2. • 2 types
• Temporary and
• Permanent Structures
• Temporary Structures
• Temporary structures should be recommended only where inexpensive
labor and materials are available.
• Increasing mechanization and higher labor costs have resulted in a
decline in the practicality of temporary channel stabilization structures.
• Practices that make use of temporary materials such as logs and root
wads can be effective if combined with channel modifications that will
result in a stable stream.
• Without such modifications, the problems are likely to recur,
progressively degrading the land.
3. • Permanent Structures
• Permanent structures of hard materials may be required
to dissipate the energy of the water,
• for example, where a vegetated waterway discharges
into a drainage ditch, at the head of a large gully, or in a
channel reach where the grade is too steep to be stable.
• Where flow velocities must exceed the maximum values
for nonerosive conditions , an erosion-resistant lining
may be required.
4. Figure 9.1 shows the profile of a gully that has been reclaimed by
methods involving the use of several types of permanent structures.
Figure 9.1–Profile of a gully stabilized by three types of permanent structures.
5. The design of control structures must address two primary
requirements:
(1) adequate capacity to pass the design discharge, and
(2) dissipation of the energy of the water within the structure in a
manner that protects both the structure and the down- stream channel
from damage or erosion.
The main causes of failure of permanent control structures are
insufficient hydraulic capacity and insufficient energy dissipation
capacity.
All permanent structures require maintenance, though it may be
infrequent.
Where maintenance is neglected, small problems can grow and
eventually lead to total failure.
6. The basic components of a hydraulic structure are
the inlet,
the conduit, and
the outlet.
Structures are classified and named in accordance with
the form of these three components.
7.
8. In addition to these hydraulic features, the structure must include suitable
wing walls, side walls, head wall extensions, and toe walls to prevent seepage
under or around the structure and to prevent damage from local erosion.
9. It is important that a firm foundation be secured for permanent
structures.
Wet foundations should be avoided or provided with adequate
artificial drainage.
Topsoil and organic material should be removed from the site to
allow a good bond between the structure and the foundation
material.
Many energy dissipation structures make use of a hydraulic
jump, which is a transition from a relatively shallow and rapid
flow to a relatively deep and slow flow. Flow in the transition
zone is highly turbulent and dissipates some of the energy of the
water.
10. A typical drop spillway is shown in Figure 9.3. Drop spillways
may have a straight, arched, or box-type inlet. The energy
dissipater may be a straight apron or some type of stilling basin.
11. Drop spillways are installed in channels to establish permanent control
elevations below which an eroding stream cannot lower the channel floor.
The structures control the stream grade from the spillway crest through
the entire ponded reach upstream.
Drop structures placed at intervals along the channel can stabilize it by
changing its profile from a continuous steep gradient to a series of more
mildly sloping reaches.
Where relatively large volumes of water must flow through a narrow
structure at low head, the box-type inlet is preferred.
The curved inlet serves a similar purpose and also gives the advantage of
arch strength where masonry construction is used.
Drop spillways are usually limited to drops of 3 m; flumes or drop-inlet pipe
spillways are used for greater drops.
MM HASAN,LECTURER,AIE,HSTU
12. Capacity. The free flow (i.e., with no submergence) capacity for drop
spillways is given by the weir formula
q = CLh3/2
where q = discharge (L3T-1),
C = weir coefficient (L1/2T-1),
L = weir length (L),
h = depth of flow over crest (L)
The length L is the sum of the lengths of the three inflow sides of a box inlet,
the circumference of an arch inlet, or the crest length of a straight inlet.
Using C = 1.8 will also give satisfactory results for the straight inlet or the
control section of a flood spillway.
The inlet should have a freeboard of 0.15 m above h, the height of the water
surface.
MM HASAN,LECTURER,AIE,HSTU
13. Apron Protection
The kinetic energy gained by the water as it falls from the
crest must be dissipated and/or converted to potential
energy before the flow exits the structure.
For straight-inlet drop structures the dissipation and
conversion of energy are accomplished in either a
straight apron or a Morris and Johnson (1942) stilling
basin.
Dimensions for the Morris and Johnson stilling basin are
given in Figure 9.5.
MM HASAN,LECTURER,AIE,HSTU
17. MM HASAN,LECTURER,AIE,HSTU
Chutes are designed to carry flow down steep
slopes through a concrete-lined channel rather
than by dropping the water in a free overfall.
18. MM HASAN,LECTURER,AIE,HSTU
Chutes may be used for the control of elevation changes up to 6
m.
They usually require less concrete than drop-inlet structures of
the same capacity and elevation change.
However, there is considerable danger of undermining of the
structure by burrowing animals and, in poorly drained locations,
seepage may threaten foundations.
Where there is no opportunity to provide temporary storage
above the structure, the inherent high capacity of the chute
makes it preferable to the drop-inlet pipe spillway.
The capacity of a chute is not decreased by sedimentation at the
outlet.
19. MM HASAN,LECTURER,AIE,HSTU
Capacity
Chute capacity normally is controlled by the inlet section.
Inlets may be similar to those for straight-inlet or box-inlet
drop spillways, for which the capacity formulas already
discussed will apply.
Outlet Protection
The cantilever-type outlet should be used where the
channel grade below the structure is unstable.
In other situations, either the straight-apron or St. Anthony
Falls (SAF) outlet is suitable. The straight apron is applicable
to small structures. Figure 9.8 shows dimensions of the SAF
type of stilling basin.
21. MM HASAN,LECTURER,AIE,HSTU
Function and Limitations
The formless flume structure has the advantage of low-cost
construction.
It may replace drop spillways where the fall does not exceed 2 m and
the width of notch required does not exceed 7 m.
The flume is constructed by shaping the soil to conform to the shape of
the flume and applying a 0.13-m layer of concrete reinforced with wire
mesh.
Since no forms are needed, the construction is simple and inexpensive.
The formless flume should not be used where water is impounded
upstream (due to the danger of undermining the structure by seepage)
or where freezing occurs at great depth.
23. MM HASAN,LECTURER,AIE,HSTU
Figure 9.9 shows the design features and dimensions
of the formless flume.
The capacity is given by Equation 9.1 using C = 2.2 (SI).
This weir coefficient accounts for the increased cross-
sectional area because the sides of the weir slope
outward rather than vertically and the entrance is
rounded.
The depth of the notch, D, is h plus a free- board of
0.15 m.
24. MM HASAN,LECTURER,AIE,HSTU
Pipe spillways may take the form of a simple conduit under a fill
(Figure 9.10a) or they may have a riser on the inlet end and
some type of structure for outlet protection (Figure 9.10b).
The pipe in Figure 9.10c, called an inverted siphon, is often used
where water in an irrigation canal must be conveyed under a
natural or artificial drainage channel.
Inverted siphons must withstand hydraulic pressures much
higher than those encountered in other pipe spillways and
therefore require special attention to structural design.
26. MM HASAN,LECTURER,AIE,HSTU
The pipe spillway used as a culvert has the simple function of
providing for passage of water under an embankment.
When combined with a riser or drop inlet, the pipe spillway serves to
lower water through a considerable change in elevation and to
dissipate the energy of the falling water.
Drop-inlet pipe spillways are thus frequently used as gully control
structures.
This application is usually made where water may pond behind the
inlet to provide temporary storage.
27. MM HASAN,LECTURER,AIE,HSTU
Culverts.
Culvert capacity may be controlled by either the inlet section or
the conduit.
The headwater elevation may be above or below the top of the
inlet section.
Several possible flow conditions are represented in Figure 9.11.
Solution of a culvert problem requires determination of the type
of flow that will occur under given headwater and tailwater
conditions.
Consider a culvert as shown in Figures 9.11a and 9.11b.
29. MM HASAN,LECTURER,AIE,HSTU
Pipe flow (i.e., where the conduit controls capacity) will usually
occur where the slope of the culvert is less than the neutral
slope and entrance capacity is not limiting.
The neutral slope sn is
where
Hf = friction loss in conduit of length L (L),
L = length of conduit (L),
Kc = conduit friction loss coefficient (Tables C.2 and C.3) (L-1),
v = velocity of flow (LT-1),
g = gravitational acceleration (LT-2).
30. MM HASAN,LECTURER,AIE,HSTU
The capacity of the culvert under conditions of full pipe flow is
given by
where q = discharge capacity (L3T-1),
A = conduit cross-sectional area (L2),
H = head causing flow (L),
Ke = entrance loss coefficient,
Kb = bend loss coefficient,
Kc = conduit loss coefficient.
For full pipe flow, H is taken as the difference between the headwater elevation and the point
0.6 times the culvert diameter above the downstream invert (Figure 9.11a). Values of Kb, Kc, and
Ke are given in Appendix C.
31. MM HASAN,LECTURER,AIE,HSTU
If the inlet is submerged, the slope of the conduit is greater than
neutral slope, and the outlet is not submerged, then the flow
will be controlled by the inlet section on short-length culverts,
and orifice flow will control. Discharge capacity is then given by
where q = discharge capacity (L3T-1),
A = conduit cross-sectional area (L2),
H = head causing flow (L),
C = orifice discharge coefficient.
32. MM HASAN,LECTURER,AIE,HSTU
The discharge characteristics of a drop-inlet pipe spillway (Figure 9.13)
are determined by the component of the system that controls the
flow rate.
At low heads, the crest of the riser controls the flow (as a weir) and
discharge is proportional to h3/2.
Equation 9.1 should be used to calculate the discharge for these
conditions.
As the head increases, the capacity of the weir will eventually equal
the capacity of the conduit (pipe flow) or the conduit inlet section
(orifice flow).
The flow will then be proportional to the square root of either the
total head loss through the structure or the head on the conduit inlet,
depending on whether pipe flow or orifice flow controls the discharge.
34. MM HASAN,LECTURER,AIE,HSTU
For mechanical spillways on ponds and similar small structures the hood inlet
provides a relatively simple and inexpensive alternative to the drop inlet.
The hood inlet, when provided with a suitable antivortex device, will cause
the pipe to prime and flow full for spillway slopes up to 30%.
Hood inlets shown in Figures 9.14a and 9.14b were developed by Blaisdell
and Donnelley (1958).
Beasley et al. (1960) reported that a hood inlet with an endplate as shown in
Figure 9.14c gave satisfactory performance although the entrance loss was
somewhat higher than with the other two.
The discharge characteristics of these three inlets are shown in Figure 9.14d
for a pipe of length 110D. For H/D less than 1, weir flow occurs.
Up to H/D of about 1.4, the flow is erratic.
Above H/D of 1.4 the vortex is eliminated and pipe flow controls.
36. MM HASAN,LECTURER,AIE,HSTU
For small culverts or drop-inlet pipe spillways,
the cantilever- type outlet is usually satisfactory.
The straight apron outlet may be used in some
instances. Large drop-inlet pipe spillways may
be provided with the SAF stilling basin discussed
in Section 9.7.
37. MM HASAN,LECTURER,AIE,HSTU
The neutral slope is the slope of energy grade
line when the pipe just flows full, i.e.,
when the momentum due to the inertial force
and the momentum loss due to friction are
equal.