SlideShare a Scribd company logo
1 of 1
Download to read offline
Date
Client
ProjectPhase
Revision 0
Architectural Design
& Draughting Services
Date
1:50A1
Project
Tel : 01904 762691
Mobile: 07913 295205
Email: info@addsyork.co.uk
Web: www.addsyork.co.uk
All Dimensions in millimetres unless
otherwise stated
This drawing must not be re-issued,
loaned or copied without the
permission of ADDS
Tel: 01904 762691
Drawn By
Paul Roberts
Drawing
Rev
Drawing Number
Construction
February 2015
Mr & Mrs I Bancroft
Corner Cottage
5A Main Street
Wilberfoss
York YO41 5NP
15-106
Two storey side extension with
attached Garage
ProposedGround&FirstFloorPlan
Sheet 3 of 6
750
750
750
Ensuite
Cupbd
750
750
Bathroom
750
down
Cupbd
removewall
Remove door
& block up
750
750
750
750
750
Master Bedroom
Store
Bedroom
2
Bedroom 3
Bedroom 4
Proposed First Floor Plan
750
WC
Roof Void
2430
2635
5190
3415
3150
2645
Bedroom 5
3200
New stud wall
New stud wall
Newstudwall
New stud wall
LINTELS
Lintel No. LengthType
Catnic steel lintels to be used above all openings.
Sizes as indicated and shown in the table below. Ensure all
lintels are installed in strict accordance with the manufacturers
recommendations, have dpc fitted above and have a min.
150mm end bearing.
CN71A 1200mm
CG90/100 1950mm
CG90/100 1200mm
1, 2
New stud wall
New Velux roof window
Size Code C02
550x780
Position to be determined on-site
Make new
opening
900wide
New window
Size 1200 x 1050
Remove window
& block up with
cavity wall
construction
This window to be centred
in-line with window opening
below
New window
Size 1200 x 1050
opaque glazing
This window to be centred
in-line with Garage Door
opening below
New window
Size 1200 x 1050
12101210 12102353 2353
700830
Fit mechanical extract ventilation
fan to Ensuite capable of extracting
at least 30 l/sec. and achieving a
rate of at least 3 air changes per
hour. Ventilation to comply with
recommendations of Approved
Document F1 of the Building
Regulations
It is the responsibility of the
contractor to discuss with the client
the exact location and make/type
of fittings required for the new
Ensuite
EW
EW
EMERGENCY EGRESS WINDOWS
All windows marked are to be suitable for
escape purpose and must have a clear
opening of not less than 0.33m2 and have a
minimum opening width of 450mm min. and a
minimum opening height of 750mm min.
Bottom of opening to be 600mm min. and
1100mm max. above floor level. Window to
have non-locking ironmongery.
EW
EW
EW
smoke detectorsmoke detector
Fit mechanical extract ventilation
fan to WC capable of extracting
at least 30 l/sec. and achieving a
rate of at least 3 air changes per
hour, and may be operated
intermittently with 15 mins overun.
Ventilation to comply with
recommendations of Approved
Document F1 of the Building
Regulations
All smoke
detectors to be
mains operated
and interlinked
New
door
New
door
New
door
New
door
New
door
New
door
750
smoke detectorsmoke detector
Ensuite
Dressing
FD30s
EW
1210
This edge to line up with edge
of Door opening below
New window
Size 1200 x 1050
New SVP
New stud wall
TV
TV
Water tank
above
Before removing wall check out
support for water tank above
and strengthen if required
DO NOT SCALE DRAWING - WORK TO FIGURED DIMENSIONS IN ALL CASES
750 75
0
750
Lounge
Dining Room
Kitchen
Lobby
Porch
up
New patio door
Fridge/Freezer
Proposed Ground Floor Plan
750
WC
750
750
Cupbd
2525
Utility
91024402440
5790
(sameasexistingGaragelength)
Re-use existing
Garage window
675
New window & door
1585
Re-use existing
Garage window
2015 910910
New window
Size 900 x 750
1340
New window
Size 1200 x 1050
Re-use existing timber lintel above
garage door openings
(to be structurally verified by Engineer)
2515
300
2762300
Garage Garage
1
2 3 4
5
250900
Remove section of
masonary wall
New
door
New
door
Breakfast Room
Remove stud wall
215
Ext. light with PIR
Ext. light with PIR
ExtentofexistingGarage
Ext. light with PIR
high
Double 13A socket
Light switch
Power supply for
Garage Door
Study
1625 1600
Light (to clients choice) TV
high
vent
Check integrity of floor above
on-site before removal
910665 2450 440 2450 665 1210 553
Ext. light with PIR
New boiler
location
New IC
Exist. gully
Exist. IC
Exist. IC
New foul water pipe
Connect new gully for grey water
waste to main foul water drains. To
be determined on site and
approved by the LA Building
Inspector
IMPORTANT NOTE:
Prior to removal of any walls to form openings, investigation must
be made on site to ascertain the requirements for structural
support above the openings. Prior to any work being carried out
consultation must be made with ADDS and the Local Authority
Building Inspector. All work is to be in accordance with the current
Building Regulations and approved on site by the Local Authority
Building Inspector.
smoke detectorsmoke detector
smoke detectorsmoke detector
EW
Heat Detect.
Heat detector to
be interlinked into
new smoke
detection system
Fit mechanical extract ventilation
fan to Kitchen capable of
extracting at least 60 l/sec. or 30
l/sec. cooker hood. Ventilation to
comply with recommendations of
Approved Document F1 of the
Building Regulations
All smoke
detectors to be
mains operated
and interlinked
FD30s
1565
Ensure min. 100mm step
down to garage
Setting out of proposed extension
is to suit 215 x 102 x 65 bricks with
10mm mortar joints
TV aerial pointTV
24001115
Tallcupboards
750
Ext. light with PIR
PS1
PS2
BEAMA
span=2550
Build in cupboards
to clients choice
Beam & Padstone details
For full details see Engineeers Report
This drawing to be read in
conjunction with Structural Engineers
detail and calculations
Beam A
Newblockwall
3623
3415
TV
EW
1210
New window
Size 1200 x 1050
This window to be centred
in-line with Patio Door
opening below
300
553
Build solid
brickwork pier
8001022
6
16501465
4, 6
7
8
9
10
11
12
13
3, 5, 7, 9, 12, 13
CG90/100 1500mm
CN102 1200mm
CG90/100 2700mm
10
11
8, 9
BEAM B
span = 2450 span = 2450
BEAM C
Beam B
PS3 PS4
PS5
PS6
Padstones
Contractor to check beam
lengths on site before ordering
steelwork
PS 1
PS 2
300 x 100 x 145 cut from Naylor R6 Lintel
300 x 100 x 145 cut from Naylor R6 Lintel
Beam C
300 x 100 x 145 cut from Naylor R6 Lintel
300 x 100 x 145 cut from Naylor R6 Lintel
PS 3
PS 4
STRUCTURAL STEELWORK (Fire protection)
Exposed structural steelwork to achieve half hour fire resistance
through encasing with 2 layers of 12.5mm plasterboard.
NOTES:
1. All steel to be grade S275JR or S355JR
2. All steel to be cleaned to SA2 & shop painted with 2 coats HBZP
primer to a total DFT of 150 microns
3. Steel beams to be site painted with 2 coats of bituminous paint
before being installed
4. All concrete to padstones to be grade C30
5. Beam bearings as shown on Engineers Report
6. Site measure all clear opening widths before fabricating
steelwork
7. All propping, needling & temporary works by building contractor
300 x 100 x 145 cut from Naylor R6 Lintel
300 x 100 x 145 cut from Naylor R6 Lintel
PS 5
PS 6
New door
30min. fire
rated &
surround.
Exterior grade
New door
30min. fire
rated &
surround.
Exterior grade
mains water stopcock
Fit outside tapNew
gully
New window
Size 900 x 1050
New SVP
Connection to existing foul
water drainage system is to be
determined on site and
approved by the LA Building
Inspector
Fit mechanical extract ventilation
fan to Utility Room capable of
extracting at least 30 l/sec. and
achieving a rate of at least 3 air
changes per hour. Ventilation to
comply with recommendations of
Approved Document F1 of the
Building Regulations
It is the responsibility of the
contractor to discuss with the
client the exact location and
make/type of fittings required for
the new Utility
Location of new SVP to be
determined on-site and
approved by the LA Building
inspector
7000wideraft
2975 wide raft
New raft foundation
over this area. See
separate Engineers
detail
127 x 76 x 13 UB x 2750mm long
152 x 89 x 16 UB x 2650mm long
178 x 102 x 19 UB x 2650mm long
Remove existing window and
fit Patio Door set to match
existing Dining Room
Ensure continuous cavity
between new and existing
structure
Ensure continuous cavity
between new and existing
structure
Ensure continuous cavity
between new and existing
structure
Ensure continuous cavity
between new and existing
structure
This wall

More Related Content

What's hot

NMohamed_PortfolioExtract
NMohamed_PortfolioExtractNMohamed_PortfolioExtract
NMohamed_PortfolioExtractNazima Mohamed
 
Centre for the Creative Arts and Media (CCAM) | GMIT General Arrangment Drawings
Centre for the Creative Arts and Media (CCAM) | GMIT General Arrangment DrawingsCentre for the Creative Arts and Media (CCAM) | GMIT General Arrangment Drawings
Centre for the Creative Arts and Media (CCAM) | GMIT General Arrangment DrawingsJonathan Flanagan
 
India’s !st & only Hollywood benchmarked studio facility
India’s !st & only Hollywood benchmarked studio facilityIndia’s !st & only Hollywood benchmarked studio facility
India’s !st & only Hollywood benchmarked studio facilityarchana jhangiani
 
Chobe River College School Hall + Master Site Plan
Chobe River College School Hall + Master Site PlanChobe River College School Hall + Master Site Plan
Chobe River College School Hall + Master Site PlanGrant Hepburn
 
Final year Revit project
Final year Revit projectFinal year Revit project
Final year Revit projectMark Thornton
 
Residential house project sample, WD drawings, NSW
Residential house project sample, WD drawings, NSWResidential house project sample, WD drawings, NSW
Residential house project sample, WD drawings, NSWAlexeyRyabchenko
 

What's hot (14)

Pearce avenue
Pearce avenuePearce avenue
Pearce avenue
 
NMohamed_PortfolioExtract
NMohamed_PortfolioExtractNMohamed_PortfolioExtract
NMohamed_PortfolioExtract
 
Demo Mansion sheet plans
Demo Mansion sheet plansDemo Mansion sheet plans
Demo Mansion sheet plans
 
Go For Broke Arch A-2
Go For Broke Arch A-2Go For Broke Arch A-2
Go For Broke Arch A-2
 
Centre for the Creative Arts and Media (CCAM) | GMIT General Arrangment Drawings
Centre for the Creative Arts and Media (CCAM) | GMIT General Arrangment DrawingsCentre for the Creative Arts and Media (CCAM) | GMIT General Arrangment Drawings
Centre for the Creative Arts and Media (CCAM) | GMIT General Arrangment Drawings
 
2 nd floor plan (2)
2 nd floor plan (2)2 nd floor plan (2)
2 nd floor plan (2)
 
Studiowork submissions
Studiowork submissionsStudiowork submissions
Studiowork submissions
 
Greenbanks
GreenbanksGreenbanks
Greenbanks
 
India’s !st & only Hollywood benchmarked studio facility
India’s !st & only Hollywood benchmarked studio facilityIndia’s !st & only Hollywood benchmarked studio facility
India’s !st & only Hollywood benchmarked studio facility
 
Chobe River College School Hall + Master Site Plan
Chobe River College School Hall + Master Site PlanChobe River College School Hall + Master Site Plan
Chobe River College School Hall + Master Site Plan
 
Final year Revit project
Final year Revit projectFinal year Revit project
Final year Revit project
 
Residential house project sample, WD drawings, NSW
Residential house project sample, WD drawings, NSWResidential house project sample, WD drawings, NSW
Residential house project sample, WD drawings, NSW
 
Portfolio PDF
Portfolio PDFPortfolio PDF
Portfolio PDF
 
Working drawings sample
Working drawings sampleWorking drawings sample
Working drawings sample
 

Similar to 15-106 3

1515-T_Drawings
1515-T_Drawings1515-T_Drawings
1515-T_DrawingsMark Daly
 
Wakefield Avenue Congleton Rev B
Wakefield Avenue Congleton Rev BWakefield Avenue Congleton Rev B
Wakefield Avenue Congleton Rev BKen Crook
 
Proposed Builder's Work Plan for Pub/Restaurant
Proposed Builder's Work Plan for Pub/RestaurantProposed Builder's Work Plan for Pub/Restaurant
Proposed Builder's Work Plan for Pub/Restaurantkristienadana
 
Build Something That Lasts
Build Something That LastsBuild Something That Lasts
Build Something That Lastslharback
 
House Messinger Proposal 2-Sections & Elevations
House Messinger Proposal 2-Sections & ElevationsHouse Messinger Proposal 2-Sections & Elevations
House Messinger Proposal 2-Sections & ElevationsAyla Damon
 
House Messinger Proposal 2-Layouts
House Messinger Proposal 2-LayoutsHouse Messinger Proposal 2-Layouts
House Messinger Proposal 2-LayoutsAyla Damon
 
Mill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONS
Mill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONSMill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONS
Mill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONSSin Byrne
 
011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan011 - Proposed Ground Floor plan
011 - Proposed Ground Floor planDanny Chiverton
 
Leisure Centre
Leisure CentreLeisure Centre
Leisure CentreEdel Fox
 
Construction pdf major project
Construction pdf major projectConstruction pdf major project
Construction pdf major projectYolanda Sewpersad
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residentialgrahamelanders
 
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILSMill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILSSin Byrne
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residentialgrahamelanders
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residentialgrahamelanders
 
BR06 Existing and Proposed Elevation
BR06 Existing and Proposed ElevationBR06 Existing and Proposed Elevation
BR06 Existing and Proposed Elevationsarah ralphs
 
House Plan For Robert Ledwaba
House Plan For Robert LedwabaHouse Plan For Robert Ledwaba
House Plan For Robert LedwabaJan Malesela
 

Similar to 15-106 3 (20)

1515-T_Drawings
1515-T_Drawings1515-T_Drawings
1515-T_Drawings
 
7545 103 final plans as proposed
7545 103 final plans as proposed7545 103 final plans as proposed
7545 103 final plans as proposed
 
Wakefield Avenue Congleton Rev B
Wakefield Avenue Congleton Rev BWakefield Avenue Congleton Rev B
Wakefield Avenue Congleton Rev B
 
Proposed Builder's Work Plan for Pub/Restaurant
Proposed Builder's Work Plan for Pub/RestaurantProposed Builder's Work Plan for Pub/Restaurant
Proposed Builder's Work Plan for Pub/Restaurant
 
Build Something That Lasts
Build Something That LastsBuild Something That Lasts
Build Something That Lasts
 
House Messinger Proposal 2-Sections & Elevations
House Messinger Proposal 2-Sections & ElevationsHouse Messinger Proposal 2-Sections & Elevations
House Messinger Proposal 2-Sections & Elevations
 
House Messinger Proposal 2-Layouts
House Messinger Proposal 2-LayoutsHouse Messinger Proposal 2-Layouts
House Messinger Proposal 2-Layouts
 
Mill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONS
Mill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONSMill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONS
Mill 14-1-15 - Sheet - A107 - PROPOSED EAST & SOUTH ELEVATIONS
 
011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan
 
A2768 103 - floor plans - building regs
A2768 103 - floor plans - building regsA2768 103 - floor plans - building regs
A2768 103 - floor plans - building regs
 
7545 102 final elevations as proposed
7545 102 final elevations as proposed7545 102 final elevations as proposed
7545 102 final elevations as proposed
 
Leisure Centre
Leisure CentreLeisure Centre
Leisure Centre
 
Construction pdf major project
Construction pdf major projectConstruction pdf major project
Construction pdf major project
 
House Carol Submission
House Carol SubmissionHouse Carol Submission
House Carol Submission
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residential
 
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILSMill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
 
BR06 Existing and Proposed Elevation
BR06 Existing and Proposed ElevationBR06 Existing and Proposed Elevation
BR06 Existing and Proposed Elevation
 
House Plan For Robert Ledwaba
House Plan For Robert LedwabaHouse Plan For Robert Ledwaba
House Plan For Robert Ledwaba
 

15-106 3

  • 1. Date Client ProjectPhase Revision 0 Architectural Design & Draughting Services Date 1:50A1 Project Tel : 01904 762691 Mobile: 07913 295205 Email: info@addsyork.co.uk Web: www.addsyork.co.uk All Dimensions in millimetres unless otherwise stated This drawing must not be re-issued, loaned or copied without the permission of ADDS Tel: 01904 762691 Drawn By Paul Roberts Drawing Rev Drawing Number Construction February 2015 Mr & Mrs I Bancroft Corner Cottage 5A Main Street Wilberfoss York YO41 5NP 15-106 Two storey side extension with attached Garage ProposedGround&FirstFloorPlan Sheet 3 of 6 750 750 750 Ensuite Cupbd 750 750 Bathroom 750 down Cupbd removewall Remove door & block up 750 750 750 750 750 Master Bedroom Store Bedroom 2 Bedroom 3 Bedroom 4 Proposed First Floor Plan 750 WC Roof Void 2430 2635 5190 3415 3150 2645 Bedroom 5 3200 New stud wall New stud wall Newstudwall New stud wall LINTELS Lintel No. LengthType Catnic steel lintels to be used above all openings. Sizes as indicated and shown in the table below. Ensure all lintels are installed in strict accordance with the manufacturers recommendations, have dpc fitted above and have a min. 150mm end bearing. CN71A 1200mm CG90/100 1950mm CG90/100 1200mm 1, 2 New stud wall New Velux roof window Size Code C02 550x780 Position to be determined on-site Make new opening 900wide New window Size 1200 x 1050 Remove window & block up with cavity wall construction This window to be centred in-line with window opening below New window Size 1200 x 1050 opaque glazing This window to be centred in-line with Garage Door opening below New window Size 1200 x 1050 12101210 12102353 2353 700830 Fit mechanical extract ventilation fan to Ensuite capable of extracting at least 30 l/sec. and achieving a rate of at least 3 air changes per hour. Ventilation to comply with recommendations of Approved Document F1 of the Building Regulations It is the responsibility of the contractor to discuss with the client the exact location and make/type of fittings required for the new Ensuite EW EW EMERGENCY EGRESS WINDOWS All windows marked are to be suitable for escape purpose and must have a clear opening of not less than 0.33m2 and have a minimum opening width of 450mm min. and a minimum opening height of 750mm min. Bottom of opening to be 600mm min. and 1100mm max. above floor level. Window to have non-locking ironmongery. EW EW EW smoke detectorsmoke detector Fit mechanical extract ventilation fan to WC capable of extracting at least 30 l/sec. and achieving a rate of at least 3 air changes per hour, and may be operated intermittently with 15 mins overun. Ventilation to comply with recommendations of Approved Document F1 of the Building Regulations All smoke detectors to be mains operated and interlinked New door New door New door New door New door New door 750 smoke detectorsmoke detector Ensuite Dressing FD30s EW 1210 This edge to line up with edge of Door opening below New window Size 1200 x 1050 New SVP New stud wall TV TV Water tank above Before removing wall check out support for water tank above and strengthen if required DO NOT SCALE DRAWING - WORK TO FIGURED DIMENSIONS IN ALL CASES 750 75 0 750 Lounge Dining Room Kitchen Lobby Porch up New patio door Fridge/Freezer Proposed Ground Floor Plan 750 WC 750 750 Cupbd 2525 Utility 91024402440 5790 (sameasexistingGaragelength) Re-use existing Garage window 675 New window & door 1585 Re-use existing Garage window 2015 910910 New window Size 900 x 750 1340 New window Size 1200 x 1050 Re-use existing timber lintel above garage door openings (to be structurally verified by Engineer) 2515 300 2762300 Garage Garage 1 2 3 4 5 250900 Remove section of masonary wall New door New door Breakfast Room Remove stud wall 215 Ext. light with PIR Ext. light with PIR ExtentofexistingGarage Ext. light with PIR high Double 13A socket Light switch Power supply for Garage Door Study 1625 1600 Light (to clients choice) TV high vent Check integrity of floor above on-site before removal 910665 2450 440 2450 665 1210 553 Ext. light with PIR New boiler location New IC Exist. gully Exist. IC Exist. IC New foul water pipe Connect new gully for grey water waste to main foul water drains. To be determined on site and approved by the LA Building Inspector IMPORTANT NOTE: Prior to removal of any walls to form openings, investigation must be made on site to ascertain the requirements for structural support above the openings. Prior to any work being carried out consultation must be made with ADDS and the Local Authority Building Inspector. All work is to be in accordance with the current Building Regulations and approved on site by the Local Authority Building Inspector. smoke detectorsmoke detector smoke detectorsmoke detector EW Heat Detect. Heat detector to be interlinked into new smoke detection system Fit mechanical extract ventilation fan to Kitchen capable of extracting at least 60 l/sec. or 30 l/sec. cooker hood. Ventilation to comply with recommendations of Approved Document F1 of the Building Regulations All smoke detectors to be mains operated and interlinked FD30s 1565 Ensure min. 100mm step down to garage Setting out of proposed extension is to suit 215 x 102 x 65 bricks with 10mm mortar joints TV aerial pointTV 24001115 Tallcupboards 750 Ext. light with PIR PS1 PS2 BEAMA span=2550 Build in cupboards to clients choice Beam & Padstone details For full details see Engineeers Report This drawing to be read in conjunction with Structural Engineers detail and calculations Beam A Newblockwall 3623 3415 TV EW 1210 New window Size 1200 x 1050 This window to be centred in-line with Patio Door opening below 300 553 Build solid brickwork pier 8001022 6 16501465 4, 6 7 8 9 10 11 12 13 3, 5, 7, 9, 12, 13 CG90/100 1500mm CN102 1200mm CG90/100 2700mm 10 11 8, 9 BEAM B span = 2450 span = 2450 BEAM C Beam B PS3 PS4 PS5 PS6 Padstones Contractor to check beam lengths on site before ordering steelwork PS 1 PS 2 300 x 100 x 145 cut from Naylor R6 Lintel 300 x 100 x 145 cut from Naylor R6 Lintel Beam C 300 x 100 x 145 cut from Naylor R6 Lintel 300 x 100 x 145 cut from Naylor R6 Lintel PS 3 PS 4 STRUCTURAL STEELWORK (Fire protection) Exposed structural steelwork to achieve half hour fire resistance through encasing with 2 layers of 12.5mm plasterboard. NOTES: 1. All steel to be grade S275JR or S355JR 2. All steel to be cleaned to SA2 & shop painted with 2 coats HBZP primer to a total DFT of 150 microns 3. Steel beams to be site painted with 2 coats of bituminous paint before being installed 4. All concrete to padstones to be grade C30 5. Beam bearings as shown on Engineers Report 6. Site measure all clear opening widths before fabricating steelwork 7. All propping, needling & temporary works by building contractor 300 x 100 x 145 cut from Naylor R6 Lintel 300 x 100 x 145 cut from Naylor R6 Lintel PS 5 PS 6 New door 30min. fire rated & surround. Exterior grade New door 30min. fire rated & surround. Exterior grade mains water stopcock Fit outside tapNew gully New window Size 900 x 1050 New SVP Connection to existing foul water drainage system is to be determined on site and approved by the LA Building Inspector Fit mechanical extract ventilation fan to Utility Room capable of extracting at least 30 l/sec. and achieving a rate of at least 3 air changes per hour. Ventilation to comply with recommendations of Approved Document F1 of the Building Regulations It is the responsibility of the contractor to discuss with the client the exact location and make/type of fittings required for the new Utility Location of new SVP to be determined on-site and approved by the LA Building inspector 7000wideraft 2975 wide raft New raft foundation over this area. See separate Engineers detail 127 x 76 x 13 UB x 2750mm long 152 x 89 x 16 UB x 2650mm long 178 x 102 x 19 UB x 2650mm long Remove existing window and fit Patio Door set to match existing Dining Room Ensure continuous cavity between new and existing structure Ensure continuous cavity between new and existing structure Ensure continuous cavity between new and existing structure Ensure continuous cavity between new and existing structure This wall