
)
= 2.53 x 10-6
SPL = 10log (I / Iref)
= 10log (2.53 x 10-6
/ 1 X 10-12
)
= 64.03 dB
Peak Hour
Highest reading: 86 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 86/10
X 10-12
I= 108.6
X 10-12
I= 10-3.4
Lowest reading: 64 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 64/10
X 10-12
I= 106.4
X 10-12
I= 10-5.6
90
Total Intensities, I = (1 x 10-3.4
) + (1 x 10-5.6
)
= 4 x 10-4
SPL = 10log (I / Iref)
= 10log (4 x 10-4
/ 1 X 10-12
)
= 86.03 dB
Zone 5 - Coffee Counter
Non-peak hour
Highest reading: 75 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 75/10
X 10-12
I= 107.5
X 10-12
I= 10-5.5
Lowest reading: 63 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 63/10
X 10-12
I= 106.3
X 10-12
I= 10-5.4
Total Intensities, I = (1 x 10-5.5
) + (1 x 10-5.4
)
= 7.14 x 10-6
SPL = 10log (I / Iref)
= 10log (7.14 x 10-6
/ 1 X 10-12
)
= 68.54 dB
Peak Hour
Highest reading: 86 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 86/10
X 10-12
I= 108.6
X 10-12
I= 10-3.4
Lowest reading: 70 dB
SPL (dB) = 10log (I / Iref)
I = 10dB/10
X Iref
I= 10 70/10
X 10-12
I= 107
X 10-12
I= 10-5
91
Total Intensities, I = (1 x 10-3.4
) + (1 x 10-5
)
= 4.08 x 10-4
SPL = 10log (I / Iref)
= 10log (4.08 x 10-4
/ 1 X 10-12
)
= 86.11 dB
92
6.4.4 Reverberation Time Calculation
Reverberation time is calculated to determine the amount of sound energy that is absorbed
into the different types of construction materials in the structure as well as the interior
elements such as building occupants and furniture that are housed within this closed space.
The Reverberation time can be calculated by using Sabine's Equation:
RT60 = (0.16 X V) / A
where RT60 is the time taken for the noise to drop 60dB below original level (known as
Reverberation Time), V is volume of the enclosure, and A being the absorption coefficient
of the total area.
Calculated Space
Seating area (Zone 1) + Cafe bar (Zone 5) + Mezzanine Floor (Zone 1)
Reverberation times are calculated based on different material absorption coefficient at
500Hz, 2000Hz and 4000Hz for peak and non-peak hours.
- Material Absorption Coefficient at 500Hz for non-peak hours.
- Material Absorption Coefficient at 2000Hz for non-peak hours.
- Material Absorption Coefficient at 4000Hz for non-peak hours.
- Material Absorption Coefficient at 500Hz for peak hours.
- Material Absorption Coefficient at 2000Hz for peak hours.
- Material Absorption Coefficient at 4000Hz for peak hours.
Volume of calculated space
= 5.7m X [(11.85m X 5.73m) + (10m X 5.5m)]
= 700.53m3
93
Reverberation Time at 500Hz / Non-Peak Hour
Table 6.4.4.1 : Reverberation Time at 500Hz
RT60 = (0.16 X V) / A
= (0.16 X 700.53) / 45.3507
= 2.47s
Component Material Function Area(m2
)
[A]/ Quantity
Absorption
Coefficient
[S]
Sound
Absorption
[SA]
Ceiling Plaster
(Gypsum
Board,
Smooth finish
on lath)
Ceiling 122.29 0.06 7.3374
Steel
(Painted)
Mezzanine
Truss
14.84 0.44 6.5296
Wall Brick
(Unglazed)
Wall 38.3 0.03 1.149
Plaster (White,
Smooth finish
on brick)
Wall 16.32 0.02 0.3264
Plaster
(Black,
Smooth finish
on brick)
Wall 105.05 0.02 2.101
Glass (Large
pane)
Fixed-Panel 52.91 0.04 2.1164
Openings Glass (Large
Pane)
Pivot Door 3.52 0.04 0.1408
Timber
(Plywood)
Pivot Door 4.4 0.15 0.66
Steel
(Painted)
Folding Door 2.2 0.44 0.968
Floor Concrete
Screed
Floor 122.29 0.015 1.83435
FiberBoard Mezzanine
Floor
38.77 0.06 2.3262
Furniture Timber Table, Chair 5.87 0.15 0.8805
Timber Cupboard 5.8 0.05 0.29
Ceramic Countertop 6.54 0.01 0.0654
Concrete
screed
Counter 44.43 0.015 0.66645
Fabric Sofa 7.96 0.77 6.1292
MDF Sofa 13.3 0.1 1.33
People (Non-
Peak Hour)
25 0.42 10.5
Total Absorption [A] 45.3507
The reverberation time for the cafe at 500Hz
during non-peak hours is 2.47 seconds which is
adequately within the intended 1.5 – 2.5
seconds for public space that requires both
speech and music activities.
94
Reverberation Time at 2000Hz / Non-Peak Hour
Table 6.4.4.2 : Reverberation Time at 2000Hz
RT60 = (0.16 X V) / A
= (0.16 X 700.53) / 47.0248
= 2.38s
Component Material Function Area(m2
)
[A]/ Quantity
Absorption
Coefficient
[S]
Sound
Absorption
[SA]
Ceiling Plaster
(Gypsum
Board,
Smooth finish
on lath)
Ceiling 122.29 0.04 4.8916
Steel
(Painted)
Mezzanine
Truss
14.84 0.54 8.0136
Wall Brick
(Unglazed)
Wall 38.3 0.05 1.915
Plaster (White,
Smooth finish
on brick)
Wall 16.32 0.02 0.3264
Plaster
(Black,
Smooth finish
on brick)
Wall 105.05 0.02 2.101
Glass (Large
pane)
Fixed-Panel 52.91 0.02 1.0582
Openings Glass (Large
Pane)
Pivot Door 3.52 0.02 0.0704
Timber
(Plywood)
Pivot Door 4.4 0.1 0.44
Steel
(Painted)
Folding Door 2.2 0.54 1.188
Floor Concrete
Screed
Floor 122.29 0.02 2.4458
Fiber Board Mezzanine
Floor
38.77 0.08 3.1016
Furniture Timber Table, Chair 5.87 0.18 1.0566
Timber Cupboard 5.8 0.05 0.29
Ceramic Countertop 6.54 0.02 0.1308
Concrete
screed
Counter 44.43 0.02 0.8886
Fabric Sofa 7.96 0.82 6.5272
MDF Sofa 13.3 0.1 1.33
People (Non-
Peak Hour)
25 0.45 11.25
Total Absorption [A] 47.0248
The reverberation time for the cafe at 2000Hz
during non-peak hours is at 2.38 seconds. This
falls within the comfortable range of the public
space which is between 1.5 – 2.5 seconds.
95
Reverberation Time at 4000Hz / Non-Peak Hour
Table 6.4.4.3 : Reverberation Time at 4000Hz
RT60 = (0.16 X V) / A
= (0.16 X 700.53) / 46.1093
= 2.43s
Component Material Function Area(m2
)
[A]/ Quantity
Absorption
Coefficient
[S]
Sound
Absorption
[SA]
Ceiling Plaster
(Gypsum
Board,
Smooth finish
on lath)
Ceiling 122.29 0.03 3.6687
Steel
(Painted)
Mezzanine
Truss
14.84 0.57 8.4588
Wall Brick
(Unglazed)
Wall 38.3 0.07 2.681
Plaster (White,
Smooth finish
on brick)
Wall 16.32 0.02 0.3264
Plaster
(Black,
Smooth finish
on brick)
Wall 105.05 0.02 2.101
Glass (Large
pane)
Fixed-Panel 52.91 0.02 1.0582
Openings Glass (Large
Pane)
Pivot Door 3.52 0.02 0.0704
Timber
(Plywood)
Pivot Door 4.4 0.07 0.308
Steel
(Painted)
Folding Door 2.2 0.57 1.254
Floor Concrete
Screed
Floor 122.29 0.02 2.4458
Fiber Board Mezzanine
Floor
38.77 0.08 3.1016
Furniture Timber Table, Chair 5.87 0.2 1.174
Timber Cupboard 5.8 0.05 0.29
Ceramic Countertop 6.54 0.02 0.1308
Concrete
screed
Counter 44.43 0.02 0.8886
Fabric Sofa 7.96 0.7 5.572
MDF Sofa 13.3 0.1 1.33
People (Non-
Peak Hour)
25 0.45 11.25
Total Absorption [A] 46.1093
The reverberation time for the cafe at 4000Hz
during non-peak hours is 2.43 seconds. This is
considered acceptable for a space that requires
a balance of speech and music.
96
Reverberation Time at 500Hz / Peak Hour
Table 6.4.4.4 : Reverberation Time at 500Hz
RT60 = (0.16 X V) / A
= (0.16 X 700.53) / 66.3507
= 1.69s
Component Material Function Area(m2
)
[A]/ Quantity
Absorption
Coefficient
[S]
Sound
Absorption
[SA]
Ceiling Plaster
(Gypsum
Board,
Smooth finish
on lath)
Ceiling 122.29 0.06 7.3374
Steel
(Painted)
Mezzanine
Truss
14.84 0.44 6.5296
Wall Brick
(Unglazed)
Wall 38.3 0.03 1.149
Plaster (White,
Smooth finish
on brick)
Wall 16.32 0.02 0.3264
Plaster
(Black,
Smooth finish
on brick)
Wall 105.05 0.02 2.101
Glass (Large
pane)
Fixed-Panel 52.91 0.04 2.1164
Openings Glass (Large
Pane)
Pivot Door 3.52 0.04 0.1408
Timber
(Plywood)
Pivot Door 4.4 0.15 0.66
Steel
(Painted)
Folding Door 2.2 0.44 0.968
Floor Concrete
Screed
Floor 122.29 0.015 1.83435
FiberBoard Mezzanine
Floor
38.77 0.06 2.3262
Furniture Timber Table, Chair 5.87 0.15 0.8805
Timber Cupboard 5.8 0.05 0.29
Ceramic Countertop 6.54 0.01 0.0654
Concrete
screed
Counter 44.43 0.015 0.66645
Fabric Sofa 7.96 0.77 6.1292
MDF Sofa 13.3 0.1 1.33
People (Peak
Hour)
75 0.42 31.5
Total Absorption [A] 66.3507
The reverberation time for the cafe at 500Hz
during peak hours is 1.69 seconds. This is well
within the boundary of 1.5 – 2.5 seconds and
shows that the cafe has adequate acoustic
absorption properties.
97
Reverberation Time at 2000Hz / Peak Hour
Table 6.4.4.5 : Reverberation Time at 2000Hz
RT60 = (0.16 X V) / A
= (0.16 X 700.53) / 69.5248
= 1.61s
Component Material Function Area(m2
)
[A]/ Quantity
Absorption
Coefficient
[S]
Sound
Absorption
[SA]
Ceiling Plaster
(Gypsum
Board,
Smooth finish
on lath)
Ceiling 122.29 0.04 4.8916
Steel
(Painted)
Mezzanine
Truss
14.84 0.54 8.0136
Wall Brick
(Unglazed)
Wall 38.3 0.05 1.915
Plaster (White,
Smooth finish
on brick)
Wall 16.32 0.02 0.3264
Plaster
(Black,
Smooth finish
on brick)
Wall 105.05 0.02 2.101
Glass (Large
pane)
Fixed-Panel 52.91 0.02 1.0582
Openings Glass (Large
Pane)
Pivot Door 3.52 0.02 0.0704
Timber
(Plywood)
Pivot Door 4.4 0.1 0.44
Steel
(Painted)
Folding Door 2.2 0.54 1.188
Floor Concrete
Screed
Floor 122.29 0.02 2.4458
Fiber Board Mezzanine
Floor
38.77 0.08 3.1016
Furniture Timber Table, Chair 5.87 0.18 1.0566
Timber Cupboard 5.8 0.05 0.29
Ceramic Countertop 6.54 0.02 0.1308
Concrete
screed
Counter 44.43 0.02 0.8886
Fabric Sofa 7.96 0.82 6.5272
MDF Sofa 13.3 0.1 1.33
People (Peak
Hour)
75 0.45 33.75
Total Absorption [A] 69.5248
At 2000Hz. the reverberation time for the cafe
during peak hours is 1.61 seconds which
satisfies the requirement of such space to be
within 1.5 – 2.5 seconds.
98
Reverberation Time at 4000Hz / Peak Hour
Table 6.4.4.6 : Reverberation Time at 4000Hz
RT60 = (0.16 X V) / A
= (0.16 X 700.53) / 68.6093
= 1.63s
Component Material Function Area(m2
)
[A]/ Quantity
Absorption
Coefficient
[S]
Sound
Absorption
[SA]
Ceiling Plaster
(Gypsum
Board,
Smooth finish
on lath)
Ceiling 122.29 0.03 3.6687
Steel
(Painted)
Mezzanine
Truss
14.84 0.57 8.4588
Wall Brick
(Unglazed)
Wall 38.3 0.07 2.681
Plaster (White,
Smooth finish
on brick)
Wall 16.32 0.02 0.3264
Plaster
(Black,
Smooth finish
on brick)
Wall 105.05 0.02 2.101
Glass (Large
pane)
Fixed-Panel 52.91 0.02 1.0582
Openings Glass (Large
Pane)
Pivot Door 3.52 0.02 0.0704
Timber
(Plywood)
Pivot Door 4.4 0.07 0.308
Steel
(Painted)
Folding Door 2.2 0.57 1.254
Floor Concrete
Screed
Floor 122.29 0.02 2.4458
Fiber Board Mezzanine
Floor
38.77 0.08 3.1016
Furniture Timber Table, Chair 5.87 0.2 1.174
Timber Cupboard 5.8 0.05 0.29
Ceramic Countertop 6.54 0.02 0.1308
Concrete
screed
Counter 44.43 0.02 0.8886
Fabric Sofa 7.96 0.7 5.572
MDF Sofa 13.3 0.1 1.33
People (Peak
Hour)
75 0.45 33.75
Total Absorption [A] 68.6093
The reverberation time for the cafe at 4000Hz
during peak hours is 1.63 seconds. This falls
within the required range 1.5 – 2.5 seconds. This
range is the general range for spaces that
requires a balance mix of speech and music.
99
Reverberation Time Analysis and Conclusion
From the gathered data, the reverberation timing for 500Hz, 2000Hz and 4000Hz could be
acquired and there is a noticeable pattern that emerged from both peak and non-peak hours.
The reverberation time for non-peak hours are gathered at the higher end of the desired
range of 1.5 to 2.5 seconds while the reverberation time for peak hours are reduced to the
lower end of the range. The reverberation time is indirectly proportional to the amount of
occupants inside the space as people contributes significantly towards acoustic absorption
of the space and help enhance it.
The reasons why the cafe has a high reverberation time is due to the double volume of the
space which has a height of 5.7 meters. This high reverberation time is further bolstered by
the lack of acoustic absorbing materials such as concrete, which, when sound reaches the
material, get reflected more than it gets absorbed, and consequently creating a higher
reverberation time.
Even though the reverberation time is quite high for a comfort human range of 0.8 to 1.3
seconds, it is quite acceptable for a cafe that requires the balance blend between soft music
and relaxing conversation. Hence, it is safe to say that the cafe has a good acoustic
reverberation properties.
100
6.4.5 Sound Reduction Index Calculation
Sound Reduction Index
The first floor sitting area is identified as the main space to analyze the acoustic
transmission from and into the area. Not only that this space incorporates the main sitting
area (ZONE 1) and the coffee counter (ZONE 2), but as well as the immediate outdoor
sitting area. The outdoor sitting area (ZONE 3) is established as the secondary area to
record sound transmission into that particular space, in order to understand whether acoustic
measures such as the selection of materials are sufficient to buffer sound between these
spaces and is essential to identify the acoustic ratings of these two spaces.
For main sitting area and coffee counter area:
Figure 6.4.5.1 : Zone 1 Plan
101
Main Area + Cafe Bar
Materials Surface Area (m2
) Transmission
coefficient of
material
Sn X Tcn
Concrete Wall 131.53 6.31 X 10-5
8.3 X 10-3
Brick Wall 40.54 5.01 X 10-6
2.03 X 10-4
Glass Wall 61.51 2.51 X 10-4
1.54 X 10-2
Glass Door 3.52 2.51 X 10-4
8.84 X 10-4
Total Surface
Area
246.1
Table 6.4.5.1 : SRI Tabulation
TAV = (8.3 X 10-3
+ 2.03 X 10-4
+ 1.54 X 10-2
+ 8.84 X 10-4
) / Total Surface
Area
= 2.48 X 10-2
SRI Overall = 10Log10 (1 / 2.48 X 10-2
)
SRI Overall = 16.06 dB
102
For outdoor sitting area:
Figure 6.4.5.2 : Zone 2 Plan
Private Gathering Space
Materials Surface Area (m2
) Transmission
coefficient of
material
Sn X Tcn
Concrete Wall 30.78 6.31 X 10-5
1.94 X 10-3
Brick Wall 14.7 5.01 X 10-6
7.36 X 10-5
Glass Wall 36.82 2.51 X 10-4
9.24 X 10-3
Glass Door 2.2 2.51 X 10-4
5.52 X 10-4
Total Surface
Area
84.5
Table 6.4.5.2 : SRI Tabulation
TAV = (1.94 X 10-3
+ 7.36 X 10-5
+ 9.24 X 10-3
+ 5.52 X 10-4
) / Total Surface
Area
= 1.4 X 10-4
SRI Overall = 10Log10 (1 / 1.4 X 10-4
)
SRI Overall = 38.53 dB
103
6.5 Analysis and Evaluation
Table: Sound Environments with their corresponding Sound Pressure Levels(Source:
http://trace.wisc.edu/docs/2004-About-dB/)
With reference to the table of general sound environments, the noise level readings of the
main and private sitting areas are averagely between 60-79dB, which means that the noise
levels in these areas are from normal to four times as loud as a conversation noise level. It is
considered as a typical acoustic trait, being a café with customers converse, as well as
music being played from the speakers.
The coffee counter has a relatively higher reading of 70-89dB, which is four times
louder than the sound level of a normal conversation. The high readings were contributed by
the noise level from the coffee machines and grinders that are being utilized from time to
time. The noise level of the coffee counter is also contributed by the use of speakers for
background music in the café.
Artisan Café has a typical overall noise levels that are common in other cafes and
restaurants. However, during peak hours it may be quite loud, as the more customers there
are in the café, the higher volume of music being played on the speakers will be used to
mask the conversation noises.
104
7.0 REFERENCES
1. STC Chart (n.d.).STC Ratings for Brick and Concrete Block. Retrieved from
http://www.sae.edu/reference material/pages/STC%20Chart.html
2. Paroc Group (2014). Sound Insulation. Retrieved from
http://www.paroc.com/knowhow/sound/sound-insulation
3. ThomasNet (2014).Sound Absorption Coefficients. Retrieved from
http://www.sae.edu/reference material/pages/Coeffieicnet%20Chart.html
4. Hongkong Institute of Architects.(2008). Wave Motion, Noise Control in Architecture.
5. Harris, Cyril M. Noise Control in Buildings: A Practical Guide for Architects and Engineers.
NewYork: McGraw-Hill, 1993.
6. Neufert, Ernst and Peter.Neufert Architects’ Data. Oxford: Wilet-Blackwell, 2012
7. AZO Network (2014). Sound Transmission and Insulation in Brick and Masonry
Walls.Retrieve from
http://www.azom.com/article.aspx?ArticleID=1326
8. Deru, M., Torcellini, P., Sheffer, M., & Lau, A. (2005).Analysis of the Design and Energy
Performance of the Pennsylvania Department of Environmental protection Cambria Office
Building. Doi:10.2172/15016075
9. INTERIOR LIGHTING DESIGN A STUDENT’S GUIDE. (n.d.) Retrieved from
http://www.slideshare.net/nosuhaila/interior-lighting-design-a-students-guide
105
10. Malaysia. (2007). Code of practice on energy efficiency and use of renewable energy for non-
residential buildings (first revision).Putrajaya: Department of Standard Malaysia.
11. Subtle variations: the uses of artificial and natural light in the menil collection, Houston,
texas, (n.d) Retrieved from
http://www.arch.ced.berkeley.edu/vitalsigns/bld/toolkit_studies/menil%20collection%20--
%20Subtle%20Variations.pdf
12. Technical – Photometric Data Guid. (n.d) Retrieved from
http://lightsbylinea.com/index.php?route=information%2Finformation&information_id=10
13. Robert B. (n.d) Noise Control for Buildings. Guidelines for Acoustical Problem Solving
Retrieve from
http://www.certainteed.com/resources/NoiseControl%20Brochure%203
14. Long, M. (2006). Architectural acoustics. Amsterdam: Elsevier/Academic Press.
15. Barton, C.K,.& Construction Engineering Research Laboratory. (1987). Development of LITE
graphic module for lighting analysis in the Computer-Aided Engineering and Architectural
Design System(CAEADS). Champaign, IL: US Army Corps of Engineers, Construction
Engineering Research Laboratory.
16. Calculux Indoor – Philips Lighting Singapore. (n.d) Retrieved from
http://www.lighting.philips.com/pwc_li/cn_zh/connect/tools_literature/Assets/downloads/
manual_indoor.pdfCIBSE. (2002). Code for lighting. Burlington: Elsevier.
17 Coefficient Chart. (n.d). Retrieved from
http://www.sae.edu/reference_material/pages/Coefficient%20Chart.htm
106
8.0 APPENDIX
LIST OF FIGURES
Figure 2.1.1 : Image of Solar Decathlon House
Figure 2.1.1: Floor Plan of Solar Decathlon House
Diagram 2.1.2 : Analysis Diagram
Figure 2.2.1 : Yildiz Technical University Auditorium
Figure 2.2.2: Section of the YTU auditorium (after renovation)
Figure 2.2.3: Plan of YTU auditorium (after renovation)
Figure 3.1.1 : digital lux meter
Diagram3.1.1 : Standard height used to record Lux readings
Figure 3.2.1 : Digital Sound Level Meter
Figure4.1.2: Site Context of the Cafe
Figure 4.7.1 : Ground Floor Zoning
Figure 4.7.2 : Mezzanine Floor Zoning
Diagram 5.2.1 Daylight Lux Contour Diagram
Diagram 5.2.2 Artificial Lux Contour Diagram
Figure 6.1.2: Placement of Air Circulators
Figure 6.1.3: Human activity point
Figure 6.1.4: Position of Speakers
107
LIST OF TABLES
Table 2.1.1 : Materiality Reflectance Table
Table 2.2.1:Surface materials in auditorium, their surface area and absorption coefficient
(based on Harris, 1994:Cavanaugh & Wilco, 1999)
Table 2.2.2 RTs Calculation
Table 2.2.3 : Measured and acceptable BSLs (air conditioning)
Table 2.2.4: Measured, calculated and optimum RTs of YTU auditorium for speech activities
Table 4.1.1 Artifial Lighting Sources
Table 4.1.2 Acoustic Sources
Table 5.1.1 Daytime Lux Readings
Table 5.1.2 Nightime Lux Readings
Table 6.2.1 Peak and Non - Peak Hours Readings
108

More Related Content

What's hot

Project 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and DesignProject 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and DesignAngeline KH
 
Bscience 2-project-2
Bscience 2-project-2Bscience 2-project-2
Bscience 2-project-2
Megan Chung
 
Final report
Final reportFinal report
Final report
Chuah Say Yin
 
B.science report 1.2
B.science report 1.2B.science report 1.2
B.science report 1.2
Elaine Bong
 
Bscience report
Bscience reportBscience report
Bscience report
kerneng
 
Lighting Analysis Project 1
Lighting Analysis Project 1Lighting Analysis Project 1
Lighting Analysis Project 1
J-Sern Phua
 
Bscience
BscienceBscience
Bscience
kimberlywjs
 
Lighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute CoffeeLighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute Coffee
Octonio Octonio
 
Light Analysis of Building Science II
Light Analysis of Building Science IILight Analysis of Building Science II
Light Analysis of Building Science II
jernjack
 
Building science ii project 1 compiled
Building science ii project 1 compiledBuilding science ii project 1 compiled
Building science ii project 1 compiled
Devinchi
 
Building Science II: Lighting Integration Report
Building Science II: Lighting Integration ReportBuilding Science II: Lighting Integration Report
Building Science II: Lighting Integration Report
Ee Dong Chen
 
BSCIENCE LIGHTING REPORT
BSCIENCE LIGHTING REPORTBSCIENCE LIGHTING REPORT
BSCIENCE LIGHTING REPORT
Pei Di
 
Building science report ...
Building science report                                                      ...Building science report                                                      ...
Building science report ...
Tsang Hao Ren
 
Building Science Project 1 Brief
Building Science Project 1 BriefBuilding Science Project 1 Brief
Building Science Project 1 Brief
JoyeeLee0131
 
Lighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and DesignLighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and Design
nadiacbass
 
Acoustic Analysis Project 1
Acoustic Analysis Project 1Acoustic Analysis Project 1
Acoustic Analysis Project 1
J-Sern Phua
 
Building science 2
Building science 2Building science 2
Building science 2
Eunice Chan
 
Building Science II
Building Science IIBuilding Science II
Building Science II
jernjack
 

What's hot (19)

Project 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and DesignProject 1-Lighting & Acoustic Performance Evaluation and Design
Project 1-Lighting & Acoustic Performance Evaluation and Design
 
Bscience 2-project-2
Bscience 2-project-2Bscience 2-project-2
Bscience 2-project-2
 
Final report
Final reportFinal report
Final report
 
B.science report 1.2
B.science report 1.2B.science report 1.2
B.science report 1.2
 
Bscience report
Bscience reportBscience report
Bscience report
 
Lighting Analysis Project 1
Lighting Analysis Project 1Lighting Analysis Project 1
Lighting Analysis Project 1
 
Bscience
BscienceBscience
Bscience
 
Lighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute CoffeeLighting and Acoustic Performance - Absolute Coffee
Lighting and Acoustic Performance - Absolute Coffee
 
Light Analysis of Building Science II
Light Analysis of Building Science IILight Analysis of Building Science II
Light Analysis of Building Science II
 
Building science ii project 1 compiled
Building science ii project 1 compiledBuilding science ii project 1 compiled
Building science ii project 1 compiled
 
Building Science II: Lighting Integration Report
Building Science II: Lighting Integration ReportBuilding Science II: Lighting Integration Report
Building Science II: Lighting Integration Report
 
BSCIENCE LIGHTING REPORT
BSCIENCE LIGHTING REPORTBSCIENCE LIGHTING REPORT
BSCIENCE LIGHTING REPORT
 
Building science report ...
Building science report                                                      ...Building science report                                                      ...
Building science report ...
 
Building Science Project 1 Brief
Building Science Project 1 BriefBuilding Science Project 1 Brief
Building Science Project 1 Brief
 
Final l
Final lFinal l
Final l
 
Lighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and DesignLighting & Acoustic Performance Evaluation and Design
Lighting & Acoustic Performance Evaluation and Design
 
Acoustic Analysis Project 1
Acoustic Analysis Project 1Acoustic Analysis Project 1
Acoustic Analysis Project 1
 
Building science 2
Building science 2Building science 2
Building science 2
 
Building Science II
Building Science IIBuilding Science II
Building Science II
 

Viewers also liked

Cn forklif training centre seo
Cn forklif training centre seoCn forklif training centre seo
Cn forklif training centre seo
CN forklift Training Centre
 
Driver Behavioral Analysis in Heterogeneous Traffic Conditions
Driver Behavioral Analysis in Heterogeneous Traffic ConditionsDriver Behavioral Analysis in Heterogeneous Traffic Conditions
Driver Behavioral Analysis in Heterogeneous Traffic Conditions
Vibhanshu Singh
 
New Ford Mondeo Suspension Vehicle Dynamics International
New Ford Mondeo Suspension Vehicle Dynamics InternationalNew Ford Mondeo Suspension Vehicle Dynamics International
New Ford Mondeo Suspension Vehicle Dynamics InternationalPaul Zandbergen
 
20170206 セミナー資料 講演利用資料_009
20170206 セミナー資料 講演利用資料_00920170206 セミナー資料 講演利用資料_009
20170206 セミナー資料 講演利用資料_009
J-Phoenix Research Inc.
 
Mustang 50 Years Chassis Tech
Mustang 50 Years Chassis TechMustang 50 Years Chassis Tech
Mustang 50 Years Chassis TechPaul Zandbergen
 
Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016
Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016
Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016
Phillip A. Weston
 
Projected vehicle reduction_Fall 2016
Projected vehicle reduction_Fall 2016Projected vehicle reduction_Fall 2016
Projected vehicle reduction_Fall 2016Christopher Garlitz
 
Smau Napoli 2016 Corporate Meeting - MegaRide
Smau Napoli 2016 Corporate Meeting - MegaRideSmau Napoli 2016 Corporate Meeting - MegaRide
Smau Napoli 2016 Corporate Meeting - MegaRide
SMAU
 
DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...
DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...
DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...
IAEME Publication
 
getting-started-with-lotus-suspension-analysis
getting-started-with-lotus-suspension-analysisgetting-started-with-lotus-suspension-analysis
getting-started-with-lotus-suspension-analysis
Upender Rawat
 
Tilting of vehicle
Tilting of vehicleTilting of vehicle
Tilting of vehicle
Siddharth Maniyar
 
Chapter 2
Chapter 2Chapter 2
Chapter 2
EWIT
 
Analysis and simulation of lap time: innovative tools for design and structur...
Analysis and simulation of lap time: innovative tools for design and structur...Analysis and simulation of lap time: innovative tools for design and structur...
Analysis and simulation of lap time: innovative tools for design and structur...
Marco E. Biancolini
 
Baja sae india suspension design
Baja sae india suspension designBaja sae india suspension design
Baja sae india suspension design
Upender Rawat
 
presentation on the literature and case study of cricket stadium
presentation on the literature and case study of cricket stadium presentation on the literature and case study of cricket stadium
presentation on the literature and case study of cricket stadium
Kathmandu Engineering College
 
Dynamic weight transfer in vehicle
Dynamic weight transfer in vehicleDynamic weight transfer in vehicle
Dynamic weight transfer in vehicle
Rohan Sahdev
 
100 نشاط تدريبي
100 نشاط تدريبي100 نشاط تدريبي
100 نشاط تدريبي
coachingclublibrary
 
денисенко катерина вікторівна
денисенко катерина вікторівнаденисенко катерина вікторівна
денисенко катерина вікторівнаIlona Bacurovska
 
Impact on investments in turkey 2002 2010
Impact on investments in turkey 2002 2010Impact on investments in turkey 2002 2010
Impact on investments in turkey 2002 2010
Mumtoz Muzaffarov
 

Viewers also liked (20)

Cn forklif training centre seo
Cn forklif training centre seoCn forklif training centre seo
Cn forklif training centre seo
 
Driver Behavioral Analysis in Heterogeneous Traffic Conditions
Driver Behavioral Analysis in Heterogeneous Traffic ConditionsDriver Behavioral Analysis in Heterogeneous Traffic Conditions
Driver Behavioral Analysis in Heterogeneous Traffic Conditions
 
New Ford Mondeo Suspension Vehicle Dynamics International
New Ford Mondeo Suspension Vehicle Dynamics InternationalNew Ford Mondeo Suspension Vehicle Dynamics International
New Ford Mondeo Suspension Vehicle Dynamics International
 
Portfolio_Oier_Bañuelos
Portfolio_Oier_BañuelosPortfolio_Oier_Bañuelos
Portfolio_Oier_Bañuelos
 
20170206 セミナー資料 講演利用資料_009
20170206 セミナー資料 講演利用資料_00920170206 セミナー資料 講演利用資料_009
20170206 セミナー資料 講演利用資料_009
 
Mustang 50 Years Chassis Tech
Mustang 50 Years Chassis TechMustang 50 Years Chassis Tech
Mustang 50 Years Chassis Tech
 
Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016
Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016
Meppen, Ritchie Bros Timed Auction 20th to 30th of September 2016
 
Projected vehicle reduction_Fall 2016
Projected vehicle reduction_Fall 2016Projected vehicle reduction_Fall 2016
Projected vehicle reduction_Fall 2016
 
Smau Napoli 2016 Corporate Meeting - MegaRide
Smau Napoli 2016 Corporate Meeting - MegaRideSmau Napoli 2016 Corporate Meeting - MegaRide
Smau Napoli 2016 Corporate Meeting - MegaRide
 
DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...
DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...
DETERMINATION OF HEAT TRANSFER COEFFICIENT OF BRAKE ROTOR DISC USING CFD SIMU...
 
getting-started-with-lotus-suspension-analysis
getting-started-with-lotus-suspension-analysisgetting-started-with-lotus-suspension-analysis
getting-started-with-lotus-suspension-analysis
 
Tilting of vehicle
Tilting of vehicleTilting of vehicle
Tilting of vehicle
 
Chapter 2
Chapter 2Chapter 2
Chapter 2
 
Analysis and simulation of lap time: innovative tools for design and structur...
Analysis and simulation of lap time: innovative tools for design and structur...Analysis and simulation of lap time: innovative tools for design and structur...
Analysis and simulation of lap time: innovative tools for design and structur...
 
Baja sae india suspension design
Baja sae india suspension designBaja sae india suspension design
Baja sae india suspension design
 
presentation on the literature and case study of cricket stadium
presentation on the literature and case study of cricket stadium presentation on the literature and case study of cricket stadium
presentation on the literature and case study of cricket stadium
 
Dynamic weight transfer in vehicle
Dynamic weight transfer in vehicleDynamic weight transfer in vehicle
Dynamic weight transfer in vehicle
 
100 نشاط تدريبي
100 نشاط تدريبي100 نشاط تدريبي
100 نشاط تدريبي
 
денисенко катерина вікторівна
денисенко катерина вікторівнаденисенко катерина вікторівна
денисенко катерина вікторівна
 
Impact on investments in turkey 2002 2010
Impact on investments in turkey 2002 2010Impact on investments in turkey 2002 2010
Impact on investments in turkey 2002 2010
 

Similar to Building science 2 project 1

Light report compiled
Light report compiledLight report compiled
Light report compiled
Preston Liew
 
Building Science II
Building Science IIBuilding Science II
Building Science II
Ivy Yee
 
Building Science 2
Building Science 2Building Science 2
Building Science 2
Gertrude Lee
 
Finaleeee bscience 2
Finaleeee bscience 2Finaleeee bscience 2
Finaleeee bscience 2
Ibrahim Adhnan
 
Project 1 performance evaluation
Project 1 performance evaluationProject 1 performance evaluation
Project 1 performance evaluation
Preston Liew
 
LIGHTING
LIGHTINGLIGHTING
LIGHTING
Pengeneee Peng
 
Light and architecture
Light and architectureLight and architecture
Light and architecture
Atul Pathak
 
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & DesignBuilding Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Adibah Awang
 
Project 2 integration
Project 2  integrationProject 2  integration
Project 2 integration
Preston Liew
 
Building science 2 P1 report pdf
Building science 2 P1 report pdfBuilding science 2 P1 report pdf
Building science 2 P1 report pdf
jayeshellayah
 
Daylight metrics and their sensitivity
Daylight metrics and their sensitivityDaylight metrics and their sensitivity
Daylight metrics and their sensitivity
Kathrine Brejnrod
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilation
Nicholas Yap Wei Tyng
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilation
kerneng
 
Sound final
Sound finalSound final
Sound final
Preston Liew
 
Project 2 integration (1)
Project 2  integration (1)Project 2  integration (1)
Project 2 integration (1)
Anthony Chew
 
Green Studio Handbook - Part 3
Green Studio Handbook - Part 3Green Studio Handbook - Part 3
Green Studio Handbook - Part 3Galala University
 
Building science ii final report
Building science ii final reportBuilding science ii final report
Building science ii final report
michelle siaw
 
Lit Interior.pdf
Lit Interior.pdfLit Interior.pdf
Lit Interior.pdf
vapheng
 
litinterior-220801075609-96ef1e66.pdf
litinterior-220801075609-96ef1e66.pdflitinterior-220801075609-96ef1e66.pdf
litinterior-220801075609-96ef1e66.pdf
vapheng
 
Report Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & AcousticsReport Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & Acoustics
Crysmond Goh
 

Similar to Building science 2 project 1 (20)

Light report compiled
Light report compiledLight report compiled
Light report compiled
 
Building Science II
Building Science IIBuilding Science II
Building Science II
 
Building Science 2
Building Science 2Building Science 2
Building Science 2
 
Finaleeee bscience 2
Finaleeee bscience 2Finaleeee bscience 2
Finaleeee bscience 2
 
Project 1 performance evaluation
Project 1 performance evaluationProject 1 performance evaluation
Project 1 performance evaluation
 
LIGHTING
LIGHTINGLIGHTING
LIGHTING
 
Light and architecture
Light and architectureLight and architecture
Light and architecture
 
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & DesignBuilding Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
Building Science Project 1 : Lighting & Acoustic Performance Evaluation & Design
 
Project 2 integration
Project 2  integrationProject 2  integration
Project 2 integration
 
Building science 2 P1 report pdf
Building science 2 P1 report pdfBuilding science 2 P1 report pdf
Building science 2 P1 report pdf
 
Daylight metrics and their sensitivity
Daylight metrics and their sensitivityDaylight metrics and their sensitivity
Daylight metrics and their sensitivity
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilation
 
Final bscience report compilation
Final bscience report compilationFinal bscience report compilation
Final bscience report compilation
 
Sound final
Sound finalSound final
Sound final
 
Project 2 integration (1)
Project 2  integration (1)Project 2  integration (1)
Project 2 integration (1)
 
Green Studio Handbook - Part 3
Green Studio Handbook - Part 3Green Studio Handbook - Part 3
Green Studio Handbook - Part 3
 
Building science ii final report
Building science ii final reportBuilding science ii final report
Building science ii final report
 
Lit Interior.pdf
Lit Interior.pdfLit Interior.pdf
Lit Interior.pdf
 
litinterior-220801075609-96ef1e66.pdf
litinterior-220801075609-96ef1e66.pdflitinterior-220801075609-96ef1e66.pdf
litinterior-220801075609-96ef1e66.pdf
 
Report Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & AcousticsReport Bscience 2 Evaluation Performance Lighting & Acoustics
Report Bscience 2 Evaluation Performance Lighting & Acoustics
 

More from Jannah Jailani

Part 2
Part 2Part 2
Part 1
Part 1Part 1
Project management project 1 report (pr architects)
Project management project 1 report (pr architects)Project management project 1 report (pr architects)
Project management project 1 report (pr architects)
Jannah Jailani
 
Portfolio final
Portfolio finalPortfolio final
Portfolio final
Jannah Jailani
 
Design report
Design reportDesign report
Design report
Jannah Jailani
 
Synopsis 4
Synopsis 4Synopsis 4
Synopsis 4
Jannah Jailani
 
Synopsis 3
Synopsis 3Synopsis 3
Synopsis 3
Jannah Jailani
 
Synopsis 2
Synopsis 2Synopsis 2
Synopsis 2
Jannah Jailani
 
Synopsis 1
Synopsis 1Synopsis 1
Synopsis 1
Jannah Jailani
 
Theories Project 1 final
Theories Project 1 finalTheories Project 1 final
Theories Project 1 final
Jannah Jailani
 
Theories Project 1 Part 1
Theories Project 1 Part 1Theories Project 1 Part 1
Theories Project 1 Part 1
Jannah Jailani
 
Theories Project 1 Part 2
Theories Project 1 Part 2Theories Project 1 Part 2
Theories Project 1 Part 2
Jannah Jailani
 
Islamic architecture project 2
Islamic architecture   project 2Islamic architecture   project 2
Islamic architecture project 2
Jannah Jailani
 
Turnitin results
Turnitin resultsTurnitin results
Turnitin results
Jannah Jailani
 
Asian architecture [arc2234] case study paper
Asian architecture [arc2234]   case study paperAsian architecture [arc2234]   case study paper
Asian architecture [arc2234] case study paper
Jannah Jailani
 
Building structures report [individual]
Building structures report [individual]Building structures report [individual]
Building structures report [individual]
Jannah Jailani
 
Building structure [arc 2523]
Building structure [arc 2523]Building structure [arc 2523]
Building structure [arc 2523]
Jannah Jailani
 
Building services report [final]
Building services report [final]Building services report [final]
Building services report [final]
Jannah Jailani
 
Church of Seed booklet
Church of Seed bookletChurch of Seed booklet
Church of Seed booklet
Jannah Jailani
 
Building science report [singapore] final
Building science report [singapore] finalBuilding science report [singapore] final
Building science report [singapore] finalJannah Jailani
 

More from Jannah Jailani (20)

Part 2
Part 2Part 2
Part 2
 
Part 1
Part 1Part 1
Part 1
 
Project management project 1 report (pr architects)
Project management project 1 report (pr architects)Project management project 1 report (pr architects)
Project management project 1 report (pr architects)
 
Portfolio final
Portfolio finalPortfolio final
Portfolio final
 
Design report
Design reportDesign report
Design report
 
Synopsis 4
Synopsis 4Synopsis 4
Synopsis 4
 
Synopsis 3
Synopsis 3Synopsis 3
Synopsis 3
 
Synopsis 2
Synopsis 2Synopsis 2
Synopsis 2
 
Synopsis 1
Synopsis 1Synopsis 1
Synopsis 1
 
Theories Project 1 final
Theories Project 1 finalTheories Project 1 final
Theories Project 1 final
 
Theories Project 1 Part 1
Theories Project 1 Part 1Theories Project 1 Part 1
Theories Project 1 Part 1
 
Theories Project 1 Part 2
Theories Project 1 Part 2Theories Project 1 Part 2
Theories Project 1 Part 2
 
Islamic architecture project 2
Islamic architecture   project 2Islamic architecture   project 2
Islamic architecture project 2
 
Turnitin results
Turnitin resultsTurnitin results
Turnitin results
 
Asian architecture [arc2234] case study paper
Asian architecture [arc2234]   case study paperAsian architecture [arc2234]   case study paper
Asian architecture [arc2234] case study paper
 
Building structures report [individual]
Building structures report [individual]Building structures report [individual]
Building structures report [individual]
 
Building structure [arc 2523]
Building structure [arc 2523]Building structure [arc 2523]
Building structure [arc 2523]
 
Building services report [final]
Building services report [final]Building services report [final]
Building services report [final]
 
Church of Seed booklet
Church of Seed bookletChurch of Seed booklet
Church of Seed booklet
 
Building science report [singapore] final
Building science report [singapore] finalBuilding science report [singapore] final
Building science report [singapore] final
 

Recently uploaded

Palestine last event orientationfvgnh .pptx
Palestine last event orientationfvgnh .pptxPalestine last event orientationfvgnh .pptx
Palestine last event orientationfvgnh .pptx
RaedMohamed3
 
A Strategic Approach: GenAI in Education
A Strategic Approach: GenAI in EducationA Strategic Approach: GenAI in Education
A Strategic Approach: GenAI in Education
Peter Windle
 
The Challenger.pdf DNHS Official Publication
The Challenger.pdf DNHS Official PublicationThe Challenger.pdf DNHS Official Publication
The Challenger.pdf DNHS Official Publication
Delapenabediema
 
Honest Reviews of Tim Han LMA Course Program.pptx
Honest Reviews of Tim Han LMA Course Program.pptxHonest Reviews of Tim Han LMA Course Program.pptx
Honest Reviews of Tim Han LMA Course Program.pptx
timhan337
 
The French Revolution Class 9 Study Material pdf free download
The French Revolution Class 9 Study Material pdf free downloadThe French Revolution Class 9 Study Material pdf free download
The French Revolution Class 9 Study Material pdf free download
Vivekanand Anglo Vedic Academy
 
Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46
Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46
Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46
MysoreMuleSoftMeetup
 
Home assignment II on Spectroscopy 2024 Answers.pdf
Home assignment II on Spectroscopy 2024 Answers.pdfHome assignment II on Spectroscopy 2024 Answers.pdf
Home assignment II on Spectroscopy 2024 Answers.pdf
Tamralipta Mahavidyalaya
 
Phrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXX
Phrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXXPhrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXX
Phrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXX
MIRIAMSALINAS13
 
Polish students' mobility in the Czech Republic
Polish students' mobility in the Czech RepublicPolish students' mobility in the Czech Republic
Polish students' mobility in the Czech Republic
Anna Sz.
 
Introduction to AI for Nonprofits with Tapp Network
Introduction to AI for Nonprofits with Tapp NetworkIntroduction to AI for Nonprofits with Tapp Network
Introduction to AI for Nonprofits with Tapp Network
TechSoup
 
Welcome to TechSoup New Member Orientation and Q&A (May 2024).pdf
Welcome to TechSoup   New Member Orientation and Q&A (May 2024).pdfWelcome to TechSoup   New Member Orientation and Q&A (May 2024).pdf
Welcome to TechSoup New Member Orientation and Q&A (May 2024).pdf
TechSoup
 
Overview on Edible Vaccine: Pros & Cons with Mechanism
Overview on Edible Vaccine: Pros & Cons with MechanismOverview on Edible Vaccine: Pros & Cons with Mechanism
Overview on Edible Vaccine: Pros & Cons with Mechanism
DeeptiGupta154
 
The geography of Taylor Swift - some ideas
The geography of Taylor Swift - some ideasThe geography of Taylor Swift - some ideas
The geography of Taylor Swift - some ideas
GeoBlogs
 
Francesca Gottschalk - How can education support child empowerment.pptx
Francesca Gottschalk - How can education support child empowerment.pptxFrancesca Gottschalk - How can education support child empowerment.pptx
Francesca Gottschalk - How can education support child empowerment.pptx
EduSkills OECD
 
678020731-Sumas-y-Restas-Para-Colorear.pdf
678020731-Sumas-y-Restas-Para-Colorear.pdf678020731-Sumas-y-Restas-Para-Colorear.pdf
678020731-Sumas-y-Restas-Para-Colorear.pdf
CarlosHernanMontoyab2
 
Model Attribute Check Company Auto Property
Model Attribute  Check Company Auto PropertyModel Attribute  Check Company Auto Property
Model Attribute Check Company Auto Property
Celine George
 
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
siemaillard
 
2024.06.01 Introducing a competency framework for languag learning materials ...
2024.06.01 Introducing a competency framework for languag learning materials ...2024.06.01 Introducing a competency framework for languag learning materials ...
2024.06.01 Introducing a competency framework for languag learning materials ...
Sandy Millin
 
Lapbook sobre os Regimes Totalitários.pdf
Lapbook sobre os Regimes Totalitários.pdfLapbook sobre os Regimes Totalitários.pdf
Lapbook sobre os Regimes Totalitários.pdf
Jean Carlos Nunes Paixão
 
Digital Tools and AI for Teaching Learning and Research
Digital Tools and AI for Teaching Learning and ResearchDigital Tools and AI for Teaching Learning and Research
Digital Tools and AI for Teaching Learning and Research
Vikramjit Singh
 

Recently uploaded (20)

Palestine last event orientationfvgnh .pptx
Palestine last event orientationfvgnh .pptxPalestine last event orientationfvgnh .pptx
Palestine last event orientationfvgnh .pptx
 
A Strategic Approach: GenAI in Education
A Strategic Approach: GenAI in EducationA Strategic Approach: GenAI in Education
A Strategic Approach: GenAI in Education
 
The Challenger.pdf DNHS Official Publication
The Challenger.pdf DNHS Official PublicationThe Challenger.pdf DNHS Official Publication
The Challenger.pdf DNHS Official Publication
 
Honest Reviews of Tim Han LMA Course Program.pptx
Honest Reviews of Tim Han LMA Course Program.pptxHonest Reviews of Tim Han LMA Course Program.pptx
Honest Reviews of Tim Han LMA Course Program.pptx
 
The French Revolution Class 9 Study Material pdf free download
The French Revolution Class 9 Study Material pdf free downloadThe French Revolution Class 9 Study Material pdf free download
The French Revolution Class 9 Study Material pdf free download
 
Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46
Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46
Mule 4.6 & Java 17 Upgrade | MuleSoft Mysore Meetup #46
 
Home assignment II on Spectroscopy 2024 Answers.pdf
Home assignment II on Spectroscopy 2024 Answers.pdfHome assignment II on Spectroscopy 2024 Answers.pdf
Home assignment II on Spectroscopy 2024 Answers.pdf
 
Phrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXX
Phrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXXPhrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXX
Phrasal Verbs.XXXXXXXXXXXXXXXXXXXXXXXXXX
 
Polish students' mobility in the Czech Republic
Polish students' mobility in the Czech RepublicPolish students' mobility in the Czech Republic
Polish students' mobility in the Czech Republic
 
Introduction to AI for Nonprofits with Tapp Network
Introduction to AI for Nonprofits with Tapp NetworkIntroduction to AI for Nonprofits with Tapp Network
Introduction to AI for Nonprofits with Tapp Network
 
Welcome to TechSoup New Member Orientation and Q&A (May 2024).pdf
Welcome to TechSoup   New Member Orientation and Q&A (May 2024).pdfWelcome to TechSoup   New Member Orientation and Q&A (May 2024).pdf
Welcome to TechSoup New Member Orientation and Q&A (May 2024).pdf
 
Overview on Edible Vaccine: Pros & Cons with Mechanism
Overview on Edible Vaccine: Pros & Cons with MechanismOverview on Edible Vaccine: Pros & Cons with Mechanism
Overview on Edible Vaccine: Pros & Cons with Mechanism
 
The geography of Taylor Swift - some ideas
The geography of Taylor Swift - some ideasThe geography of Taylor Swift - some ideas
The geography of Taylor Swift - some ideas
 
Francesca Gottschalk - How can education support child empowerment.pptx
Francesca Gottschalk - How can education support child empowerment.pptxFrancesca Gottschalk - How can education support child empowerment.pptx
Francesca Gottschalk - How can education support child empowerment.pptx
 
678020731-Sumas-y-Restas-Para-Colorear.pdf
678020731-Sumas-y-Restas-Para-Colorear.pdf678020731-Sumas-y-Restas-Para-Colorear.pdf
678020731-Sumas-y-Restas-Para-Colorear.pdf
 
Model Attribute Check Company Auto Property
Model Attribute  Check Company Auto PropertyModel Attribute  Check Company Auto Property
Model Attribute Check Company Auto Property
 
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
 
2024.06.01 Introducing a competency framework for languag learning materials ...
2024.06.01 Introducing a competency framework for languag learning materials ...2024.06.01 Introducing a competency framework for languag learning materials ...
2024.06.01 Introducing a competency framework for languag learning materials ...
 
Lapbook sobre os Regimes Totalitários.pdf
Lapbook sobre os Regimes Totalitários.pdfLapbook sobre os Regimes Totalitários.pdf
Lapbook sobre os Regimes Totalitários.pdf
 
Digital Tools and AI for Teaching Learning and Research
Digital Tools and AI for Teaching Learning and ResearchDigital Tools and AI for Teaching Learning and Research
Digital Tools and AI for Teaching Learning and Research
 

Building science 2 project 1

  • 1. 1 TABLE OF CONTENTS Abstract 1.0 Introduction………………………………………………………………………………….....1 1.1 Aims and Objectives……………………………………………………………………............2 2.0 Precedent Studies…………………………………………………………………………......3 2.1 Lighting Precedent Study……………………………………………………………….......7-10 2.1.1 Solar Decathlon House, Texas 2.2 Acoustic Precedent Study…………………………………………………………………11-16 2.2.1 Yildiz Technical University 2.3 Conclusion………………………………………………………………………………………17 3.0 Research Methodology……………………………………………………………………...18 3.1 Methodology of Lighting Analysis…………………………………………………………….18 3.1.1 Description of Equipment…………………………………………………………….19 3.1.2 Data Collection Method…………………………………………………………...20-21 3.1.3 Lighting Analysis Calculation…………………………………………………......22-23 3.2 Methodology of Acoustic Analysis……………………………………………………………24 3.2.1 Description of Equipment…………………………………………………………24-25 3.1.2 Data Collection Method……………………………………………………………....26 3.1.3 Acoustic Analysis Calculation………………………………………………………..27 4.0 Site Study 4.1 Introduction……………………………………………………………………………………28 4.2 Reason for Selection…………………………………………………………………………29 4.3 Measured Drawings……………………………………………………………………....30-31
  • 2. 2 4.4 Existing Lighting Sources………………………………………………………………….32 4.5 Existing Acoustic Sources…………………………………………………………………33 4.6 Existing Materials on Site……………………………………………………………….....34 4.7 Zoning of Spaces…………………………………………………………………………...35 5.0 Lighting Analysis……………………………………………………………………….....36 5.1 Lighting Lux Readings………………………………………………………………...........36 5.1.1 Daytime Lux Readings…………………………………………………………......36 5.1.2 Night time Lux Readings……………………………………………………….......37 5.1.3 Observation and Discussion……………………………………………………38-39 5.2 Lux Contour Diagram……………………………………………………………………40-41 5.3 Analysis and Calculation……………………………………………………………………42. 5.3.1 Daylight Factor Calculation…………………………………………………………..42 5.3.2 Artificial Light Calculation…………………………………………………………….43 Zone 1: Sitting Area……………………………………………………………..43-45 Zone 2: Outdoor Sitting Area………………………………………………......46-49 Zone 3: Private Gathering Area………………………………………………..50-53 Zone 4: Storage Room 1……..…………………………………………………54-57 Zone 5: Coffee Counter……..…………………………………………………..58-61 Zone 6: Male Toilet ………….………………………………………………….62-65 Zone 7: Female Toilet………………………………………………………......61-63 Zone 8: Sitting Area 2……………………………………………………….... 64-66 Zone 9: Storage Room 2………………………………………………………..67-69 5.4Analysis and Evaluation…………………………………………………………………………70 6.0 Acoustic Analysis 6.1 Noise Sources………………………………………………………………………………...71 6.1.1 External Noise Sources …………………………………………………………….71 6.1.2 Internal Noise Sources………………………………………………………….72- 74
  • 3. 3 6.2 Acoustic Readings…………………………………………………………………………......75 6.2.1 Peak and Non-Peak Hours Readings………………………………………………....75 6.2.2 Observation and Discussion……………………………………………………….....76 6.3 Acoustic Ray Diagram………………………………………………………………………....77 6.4 Analysis and Calculation……………………………………………………………………....78 6.4.1 Equipment Sound Pressure Level……………………………………………….78-81 6.4.2 Sound Pressure Level Calculation……………………………………………....82-86 Zone 1: Sitting Area………………………………………………………………….82 Zone 2: Outdoor Sitting Area……………………………………………………….83 Zone 3: Private Gathering Area…………………………………………………....84. Zone 4: Storage Room 1……..……………………………………………………..85 Zone 5: Coffee Counter……..………………………………………………………86 6.4.3 Spaces Acoustic Analysis………………………………………………………...87-91 6.4.4 Reverberation Time Calculation………………………………………………....92-99 6.4.5 Sound Reduction Index Calculation…………………………………………..100-102 6.5 Analysis and Evaluation…………………………………………………………………....104 8.0 References………………………………………………………………………………105-106 9.0 Appendix………………………………………………………………………………..107- 108
  • 4. 4 Abstract This report contains the details of the study conducted on the Artisan Café with regards to the lighting and acoustical performances. The report is broken down into two main segments Lighting and Acoustics. Included are the technical data such as formulas, equations and calculations that estimate both luminance levels as well as noise levels for both light and acoustic. All orthographic drawings and diagrams were made with data collected from site. The analysis diagrams were made with Autodesk Ecotect, an analysis software.
  • 5. 5 1.0 INTRODUCTION Lighting is one of the major elements when it comes to architecture design, in interior as well as exterior architecture. The texture, colors, solid volumes and enclosed spaces can only be appreciated and enhanced fully when they are lit imaginatively. This project exposes and introduces student to day lighting and artificial lighting requirements in a suggested space. Acoustic design in architecture is an element which the control of sound in spaces is to be concerned especially for enclosed spaces. The requirements vary in relation to different functional spaces. It is essential to preserve and enhance the desired sound and to eliminate noise and undesired sound. This project exposes and introduces students to acoustic design and acoustical requirements in a suggested space. In a group of six, we chose The Artisan Café, located at Petaling Jaya as our site study. We have conducted several visits to our site to ensure the success of our project outcome. Measured drawings, lightings and acoustics measurements as well as photographs have been taken while we were on site. We have also done calculations and analysis to the results of our observations and recordings.
  • 6. 6 1.1 Aims and objectives The aim and objectives of this project is as follows: - To understand the day lighting, lighting and acoustics characteristics - To understand the lighting and acoustic requirements in a suggested place - To determine the characteristics and function of day lighting, artificial lighting, sound and acoustic, within the intended space. - To critically report and analyze the space and suggest remedies to improvise the lighting and acoustic qualities within the space. This project also aims to provide a better understanding on the relationship between the type of materials that are employed in terms of building materials as well as internal furnishings and finishes as well as their impact on acoustical and lighting conditions in the building based on the building’s functions. Understanding the volume and area of each functional space also helps in determining the lighting requirements based on acoustical or lighting inadequacy that is reflected in the data collection. Acknowledging adjacent spaces is also vital to address acoustic concerns. In terms of lighting, specifications of luminaries, height of each type of light as well as the existence of fenestrations will help to understand the lighting conditions within each space. Backed up with precedent studies, drawing comparison with our site study, our precedent studies will aid in determining the different types of lighting and acoustic.
  • 7. 7 2.0 PRECEDENT STUDY 2.1 Lighting Precedent Study Solar Decathlon House, Texas Usa. Figure 2.1.1 : Image of Solar Decathlon House The Solar Decathlon House (SDH) is an interdisciplinary competition project organized by the U.S. Department of Energy where universities around the globe design, construct, and operate fully solar-powered houses. The Design Glare is a major problem in these house whereby due to the floor to ceiling windows surrounding the interior spaces. Based on the characteristics of the light coming through each window in the living room and dining room a calculation of each type of windows and its daylight permeability was done. After the test have been done the house is separated into three different window types. 1. Daylighting Window - Only the sky is visible in the windowst is placed high on the wall and is narrow with a horizontal aspect ratio. The sun’s path is never in the field of view.
  • 8. 8 2. View Window - Both the sky and the ground plane are visible through this window 3. Photovoltaic Panel Window - This window has embedded PV panels to capture energy and block direct sun. Diagram 2.1.1: Floor Plan of Solar Decathlon House Materiality The first step in determining the glare potential of Window 4 was to calculate the reflectance values of all the different materials in the house as well as the materials of the surrounding elements. These values can then be entered into simulation software like Ecotect and Radiance. Reflectance of a material is determined by measuring luminance values. Luminance is how much light your eye (or a sensor) sees after it’s reflected off of a surface. The reflectance value was determined by using a luminance spot meter to measure the luminance of a given surface compared with the luminance of known reference samples (Kodak’s white and grey cards). When taking measurements, the luminous conditions should be as diffuse as possible: no artificial lighting, no daylight at low/high incidence, etc.Using the following formulas, the hemispherical-hemispherical reflectance (ρhh) was calculated for each of the materials in and around the house. ρ1 = ρwhite * (L surface / L white) ρ2 = ρgrey * (L surface / L grey) ρhh = ρ1 + ρ2 /2, with the luminance spot meter targeting the surface to be
  • 9. 9 measured, the surface reflectance value was measured (L surface). That value is then compared with the same reading taken off the white card located in the same spot (L white). Because we know the reflectance of the card (ρwhite), we can calculate the reflectance of the material (ρ1). The procedure is repeated using the grey card, and then the average is calculated. The RGB values of each surface were calculated approximately using Photoshop and pictures from the interior of the room Table 2.1.1 : Materiality Reflectance Table The Light transmittance of a window by measuring luminance values. Illuminance is how much light is coming from a light source. Transmittance is also known as the Visible Light Transmittance (Tvis). To calculate the hemispherical-hemispherical transmittance (Thh) of the windows, the ratio of illuminance of the light after passing through the glazing (lin) is compared with light that bypasses the glazing (lout), where Thh = lin/lout. This measurement needs to be performed under overcast sky conditions. Two luminance meters were used to take measurements inside the room, with the window partially open so it was easy to measure the
  • 10. 10 light that had and had not passed through the glazing. In order to ensure accuracy, the luminance meters were both calibrated and of the same brand and model. The measurements were stopped at the same time and read simultaneously since the sky can vary its luminance every second. Careful attention was paid not to cast any shadows over the luminance meters Diagram 2.1.2 : Analysis Diagram The house was then modeled in Ecotect, translating all the information captured on-site into the model to make it as accurate as possible, including the furniture and the climatic conditions. Within the model, camera views we set-up in the same position as on site. With the Radiance Control Panel, the material surfaces were edited with the correct reflectance value, as well as the correct transmittance taken on site. One challenge encountered was entering the reflectance value of specula objects, such as the polished chrome metal refrigerator, into the 3D model. Radiance cannot accurately represent specula materials that behave like mirrors, since the reflectance will depend on the object being reflecting in the surface.
  • 11. 11 2.2 Acoustic Precedent Study Yildiz Technical University The auditorium hall of Yildiz Technical University (YTU University), The University took its final name in 1992 as Yıldız Technical University located in the central campus is mainly used for congresses, symposium, conferences and various other ceremonies. From time to time, it also host events such as concerts. The hall was renovated in order to increase the audience capacity and eliminate some of its disadvantages, while preserving its general architectural characteristics. Figure 2.2.1 : Yildiz Technical University Auditorium Selection of Interior Surface Materials The effects of materials with different acoustic absorption characteristics on the acoustical environment are proportional to their surface areas. The surface materials chosen to provide the optimum RT for the hall were also assessed with respect to their sizes. Cellular materials for high frequency voices and vibratory panels for low frequency voices were used to obtain a balanced frequency distribution. The purpose of choosing the materials used are briefly explained below.
  • 12. 12 Floors The audience platform was installed with 4mm thickness of felt underlying carper of 8mm thickness; upholstered chairs were used for the seating. In order to allow the sound to reach the audience in the most efficient way, reflective materials are being used for the stage and flooring. Ceilings 8mm thick gypsum boards were used which covered the air conditioning installation. The coffered ceiling was not fully covered with wooden material and was partly left as a hard surface. In order to preserve the architectural elements of the structure itself, the height of the audience platform has been increase Since the height of the space excluded this option from consideration the vertical wooden panels placed around the stage were used to try to meet the need for a reflective surface on and around the stage. Walls 10mm thick wooden panels was considered appropriate in terms of acoustic parameters. Some of the fiber glass-based absorbing materials was placed behind those panels in order to maintain the balance between high and low frequency voices. Pipes and canals for the air conditioning system were hidden by sloped panels covered with fabrics coated with gypsum, especially at the interface of the back wall and the ceiling. The back wall of the hall was furnished with 10 mm wooden panels, which were covered with thick fabrics in order to prevent the generation of an echo.
  • 13. 13 Table 2.2.1:Surface materials in auditorium, their surface area and absorption coefficient (based on Harris, 1994:Cavanaugh & Wilco, 1999) Measurement and Analysis During the revovation of the project, calculation and assessments were carried out on the RT, acoustic level and speech inteligibility parameters. Since 2/3 of the auedience capacity of the space was assumed to be utilized in the RT calculations, both empty and occupied seats were included in the calculation at different absorption values. As speaking intended to be the main use of the hall, the optimum RT range was determined on the basis of the space volume and speech. The changes in RTs calculated by taking the interior surface materials into consideration are shown in table 2. The Rts of the hall, which were measured before renovation, and the RTs obtained from the calculation performed for the empty hall are also included in table 2.3.1.
  • 14. 14 Table 2.2.2 RTs Calculation Sound level measurement were carried out to locate the effects of the interior surface cladding of the space on the BSL. In the unfurnished condition while the air conditioning was operating, the measuremente above were acceptable at all noise frequencies. When the air conditioning was switched off under the same condition, the results were only about 1 dB over the acceptable values at frequencies of 1000 Hz, 2000 Hz and 4000 Hz. On the other hand, the BSLs were always below the acceptable value in the furnished room, both before and after the renovation. Table 2.2.3 : Measured and acceptable BSLs (air conditioning) Particially covering the ceiling with gypsum board and using wooden panels on the walls, significant decays were obrained for RTs at low frequencies after the renovation.
  • 15. 15 Table 2.2.4: Measured, calculated and optimum RTs of YTU auditorium for speech activities. Figure 2.2.2: Section of the YTU auditorium (after renovation)
  • 16. 16 Figure 2.2.3: Plan of YTU auditorium (after renovation)
  • 17. 17 2.3 Conclusion of Precedent Studies 2.3.1 Solar Decathlon House, Texas Solar Decathlon house in Texas is perceived as building flooded with natural light during daytime. The usage of floor to ceiling windows create a vast transparency between outdoor and indoor space, hence allowing maximum permeability of light through it. The study done throughout the day shows a mid range result whereby there are presence of glare during an indefinite period of time and how the reflectance value of the materials effect the results of the analysis. The amount of glare occurrence is being determined through a software whereby projection of thermal quantities is being brought up and analyzed. Resulting from this a data was brought forward and the amount of glare of each windows is calculated. Overall the result shows an amount of unacceptable glare coming from the north portion of the window whereby glazing is present. The result is then being translated and brought up to the users of the home. The Precedent study has gave us an insight of how glazing can enhance and deteriorate the lighting levels of the spaces and how materiality determines the lighting levels of spaces. The importance of daylighting levels during designing is also implemented. 2.3.2 Yildiz Technical University The acoustical properties of the hall have a definite improvement after the renovation being done. The change in the acoustic environment of the hall can be clearly seen due to the use of the different surface material after the renovation. In the study being done for the auditorium the acoustical parameters were being done through the measurements and assessments of the qualities of the surface materials used. Results generated shows the dynamic improvement prior to renovation. The differences in terms of measurements according to analysis done shows that the usage of materials can drastically effect the acoustic qualities of the space. The need for acoustical study prior to construction and build helps designers and engineers determined a space whereby it is conducive for its usage. Overall the precedent done for this auditorium hall has help us gain an insight to the importance of acoustical study prior to design and build as well as the dynamic impact of material usage can change the performance of a building.
  • 18. 18 3.0 RESEARCH METHODOLOGY 3.1 Methodology of Lighting Analysis 3.1.1 Measuring Device: Digital Lux Meter Figure 3.1.1 : digital lux meter Digital Lux Meter is a lightweight electronic device used to measure illumination. This lux meter is provided by Taylors University to aid us in recording data for the intensity of light. General Specifications of Model LX-101 Display 13mm (0.5’’) LCD, 3 ½ digits, Max. indication 1999 Weight 160g/0.36lb (including battery) Dimension Main instrument: 108 x 73 x 23mm Measurement 0 to 50,000 Lux, 3 ranges Power Supply 006P. DC 9V battery, MN 1604 (PP3) or equivalent Current Approx. 2.0mA (D.C) Operating Temperature 0 to 50C (32 to 122F) Over Input Display Indication of ‘’1’’ Zero adjustment Built in external zero adjust VR on front panel Sensor The exclusive photo diode and colour correction filter Standard accessories 1 instruction manual 1 sensor probe 1 carrying case, CA-04
  • 19. 19 Electrical Specifications of Typical Lux Meter Range Resolution Accuracy 0-1,999 Lux 1 Lux ±(5% + 2D)2,000-19,999 Lux 10 Lux 20,000-50,000 Lux 100 Lux 3.1.1.3 Application of Lux Meter (a) The lux meter is switched on (b) The lux meter is switched to a desired range (Resolution chosen : 1Lux) (c) The sensor probe of the lux meter is held facing upwards t specific points according to our 2m gridded floor plan at 1m height. (d) A reading is shown on the display screen of the lux meter (e) The reading is recorded (f) Steps (c), (d) and (e) are repeated by holding the lux meter at 1.5m height, average human eye level. 3.1.1.4 Limitation of Study A lux meter is easy to use and handle. However, there may be some discrepancies in the results when taking readings using a lux meter. - Random Error Human error has been cited as a contributing factor which might affect the readings taken by the lux meter for instance; misreading the data shown on the lux meter. In addition, an inconsistent holding position of the meter might/will affect the data collection. Weather is an unpredictable cause of certain errors as well. For example, during specific data collection time frames, the weather might change from extremely sunny to very cloudy/gloomy
  • 20. 20 and sunny again. Said change will greatly affect readings taken during that time. Additionally, shadows casted on chosen area of recording will also have an impact on the Lux reading. Any glare existent during the recordings will affect the internal lighting measurements. Solutions: Repeat procedures and take several readings at the same height, then calculate the average value which will be more precise. - Systematic Error The instrument might take a few seconds to stabilize the reading due to the sensitivity of the sensor. Readings taken before the value stabilizes might give an inaccurate reading and sometimes there could be a big gap between both readings of a particular position. Solutions: Prepare a stand of respective height and leave it untouched until the measurement stabilises before recording it. 3.1.2 Data Collection Method Measurements are taken at two different times which is 12.00pm and 8pm, one with daylight and the other without. In order to obtain reliable readings, the lux meter was placed at the same height from the floor at each, 1m (waist height) and 1.5m (eye level). Each recording was done by facing towards the similar direction, to synchronize the results. Plans with a perpendicular 2m x 2m gridline were used as a reference guideline, whereby the intersections serve as data recording points. In total there are ### points for lighting and acoustic data collection. Same procedure are repeated for indoor and outdoor for both times.
  • 21. 21 Diagram3.1.1 : Standard height used to record Lux readings Diagram 3.1.2 : 2m x 2m gridlines for recordings
  • 22. 22 3.1.3 Lighting Analysis Calculation Lighting analysis is done by averaging the lux readings of demarcated 9zones based on ms1525. 3.1.3.1 Daylight Factor, DF daylight factor, DF = Einternal / Eexternalx 100 where, Einternal = illuminance due to daylight at a point on the indoor’s working plane Eexternal = direct sunlight = 32,000 lx For example, given that Einternal = 8000lx, hence, daylight factor, DF = Einternal / Eexternalx 100 8000/32000 x 100 = 25 3.1.3.2 Lumen Method The Lumen Method is used to determine the number of lamps that should be installed for a given area or room. In this case, fixtures are already installed, therefore, we are calculating the total luminance of the space based on the number of fixtures and determine whether or not that particular space has enough lighting fixtures. the number of lamps is given by the formula: N = E X A / F X UF X MF where, N = number of lamps required E = luminance level required (lux) A = area at working plane height(m2 ) F = average luminous flux from each lamp (lm) UF = utilization factor, an allowance for the light distribution of the luminaire and the room surfaces MF = maintenance factor, an allowance for the reduced light output because of deterioration and dirt
  • 23. 23 Room Index, RI, is the ratio of room plan area to half the wall area between the working and luminaire planes: RI= L X W / Hm x (L +W) where, L = length of room W = width of room Hm = mounting height, i.e. the vertical distance between the working plane and the luminaries
  • 24. 24 3.2 Methodology of Acoustics Analysis 3.2.1 Measuring Device: Digital Sound Level Meter Figure 3.2.1 : Digital Sound Level Meter A sound level meter is an instrument used to measure sound pressure level, majorly used in noise pollution studies for the quantification of different kinds of acoustics. A digital sound level meter was provided by Taylors University. It was used to collect the acoustics readings at Artisan Café. 3.2.1.1 General Specifications Weight 489g Dimension 254 x 68 x 45 mm Measurement 30 – 130dB Power Supply Alkaline/heavy duty DC 1.5V battery (UM3,AA) x 6pcs Resolution 0.1dB
  • 25. 25 Frequency 31.5 to 8000Hz Features dB (A&C frequency weighting) Time weighting ( Fast, Slow) Peak Hold Data Hold Record (Max., Min.) 3.2.1.2 Application of Digital Sound Level Meter (a) ‘’on/off’’ button is pressed to switch on the device. Display of ‘’Auto Range’’, ‘’A frequency weighing’’ and ‘’Fast time weighing’’ are selected and checked. (b) the sound level meter is held at at 1m height, approximately at waist height. (c) the device is held still and ensure the operator of the device do not produce any sound when using device (d) after all the above procedures are checked, then ‘’HOLD NEXT’’ button is pressed (e) the reading is taken and shown on the display screen. The reading is recorded. (f) Repeat steps (b) to (e) for the next recording position on the grid. 3.2.1.3 Limitation of Study - Human Limitations The digital sound level meter device is very sensitive to its surrounding, with a range of recordings varying between data difference of approximately 0.2-0.3 of stabilisation. Therefore, the data recorded is based on the time seconds when pressing the hold button. Besides, when operating the sound level meter, the device might have been pointed towards the incorrect path of sound source, causing the readings taken to be slightly imprecise. - Sound source stability during the peak hours, sound from all sources such as human activities, noise from music
  • 26. 26 speakers and coffee machines have had a great impact to the acoustic data recorded. During the normal hours, external sounds form surrounding site varies from time to time which affect the data collection as well. 3.1.2 Data Collection Method Readings are recorded at two different times, which is 12pm and 8pm, non-peak and peak hours respectively. In order to acquire the accurate reading, the sound level meter was placed at the same height, 1.5m from floor level at every point. The operator of the device shall not talk and make any noise in order to guarantee reliable sound readings. Each recording was done facing the same direction, again to synchronize the results. Plans with a perpendicular 2m x 2m gridline were used as reference guideline where the intersection points serve as the data recording points. The radings are then tabulated. Same procedure is repeated for both indoor and outdoor. Diagram 3.2.1 : consistent height of reading 1.5m
  • 27. 27 3.1.3 Acoustic Analysis Calculation acoustic analysis is one by categorizing the area into two different zones. The material used, absorption coefficient, area, volume and calculation will be explained zone by zone. 3.2.3.1 Reverberation Time, RT RT is the primary descriptor of an acoustic environment which is used to calculate the reverberation time of an enclosed space. Reverberation time, RT = 0.16 x space volume / total absorption 3.2.3.2 Sound Pressure Level, SPL SPL is the average sound level at a space. Sound Pressure Level, SPL = 10log10 (l/lo(ref) ) where, l = sound power/intensity (watts) lo = reference power (1 x 10-12 watts) 3.2.3.2 Sound Reduction Index, SRI SRI is used to calculate the transmission loss of materials. Sound Reduction Index, SRI = 10log10(1/Tav) where, Tav = (S1 x TC1 + S2 x TC2 +…..+ Sn x TCn ) / TOTAL SURFACE AREA Sn= surface area of material n TCn = Transmission coefficient of material
  • 28. 28 4.0 SITE STUDY 4.1 Introduction Figure 4.1.1 : Interior views of Artisan Cafe Case study : The Artisan Café Type of space : Retro coffee shop Address : Jalan 13/2, Seksyen 13, 46200 Petaling Jaya, Selangor, Malaysia The artisan café is in the heart of Petaling Jaya. The place came to existence when the branched company took over a portion of the old Cherry showroom and converted a warehouse area into the cozy cafe you see today. There are fancy decorations and interesting innovative design ideas to create a raw yet homely feel with wood, concrete and red clay brick. The light fixtures found here are mostly made from recycled materials, for, steel pipes.
  • 29. 29 4.2 Reason for Selection Artisan café has various issues involving lighting and acoustic which relates to the analysis done for this project. In terms of acoustic issues, the site context of the café is mainly an industrial area in Petaling Jaya. This affects the café due to the noise produced in the neighboring context whereby car showrooms and service centers are neighboring the café. The material choice and finishes used in the café also affect the reverberation. Lighting design in artisan café also has its own issues. Due to the café concept to provide a relaxing and subtle environment, the café has employed a lighting design which uses dim lights and it proves to be insufficient. Light Glaring is also an issue faced by the café itself. The front façade of the café is enveloped by glass where direct sunlight could penetrate through, this is counteracted with an adjustable awning installed to provide shading and improve the glare control of the space. Figure4.1.2: Site Context of the Cafe
  • 30. 30 4.3 Measured Drawing Figure 4.1.3 :Ground Floor Plan (N.T.S)
  • 31. 31 Figure 4.1.4 : Mezzanine Floor Plan(N.T.S) Figure 4.1.5 : Sectional Drawing (N.T.S)
  • 32. 32 4.4 Existing Lighting Sources Table 4.1.1 Artifial Lighting Sources
  • 33. 33 4.5 Existing Acoustic Sources Table 4.1.2 Acoustic Sources
  • 34. 34 4.6 Existing Materials on Site Table 4.1.3: Overall material table Component Material Color Surface Finish Reflectance Value (%) Surface Area/ m2 WALL Brick Red Rough 10 20.5 Steel Black Gloss 5 15.45 Plaster White Matte 80 16.32 Plaster Black Matte 4 40 Glass Clear Gloss 8 31.68 ROOF Aluminum Silver Anodized 4 17.28 FLOOR Concrete Grey Matte 15 95.8 CEILING Plaster White Matte 80 95.8 FURNITURE Timber Walnut Matte 10 32.5 MDF Black Matte 5 11.5 Ceramic White Gloss 65 15.5 Fabric Red Matte 12 20.5
  • 35. 35 4.7 Zoning Of Spaces Figure 4.7.1 : Ground Floor Zoning Figure 4.7.2 : Mezzanine Floor Zoning Zone 1 : Sitting Area Zone 7 : Toilet 2 Zone 2 :Outdoor Sitting Area Zone 8 : Seating Area 2 Zone 3 :Private Gathering Area Zone 9 : Storage Room 2 Zone 4 :Storage Room Zone 5 :Coffee Counter Zone 6 :Toilet
  • 36. 36 5.0 LIGHTING ANALYSIS 5.1 Lighting Lux Readings 5.1.1 Daytime Lux Readings Light data (Lux) Day time Ground floor Mezzanine floor Grid Height Grid Height Grid Height 1m 1.5m 1m 1.5m 1m 1.5m A4 926 572 D7 75 81 A8 53 69 B4 928 531 D8 47 62 A9 54 61 C4 468 28 D9 32 27 A10 41 58 D4 301 68 D10 7 11 B8 51 62 E4 208 45 E5 75 50 B9 51 66 F4 201 57 E6 89 75 B10 47 59 G4 211 78 E7 77 64 C9 20 31 H4 191 42 E8 42 65 C10 21 35 A5 30 56 E9 32 29 D9 22 35 A6 52 81 E10 8 12 E9 24 29 A7 70 97 F5 86 52 F9 20 31 B5 120 93 F9 47 65 F10 22 25 B6 102 104 F10 56 78 G6 21 32 B7 98 101 G5 81 55 G7 24 36 C5 104 83 G10 52 79 G8 21 29 C6 61 79 F6 81 70 G9 20 30 C7 57 77 F7 63 78 G10 21 32 A8 53 69 F8 64 79 H6 24 31 A9 11 34 G6 79 54 H7 38 41 A10 8 21 G7 87 113 H8 41 62 B8 63 82 G8 81 109 H9 54 60 B9 56 78 G9 62 80 H10 43 61 B10 17 11 F11 216 318 F11 29 32 C8 42 35 F12 210 301 F12 210 30 C9 41 31 G11 211 321 G11 211 321 C10 21 17 G12 206 311 G12 208 306 D5 108 82 H11 207 301 H11 216 318 D6 87 71 H12 218 321 H12 218 321 Table 5.1.1 Daytime Lux Readings
  • 37. 37 5.1.2 Nighttime Lux Readings Lighting data (Lux) Night time Ground floor Mezzanine floor Grid Height Grid Height Grid Height 1M 1.5M 1M 1.5M 1M 1.5M A4 24 44 D7 14 25 A8 10 15 B4 28 42 D8 12 22 A9 12 16 C4 31 42 D9 10 22 A10 12 17 D4 32 43 D10 12 24 B8 14 19 E4 34 43 E5 14 26 B9 15 22 F4 32 44 E6 16 28 B10 14 18 G4 31 42 E7 12 20 C9 11 20 H4 30 41 E8 10 20 C10 12 21 A5 13 19 E9 11 21 D9 19 21 A6 14 20 E10 12 23 E9 20 19 A7 15 23 F5 15 27 F9 18 21 B5 12 20 F9 12 21 F10 19 20 B6 14 20 F10 10 20 G6 11 20 B7 15 23 G5 14 25 G7 12 21 C5 11 22 G10 10 20 G8 10 20 C6 12 25 H5 15 27 G9 12 22 C7 17 27 H10 11 21 G10 10 21 A8 34 60 F6 18 26 H6 11 20 A9 37 65 F7 16 23 H7 10 20 A10 35 62 F8 14 24 H8 11 21 B8 35 64 G6 20 28 H9 10 20 B9 39 67 G7 15 21 H10 10 21 B10 34 63 G8 12 22 F11 10 21 C8 27 24 G9 10 23 F12 12 23 C9 15 20 H6 19 29 G11 10 21 C10 13 21 H7 14 21 G12 11 20 D5 20 37 H8 13 21 H11 129 175 D6 18 35 H9 11 22 H12 125 170 F11 10 21 F12 12 24 G11 10 22 G12 11 21 H11 127 172 H12 128 167 Table 5.1.2 Nightime Lux Readings
  • 38. 38 5.1.3 Observation and Discussion Based on the lighting data table above, the following observations were noted along with relevant discussions. Observation 1: Both light data collected during the day and night are lower than the recommended lux level by MS 1525. Discussion 1: This is due to the owner trying to achieve the desired ambience and environment in the café. Observation 2: Light data collected at a level of 1.5m above ground level are higher than the readings taken at a level of 1m above ground Discussion 2: This is due to the proximity of the lux meter to the artificial light source. At a level of 1.5m, the lux meter is close to the source, thus it receives a higher lux reading as compared to the reading taken at a level of 1m above ground. Observation 3: Lux readings in the toilet areas (ZONE 6 & ZONE 7) are relatively high as compared to other spaces. Discussion 3: This is due to the ample amount of light sources in the relatively small area.
  • 39. 39 Figure 5.1.1: Artificial Light Diagram The figure above illustrates the lighting rays of different artificial lighting used in Artisan Cafe. The sitting area of the cafe has a really low light level due to the low intensity lamps used. The sitting area uses wall lighting and pendant lighting as the source of artificial lighting. This creates a really dark environment whereby it relates to the theme of the cafe itself. There are no presence of down light or spotlights in the sitting area of the cafe. However, the toilets are lighted up by LED spotlights, used to increase the brightness of the space. Figure 5.1.2: Natural Light Diagram The figure above indicates the source of natural lighting throughout the interior spaces of the cafe. Due to the facade of the building being glass, natural lighting penetration is ample throughout the space. However due to glare the cafe fitted blinds and retractable awnings on the windows and outdoor area solve this matter.
  • 40. 40 5.2 Lux Contour Diagram Diagram 5.2.1 Daylight Lux Contour Diagram
  • 41. 41 Diagram 5.2.2 Artificial Lux Contour Diagram
  • 42. 42 5.3 Analysis and Calculation 5.3.1 Daylight Factor Calculation Time/ Date/ Sky Condition Zone Daylight Level in Malaysia Eo (lux) Average Lux reading Ei (lux) Daylight Factor, DF DF = (Ei / Eo) X 100% 11th April 2014 12.30 PM Sunny Zone 1 32000 75.92 DF = (Ei / Eo) X 100% DF = (75.92 / 32000) X100% 0.24% Zone 2 303.44 DF = (Ei / Eo) X 100% DF = (303.44 / 32000) X100% 0.95% Zone 3 80.42 DF = (Ei / Eo) X 100% DF = (80.42 / 32000) X100% 0.25%
  • 43. 43 5.3.2 Artificial Light Calculation Zone 1: Sitting Area Figure 5.3.1 Sitting Area Light Indicator Plan Table 5.3.1 Lighting Specifications
  • 44. 44 Table 5.3.2 : Zone 1 Material Table Component Material Colour Surface Finish Reflectance Value (%) Surface Area/ m2 WALL Brick Red Rough 10 20.5 Plaster White Matte 80 16.32 Plaster Black Matte 4 40 Glass Clear Gloss 8 31.68 FLOOR Concrete Grey Matte 15 95.8 CEILING Plaster White Matte 80 95.8 FURNITURE Timber Walnut Matte 10 15.4 Ceramic White Gloss 65 5.6 Fabric Red Matte 12 20.9
  • 45. 45 A B C Width of Room 5.7 5.7 5.4 2.3 Length of room 8 8 6 3.8 Dimension of Room ( L x W ) 45.6 45.6 32.4 8.74 Total floor Area / A 86.74 Type of lighting fixture Vintage Edison Vintage Edison LED Spotlight Number of lighting fixture / N 3 2 3 1 Lumen of lighting fixture / F (lux) 310 310 310 325 Height of luminaire (m) 1.7 1.7 1.9 2.3 Height of work level (m) 0.8 0.8 0.8 0.8 Mounting height / H (m) 1.1 0.9 0.9 1.5 Assumption of Reflectance value Wall 0.8/Ceiling 0.8/Floor 0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 3.03 3.70 3.16 0.96 Utilization Factor / UF 0.54 0.54 0.54 0.43 Based on given utilization factor table Maintenance Factor / MF 0.8 0.8 0.8 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 4.63 3.09 4.63 1.29 Total Illuminance 13.64 Table 5.3.4 : Zone 1 Calculation Table
  • 46. 46 Zone 2: Outdoor Sitting Area Figure 5.3.2: Outdoor Sitting Area Light Indicator Plan Table 5.3.4 : Lighting Specifications
  • 47. 47 Table 5.3.5 : Zone 2 Material Table Component Material Colour Surface Finish Reflectance Value (%) Surface Area/m2 WALL Glass Clear Gloss 8 47.83 Aluminu m Silver Anodiz ed 55 24.3 Plaster White Matte 80 24.32 FLOOR Brick Red Matte 10 114 CEILING Canvas Black Matte 4 50.4 Plaster Black Matte 4 55.6 FURNITURE Timber Walnut Matte 10 43.6
  • 48. 48 Width of Room 4 Length of room 15 Dimension of Room ( L x W ) 60 Total floor Area / A 60 Type of lighting fixture LED Spotlight Number of lighting fixture / N 6 Lumen of lighting fixture / F (lux) 325 Height of luminaire (m) 2.8 Height of work level (m) 0.8 Mounting height / H (m) 2 Assumption of Reflectance value Wall0.5/Ceiling0.5/Floor0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 1.58 Utilization Factor / UF 0.43 Based on given utilization factor table Maintenance Factor / MF 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 11.18 Total Illuminance 11.18 Table 5.3.6 : Zone 2 Calculation Table
  • 49. 49 Zone 3: Private Gathering Area Figure 5.3.4: Private Gathering Area Light Indicator Plan Table 5.3.7 : Lighting Specifications
  • 50. 50 Table 5.3.8 : Zone 3 Material Table Component Material Colour Surfa ce Finish Reflectanc e Value (%) Surface Area/ m2 WALL Glass Clear Gloss 8 12.7 Aluminum Silver Anodi zed 55 11.6 Plaster Black Matte 4 17.28 Steel Black Gloss 5 5.43 FLOOR Concrete Grey Matte 15 26.4 CEILING Plaster Black Matte 80 26.4 FURNITURE Timber Walnut Matte 10 22.4
  • 51. 51 A B Width of Room 4.9 4.9 Length of room 5.4 5.4 Dimension of Room ( L x W ) 26.46 26.46 Total floor Area / A 26.46 26.46 Type of lighting fixture Vintage Edison Philips Compact Halogen Bulb Number of lighting fixture / N 4 3 Lumen of lighting fixture / F (lux) 325 900 Height of luminaire (m) 1.9 3 Height of work level (m) 0.8 0.8 Mounting height / H (m) 1.1 2.2 Assumption of Reflectance value Wall0.8/Ceiling0.5/Floor0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 2.34 1.17 Utilization Factor / UF 0.55 0.47 Based on given utilization factor table Maintenance Factor / MF 0.8 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 21.62 38.37 Total Illuminance 59.98 Table 5.3.9 : Zone 3 Calculation Table
  • 52. 52 Zone 4: Storage Room 1 Figure 5.3.5: Storage Room Light Indicator Plan Table 5.3.9 : Lighting Specifications
  • 53. 53 Table 5.3.10 : Zone 4 Material Table Component Material Colour Surface Finish Reflectan ce Value (%) Surface Area/ m2 WALL Glass Clear Gloss 8 23.2 Plaster Black Matte 4 40.96 FLOOR Concrete Grey Matte 15 13.44 CEILING AC sheet Black Matte 4 13.44 FURNITURE Timber Walnut Matte 10 11.1
  • 54. 54 Width of Room 2.84 Length of room 4.8 Dimension of Room ( L x W ) 13.68 Total floor Area / A 13.68 Type of lighting fixture Fluorescent Light Number of lighting fixture / N 2 Lumen of lighting fixture / F (lux) 1200 Height of luminaire (m) 1.9 Height of work level (m) 0.8 Mounting height / H (m) 1.1 Assumption of Reflectance value Wall0.3/Ceiling0.3/Floor0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 1.63 Utilization Factor / UF 0.4 Based on given utilization factor table Maintenance Factor / MF 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 56.14 Total Illuminance 56.14 Table 5.3.11 : Zone 4 Calculation Table
  • 55. 55 Zone 5: Coffee Counter Figure 5.3.5: Coffee Counter Light Indicator Plan Table 5.3.12 : Lighting Specifications
  • 56. 56 Table 5.3.13 : Zone 5 Material Table Component Material Colour Surfa ce Finish Reflectanc e Value (%) Surface Area/ m2 WALL Glass Clear Gloss 8 12.7 Plaster White Matte 80 17.28 FLOOR Concrete Grey Matte 15 26.4 CEILING Metal Black Matte 4 26.4 FURNITURE Timber Walnut Matte 10 21.6 MDF Black Matte 5 11.54
  • 57. 57 Width of Room 3.8 Length of room 6.1 Dimension of Room ( L x W ) 23.18 Total floor Area / A 23.18 Type of lighting fixture LED Spotlight Number of lighting fixture / N 14 Lumen of lighting fixture / F (lux) 325 Height of luminaire (m) 2.8 Height of work level (m) 0.8 Mounting height / H (m) 2 Assumption of Reflectance value Wall0.8/Ceiling0.3/Floor0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 1.17 Utilization Factor / UF 0.38 Based on given utilization factor table Maintenance Factor / MF 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 59.67 Total Illuminance 59.67 Table 5.3.14 : Zone 5 Calculation Table
  • 58. 58 Zone 6: Male Toilet Figure 5.3.6: Male toilet Light Indicator Plan Table 5.3.15 : Lighting Specifications
  • 59. 59 Table 5.3.16 : Zone 6 Material Table Component Material Colour Surface Finish Reflectan ce Value (%) Surface Area/ m2 WALL Ceramic White Gloss 65 12.8 Plaster Black Matte 4 40.64 FLOOR Concrete Grey Matte 15 13.4 CEILING AC sheet Black Matte 4 13.44 FURNITURE Mirror Reflectiv e Gloss 100 21.4 Porcelain White Gloss 75 11.1
  • 60. 60 Width of Room 4 Length of room 3.35 Dimension of Room ( L x W ) 13.4 Total floor Area / A 13.4 Type of lighting fixture LED Bulb (Recessed) Number of lighting fixture / N 6 Lumen of lighting fixture / F (lux) 380 Height of luminaire (m) 1.6 Height of work level (m) 0.8 Mounting height / H (m) 0.8 Assumption of Reflectance value Wall0.5/Ceiling0.3/Floor0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 2.28 Utilization Factor / UF 0.44 Based on given utilization factor table Maintenance Factor / MF 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 59.89 Total Illuminance 59.89 Table 5.3.17 : Zone 6 Calculation Table
  • 61. 61 Zone 7: Female Toilet Figure 5.3.7: Female toilet Light Indicator Plan Table 5.3.18 : Lighting Specifications
  • 62. 62 Table 5.3.19 : Zone 7 Material Table Component Material Colour Surface Finish Reflectan ce Value (%) Surface Area/ m2 WALL Ceramic White Gloss 65 12.8 Plaster Black Matte 4 40.64 FLOOR Concrete Grey Matte 15 13.4 CEILING AC sheet Black Matte 4 13.44 FURNITURE Mirror Reflectiv e Gloss 100 13.6 Porcelain White Gloss 75 5.2
  • 63. 63 Width of Room 4 Length of room 3.35 Dimension of Room ( L x W ) 13.4 Total floor Area / A 13.4 Type of lighting fixture LED Bulb (Recessed) Number of lighting fixture / N 6 Lumen of lighting fixture / F (lux) 380 Height of luminaire (m) 1.7 Height of work level (m) 0.8 Mounting height / H (m) 0.9 Assumption of Reflectance value Wall0.7/Ceiling0.5/Floor0.2 Room Index / RI (K) RI= L x W ( L + W ) x H 2.03 Utilization Factor / UF 0.53 Based on given utilization factor table Maintenance Factor / MF 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 72.14 Total Illuminance 72.14 Table 5.3.20 : Zone 7 Calculation Table
  • 64. 64 Zone 8: Sitting Area 2 Figure 5.3.8: Sitting Area 2 Light Indicator Plan Table 5.3.21 : Lighting Specifications
  • 65. 65 Table 5.3.22 : Zone 8 Material Table Component Material Colour Surface Finish Reflectan ce Value (%) Surface Area/ m2 WALL Plaster White Matte 80 55.4 Plaster Black Matte 4 62.4 Steel Black Matte 4 34.5 Brick Red Rough 10 67.4 FLOOR Fiber board Grey Matte 15 13.4 CEILING Plaster White Matte 80 13.4 FURNITURE Timber Walnut Matte 10 32.3 Fabric Red Matte 12 20.1
  • 66. 66 A B Width of Room 3.4 2.85 Length of room 9.15 4.8 Dimension of Room ( L x W ) 31.11 213.68 Total floor Area / A 31.11 213.68 Type of lighting fixture Bulbrite 100W Glove Bulb Bulbrite 100W Glove Bulb Number of lighting fixture / N 5 3 Lumen of lighting fixture / F (lux) 580 580 Height of luminaire (m) 1.8 1.8 Height of work level (m) 0.8 0.8 Mounting height / H (m) 1 1 Assumption of Reflectance value Wall0.8/Ceiling0.8/Floor0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 2.48 1.79 Utilization Factor / UF 0.53 0.5 Based on given utilization factor table Maintenance Factor / MF 0.8 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 39.52 50.88 Total Illuminance 90.40 Table 5.3.23 : Zone 8 Calculation Table
  • 67. 67 Zone 9: Storage Area 2 Figure 5.3.9: Storage Room 2 Light Indicator Plan Table 5.3.24 : Lighting Specifications
  • 68. 68 Table 5.3.25 : Zone 9 Material Table Component Material Colour Surface Finish Reflectan ce Value (%) Surface Area/ m2 WALL Plaster White Matte 80 4.8 Plaster Black Matte 4 2.3 Steel Black Matte 4 4.5 Brick Red Rough 10 5.6 FLOOR Fiber board Grey Matte 15 13.4 CEILING Plaster White Matte 80 13.4 FURNITURE Timber Walnut Matte 10 7.9 Fabric Red Matte 12 3.0
  • 69. 69 A B Width of Room 2.85 2.85 Length of room 4.8 4.8 Dimension of Room ( L x W ) 13.68 13.68 Total floor Area / A 13.68 13.68 Type of lighting fixture Vintage Edison Halogen bulb Number of lighting fixture / N 2 3 Lumen of lighting fixture / F (lux) 310 900 Height of luminaire (m) 1.6 1.6 Height of work level (m) 0.8 0.8 Mounting height / H (m) 0.8 0.8 Assumption of Reflectance value Wall0.8/Ceiling0.8/Floor0.1 Room Index / RI (K) RI= L x W ( L + W ) x H 2.24 2.24 Utilization Factor / UF 0.51 0.51 Based on given utilization factor table Maintenance Factor / MF 0.8 0.8 Standard Illuminance (lux) Iluminance level (lux) E = N x F x UF x MF A 18.49 53.68 Total Illuminance 72.18 Table 5.3.26 : Zone 9 Calculation Table
  • 70. 70 5.4 Analysis and Evaluation Lighting is important within restaurants and cafes, especially feature lighting that creates ambience and mood. The different types of lighting fixtures found inside the Artisan Cafe offers different illumination levels. From our observation on site, pendant lighting is the dominant type of lighting fixture at the first floor of the café. It is used mainly to illuminate the tables at the main and private seating area, as well as the seating areas at the mezzanine floor. However at the coffee counter area, track spotlights are being used instead, to illuminate the menus hanged above the counters. Unlike pendant lighting that uniformly distributes illumination, spotlighting only illuminates the spot at which it is directed. Spaces in which these lights are not pointed at are usually inadequately lit up. Based on our data collection, the space inside the café is considered to be rather dark during the day, despite having large glass entrance. It is mainly due to the large black canvas roof covering the outdoor seating area, and most of the interior pendant lights are switched off during the day. Referring to the precedent study on lighting analysis, the Solar Decathlon House utilizes daylighting and countermeasures against glare from sunlight. This predicts the result of using daylighting and how it affects the ambience of a space. Most of the lux readings on our site are below the lux requirements for each space during daytime due to the interior lights not being utilized. Even during the nighttime with all the lights turned on, the readings are still below lux requirements. However, it is the intention for the café to have a somewhat dim ambience to create that cool and cozy environment in the café. Natural lighting is only available to penetrate inside the building to the main sitting area and the private sitting area, due to both areas are the closest to the glass walls of the entrance. In conclusion, it may be the designer to have the café to be dimly lit to achieve a certain character and ambience however, the requirements set by MS 1525 must be taken into consideration when it comes lighting design not only to achieve the desired atmosphere but as well as visual comfort.
  • 71. 71 6.0 ACOUSTIC ANALYSIS 6.1 Noise Sources 6.1.1 External Noise Sources Figure 6.1.1: Location of Site in relation to main road The site is facing a trunk road Jalan 13/2. The road is moderately busy during non-peak hours and peak hours. The main outdoor noise sources are coming from the construction site located opposite the site and beside the site. Due to the typology of the site being and industrial zone, factory activities is also one of the contributors of outdoor noises. Apart from these noises vehicular noise present nearby the construction zones also create an impact towards the cafe.
  • 72. 72 6.1.2 Internal noise sources Air Circulators Figure 6.1.2: Placement of Air Circulators Air conditioners are placed in the interior space of the cafe as a form of artificial ventilation. Fans are also present in the space to compliment the usage of mechanical ventilation. The noise produced by these equipment has a low effect towards the acoustic values due to the nature of the site as a cafe whereby the noise frequency is outnumbered by the human activity. However when the cafe closes a certain acoustical value can be captured in the space itself.
  • 73. 73 Human Activity Figure 6.1.3: Human activity points Concentration of human activities in the cafe varies throughout the day. During peak hour, the amount of human activities increases therefore there is a jump in reading. Customers having discussion and chats are the main factor. However the sound of coffee preparation is also a major acoustic value contributor due to the nature of the coffee machine located at Zone 5.
  • 74. 74 Audio Equipment Figure 6.1.4: Position of Speakers Speakers are located throughout the cafe. The speakers are turned on in a low volume to create a soothing atmosphere while maintaining a conversation free zone. The music played throughout the day are mellow and slow therefore there are really little contribution from the speakers. Speakers also helps create a reverberation from the sound generated from the human activity and neutralizes the impact from it.
  • 75. 75 6.2 Acoustic Readings Table 6.2.1 Peak and Non - Peak Hours Readings Acoustic data Day time Ground floor Mezzanine floor Grid Acoustic Grid Acoustic Grid Acoustic Peak Non-peak Peak Non-peak Peak Non-peak A4 79 67 D7 75 62 A8 57 31 B4 76 65 D8 73 63 A9 60 32 C4 80 63 D9 71 61 A10 58 43 D4 85 64 D10 77 68 B8 57 33 E4 86 63 E5 80 69 B9 59 32 F4 77 62 E6 73 63 B10 60 34 G4 80 64 E7 73 63 C9 75 61 H4 78 65 E8 76 65 C10 79 65 A5 77 55 E9 73 62 D9 77 63 A6 70 57 E10 80 70 E9 75 63 A7 66 43 F5 64 53 F9 77 63 B5 73 54 F9 78 65 F10 77 70 B6 72 58 F10 77 70 G6 77 66 B7 69 40 G5 63 42 G7 75 61 C5 74 55 G10 82 70 G8 74 61 C6 74 53 H5 64 49 G9 71 60 C7 73 51 H10 86 74 G10 68 58 A8 59 32 F6 70 63 H6 74 63 A9 66 34 F7 80 71 H7 74 62 A10 59 33 F8 82 70 H8 73 63 B8 57 32 G6 79 65 H9 71 60 B9 59 34 G7 85 73 H10 68 59 B10 57 32 G8 85 71 F11 66 54 C8 73 67 G9 86 71 F12 68 58 C9 74 65 H6 76 63 G11 65 53 C10 74 63 H7 84 74 G12 67 56 D5 77 60 H8 84 72 H11 68 58 D6 75 63 H9 83 75 H12 69 59 F11 66 57 F12 67 57 G11 68 56 G12 65 56 H11 65 56 H12 64 57
  • 76. 76 6.2 Observation and Discussion Based on the noise level data table above, the following observations were noted along with relevant discussions. Observation 1: The average noise level data collected during peak hours are higher compared to the data collected during non-peak hours. Discussion 1: This is due to the larger number of occupants in the building during peak hours that contributes to the increase of noise levels. The coffee grinders are also utilized from time to time, which may affect the noise level. Observation 2: The noise reading levels during peak and non-peak in the main and private sitting areas are averagely similar. Discussion 2: This is due to the areas sharing the same open space, only divided by a partition. Observation 3: The average reading levels during peak and non-peak hours at the coffee counter are the highest compared to other zones. Discussion 3: This is due to the utilization of coffee grinders which affects the noise level readings.
  • 77. 77 6.3 Acoustic Ray Diagrams Figure 6.3.1: Acoustic Ray Diagram
  • 78. 78 6.4 Analysis and Calculation 6.4.1 Equipment Sound Pressure Level Calculation for speakers Sound pressure level (SPL) = 10log (I/Iref) IhereI = sound power (watt) Iref = reference power (10-12 ) Number of speakers in Artisan coffee HQ (indoor) = 5 Number of Speakers in Artisan Coffee HQ (outdoor) = 2 One speaker produces approximately 80 dB Therefore, SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 80/10 X 10-12 I= 108 X 10-12 I= 10-4 Total number of speakers indoor = 5 Total intensity = 5 x 10-4 Therefore, combined SPL indoor = 10log (I / Iref) = 10log (5 x 10-4 / 1 X 10-12 ) = 86.99 dB Therefore, combined SPL outdoor = 10log (I / Iref) = 10log (2 x 10-4 / 1 X 10-12 ) = 83.01 dB
  • 79. 79 Calculation for Air conditioner Number of Air Conditioner in Artisan Coffee HQ = 6 One Air Conditioner produces approximately 40 dB Therefore, SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 40/10 X 10-12 I= 104 X 10-12 I= 10-8 Total number of air conditioner= 6 Total intensity = 6 x 10-8 Therefore, combined SPL = 10log (I / Iref) = 10log (6 x 10-8 / 1 X 10-12 ) = 47.78 dB
  • 80. 80 Calculation for ceiling fan Number of ceiling fan in Artisan coffee HQ (indoor) = 1 Number of ceiling fan in Artisan Coffee HQ (outdoor) = 2 One ceiling fan produces approximately 50 dB Therefore, SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 50/10 X 10-12 I= 105 X 10-12 I= 10-7 Total number of ceiling fan indoor = 1 Total number of ceiling fan outdoor = 2 Total intensity = 1 x 10-7 Therefore, combined SPL indoor = 10log (I / Iref) = 10log (1 x 10-7 / 1 X 10-12 ) = 50 dB Therefore, combined SPL outdoor = 10log (I / Iref) = 10log (2 x 10-4 / 1 X 10-12 ) = 53.01 dB Calculation for coffee maker Number of coffee maker in Artisan Coffee HQ = 1 One coffee maker produces approximately 70 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref
  • 81. 81 I= 10 70/10 X 10-12 I= 107 X 10-12 I= 10-5 Calculation for exhaust fan Number of exhaust fan in Artisan Coffee HQ = 4 One exhaust fan produces approximately 60 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 60/10 X 10-12 I= 106 X 10-12 I= 10-6 Therefore, combined SPL = 10log (I / Iref) = 10log (4 x 10-6 / 1 X 10-12 ) = 66.02 dB zone 3 =1 speaker 1 aircon zone 4 = 1 aircon zone 5 = 1 coffee machine sound power of speaker = 10-4 Air conditioner = 10-8 Fan = 10-7 Coffee Machine =10-5 Exhaust Fan = 10-6
  • 82. 82 6.4.2 Sound Pressure Level Calculation Zone 1: Sitting Area Figure 6.4.2.1 : Zone 1 Acoustic Equipment 4 speakers 1 ceiling fan 4 air conditioner Total Intensities = (4 X 10-4 ) + 10-7 + (4 X 10-8 ) =4 X 10-4 SPL (dB) = 10log (I / Iref) = 10log ((4 X 10-4 ) / 10-12 ) =86.02 dB
  • 83. 83 Zone 2 : Outdoor Sitting Area Figure 6.4.2.2 : Zone 2 Acoustic Equipment Zone 2 2 fan 2 speakers Total Intensities = (2 X 10-7 ) + (2 X 10-4 ) =2 X 10-4 SPL (dB) = 10log (I / Iref) = 10log ((2 X 10-4 ) / 10-12 ) =83.01 dB
  • 84. 84 Zone 3 : Private Gathering Area Figure 6.4.2.3 : Zone 3 Acoustic Equipment Zone 3 1 speaker 1 aircon Total Intensities = (1 X 10-8 ) + (1 X 10-4 ) =1 X 10-4 SPL (dB) = 10log (I / Iref) = 10log ((1 X 10-4 ) / 10-12 ) =80 dB
  • 85. 85 Zone 4 : Storage Room Figure 6.4.2.4 : Zone 4 Acoustic Equipment Zone 4 1 aircon Total Intensities = 1 X 10-8 SPL (dB) = 10log (I / Iref) = 10log ((1 X 10-8 ) / 10-12 ) =40 dB
  • 86. 86 Zone 5 : Coffee Counter Figure 6.4.2.5 : Zone 5 Acoustic Equipment Zone 5 1 coffee machine Total Intensities = 1 X 10-5 SPL (dB) = 10log (I / Iref) = 10log ((1 X 10-5 ) / 10-12 ) =70 dB
  • 87. 87 6.4.3 Spaces Acoustic Analysis Zone 2 - Outdoor sitting area Non-peak hour Highest reading: 67 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 67/10 X 10-12 I= 106.7 X 10-12 I= 10-5.3 Lowest reading: 62 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 62/10 X 10-12 I= 106.2 X 10-12 I= 10-5.8 Total Intensities, I = (1 x 10-5.3 ) + (1 x 10-5.8 ) = 6.6 x 10-6 SPL = 10log (I / Iref) = 10log (6.6 x 10-6 / 1 X 10-12 ) = 68.2 dB Peak Hour Highest reading: 86 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 86/10 X 10-12 I= 108.6 X 10-12 I= 10-3.4 Lowest reading: 77 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 77/10 X 10-12 I= 107.7 X 10-12 I= 10-4.3
  • 88. 88 Total Intensities, I = (1 x 10-3.4 ) + (1 x 10-4.3 ) = 4.48 x 10-4 SPL = 10log (I / Iref) = 10log (4.48 x 10-4 / 1 X 10-12 ) = 86.51 dB Zone 4 - Storage Room Non-peak hour Highest reading: 34 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 34/10 X 10-12 I= 103.4 X 10-12 I= 10-8,6 Lowest reading: 32 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 32/10 X 10-12 I= 103.2 X 10-12 I= 10-8.8 Total Intensities, I = (1 x 10-8.6 ) + (1 x 10-8.8 ) = 4.09 x 10-9 SPL = 10log (I / Iref) = 10log (4.09 x 10-9 / 1 X 10-12 ) = 36.12 dB Peak Hour Highest reading: 66 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 66/10 X 10-12 I= 106.6 X 10-12 I= 10-5.4 Lowest reading: 57 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 57/10 X 10-12 I= 105.7 X 10-12 I= 10-6.3
  • 89. 89 Total Intensities, I = (1 x 10-5.4 ) + (1 x 10-6.3 ) = 4.48 x 10-6 SPL = 10log (I / Iref) = 10log (4.48 x 10-6 / 1 X 10-12 ) = 66.51 dB Zone 1 - Sitting Area Non-peak hour Highest reading: 74 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 74/10 X 10-12 I= 107.4 X 10-12 I= 10-5.6 Lowest reading: 42 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 42/10 X 10-12 I= 104.2 X 10-12 I= 10-7.8 Total Intensities, I = (1 x 10-5.6 ) + (1 x 10-7.8 ) = 2.53 x 10-6 SPL = 10log (I / Iref) = 10log (2.53 x 10-6 / 1 X 10-12 ) = 64.03 dB Peak Hour Highest reading: 86 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 86/10 X 10-12 I= 108.6 X 10-12 I= 10-3.4 Lowest reading: 64 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 64/10 X 10-12 I= 106.4 X 10-12 I= 10-5.6
  • 90. 90 Total Intensities, I = (1 x 10-3.4 ) + (1 x 10-5.6 ) = 4 x 10-4 SPL = 10log (I / Iref) = 10log (4 x 10-4 / 1 X 10-12 ) = 86.03 dB Zone 5 - Coffee Counter Non-peak hour Highest reading: 75 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 75/10 X 10-12 I= 107.5 X 10-12 I= 10-5.5 Lowest reading: 63 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 63/10 X 10-12 I= 106.3 X 10-12 I= 10-5.4 Total Intensities, I = (1 x 10-5.5 ) + (1 x 10-5.4 ) = 7.14 x 10-6 SPL = 10log (I / Iref) = 10log (7.14 x 10-6 / 1 X 10-12 ) = 68.54 dB Peak Hour Highest reading: 86 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 86/10 X 10-12 I= 108.6 X 10-12 I= 10-3.4 Lowest reading: 70 dB SPL (dB) = 10log (I / Iref) I = 10dB/10 X Iref I= 10 70/10 X 10-12 I= 107 X 10-12 I= 10-5
  • 91. 91 Total Intensities, I = (1 x 10-3.4 ) + (1 x 10-5 ) = 4.08 x 10-4 SPL = 10log (I / Iref) = 10log (4.08 x 10-4 / 1 X 10-12 ) = 86.11 dB
  • 92. 92 6.4.4 Reverberation Time Calculation Reverberation time is calculated to determine the amount of sound energy that is absorbed into the different types of construction materials in the structure as well as the interior elements such as building occupants and furniture that are housed within this closed space. The Reverberation time can be calculated by using Sabine's Equation: RT60 = (0.16 X V) / A where RT60 is the time taken for the noise to drop 60dB below original level (known as Reverberation Time), V is volume of the enclosure, and A being the absorption coefficient of the total area. Calculated Space Seating area (Zone 1) + Cafe bar (Zone 5) + Mezzanine Floor (Zone 1) Reverberation times are calculated based on different material absorption coefficient at 500Hz, 2000Hz and 4000Hz for peak and non-peak hours. - Material Absorption Coefficient at 500Hz for non-peak hours. - Material Absorption Coefficient at 2000Hz for non-peak hours. - Material Absorption Coefficient at 4000Hz for non-peak hours. - Material Absorption Coefficient at 500Hz for peak hours. - Material Absorption Coefficient at 2000Hz for peak hours. - Material Absorption Coefficient at 4000Hz for peak hours. Volume of calculated space = 5.7m X [(11.85m X 5.73m) + (10m X 5.5m)] = 700.53m3
  • 93. 93 Reverberation Time at 500Hz / Non-Peak Hour Table 6.4.4.1 : Reverberation Time at 500Hz RT60 = (0.16 X V) / A = (0.16 X 700.53) / 45.3507 = 2.47s Component Material Function Area(m2 ) [A]/ Quantity Absorption Coefficient [S] Sound Absorption [SA] Ceiling Plaster (Gypsum Board, Smooth finish on lath) Ceiling 122.29 0.06 7.3374 Steel (Painted) Mezzanine Truss 14.84 0.44 6.5296 Wall Brick (Unglazed) Wall 38.3 0.03 1.149 Plaster (White, Smooth finish on brick) Wall 16.32 0.02 0.3264 Plaster (Black, Smooth finish on brick) Wall 105.05 0.02 2.101 Glass (Large pane) Fixed-Panel 52.91 0.04 2.1164 Openings Glass (Large Pane) Pivot Door 3.52 0.04 0.1408 Timber (Plywood) Pivot Door 4.4 0.15 0.66 Steel (Painted) Folding Door 2.2 0.44 0.968 Floor Concrete Screed Floor 122.29 0.015 1.83435 FiberBoard Mezzanine Floor 38.77 0.06 2.3262 Furniture Timber Table, Chair 5.87 0.15 0.8805 Timber Cupboard 5.8 0.05 0.29 Ceramic Countertop 6.54 0.01 0.0654 Concrete screed Counter 44.43 0.015 0.66645 Fabric Sofa 7.96 0.77 6.1292 MDF Sofa 13.3 0.1 1.33 People (Non- Peak Hour) 25 0.42 10.5 Total Absorption [A] 45.3507 The reverberation time for the cafe at 500Hz during non-peak hours is 2.47 seconds which is adequately within the intended 1.5 – 2.5 seconds for public space that requires both speech and music activities.
  • 94. 94 Reverberation Time at 2000Hz / Non-Peak Hour Table 6.4.4.2 : Reverberation Time at 2000Hz RT60 = (0.16 X V) / A = (0.16 X 700.53) / 47.0248 = 2.38s Component Material Function Area(m2 ) [A]/ Quantity Absorption Coefficient [S] Sound Absorption [SA] Ceiling Plaster (Gypsum Board, Smooth finish on lath) Ceiling 122.29 0.04 4.8916 Steel (Painted) Mezzanine Truss 14.84 0.54 8.0136 Wall Brick (Unglazed) Wall 38.3 0.05 1.915 Plaster (White, Smooth finish on brick) Wall 16.32 0.02 0.3264 Plaster (Black, Smooth finish on brick) Wall 105.05 0.02 2.101 Glass (Large pane) Fixed-Panel 52.91 0.02 1.0582 Openings Glass (Large Pane) Pivot Door 3.52 0.02 0.0704 Timber (Plywood) Pivot Door 4.4 0.1 0.44 Steel (Painted) Folding Door 2.2 0.54 1.188 Floor Concrete Screed Floor 122.29 0.02 2.4458 Fiber Board Mezzanine Floor 38.77 0.08 3.1016 Furniture Timber Table, Chair 5.87 0.18 1.0566 Timber Cupboard 5.8 0.05 0.29 Ceramic Countertop 6.54 0.02 0.1308 Concrete screed Counter 44.43 0.02 0.8886 Fabric Sofa 7.96 0.82 6.5272 MDF Sofa 13.3 0.1 1.33 People (Non- Peak Hour) 25 0.45 11.25 Total Absorption [A] 47.0248 The reverberation time for the cafe at 2000Hz during non-peak hours is at 2.38 seconds. This falls within the comfortable range of the public space which is between 1.5 – 2.5 seconds.
  • 95. 95 Reverberation Time at 4000Hz / Non-Peak Hour Table 6.4.4.3 : Reverberation Time at 4000Hz RT60 = (0.16 X V) / A = (0.16 X 700.53) / 46.1093 = 2.43s Component Material Function Area(m2 ) [A]/ Quantity Absorption Coefficient [S] Sound Absorption [SA] Ceiling Plaster (Gypsum Board, Smooth finish on lath) Ceiling 122.29 0.03 3.6687 Steel (Painted) Mezzanine Truss 14.84 0.57 8.4588 Wall Brick (Unglazed) Wall 38.3 0.07 2.681 Plaster (White, Smooth finish on brick) Wall 16.32 0.02 0.3264 Plaster (Black, Smooth finish on brick) Wall 105.05 0.02 2.101 Glass (Large pane) Fixed-Panel 52.91 0.02 1.0582 Openings Glass (Large Pane) Pivot Door 3.52 0.02 0.0704 Timber (Plywood) Pivot Door 4.4 0.07 0.308 Steel (Painted) Folding Door 2.2 0.57 1.254 Floor Concrete Screed Floor 122.29 0.02 2.4458 Fiber Board Mezzanine Floor 38.77 0.08 3.1016 Furniture Timber Table, Chair 5.87 0.2 1.174 Timber Cupboard 5.8 0.05 0.29 Ceramic Countertop 6.54 0.02 0.1308 Concrete screed Counter 44.43 0.02 0.8886 Fabric Sofa 7.96 0.7 5.572 MDF Sofa 13.3 0.1 1.33 People (Non- Peak Hour) 25 0.45 11.25 Total Absorption [A] 46.1093 The reverberation time for the cafe at 4000Hz during non-peak hours is 2.43 seconds. This is considered acceptable for a space that requires a balance of speech and music.
  • 96. 96 Reverberation Time at 500Hz / Peak Hour Table 6.4.4.4 : Reverberation Time at 500Hz RT60 = (0.16 X V) / A = (0.16 X 700.53) / 66.3507 = 1.69s Component Material Function Area(m2 ) [A]/ Quantity Absorption Coefficient [S] Sound Absorption [SA] Ceiling Plaster (Gypsum Board, Smooth finish on lath) Ceiling 122.29 0.06 7.3374 Steel (Painted) Mezzanine Truss 14.84 0.44 6.5296 Wall Brick (Unglazed) Wall 38.3 0.03 1.149 Plaster (White, Smooth finish on brick) Wall 16.32 0.02 0.3264 Plaster (Black, Smooth finish on brick) Wall 105.05 0.02 2.101 Glass (Large pane) Fixed-Panel 52.91 0.04 2.1164 Openings Glass (Large Pane) Pivot Door 3.52 0.04 0.1408 Timber (Plywood) Pivot Door 4.4 0.15 0.66 Steel (Painted) Folding Door 2.2 0.44 0.968 Floor Concrete Screed Floor 122.29 0.015 1.83435 FiberBoard Mezzanine Floor 38.77 0.06 2.3262 Furniture Timber Table, Chair 5.87 0.15 0.8805 Timber Cupboard 5.8 0.05 0.29 Ceramic Countertop 6.54 0.01 0.0654 Concrete screed Counter 44.43 0.015 0.66645 Fabric Sofa 7.96 0.77 6.1292 MDF Sofa 13.3 0.1 1.33 People (Peak Hour) 75 0.42 31.5 Total Absorption [A] 66.3507 The reverberation time for the cafe at 500Hz during peak hours is 1.69 seconds. This is well within the boundary of 1.5 – 2.5 seconds and shows that the cafe has adequate acoustic absorption properties.
  • 97. 97 Reverberation Time at 2000Hz / Peak Hour Table 6.4.4.5 : Reverberation Time at 2000Hz RT60 = (0.16 X V) / A = (0.16 X 700.53) / 69.5248 = 1.61s Component Material Function Area(m2 ) [A]/ Quantity Absorption Coefficient [S] Sound Absorption [SA] Ceiling Plaster (Gypsum Board, Smooth finish on lath) Ceiling 122.29 0.04 4.8916 Steel (Painted) Mezzanine Truss 14.84 0.54 8.0136 Wall Brick (Unglazed) Wall 38.3 0.05 1.915 Plaster (White, Smooth finish on brick) Wall 16.32 0.02 0.3264 Plaster (Black, Smooth finish on brick) Wall 105.05 0.02 2.101 Glass (Large pane) Fixed-Panel 52.91 0.02 1.0582 Openings Glass (Large Pane) Pivot Door 3.52 0.02 0.0704 Timber (Plywood) Pivot Door 4.4 0.1 0.44 Steel (Painted) Folding Door 2.2 0.54 1.188 Floor Concrete Screed Floor 122.29 0.02 2.4458 Fiber Board Mezzanine Floor 38.77 0.08 3.1016 Furniture Timber Table, Chair 5.87 0.18 1.0566 Timber Cupboard 5.8 0.05 0.29 Ceramic Countertop 6.54 0.02 0.1308 Concrete screed Counter 44.43 0.02 0.8886 Fabric Sofa 7.96 0.82 6.5272 MDF Sofa 13.3 0.1 1.33 People (Peak Hour) 75 0.45 33.75 Total Absorption [A] 69.5248 At 2000Hz. the reverberation time for the cafe during peak hours is 1.61 seconds which satisfies the requirement of such space to be within 1.5 – 2.5 seconds.
  • 98. 98 Reverberation Time at 4000Hz / Peak Hour Table 6.4.4.6 : Reverberation Time at 4000Hz RT60 = (0.16 X V) / A = (0.16 X 700.53) / 68.6093 = 1.63s Component Material Function Area(m2 ) [A]/ Quantity Absorption Coefficient [S] Sound Absorption [SA] Ceiling Plaster (Gypsum Board, Smooth finish on lath) Ceiling 122.29 0.03 3.6687 Steel (Painted) Mezzanine Truss 14.84 0.57 8.4588 Wall Brick (Unglazed) Wall 38.3 0.07 2.681 Plaster (White, Smooth finish on brick) Wall 16.32 0.02 0.3264 Plaster (Black, Smooth finish on brick) Wall 105.05 0.02 2.101 Glass (Large pane) Fixed-Panel 52.91 0.02 1.0582 Openings Glass (Large Pane) Pivot Door 3.52 0.02 0.0704 Timber (Plywood) Pivot Door 4.4 0.07 0.308 Steel (Painted) Folding Door 2.2 0.57 1.254 Floor Concrete Screed Floor 122.29 0.02 2.4458 Fiber Board Mezzanine Floor 38.77 0.08 3.1016 Furniture Timber Table, Chair 5.87 0.2 1.174 Timber Cupboard 5.8 0.05 0.29 Ceramic Countertop 6.54 0.02 0.1308 Concrete screed Counter 44.43 0.02 0.8886 Fabric Sofa 7.96 0.7 5.572 MDF Sofa 13.3 0.1 1.33 People (Peak Hour) 75 0.45 33.75 Total Absorption [A] 68.6093 The reverberation time for the cafe at 4000Hz during peak hours is 1.63 seconds. This falls within the required range 1.5 – 2.5 seconds. This range is the general range for spaces that requires a balance mix of speech and music.
  • 99. 99 Reverberation Time Analysis and Conclusion From the gathered data, the reverberation timing for 500Hz, 2000Hz and 4000Hz could be acquired and there is a noticeable pattern that emerged from both peak and non-peak hours. The reverberation time for non-peak hours are gathered at the higher end of the desired range of 1.5 to 2.5 seconds while the reverberation time for peak hours are reduced to the lower end of the range. The reverberation time is indirectly proportional to the amount of occupants inside the space as people contributes significantly towards acoustic absorption of the space and help enhance it. The reasons why the cafe has a high reverberation time is due to the double volume of the space which has a height of 5.7 meters. This high reverberation time is further bolstered by the lack of acoustic absorbing materials such as concrete, which, when sound reaches the material, get reflected more than it gets absorbed, and consequently creating a higher reverberation time. Even though the reverberation time is quite high for a comfort human range of 0.8 to 1.3 seconds, it is quite acceptable for a cafe that requires the balance blend between soft music and relaxing conversation. Hence, it is safe to say that the cafe has a good acoustic reverberation properties.
  • 100. 100 6.4.5 Sound Reduction Index Calculation Sound Reduction Index The first floor sitting area is identified as the main space to analyze the acoustic transmission from and into the area. Not only that this space incorporates the main sitting area (ZONE 1) and the coffee counter (ZONE 2), but as well as the immediate outdoor sitting area. The outdoor sitting area (ZONE 3) is established as the secondary area to record sound transmission into that particular space, in order to understand whether acoustic measures such as the selection of materials are sufficient to buffer sound between these spaces and is essential to identify the acoustic ratings of these two spaces. For main sitting area and coffee counter area: Figure 6.4.5.1 : Zone 1 Plan
  • 101. 101 Main Area + Cafe Bar Materials Surface Area (m2 ) Transmission coefficient of material Sn X Tcn Concrete Wall 131.53 6.31 X 10-5 8.3 X 10-3 Brick Wall 40.54 5.01 X 10-6 2.03 X 10-4 Glass Wall 61.51 2.51 X 10-4 1.54 X 10-2 Glass Door 3.52 2.51 X 10-4 8.84 X 10-4 Total Surface Area 246.1 Table 6.4.5.1 : SRI Tabulation TAV = (8.3 X 10-3 + 2.03 X 10-4 + 1.54 X 10-2 + 8.84 X 10-4 ) / Total Surface Area = 2.48 X 10-2 SRI Overall = 10Log10 (1 / 2.48 X 10-2 ) SRI Overall = 16.06 dB
  • 102. 102 For outdoor sitting area: Figure 6.4.5.2 : Zone 2 Plan Private Gathering Space Materials Surface Area (m2 ) Transmission coefficient of material Sn X Tcn Concrete Wall 30.78 6.31 X 10-5 1.94 X 10-3 Brick Wall 14.7 5.01 X 10-6 7.36 X 10-5 Glass Wall 36.82 2.51 X 10-4 9.24 X 10-3 Glass Door 2.2 2.51 X 10-4 5.52 X 10-4 Total Surface Area 84.5 Table 6.4.5.2 : SRI Tabulation TAV = (1.94 X 10-3 + 7.36 X 10-5 + 9.24 X 10-3 + 5.52 X 10-4 ) / Total Surface Area = 1.4 X 10-4 SRI Overall = 10Log10 (1 / 1.4 X 10-4 ) SRI Overall = 38.53 dB
  • 103. 103 6.5 Analysis and Evaluation Table: Sound Environments with their corresponding Sound Pressure Levels(Source: http://trace.wisc.edu/docs/2004-About-dB/) With reference to the table of general sound environments, the noise level readings of the main and private sitting areas are averagely between 60-79dB, which means that the noise levels in these areas are from normal to four times as loud as a conversation noise level. It is considered as a typical acoustic trait, being a café with customers converse, as well as music being played from the speakers. The coffee counter has a relatively higher reading of 70-89dB, which is four times louder than the sound level of a normal conversation. The high readings were contributed by the noise level from the coffee machines and grinders that are being utilized from time to time. The noise level of the coffee counter is also contributed by the use of speakers for background music in the café. Artisan Café has a typical overall noise levels that are common in other cafes and restaurants. However, during peak hours it may be quite loud, as the more customers there are in the café, the higher volume of music being played on the speakers will be used to mask the conversation noises.
  • 104. 104 7.0 REFERENCES 1. STC Chart (n.d.).STC Ratings for Brick and Concrete Block. Retrieved from http://www.sae.edu/reference material/pages/STC%20Chart.html 2. Paroc Group (2014). Sound Insulation. Retrieved from http://www.paroc.com/knowhow/sound/sound-insulation 3. ThomasNet (2014).Sound Absorption Coefficients. Retrieved from http://www.sae.edu/reference material/pages/Coeffieicnet%20Chart.html 4. Hongkong Institute of Architects.(2008). Wave Motion, Noise Control in Architecture. 5. Harris, Cyril M. Noise Control in Buildings: A Practical Guide for Architects and Engineers. NewYork: McGraw-Hill, 1993. 6. Neufert, Ernst and Peter.Neufert Architects’ Data. Oxford: Wilet-Blackwell, 2012 7. AZO Network (2014). Sound Transmission and Insulation in Brick and Masonry Walls.Retrieve from http://www.azom.com/article.aspx?ArticleID=1326 8. Deru, M., Torcellini, P., Sheffer, M., & Lau, A. (2005).Analysis of the Design and Energy Performance of the Pennsylvania Department of Environmental protection Cambria Office Building. Doi:10.2172/15016075 9. INTERIOR LIGHTING DESIGN A STUDENT’S GUIDE. (n.d.) Retrieved from http://www.slideshare.net/nosuhaila/interior-lighting-design-a-students-guide
  • 105. 105 10. Malaysia. (2007). Code of practice on energy efficiency and use of renewable energy for non- residential buildings (first revision).Putrajaya: Department of Standard Malaysia. 11. Subtle variations: the uses of artificial and natural light in the menil collection, Houston, texas, (n.d) Retrieved from http://www.arch.ced.berkeley.edu/vitalsigns/bld/toolkit_studies/menil%20collection%20-- %20Subtle%20Variations.pdf 12. Technical – Photometric Data Guid. (n.d) Retrieved from http://lightsbylinea.com/index.php?route=information%2Finformation&information_id=10 13. Robert B. (n.d) Noise Control for Buildings. Guidelines for Acoustical Problem Solving Retrieve from http://www.certainteed.com/resources/NoiseControl%20Brochure%203 14. Long, M. (2006). Architectural acoustics. Amsterdam: Elsevier/Academic Press. 15. Barton, C.K,.& Construction Engineering Research Laboratory. (1987). Development of LITE graphic module for lighting analysis in the Computer-Aided Engineering and Architectural Design System(CAEADS). Champaign, IL: US Army Corps of Engineers, Construction Engineering Research Laboratory. 16. Calculux Indoor – Philips Lighting Singapore. (n.d) Retrieved from http://www.lighting.philips.com/pwc_li/cn_zh/connect/tools_literature/Assets/downloads/ manual_indoor.pdfCIBSE. (2002). Code for lighting. Burlington: Elsevier. 17 Coefficient Chart. (n.d). Retrieved from http://www.sae.edu/reference_material/pages/Coefficient%20Chart.htm
  • 106. 106 8.0 APPENDIX LIST OF FIGURES Figure 2.1.1 : Image of Solar Decathlon House Figure 2.1.1: Floor Plan of Solar Decathlon House Diagram 2.1.2 : Analysis Diagram Figure 2.2.1 : Yildiz Technical University Auditorium Figure 2.2.2: Section of the YTU auditorium (after renovation) Figure 2.2.3: Plan of YTU auditorium (after renovation) Figure 3.1.1 : digital lux meter Diagram3.1.1 : Standard height used to record Lux readings Figure 3.2.1 : Digital Sound Level Meter Figure4.1.2: Site Context of the Cafe Figure 4.7.1 : Ground Floor Zoning Figure 4.7.2 : Mezzanine Floor Zoning Diagram 5.2.1 Daylight Lux Contour Diagram Diagram 5.2.2 Artificial Lux Contour Diagram Figure 6.1.2: Placement of Air Circulators Figure 6.1.3: Human activity point Figure 6.1.4: Position of Speakers
  • 107. 107 LIST OF TABLES Table 2.1.1 : Materiality Reflectance Table Table 2.2.1:Surface materials in auditorium, their surface area and absorption coefficient (based on Harris, 1994:Cavanaugh & Wilco, 1999) Table 2.2.2 RTs Calculation Table 2.2.3 : Measured and acceptable BSLs (air conditioning) Table 2.2.4: Measured, calculated and optimum RTs of YTU auditorium for speech activities Table 4.1.1 Artifial Lighting Sources Table 4.1.2 Acoustic Sources Table 5.1.1 Daytime Lux Readings Table 5.1.2 Nightime Lux Readings Table 6.2.1 Peak and Non - Peak Hours Readings
  • 108. 108