VIP ℂall Girls Arekere Bangalore 6378878445 WhatsApp: Me All Time Serviℂe Ava...
8.working casts and dies
1. Working casts and dies
-The working cast is the replica of the
prepared teeth, ridge areas, and the other
parts of the dental arch.
-The accuracy of a cast and die is a
function of completeness and accuracy of
the impression.
2. There are three requirements for
good casts
1.They must be bubble free, especially
along the finish lines of the prepared teeth.
2.All portions of the cast must be distortion
free.
3.The casts must be trimmed to insure
access for carving wax pattern margins.
3. Classification
There are two basic working cast and
die systems
I. Working cast with a Separate die
-Single die for wax coping and margins
-Solid cast for proximal contacts and occlusion
II. Working cast with removable dies
-Retained by pins in a base (stone or plastic(
-One die used for proximal contacts, occlusion and
margins
4. Requirements of Die Material
1.High mechanical strength properties to withstand
handling without being fractured or destroyed.
2.High surface hardness to resist scratching and
abrasion while the wax pattern is being fabricated.
3.Compatible with the impression material.
4.Good color contrast with the other materials so that
the preparation margins can be easily detected.
5.Compatible with the separating medium used.
6.Easily wettable with the wax used.
7.High stability and excellent dimensional accuracy.
5. I. Working cast with a Separate die
-The working cast with a separate die is the simplest
means of fabricating a working cast and die.
Pours 1 and 2 (individual dies) and 3
(working cast).
Pouring an impression for individual dies
and solid cast (multiple pour system).
6. -The procedure require making a sectional cast and a full-arch
cast.
Sectioning the individual dies. The trimmed dies and working cast before
articulation.
8. Disadvantages
1.The wax pattern must be transferred from one cast to
another (from the separate die to the working cast(, so
distortion of the wax pattern may result.
2.The working cast and the sectional cast for the die
can be obtained from separate impressions or by
pouring an elastomeric full-arch impression twice. If a
double pour is utilized, the first cast is used for
fabrication of the die. This technique, unfortunately, can
be used only with elastomeric impressions, since
hydrocolloid is torn and distorted too much to be used
for an accurate second pour.
9. Impression Pouring:
-Hard improved stone (type IV or V( should be used for
fabricating the die and the cast to prevent surface
abrasion when wax pattern is fabricated.
3-kg improved dental stone Hard improved stone
10. -Wash the impression under cold running tap water to
remove mucous and saliva which may cover the
impression, disinfection is then carried out according to
the impression material used.
11. -Follow the manufacturer,s instructions for the correct
water/ratio, which may affect many of the properties of
the set stone, including setting time, porosity, setting
expansion and ultimate strength.
12. -Mix water and stone by
hand with spatula until the
powder is completely wet
then use vacuum.
13. -Using a small instrument to carry stone to the
impression of the prepared tooth, place a small amount
of stone on the side of the impression above the
preparation and vibrate till stone reaches the occlusal
surface of the preparation.
Pouring an impression. To avoid trapping
air, start with a very small amount of stone
14. -Tilt the impression so that the stone flows slowly across the
bottom of the preparation, add stone in small increments. If a
large amount of stone is dropped, air will be trapped, and voids
will result in the cast.
-Build the stone up to a height approximately one inch over the
preparation to allow bulk for an adequate handle of the die.
-To pour a full arch impression, place the tray on the vibrator (do
not rest it on the impression materials(.
-Add small increments of stone to the distal most area of one side
of the impression, slowly raise the distal end of the impression, so
that stone will move mesially flowing from tooth to tooth and filling
each of them from the bottom.
-Add stone and vibrate until all the teeth in the arch are filled.
15. Die Preparation
-The cast from which the die is made, is trimmed on a model
trimmer to remove all excess stone around the prepared tooth.
-The cast is held by the base while cutting it down to form the
handle of the die, the handle of the die should be slightly large in
the diameter than the preparation. Its sides should be parallel or
slightly tapered toward the base, and should be parallel to the long
axis of the tooth, because if not parallel it will be more difficult to
adapt the wax pattern margins. The handle is approximately one
inch long.
-Trim the die gingival to the finish line of the preparation, this area
should be smooth and free from irregularities.
-The contour of the die gingival to the finish line should
approximate that of the root to facilitate good axial contours in the
finished restoration.
16. Trimming the stone representing the free
gingiva to a level lower than the finish line
(trimmed with an acrylic bur).
18. -The die is then painted with a die strengthening material to close
the stone micro porosities, and harden it and decrease scratching.
19. -After the die has been trimmed, the finish line should be
highlighted with a sharp color bright red pencil, this facilitate
carving the margins of the wax pattern.
20. -The preparation area of the die should be painted with
a die relief material to provide space for cement, a relief
of 25 microns is desired, the tooth preparation on the die
is painted within 0.5-1.0 mm of the finish line.
21.
22. II. Working cast with removable dies
Examples
1(Working cast with dowel pins
2(Accutrac system
3(E-Z-Tray system
4(Fix-pin system
5(Model tray (Di-Lok Tray( system
6(MODU system
7(Opti-base system
8(Pindex system
9(Splitfix system
10(Jet-pin system (VIDEO(
11(cross-pin system
12(Zeiser system
23. Requirements of removable Dies
1.The dies must return to their exact original
positions.
2.The dies must remain stable, even when
inverted.
3.The cast containing the dies must be easy to
mount on an articulator.
25. -A dowel pin is positioned over each prepared tooth in
the impression, if the dowel pins are positioned
inaccurately, they may impinge on the margins, weaken
the die, or prevent it from being easily removed from the
cast.
-A number of items can be used for positioning the
dowel pins, anesthetic needles, paper clips and bobby
pins. A dowel is placed between the arms of the bobby
pins, the bobby pin is positioned bucco-lingually across
the impression so that the dowel pin will be entered
directly over the preparation.
26. -Push a straight pin between the arms of bobby pin
and into the impression material on both the buccal
and lingual of each tooth to have a dowel pin placed
over it. Stabilize the dowel in the bobby pin and the
bobby pin itself against the straight pin with sticky wax.
Positioning dowel pins before cast pouring can be accomplished with bobby pins and
sticky wax
27. -Die stone is then poured into the impression, filling the
impression of the teeth and covering the knurled end
“constriction” of the dowel pin.
A) Incorrect technique for pouring an impression.
An air bubble (arrows) will be trapped if two masses
of stone are allowed to meet.
B) Dowel pins must be carefully positioned so
the first pour of stone completely covers the knurled head;
otherwise, the parts will not separate cleanly. However, the
stone should not extend onto the shaft and reduce stability.
A B
28. -Paper clips are set into the stone before it sets, to
provide retention for the base which will be placed later,
these clips should be placed in all parts of the model that
are not to be removable from the completed cast.
Dowel pins are positioned over the
impression with bobby pins.
Paper clips are added to non/removable
parts of the unset first pour to provide
retention for the second pour of stone.
29. -The stone around each dowel is lubricated with a thin
coat of petrolatum to permit easier separation of the die
from the working cast, then pour stone of the complete
base. After complete setting of the stone, remove the
cast from the impression and trim off the excess on a
model trimmer.
The stone around the dowel pins
is lubricated.
A wet paper towel can be used to
fill in the open, center portion of the
impression.
30. -Use sharp knife to remove the spheres of utility wax.
-When the stone is hard and dry, use a saw frame to cut
through the layer of the stone, mesially and distally on
each die, the cuts should taper toward each other
slightly from occlusal to gingival.
Wax at the ends of the dowel pins is
located and removed.
Dies are separated from the rest of
the cast with a fine saw.
31. -Loosen the die gently using an instrument handle.
-Place wax around the tips of the dowels to protect
them from the plaster contamination.
-Soak the cast in the water and mount it on the
articulator, using mounting plaster. After hardening of
the plaster remove the wax covering the tips of the
dowels.
-Trim away any excess stone gingival to finish line, then
mark the finish line with the red pencil.
-Repeat the procedure for each die on the cast.
-Reseat the dies to make certain that they will seat
completely and will be stable.
32. Base of the die is trimmed with an
acrylic bur.
Dies are reseated into the cast.
33. After the casts have been mounted, wax is removed from the
ends of the dowel pins.
34.
35. 2-Pindex system
-The pindex system ( Coltene / whaledent, Mahwah, NJ)
is a reverse drill press is used to create a master cast
with dies that can be removed and replaced repeatedly
with great precision.
-The impression is poured without positioning and
attaching dowel pins. The machine accurately drills
parallel holes from the underside of trimmed cast.
36.
37.
38. Index the cast
1.Glue pins with cianoacrylate cement
-Long pin toward facial
-Short pin toward lingual
-Glue short pins first (better access)
2.Place sleeves on pins (stability of pins)
3.Box and seal cast
4.Apply separating solution
5.Pour second base with yellow stone
39. Section & Trim dies
1.Mark planned saw cuts with a pencil
2.Create removable segments with a saw
-Parallel saw cuts
-Each segment individually removable
3.Using microscope, remove gross stone beyond finish
line with a#7 lab carbide bur in straight handpiece
4.Finish trimming with scalpel or cleoid-discoid under
microscope
40.
41. Die Trimming
1.Remove most of excess stone with # 7 lab carbide bur
with protective eyewear
2.Fine trimming with scalpel or cleoid-discoid carver
3.Margin should be sharp and distinct for access, but it
should not be undermined
4.Uncut tooth beyond finish line should be maintained to
provide proper contours in wax
42.
43.
44. Die preparation
1.Apply die hardener
-Cover die beyond finish lines
-Allow to set for 5 minutes
2.Apply die spacer
-25micron thickness allows space for cement
-Spacer 1 mm from finish line
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68. 3-Di-Lok Tray
-A snap-apart plastic tray with internal orienting
grooves and notches also can be used to
reassemble the working cast and die
69. Armamentarium
1.5OO-ccVac-U-Mixerand vacuum tubing
2.Vibrator
3.Water measure
4.Large and small spatulas
5.Die stone (Silky-Rock,Vel-Mix(
6.Humidor
7.Model trimmer
8.Straight handpiece and pear-shaped acrYlic bur
9.Laboratory knife with no. 25 blade
10.Tanner carver,
11.Colorbrite red pencil
70. Model tray
system
The model tray system
consists of a part plastic
tray, wit internal orienting
grooves and notches. for
mounting in the articulator
are the fixation systems
(magnets, connectors) at
disposal.
71. Impression and tray are filled with
super hard stone and put together
so that the stone is very hard, the model with
the teeth is taken down.
72. Disassembly of the cast
In the center of the base we drill with
a thicker round bur a hole. With a
compressed air nozzle, the cast of
the tray is blown.
A saw cut is made on each side
of the prepared tooth.
73. The dies are broken by a suitable instrument
from the master model
74. to be mounted in the articulator different
retention methods are available: plug-
retention......
........Snapper retention and.......
.......Magnetic retainers
75. Zeiser system
The double expansion in the base and in the
teeth leads to undesirable heights and axial
displacements of the whole model
Portions of impression, which are not required to
be circumcised
At Zeiser model are the original dimensions of
the impression on a dimensionally stable base
plate transfer
76. The impression is leveled and fixed
with silicon putty.
Portions on the master model need
not be shown to be blocked out with
silicone putty.
The transparent plate is used The pin locations and the saw cuts
are determined
77. The socket plate is inserted from below The notches must face up
78. The carrier sheet is
placed together with the
fixed impression
The entire arrangement
......the entire arrangement
inserted into the Zeiser-pin drilling unit
79. The pinholes drilled in the
base
For drilling, press the entire
assembly down quickly
80. Pins are inserted into the base.
With the base plate to check whether the
pins were positioned correctly
81. The impression material is pretreated
.....And poured the full arch
impression with die stone, restricted
to u-shaped arch i.e. with no stone
on the center
82. With one instrument, the base plate
is filled with stone...
….......And then filled to the brim of
kneading silicone with stone
83. The base plate is mounted in the
carrier plate...
......And lowered into the gypsum
slurry, formed by contact with the
kneading silicone
84. The bulging stone is cut away
After 30 minutes, the ring gear and
the socket plate removed
85. The cast is separated from the
impression when set and then
separated from the base
87. The Palatal or lingual side of the
cast base is trimmed with an
arbor band
a gap!!!
88. A precision saw aids sectioning
The Zeiser model can be cut with a
diamond wheel or a fine saw
89. The sectioned cast
The die is trimmed apical to
the finish line with an arbor
band or with an acrylic bur
....and thoroughly cleaned
with a brush from the dust
90. Dies are reseated exactly into the cast
with a key, the magnet plate screwed into the
base plate
the magnet plate is covered with a foil