SlideShare a Scribd company logo
1 of 5
Download to read offline
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072
© 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2651
Design of Metal Deck Sheet and Composite I-Section as secondary
member
Lokesh Rathore1, Jaswant Singh2
1Post Graduate student in structural engineering ,department of civil engineering , CBS Group of Institutions,
Fatehpuri, Jhajjar , Haryana, India
2Assistant Professor, department of civil engineering , CBS Group of Institutions,Fatehpuri, Jhajjar , Haryana, India
---------------------------------------------------------------------***---------------------------------------------------------------------
Abstract - In recent times steel structures are being
adopted for construction of structures conforming to their
advantages over conventional RCC structures. India is the
world's second-largest cement producer, so before the year
2000 most of the constructions were done in RCC and there
were other numerous reasons for this some of them being, in
RCC construction lesser skilled labours were required, the
deadline of the project did not matter ,there was a lack of
higher grade steel and large steel sections were not readily
available but after the year 2000 steelstructuresweregaining
popularity and their execution was started ,the chief reason
for this was the shift in market from cost oriented to time
oriented construction. During this time there was
unavailability of higher section sizes in steel tubes so built-up
composite structures were preferred. Theproductionofhigher
cross section tube sizes was started in 2019 by some vendors
like TATA ,APL Apollo, this has revolutionizedtheconstruction
market and a some of new constructions are being done in
steel structures now.
Key Words: Steel structure, Earthquake, Seismic, Metal
deck sheet, I-Section, Composite tube.
1. INTRODUCTION
A steel structure may be defined as a metal construction
made mostly of structural steel components and sections
that are joined to one another in various ways like welding,
bolting, or riveting to carry loads from the structure (also
known as dead loads) and from people inside the structure
(also known as Live Loads) & provides rigidity. Due to steels
high strength to counter tensile and compressive stresses,
these structures are reliable and require lessrawmaterial in
comparison to some other types of structural materialssuch
as concrete.
To meet the requirements of a project, structural steel is
manufactured with a certain shape and chemical
composition. In present day construction practices,
structures made of steel areemployedalmostfor everyother
type of structure which includes high-rise buildings, towers,
bridges, infrastructure, support systems for equipment and
machinery, heavy industrial building, heavy industrial plant,
etc.
Adhering to every structural specification, the dimensions
for steel members formed by hot and cold rolled procedures
are connected by welding or bolting flat and bent plates
together. Frequently adoptedshapesaretheIshapedbeams,
Hollow sections, angle, channel, and plates.
1.1 ADVANTAGES OF STEEL STRUCTURES
Structures made from steel sections are quickly built at the
project site because majority of building components could
be prefabricated at the workshop or Steel manufacturing
facility. The Expansion of any steel Structure can
comparatively be very easy and fast. As steel can be molded
into different shapes as a result repair & rehabilitation
and/or retrofitting is conveniently possible. As the steel
building components are prepared in the workshop, the
erection of the structure at site is fast in comparison to other
building materials.
Because of their flexibility, they are excellent at resisting
dynamic (changing) forces like wind or seismic forces. In
earthquake zones, the fact that steel may bend without
cracking serves as a warning. Thereisalargeselectionofpre-
made structural sections, including I, C, and angle sections.
They can be fashioned into any shape and covered with any
kind of shape. Bolting, welding, and riveting are just a few of
the connecting techniques that are accessible. we can also
recycle steel. About one-third of the energy required to
produce new steel from scrap steel is used in this process.
1.2 DISADVANTAGES OF STEEL STRUCTURES
Before forming a structural system, analytical approaches
and assumptions must be fairly clear and final. The time
consumed to design a connection is longer than that of an
RCC structure connection. The cost of structural steel
(especially India) is higher than RCC. Skilled workforce is
required. Steel has a property of becoming soft and melting
when exposed to very high temperatures.
Additional fire protection, such as spray on fireproofing,
structural steel buildings can withstand high temperatures,
which in turn enhances security. They tend to corrode in
damp or marine environments. Hence, consistent care is
needed.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072
© 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2652
2. PROJECT STRUCTURAL SCHEME
All structural design and analysis must adhere to the latest
Provisions of the Indian Standard codes for Steel and RCC
construction primarily IS 800:2007 and IS 456:2000.
Special quality weld joints allowing 100% tension strength
shall be required. Non-destructive testing techniquesshould
be used for weld quality inspection and control. For slip-
critical joints a slip factor of 0.5 shall be used in accordance
with IS 4000 with specified surface treatment and
preparation.
2.1. LOADS ON STRUCTURE
Dead load
Self-weight
The unit weight of materials shall conform to IS 875 – Part 1.
The self-weight ofstructureisautomaticallycalculatedbythe
analysis software depending upon the cross-sectional area
and density of each member.
Density of R.C.C members = 25.0 kN/m3
Density of P.C.C members = 24.0 kN/m3
Density of structural steel = 78.5 kN/m3
Density of brick masonry walls (230/115 mm thick) = 20.0
kN/m3
Dry density of soil = 18.0 kN/m3
Density of saturated soil = 20.0 kN/m3
Density of water = 10.0 kN/m3
Density of floor finish = 24.0 kN/m3
Density of plaster = 24 kN/m3
Dead load on all floors
Screed and Finishes (50mm)on typical floors = 0.05 m×25=
1.2 kN/m2
Service Loads = 1 kN/m2
Partition Walls = 1 kN/m2
Dead load on Terrace
Screed and Finishes (150mm) = 0.150 m × 25 = 3 kN/m2
Service Loads = 1 kN/m2
Parapet Walls (1.5 meters) = 0.45 kN/m
Live load
Live load on all floors = 3 kN/m2
Live load on Terrace = 1.5 kN/m2
Basic Wind speed = 50m/s
Seismic zone = IV
Soil type = II
Response reduction factor = 5
3. DESIGN OF METAL DECK SLAB
The sheeting is designed for Self-weight of the Slab and
Sheeting, and Erection loads
Clear thickness of Concrete slab = 80.00 mm
D overall thick =155 mm
Avg thk. of Concrete slab within deck sheeting = 37.50 mm
average thick =118 mm
Service load =1 kN/m2
Partition load =1 kN/m2
Live load =3 kN/m2
Service+ partition + live load =5.000 kN/m2
Flooring thickness =50.00 mm
Flooring density = 24.00 kN/m3
Erection Load = 5.00 kN/m2
Sheeting thickness = 1.00 mm
Self-Weight of the sheeting = 11.96 kg/m2
Dead weight of deck slab =(0.08+0.0375) x 252+ 0.050 x
24+0.1196
= 4.3 kN/m2
Z of sheeting = 36.26 cm3
Spacing of beam (Maximum) = 2.00 m
Load to be carried by sheeting = 9.3 kN/m2
(80+35)*.025+5(Erection)+50x0.024+.1196(self weight)
Depth of the Decking Profile = 75.00 mm
Flange width of supporting beam assumed = 140.00 mm
Effective Span for the Decking Sheet Design = 1.94 m
230
75
Fig -1: Deck Sheet Profile
B.M FACTOR FOR SHEETING = 8.00
Allowable bending stress in Sheeting = 165 N/mm2
(0.66 * 250MPa considered)
Bending Moment (9.3 x 2 x 2 x 1000/8) = 4.65 kN-m
Bending Stress (4650000/(36.26x1000))= 129.81 N/mm2
<165 O.k
Check for Deflection
Total Load = 9.3 kN/m/m
SPAN = 2.00 m
SPAN (Effective) = 1.94 m
IXX = 1473000 mm4
Defl. Coeff. = 5/384
Limiting Deflection Ratio for Deck Sheet = 200
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072
© 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2653
Allowable Deflection = 9.68 mm
Vertical Deflection = 5.76 mm
(5x9.3x(1.935x1000)^4)/(384x200000x 1473000)
<<9.68 O.K
4. DESIGN OF SECONDARY BEAM
SPAN OF THE BEAM = 7.50 m
Provide Beam as = ISMB350
Width of the falange = 140.00 mm
Area of the section = 6671.00 mm2
Ixx of the section =136303000mm4
Zxx of the section = 778874 mm3
Rmin of the section = 28.40 mm
Depth of the section = 350.00 mm
Flange thickness = 14 mm
Web thickness = 8 mm
Flange width = 140 mm
Design of beam by using Composite action
Assumptions
1) Dead load of Concrete slab & self-weight of beam and
construction load of 1.5 kn/sqm is taken by Steel beam only.
2) Only balance live load & flooring load is resisted by
composite construction after the concrete is hardened.
3) Area of the concrete with in profile depth is ignored for
effective width calculation of slab.
4) Design of shear connector as per IS:11384-1985 for
ultimate shear capacity of concrete.
Modulur Ratio = 280 / 3 s cbc,
= 280 / 3 x 8.5= 10.98
Depth of Deck Sheeting = 70.00 mm
Area of reinforcement perpendicular to Beam=2.50 cm2
(Ast provided in slab)
Effective Width of Slab Lesser of the following
1) Span /4 = 7.5x1000/4 = 1875.00 mm
2) 12xslab thk.+Flange width = 12x80+140
= 1100.00 mm
3) Spacing of beams = 2000.00 mm
So effective width
= 1100.00 mm
Transformed width = 1100/10.98
= 100.18 mm
C.G from bottom
=
(6671x350x0.5+100.2x80x[350+75+80x0.5])/(6671+100.2x
80)
= 333.27 mm
Ixx of combined section
136303000 + 6671x(333.3-175)^2 + 100.2x80^3/12 +
100.2x80x(350+75+80x0.5-333.3)^2
= 4.47E+08 mm4
Zxx at bottom = 446757145.4/333.3
= 1.34E+06 mm3
100.2
80
75 14
350
333.27
140
Fig -2: I section with deck slab in equivalent steel area
Stresses due to Dead weight + Construction live load
(only Steel beam action)
Udl on beam WITH construction load of 1.5 kn/sqm
= 0.80 t/m
{(80+35)x0.001x2.5+0.01196}x2+0.006671x7.85+0.15
Bending Moment 0.801x7.5x7.5/8 = 5.63t-m
Bending stress =56340516.8/778874
= 72.34 N/mm2
Deflection in beam = 12.11 mm
(5x0.80x10x(7500)^4)/(384x200000x136303000)
Stresses due to Imposed Load (composite action)
Additional Equivalent UDL due to Brick Wall = 0.00kN/m
Additional live load is 5-1.5 = 3.5kn/sqm
Udl on beam =(5-1.5 +0.05x24)x2 = 9.40 kN/m
Bending Moment = 9.4x7.5x7.5/8 = 66.09 kN-m
Bending Stress at bottom of steel =66.09375x
10000000/1340542.46 = 49.30 N/mm2
Total Bending Stresses = 72.34+49.30 = 121.64N/mm
< 165 O.K
Deflection due to balance Live load and finishing
5x9.4x(7500)^4/(384*200000x446757145.4) = 4.33 mm
Deflection Factor for Dead Load = 1000.00
Allowable deflection =7500/1000 =7.50 mm
(As Per IS 14687-1999 cl:7.5 (b) )
Total 'deflection' =4.3+12.11
= 16.44mm
< 23.1 O.K
Allowable deflection = 7500/325 = 23.08 mm
Zxx at top =446757145/(350+75+80-333.3)
=2.60E+06mm3
Bending compressive stress in concrete
66.1x1000000/(2601447.5x10.98) = 2.31 N/mm2
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072
© 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2654
< 8.33 O.K
Allowable bending comp. Stress in concrete
= 8.33 N/mm2
For M25 Grade = 25/3
(Cl. 13.0 IS:11384 -1985)
Fig -3: Composite I section
Check for Ultimate Limit state of Longitudinal Shear
Shear Stud Spacing:
Maximum Horizontal Shear (fcc) (Page No:7 IS:11384 -
1985)0.36*fckbXu = 0.36x25x1100x80/1000 = 792.00 kN
Shear capacity of each stud = 31.42 kN
Dia of stud = 20 mm
Height of the stud = 100 mm
No. of studs at cross section = 2
No. of studs =792/(2x31.4159265358979)
= 12.61
Spacing of studs Reqired : 3750 / 12.6 = 297.50 mm
Spacing of studs provided
= 250.00 mm
<600mm
< 4 x 80mm
Shear per Meter length (Q) =792 / 3.75 = 211.20 KN/M
Shear resistance of slab is minimum of the following ( Page
No:10 IS:11384 -1985)
0.232x2x80x SQRT(25)+0.1x2.5x500*2 = 435.60 kN/m
0.623x2x80x SQRT(25) = 498.40 kN/m
211.200<435.6O.K
Check for Ultimate Limit state of Vertical Separation
( CL. 10. IS:11384-1985)
Length of the shear connector
= 100 mm > 50mm O.K.
Projection of shear connector into the slab =100-0,100mm
> 25mm O.K.
Min. Diameter of Head = 1.5 xdia
= 30 mm
Design of Shear Studs
Dia of stud =20.00 mm
Yield stress of stud =245.00N/mm2
Maximum permissible shear stress =98.00 N/mm2
Area of stud =314.16 mm2
Shear capacity of stud =30.79 kN
Thickness of slab =250.00 mm
Floor thickness =50.00 mm
Total Load 1.0DL+0.5LL+EQL =11.19 kN/m2
Length of beam =7.50 m
Span of beam =2.00 m
Total Load =167.92 kN
Z = 0.24
I =1.50
Sa/g =2.50
R =5.00
Seismic coefficient,Ah =0.09
Horizontal force =22.67 kN
Spacing of stud =250.00 mm
No of studs provided =30.00
Say 30
Shear capacity of stud = 924 kN
> 22.67kN OK
5. CONCLUSIONS
Structures made from steel sections are quickly built at the
project site because majority of building components could
be prefabricated at the workshop or Steel manufacturing
facility.
The Expansion of any steel Structure can comparatively be
very easy and fast.
Steel structures have good scrap value with respect to RCC.
In tubular structures, members are capable to resist both
direction of lateral forces due to the good inertia propertyin
both directions.
Composite tubes constructions in columns is easy with
respect to I section encased in concrete column.
In the composite tube construction, no shuttering, de
shuttering, and bar bending is required.
Dynamic forces that change with time such as wind and/or
seismic waves are smoothly resisted by the flexile nature of
the steel.
Only one third energy is required to create new steel from
scrapped material than fresh steel alloy achieved from iron
ore.
REFERENCES
[1] Duggal, S.K Limit state design of steel structures. 3-
Ghobarah a. et al., “pushover analysis of steel frames”,
(1997)
[2] N Subramanian design of steel structures by Limit state
method.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072
© 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2655
[3] IS 1893(Part 1):2002, (2002), “Indian Standard criteria
for earthquake resistant design of structures”, (5th
revision).
[4] IS 800: 2007, “Indian Standard criteria for design of
steel structure.
[5] Hassan, O.F., Goel, S.C.(1991).”Modelling of bracing
members and seismic behavior of concentricallybraced
steel frames”.
[6] K.G.Vishwanath, “Seismic response of Steel braced
reinforced concrete frames”, International journal of
civil and structural engineering (2010)
[7] Khatib, I. and Mahin, S., Dynamic inelastic behavior of
chevron braced steel frames, Fifth Canadian Conference
on Earthquake Engineering, Balkema, Rotterdam,1987,
pages 211-220
[8] K.K.Sangle,K.M.Bajori,V.Mhalungkar,“Seismic AnalysisOf
High Rise Steel Frame With And WithOutBracing”,2012
9-Mateescu, G., & Molodovan, A. Resarch on seismic
behavior of steel structures.

More Related Content

Similar to Design of Metal Deck Sheet and Composite I-Section as secondary member

4. Introduction to DSS LSM.pdf
4. Introduction to DSS LSM.pdf4. Introduction to DSS LSM.pdf
4. Introduction to DSS LSM.pdfDEVNAIK7
 
Seismic Performance of Flat Slab Structures Under Static and Dynamic Loads
Seismic Performance of Flat Slab Structures Under Static and Dynamic LoadsSeismic Performance of Flat Slab Structures Under Static and Dynamic Loads
Seismic Performance of Flat Slab Structures Under Static and Dynamic LoadsIRJET Journal
 
Composite construction or Composite Structure/Frame
Composite construction or Composite Structure/FrameComposite construction or Composite Structure/Frame
Composite construction or Composite Structure/FrameAbdul Rahman
 
Module 1-Bolted Connection theory.pdf
Module 1-Bolted Connection theory.pdfModule 1-Bolted Connection theory.pdf
Module 1-Bolted Connection theory.pdfSandra Daya
 
IRJET - Analysis and Design of Steel Box Girder Bridge using Tekla Structures
IRJET - Analysis and Design of Steel Box Girder Bridge using Tekla StructuresIRJET - Analysis and Design of Steel Box Girder Bridge using Tekla Structures
IRJET - Analysis and Design of Steel Box Girder Bridge using Tekla StructuresIRJET Journal
 
Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...
Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...
Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...RSIS International
 
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...IRJET Journal
 
IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...
IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...
IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...IRJET Journal
 
COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...
COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...
COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...IRJET Journal
 
B tech individual report
B tech individual reportB tech individual report
B tech individual reportong93
 
Steel Structure Design (Study Report).pptx
Steel Structure Design (Study Report).pptxSteel Structure Design (Study Report).pptx
Steel Structure Design (Study Report).pptxMasudb1
 
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...IRJET Journal
 
EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...
EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...
EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...IRJET Journal
 
Profiled deck composite floors
Profiled deck composite floorsProfiled deck composite floors
Profiled deck composite floorsElamathy Murugan
 
A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...
A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...
A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...IRJET Journal
 

Similar to Design of Metal Deck Sheet and Composite I-Section as secondary member (20)

4. Introduction to DSS LSM.pdf
4. Introduction to DSS LSM.pdf4. Introduction to DSS LSM.pdf
4. Introduction to DSS LSM.pdf
 
Seismic Performance of Flat Slab Structures Under Static and Dynamic Loads
Seismic Performance of Flat Slab Structures Under Static and Dynamic LoadsSeismic Performance of Flat Slab Structures Under Static and Dynamic Loads
Seismic Performance of Flat Slab Structures Under Static and Dynamic Loads
 
Composite construction or Composite Structure/Frame
Composite construction or Composite Structure/FrameComposite construction or Composite Structure/Frame
Composite construction or Composite Structure/Frame
 
Module 1-Bolted Connection theory.pdf
Module 1-Bolted Connection theory.pdfModule 1-Bolted Connection theory.pdf
Module 1-Bolted Connection theory.pdf
 
IRJET - Analysis and Design of Steel Box Girder Bridge using Tekla Structures
IRJET - Analysis and Design of Steel Box Girder Bridge using Tekla StructuresIRJET - Analysis and Design of Steel Box Girder Bridge using Tekla Structures
IRJET - Analysis and Design of Steel Box Girder Bridge using Tekla Structures
 
Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...
Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...
Important Characteristics and Behavioral Impact of Materials to Be Used in Ta...
 
presentation
presentationpresentation
presentation
 
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
 
IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...
IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...
IRJET- Dynamic Analysis of Tall Tubular Steel Structures of Hexagon Configura...
 
Lecture 3 AP and RC MCEM.pptx
Lecture 3 AP and RC MCEM.pptxLecture 3 AP and RC MCEM.pptx
Lecture 3 AP and RC MCEM.pptx
 
COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...
COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...
COMPARATIVE STUDY ON ANALYSIS OF STEEL-CONCRETE COMPOSITE STRUCTURE WITH DIFF...
 
B tech individual report
B tech individual reportB tech individual report
B tech individual report
 
Beam design
Beam designBeam design
Beam design
 
Design of reinforced concrete beam
Design of reinforced concrete beamDesign of reinforced concrete beam
Design of reinforced concrete beam
 
Steel Structure Design (Study Report).pptx
Steel Structure Design (Study Report).pptxSteel Structure Design (Study Report).pptx
Steel Structure Design (Study Report).pptx
 
Presentation
PresentationPresentation
Presentation
 
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
Analysis of Multi-Storey Steel Structure with Different Infills and Steel Bra...
 
EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...
EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...
EFFECT OF STEEL BRACING ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE (RC) FR...
 
Profiled deck composite floors
Profiled deck composite floorsProfiled deck composite floors
Profiled deck composite floors
 
A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...
A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...
A Comparative Seismic Evaluation of GFRP Reinforced and Steel Reinforced Conc...
 

More from IRJET Journal

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...IRJET Journal
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTUREIRJET Journal
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...IRJET Journal
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsIRJET Journal
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...IRJET Journal
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...IRJET Journal
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...IRJET Journal
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...IRJET Journal
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASIRJET Journal
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...IRJET Journal
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProIRJET Journal
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...IRJET Journal
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemIRJET Journal
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesIRJET Journal
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web applicationIRJET Journal
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...IRJET Journal
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.IRJET Journal
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...IRJET Journal
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignIRJET Journal
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...IRJET Journal
 

More from IRJET Journal (20)

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web application
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
 

Recently uploaded

SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSCAESB
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfAsst.prof M.Gokilavani
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.eptoze12
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...srsj9000
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 

Recently uploaded (20)

SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentationGDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdfCCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
 
Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 

Design of Metal Deck Sheet and Composite I-Section as secondary member

  • 1. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2651 Design of Metal Deck Sheet and Composite I-Section as secondary member Lokesh Rathore1, Jaswant Singh2 1Post Graduate student in structural engineering ,department of civil engineering , CBS Group of Institutions, Fatehpuri, Jhajjar , Haryana, India 2Assistant Professor, department of civil engineering , CBS Group of Institutions,Fatehpuri, Jhajjar , Haryana, India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - In recent times steel structures are being adopted for construction of structures conforming to their advantages over conventional RCC structures. India is the world's second-largest cement producer, so before the year 2000 most of the constructions were done in RCC and there were other numerous reasons for this some of them being, in RCC construction lesser skilled labours were required, the deadline of the project did not matter ,there was a lack of higher grade steel and large steel sections were not readily available but after the year 2000 steelstructuresweregaining popularity and their execution was started ,the chief reason for this was the shift in market from cost oriented to time oriented construction. During this time there was unavailability of higher section sizes in steel tubes so built-up composite structures were preferred. Theproductionofhigher cross section tube sizes was started in 2019 by some vendors like TATA ,APL Apollo, this has revolutionizedtheconstruction market and a some of new constructions are being done in steel structures now. Key Words: Steel structure, Earthquake, Seismic, Metal deck sheet, I-Section, Composite tube. 1. INTRODUCTION A steel structure may be defined as a metal construction made mostly of structural steel components and sections that are joined to one another in various ways like welding, bolting, or riveting to carry loads from the structure (also known as dead loads) and from people inside the structure (also known as Live Loads) & provides rigidity. Due to steels high strength to counter tensile and compressive stresses, these structures are reliable and require lessrawmaterial in comparison to some other types of structural materialssuch as concrete. To meet the requirements of a project, structural steel is manufactured with a certain shape and chemical composition. In present day construction practices, structures made of steel areemployedalmostfor everyother type of structure which includes high-rise buildings, towers, bridges, infrastructure, support systems for equipment and machinery, heavy industrial building, heavy industrial plant, etc. Adhering to every structural specification, the dimensions for steel members formed by hot and cold rolled procedures are connected by welding or bolting flat and bent plates together. Frequently adoptedshapesaretheIshapedbeams, Hollow sections, angle, channel, and plates. 1.1 ADVANTAGES OF STEEL STRUCTURES Structures made from steel sections are quickly built at the project site because majority of building components could be prefabricated at the workshop or Steel manufacturing facility. The Expansion of any steel Structure can comparatively be very easy and fast. As steel can be molded into different shapes as a result repair & rehabilitation and/or retrofitting is conveniently possible. As the steel building components are prepared in the workshop, the erection of the structure at site is fast in comparison to other building materials. Because of their flexibility, they are excellent at resisting dynamic (changing) forces like wind or seismic forces. In earthquake zones, the fact that steel may bend without cracking serves as a warning. Thereisalargeselectionofpre- made structural sections, including I, C, and angle sections. They can be fashioned into any shape and covered with any kind of shape. Bolting, welding, and riveting are just a few of the connecting techniques that are accessible. we can also recycle steel. About one-third of the energy required to produce new steel from scrap steel is used in this process. 1.2 DISADVANTAGES OF STEEL STRUCTURES Before forming a structural system, analytical approaches and assumptions must be fairly clear and final. The time consumed to design a connection is longer than that of an RCC structure connection. The cost of structural steel (especially India) is higher than RCC. Skilled workforce is required. Steel has a property of becoming soft and melting when exposed to very high temperatures. Additional fire protection, such as spray on fireproofing, structural steel buildings can withstand high temperatures, which in turn enhances security. They tend to corrode in damp or marine environments. Hence, consistent care is needed.
  • 2. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2652 2. PROJECT STRUCTURAL SCHEME All structural design and analysis must adhere to the latest Provisions of the Indian Standard codes for Steel and RCC construction primarily IS 800:2007 and IS 456:2000. Special quality weld joints allowing 100% tension strength shall be required. Non-destructive testing techniquesshould be used for weld quality inspection and control. For slip- critical joints a slip factor of 0.5 shall be used in accordance with IS 4000 with specified surface treatment and preparation. 2.1. LOADS ON STRUCTURE Dead load Self-weight The unit weight of materials shall conform to IS 875 – Part 1. The self-weight ofstructureisautomaticallycalculatedbythe analysis software depending upon the cross-sectional area and density of each member. Density of R.C.C members = 25.0 kN/m3 Density of P.C.C members = 24.0 kN/m3 Density of structural steel = 78.5 kN/m3 Density of brick masonry walls (230/115 mm thick) = 20.0 kN/m3 Dry density of soil = 18.0 kN/m3 Density of saturated soil = 20.0 kN/m3 Density of water = 10.0 kN/m3 Density of floor finish = 24.0 kN/m3 Density of plaster = 24 kN/m3 Dead load on all floors Screed and Finishes (50mm)on typical floors = 0.05 m×25= 1.2 kN/m2 Service Loads = 1 kN/m2 Partition Walls = 1 kN/m2 Dead load on Terrace Screed and Finishes (150mm) = 0.150 m × 25 = 3 kN/m2 Service Loads = 1 kN/m2 Parapet Walls (1.5 meters) = 0.45 kN/m Live load Live load on all floors = 3 kN/m2 Live load on Terrace = 1.5 kN/m2 Basic Wind speed = 50m/s Seismic zone = IV Soil type = II Response reduction factor = 5 3. DESIGN OF METAL DECK SLAB The sheeting is designed for Self-weight of the Slab and Sheeting, and Erection loads Clear thickness of Concrete slab = 80.00 mm D overall thick =155 mm Avg thk. of Concrete slab within deck sheeting = 37.50 mm average thick =118 mm Service load =1 kN/m2 Partition load =1 kN/m2 Live load =3 kN/m2 Service+ partition + live load =5.000 kN/m2 Flooring thickness =50.00 mm Flooring density = 24.00 kN/m3 Erection Load = 5.00 kN/m2 Sheeting thickness = 1.00 mm Self-Weight of the sheeting = 11.96 kg/m2 Dead weight of deck slab =(0.08+0.0375) x 252+ 0.050 x 24+0.1196 = 4.3 kN/m2 Z of sheeting = 36.26 cm3 Spacing of beam (Maximum) = 2.00 m Load to be carried by sheeting = 9.3 kN/m2 (80+35)*.025+5(Erection)+50x0.024+.1196(self weight) Depth of the Decking Profile = 75.00 mm Flange width of supporting beam assumed = 140.00 mm Effective Span for the Decking Sheet Design = 1.94 m 230 75 Fig -1: Deck Sheet Profile B.M FACTOR FOR SHEETING = 8.00 Allowable bending stress in Sheeting = 165 N/mm2 (0.66 * 250MPa considered) Bending Moment (9.3 x 2 x 2 x 1000/8) = 4.65 kN-m Bending Stress (4650000/(36.26x1000))= 129.81 N/mm2 <165 O.k Check for Deflection Total Load = 9.3 kN/m/m SPAN = 2.00 m SPAN (Effective) = 1.94 m IXX = 1473000 mm4 Defl. Coeff. = 5/384 Limiting Deflection Ratio for Deck Sheet = 200
  • 3. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2653 Allowable Deflection = 9.68 mm Vertical Deflection = 5.76 mm (5x9.3x(1.935x1000)^4)/(384x200000x 1473000) <<9.68 O.K 4. DESIGN OF SECONDARY BEAM SPAN OF THE BEAM = 7.50 m Provide Beam as = ISMB350 Width of the falange = 140.00 mm Area of the section = 6671.00 mm2 Ixx of the section =136303000mm4 Zxx of the section = 778874 mm3 Rmin of the section = 28.40 mm Depth of the section = 350.00 mm Flange thickness = 14 mm Web thickness = 8 mm Flange width = 140 mm Design of beam by using Composite action Assumptions 1) Dead load of Concrete slab & self-weight of beam and construction load of 1.5 kn/sqm is taken by Steel beam only. 2) Only balance live load & flooring load is resisted by composite construction after the concrete is hardened. 3) Area of the concrete with in profile depth is ignored for effective width calculation of slab. 4) Design of shear connector as per IS:11384-1985 for ultimate shear capacity of concrete. Modulur Ratio = 280 / 3 s cbc, = 280 / 3 x 8.5= 10.98 Depth of Deck Sheeting = 70.00 mm Area of reinforcement perpendicular to Beam=2.50 cm2 (Ast provided in slab) Effective Width of Slab Lesser of the following 1) Span /4 = 7.5x1000/4 = 1875.00 mm 2) 12xslab thk.+Flange width = 12x80+140 = 1100.00 mm 3) Spacing of beams = 2000.00 mm So effective width = 1100.00 mm Transformed width = 1100/10.98 = 100.18 mm C.G from bottom = (6671x350x0.5+100.2x80x[350+75+80x0.5])/(6671+100.2x 80) = 333.27 mm Ixx of combined section 136303000 + 6671x(333.3-175)^2 + 100.2x80^3/12 + 100.2x80x(350+75+80x0.5-333.3)^2 = 4.47E+08 mm4 Zxx at bottom = 446757145.4/333.3 = 1.34E+06 mm3 100.2 80 75 14 350 333.27 140 Fig -2: I section with deck slab in equivalent steel area Stresses due to Dead weight + Construction live load (only Steel beam action) Udl on beam WITH construction load of 1.5 kn/sqm = 0.80 t/m {(80+35)x0.001x2.5+0.01196}x2+0.006671x7.85+0.15 Bending Moment 0.801x7.5x7.5/8 = 5.63t-m Bending stress =56340516.8/778874 = 72.34 N/mm2 Deflection in beam = 12.11 mm (5x0.80x10x(7500)^4)/(384x200000x136303000) Stresses due to Imposed Load (composite action) Additional Equivalent UDL due to Brick Wall = 0.00kN/m Additional live load is 5-1.5 = 3.5kn/sqm Udl on beam =(5-1.5 +0.05x24)x2 = 9.40 kN/m Bending Moment = 9.4x7.5x7.5/8 = 66.09 kN-m Bending Stress at bottom of steel =66.09375x 10000000/1340542.46 = 49.30 N/mm2 Total Bending Stresses = 72.34+49.30 = 121.64N/mm < 165 O.K Deflection due to balance Live load and finishing 5x9.4x(7500)^4/(384*200000x446757145.4) = 4.33 mm Deflection Factor for Dead Load = 1000.00 Allowable deflection =7500/1000 =7.50 mm (As Per IS 14687-1999 cl:7.5 (b) ) Total 'deflection' =4.3+12.11 = 16.44mm < 23.1 O.K Allowable deflection = 7500/325 = 23.08 mm Zxx at top =446757145/(350+75+80-333.3) =2.60E+06mm3 Bending compressive stress in concrete 66.1x1000000/(2601447.5x10.98) = 2.31 N/mm2
  • 4. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2654 < 8.33 O.K Allowable bending comp. Stress in concrete = 8.33 N/mm2 For M25 Grade = 25/3 (Cl. 13.0 IS:11384 -1985) Fig -3: Composite I section Check for Ultimate Limit state of Longitudinal Shear Shear Stud Spacing: Maximum Horizontal Shear (fcc) (Page No:7 IS:11384 - 1985)0.36*fckbXu = 0.36x25x1100x80/1000 = 792.00 kN Shear capacity of each stud = 31.42 kN Dia of stud = 20 mm Height of the stud = 100 mm No. of studs at cross section = 2 No. of studs =792/(2x31.4159265358979) = 12.61 Spacing of studs Reqired : 3750 / 12.6 = 297.50 mm Spacing of studs provided = 250.00 mm <600mm < 4 x 80mm Shear per Meter length (Q) =792 / 3.75 = 211.20 KN/M Shear resistance of slab is minimum of the following ( Page No:10 IS:11384 -1985) 0.232x2x80x SQRT(25)+0.1x2.5x500*2 = 435.60 kN/m 0.623x2x80x SQRT(25) = 498.40 kN/m 211.200<435.6O.K Check for Ultimate Limit state of Vertical Separation ( CL. 10. IS:11384-1985) Length of the shear connector = 100 mm > 50mm O.K. Projection of shear connector into the slab =100-0,100mm > 25mm O.K. Min. Diameter of Head = 1.5 xdia = 30 mm Design of Shear Studs Dia of stud =20.00 mm Yield stress of stud =245.00N/mm2 Maximum permissible shear stress =98.00 N/mm2 Area of stud =314.16 mm2 Shear capacity of stud =30.79 kN Thickness of slab =250.00 mm Floor thickness =50.00 mm Total Load 1.0DL+0.5LL+EQL =11.19 kN/m2 Length of beam =7.50 m Span of beam =2.00 m Total Load =167.92 kN Z = 0.24 I =1.50 Sa/g =2.50 R =5.00 Seismic coefficient,Ah =0.09 Horizontal force =22.67 kN Spacing of stud =250.00 mm No of studs provided =30.00 Say 30 Shear capacity of stud = 924 kN > 22.67kN OK 5. CONCLUSIONS Structures made from steel sections are quickly built at the project site because majority of building components could be prefabricated at the workshop or Steel manufacturing facility. The Expansion of any steel Structure can comparatively be very easy and fast. Steel structures have good scrap value with respect to RCC. In tubular structures, members are capable to resist both direction of lateral forces due to the good inertia propertyin both directions. Composite tubes constructions in columns is easy with respect to I section encased in concrete column. In the composite tube construction, no shuttering, de shuttering, and bar bending is required. Dynamic forces that change with time such as wind and/or seismic waves are smoothly resisted by the flexile nature of the steel. Only one third energy is required to create new steel from scrapped material than fresh steel alloy achieved from iron ore. REFERENCES [1] Duggal, S.K Limit state design of steel structures. 3- Ghobarah a. et al., “pushover analysis of steel frames”, (1997) [2] N Subramanian design of steel structures by Limit state method.
  • 5. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 07 | July 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 2655 [3] IS 1893(Part 1):2002, (2002), “Indian Standard criteria for earthquake resistant design of structures”, (5th revision). [4] IS 800: 2007, “Indian Standard criteria for design of steel structure. [5] Hassan, O.F., Goel, S.C.(1991).”Modelling of bracing members and seismic behavior of concentricallybraced steel frames”. [6] K.G.Vishwanath, “Seismic response of Steel braced reinforced concrete frames”, International journal of civil and structural engineering (2010) [7] Khatib, I. and Mahin, S., Dynamic inelastic behavior of chevron braced steel frames, Fifth Canadian Conference on Earthquake Engineering, Balkema, Rotterdam,1987, pages 211-220 [8] K.K.Sangle,K.M.Bajori,V.Mhalungkar,“Seismic AnalysisOf High Rise Steel Frame With And WithOutBracing”,2012 9-Mateescu, G., & Molodovan, A. Resarch on seismic behavior of steel structures.