SlideShare a Scribd company logo
1 of 40
Download to read offline
Technical Data
1
Grundfos SQ/SQE
Data Book
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
2
Technical Data
3
Table of Contents
SQ/SQE Features and Benefits ........................................................... pages 4-6
Applications.......................................................................................... pages 7-9
Communications .............................................................................. pages 10-13
Performance Data............................................................................. pages 15-31
Technical Data & Accessories......................................................... pages 32-36
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
4
SQ/SQE Submersible Pumps
SQ/SQE pumps are suitable for both continuous and
intermittent operation for a variety of applications:
· Domestic water supply
· Small waterworks
· Irrigation
· Tank applications
SQ, SQE pumps offer the following features:
· Dry-Run protection
· High efficiency pump and motor
· Excellent wear resistance, and sand handling
capabilities
· Protection against up-thrust
· Soft-start
· Over-voltage and under-voltage protection
· Overload protection
· Over-temperature protection
· High starting torque
Additionally, the SQE pumps offer:
· Constant pressure control
· Variable speed
· Electronic control and communication
The SQ and SQE pump models incorporate a totally new
motor design. With the use of permanent-magnet technol-
ogy within the motor, the SQ/SQE pumps deliver un-
matched performance. By combining permanent-magnet
motors and Grundfos’s own micro frequency converter, we
are now able to control and communicate with the pump in
ways never before possible. A few of the features that
come out this combination are Constant Pressure Control,
Soft-Start, and integrated Dry-Run protection. These are
just a few of the many features that the SQ/SQE pumps
can offer.
The SQ pump models are a simple pump that operates at
a constant speed much like today’s conventional pumps.
The difference between it and todays' pumps is you get all
the benefits of an electronically controlled permanent -
magnet motor that cannot be accomplished with a con-
ventional induction motor. The SQ pumps are available
for single phase power. They use a simple 2-wire design
making installation easy.
The SQE uses the Grundfos “Smart Motor”. Like the SQ
model, we still use the high efficiency permanent magnet
motor, but we give this motor the ability to communicate.
The “Smart Motor” communicates via the CU300 status
box through the power leads. It is not necessary to run
any additional wires down the well. By being able to
communicate with the pump you can have Constant
Pressure Control and the ability to change the pump
performance while the pump is installed in the well. Like
the SQ motor, this is also a 2-wire motor designed for
single-phase operation.
The CU300 status box also allows you to communicate
with the "Smart Motor" with the R100 infrared remote
control. The R100 gives you the ability to monitor and
setup your pumping system to meet the specific needs of
your application. It is also important to note the “Smart
Motor" can operate without the CU300, but you will loose
some of the functions that are only possible by using the
CU300.
The CU300 provides full control of the SQE pumps. If the
pump stops, the CU300 will illuminate a light on the front
panel. If you have an R100 you will be able to trouble
shoot the system and recall the last five causes of failure.
Pump and Motor Range
Pipe Connection
Operating Conditions
Type key
Example 10 SQ E 05 A 160 -NE
Nominal flow GPM
Type range
Electronic control/communication
Horsepower
Motor designation
Head in ft at nominal flow rate
Material specification
Features and Benefits
Product Description Material
SQ/SQE Pump 5,10,15,22,30 gpm Stainless steel
AISI 304
SQ-MS 3 Motor Single-phase Stainless steel
1/3 - 1.5 Hp AISI 304
SQE-MSE 3 Motor Single-phase Stainless steel
"Smart Motor" 1/3 - 1.5 Hp AISI 304
Pump Type Threaded Connection
SQ/SQE 5 1" NPT
SQ/SQE 10,15 1 1/4" NPT
SQ/SQE 22, 30 1 1/2" NPT
Flow velocity past motor Max. liquid temperature
0.0 f/s (Free convection) 86
o
F (30
o
C)
Min. 0.5 f/s 104
o
F (40
o
C)
Technical Data
5
Dry-Run Protection
The SQ and SQE incorporate integrated Dry-Run protec-
tion. When the water level falls below the inlet of the pump
the pump will shut off. After a period of time, the pump will
then automatically start up again.
For the SQ pumps the cut-off level is factory-set. For the
SQE pumps you must set this level by using a CU300 and
R100.
High Motor Efficiency
The SQ and SQE motors are based on a permanent
magnet rotor which produce high efficiency within a wide
load range. The high and flat efficiency curve of the
Permanent-Magnet motor allows for a coverage of a wide
power range with the same motor, as compared to con-
ventional AC motors. For SQE pumps, this means three
motors to cover the horsepower range from 1/3 to 1.5Hp.
High Pump Efficiency
The pump components are made from a 30% glass filled
engineered composite. The pumps are designed to
deliver at peak efficiency levels. Because of high pump
efficiencies, overall power consumption will be reduced.
Excellent Wear Resistance
The SQ/SQE pump design uses “floating” impellers. Each
impeller has its own tungsten carbide/ceramic bearing.
This design and the high quality materials make the pump
very wear resistant especially in sandy conditions.
Amps
sec.
Soft start
DOL
2
Protection against up-thrust
During start-up many pumps start in an up-thrust condi-
tion. To prevent damage caused by up-thrust a top
bearing has been placed in the motor to protect both the
pump and the motor against up-thrust.
Soft-Start
Both the SQ and SQE motors have a soft start because of
the integrated electronics. Soft start reduces the starting
current and gives the pump a smooth and steady accel-
eration.
The soft-start will reduce your chance of water hammer,
minimizes the risk of wear and prevent overloading of your
circuit during start-up.
High Starting Torque
Because of the permanent-magnet motor the SQ/SQE
pumps have excellent starting capabilities. The high
locked rotor torque produced by the PM motor provides a
starting torque that is 1.5 times greater than conventional
pump motors. Even if the voltage is low the PM motor will
still maintain a high starting torque.
Overvoltage and Undervoltage Protection
Overvoltage and undervoltage may occur at anytime
especially if you have an unstable voltage supply.
The integrated voltage protection of the SQ and SQE
motors protects the motors when the voltage falls outside
the permissible voltage range.
The 230V pump will cut out if voltage falls below 150V or
above 280V. The motor will automatically start when the
voltage is within the permissible voltage range. It is not
necessary to have additional voltage protection.
Overload Protection
When the pump load rises above the maximum amp level,
the motor will automatically compensate and reduce the
speed to maintain its maximum amp level. If the speed
drops to 65% of the nominal speed, the motor will shut off.
Features and Benefits
200 250 300 350 400 450 500 550 600 [W]
45
50
55
60
65
70
[%]
Conventional 1ph
Conventional 3ph
MS 3
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
6
0 Q [m‡/h]
0
[m]
H
65 %
100 %
Overtemperature Protection
Permanent-magnet motors emit very little heat because of
their high efficiency. The SQ and SQE motors are de-
signed with an internal circulation system to effectively
cool all the internal motor components.
As extra protection, the electronic unit also has a built-in
temperature sensor. When the temperature rises too high,
the motor will shut off; when the temperature drops, the
motor will automatically restart.
Reliability
The SQ and SQE motors have been designed to with-
stand the toughest of applications and provide reliability.
Some of those features are:
· Tungsten carbide/ceramic bearings
· Thrust bearings protecting against down-thrust
· Product lifetime equal or greater than conventional AC
motors and 4"pumps
Variable Speed
The SQE “Smart Motor” enables continuous variable
speed control within 65% - 100%(7000-10700 rpm) of
motor speed. The pump can be set to operate at any duty
point in the range between 65% and 100% of the pump's
performance curve. Your pump can then be adapted to
any specific requirement. The variable speed control
requires the CU300 control unit and the R100.
To help you decide on the proper speed, we have made
available a speed calculation program called “SQE –
Speed Calculation”. This program is available as an
option.
Installation
The SQ and SQE may be installed vertically or horizon-
tally.
Note: The pump must not fall below the horizontal level in
relation to the motor.
The following features ensure simple installation of the SQ
and SQE pumps:
· Built-in spring loaded check-valve
· Light weight makes it easy to install
· Fits in 3” or larger wells
For horizontal installation, a flow sleeve is recommended
in order to:
· Ensure sufficient flow
past the motor to provide
sufficient cooling
· Prevent the unit from
being buried in sand or
mud
Service
The modular design of the pump and motor makes it easy
to repair and service. The motor lead is also replaceable.
Features and Benefits
Variable Speed Range of Operation
Technical Data
7
SQ is the perfect pump for domestic water supply. The SQ is easy to sell, install and operate.
Replacement in Existing Installation
SQ and SQE pumps can be installed as replacement of a 4” submersible pump in an existing installation.
By replacing an existing 4” pump with an SQ or SQE, you not only get the most advanced pump on the market, but
you also have the ability to upgrade your system to a constant pressure system as shown on page 8.
Applications
SQ with Pressure Switch and Diaphragm Tank
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
8
Function and Benefits
Constant pressure can be maintained in the system to provide you with “city like” water pressure. A flow switch starts
the pump once the tap is opened. A preset pressure is maintained via the pressure sensor and the CU300. When the
flow switch detects no flow, the tank is filled with water and the pump stops.
If consumption is below 0.8 gpm, the CU300 will start the pump when the pressure is 7 psi below the set-point. The
pump will then stop when the pressure is 7 psi above the set-point.
When consumption is above 0.8 gpm, the CU300 will control the pump performance to keep the pressure within 3 psi
of the set-point.
Constant pressure control reduces pressure variations, and allows you to use a tank as small as 2 gal. Without loss of
comfort. In installations incorporating filters, pump operation will gradually adjust as the filter becomes plugged.
Applications
SQE with Constant Pressure Control
1 SQE Pump
2 Drop Pipe
3 Supply
4 Flow Switch
5 Pressure Transducer
6 Relief Valve
7 Diaphragm Tank
8 R100 Remote
9 CU300
Technical Data
9
Pumping from One Tank to Another
The SQE pump is ideal where there is a need to move water from one tank to another.
Applications
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
10
CU300 Status Box
The CU300 status box is a control and communication unit
especially developed for the SQE submersible pumps.
The CU300 status box provides:
· Easy adjustment to a specific well
· Full control of the SQE pumps
· Two-way communication with the SQE pumps
· Indicator lights on the front to indicate alarms
· The ability to start and stop the pump with the push of
a button
The CU300 communicates with the pump using the power
leads. It is not necessary to run any extra cables between
the pump and the CU300 status box.
The following alarms can be indicated by the CU300:
· No contact
· Overvoltage
· Undervoltage
· Dry-Run
· Speed reduction
· Overtemperature
· Overload
· Sensor alarm
The CU300 incorporates:
· External signal input for three sensors
· Relay output for external alarm indication
· Control according to the signals received, e.g. flow
pressure, water level and conductivity
The CU300 can communicate with the R100 infrared
remote control.
R100 Remote control
The R100 allows you to monitor the installation by reading
current operating parameters, such as:
· Power consumption
· Energy consumption
· Number of operating hours
It allows you to change factory settings. A number of
settings can be made, such as:
· Speed (performance)
· Constant pressure control mode
· De-watering function
· Automatic restart time
Communication CU300
9.1 4.5
7.7
Technical Data
11
R100 Menu Structure
0. General 2. Status 3. Limits 4. Installation1. Operation
1.1
1.2
1.3
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
3.12
4.92.9
4.10
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
12
R100 Menu Structure for the CU300
0. General
1. Operation
1.1 Set-point setting
1.2 Selection of operating mode
1.3 Alarm indication
2. Status
The indication of:
2.1 Actual operating mode
2.2 Actual and external set point
2.3 Actual motor temperature
2.4 Actual motor speed
2.5 Actual power input and accumulated motor power
consumption
2.6 Accumulated number of operating hours and
accumulated number of starts
2.7 Actual values of sensors 1 and 2 respectively
2.8 Actual values of the digital input
2.9 Accumulated flow, and the power used to pump 1
gal.
R100 allows you to make a number of settings:
3. Limits
The setting of:
3.1 Sensor 1
3.2 Min. and max. stop limit of sensor 1
3.3 Min. and max. warning limit of sensor 1
3.4 Min. and max. alarm limit of sensor 1
3.5 Sensor 2
3.6 Min. and max. stop limit of sensor 2
3.7 Min. and max. warning limit of sensor 2
3.8 Min. and max. alarm limit of sensor 2
3.9 Filling or emptying
3.10 Setting of the function of the digital sensor
connected to the digital input
3.11 The setting of the water quantity stop limit and the
setting of the sensor to detect water quantity
3.12 The setting of the temperature warning limits of
the motor electronics
4. Installation
4.1 Selection of controller
4.2 Setting of external set-point
4.3 Setting of automatic restart time
4.4 Allocation of individual start delays
4.5 Setting of the stop and run times for the de-water
ing function.
4.6 Setting of the minimum value of the pump power
input
4.7 Activating or deactivating the Dry-Run protection.
4.8 Setting of the maximum motor speed
4.9 Activating or deactivating the on/off-button on the
CU 300.
4.10 Allocation of number where more than one
CU 300 is installed.
Status report
All settings and measured values can be transferred to a
portable printer via wireless infrared communication and
be printed in a status report.
R100 Menu Structure
Technical Data
13
Examples of R100 displays
Menu OPERATION
Set-point Setting
From the factory, the pump is
set to maximum speed, 10,700
rpm. R100 allows you to
reduce the pump speed by
changing the setpoint. The
speed can be set from 7,000 –
10,700 rpm, at 100 rpm
intervals.
The unit of the set-point is automatically changed accord-
ing to the unit of the sensor connection to sensor input
no. 1.
EXAMPLE: Sensor input no. 1 is connected to a pressure
sensor using the unit feet (ft.) and the range 0 – 200.
Therefore, the set-point of display 1.1 can be set to
between 0 – 200 ft.
Menu STATUS
The displays appearing in this
menu are status displays only. You
cannot change settings in this
menu.
Accumulated Flow
In display 2.9, the water quantity (gal.) pumped is shown.
The value shown is the accumulated flow registered by
the sensor selected in display 3.11.
The power used to pump 1 gal. is shown in the display as
energy per gal. (kWh/gal.).
Accumulated Number of Operating Hours and Number
of Starts
The value of operating hours and
the number of starts are values
accumulated from the time of
installation and they cannot be
reset.
Both values are stored in the motor electronics, and are
kept even if the CU300 is replaced.
The number of operating hours is registered every two
minutes of continuous operation.
Menu LIMITS
The Setting of Sensor 1.
Depending on the type of sensor,
the following settings can be
made:
Sensor outputs:
(not active), 0-10V, 2-10V, 0-20
mA, 4-20mA.
Setting range unit: M3
/h, m, %,
gpm, ft.
R100
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
14
Technical Data
15
Grundfos SQ/SQE
Performance Data
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
16
SQ/SQE Data Easy Selection Chart 5SQ/SQE
5 SQ/SQE
SELECTION CHARTS FLOW RANGE PUMP OUTLET
(Ratings are in GALLONS PER MINUTE-GPM) (1.5 TO 8 GPM) 1" NPT
DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET
PUMP
MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100
0 8 7.5 6.7 5.7 4.4 2.6 0.4
20 6.5 5.5 4.2 2.3 0.1
5SQ/SQE03A-90 1/3 30 5.1 3.6 1.6
40 3.6 1.5
50 1
60
SHUT-OFF PSI: 97 89 78 71 20 11 2
0 8 7.7 7.3 6.7 6.1 5.5 4.7 3.7 2.6 1
20 7.1 6.6 6 5.3 4.5 3.5 2.2 0.6
5SQ/SQE03A-140 1/3 30 6.5 5.9 5.1 4.3 3.3 1.9
40 5.8 5.1 4.1 3.2 1.8
50 4.9 4 3 1.4
60 3.8 2.6 1
SHUT-OFF PSI: 82 74 65 56 48 39 30 22 13 4
0 7.9 7.5 7.1 6.7 6.2 5.6 5.1 4.4 3.6 2.6 1.1
20 7.8 7.4 7 6.5 6.1 5.5 4.9 4.2 3.3 2.3 0.8
5SQ/SQE05A-180 1/2 30 7.3 6.9 6.5 5.9 5.4 4.8 4.1 3.2 2 0.2
40 6.9 6.5 5.9 5.4 4.7 4 3.1 2 0.1
50 6.3 5.8 5.3 4.6 3.8 2.9 1.6
60 5.7 5.1 4.4 3.6 2.6 1.2
SHUT-OFF PSI: 110 102 93 84 76 67 58 50 41 33 24 15 7
0 8 7.7 7.3 6.9 6.5 6.1 5.6 5.1 4.6 4.1 3.4 2.8 0.8
20 8 7.6 7.1 6.8 6.3 5.9 5.4 5 4.5 3.9 3.3 2.6 1.8 0.6
5SQ/SQE05B-230 1/2 30 7.9 7.5 7.1 6.7 6.3 5.9 5.4 4.9 4.4 3.8 3.1 2.4 1.5
40 7.5 7.1 6.7 6.3 5.8 5.4 4.9 4.3 3.7 3.1 2.3 1.4
50 7 6.6 6.2 5.8 5.3 4.8 4.2 3.6 2.9 2.2 1.2
60 6.5 6.1 5.6 5.1 4.6 4.1 3.4 2.8 2 0.9
SHUT-OFF PSI: 143 134 126 117 108 100 91 82 74 65 56 48 39 30 22 4
0 8 7.8 7.5 7.2 6.8 6.5 6.1 5.8 5.3 4.9 4.4 3.4 1.2
20 8 7.7 7.4 7.1 6.7 6.4 6 5.6 5.2 4.8 4.3 3.8 3.2 1.8
5SQ/SQE05B-270 1/2 30 8 7.7 7.3 7 6.7 6.3 5.9 5.5 5.1 4.7 4.2 3.7 3.1 2.4 0.8
40 8 7.7 7.3 7 6.7 6.3 5.9 5.5 5.1 4.7 4.2 3.7 3.1 2.4 1.6
50 7.6 7.3 6.9 6.6 6.2 5.9 5.2 5 4.6 4.1 3.5 3 2.2 1.5 0.6
60 7.2 6.9 6.5 6.1 5.7 5.3 4.9 4.4 3.9 3.4 2.7 2.1 1.2 0.2
SHUT-OFF PSI: 175 167 158 149 141 132 123 115 106 97 89 80 71 63 54 37 11
0 7.9 7.6 7.3 7 6.7 6.4 6.1 5.7 5.4 4.6 3.4 1.6
20 7.8 7.5 7.2 6.9 6.6 6.3 6 5.6 5.3 4.9 4.5 3.9 2.1
5SQ/SQE07B-320 3/4 30 8 7.7 7.5 7.1 6.9 6.5 6.2 5.9 5.5 5.2 4.8 4.4 4 3.1 1.2
40 8 7.7 7.5 7.1 6.9 6.5 6.2 5.9 5.5 5.2 4.8 4.4 4 3.5 2.5 0.2
50 7.9 7.6 7.4 7.1 6.8 6.5 6.1 5.8 5.5 5.1 4.7 4.3 3.9 3.5 3 1.9
60 7.6 7.3 7 6.7 6.4 6 5.7 5.4 5 4.6 4.2 3.8 3.3 2.8 2.2 0.8
SHUT-OFF PSI: 249 240 232 223 214 206 197 188 180 171 162 154 145 136 128 110 84 58
0 8 7.7 7.4 7.2 6.9 6.6 6.3 6 5.4 4.4 3.3 1.9
20 7.9 7.6 7.3 7.1 6.8 6.5 6.2 5.9 5.6 5.3 4.7 3.6 2.3
5SQ/SQE10C-360 1 30 8 7.8 7.6 7.3 7 6.7 6.5 6.2 5.9 5.6 5.3 4.9 4.3 3.1 1.6
40 8 7.8 7.5 7.3 7 6.7 6.5 6.1 5.9 5.6 5.3 4.9 4.6 3.9 2.6 0.8
50 0.8 7.8 7.5 7.2 7 6.7 6.4 6.1 5.8 5.5 5.2 4.9 4.5 4.2 3.3 2
60 8 7.7 7.4 7.2 6.9 6.6 6.3 6 5.7 5.4 5.1 4.8 4.4 4.1 3.7 2.9 1.2
SHUT-OFF PSI: 234 227 219 210 201 193 184 175 167 158 149 141 132 123 115 97 71 46 20
0 7.9 7.6 7.4 7.1 6.8 6.5 6 5.1 4.2 3.2 1.4
20 7.8 7.6 7.3 7 6.7 6.5 6.2 5.9 5.3 3.6 3.4 2.3
5SQ/SQE10C-410 1 30 8 7.8 7.5 7.3 7 6.7 6.4 6.1 5.9 5.6 5 4.1 3 1.7
40 8 7.8 7.5 7.3 7 6.7 6.4 6.1 5.8 5.6 5.3 4.7 3.7 2.6 1.1
50 8 7.7 7.4 7.2 6.9 6.6 6.3 6.1 5.8 5.5 5.2 4.9 4.3 3.3 2.1
60 7.9 7.6 7.4 7.1 6.8 6.5 6.3 6 5.7 5.4 5.1 4.8 4.5 3.9 2.8 1.4
SHUT-OFF PSI: 249 240 232 223 214 206 197 188 180 171 162 154 145 128 102 76 50 15
0 7.9 7.6 7.4 7.1 6.6 5.8 5 4.1 2.9
20 7.9 7.6 7.3 7 6.7 6.5 6 5.1 4.3 3.4 2
5SQ/SQE10C-450 1 30 8 7.8 7.5 7.2 6.9 6.7 6.4 6.1 5.6 4.8 4 3.1 1.5
40 8 7.8 7.5 7.2 7 6.7 6.4 6.2 5.9 5.4 4.5 3.7 2.7 0.8
50 8 7.7 7.5 7.2 6.9 6.6 6.4 6.1 5.9 5.6 5 4.2 3.3 2.3
60 7.9 7.6 7.4 7.1 6.8 6.6 6.3 6 5.8 5.5 5.2 4.7 3.8 7.9 1.7
SHUT-OFF PSI: 264 255 247 238 229 221 212 203 194 186 177 160 134 108 82 48
Technical Data
17
SQ/SQE Data Easy Selection Chart 10SQ/SQE
10 SQ/SQE
SELECTION CHARTS FLOW RANGE PUMP OUTLET
(Ratings are in GALLONS PER MINUTE-GPM) (3 TO 15 GPM) 1 1/4" NPT
DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET
PUMP
MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100
0 14.8 13.5 12.5 11.0 9.0 6.0
20 13.5 12.0 10.5 8.5 5.0
10SQ/SQE03A-110 1/3 30 11.8 10.0 8.0
40 10.0 8.0
50
60
SHUT-OFF PSI: 56 48 35 30 17 13 4
0 14.8 14.0 13.0 12.0 11.0 10.0 8.0 5.0
20 14.6 13.8 13.0 12.0 11.0 9.5 7.5 4.0
10SQ/SQE05A-160 1/2 30 13.5 12.8 11.8 10.5 9.0 7.0 2.0
40 12.8 11.8 10.5 9.0 7.0 2.0
50 11.5 10.2 8.5 6.0
60 10.0 8.0 5.0
SHUT-OFF PSI: 84 76 67 58 50 41 32 24 15 6
0 14.8 14.0 13.5 12.8 12.0 11.0 10.0 9.0 7.0 5.0
20 14.5 14.0 13.3 12.5 11.8 10.8 9.8 8.5 6.5 4.0
10SQ/SQE05B-200 1/2 30 14.5 13.8 11.8 12.5 11.5 10.5 9.5 8.0 6.0 3.0
40 13.8 13.0 12.5 11.5 10.5 9.5 8.0 6.0 3.0
50 13.0 12.0 11.5 10.5 9.0 7.5 5.5 1.5
60 12.0 11.0 10.0 9.0 7.0 5.0
SHUT-OFF PSI: 113 104 95 87 78 69 61 52 43 35 26 17 7
0 14.6 14.0 13.5 13.0 12.4 11.5 11.0 10.0 9.0 8.0 6.5 2.5
20 15.0 14.5 14.0 13.5 12.8 12.2 11.5 10.8 9.8 8.8 7.8 6.4 4.5 2.0
10SQ/SQE07B-240 3/4 30 15.0 14.3 13.8 13.3 12.8 12.0 11.3 10.5 9.5 8.5 7.5 6.0 4.0
40 14.5 13.8 13.3 12.8 12.0 11.3 10.5 9.5 8.5 7.5 6.0 4.0
50 13.8 13.0 12.5 11.8 11.0 10.3 7.5 8.3 7.0 5.5 3.5
60 13.0 12.4 11.7 11.0 10.0 9.0 8.0 6.7 5.0 2.5
SHUT-OFF PSI: 143 134 126 117 108 100 91 82 74 65 56 48 39 30 22 4
0 14.7 14.3 13.8 13.3 12.8 12.3 11.8 11.0 10.5 9.5 7.7 3.0
20 15.0 14.5 14.2 13.7 13.2 12.8 12.3 11.5 10.8 10.5 9.5 8.5 7.5 4.5
10SQ/SQE10C-290 1 30 15.0 14.5 14.0 13.7 13.2 12.7 12.0 11.5 10.8 10.0 9.3 8.3 7.2 5.8 1.5
40 15.0 14.5 14.0 13.7 13.2 12.5 12.0 11.5 10.8 10.0 9.3 8.3 7.3 5.8 4.0
50 15.0 14.5 14.0 13.0 12.5 12.0 11.2 10.5 9.8 9.0 8.0 7.0 5.5 3.5 1.0
60 13.8 13.3 12.8 12.3 11.8 11.0 10.5 9.6 8.8 7.7 6.5 5.0 3.0
SHUT-OFF PSI: 173 165 156 147 139 130 121 113 104 95 87 78 69 61 52 35 7
0 14.7 14.4 14.0 13.5 13.0 12.7 12.2 11.6 11.0 9.8 7.2 3.0
20 15.0 14.7 14.3 13.8 13.5 13.0 12.5 12.0 11.5 10.8 10.3 9.5 8.0 4.5
10SQ/SQE10C-330 1 30 15.0 14.5 14.2 13.8 13.3 12.8 12.5 11.8 11.3 10.8 10.2 9.5 8.8 6.8 2.2
40 15.0 14.6 14.2 13.8 13.4 12.8 12.4 12.0 11.4 10.8 10.2 9.5 8.7 7.8 5.5
50 14.8 14.5 14.0 13.7 13.2 12.7 12.2 11.7 11.2 10.5 10.0 9.3 8.5 7.5 6.6 3.5
60 14.4 14.0 13.5 13.0 12.6 12.2 11.5 11.0 10.5 9.7 9.0 8.2 7.3 6.1 4.8 1.2
SHUT-OFF PSI: 203 195 186 177 169 160 152 143 134 126 117 108 100 91 82 65 39 13
0 15.0 14.7 14.3 14.0 13.7 13.3 12.8 12.5 12.0 11.0 9.3 7.0 3.5
20 15.0 14.6 14.3 13.8 13.5 13.3 12.8 12.3 12.0 11.5 11.0 9.8 7.8 4.7
10SQ/SQE15C-380 1 1/2 30 15.0 14.5 14.3 13.8 13.5 13.3 12.8 12.3 11.8 11.3 10.8 10.3 9.0 6.5 3.0
40 14.8 14.5 14.3 13.8 13.5 13.0 12.7 12.3 11.8 11.3 10.8 10.3 9.8 8.3 5.5 1.0
50 14.8 14.5 14.1 13.7 13.3 13.0 12.5 12.2 11.7 11.2 10.7 10.2 9.5 8.8 7.2 4.0
60 14.7 14.4 14.0 13.7 13.3 13.0 12.5 12.0 11.5 11.0 10.5 10.0 9.4 8.7 8.0 6.0 2.0
SHUT-OFF PSI: 234 225 216 208 199 191 182 173 165 156 147 138 130 121 113 95 69 43 30
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
18
15SQ/SQE Easy Selection Chart SQ/SQE Data
15 SQ/SQE
SELECTION CHARTS FLOW RANGE PUMP OUTLET
(Ratings are in GALLONS PER MINUTE-GPM) (4 TO 20 GPM) 1 1/4" NPT
DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET
PUMP
MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100
0 19.5 16.5 13 8.5
20 15.5 12 7
15SQ/SQE03A-70 1/3 30 11 5
40 5
50
60
SHUT-OFF PSI: 41 32 24 15 7
0 19.5 17.5 16 13.5 11 7.5
20 19 17.5 15.5 13 10.5 6.5
15SQ/SQE05A-110 1/2 30 17 14.5 12.5 9.5
40 14.5 12.5 9.5
50 11.5 8.5
60 7.5
SHUT-OFF PSI: 65 56 48 39 30 22 13 4
0 19 18 17 15.5 14 12 10 7
20 19 18 16.5 15 13.5 11.5 8.5 6
15SQ/SQE05B-150 1/2 30 19 18 16.5 15 13 11 8.5 4.5
40 17.5 16.5 15 13 11 8.5 4.5
50 16.5 14.5 12.5 10.5 7.5 3
60 14 12 10 7
SHUT-OFF PSI: 95 87 78 69 61 52 43 35 26 17 7
0 19.5 18.5 17.5 16.5 15.5 14 12.5 11 9 6.5
20 20 19 18 17 16.5 15 13.5 12.5 10.5 8.5 5.5
15SQ/SQE07B-180 3/4 30 20 19 18 17 16 14.5 13.5 12 10 8
40 19 18 17 16 14.5 13.5 12 10 8
50 17.5 17 15.5 14.5 13 11.5 9.5 7
60 16.5 15.5 14 12.5 11 9 6.5
SHUT-OFF PSI: 117 108 100 91 82 74 65 56 48 39 30 22 15 4
0 19.5 18.5 17.5 17 16 15 14 13 11.5 10 6
20 20 19 18.5 17.5 16.5 15.5 14.5 13.5 12.5 11 9.5 8 5.5
15SQ/SQE10C-220 1 30 20 19 18.5 17.5 16.5 15.5 14.5 13.5 12.5 11 9.5 7.5 4
40 20 19 18.5 17.5 16.5 15.5 14.5 13.5 12.5 11 9.5 7.5 4
50 19 18 17 16 15 14 13 12 10.5 9 6.5
60 18 17 16 15 14 13 11.5 10 8.5 6
SHUT-OFF PSI: 145 136 128 119 110 102 93 84 76 67 58 50 41 32 24 6
0 20 19.5 18 17.5 16.5 15.5 15 14 13 11 5.5
20 20 19.5 18.5 18 17 16.5 15.5 15 14 13 11.5 10.5 6.5
15SQ/SQE10C-250 1 30 19.5 19 18.5 18 17 16 15.5 14.5 13.5 12.5 11.5 10.5 9 4
40 20 19 18.5 18 17 16.5 15.5 14.5 13.5 12.5 11.5 10.5 9 7
50 19.5 19 18.5 17.5 17 16 15 14.5 13.5 12.5 11 10 8.5 6.5
60 19 18 17.5 17 16 15 14 13 12 11 9.5 8 6
SHUT-OFF PSI: 171 162 154 145 136 128 119 110 102 93 84 76 67 58 50 32 6
0 20 19.5 18.5 18 17.5 17 16.5 15.5 15 13.5 10.5 5.5
20 20 19 18.5 18 17.5 17 16 15.5 14.5 14 13 11 7
15SQ/SQE15C-290 1 1/2 30 19.5 19 18.5 18 17.5 16.5 16 15.5 14.5 13.5 13 12 8.5
40 19.5 19 18.5 18 17.5 16.5 16 15.5 14.5 14 13 12 11 8.5
50 20 19.5 19 18.5 17.5 17 16.5 16 15 14.5 13.5 12.5 11.5 10.5 9.5 6
60 19.5 18.5 18 17.5 17 16.5 15.5 15 14 13.5 12.5 11.5 10.5 9 7.5
SHUT-OFF PSI: 197 188 180 171 162 154 145 136 128 119 110 102 93 84 76 58 32 6
Technical Data
19
SQ/SQE Data Easy Selection Chart 22SQ/SQE
22 SQ/SQE
SELECTION CHARTS FLOW RANGE PUMP OUTLET
(Ratings are in GALLONS PER MINUTE-GPM) (7 TO 33 GPM) 1 1/2" NPT
DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET
PUMP
MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100
0 31.5 23
20
22SQ/SQE03A-40 1/3 30
40
50
60
SHUT-OFF PSI: 17 7
0 31.5 27.5 22.5 19.5
20 26.5 21 11
22SQ/SQE05A-80 1/2 30 19.5 6.5
40 6.5
50
60
SHUT-OFF PSI: 41 32 24 15 7
0 33.0 31.0 28.5 25.5 22 17 7
20 30.5 28 21 15 3
22SQ/SQE05B-120 1/2 30 27 24 20 13
40 24 20 13
50 18.5 10
60 17
SHUT-OFF PSI: 65 56 48 39 30 22 13 4
0 32 30.5 28.5 26.5 24 21 17.5 12 3
20 32 31.5 28 26 23.5 20.5 16.5 10.5
22SQ/SQE07B-160 3/4 30 29.5 27.5 25.5 22.5 19.5 15 8.5
40 27.5 25.5 22.5 19.5 15.0 8.5
50 24.5 22 18.5 14 6
60 21 17.5 12 3
SHUT-OFF PSI: 89 80 71 63 54 45 37 28 19 11 2
0 33 31.5 30.5 29 27.5 25.5 23.5 21 18 14.5 8
20 32.5 31.5 30 28.5 27 25 23 20.5 17.5 13 4
22SQ/SQE10C-190 1 30 31 29.5 28 26.5 24.5 22 20 16.5 12
40 29.5 28 26.5 24.5 22 20 16.5 12
50 27.5 26 24 21.5 19 15.5 1
60 25.5 23.5 21 18 14 8
SHUT-OFF PSI: 107 99 90 81 73 64 55 47 38 29 21 12 4
0 32.5 31.5 30 29 27.5 26 24.5 23 21 18.5 15.5 11.5
20 32.5 31 30 28.5 27.5 25.5 24 22.5 20.5 17.5 14.5 10
22SQ/SQE15C-220 1 1/2 30 32 31 29.5 28.5 27 25.5 23.5 22 19.5 17 14 9
40 31 29.5 28.5 27 25.5 23.5 22.0 19.5 17 14 9
50 29.5 28 26.5 25.0 23.5 21.5 19.0 16.5 12.5 6.5
60 27.5 26.0 24.5 23.0 21.0 18.5 15.5 11.5
SHUT-OFF PSI: 130 121 113 104 95 87 78 69 61 52 43 35 26 17 9
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
20
30SQ/SQE Easy Selection Chart SQ/SQE Data
30 SQ/SQE
SELECTION CHARTS FLOW RANGE PUMP OUTLET
(Ratings are in GALLONS PER MINUTE-GPM) (8 TO 42 GPM) 1 1/2 " NPT
DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET
PUMP
MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100
0 40.0 30.5 11.0
20
30SQ/SQE05A-40 1/2 30
40
50
60
SHUT-OFF PSI: 20 11 2
0 41 36.5 31 23 9
20 35.5 29 20 4
30SQ/SQE05B-90 1/2 30 27.5 17
40 17
50
60
SHUT-OFF PSI: 48 39 30 22 13 4
0 41.5 38.5 35.5 31.5 27.0 21.0 11.0
20 40.5 37.5 34.5 30.5 25.5 19.0 8.0
30SQ/SQE10C-130 1 30 37.0 33.5 29.5 24.0 17.0 4.0
40 33.5 29.5 24.0 17.0 4.0
50 28.5 22.5 14.0
60 21.0 11.0
SHUT-OFF PSI: 76 67 58 50 41 32 24 15 7
0 41.5 39.5 37 35 32 28.5 24.5 19 11.5
20 41 39 36.5 34 31 27.5 23.5 17.5 9.5
30SQ/SQE15C-170 1 1/2 30 40.5 38.5 36 33 30 26.5 22 16 6
40 38.5 36 33 30 26.5 22 16 6
50 35.5 32.5 29.5 25.5 20.5 14 3
60 32 28.5 24.5 19 11.5
SHUT-OFF PSI: 104 95 87 78 69 61 52 43 35 26 17 9
Technical Data
21
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
22
0 1 2 3 4 5 6 7 8
0
100
200
300
400
500
600
700
800
5 GPMModels 5 SQ/SQE
FLOW RANGE: 1.5 - 8 GPM OUTLET SIZE: 1" NPT NOMINAL DIA. 3"
5SQ/SQE03A-90
5SQ/SQE05A-180
5SQ/SQE05B-230
5SQ/SQE05B-270
5SQ/SQE07B-320
5SQ/SQE10C-360
5SQ/SQE10C-410
5SQ/SQE10C-450
5SQ/SQE03A-140
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
Technical Data
23
5 GPM Models 5 SQ/SQE
DIMENSIONS AND WEIGHTS
NOTES: All models suitable for use in 3" wells, unless otherwise noted.
Weights include pump end with motor in lbs.
MATERIALS OF CONSTRUCTION
NOTES: Specifications subject to change without notice.
COMPONENT SPLINED SHAFT
Valve Casing Polyamide
Discharge Chamber 304 Stainless Steel
Valve Guide Polyamide
Valve Spring 316LN Stainless Steel
Valve Cone Polyamide
Valve Seat NBR Rubber
O-ring NBR Rubber
Lock ring 310 Stainless Steel
Top Bearing NBR Rubber
Top Chamber Polyamide
Guide Vanes Polyamide
Impeller Polyamide w/tungsten carbide bearings
Bottom Chamber Polyamide
Neck Ring Polyamide
Bearing Ceramic
Suction Interconnector Polyamide
Ring 304 Stainless Steel
Pump Sleeve 304 Stainless Steel
Cone for pressure equalization Polyamide
Spacer Polyamide
Sand Trap 316 Stainless Steel
Shaft w/coupling 304 Stainless Steel
Cable Guard 304 Stainless Steel
Fig. A
1" NPT
MOTOR DISCH. DIMENSIONS IN INCHES APPROX.
MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT.
5SQ/SQE03A-90 A 1/3 A 3" 1" NPT 30.4 19.8 10.6 2.6 2.9 12
5SQ/SQE03A-140 A 1/3 A 3" 1" NPT 30.4 19.8 10.6 2.6 2.9 12
5SQ/SQE05A-180 A 1/2 A 3" 1" NPT 31.5 19.8 11.6 2.6 2.9 12
5SQ/SQE05B-230 A 1/2 B 3" 1" NPT 33.6 19.8 13.7 2.6 2.9 13
5SQ/SQE05B-270 A 1/2 B 3" 1" NPT 33.6 19.8 13.7 2.6 2.9 13
5SQ/SQE07B-320 A 3/4 B 3" 1" NPT 34.6 19.8 14.8 2.6 2.9 13
5SQ/SQE10C-360 A 1 C 3" 1" NPT 38.2 21.3 16.9 2.6 2.9 16
5SQ/SQE10C-410 A 1 C 3" 1" NPT 38.2 21.3 16.9 2.6 2.9 16
5SQ/SQE10C-450 A 1 C 3" 1" NPT 39.3 21.3 18.0 2.6 2.9 16
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
24
0 2 4 6 8 10 12 14
0
100
200
300
400
500
600
10 GPM
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Models 10 SQ/SQE
FLOW RANGE: 3 - 15 GPM OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
10SQ/SQE03A-110
10SQ/SQE05A-160
10SQ/SQE05B-200
10SQ/SQE07B-240
10SQ/SQE10C-290
10SQ/SQE10C-330
10SQ/SQE15C-380
PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
Technical Data
25
Fig. A
10 GPM Models 10 SQ-SQE
DIMENSIONS AND WEIGHTS
NOTES: All models suitable for use in 3" wells, unless otherwise noted.
Weights include pump end with motor in lbs.
MATERIALS OF CONSTRUCTION
NOTES: Specifications subject to change without notice.
1 1/4" NPT
COMPONENT SPLINED SHAFT
Valve Casing Polyamide
Discharge Chamber 304 Stainless Steel
Valve Guide Polyamide
Valve Spring 316LN Stainless Steel
Valve Cone Polyamide
Valve Seat NBR Rubber
O-ring NBR Rubber
Lock ring 310 Stainless Steel
Top Bearing NBR Rubber
Top Chamber Polyamide
Guide Vanes Polyamide
Impeller Polyamide w/tungsten carbide bearings
Bottom Chamber Polyamide
Neck Ring Polyamide
Bearing Ceramic
Suction Interconnector Polyamide
Ring 304 Stainless Steel
Pump Sleeve 304 Stainless Steel
Cone for pressure equalization Polyamide
Spacer Polyamide
Sand Trap 316 Stainless Steel
Shaft w/coupling 304 Stainless Steel
Cable Guard 304 Stainless Steel
MOTOR DISCH. DIMENSIONS IN INCHES APPROX.
MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT.
10SQ/SQE03A-110 A 1/3 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12
10SQ/SQE05A-160 A 1/2 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12
10SQ/SQE05B-200 A 1/2 B 3" 1 1/4" NPT 31.5 19.8 11.6 2.6 2.9 13
10SQ/SQE07B-240 A 3/4 B 3" 1 1/4" NPT 33.6 19.8 13.7 2.6 2.9 13
10SQ/SQE10C-290 A 1 C 3" 1 1/4" NPT 35.0 21.3 13.7 2.6 2.9 16
10SQ/SQE10C-330 A 1 C 3" 1 1/4" NPT 36.1 21.3 14.8 2.6 2.9 16
10SQ/SQE15C-380 A 1 1/2 C 3" 1 1/4" NPT 38.2 21.3 16.9 2.6 2.9 16
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
26
0 2 4 6 8 10 12 14 16 18 20
0
100
200
300
400
500
15 GPM
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Models 15 SQ/SQE
FLOW RANGE: 4 - 20 GPM OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3"
15SQ/SQE03A-70
15SQ/SQE05A-110
15SQ/SQE05B-150
15SQ/SQE07B-180
15SQ/SQE10C-220
15SQ/SQE10C-250
15SQ/SQE15C-290
PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
Technical Data
27
NOTES: All models suitable for use in 3" wells, unless otherwise noted.
Weights include pump end with motor in lbs.
Fig. A
15 GPM Models 15 SQ/SQE
DIMENSIONS AND WEIGHTS
MATERIALS OF CONSTRUCTION
NOTES: Specifications subject to change without notice.
1 1/4" NPT
COMPONENT SPLINED SHAFT
Valve Casing Polyamide
Discharge Chamber 304 Stainless Steel
Valve Guide Polyamide
Valve Spring 316LN Stainless Steel
Valve Cone Polyamide
Valve Seat NBR Rubber
O-ring NBR Rubber
Lock ring 310 Stainless Steel
Top Bearing NBR Rubber
Top Chamber Polyamide
Guide Vanes Polyamide
Impeller Polyamide w/tungsten carbide bearings
Bottom Chamber Polyamide
Neck Ring Polyamide
Bearing Ceramic
Suction Interconnector Polyamide
Ring 304 Stainless Steel
Pump Sleeve 304 Stainless Steel
Cone for pressure equalization Polyamide
Spacer Polyamide
Sand Trap 316 Stainless Steel
Shaft w/coupling 304 Stainless Steel
Cable Guard 304 Stainless Steel
MOTOR DISCH. DIMENSIONS IN INCHES APPROX.
MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT.
15SQ/SQE03A-70 A 1/3 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12
15SQ/SQE05A-110 A 1/2 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12
15SQ/SQE05B-150 A 1/2 B 3" 1 1/4" NPT 31.5 19.8 11.6 2.6 2.9 13
15SQ/SQE07B-180 A 3/4 B 3" 1 1/4" NPT 33.6 19.8 13.7 2.6 2.9 13
15SQ/SQE10C-220 A 1 C 3" 1 1/4" NPT 35.0 21.3 13.7 2.6 2.9 16
15SQ/SQE10C-250 A 1 C 3" 1 1/4" NPT 36.1 21.3 14.8 2.6 2.9 16
15SQ/SQE15C-290 A 1 1/2 C 3" 1 1/4" NPT 38.2 21.3 16.9 2.6 2.9 16
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
28
0 5 10 15 20 25 30
0
50
100
150
200
250
300
350
22 GPM
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Models 22 SQ/SQE
FLOW RANGE: 7 - 33 GPM OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
22SQ/SQE03A-40
22SQ/SQE05A-80
22SQ/SQE05B-120
22SQ/SQE07B-160
22SQ/SQE10C-190
22SQ/SQE15C-220
PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
Technical Data
29
NOTES: All models suitable for use in 3" wells, unless otherwise noted.
Weights include pump end with motor in lbs.
Fig. A
22 GPM Models 22 SQ/SQE
DIMENSIONS AND WEIGHTS
MATERIALS OF CONSTRUCTION
NOTES: Specifications subject to change without notice.
1 1/2" NPT
MOTOR DISCH. DIMENSIONS IN INCHES APPROX.
MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT.
22SQ/SQE03A-40 A 1/3 A 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 12
22SQ/SQE05A-80 A 1/2 A 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 12
22SQ/SQE05B-120 A 1/2 B 3" 1 1/2" NPT 31.5 19.8 11.6 2.6 2.9 13
22SQ/SQE07B-160 A 3/4 B 3" 1 1/2" NPT 33.6 19.8 13.7 2.6 2.9 13
22SQ/SQE10C-190 A 1 C 3" 1 1/2" NPT 38.2 21.3 16.9 2.6 2.9 16
22SQ/SQE15C-220 A 1 1/2 C 3" 1 1/2" NPT 38.2 21.3 16.9 2.6 2.9 16
COMPONENT SPLINED SHAFT
Valve Casing Polyamide
Discharge Chamber 304 Stainless Steel
Valve Guide Polyamide
Valve Spring 316LN Stainless Steel
Valve Cone Polyamide
Valve Seat NBR Rubber
O-ring NBR Rubber
Lock ring 310 Stainless Steel
Top Bearing NBR Rubber
Top Chamber Polyamide
Guide Vanes Polyamide
Impeller Polyamide w/tungsten carbide bearings
Bottom Chamber Polyamide
Neck Ring Polyamide
Bearing Ceramic
Suction Interconnector Polyamide
Ring 304 Stainless Steel
Pump Sleeve 304 Stainless Steel
Cone for pressure equalization Polyamide
Spacer Polyamide
Sand Trap 316 Stainless Steel
Shaft w/coupling 304 Stainless Steel
Cable Guard 304 Stainless Steel
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
30
0 5 10 15 20 25 30 35 40
0
50
100
150
200
250
300
30 GPM
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Models 30 SQ/SQE
FLOW RANGE: 8 - 42 GPM OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3"
30SQ/SQE05A-40
30SQ/SQE05B-90
30SQ/SQE10C-130
30SQ/SQE15C-170
PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
Technical Data
31
NOTES: All models suitable for use in 3" wells, unless otherwise noted.
Weights include pump end with motor in lbs.
Fig. A
30 GPM Models SQ-SQE
DIMENSIONS AND WEIGHTS
MATERIALS OF CONSTRUCTION
NOTES: Specifications subject to change without notice.
1 1/2" NPT
COMPONENT SPLINED SHAFT
Valve Casing Polyamide
Discharge Chamber 304 Stainless Steel
Valve Guide Polyamide
Valve Spring 316LN Stainless Steel
Valve Cone Polyamide
Valve Seat NBR Rubber
O-ring NBR Rubber
Lock ring 310 Stainless Steel
Top Bearing NBR Rubber
Top Chamber Polyamide
Guide Vanes Polyamide
Impeller Polyamide w/tungsten carbide bearings
Bottom Chamber Polyamide
Neck Ring Polyamide
Bearing Ceramic
Suction Interconnector Polyamide
Ring 304 Stainless Steel
Pump Sleeve 304 Stainless Steel
Cone for pressure equalization Polyamide
Spacer Polyamide
Sand Trap 316 Stainless Steel
Shaft w/coupling 304 Stainless Steel
Cable Guard 304 Stainless Steel
MOTOR DISCH. DIMENSIONS IN INCHES APPROX.
MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT.
30SQ/SQE05A-40 A 1/2 A 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 12
30SQ/SQE05B-90 A 1/2 B 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 13
30SQ/SQE10C-130 A 1 C 3" 1 1/2" NPT 35.0 21.3 13.7 2.6 2.9 13
30SQ/SQE15C-170 A 1 1/2 C 3" 1 1/2" NPT 35.0 21.3 13.7 2.6 2.9 16
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
32
Grundfos SQ/SQE
Technical Data
& Accessories
Technical Data
33
SQ/SQE Technical Data
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
34
ELECTRIC
Supply Voltage: 1x200-240V +6%/-10%, 50/60 Hz, PE
1x100-115V +6%/-10%, 50/60 Hz, PE
Operation via Generator: As a minimum, the generator output
must be equal to the motor P1[KW] +10%
Starting Current: The motor starting current is equal to the
highest value stated on the motor nameplate
Starting: Soft-start
Run-up Time: Maximum : 2 seconds
Motor Protection: The motor is protected against:
Dry running, overvoltage, undervoltage,
overload, overtemperature
Power Factor: PF= 1
Service Factor: 0.33-0.50A[Hp]-1.75 at 115V/230V
0.50-0.75A[Hp]-1.4 at 230V
1.0 -1.5C[Hp] -1.15 at 230V
Motor Cable: 3 Wire, 14 AWG XLPE
Motor Liquid: Type SML 2
pH Values: SQ and SQE: 5 to 9
Liquid Temperature: The temperature of the pumped liquid must
not exceed 104°F.
Note: if liquids with a viscosity higher than that of water are to be pumped,
please contact GRUNDFOS
PIPING CONNECTION
Discharge Port: 5SQ/SQE- 1"NPT
10-15SQ/SQE- 1 1/4" NPT
22-30SQ/SQE- 1 1/2" NPT
STORAGE CONDITIONS
Minimum Ambient Temperature: -4°F
Maximum Ambient Temperature: +140°F
Frost Protection: If the pump has to be stored after use, it
must be stored on a frost-free location or it
must be ensured that the motor liquid is
frost-proof. The motor must be stored
without being filled with motor liquid.
OPERATING CONDITIONS
Minimum Ambient Fluid Temperature: 34°F
Maximum Ambient Fluid Temperature: +104°F
APPROXIMATE DIMENSIONS AND WEIGHT
Motor Dimensions (MS 3 & MSE 3):
0.33-0.50A[Hp] 20.9" length x 2.68" diameter
0.50-0.75B[Hp] 20.9" length x 2.68" diameter
1.0-1.5C[Hp] 22.3" length x 2.68" diameter
Motor Weights (MS 3 & MSE 3):
0.33-0.50A[Hp] 6.0 lbs
0.50-0.75B[Hp] 7.1 lbs
1.0-1.5C[Hp] 8.2 lbs
Pump End Dimensions:
Pump Diameter: 2.68"
Pump Diameter, incl. cable guard: 2.91"
Pump End Dimensions(min. and max.):
5SQ/SQE 10.6" to 18.0"
10SQ/SQE 10.6" to 16.9"
15SQ/SQE 10.6" to 16.9"
22SQ/SQE 10.6" to 16.9"
30SQ/SQE 10.6" to 13.7"
Pump End Weights (min. and max.):
All SQ/SQE Models 2.2 lbs to 3.5 lbs
Well Diameter (minimum): 3"
Installation Depth (Maximum): 500 feet, below static water level
SQ/SQE Technical Data
Technical Data
35
Description Product no.
CU300 Status Box 96422776
No contact
Overvoltage
Undervoltage
Dry running
Speed reduction
Overtemperature
Overload
Sensor alarm
On
Off
CU 300
GRUNDFOS
Description Product no.
5-15 SQE 96022968
(Includes CU300, pressure transducer & .5 gpm flow switch)
22-30 SQE 96022971
(Includes CU300, pressure transducer & 1 gpm flow switch)
Constant Pressure Kit
Description Product no.
5-15 SQE .5 GPM 96022967
22-30 SQE 1 GPM 96022970
Flow Switch
Description Product no.
Pressure Transducer 0-90 psi (0-6 bar) 96026030
Pressure Transducer
CU300 Status Box
SQ/SQE Accessories
Description Product no.
3" Sanitary Well Seal 1B5102
3" Well Seal
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
36
SQE - Speed calculation software
SQ/SQE - Flow sleeve
Description Product no.
Flow Sleeve Complete 96037505
Description Product no.
The R100 is used for wireless infrared communication with the CU300 6253333
Description Product no.
Printer for R100, infrared communication 620480
Type: Hewlett Packard, HP 82240B
Paper Roll 620481
Description Version Product no.
External potentiometer with cabinet Grundfos potentiometer, SPP1
for wall mounting. Enclosure class: IP 55 655468
Screened cables, 4-wire cable,
max. length of cable: 100m
Description Product no.
Speed calculation program (Windows95) including:
• PC Tool SQE speed calculation, two diskettes 96426840
• Operating manual
SQ/SQE Accessories
Technical Data
37
Notes
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
38
Notes
Technical Data
39
Notes
SQ/SQE Data
CAPACITY (GPM)
HEAD(FEET)
40
Grundfos Pumps Corporation
Customer Service Centers:
Phone: Fax:
Canada: Mexico:
• 3131 N. Business Park Avenue • Fresno, CA 93727
Allentown, PA • Fresno, CA
(559) 292-8000 • (559) 291-1357
Oakville, Ontario • Apodaca, N.L.
Visit our website at www.us.grundfos.com
ISO 9001
REGISTERED
L-SQ-TL-002 Rev.7/99
PRINTED IN USA

More Related Content

What's hot

Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...
Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...
Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...Seckou Fossar SOUANE
 
université artois BA-EUROCODE-2-partie2.pdf
université artois BA-EUROCODE-2-partie2.pdfuniversité artois BA-EUROCODE-2-partie2.pdf
université artois BA-EUROCODE-2-partie2.pdfHugoLAURENT7
 
Beton katkı kimyasalları
Beton katkı kimyasallarıBeton katkı kimyasalları
Beton katkı kimyasallarıOmer Ercan
 
penelitian implementasi teori Jean Piaget
penelitian implementasi teori Jean Piagetpenelitian implementasi teori Jean Piaget
penelitian implementasi teori Jean PiagetRissa ZH
 
Perkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanak
Perkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanakPerkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanak
Perkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanakFaFai S.
 
HAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERT
HAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERTHAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERT
HAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERTStanleylucas
 
Pendidikan khas di malaysia
Pendidikan khas di malaysiaPendidikan khas di malaysia
Pendidikan khas di malaysiaMaszenah Alan
 
Poem - School Over
Poem - School OverPoem - School Over
Poem - School OverKjx Xuan
 
Calcul des radiers- SampleofChaptertoResearchGate.pdf
Calcul des radiers- SampleofChaptertoResearchGate.pdfCalcul des radiers- SampleofChaptertoResearchGate.pdf
Calcul des radiers- SampleofChaptertoResearchGate.pdfgrandprime1
 
Berfikir secara kreatif
Berfikir secara kreatif Berfikir secara kreatif
Berfikir secara kreatif firo HAR
 
teori perkembangan manusia (kecerdasan pelbagai)
teori perkembangan manusia (kecerdasan pelbagai)teori perkembangan manusia (kecerdasan pelbagai)
teori perkembangan manusia (kecerdasan pelbagai)Yuvarani Subramaniam
 
Everything’s Arranged by Siew Yue Killingley
Everything’s Arranged by Siew Yue KillingleyEverything’s Arranged by Siew Yue Killingley
Everything’s Arranged by Siew Yue KillingleyIllyana Nazri
 
Les étapes de la fabrication du ciment soufiane merabti
Les étapes de la fabrication du ciment  soufiane merabti Les étapes de la fabrication du ciment  soufiane merabti
Les étapes de la fabrication du ciment soufiane merabti soufiane merabti
 
charpante metalique 3 1-introduction
charpante metalique 3 1-introductioncharpante metalique 3 1-introduction
charpante metalique 3 1-introductionmassinissachilla
 
Nota Pengenalan Drama
Nota Pengenalan DramaNota Pengenalan Drama
Nota Pengenalan DramaIsmail Noh
 

What's hot (19)

Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...
Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...
Dimensionnement des pannes et traverses, et pré-Dimensionnement des montants ...
 
Footfall vibration analysis
Footfall vibration analysisFootfall vibration analysis
Footfall vibration analysis
 
université artois BA-EUROCODE-2-partie2.pdf
université artois BA-EUROCODE-2-partie2.pdfuniversité artois BA-EUROCODE-2-partie2.pdf
université artois BA-EUROCODE-2-partie2.pdf
 
Transformasi kurikulum (KSSR)
Transformasi kurikulum (KSSR)Transformasi kurikulum (KSSR)
Transformasi kurikulum (KSSR)
 
Beton katkı kimyasalları
Beton katkı kimyasallarıBeton katkı kimyasalları
Beton katkı kimyasalları
 
penelitian implementasi teori Jean Piaget
penelitian implementasi teori Jean Piagetpenelitian implementasi teori Jean Piaget
penelitian implementasi teori Jean Piaget
 
Perkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanak
Perkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanakPerkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanak
Perkembangan kanak-kanak - EDUP3023 Perkembangan Awal Kanak-kanak
 
Dalles 4 appuis
Dalles 4 appuis Dalles 4 appuis
Dalles 4 appuis
 
HAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERT
HAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERTHAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERT
HAITI: TEMOIGNAGE SHERLSON SANON CONTRE JOSEPH LAMBERT
 
Pendidikan khas di malaysia
Pendidikan khas di malaysiaPendidikan khas di malaysia
Pendidikan khas di malaysia
 
Poem - School Over
Poem - School OverPoem - School Over
Poem - School Over
 
Calcul des radiers- SampleofChaptertoResearchGate.pdf
Calcul des radiers- SampleofChaptertoResearchGate.pdfCalcul des radiers- SampleofChaptertoResearchGate.pdf
Calcul des radiers- SampleofChaptertoResearchGate.pdf
 
Ppt pra-3112
Ppt pra-3112Ppt pra-3112
Ppt pra-3112
 
Berfikir secara kreatif
Berfikir secara kreatif Berfikir secara kreatif
Berfikir secara kreatif
 
teori perkembangan manusia (kecerdasan pelbagai)
teori perkembangan manusia (kecerdasan pelbagai)teori perkembangan manusia (kecerdasan pelbagai)
teori perkembangan manusia (kecerdasan pelbagai)
 
Everything’s Arranged by Siew Yue Killingley
Everything’s Arranged by Siew Yue KillingleyEverything’s Arranged by Siew Yue Killingley
Everything’s Arranged by Siew Yue Killingley
 
Les étapes de la fabrication du ciment soufiane merabti
Les étapes de la fabrication du ciment  soufiane merabti Les étapes de la fabrication du ciment  soufiane merabti
Les étapes de la fabrication du ciment soufiane merabti
 
charpante metalique 3 1-introduction
charpante metalique 3 1-introductioncharpante metalique 3 1-introduction
charpante metalique 3 1-introduction
 
Nota Pengenalan Drama
Nota Pengenalan DramaNota Pengenalan Drama
Nota Pengenalan Drama
 

Similar to Curvas de bombas grundfos

Datasheet de softstarters
Datasheet de softstartersDatasheet de softstarters
Datasheet de softstarterssafetycontrol
 
двигатели MGE Grundfos с IE5
двигатели MGE Grundfos с IE5двигатели MGE Grundfos с IE5
двигатели MGE Grundfos с IE5Arve
 
2 PCCE White_Paper-Rev5
2 PCCE White_Paper-Rev52 PCCE White_Paper-Rev5
2 PCCE White_Paper-Rev5Victor Sauers
 
Ls catalog thiet bi tu dong ss7 e_110530
Ls catalog thiet bi tu dong ss7 e_110530Ls catalog thiet bi tu dong ss7 e_110530
Ls catalog thiet bi tu dong ss7 e_110530Dien Ha The
 
Ls catalog thiet bi tu dong ss7 e_110530_dienhathe.vn
Ls catalog thiet bi tu dong ss7 e_110530_dienhathe.vnLs catalog thiet bi tu dong ss7 e_110530_dienhathe.vn
Ls catalog thiet bi tu dong ss7 e_110530_dienhathe.vnDien Ha The
 
star delta auto starter with forward reverse and motor protection
star delta auto starter with forward reverse and motor protectionstar delta auto starter with forward reverse and motor protection
star delta auto starter with forward reverse and motor protectionBHUPATI PRADHAN
 
Escavadeira hidraulica cat 390 dl
Escavadeira hidraulica cat 390 dlEscavadeira hidraulica cat 390 dl
Escavadeira hidraulica cat 390 dl85283081
 
Teikoku General Brochure
Teikoku General BrochureTeikoku General Brochure
Teikoku General Brochureodang wijaya
 
CS electric Control Panel Product presentation
CS electric Control Panel Product  presentationCS electric Control Panel Product  presentation
CS electric Control Panel Product presentationMahesh Chandra Manav
 
railway workshop jodhpur
railway workshop jodhpurrailway workshop jodhpur
railway workshop jodhpurkalumutha
 
railway workshop jodhpur
railway workshop jodhpur railway workshop jodhpur
railway workshop jodhpur kalumutha
 
Century Motors Bulletin 1505B_Single-ThreePhase_Integral_HP
Century Motors Bulletin 1505B_Single-ThreePhase_Integral_HPCentury Motors Bulletin 1505B_Single-ThreePhase_Integral_HP
Century Motors Bulletin 1505B_Single-ThreePhase_Integral_HPJim Milbaugh
 
Simulation of Automatic Water Level Control System by using Programmable Logi...
Simulation of Automatic Water Level Control System by using Programmable Logi...Simulation of Automatic Water Level Control System by using Programmable Logi...
Simulation of Automatic Water Level Control System by using Programmable Logi...ijtsrd
 
AUTOMATIC COIL WINDING MACHINE
AUTOMATIC COIL WINDING MACHINEAUTOMATIC COIL WINDING MACHINE
AUTOMATIC COIL WINDING MACHINEIRJET Journal
 
INTERNAL GEAR PUMP
INTERNAL GEAR PUMPINTERNAL GEAR PUMP
INTERNAL GEAR PUMPSuchit Moon
 
Catalogo motores neumaticos
Catalogo motores neumaticosCatalogo motores neumaticos
Catalogo motores neumaticosuzbeko123
 
Гидромоторы серий MM-MP-MR-MH M+S hydraulic
Гидромоторы серий MM-MP-MR-MH M+S hydraulicГидромоторы серий MM-MP-MR-MH M+S hydraulic
Гидромоторы серий MM-MP-MR-MH M+S hydraulicArve
 

Similar to Curvas de bombas grundfos (20)

Datasheet de softstarters
Datasheet de softstartersDatasheet de softstarters
Datasheet de softstarters
 
двигатели MGE Grundfos с IE5
двигатели MGE Grundfos с IE5двигатели MGE Grundfos с IE5
двигатели MGE Grundfos с IE5
 
2 PCCE White_Paper-Rev5
2 PCCE White_Paper-Rev52 PCCE White_Paper-Rev5
2 PCCE White_Paper-Rev5
 
Ls catalog thiet bi tu dong ss7 e_110530
Ls catalog thiet bi tu dong ss7 e_110530Ls catalog thiet bi tu dong ss7 e_110530
Ls catalog thiet bi tu dong ss7 e_110530
 
Ls catalog thiet bi tu dong ss7 e_110530_dienhathe.vn
Ls catalog thiet bi tu dong ss7 e_110530_dienhathe.vnLs catalog thiet bi tu dong ss7 e_110530_dienhathe.vn
Ls catalog thiet bi tu dong ss7 e_110530_dienhathe.vn
 
PMSM.pdf
PMSM.pdfPMSM.pdf
PMSM.pdf
 
390 d
390 d390 d
390 d
 
star delta auto starter with forward reverse and motor protection
star delta auto starter with forward reverse and motor protectionstar delta auto starter with forward reverse and motor protection
star delta auto starter with forward reverse and motor protection
 
Escavadeira hidraulica cat 390 dl
Escavadeira hidraulica cat 390 dlEscavadeira hidraulica cat 390 dl
Escavadeira hidraulica cat 390 dl
 
Teikoku General Brochure
Teikoku General BrochureTeikoku General Brochure
Teikoku General Brochure
 
CS electric Control Panel Product presentation
CS electric Control Panel Product  presentationCS electric Control Panel Product  presentation
CS electric Control Panel Product presentation
 
railway workshop jodhpur
railway workshop jodhpurrailway workshop jodhpur
railway workshop jodhpur
 
railway workshop jodhpur
railway workshop jodhpur railway workshop jodhpur
railway workshop jodhpur
 
Century Motors Bulletin 1505B_Single-ThreePhase_Integral_HP
Century Motors Bulletin 1505B_Single-ThreePhase_Integral_HPCentury Motors Bulletin 1505B_Single-ThreePhase_Integral_HP
Century Motors Bulletin 1505B_Single-ThreePhase_Integral_HP
 
MVE brochure US
MVE brochure USMVE brochure US
MVE brochure US
 
Simulation of Automatic Water Level Control System by using Programmable Logi...
Simulation of Automatic Water Level Control System by using Programmable Logi...Simulation of Automatic Water Level Control System by using Programmable Logi...
Simulation of Automatic Water Level Control System by using Programmable Logi...
 
AUTOMATIC COIL WINDING MACHINE
AUTOMATIC COIL WINDING MACHINEAUTOMATIC COIL WINDING MACHINE
AUTOMATIC COIL WINDING MACHINE
 
INTERNAL GEAR PUMP
INTERNAL GEAR PUMPINTERNAL GEAR PUMP
INTERNAL GEAR PUMP
 
Catalogo motores neumaticos
Catalogo motores neumaticosCatalogo motores neumaticos
Catalogo motores neumaticos
 
Гидромоторы серий MM-MP-MR-MH M+S hydraulic
Гидромоторы серий MM-MP-MR-MH M+S hydraulicГидромоторы серий MM-MP-MR-MH M+S hydraulic
Гидромоторы серий MM-MP-MR-MH M+S hydraulic
 

Recently uploaded

Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)Suman Mia
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024Mark Billinghurst
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZTE
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 

Recently uploaded (20)

Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
 
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
ZXCTN 5804 / ZTE PTN / ZTE POTN / ZTE 5804 PTN / ZTE POTN 5804 ( 100/200 GE Z...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 

Curvas de bombas grundfos

  • 3. Technical Data 3 Table of Contents SQ/SQE Features and Benefits ........................................................... pages 4-6 Applications.......................................................................................... pages 7-9 Communications .............................................................................. pages 10-13 Performance Data............................................................................. pages 15-31 Technical Data & Accessories......................................................... pages 32-36
  • 4. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 4 SQ/SQE Submersible Pumps SQ/SQE pumps are suitable for both continuous and intermittent operation for a variety of applications: · Domestic water supply · Small waterworks · Irrigation · Tank applications SQ, SQE pumps offer the following features: · Dry-Run protection · High efficiency pump and motor · Excellent wear resistance, and sand handling capabilities · Protection against up-thrust · Soft-start · Over-voltage and under-voltage protection · Overload protection · Over-temperature protection · High starting torque Additionally, the SQE pumps offer: · Constant pressure control · Variable speed · Electronic control and communication The SQ and SQE pump models incorporate a totally new motor design. With the use of permanent-magnet technol- ogy within the motor, the SQ/SQE pumps deliver un- matched performance. By combining permanent-magnet motors and Grundfos’s own micro frequency converter, we are now able to control and communicate with the pump in ways never before possible. A few of the features that come out this combination are Constant Pressure Control, Soft-Start, and integrated Dry-Run protection. These are just a few of the many features that the SQ/SQE pumps can offer. The SQ pump models are a simple pump that operates at a constant speed much like today’s conventional pumps. The difference between it and todays' pumps is you get all the benefits of an electronically controlled permanent - magnet motor that cannot be accomplished with a con- ventional induction motor. The SQ pumps are available for single phase power. They use a simple 2-wire design making installation easy. The SQE uses the Grundfos “Smart Motor”. Like the SQ model, we still use the high efficiency permanent magnet motor, but we give this motor the ability to communicate. The “Smart Motor” communicates via the CU300 status box through the power leads. It is not necessary to run any additional wires down the well. By being able to communicate with the pump you can have Constant Pressure Control and the ability to change the pump performance while the pump is installed in the well. Like the SQ motor, this is also a 2-wire motor designed for single-phase operation. The CU300 status box also allows you to communicate with the "Smart Motor" with the R100 infrared remote control. The R100 gives you the ability to monitor and setup your pumping system to meet the specific needs of your application. It is also important to note the “Smart Motor" can operate without the CU300, but you will loose some of the functions that are only possible by using the CU300. The CU300 provides full control of the SQE pumps. If the pump stops, the CU300 will illuminate a light on the front panel. If you have an R100 you will be able to trouble shoot the system and recall the last five causes of failure. Pump and Motor Range Pipe Connection Operating Conditions Type key Example 10 SQ E 05 A 160 -NE Nominal flow GPM Type range Electronic control/communication Horsepower Motor designation Head in ft at nominal flow rate Material specification Features and Benefits Product Description Material SQ/SQE Pump 5,10,15,22,30 gpm Stainless steel AISI 304 SQ-MS 3 Motor Single-phase Stainless steel 1/3 - 1.5 Hp AISI 304 SQE-MSE 3 Motor Single-phase Stainless steel "Smart Motor" 1/3 - 1.5 Hp AISI 304 Pump Type Threaded Connection SQ/SQE 5 1" NPT SQ/SQE 10,15 1 1/4" NPT SQ/SQE 22, 30 1 1/2" NPT Flow velocity past motor Max. liquid temperature 0.0 f/s (Free convection) 86 o F (30 o C) Min. 0.5 f/s 104 o F (40 o C)
  • 5. Technical Data 5 Dry-Run Protection The SQ and SQE incorporate integrated Dry-Run protec- tion. When the water level falls below the inlet of the pump the pump will shut off. After a period of time, the pump will then automatically start up again. For the SQ pumps the cut-off level is factory-set. For the SQE pumps you must set this level by using a CU300 and R100. High Motor Efficiency The SQ and SQE motors are based on a permanent magnet rotor which produce high efficiency within a wide load range. The high and flat efficiency curve of the Permanent-Magnet motor allows for a coverage of a wide power range with the same motor, as compared to con- ventional AC motors. For SQE pumps, this means three motors to cover the horsepower range from 1/3 to 1.5Hp. High Pump Efficiency The pump components are made from a 30% glass filled engineered composite. The pumps are designed to deliver at peak efficiency levels. Because of high pump efficiencies, overall power consumption will be reduced. Excellent Wear Resistance The SQ/SQE pump design uses “floating” impellers. Each impeller has its own tungsten carbide/ceramic bearing. This design and the high quality materials make the pump very wear resistant especially in sandy conditions. Amps sec. Soft start DOL 2 Protection against up-thrust During start-up many pumps start in an up-thrust condi- tion. To prevent damage caused by up-thrust a top bearing has been placed in the motor to protect both the pump and the motor against up-thrust. Soft-Start Both the SQ and SQE motors have a soft start because of the integrated electronics. Soft start reduces the starting current and gives the pump a smooth and steady accel- eration. The soft-start will reduce your chance of water hammer, minimizes the risk of wear and prevent overloading of your circuit during start-up. High Starting Torque Because of the permanent-magnet motor the SQ/SQE pumps have excellent starting capabilities. The high locked rotor torque produced by the PM motor provides a starting torque that is 1.5 times greater than conventional pump motors. Even if the voltage is low the PM motor will still maintain a high starting torque. Overvoltage and Undervoltage Protection Overvoltage and undervoltage may occur at anytime especially if you have an unstable voltage supply. The integrated voltage protection of the SQ and SQE motors protects the motors when the voltage falls outside the permissible voltage range. The 230V pump will cut out if voltage falls below 150V or above 280V. The motor will automatically start when the voltage is within the permissible voltage range. It is not necessary to have additional voltage protection. Overload Protection When the pump load rises above the maximum amp level, the motor will automatically compensate and reduce the speed to maintain its maximum amp level. If the speed drops to 65% of the nominal speed, the motor will shut off. Features and Benefits 200 250 300 350 400 450 500 550 600 [W] 45 50 55 60 65 70 [%] Conventional 1ph Conventional 3ph MS 3
  • 6. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 6 0 Q [m‡/h] 0 [m] H 65 % 100 % Overtemperature Protection Permanent-magnet motors emit very little heat because of their high efficiency. The SQ and SQE motors are de- signed with an internal circulation system to effectively cool all the internal motor components. As extra protection, the electronic unit also has a built-in temperature sensor. When the temperature rises too high, the motor will shut off; when the temperature drops, the motor will automatically restart. Reliability The SQ and SQE motors have been designed to with- stand the toughest of applications and provide reliability. Some of those features are: · Tungsten carbide/ceramic bearings · Thrust bearings protecting against down-thrust · Product lifetime equal or greater than conventional AC motors and 4"pumps Variable Speed The SQE “Smart Motor” enables continuous variable speed control within 65% - 100%(7000-10700 rpm) of motor speed. The pump can be set to operate at any duty point in the range between 65% and 100% of the pump's performance curve. Your pump can then be adapted to any specific requirement. The variable speed control requires the CU300 control unit and the R100. To help you decide on the proper speed, we have made available a speed calculation program called “SQE – Speed Calculation”. This program is available as an option. Installation The SQ and SQE may be installed vertically or horizon- tally. Note: The pump must not fall below the horizontal level in relation to the motor. The following features ensure simple installation of the SQ and SQE pumps: · Built-in spring loaded check-valve · Light weight makes it easy to install · Fits in 3” or larger wells For horizontal installation, a flow sleeve is recommended in order to: · Ensure sufficient flow past the motor to provide sufficient cooling · Prevent the unit from being buried in sand or mud Service The modular design of the pump and motor makes it easy to repair and service. The motor lead is also replaceable. Features and Benefits Variable Speed Range of Operation
  • 7. Technical Data 7 SQ is the perfect pump for domestic water supply. The SQ is easy to sell, install and operate. Replacement in Existing Installation SQ and SQE pumps can be installed as replacement of a 4” submersible pump in an existing installation. By replacing an existing 4” pump with an SQ or SQE, you not only get the most advanced pump on the market, but you also have the ability to upgrade your system to a constant pressure system as shown on page 8. Applications SQ with Pressure Switch and Diaphragm Tank
  • 8. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 8 Function and Benefits Constant pressure can be maintained in the system to provide you with “city like” water pressure. A flow switch starts the pump once the tap is opened. A preset pressure is maintained via the pressure sensor and the CU300. When the flow switch detects no flow, the tank is filled with water and the pump stops. If consumption is below 0.8 gpm, the CU300 will start the pump when the pressure is 7 psi below the set-point. The pump will then stop when the pressure is 7 psi above the set-point. When consumption is above 0.8 gpm, the CU300 will control the pump performance to keep the pressure within 3 psi of the set-point. Constant pressure control reduces pressure variations, and allows you to use a tank as small as 2 gal. Without loss of comfort. In installations incorporating filters, pump operation will gradually adjust as the filter becomes plugged. Applications SQE with Constant Pressure Control 1 SQE Pump 2 Drop Pipe 3 Supply 4 Flow Switch 5 Pressure Transducer 6 Relief Valve 7 Diaphragm Tank 8 R100 Remote 9 CU300
  • 9. Technical Data 9 Pumping from One Tank to Another The SQE pump is ideal where there is a need to move water from one tank to another. Applications
  • 10. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 10 CU300 Status Box The CU300 status box is a control and communication unit especially developed for the SQE submersible pumps. The CU300 status box provides: · Easy adjustment to a specific well · Full control of the SQE pumps · Two-way communication with the SQE pumps · Indicator lights on the front to indicate alarms · The ability to start and stop the pump with the push of a button The CU300 communicates with the pump using the power leads. It is not necessary to run any extra cables between the pump and the CU300 status box. The following alarms can be indicated by the CU300: · No contact · Overvoltage · Undervoltage · Dry-Run · Speed reduction · Overtemperature · Overload · Sensor alarm The CU300 incorporates: · External signal input for three sensors · Relay output for external alarm indication · Control according to the signals received, e.g. flow pressure, water level and conductivity The CU300 can communicate with the R100 infrared remote control. R100 Remote control The R100 allows you to monitor the installation by reading current operating parameters, such as: · Power consumption · Energy consumption · Number of operating hours It allows you to change factory settings. A number of settings can be made, such as: · Speed (performance) · Constant pressure control mode · De-watering function · Automatic restart time Communication CU300 9.1 4.5 7.7
  • 11. Technical Data 11 R100 Menu Structure 0. General 2. Status 3. Limits 4. Installation1. Operation 1.1 1.2 1.3 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 3.12 4.92.9 4.10
  • 12. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 12 R100 Menu Structure for the CU300 0. General 1. Operation 1.1 Set-point setting 1.2 Selection of operating mode 1.3 Alarm indication 2. Status The indication of: 2.1 Actual operating mode 2.2 Actual and external set point 2.3 Actual motor temperature 2.4 Actual motor speed 2.5 Actual power input and accumulated motor power consumption 2.6 Accumulated number of operating hours and accumulated number of starts 2.7 Actual values of sensors 1 and 2 respectively 2.8 Actual values of the digital input 2.9 Accumulated flow, and the power used to pump 1 gal. R100 allows you to make a number of settings: 3. Limits The setting of: 3.1 Sensor 1 3.2 Min. and max. stop limit of sensor 1 3.3 Min. and max. warning limit of sensor 1 3.4 Min. and max. alarm limit of sensor 1 3.5 Sensor 2 3.6 Min. and max. stop limit of sensor 2 3.7 Min. and max. warning limit of sensor 2 3.8 Min. and max. alarm limit of sensor 2 3.9 Filling or emptying 3.10 Setting of the function of the digital sensor connected to the digital input 3.11 The setting of the water quantity stop limit and the setting of the sensor to detect water quantity 3.12 The setting of the temperature warning limits of the motor electronics 4. Installation 4.1 Selection of controller 4.2 Setting of external set-point 4.3 Setting of automatic restart time 4.4 Allocation of individual start delays 4.5 Setting of the stop and run times for the de-water ing function. 4.6 Setting of the minimum value of the pump power input 4.7 Activating or deactivating the Dry-Run protection. 4.8 Setting of the maximum motor speed 4.9 Activating or deactivating the on/off-button on the CU 300. 4.10 Allocation of number where more than one CU 300 is installed. Status report All settings and measured values can be transferred to a portable printer via wireless infrared communication and be printed in a status report. R100 Menu Structure
  • 13. Technical Data 13 Examples of R100 displays Menu OPERATION Set-point Setting From the factory, the pump is set to maximum speed, 10,700 rpm. R100 allows you to reduce the pump speed by changing the setpoint. The speed can be set from 7,000 – 10,700 rpm, at 100 rpm intervals. The unit of the set-point is automatically changed accord- ing to the unit of the sensor connection to sensor input no. 1. EXAMPLE: Sensor input no. 1 is connected to a pressure sensor using the unit feet (ft.) and the range 0 – 200. Therefore, the set-point of display 1.1 can be set to between 0 – 200 ft. Menu STATUS The displays appearing in this menu are status displays only. You cannot change settings in this menu. Accumulated Flow In display 2.9, the water quantity (gal.) pumped is shown. The value shown is the accumulated flow registered by the sensor selected in display 3.11. The power used to pump 1 gal. is shown in the display as energy per gal. (kWh/gal.). Accumulated Number of Operating Hours and Number of Starts The value of operating hours and the number of starts are values accumulated from the time of installation and they cannot be reset. Both values are stored in the motor electronics, and are kept even if the CU300 is replaced. The number of operating hours is registered every two minutes of continuous operation. Menu LIMITS The Setting of Sensor 1. Depending on the type of sensor, the following settings can be made: Sensor outputs: (not active), 0-10V, 2-10V, 0-20 mA, 4-20mA. Setting range unit: M3 /h, m, %, gpm, ft. R100
  • 16. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 16 SQ/SQE Data Easy Selection Chart 5SQ/SQE 5 SQ/SQE SELECTION CHARTS FLOW RANGE PUMP OUTLET (Ratings are in GALLONS PER MINUTE-GPM) (1.5 TO 8 GPM) 1" NPT DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET PUMP MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100 0 8 7.5 6.7 5.7 4.4 2.6 0.4 20 6.5 5.5 4.2 2.3 0.1 5SQ/SQE03A-90 1/3 30 5.1 3.6 1.6 40 3.6 1.5 50 1 60 SHUT-OFF PSI: 97 89 78 71 20 11 2 0 8 7.7 7.3 6.7 6.1 5.5 4.7 3.7 2.6 1 20 7.1 6.6 6 5.3 4.5 3.5 2.2 0.6 5SQ/SQE03A-140 1/3 30 6.5 5.9 5.1 4.3 3.3 1.9 40 5.8 5.1 4.1 3.2 1.8 50 4.9 4 3 1.4 60 3.8 2.6 1 SHUT-OFF PSI: 82 74 65 56 48 39 30 22 13 4 0 7.9 7.5 7.1 6.7 6.2 5.6 5.1 4.4 3.6 2.6 1.1 20 7.8 7.4 7 6.5 6.1 5.5 4.9 4.2 3.3 2.3 0.8 5SQ/SQE05A-180 1/2 30 7.3 6.9 6.5 5.9 5.4 4.8 4.1 3.2 2 0.2 40 6.9 6.5 5.9 5.4 4.7 4 3.1 2 0.1 50 6.3 5.8 5.3 4.6 3.8 2.9 1.6 60 5.7 5.1 4.4 3.6 2.6 1.2 SHUT-OFF PSI: 110 102 93 84 76 67 58 50 41 33 24 15 7 0 8 7.7 7.3 6.9 6.5 6.1 5.6 5.1 4.6 4.1 3.4 2.8 0.8 20 8 7.6 7.1 6.8 6.3 5.9 5.4 5 4.5 3.9 3.3 2.6 1.8 0.6 5SQ/SQE05B-230 1/2 30 7.9 7.5 7.1 6.7 6.3 5.9 5.4 4.9 4.4 3.8 3.1 2.4 1.5 40 7.5 7.1 6.7 6.3 5.8 5.4 4.9 4.3 3.7 3.1 2.3 1.4 50 7 6.6 6.2 5.8 5.3 4.8 4.2 3.6 2.9 2.2 1.2 60 6.5 6.1 5.6 5.1 4.6 4.1 3.4 2.8 2 0.9 SHUT-OFF PSI: 143 134 126 117 108 100 91 82 74 65 56 48 39 30 22 4 0 8 7.8 7.5 7.2 6.8 6.5 6.1 5.8 5.3 4.9 4.4 3.4 1.2 20 8 7.7 7.4 7.1 6.7 6.4 6 5.6 5.2 4.8 4.3 3.8 3.2 1.8 5SQ/SQE05B-270 1/2 30 8 7.7 7.3 7 6.7 6.3 5.9 5.5 5.1 4.7 4.2 3.7 3.1 2.4 0.8 40 8 7.7 7.3 7 6.7 6.3 5.9 5.5 5.1 4.7 4.2 3.7 3.1 2.4 1.6 50 7.6 7.3 6.9 6.6 6.2 5.9 5.2 5 4.6 4.1 3.5 3 2.2 1.5 0.6 60 7.2 6.9 6.5 6.1 5.7 5.3 4.9 4.4 3.9 3.4 2.7 2.1 1.2 0.2 SHUT-OFF PSI: 175 167 158 149 141 132 123 115 106 97 89 80 71 63 54 37 11 0 7.9 7.6 7.3 7 6.7 6.4 6.1 5.7 5.4 4.6 3.4 1.6 20 7.8 7.5 7.2 6.9 6.6 6.3 6 5.6 5.3 4.9 4.5 3.9 2.1 5SQ/SQE07B-320 3/4 30 8 7.7 7.5 7.1 6.9 6.5 6.2 5.9 5.5 5.2 4.8 4.4 4 3.1 1.2 40 8 7.7 7.5 7.1 6.9 6.5 6.2 5.9 5.5 5.2 4.8 4.4 4 3.5 2.5 0.2 50 7.9 7.6 7.4 7.1 6.8 6.5 6.1 5.8 5.5 5.1 4.7 4.3 3.9 3.5 3 1.9 60 7.6 7.3 7 6.7 6.4 6 5.7 5.4 5 4.6 4.2 3.8 3.3 2.8 2.2 0.8 SHUT-OFF PSI: 249 240 232 223 214 206 197 188 180 171 162 154 145 136 128 110 84 58 0 8 7.7 7.4 7.2 6.9 6.6 6.3 6 5.4 4.4 3.3 1.9 20 7.9 7.6 7.3 7.1 6.8 6.5 6.2 5.9 5.6 5.3 4.7 3.6 2.3 5SQ/SQE10C-360 1 30 8 7.8 7.6 7.3 7 6.7 6.5 6.2 5.9 5.6 5.3 4.9 4.3 3.1 1.6 40 8 7.8 7.5 7.3 7 6.7 6.5 6.1 5.9 5.6 5.3 4.9 4.6 3.9 2.6 0.8 50 0.8 7.8 7.5 7.2 7 6.7 6.4 6.1 5.8 5.5 5.2 4.9 4.5 4.2 3.3 2 60 8 7.7 7.4 7.2 6.9 6.6 6.3 6 5.7 5.4 5.1 4.8 4.4 4.1 3.7 2.9 1.2 SHUT-OFF PSI: 234 227 219 210 201 193 184 175 167 158 149 141 132 123 115 97 71 46 20 0 7.9 7.6 7.4 7.1 6.8 6.5 6 5.1 4.2 3.2 1.4 20 7.8 7.6 7.3 7 6.7 6.5 6.2 5.9 5.3 3.6 3.4 2.3 5SQ/SQE10C-410 1 30 8 7.8 7.5 7.3 7 6.7 6.4 6.1 5.9 5.6 5 4.1 3 1.7 40 8 7.8 7.5 7.3 7 6.7 6.4 6.1 5.8 5.6 5.3 4.7 3.7 2.6 1.1 50 8 7.7 7.4 7.2 6.9 6.6 6.3 6.1 5.8 5.5 5.2 4.9 4.3 3.3 2.1 60 7.9 7.6 7.4 7.1 6.8 6.5 6.3 6 5.7 5.4 5.1 4.8 4.5 3.9 2.8 1.4 SHUT-OFF PSI: 249 240 232 223 214 206 197 188 180 171 162 154 145 128 102 76 50 15 0 7.9 7.6 7.4 7.1 6.6 5.8 5 4.1 2.9 20 7.9 7.6 7.3 7 6.7 6.5 6 5.1 4.3 3.4 2 5SQ/SQE10C-450 1 30 8 7.8 7.5 7.2 6.9 6.7 6.4 6.1 5.6 4.8 4 3.1 1.5 40 8 7.8 7.5 7.2 7 6.7 6.4 6.2 5.9 5.4 4.5 3.7 2.7 0.8 50 8 7.7 7.5 7.2 6.9 6.6 6.4 6.1 5.9 5.6 5 4.2 3.3 2.3 60 7.9 7.6 7.4 7.1 6.8 6.6 6.3 6 5.8 5.5 5.2 4.7 3.8 7.9 1.7 SHUT-OFF PSI: 264 255 247 238 229 221 212 203 194 186 177 160 134 108 82 48
  • 17. Technical Data 17 SQ/SQE Data Easy Selection Chart 10SQ/SQE 10 SQ/SQE SELECTION CHARTS FLOW RANGE PUMP OUTLET (Ratings are in GALLONS PER MINUTE-GPM) (3 TO 15 GPM) 1 1/4" NPT DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET PUMP MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100 0 14.8 13.5 12.5 11.0 9.0 6.0 20 13.5 12.0 10.5 8.5 5.0 10SQ/SQE03A-110 1/3 30 11.8 10.0 8.0 40 10.0 8.0 50 60 SHUT-OFF PSI: 56 48 35 30 17 13 4 0 14.8 14.0 13.0 12.0 11.0 10.0 8.0 5.0 20 14.6 13.8 13.0 12.0 11.0 9.5 7.5 4.0 10SQ/SQE05A-160 1/2 30 13.5 12.8 11.8 10.5 9.0 7.0 2.0 40 12.8 11.8 10.5 9.0 7.0 2.0 50 11.5 10.2 8.5 6.0 60 10.0 8.0 5.0 SHUT-OFF PSI: 84 76 67 58 50 41 32 24 15 6 0 14.8 14.0 13.5 12.8 12.0 11.0 10.0 9.0 7.0 5.0 20 14.5 14.0 13.3 12.5 11.8 10.8 9.8 8.5 6.5 4.0 10SQ/SQE05B-200 1/2 30 14.5 13.8 11.8 12.5 11.5 10.5 9.5 8.0 6.0 3.0 40 13.8 13.0 12.5 11.5 10.5 9.5 8.0 6.0 3.0 50 13.0 12.0 11.5 10.5 9.0 7.5 5.5 1.5 60 12.0 11.0 10.0 9.0 7.0 5.0 SHUT-OFF PSI: 113 104 95 87 78 69 61 52 43 35 26 17 7 0 14.6 14.0 13.5 13.0 12.4 11.5 11.0 10.0 9.0 8.0 6.5 2.5 20 15.0 14.5 14.0 13.5 12.8 12.2 11.5 10.8 9.8 8.8 7.8 6.4 4.5 2.0 10SQ/SQE07B-240 3/4 30 15.0 14.3 13.8 13.3 12.8 12.0 11.3 10.5 9.5 8.5 7.5 6.0 4.0 40 14.5 13.8 13.3 12.8 12.0 11.3 10.5 9.5 8.5 7.5 6.0 4.0 50 13.8 13.0 12.5 11.8 11.0 10.3 7.5 8.3 7.0 5.5 3.5 60 13.0 12.4 11.7 11.0 10.0 9.0 8.0 6.7 5.0 2.5 SHUT-OFF PSI: 143 134 126 117 108 100 91 82 74 65 56 48 39 30 22 4 0 14.7 14.3 13.8 13.3 12.8 12.3 11.8 11.0 10.5 9.5 7.7 3.0 20 15.0 14.5 14.2 13.7 13.2 12.8 12.3 11.5 10.8 10.5 9.5 8.5 7.5 4.5 10SQ/SQE10C-290 1 30 15.0 14.5 14.0 13.7 13.2 12.7 12.0 11.5 10.8 10.0 9.3 8.3 7.2 5.8 1.5 40 15.0 14.5 14.0 13.7 13.2 12.5 12.0 11.5 10.8 10.0 9.3 8.3 7.3 5.8 4.0 50 15.0 14.5 14.0 13.0 12.5 12.0 11.2 10.5 9.8 9.0 8.0 7.0 5.5 3.5 1.0 60 13.8 13.3 12.8 12.3 11.8 11.0 10.5 9.6 8.8 7.7 6.5 5.0 3.0 SHUT-OFF PSI: 173 165 156 147 139 130 121 113 104 95 87 78 69 61 52 35 7 0 14.7 14.4 14.0 13.5 13.0 12.7 12.2 11.6 11.0 9.8 7.2 3.0 20 15.0 14.7 14.3 13.8 13.5 13.0 12.5 12.0 11.5 10.8 10.3 9.5 8.0 4.5 10SQ/SQE10C-330 1 30 15.0 14.5 14.2 13.8 13.3 12.8 12.5 11.8 11.3 10.8 10.2 9.5 8.8 6.8 2.2 40 15.0 14.6 14.2 13.8 13.4 12.8 12.4 12.0 11.4 10.8 10.2 9.5 8.7 7.8 5.5 50 14.8 14.5 14.0 13.7 13.2 12.7 12.2 11.7 11.2 10.5 10.0 9.3 8.5 7.5 6.6 3.5 60 14.4 14.0 13.5 13.0 12.6 12.2 11.5 11.0 10.5 9.7 9.0 8.2 7.3 6.1 4.8 1.2 SHUT-OFF PSI: 203 195 186 177 169 160 152 143 134 126 117 108 100 91 82 65 39 13 0 15.0 14.7 14.3 14.0 13.7 13.3 12.8 12.5 12.0 11.0 9.3 7.0 3.5 20 15.0 14.6 14.3 13.8 13.5 13.3 12.8 12.3 12.0 11.5 11.0 9.8 7.8 4.7 10SQ/SQE15C-380 1 1/2 30 15.0 14.5 14.3 13.8 13.5 13.3 12.8 12.3 11.8 11.3 10.8 10.3 9.0 6.5 3.0 40 14.8 14.5 14.3 13.8 13.5 13.0 12.7 12.3 11.8 11.3 10.8 10.3 9.8 8.3 5.5 1.0 50 14.8 14.5 14.1 13.7 13.3 13.0 12.5 12.2 11.7 11.2 10.7 10.2 9.5 8.8 7.2 4.0 60 14.7 14.4 14.0 13.7 13.3 13.0 12.5 12.0 11.5 11.0 10.5 10.0 9.4 8.7 8.0 6.0 2.0 SHUT-OFF PSI: 234 225 216 208 199 191 182 173 165 156 147 138 130 121 113 95 69 43 30
  • 18. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 18 15SQ/SQE Easy Selection Chart SQ/SQE Data 15 SQ/SQE SELECTION CHARTS FLOW RANGE PUMP OUTLET (Ratings are in GALLONS PER MINUTE-GPM) (4 TO 20 GPM) 1 1/4" NPT DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET PUMP MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100 0 19.5 16.5 13 8.5 20 15.5 12 7 15SQ/SQE03A-70 1/3 30 11 5 40 5 50 60 SHUT-OFF PSI: 41 32 24 15 7 0 19.5 17.5 16 13.5 11 7.5 20 19 17.5 15.5 13 10.5 6.5 15SQ/SQE05A-110 1/2 30 17 14.5 12.5 9.5 40 14.5 12.5 9.5 50 11.5 8.5 60 7.5 SHUT-OFF PSI: 65 56 48 39 30 22 13 4 0 19 18 17 15.5 14 12 10 7 20 19 18 16.5 15 13.5 11.5 8.5 6 15SQ/SQE05B-150 1/2 30 19 18 16.5 15 13 11 8.5 4.5 40 17.5 16.5 15 13 11 8.5 4.5 50 16.5 14.5 12.5 10.5 7.5 3 60 14 12 10 7 SHUT-OFF PSI: 95 87 78 69 61 52 43 35 26 17 7 0 19.5 18.5 17.5 16.5 15.5 14 12.5 11 9 6.5 20 20 19 18 17 16.5 15 13.5 12.5 10.5 8.5 5.5 15SQ/SQE07B-180 3/4 30 20 19 18 17 16 14.5 13.5 12 10 8 40 19 18 17 16 14.5 13.5 12 10 8 50 17.5 17 15.5 14.5 13 11.5 9.5 7 60 16.5 15.5 14 12.5 11 9 6.5 SHUT-OFF PSI: 117 108 100 91 82 74 65 56 48 39 30 22 15 4 0 19.5 18.5 17.5 17 16 15 14 13 11.5 10 6 20 20 19 18.5 17.5 16.5 15.5 14.5 13.5 12.5 11 9.5 8 5.5 15SQ/SQE10C-220 1 30 20 19 18.5 17.5 16.5 15.5 14.5 13.5 12.5 11 9.5 7.5 4 40 20 19 18.5 17.5 16.5 15.5 14.5 13.5 12.5 11 9.5 7.5 4 50 19 18 17 16 15 14 13 12 10.5 9 6.5 60 18 17 16 15 14 13 11.5 10 8.5 6 SHUT-OFF PSI: 145 136 128 119 110 102 93 84 76 67 58 50 41 32 24 6 0 20 19.5 18 17.5 16.5 15.5 15 14 13 11 5.5 20 20 19.5 18.5 18 17 16.5 15.5 15 14 13 11.5 10.5 6.5 15SQ/SQE10C-250 1 30 19.5 19 18.5 18 17 16 15.5 14.5 13.5 12.5 11.5 10.5 9 4 40 20 19 18.5 18 17 16.5 15.5 14.5 13.5 12.5 11.5 10.5 9 7 50 19.5 19 18.5 17.5 17 16 15 14.5 13.5 12.5 11 10 8.5 6.5 60 19 18 17.5 17 16 15 14 13 12 11 9.5 8 6 SHUT-OFF PSI: 171 162 154 145 136 128 119 110 102 93 84 76 67 58 50 32 6 0 20 19.5 18.5 18 17.5 17 16.5 15.5 15 13.5 10.5 5.5 20 20 19 18.5 18 17.5 17 16 15.5 14.5 14 13 11 7 15SQ/SQE15C-290 1 1/2 30 19.5 19 18.5 18 17.5 16.5 16 15.5 14.5 13.5 13 12 8.5 40 19.5 19 18.5 18 17.5 16.5 16 15.5 14.5 14 13 12 11 8.5 50 20 19.5 19 18.5 17.5 17 16.5 16 15 14.5 13.5 12.5 11.5 10.5 9.5 6 60 19.5 18.5 18 17.5 17 16.5 15.5 15 14 13.5 12.5 11.5 10.5 9 7.5 SHUT-OFF PSI: 197 188 180 171 162 154 145 136 128 119 110 102 93 84 76 58 32 6
  • 19. Technical Data 19 SQ/SQE Data Easy Selection Chart 22SQ/SQE 22 SQ/SQE SELECTION CHARTS FLOW RANGE PUMP OUTLET (Ratings are in GALLONS PER MINUTE-GPM) (7 TO 33 GPM) 1 1/2" NPT DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET PUMP MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100 0 31.5 23 20 22SQ/SQE03A-40 1/3 30 40 50 60 SHUT-OFF PSI: 17 7 0 31.5 27.5 22.5 19.5 20 26.5 21 11 22SQ/SQE05A-80 1/2 30 19.5 6.5 40 6.5 50 60 SHUT-OFF PSI: 41 32 24 15 7 0 33.0 31.0 28.5 25.5 22 17 7 20 30.5 28 21 15 3 22SQ/SQE05B-120 1/2 30 27 24 20 13 40 24 20 13 50 18.5 10 60 17 SHUT-OFF PSI: 65 56 48 39 30 22 13 4 0 32 30.5 28.5 26.5 24 21 17.5 12 3 20 32 31.5 28 26 23.5 20.5 16.5 10.5 22SQ/SQE07B-160 3/4 30 29.5 27.5 25.5 22.5 19.5 15 8.5 40 27.5 25.5 22.5 19.5 15.0 8.5 50 24.5 22 18.5 14 6 60 21 17.5 12 3 SHUT-OFF PSI: 89 80 71 63 54 45 37 28 19 11 2 0 33 31.5 30.5 29 27.5 25.5 23.5 21 18 14.5 8 20 32.5 31.5 30 28.5 27 25 23 20.5 17.5 13 4 22SQ/SQE10C-190 1 30 31 29.5 28 26.5 24.5 22 20 16.5 12 40 29.5 28 26.5 24.5 22 20 16.5 12 50 27.5 26 24 21.5 19 15.5 1 60 25.5 23.5 21 18 14 8 SHUT-OFF PSI: 107 99 90 81 73 64 55 47 38 29 21 12 4 0 32.5 31.5 30 29 27.5 26 24.5 23 21 18.5 15.5 11.5 20 32.5 31 30 28.5 27.5 25.5 24 22.5 20.5 17.5 14.5 10 22SQ/SQE15C-220 1 1/2 30 32 31 29.5 28.5 27 25.5 23.5 22 19.5 17 14 9 40 31 29.5 28.5 27 25.5 23.5 22.0 19.5 17 14 9 50 29.5 28 26.5 25.0 23.5 21.5 19.0 16.5 12.5 6.5 60 27.5 26.0 24.5 23.0 21.0 18.5 15.5 11.5 SHUT-OFF PSI: 130 121 113 104 95 87 78 69 61 52 43 35 26 17 9
  • 20. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 20 30SQ/SQE Easy Selection Chart SQ/SQE Data 30 SQ/SQE SELECTION CHARTS FLOW RANGE PUMP OUTLET (Ratings are in GALLONS PER MINUTE-GPM) (8 TO 42 GPM) 1 1/2 " NPT DEPTH TO PUMPING WATER LEVEL (LIFT) IN FEET PUMP MODEL HP PSI 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 340 400 460 520 600 700 800 900 1000 1100 0 40.0 30.5 11.0 20 30SQ/SQE05A-40 1/2 30 40 50 60 SHUT-OFF PSI: 20 11 2 0 41 36.5 31 23 9 20 35.5 29 20 4 30SQ/SQE05B-90 1/2 30 27.5 17 40 17 50 60 SHUT-OFF PSI: 48 39 30 22 13 4 0 41.5 38.5 35.5 31.5 27.0 21.0 11.0 20 40.5 37.5 34.5 30.5 25.5 19.0 8.0 30SQ/SQE10C-130 1 30 37.0 33.5 29.5 24.0 17.0 4.0 40 33.5 29.5 24.0 17.0 4.0 50 28.5 22.5 14.0 60 21.0 11.0 SHUT-OFF PSI: 76 67 58 50 41 32 24 15 7 0 41.5 39.5 37 35 32 28.5 24.5 19 11.5 20 41 39 36.5 34 31 27.5 23.5 17.5 9.5 30SQ/SQE15C-170 1 1/2 30 40.5 38.5 36 33 30 26.5 22 16 6 40 38.5 36 33 30 26.5 22 16 6 50 35.5 32.5 29.5 25.5 20.5 14 3 60 32 28.5 24.5 19 11.5 SHUT-OFF PSI: 104 95 87 78 69 61 52 43 35 26 17 9
  • 22. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 22 0 1 2 3 4 5 6 7 8 0 100 200 300 400 500 600 700 800 5 GPMModels 5 SQ/SQE FLOW RANGE: 1.5 - 8 GPM OUTLET SIZE: 1" NPT NOMINAL DIA. 3" 5SQ/SQE03A-90 5SQ/SQE05A-180 5SQ/SQE05B-230 5SQ/SQE05B-270 5SQ/SQE07B-320 5SQ/SQE10C-360 5SQ/SQE10C-410 5SQ/SQE10C-450 5SQ/SQE03A-140 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
  • 23. Technical Data 23 5 GPM Models 5 SQ/SQE DIMENSIONS AND WEIGHTS NOTES: All models suitable for use in 3" wells, unless otherwise noted. Weights include pump end with motor in lbs. MATERIALS OF CONSTRUCTION NOTES: Specifications subject to change without notice. COMPONENT SPLINED SHAFT Valve Casing Polyamide Discharge Chamber 304 Stainless Steel Valve Guide Polyamide Valve Spring 316LN Stainless Steel Valve Cone Polyamide Valve Seat NBR Rubber O-ring NBR Rubber Lock ring 310 Stainless Steel Top Bearing NBR Rubber Top Chamber Polyamide Guide Vanes Polyamide Impeller Polyamide w/tungsten carbide bearings Bottom Chamber Polyamide Neck Ring Polyamide Bearing Ceramic Suction Interconnector Polyamide Ring 304 Stainless Steel Pump Sleeve 304 Stainless Steel Cone for pressure equalization Polyamide Spacer Polyamide Sand Trap 316 Stainless Steel Shaft w/coupling 304 Stainless Steel Cable Guard 304 Stainless Steel Fig. A 1" NPT MOTOR DISCH. DIMENSIONS IN INCHES APPROX. MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT. 5SQ/SQE03A-90 A 1/3 A 3" 1" NPT 30.4 19.8 10.6 2.6 2.9 12 5SQ/SQE03A-140 A 1/3 A 3" 1" NPT 30.4 19.8 10.6 2.6 2.9 12 5SQ/SQE05A-180 A 1/2 A 3" 1" NPT 31.5 19.8 11.6 2.6 2.9 12 5SQ/SQE05B-230 A 1/2 B 3" 1" NPT 33.6 19.8 13.7 2.6 2.9 13 5SQ/SQE05B-270 A 1/2 B 3" 1" NPT 33.6 19.8 13.7 2.6 2.9 13 5SQ/SQE07B-320 A 3/4 B 3" 1" NPT 34.6 19.8 14.8 2.6 2.9 13 5SQ/SQE10C-360 A 1 C 3" 1" NPT 38.2 21.3 16.9 2.6 2.9 16 5SQ/SQE10C-410 A 1 C 3" 1" NPT 38.2 21.3 16.9 2.6 2.9 16 5SQ/SQE10C-450 A 1 C 3" 1" NPT 39.3 21.3 18.0 2.6 2.9 16
  • 24. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 24 0 2 4 6 8 10 12 14 0 100 200 300 400 500 600 10 GPM SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Models 10 SQ/SQE FLOW RANGE: 3 - 15 GPM OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3" 10SQ/SQE03A-110 10SQ/SQE05A-160 10SQ/SQE05B-200 10SQ/SQE07B-240 10SQ/SQE10C-290 10SQ/SQE10C-330 10SQ/SQE15C-380 PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
  • 25. Technical Data 25 Fig. A 10 GPM Models 10 SQ-SQE DIMENSIONS AND WEIGHTS NOTES: All models suitable for use in 3" wells, unless otherwise noted. Weights include pump end with motor in lbs. MATERIALS OF CONSTRUCTION NOTES: Specifications subject to change without notice. 1 1/4" NPT COMPONENT SPLINED SHAFT Valve Casing Polyamide Discharge Chamber 304 Stainless Steel Valve Guide Polyamide Valve Spring 316LN Stainless Steel Valve Cone Polyamide Valve Seat NBR Rubber O-ring NBR Rubber Lock ring 310 Stainless Steel Top Bearing NBR Rubber Top Chamber Polyamide Guide Vanes Polyamide Impeller Polyamide w/tungsten carbide bearings Bottom Chamber Polyamide Neck Ring Polyamide Bearing Ceramic Suction Interconnector Polyamide Ring 304 Stainless Steel Pump Sleeve 304 Stainless Steel Cone for pressure equalization Polyamide Spacer Polyamide Sand Trap 316 Stainless Steel Shaft w/coupling 304 Stainless Steel Cable Guard 304 Stainless Steel MOTOR DISCH. DIMENSIONS IN INCHES APPROX. MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT. 10SQ/SQE03A-110 A 1/3 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12 10SQ/SQE05A-160 A 1/2 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12 10SQ/SQE05B-200 A 1/2 B 3" 1 1/4" NPT 31.5 19.8 11.6 2.6 2.9 13 10SQ/SQE07B-240 A 3/4 B 3" 1 1/4" NPT 33.6 19.8 13.7 2.6 2.9 13 10SQ/SQE10C-290 A 1 C 3" 1 1/4" NPT 35.0 21.3 13.7 2.6 2.9 16 10SQ/SQE10C-330 A 1 C 3" 1 1/4" NPT 36.1 21.3 14.8 2.6 2.9 16 10SQ/SQE15C-380 A 1 1/2 C 3" 1 1/4" NPT 38.2 21.3 16.9 2.6 2.9 16
  • 26. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 26 0 2 4 6 8 10 12 14 16 18 20 0 100 200 300 400 500 15 GPM SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Models 15 SQ/SQE FLOW RANGE: 4 - 20 GPM OUTLET SIZE: 1 1/4" NPT NOMINAL DIA. 3" 15SQ/SQE03A-70 15SQ/SQE05A-110 15SQ/SQE05B-150 15SQ/SQE07B-180 15SQ/SQE10C-220 15SQ/SQE10C-250 15SQ/SQE15C-290 PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
  • 27. Technical Data 27 NOTES: All models suitable for use in 3" wells, unless otherwise noted. Weights include pump end with motor in lbs. Fig. A 15 GPM Models 15 SQ/SQE DIMENSIONS AND WEIGHTS MATERIALS OF CONSTRUCTION NOTES: Specifications subject to change without notice. 1 1/4" NPT COMPONENT SPLINED SHAFT Valve Casing Polyamide Discharge Chamber 304 Stainless Steel Valve Guide Polyamide Valve Spring 316LN Stainless Steel Valve Cone Polyamide Valve Seat NBR Rubber O-ring NBR Rubber Lock ring 310 Stainless Steel Top Bearing NBR Rubber Top Chamber Polyamide Guide Vanes Polyamide Impeller Polyamide w/tungsten carbide bearings Bottom Chamber Polyamide Neck Ring Polyamide Bearing Ceramic Suction Interconnector Polyamide Ring 304 Stainless Steel Pump Sleeve 304 Stainless Steel Cone for pressure equalization Polyamide Spacer Polyamide Sand Trap 316 Stainless Steel Shaft w/coupling 304 Stainless Steel Cable Guard 304 Stainless Steel MOTOR DISCH. DIMENSIONS IN INCHES APPROX. MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT. 15SQ/SQE03A-70 A 1/3 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12 15SQ/SQE05A-110 A 1/2 A 3" 1 1/4" NPT 30.4 19.8 10.6 2.6 2.9 12 15SQ/SQE05B-150 A 1/2 B 3" 1 1/4" NPT 31.5 19.8 11.6 2.6 2.9 13 15SQ/SQE07B-180 A 3/4 B 3" 1 1/4" NPT 33.6 19.8 13.7 2.6 2.9 13 15SQ/SQE10C-220 A 1 C 3" 1 1/4" NPT 35.0 21.3 13.7 2.6 2.9 16 15SQ/SQE10C-250 A 1 C 3" 1 1/4" NPT 36.1 21.3 14.8 2.6 2.9 16 15SQ/SQE15C-290 A 1 1/2 C 3" 1 1/4" NPT 38.2 21.3 16.9 2.6 2.9 16
  • 28. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 28 0 5 10 15 20 25 30 0 50 100 150 200 250 300 350 22 GPM SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Models 22 SQ/SQE FLOW RANGE: 7 - 33 GPM OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3" 22SQ/SQE03A-40 22SQ/SQE05A-80 22SQ/SQE05B-120 22SQ/SQE07B-160 22SQ/SQE10C-190 22SQ/SQE15C-220 PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
  • 29. Technical Data 29 NOTES: All models suitable for use in 3" wells, unless otherwise noted. Weights include pump end with motor in lbs. Fig. A 22 GPM Models 22 SQ/SQE DIMENSIONS AND WEIGHTS MATERIALS OF CONSTRUCTION NOTES: Specifications subject to change without notice. 1 1/2" NPT MOTOR DISCH. DIMENSIONS IN INCHES APPROX. MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT. 22SQ/SQE03A-40 A 1/3 A 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 12 22SQ/SQE05A-80 A 1/2 A 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 12 22SQ/SQE05B-120 A 1/2 B 3" 1 1/2" NPT 31.5 19.8 11.6 2.6 2.9 13 22SQ/SQE07B-160 A 3/4 B 3" 1 1/2" NPT 33.6 19.8 13.7 2.6 2.9 13 22SQ/SQE10C-190 A 1 C 3" 1 1/2" NPT 38.2 21.3 16.9 2.6 2.9 16 22SQ/SQE15C-220 A 1 1/2 C 3" 1 1/2" NPT 38.2 21.3 16.9 2.6 2.9 16 COMPONENT SPLINED SHAFT Valve Casing Polyamide Discharge Chamber 304 Stainless Steel Valve Guide Polyamide Valve Spring 316LN Stainless Steel Valve Cone Polyamide Valve Seat NBR Rubber O-ring NBR Rubber Lock ring 310 Stainless Steel Top Bearing NBR Rubber Top Chamber Polyamide Guide Vanes Polyamide Impeller Polyamide w/tungsten carbide bearings Bottom Chamber Polyamide Neck Ring Polyamide Bearing Ceramic Suction Interconnector Polyamide Ring 304 Stainless Steel Pump Sleeve 304 Stainless Steel Cone for pressure equalization Polyamide Spacer Polyamide Sand Trap 316 Stainless Steel Shaft w/coupling 304 Stainless Steel Cable Guard 304 Stainless Steel
  • 30. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 30 0 5 10 15 20 25 30 35 40 0 50 100 150 200 250 300 30 GPM SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. Models 30 SQ/SQE FLOW RANGE: 8 - 42 GPM OUTLET SIZE: 1 1/2" NPT NOMINAL DIA. 3" 30SQ/SQE05A-40 30SQ/SQE05B-90 30SQ/SQE10C-130 30SQ/SQE15C-170 PERFORMANCE CONFORMS TO ISO 2548 ANNEX B.
  • 31. Technical Data 31 NOTES: All models suitable for use in 3" wells, unless otherwise noted. Weights include pump end with motor in lbs. Fig. A 30 GPM Models SQ-SQE DIMENSIONS AND WEIGHTS MATERIALS OF CONSTRUCTION NOTES: Specifications subject to change without notice. 1 1/2" NPT COMPONENT SPLINED SHAFT Valve Casing Polyamide Discharge Chamber 304 Stainless Steel Valve Guide Polyamide Valve Spring 316LN Stainless Steel Valve Cone Polyamide Valve Seat NBR Rubber O-ring NBR Rubber Lock ring 310 Stainless Steel Top Bearing NBR Rubber Top Chamber Polyamide Guide Vanes Polyamide Impeller Polyamide w/tungsten carbide bearings Bottom Chamber Polyamide Neck Ring Polyamide Bearing Ceramic Suction Interconnector Polyamide Ring 304 Stainless Steel Pump Sleeve 304 Stainless Steel Cone for pressure equalization Polyamide Spacer Polyamide Sand Trap 316 Stainless Steel Shaft w/coupling 304 Stainless Steel Cable Guard 304 Stainless Steel MOTOR DISCH. DIMENSIONS IN INCHES APPROX. MODEL NO. FIG. HP SIZE SIZE A B C D E SHIP WT. 30SQ/SQE05A-40 A 1/2 A 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 12 30SQ/SQE05B-90 A 1/2 B 3" 1 1/2" NPT 30.4 19.8 10.6 2.6 2.9 13 30SQ/SQE10C-130 A 1 C 3" 1 1/2" NPT 35.0 21.3 13.7 2.6 2.9 13 30SQ/SQE15C-170 A 1 1/2 C 3" 1 1/2" NPT 35.0 21.3 13.7 2.6 2.9 16
  • 32. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 32 Grundfos SQ/SQE Technical Data & Accessories
  • 34. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 34 ELECTRIC Supply Voltage: 1x200-240V +6%/-10%, 50/60 Hz, PE 1x100-115V +6%/-10%, 50/60 Hz, PE Operation via Generator: As a minimum, the generator output must be equal to the motor P1[KW] +10% Starting Current: The motor starting current is equal to the highest value stated on the motor nameplate Starting: Soft-start Run-up Time: Maximum : 2 seconds Motor Protection: The motor is protected against: Dry running, overvoltage, undervoltage, overload, overtemperature Power Factor: PF= 1 Service Factor: 0.33-0.50A[Hp]-1.75 at 115V/230V 0.50-0.75A[Hp]-1.4 at 230V 1.0 -1.5C[Hp] -1.15 at 230V Motor Cable: 3 Wire, 14 AWG XLPE Motor Liquid: Type SML 2 pH Values: SQ and SQE: 5 to 9 Liquid Temperature: The temperature of the pumped liquid must not exceed 104°F. Note: if liquids with a viscosity higher than that of water are to be pumped, please contact GRUNDFOS PIPING CONNECTION Discharge Port: 5SQ/SQE- 1"NPT 10-15SQ/SQE- 1 1/4" NPT 22-30SQ/SQE- 1 1/2" NPT STORAGE CONDITIONS Minimum Ambient Temperature: -4°F Maximum Ambient Temperature: +140°F Frost Protection: If the pump has to be stored after use, it must be stored on a frost-free location or it must be ensured that the motor liquid is frost-proof. The motor must be stored without being filled with motor liquid. OPERATING CONDITIONS Minimum Ambient Fluid Temperature: 34°F Maximum Ambient Fluid Temperature: +104°F APPROXIMATE DIMENSIONS AND WEIGHT Motor Dimensions (MS 3 & MSE 3): 0.33-0.50A[Hp] 20.9" length x 2.68" diameter 0.50-0.75B[Hp] 20.9" length x 2.68" diameter 1.0-1.5C[Hp] 22.3" length x 2.68" diameter Motor Weights (MS 3 & MSE 3): 0.33-0.50A[Hp] 6.0 lbs 0.50-0.75B[Hp] 7.1 lbs 1.0-1.5C[Hp] 8.2 lbs Pump End Dimensions: Pump Diameter: 2.68" Pump Diameter, incl. cable guard: 2.91" Pump End Dimensions(min. and max.): 5SQ/SQE 10.6" to 18.0" 10SQ/SQE 10.6" to 16.9" 15SQ/SQE 10.6" to 16.9" 22SQ/SQE 10.6" to 16.9" 30SQ/SQE 10.6" to 13.7" Pump End Weights (min. and max.): All SQ/SQE Models 2.2 lbs to 3.5 lbs Well Diameter (minimum): 3" Installation Depth (Maximum): 500 feet, below static water level SQ/SQE Technical Data
  • 35. Technical Data 35 Description Product no. CU300 Status Box 96422776 No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm On Off CU 300 GRUNDFOS Description Product no. 5-15 SQE 96022968 (Includes CU300, pressure transducer & .5 gpm flow switch) 22-30 SQE 96022971 (Includes CU300, pressure transducer & 1 gpm flow switch) Constant Pressure Kit Description Product no. 5-15 SQE .5 GPM 96022967 22-30 SQE 1 GPM 96022970 Flow Switch Description Product no. Pressure Transducer 0-90 psi (0-6 bar) 96026030 Pressure Transducer CU300 Status Box SQ/SQE Accessories Description Product no. 3" Sanitary Well Seal 1B5102 3" Well Seal
  • 36. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 36 SQE - Speed calculation software SQ/SQE - Flow sleeve Description Product no. Flow Sleeve Complete 96037505 Description Product no. The R100 is used for wireless infrared communication with the CU300 6253333 Description Product no. Printer for R100, infrared communication 620480 Type: Hewlett Packard, HP 82240B Paper Roll 620481 Description Version Product no. External potentiometer with cabinet Grundfos potentiometer, SPP1 for wall mounting. Enclosure class: IP 55 655468 Screened cables, 4-wire cable, max. length of cable: 100m Description Product no. Speed calculation program (Windows95) including: • PC Tool SQE speed calculation, two diskettes 96426840 • Operating manual SQ/SQE Accessories
  • 40. SQ/SQE Data CAPACITY (GPM) HEAD(FEET) 40 Grundfos Pumps Corporation Customer Service Centers: Phone: Fax: Canada: Mexico: • 3131 N. Business Park Avenue • Fresno, CA 93727 Allentown, PA • Fresno, CA (559) 292-8000 • (559) 291-1357 Oakville, Ontario • Apodaca, N.L. Visit our website at www.us.grundfos.com ISO 9001 REGISTERED L-SQ-TL-002 Rev.7/99 PRINTED IN USA